bidding & contract requirements...1 mcd supply lay-in clg lay-in adjustable bwe with obd...
TRANSCRIPT
BIDDING & CONTRACT REQUIREMENTS Section 00 90 01 – AMENDMENT NUMBER 1
AMENDMENT NUMBER 1 00 90 01-1
ISSUE DATE: 12 JULY 2016
TO: PROSPECTIVE OFFERORS AND PLAN HOLDERS
FROM: h. michael bohnsack ARCHITECTS 600 West Main Street Suite 2 Post office Box 820 Carbondale, Illinois 62901 618 457 5709 Fax 618 457 5638
SUBJECT: AMENDMENT NUMBER 1 TO THE SOLICITATION DOCUMENTS FOR:
RFP NO. AAFES-PL-K-REC-09-001-16-034
CONVERT CHURCH'S CHICKEN TO POPEYES FT. LEONARD WOOD, MISSOURI AAFES PN: 03308-14-000005
The following Amendment is supplemental to the Drawings and Specifications and shall be a part of the Solicitation Documents as per the general provisions of the Contract, including General and Supplementary Conditions and other Division 1 Sections contained within the Project Manual dated 24 June 2016.
Receipt of this Amendment must be acknowledged in accordance with the instructions on the reverse of the amendment (AAFES Form 4400-18). Failure to acknowledge this Amendment on proposal OR returning signed amendment (with proposal) may result in proposal being determined non-responsive.
*****************************************************************************************************************
DRAWINGS:
1. Drawing Sheet D-5.00, Demolition Roof Plan/Reflected Ceiling/Equipment Plan:
Demolition Roof Plan: delete notes 2D1 & 2F1 & hatching related to exhaust fan E-3 & supply fan S-1.
2. Drawing Sheet A-5.00, Roof Plan/Reflected Ceiling Plan:
Roof Plan: Delete roof patching, equipment curbs, & sacrificial membrane related to exhaust fan E-3 & supply fan S-1.
Reflected Ceiling Plan: Delete exhaust hood EH-2. Move 2x4 light troffer west one ceiling grid.
3. Drawing Sheet FS-1.00, Food Service Equipment Plan & Schedule:
Food Service Equipment Plan & Schedule: Delete Item #F71 Exhaust Hood Canopy (EH-2).
4. Drawing Sheet M-1.01, Demolition Plans & Floor Plans - Mechanical:
Floor Plan - Mechanical: Delete Type II oven hood & associated exhaust & make-up fans, ductwork, & wiring.
5. Drawing Sheet E-1.00, Demolition Plans & Floor Plans - Electrical:
Floor Plan - Lighting & Floor Plan - Power: Delete Type II oven hood & associated wiring. Move 2x4 light troffer west one ceiling grid.
6. Drawing Sheet E-1.01, Schedules & Symbols Legend Electrical
Popeyes Equipment Schedule: Delete Item #F71 Exhaust Hood (EH-2).
HVAC Equipment Schedule: Delete E-3 Exhaust Fan & S-1 Supply Fan.
AMENDMENT NUMBER 1 00 90 01-2
Existing Panel LCL Schedule: Revise connected load to be 104496 Watts.
Existing Panel LCR Schedule: Revise 15AMP Exhaust Fan E-3 & Supply Fan S-1 breakers to be 20AMP spares.
*****************************************************************************************************************
The original Solicitation Documents remain in full force and effect, except as modified herein.
Proposals are due as originally advertised.
Sincerely,
h. michael bohnsack ARCHITECTS
END OF AMENDMENT
This Amendment consists of two (2) Pages and attached Revised Drawing Sheets AMT-1/D-5.00, AMT-1/A-5.00, AMT-1/FS-1.00, AMT-1/M-1.01, AMT-1/E-1.00, & AMT-1/E-1.01.
MECHANICALFLOOR PLANS
DEMOLITION PLANS &
AMT-1/M-1.011/8"=1'-0"
EDR
CLC
ARC
HIT
ECTS
ch.
mic
hael
boh
nsac
k
RE-C
600 West Main Street Suite 2 Post Office Box 820Illinois Design Firm License Number 184-002661
h. michael bohnsack A R C H I T E C T S
618 457 5709 Fax 618 457 5638Carbondale, Illinois 62901
LICENSE
SIGNATURE
EXPIRATION DATE
CURRENT DATE
CHANGEECIVRESEGNAHCXEECROFRIA&YMRA
E TM
Ft. Leonard Wood, Missouri
TO POPEYESCONVERT CHURCH'S
12 July 2016
24 June 2016
30 November 2017
ILLINOIS DESIGN FIRM REGISTRATION NO. 184-001152P.O. Box 581 ▪ 413 MainSt ▪ Mt. Vernon, IL [email protected] ▪ (p)618-242-0473 (f)618-242-2330
McCOY and HOWARDCONSULTING ENGINEERS INC.
ENGINEERPROFESSIONALREGISTERED62046964
OF
CHARLES L . CALVERT
I L L I NO I S
CHURCH'SCHICKENKITCHEN
WALK-IN UTILITY
DRIVE-THRU
CHURCH'SCHICKENSERVING
QUEUINGAREA
POPEYE'SBATTER/FRY AREA
WALK-IN
JANITOR
DRIVE-THRU
POPEYE'SSERVING
QUEUINGAREA
POPEYE'SPREP AREA
SCULLERY
RECEIVING/DRY STORAGE
26x1
4 ESA
12x1
2 EEA
6x5
T
12x5
NOTES (THIS SHEET ONLY):1. REMOVE EXISTING EXHAUST HOOD COMPLETELY INCLUDING ASSOCIATED
CONTROLS AND FIRE SUPPRESSION SYSTEM.
2. REMOVE EXISTING EXHAUST FAN AND CURB COMPLETELY. SEEARCHITECTURAL PLANS FOR PATCHING.
3. REMOVE EXISTING EXHAUST DUCTWORK COMPLETELY.
4. REMOVE EXISTING DIFFUSER/GRILLE COMPLETELY INCLUDING ASSOCIATEDDUCTWORK. TYPICAL.
5. EXISTING ROOFTOP UNIT TO REMAIN. REPLACE BELTS AND PULLEYS ANDBALANCE TO 2400 CFM. REPLACE SECOND STAGE COMPRESSOR. CHARGESYSTEMS WITH R-410A.
6. REMOVE EXISTING SUPPLY FAN AND CURB COMPLETELY. SEE ARCHITECTURALPLANS FOR PATCHING.
7. INSTALL HOOD SUPPRESSION SYSTEM PULL STATION. LOCATE IN ANACCESSIBLE LOCATION BETWEEN 42" AND 48" AFF IN EGRESS PATH NOCLOSER THAN 10 LF OR FURTHER THAN 20 LF FROM HOOD. MARK WITH REDSIGN WITH WHITE LETTERING STATING "CHARLEYS HOOD".
8. INSTALL HOOD SUPPRESSION CYLINDERS TIGHT TO CEILING.
9. INSTALL 7x10 BLACK STEEL EA DUCT UP THRU ROOF, PER NFPA 96. TRANSITIONTO 16x16 FAN CONNECTION IN CURB. FLASH IN ACCORDANCE WITH EXISTINGROOF WARRANTY.
10. INSTALL NEW FAN ON NEW CURB. FLASH IN ACCORDANCE WITH EXISTINGROOF WARRANTY. SEE ARCHITECTURAL PLANS.
11. INSTALL NEW MAKE-UP AIR UNIT ON NEW ROOF CURB. FLASH IN ACCORDANCEWITH EXISTING ROOF WARRANTY. SEE ARCHITECTURAL PLANS.
12. REMOVE EXISTING DUCTWORK AS INDICATED. CAP MAINS AIRTIGHT.
13. EXISTING DIFFUSER/GRILLE TO REMAIN.
14. REMOVE EXISTING CONDENSER FOR ICE MACHINE COMPLETELY, INCLUDINGALL ASSOCIATED PIPING AND PIPE CURB. SEE ARCHITECTURAL PLANS FORPATCHING.
15. EXISTING FLY FAN TO REMAIN. REMOVE AND RE-INSTALL AS NEEDED FOR G.C.WORK.
16. EXISTING EXHAUST FAN TO REMAIN.
17. EXISTING THERMOSTAT TO BE RELOCATED. SEE NEW WORK PLAN FOR NEWLOCATION.
18. INSTALL NEW PIPE CURB ON EXISTING ROOF. FLASH IN ACCORDANCE WITHEXISTING ROOF WARRANTY.
19. INSTALL NEW CONDENSER FOR ICE MACHINE ON NEW SUPPORT RAILS. FLASHIN ACCORDANCE WITH EXISTING ROOF WARRANTY.
20. INSTALL REFRIGERANT LIQUID AND HOT GAS PIPING FROM ICE MACHINE TOCONDENSER IN COMPLIANCE WITH EQUIPMENT MANUFACTURERSREQUIREMENTS AND RECOMMENDATIONS
21. INSTALL NEW THERMOSTAT AND HUMIDITY SENSOR FOR MUA-1.
22. MAKE-UP AIR DUCT CONNECTION TO SUPPLY PLENUM. TYPICAL OF 2.
XX
THE CONTRACTOR SHALL VISIT THE JOB SITE BEFORE BIDDING TO ACQUAINT HIMSELF WITHTHE CONDITIONS UNDER WHICH THE WORK MUST BE CARRIED OUT.
MAXIMUM LENGTH OF ALL FLEXIBLE DUCTWORK SHALL BE 6'-0".
ALL DUCTWORK EQUIPMENT, ETC. SHALL BE SUPPORTED FROM STRUCTURAL SUPPORTSYSTEM. NOTHING SHALL BE HUNG FROM ROOF DECK OR CEILING.
SEE REFLECTED CEILING PLANS ON ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OFCEILING GRILLES, REGISTERS AND DIFFUSERS.
KEEP ALL EQUIPMENT SERVICE AREAS CLEAR OF ALL ELECTRICAL CONDUITS, CONTROLWIRING, DUCTWORK, WATER PIPING, ETC. SO AS NOT TO HINDER SERVICE ACCESS TOEQUIPMENT FOR MAINTENANCE AND REPAIR.
COORDINATE LOCATION OF ALL DUCTWORK WITH EXISTING CONDITIONS BEFORE FABRICATIONTO AVOID INTERFERENCES.
EXHAUST DUCT WORK SHALL COMPLY WITH NFPA-96 AND INTERNATIONAL MECHANICAL CODE
AFAI INDICATES EQUIPMENT FURNISHED AND INSTALLED BY THE ARMY AIR FORCE EXCHANGESERVICE. CONTRACTOR SHALL PROVIDE ALL NECESSARY ROUGH-IN AND CONNECTIONS TOEQUIPMENT REQUIRING SAME.
AFCI INDICATES EQUIPMENT FURNISHED BY THE ARMY AIR FORCE EXCHANGE SERVICEINSTALLED BY THE CONTRACTOR. INSTALLATION SHALL BE IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS.
ICE MACHINE RL AND RHG PIPING SHALL BE PROVIDED BY CONTRACTOR AND SHALL BE TYPE LOR ACR COPPER WITH BRAZED JOINTS AND 12" THICK ELASTOMERIC INSULATION ON BOTHLINES. SIZE LINES IN COMPLIANCE WITH AFCI ICE MACHINE INSTRUCTIONS.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
CONDENSATE DRAINREFRIGERANT LIQUIDREFRIGERANT SUCTIONELBOW TURNED UPELBOW TURNED DOWNTEE - 45° BOTTOM OUTLETTEE - 45° TOP OUTLETUNION OR FLANGESUPPLY AIR DUCTWORK (SA)RETURN, EXHAUST, OR OUTDOOR AIR DUCTWORK (RA, EA, OA)SUPPLYRETURN OR EXHAUSTINCLINE RISE (IN DIRECTION OF LFOW)INCLINE DROP (IN DIRECTION OF FLOW)FLEXIBLE DUCTWORKFLEXIBLE DUCT CONNECTIONFIRE DAMPERVOLUME DAMPERACCESS DOOR IN DUCTWORKSECURITY GRILLEACCESS PANEL IN BUILDING CONSTRUCTION - SIZEADJUSTABLE VOLUME EXTRACTORSPLITTER DAMPERTURNING VANESTHERMOSTAT - MOUNT 48" AFF, G INDICATES GAURD, N INDICATES NIGHTGRILLE OR DIFFUSER SYMBOL - SEE SCHEDULE, THROAT SIZE INDICATEDEQUIPMENT DESIGNATION - SEE SCHEDULEDOOR GRILLE AND SIZEDOOR UNDERCUTMOTORIZED DAMPERNEW CONNECTION TO EXISTINGHOOD FIRE SUPPRESSION PULL STATION
MD
DUC
T
2
18x12DG
AHU-1
FD
VD
AP18x18
AD
SG
D
R
12x12
12x12
D
RSRL
FRAMEMOUNTING
B.W.E. INDICATES BAKED WHITE ENAMEL FINISH.
FLANGEIN. x IN.
DUCT
AC = ADAPTER CURB, WD = WEATHERPROOF DRIVE COVER, IC = INTEGRAL CURB CAP AND PLENUM ASSEMBLY, IB = INLET BOX, CT = PROTECTIVE COATINGDS = DISCONNECT SWITCH, BS = BIRDSCREEN, BD = BACKDRAFT DAMPER, UL = UL CLASS 762, HK = HINGING KIT,EDS = NEMA 3R DISCONNECT SWITCH, AD = ACCESS DOORMD = MOTOR OPERATED DAMPER, PC = PREFAB ALUM. 12" HIGH ROOF CURB WITH SLOPE TO MATCH ROOF, GT = GREASE TRAP & DRAIN, HD = HORIZ. DISCHARGE
PAINT ALL BARE METAL SURFACES EXPOSED TO VIEW THRU GRILLE, REGISTER OR DIFFUSER WITH FLAT BLACK PAINT.
1 MCD SUPPLY LAY-IN CLG LAY-IN ADJUSTABLE BWE WITH OBD
1.NOTES:
MARK TYPEMODEL NO. CFM
NOTES:
3.2.
MARK
OBD (OPPOSED BLADE DAMPER).
MODEL NO.
GREENHECKCFM
RPMIN WC.
EXT.S.P.
FAN
MODEL NO.
1.NOTES:
MARK TITUSUSE
MOUNTINGLOCATION
MANUFACTURER
SUPPRESSION
WIDTH
DIMENSIONS (IN)
HEIGHT DEPTH
AREASERVED
REMARKS
INTERLOCKDRIVE
TYPEOF
CONTROLOR AHU
HPIN. x IN.SIZE
DAMPER MOTORPHVOLT
REMARKS
PATTERNAIR
FINISH REMARKS
AREA SERVED
SYSTEM
PROVIDE EH-1 WITH 3" BACK STAND-OFF, AND FAN SWITCH WITH PILOT LIGHTS.2. PROVIDE EH-1 WITH FIRE SUPRESSION SYSTEMS COMPLYING WITH NFPA-17A.
HINGED ACCESS DOORS WITH TOOL FREE FASTENERS
FACTORY MOUNTED DISCONNECT SWITCH AND THRU THE BASE ELECTRICAL CONNECTION.
COOLING COIL ENT. AIR DB/WB
MAXIMUM COMPONENT WEIGHT
ALL ROOFTOP UNITS SHALL USE R-410A REFRIGERANT.
COOLING COIL LVG. AIR DB/WB
CAPACITIES BASED ON 98 DEGREE AIR ENTERING CONDENSER.
FACTORY MOUNTED CONTROLS
PROVIDE ROOFTOP UNITS WITH FOLLOWING ACCESSORIES:
HAIL GUARD.
FURNACE ENT. AIR DB
FURNACE LVG. AIR DB
AREA SERVED
MAX. FUSE OR HACR CIRCUIT BREAKER
SENSIBLE COOLING CAPACITY - MBH
EXTERNAL STATIC PRESSURE - IN. W.C.
TOTAL COOLING CAPACITY - MBH
NATURAL GAS INPUT - MBH
COMPRESSOR RATED LOAD AMPS (RLA)INDOOR FAN FULL LOAD AMPS (FLA)
OUTDOOR FAN FULL LOAD AMPS (FLA)
ELECTRICAL SERVICE - VOLTS-PHASE-CYCLE
HEATING OUTPUT - MBH
OPERATING WEIGHT - LBS.
MINIMUM CIRCUIT AMPS
AFUE
TOTAL AIRFLOW - CFMOUTDOOR AIRFLOW - CFM
ENERGY EFFICIENCY RATIO
INDOOR FAN RPM
TRANE MODEL NO.
MARK
1.NOTES:
6.
4.5.
2.3. PROVIDE MERV 8 FILTERS
MUA-1HORIZON B108
160016000.8
18256210910.815012080.0
208-3-6037.14.44.257.490
160093/77
958/58
78
DEDICATED OA
ROOF MOUNTING CURB7. PROVIDE HOT GAS REHEAT COIL AND DEHUMIDIFICATION CONTROLS.8. PROVIDE LOW LEAKAGE OUTSIDE AIR DAMPER. MAX LEAKAGE OF 3 CFM/SF AT 1" WC.
EH-1 2812 BLL I 1870 7x10 18 135 28 ANSUL POPEYES CAPTIVEAIRE
E-1 CUBE-141-5 935 1.25 1404 BELT MANUAL SWITCH 16x16 1/2 120 1 PC,CE,EDS,UL,GT,HK,GG POPEYESE-2 CUBE-141-5 935 1.25 1404 BELT MANUAL SWITCH 16x16 1/2 120 1 PC,CE,EDS,UL,GT,HK,GG POPEYES
E-2E-1
26x1
4 ESA
VD
VD
VDVDMUA-1
T
1
2
3
4
4
4
P
5
6
14
13
13
4
15
16
9109 10
11
SA
SA
SASA
18x16 MAVD
7x10
EA
7x10
EA
CFMX1 800
15 1514"Ø
CFMX1 800
15 1514"Ø
2 50 F RETURN LAY-IN CLG LAY-IN ---- BWE
CFMX2 2000
22 22
CFMX2 2000
22 22
VD
MA
4
1
CFMX1 400
12 1212"Ø
CFMX1 400
12 1212"Ø
CFMX1 650
15 1514"Ø
CFMX1 650
15 1514"Ø
17
P
17
13 2019 18
14
14
7
8
12
T
21
9. PROVIDE THERMOSTAT AND HUMIDISTAT.10. INTERLOCK SUPPLY FAN WITH E-1 AND E-2.
P
EH-1
ELECTRICALFLOOR PLANS
DEMOLITION PLANS &
AMT-1/E-1.001/8"=1'-0"
LDH, RCF
NOTES (THIS SHEET ONLY):
FOOD COURT GENERAL NOTES:
ARC
HIT
ECTS
ch.
mic
hael
boh
nsac
k
RE-C
600 West Main Street Suite 2 Post Office Box 820Illinois Design Firm License Number 184-002661
h. michael bohnsack A R C H I T E C T S
618 457 5709 Fax 618 457 5638Carbondale, Illinois 62901
LICENSE
SIGNATURE
EXPIRATION DATE
CURRENT DATE
CHANGEECIVRESEGNAHCXEECROFRIA&YMRA
E TM
Ft. Leonard Wood, Missouri
TO POPEYESCONVERT CHURCH'S
12 July 2016
24 June 2016
30 November 2017
ILLINOIS DESIGN FIRM REGISTRATION NO. 184-001152P.O. Box 581 ▪ 413 MainSt ▪ Mt. Vernon, IL [email protected] ▪ (p)618-242-0473 (f)618-242-2330
McCOY and HOWARDCONSULTING ENGINEERS INC.
LARRY D . HOWARDLARRY D . HOWARD
I L L I NO I S
ENGINEERPROFESSIONALREGISTERED
6235161
OF
CHURCH'SCHICKENKITCHEN
WALK-IN UTILITY
DRIVE-THRU
CHURCH'SCHICKENSERVING
QUEUINGAREA
CHURCH'SCHICKENKITCHEN
WALK-IN UTILITY
DRIVE-THRU
CHURCH'SCHICKENSERVING
QUEUINGAREA
POPEYE'SBATTER/FRY AREA
WALK-IN
JANITOR
DRIVE-THRU
POPEYE'SSERVING QUEUING
AREA
POPEYE'SPREP AREASCULLERY
RECEIVING/DRY STORAGEPOPEYE'S
BATTER/FRY AREA
WALK-IN
JANITOR
DRIVE-THRU
POPEYE'SSERVING
QUEUINGAREA
POPEYE'SPREP AREA
SCULLERY
RECEIVING/DRY STORAGE
WALK-INSCULLERY POPEYE'S
PREP AREA
QUEUINGAREA
POPEYE'SSERVING
DRIVE-THRUPOPEYE'SBATTER/FRY AREA
RECEIVING/DRY STORAGE
ELECTRICALSYMBOLS LEGEND
SCHEDULES &
AMT-1/E-1.011/8"=1'-0"
RCF, JSS
RCF
ARC
HIT
ECTS
ch.
mic
hael
boh
nsac
k
RE-C
600 West Main Street Suite 2 Post Office Box 820Illinois Design Firm License Number 184-002661
h. michael bohnsack A R C H I T E C T S
618 457 5709 Fax 618 457 5638Carbondale, Illinois 62901
LICENSE
SIGNATURE
EXPIRATION DATE
CURRENT DATE
CHANGEECIVRESEGNAHCXEECROFRIA&YMRA
E TM
Ft. Leonard Wood, Missouri
TO POPEYESCONVERT CHURCH'S
12 July 2016
24 June 2016
30 November 2017
ILLINOIS DESIGN FIRM REGISTRATION NO. 184-001152P.O. Box 581 ▪ 413 MainSt ▪ Mt. Vernon, IL [email protected] ▪ (p)618-242-0473 (f)618-242-2330
McCOY and HOWARDCONSULTING ENGINEERS INC.
LARRY D . HOWARDLARRY D . HOWARD
I L L I NO I S
ENGINEERPROFESSIONALREGISTERED
6235161
OF
POPEYE'S EQUIPMENT SCHEDULE
ITEM DESCRIPTION QTY VOLT PHASE LOADOUTLETHEIGHT
TYPECONNECTION BRANCH CIRCUIT REMARKS
A10.U3 FRYER BATTERY 2 120 1 8.5A 8" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
A31 MARINATOR 1 120 1 3.1A 14" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
A46 BATTER / SIFTER CART 1 120 1 1.6A 24" CORD & PLUG
A47.4 ICE BATTER / SIFTER TABLE 1 120 1 10.0A 14" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
A54 FREEZER, UPRIGHT 1 120 1 9.0A 78" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
B10 CONVECTION OVEN (DOUBLE) 1 208 3 22.0A 22" & 48" DIRECT 3 # 8, # 10 GND, 3/4" C. NOTE 2
B60 REFRIGERATOR, UPRIGHT 1 120 1 6.0A 78" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
B65 BISCUIT HOLDING CABINET 1 120 1 8.3A 46" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
C10.27 REFRIGERATOR, WORKTOP 1 120 1 7.2A 14" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
C20 TOASTER 1 120 1 13.0A 46" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
D20 MICROWAVE OVEN 2 208 1 16.6A 42" & 66" CORD & PLUG 2 # 10, # 12 GND, 3/4" C. NEMA 6-20R RECEPT.
D29 PACKING STATION W/DIPPER WELL 2 208 1 6.0A 24" DIRECT 2 # 10, # 10 GND, 3/4" C.
D40 102" POWERSOAK SINK 1 208 3 26.7A 10" DIRECT 3 # 6, # 8 GND, 1" C. NOTE 2
D70 HOT WATER MACHINE 2 208 1 19.5A 46" DIRECT 2 # 10, # 12 GND, 3/4" C. NOTE 2
DB1 RETHERMALIZER 1 208 1 47.6A 18" DIRECT 2 # 6, # 8 GND, 1" C. NOTE 2
D90 HOLDING CABINET, REACH-IN 1 120 1 14.4A 70" CORD & PLUG 2 # 10, # 12 GND, 3/4" C.
D92 HOLDING CABINET, PASS THRU 2 208 1 13.87A COND.DROPFROM
CLG
CORD & PLUG 2 # 12, # 12 GND, 3/4" C. NEMA 6-20R RECEPT.CONNECT TO PWRSTRIP ON EQUIP.H10-3PD
D93.1 CHICKEN HOLDING UNIT 1 120/208 1 37.5A DIRECT 3 # 8, # 10 GND, 3/4" C. MOUNT OUTLET INH10-3PD. NOTE 2
D94 DEDICATED HOLDING UNIT 1 208 1 30.0A COND.DROPFROM
CLG
CORD & PLUG 3 # 8, # 10 GND, 3/4" C. NEMA L6-30RRECEPT. CONNECT TOPWR STRIP ON EQUIP.H10-3PD. NOTE 2
F15 EXHAUST HOOD DIRECT BUILT -IN FAN & LGTSWITCHES.
F15.1 HEATED HOLDING UNIT, WALL MT. 1 208 1 18.8A 55" DIRECT 3#10, #10 GND, 3/4"C. WIRE TO SWITCH INF15 CONTROL PANEL.NOTE 2
H10-3PD PRODUCTION COUNTER
HEAT LAMP 1 120/208 1 7.5A 12" DIRECT 2 # 12, # 12 GND, 3/4" C.
HOT FOOD WELL 1 208 1 6.0A 12" DIRECT 2 # 12, # 12 GND, 3/4" C.
J40 U/C REFRIGERATOR 1 120 1 4.9A CORD & PLUG 2 # 12, # 12 GND, 3/4" C. MOUNT OUTLET INH10-3PD
KDS KITCHEN DISPLAY SYSTEM 2 120 1 ABV. CLG. CORD & PLUG SEE ARCH ELEVATION
K11 ICE CUBER W/ REMOTE CONDENSER 1 208 3 9.2A 72" DIRECT 3# 12, # 12 GND, 3/4" C. REMOTE CONDENSER1.0A, 200/1
K20 WATER FILTER 1 120 1 1.5A 78" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
K31 SODA DISPENSER 1 120 1 1.5A 46" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
K31A CARBONATOR 1 120 1 1.5A 14" CORD & PLUG 2 # 12, # 12 GND, 3/4" C.
K71 TEA / COFFEE BREWER 1 120/208 1 13.0A 46" DIRECT 3 # 12, # 12 GND, 3/4" C.
M30 SAFE 1 120 1 CORD & PLUG
P20 P.O.S. CASH REGISTER 4 120 1 3.0A 24"U.N.O.
CORD & PLUG 2 # 12, 2# 12 GND, 3/4"C.
PROVIDE BONDED &ISOLATED GND.WIRES
P30 PRINTER 3 120 1 1.5A 24"U.N.O.
CORD & PLUG 2 # 12, 2# 12 GND, 3/4"C.
PROVIDE BONDED &ISOLATED GND.WIRES
Q11 MENU BOARD, 3 PANELS 1 120 1 46" DIRECT 2 # 12, # 12 GND, 3/4" C. NOTE 3
Q12 PRESELL DIGITAL MENUBOARD 1 120 1 DIRECT 2 # 12, # 12 GND, 3/4" C. SEE ARCH ELEVATION
Q20 MENU BOARD, DRIVE-THRU 2 120 1 DIRECT 2 # 12, # 12 GND, 3/4" C. SEE ARCH ELEVATION
Q21 ORDER CONFIRMATION UNIT 1 120 1 DIRECT 2 # 12, # 12 GND, 3/4" C.
Q23 MENU CANOPY 1 120 1 DIRECT 2 # 12, # 12 GND, 3/4" C.
Q24 DIRECTIONAL SIGN 1 120 1 DIRECT 2 # 12, # 12 GND, 3/4" C.
Q25 THANK YOU SIGN 1 120 1 DIRECT 2 # 12, # 12 GND, 3/4" C.