bid request and bid 6006 js s.pdf · and training on the use of new equipment of new pool...
TRANSCRIPT
BID REQUEST AND BID CONDITIONS
BID REQUEST NO.: 20-6006-JS-S STRATEGIC SOURCING SPECIALIST: James E. Shatto
TITLE: POOL FILTRATION SYSTEM REPLACEMENT PHONE NO.: 816-235-1397
ISSUE DATE: 03/06/2020 E-MAIL: [email protected]
RETURN BID NO LATER THAN: 04/16/2020 AT 3:00 PM CENTRAL TIME
MAILING INSTRUCTIONS: Print or type Bid Request No. and Return Due Date on the lower left hand corner of the envelope or package.
Delivered sealed bids must be in UM Procurement Office (School of Ed Building) by the return date and time. Respondents shall also provide an electronic version of their proposal response and the pricing information on a CD or Flash drive included inside the sealed proposal. Faxed or emailed bids will not be accepted!
RETURN BID TO: University of Missouri – Kansas City
School of Education, 615 East 52nd Street
Attn: James E. Shatto
UM Procurement Office, Room 024
Kansas City, MO 64110-2401
You are invited to submit bids on the items or services specified. All bids must be made on this form and shall be subject to the terms and conditions on the
reverse side hereof for furnishing items or services of the description listed below. All deliveries shall be made FOB DESTINATION with freight charges
fully included and prepaid. The seller pays and bears the freight charges.
In compliance with this bid request and subject to all of the terms and conditions thereon, bidder offers and agrees to furnish or deliver the items or perform the
services upon which prices are quoted herein, such items or services to be provided within the number of days indicated after receipt by bidder of University
Purchase Order. Only cash discounts having a period of thirty (30) days or more will be taken into account in determining the lowest bid. Discount time is
compiled from day of delivery and acceptance of items or services or receipt of correct invoice, whichever is later.
The bidder further agrees that the language of this bid document shall govern in the event of a conflict with his/her bid. The bidder further agrees that upon
receipt of an authorized purchase order from the University of Missouri or when a Notice of Award is signed and issued by an authorized official of the
University of Missouri, a binding contract shall exist between the bidder and The Curators of the University of Missouri.
SIGNATURE REQUIRED
DOING BUSINESS AS (DBA) NAME
LEGAL NAME OF ENTITY/INDIVIDUAL FILED WITH IRS FOR THIS TAX ID NO.
MAILING ADDRESS
IRS FORM 1099 MAILING ADDRESS
CITY, STATE, ZIP CODE
CITY, STATE, ZIP CODE
CONTACT PERSON
EMAIL ADDRESS
PHONE NUMBER
FAX NUMBER
TAXPAYER ID NUMBER (TIN)
DISCOUNT TERMS DAYS DELIVERY AFTER RECEIPT OF ORDER
VENDOR TAX FILING TYPE WITH IRS (CHECK ONE) (NOTE: LLC IS NOT A VALID TAX FILING TYPE.)
___ Corporation ___ Individual ___ State/Local Government ___ Partnership ___ Sole Proprietor ___Other ________________
AUTHORIZED SIGNATURE
DATE
PRINTED NAME
TITLE
2
BID REQUEST AND BID CONDITIONS
This Bid Request and Bid is made upon and subject to the following conditions, all of which are accepted by bidder. Upon acceptance by
University, this Bid Request and Bid and the University Purchase Order issued thereon shall constitute the contract for furnishing the items
described in the bid in strict conformity with the contract instruments. 1. No oral explanation in regard to the meaning of the specifications will be made, and no oral interpretation will be given before the award of the contract. If
any person contemplating submitting a bid for this contract is in doubt as to the true meaning of any part of the specifications or any other proposed contract
documents, he may submit to the University a written request for an interpretation thereof. The person submitting the request will be responsible for its prompt
delivery. Any interpretation of the proposed documents will be made by addendum duly issued or delivered to each person receiving a set of such documents.
The University will not be responsible for any other explanation or interpretations of the proposed documents.
2. The University reserves the right to reject any and all bids and to waive any informality in bids.
3. Whenever the name of a manufacturer or vendor is mentioned on the face hereon and words "or equal" do not follow, it shall be deemed that the words "or
equal" shall follow such designation unless the context specifies "no substitution". University assumes that items bid as equal are equal. University reserves the
right to return at the bidder's expense all items that are furnished which are not acceptable as equals to items specified by the Bid Request and Specifications,
and vendor agrees to replace such items with satisfactory items at the original bid price.
4. All items bid shall be new unless otherwise specified by the University.
5. Bidder agrees to unconditionally guarantee all items bid upon against defects in material and workmanship for a period of one year from the date of
acceptance by the University unless otherwise specified.
6. Unless it is so noted on the bid it will be deemed that the article furnished is that designated. If the vendor proposes to furnish an item of a different
manufacturer or vendor other than the one specified on the face hereof, the manufacturer or vendor of the substituted items shall be noted and complete
descriptive literature describing the items to be substituted must accompany the bid.
7. Materials and services furnished the University are not subject to either Federal Excise Taxes or the Missouri Sales Tax. Exemption certificates will be
furnished on request.
8. Prices quoted are to be firm and final and prices shall be stated in units of quantity specified with packing and drayage charges included.
9. Shipments shall be marked as directed on the Purchase Order.
10. C.O.D. shipments will not be accepted. All shipping charges must be PREPAID. No packing or drayage charges will be allowed.
11. The University will not be responsible for articles or services furnished without a Purchase Order.
12. Risk of loss or damage to the goods prior to the time of their receipt and acceptance by the University is upon the vendor.
13. All invoices and correspondence shall show the Purchase Order Number. All invoices must be rendered in duplicate and contain full descriptive
information on items or service furnished. Separate invoices shall be rendered for each order and forwarded to the University.
14. Vendor agrees to defend, protect and save the University harmless from all claims and actions arising out of patent infringement.
15. University reserves the right to cancel all or any part of orders if shipment is not made as promised. Vendor shall notify the University if shipment cannot
be made as promised. Time of proposed delivery must be stated in definite terms in the space provided.
16. The bidder hereby guarantees that no article listed herein is adulterated or misbranded within the meaning of the Federal Food, Drug and Cosmetic Act or
an article which may not, under the provisions of Federal Law, be introduced into interstate commerce.
17. Samples, when required, are to be furnished prior to the date specified for receipt of bids.
18. In case of any doubt or difference of opinion as to the items to be furnished hereunder or the quality thereof, the decision of the UM Chief Procurement
Officer shall be final and binding upon both parties.
19. The University reserves the right to award an order to the lowest aggregate bidder for all items or on an item basis, or a group of like items,
whichever is found to be in the best interest of the University. If a split award is not acceptable to a bidder, it must be stated in the bid response.
20. In awarding the contract, the University may take into consideration the skill, facilities, capacity, experience, ability, responsibility, previous work, the
financial standing of the bidder or bidders; the amount of other work being carried on by the bidder; the quality, efficiency, and construction of the equipment
proposed to be furnished; the period of time within which the equipment is to be furnished and delivered; and the necessity of prompt delivery of the items
herein described. The inability of any bidder to meet the requirement mentioned above may be cause for rejection of his bid.
21. In the event that time and materials are a portion of this bid, the University reserves the right to audit vendor's records concerning this bid.
22. All items or services to be furnished hereunder shall meet all applicable State and Federal requirements of the Occupational Safety and Health Standard.
All alleged violations and deviations from said State and Federal regulations or standards of the items of services to be furnished hereunder, must be set forth
on the Bid Form at the time of submission of the bid. Or if at any later date the items or services contained herein shall not meet all applicable state and federal
requirements after the bidder is awarded the contract hereunder the bidder must notify the Campus Purchasing Manager, immediately by certified mail, return
receipt requested.
23. The University serves from time to time as contractor for the United States Government. Accordingly, the provider of goods and/or services shall
comply with federal laws, rules, and regulations applicable to subcontractors of government contracts including those relating to equal employment
opportunity and affirmative action in the employment of minorities (Executive Order 11246), women (Executive Order 11375), persons with disabilities (29
USC 706 and Executive Order 11758), and certain veterans (38 USC 4212 formerly [2012]) contracting with business concerns with small disadvantaged
business concerns (Publication L. 95-507). Contract clauses required by the Government in such circumstances are incorporated herein by reference.
24. The Curators of the University of Missouri have adopted a policy which is binding upon all employees and departments of the University, and which by
contract shall be binding upon independent contractors and subcontractors with the University, whereby all other things being equal, and when the same can be
secured without additional cost over foreign products, or products of other states, a preference shall be granted in all construction, repair and purchase
contracts, to all products, commodities, materials, supplies and articles mined, grown, produced and manufactured in marketable quantity in the State of
Missouri and to all firms, corporations or individuals doing business as Missouri, firms, corporations, or individuals. By virtue of the foregoing policy,
preferences will be given to materials, products, supplies, or provisions, and all other articles produced, manufactured, mined or grown within the State of
Missouri, and to all firms, corporations or individuals doing business as Missouri firms, corporations or individuals. Each bidder submitting a proposal agrees
to comply with and be bound by the foregoing policy.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
3
NOTICE TO BIDDERS
The University of Missouri (UM) requests bids for the Removal of Old, Furnishing, Delivery, Installation
and Training on the use of New Equipment of NEW POOL FILTRATION SYSTEM per the following for
the UM UMSL Campus in the City of St Louis, MO, 63121, Bid #20-6006-JS-S, which will be received by the undersigned at the office of UM Procurement, University of Missouri-Kansas City Campus, School of Education Building, Room 024, 615 East 52nd Street, Kansas City, MO 64110 until 3:00 p.m., Central Time, on Thursday, April 16, 2020. There will be a Bid Opening for those who wish to attend. (Yes, this bid is for the St Louis Campus; however, bid responses are to be returned to James E. Shatto at his office at the UM Kansas City Campus, UMKC.)
(Please note there is often a 1-2 day delay in final delivery when using the U.S. Postal Service due
to transition into the UMKC campus mail delivery process. Regardless of this, your bid must be
received at the final location by the deadline, no exceptions, so plan accordingly.)
Any subsequent Addenda to this bid can be found at the website shown below. It is the responsibility of the bidders to check the site for any addendums to this bid. https://www.umsystem.edu/ums/fa/procurement/bids Bid Questions and Clarifications shall be directed in writing to James E. Shatto at [email protected]. The University reserves the right to waive any informality in bids and to reject any or all bids.
FOR THE CURATORS OF THE UNIVERSITY OF MISSOURI
By:
James E. Shatto, Strategic Sourcing Specialist
University of Missouri – Kansas City UM Procurement Office School of Education, Room 025 615 East 52nd Street Kansas City, MO 64110-2401 Email: [email protected]
Issue Date: March 6, 2020
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
4
DETAILED SPECIFICATIONS & SCOPE OF WORK
GENERAL
1.1 INTENT
A. The purpose of this bid is to remove existing equipment, purchase and have installed a complete new
filtration and recirculation system for the UMSL swimming pool. It is intended to limit the bidding to a
style of product and company that has a proven history and record of performance.
B. Due to the specialized nature of certain components required for this project, these specifications, in
some instances, refer to various components by trade or manufacturers name.
C. Whenever a proprietary (trade) name is used within this Specification Section, it is used for
informational purposes to describe a standard of required function, dimension, appearance and quality.
References to materials by trade name, make or model number shall not be construed as limiting
competition. All bidders are required to bid on the named manufacturer in the BASE BID. The
Contractor may at his option, elect to bid using the products and/or services of alternate manufacturers
listed as ALTERNATES ON THE BID FORM.
NOTE: All treatment systems proposed MUST be fully compatible and connectible with our
current BESC Technology system!
D. A Mandatory Pre-Bid Conference is scheduled for Thursday, March 19, 2020, 12:30 P.M. Central
Time. It is the intent and desire, by the University, for interested Respondents to understand the Work
Site, culture and campus settings and surroundings at UMSL as well as to clarify any areas of ambiguity
in the request for bid and to provide prospective bidders the opportunity to obtain information necessary
to submit a complete bid.
The conference will be held in the Conference Room at the Recreation and Wellness Center,
Conference Room 1, 11 Grobeman Drive, St Louis, MO 63121.
Interested respondents should respond, indicating their intent to attend the pre-bid conference by
contacting James E. Shatto, Strategic Sourcing Specialist, at [email protected] by Monday, March
16, 2020 at 3:00 PM Central Time.
SPECIAL CONDITIONS
A. Evaluation and Award
UM Procurement will review all bids and award to the lowest responsible and responsive bid
meeting the specifications outlined herein. UM Procurement reserves the right to reject all bids.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
5
Bidders shall hold margin price(s) fixed for up to 30 days from receipt of bids unless extended
based on mutual agreement.
B. Campus Contact/Questions
UM Procurement is the issuing office for this RFB and all subsequent addenda relating to it. UM
Procurement is the sole point of contact regarding all Procurement and contractual matters relating
to the requirements described in this RFB. UM Procurement is the only office authorized to
change, modify, clarify, etc., the specifications, terms, and conditions of this RFB and any
contract(s) awarded as a result of this RFB.
Questions prior to submission of the bid shall be directed in writing to James E. Shatto of the UM
Procurement Office. Questions are to be sent by e-mail to [email protected] . The cutoff date for
questions is Tuesday, March 24, 2020 at 3:00 p.m. Central Time.
C. Delivery
Delivery is essential to the performance of the contract to be awarded hereunder. Bidders shall set
forth in their bid the timeline in which their product will be fully completed and can be delivered in
strict accordance with the specification. If bidder does not set forth their timeline for delivery their
bid may be rejected.
The location of the installation is noted herein. All work is on the campus of the University of
Missouri-St Louis, MO.
All Items will be delivered F.O.B University of Missouri-St Louis campus, Full Freight Allowed.
Co-ordinate all deliveries with University (UMSL) personnel. The quantity of each item to be
delivered shall be specified by University of Missouri Procurement Department or their
representatives. The University will be responsible only for those items the successful bidder has
been requested to deliver by the University of Missouri Procurement Department.
The University reserves the right to return at the bidder’s expense, shipments failing to meet the
specification. Bidders are required to identify their replacement policy/procedure, with their bid
submission, for any concealed damaged identified and for items damaged during installation.
D. Payment
a. Preferred settlement method is through the use of Electronic Accounts Payable solutions.
Payment terms associated with these forms of payment will be issued as net 15 after the date of
invoice. Payment terms associated with settlement by check will be considered to be net 30
days. Cash discounts for prompt payment may be offered but they will not be considered in
determination of award unless specifically stated in the Detailed Specifications and Special
Conditions. The University may withhold payment or make such deductions as may be
necessary to protect the University from loss or damage on account of defective work, claims,
damages, or to pay for repair or correction of equipment or supplies furnished hereunder. The
University may be open to an agreed-upon up-front payment to start the manufacturing process.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
6
Other payment(s) may not be made until satisfactory delivery and acceptance by the University
and receipt of correct invoice have occurred.
b. The successful bidder will make application for payment by furnishing the University with an
original invoice setting forth the quantity and total value of each delivery.
c. Invoices properly prepared and executed by the successful bidder are to be sent to the
University of Missouri-Columbia, MO to the address that will be specified on the University
Purchase Order. All invoices must include Purchase Order Number assigned, if applicable.
E. Performance Bond
When the Contract sum exceeds Fifty Thousand Dollars ($50,000.00), the Contractor shall procure and
furnish a Performance bond and a Payment bond in the form prepared by the Owner, each in the
amount equal to one hundred percent (100%) of the contract sum, as well as adjustments to the
Contract Sum. The Performance Bond shall secure and guarantee Contractor’s faithful performance of
this Contract, including but not limited to Contractor’s obligation to correct defects after final payment
has been made as required by the Contract Documents. The Payment Bond shall secure and guarantee
payment of all persons performing labor on the Project under this Contract and furnishing materials in
connection with this Contract. These Bonds shall be in effect through the duration of the Contract plus
the Guaranty Period as required by the Contract Documents. Prices quoted for the Scope of Work in
this RFB shall include the cost of these Bonds.
F. General Conditions of the Contract for Construction and Prevailing Wage Requirements
See the below link to the UM Facilities Planning and Development website, stating the prevailing wage
guidelines. For immediate reference see the attached UM General Conditions, page GC/35, section 13.6.
In addition, I have included an email from Mr. Butch Garrett, UM Prevailing Wage Coordinator, clarifying
the “new” Prevailing Wage dollar amount.
https://www.umsystem.edu/ums/fa/facilities/prevailing_wage_labor_compliance
Per Mr. Butch Garrett: Our revised General Condition state under 13.6.1, “Wage Rates (If the contract
amount is less than $75,000, the requirements of this section will not apply. Any contract adjustment that
increase the contract above $75,000 will be subject to this section.”
Certified payrolls will not be required. Wage rates paid need to meet state and federal minimum wage, not
our typical prevailing wage schedule.
G. - GENERAL INSURANCE SPECIFICATIONS (medium risk)
Contractor agrees to maintain, on a primary basis and at its sole expense, at all times during the life of any
resulting contract the following insurance coverages, limits, including endorsements described herein. The
requirements contained herein, as well as the University’s review or acceptance of insurance maintained
by Contractor is not intended to and shall not in any manner limit or qualify the liabilities or obligations
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
7
assumed by Contractor under any resulting contract. Coverage to be provided as follows by a carrier with
A.M. Best minimum rating of A- VIII
Commercial General Liability Contractor agrees to maintain Commercial General Liability at a limit of
not less than $2,000,000 Each Occurrence, $5,000,000 Annual Aggregate. Coverage shall not contain any
endorsement(s) excluding nor limiting Product/Completed Operations, Contractual Liability or Cross
Liability.
Contractor may satisfy the minimum liability limits required for Commercial General Liability or Business
Auto Liability under an Umbrella or Excess Liability policy. There is no minimum per occurrence limit of
liability under the Umbrella or Excess Liability; however, the Annual Aggregate limit shall not be less
than the highest “Each Occurrence” limit for either Commercial General Liability or Business Auto
Liability. Contractor agrees to endorse the University as an Additional Insured on the Umbrella or Excess
Liability, unless the Certificate of Insurance state the Umbrella or Excess Liability provides coverage on a
“Follow-Form” basis.
Business Auto Liability Contractor agrees to maintain Business Automobile Liability at a limit not less
than $2,000,000 Each Occurrence. Coverage shall include liability for Owned, Non-Owned & Hired
automobiles. In the event Contractor does not own automobiles, Contractor agrees to maintain coverage
for Hired & Non-Owned Auto Liability, which may be satisfied by way of endorsement to the Commercial
General Liability policy or separate Business Auto Liability policy.
Workers’ Compensation & Employers Liability Contractor agrees to maintain Workers’ Compensation
in accordance with Missouri State Statutes or provide evidence of monopolistic state coverage. Employers
Liability with the following limits: $500,000 each accident, disease each employee and disease policy
limit.
Contract Language
The Curators of the University of Missouri, its officers, employees and agents are to be Additional Insured
with respect to the project to which these insurance requirements pertain. A certificate of insurance
evidencing all coverage required is to be provided at least 10 days prior to the inception date of the
contract between the contractor and the University. Contractor/Party is required to maintain coverages as
stated and required to notify the University of a Carrier Change or cancellation within 2 business days. The
University reserves the right to request a copy of the policy. The University reserves the right to require
higher limits on any contract provided notice of such requirement is stated in the request for proposals for
such contract.
Indemnification
The Contractor agrees to defend, indemnify, and save harmless The Curators of the University of
Missouri, their Officers, Agents, Employees and Volunteers, from and against all loss or expense from any
cause of action arising from the Contractor’s operations. The contractor agrees to investigate, handle,
respond to and provide defense for and defend against any such liability, claims, and demands at the sole
expense of the Contractor or at the option of the University, agrees to pay to or reimburse the University
for the Defense Costs incurred by the University in connection with any such liability claims, or demands.
The parties hereto understand and agree that the University is relying on, and does not waive or intend to
waive by any provision of this Contract, any monetary limitations or any other rights, immunities, and
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
8
protections provided by the State of Missouri, as from time to time amended, or otherwise available to the
University, or its officers, employees, agents or volunteers.
Failure to maintain the required insurance in force may be cause for contract termination. In the event the
Agency/Service fails to maintain and keep in force the required insurance or to obtain coverage from its
subcontractors, the University shall have the right to cancel and terminate the contract without notice.
The insurance required by the provisions of this article is required in the public interest and the University
does not assume and liability for acts of the Agency/Service and/or their employees and/or their
subcontractors in the performance of this contract.
H. PROJECT SUMMARY
1.1 TIME OF COMPLETION
A. The successful bidder shall begin the Work on receipt of notice to proceed with labor and equipment
and materials in-hand, to commence work on-site promptly in accordance with award.
1.2 ACCESS TO SITE
A. General: Contractor shall have limited use of Project site.
B. Use of Site: Limit use of Project site to Work in areas indicated. Do not disturb portions of Project
site beyond areas in which the Work is indicated.
1. Limits: Confine construction operations to the Pool Mechanical Room.
2. Driveways, Walkways and Entrances: Keep driveways loading areas, and entrances serving
premises clear and available to Owner, Owner's employees, and emergency vehicles at all
times. Do not use these areas for parking or for storage of materials.
a. Schedule deliveries to minimize use of driveways and entrances by construction
operations.
b. Schedule deliveries to minimize space and time requirements for storage of materials
and equipment on-site.
C. Condition of Existing Building: Maintain portions of existing building affected by construction
operations throughout construction period. Repair damage caused by construction operations.
1.3 COORDINATION WITH OCCUPANTS
A. Full Owner Occupancy: Owner will occupy site and existing building(s) during entire construction
period. Cooperate with Owner during construction operations to minimize conflicts and facilitate
Owner usage. Perform the Work so as not to interfere with Owner's day-to-day operations. Maintain
existing exits unless otherwise indicated.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
9
1. Maintain access to existing walkways, corridors, and other adjacent occupied or used facilities.
Do not close or obstruct walkways, corridors, or other occupied or used facilities without
written permission from Owner’s representative.
1.4 WORK RESTRICTIONS
A. On-Site Work Hours: 24/7 access, all days and hours to be Coordinate with Owner’s representative.
B. Restricted Substances: Use of tobacco products and other controlled substances on the UMSL
campus is not permitted.
C. Employee Screening: Comply with Owner's requirements for drug and background screening of
Contractor personnel working on Project site.
1. Maintain list of approved screened personnel with Owner's representative.
D. Product Data: Collect information into a single submittal for each element of construction and type of
product or equipment.
E. Shop Drawings: Prepare Project-specific information, drawn accurately to scale. Do not base Shop
Drawings on reproductions of the Contract Documents or standard printed data unless submittal
based on Architect's digital data drawing files is otherwise permitted.
TEMPORARY FACILITIES AND CONTROLS
1.5 SUMMARY
A. Section includes requirements for temporary utilities, support facilities, and security and protection
facilities.
1.6 USE CHARGES
A. Electric Power Service from Existing System: Electric power from Owner's existing system is
available for use without metering and without payment of use charges. Provide connections and
extensions of services as required for construction operations.
1.7 PROJECT CONDITIONS
A. Temporary Use of Permanent Facilities: Engage Installer of each permanent service to assume
responsibility for operation, maintenance, and protection of each permanent service during its use as
a construction facility before Owner's acceptance, regardless of previously assigned responsibilities.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
10
1.8 TEMPORARY UTILITY INSTALLATION
A. Sanitary Facilities:
1. Toilets: Use of Owner's existing toilet facilities will be permitted, as long as facilities are
cleaned and maintained in a condition acceptable to Owner. At Substantial Completion, restore
these facilities to condition existing before initial use.
B. Isolation of Work Areas in Occupied Facilities: Prevent dust, fumes, and odors from entering
occupied areas.
C. Electric Power Service: Connect to Owner's existing electric power service. Coordinate with
Owner’s representative on locations of outlets with adequate power for equipment, which will not
overtax Owner’s electrical infrastructure.
1.9 SUPPORT FACILITIES INSTALLATION
A. Parking: Use designated areas of Owner's existing parking areas for construction personnel.
Owner’s representative will provide parking tags for bidder’s vehicles.
B. Waste Disposal Facilities: Provide waste-collection containers in sizes adequate to handle waste from
construction operations. Comply with Owner requirements.
EXECUTION
1.10 SUMMARY
A. Section includes general administrative and procedural requirements governing execution of the
Work including, but not limited to, the following:
1. Construction layout.
2. Installation of the Work.
3. Progress cleaning.
4. Protection of installed construction.
1.11 QUALITY ASSURANCE
A. Manufacturer's Installation Instructions: Obtain and maintain on-site manufacturer's written
recommendations and instructions for installation of products and equipment.
1.12 CONSTRUCTION LAYOUT
A. Verification: Before proceeding to lay out the Work, verify layout information with the UMSL
contact personnel. If discrepancies are discovered, notify UMSL personnel promptly.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
11
1.13 INSTALLATION
A. Comply with manufacturer's written instructions and recommendations for installing products and
equipment in applications indicated.
B. Install products at the time and under conditions that will ensure the best possible results. Maintain
conditions required for product performance until completion.
C. Repair or remove and replace damaged, defective, or nonconforming Work.
1.14 PROGRESS CLEANING
A. General: Clean Project site and work areas daily, including common areas. Enforce requirements
strictly. Dispose of materials lawfully.
1. Comply with requirements in NFPA 241 for removal of combustible waste materials and
debris.
2. Do not hold waste materials more than seven days during normal weather or three days if the
temperature is expected to rise above 80 deg F.
3. Containerize hazardous and unsanitary waste materials separately from other waste. Mark
containers appropriately and dispose of legally, according to regulations.
a. Use containers intended for holding waste materials of type to be stored.
B. Site: Maintain Project site free of waste materials and debris.
C. Work Areas: Clean areas where work is in progress to the level of cleanliness necessary for proper
execution of the Work.
1. Remove liquid spills promptly.
2. Where dust would impair proper execution of the Work, broom-clean or vacuum the entire
work area, as appropriate.
D. Waste Disposal: Do not bury or burn waste materials on-site. Do not wash waste materials down
sewers or into waterways.
E. During handling and installation, clean and protect construction in progress and adjoining materials
already in place.
F. Clean and provide maintenance on completed construction as frequently as necessary through the
remainder of the construction period.
G. Limiting Exposures: Supervise construction operations to ensure that no part of the construction,
completed or in progress, is subject to harmful, dangerous, damaging, or otherwise deleterious
exposure during the construction period.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
12
1.15 PROTECTION OF INSTALLED CONSTRUCTION
A. Provide final protection and maintain conditions that ensure installed Work is without damage or
deterioration at time of completion.
B. Protection of Existing Items: Provide protection and ensure that existing items to remain undisturbed
by construction are maintained in condition that existed at commencement of the Work.
PART 2 - CLOSEOUT PROCEDURES
2.1 SUMMARY
A. Section includes administrative and procedural requirements for contract closeout, including, but not
limited to, the following:
1. Final cleaning.
2. Repair of the Work.
3. Training University personnel on the use of the equipment
2.2 FINAL CLEANING
A. General: Perform final cleaning. Conduct cleaning and waste-removal operations to comply with
local laws and ordinances and Federal and local environmental and antipollution regulations.
B. Cleaning: Employ experienced workers for final cleaning. Clean each surface or unit to condition
expected in an average commercial building cleaning and maintenance program. Comply with
manufacturer's written instructions.
1. Complete the following cleaning operations before requesting inspection for completion:
a. Remove tools, construction equipment, machinery, and surplus material from Project
site.
b. Leave Project clean and ready for occupancy.
2.3 REPAIR OF THE WORK
A. Complete repair and restoration operations before requesting inspection for determination of
Substantial Completion.
B. Repair, or remove and replace, defective construction. Repairing includes replacing defective parts,
refinishing damaged surfaces, touching up with matching materials, and properly adjusting operating
equipment. Where damaged or worn items cannot be repaired or restored, provide replacements.
Remove and replace operating components that cannot be repaired. Restore damaged construction
and permanent facilities used during construction to specified condition.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
13
1. Touch up and otherwise repair and restore marred or exposed finishes and surfaces. Replace
finishes and surfaces that that already show evidence of repair or restoration.
2.4 TRAINING UNIVERSITY PERSONNEL ON THE USE OF THE EQUIPMENT
A. The successful supplier shall arrange for and provide training of University Personnel on the use of
the newly installed equipment. The cost of this training shall be included in the overall price of this
project as submitted by the supplier.
SPECIFICATIONS AND ADDITIONAL REQUIREMENTS
1.2 ALTERNATES
A. Other treatment systems will be considered only if a complete set of drawings and specifications
detailing such equipment as it pertains to this project are submitted for evaluation ten (10) days prior to
the bid date. The submission should include a list of five (5) operating installations within a reasonable
distance of the jobsite. List should include the names and telephone numbers of the operating personnel.
The technical contents of the submittal shall include hydraulic calculations, equipment fabrication
details, filter room layout in plan and elevation views, warranties, installation and operating instructions.
NOTE: This information must be submitted by a bidding contractor. Submittals will not be
considered if provided directly by the alternate equipment manufacturer.
NOTE: Other treatment systems MUST be fully compatible and connectible with our current
BESC Technology system!
B. Alternates meeting the terms and conditions of the bidding documents will be acknowledged prior to
bidding by addendum. No alternates will be considered after the bid.
C. For any and all alternates approved in accordance with the above conditions, state the amount to be
DEDUCTED from the BASE BID if an alternate filtration system is being offered. No provision has
been or will be made for ADDITIVE bids.
1.3 SUBSTITUTIONS
No substitutions will be considered unless the specified product becomes unavailable due to no fault of
the Contractor.
1.4 QUALITY ASSURANCE
A. Due to the specialized nature of the specified work and products, all bidders shall be required to have a
minimum of five (5) years of operating history. The equipment described herein shall be products of a
manufacturer regularly engaged in the fabrication of filtration and recirculating systems for at least
fifteen (15) years and shall be a professional engineering corporation.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
14
B. The owner requires that filters bear the National Sanitation Foundation (NSF) seal for Standard #50.
This NSF listing is required by the owner regardless of local health department regulations.
C. The specified filter system shall have had an NSF listing for at least three (3) years prior to the project
bid date.
D. As assurance that each item of apparatus is properly sized to perform in conjunction with each other,
the owner requires bidders to use the filter manufacturer as a single source of supply for the items of
equipment as listed and described herewith.
E. The "EQUIPMENT SUPPLIER" shall be:
NEPTUNE-BENSON, INC.
COVENTRY, RHODE ISLAND
1-800-832-8002
1.5 GUARANTEE
A. The “EQUIPMENT SUPPLIER” shall guarantee that the equipment to be furnished is of the
correct capacity, that the various parts are designed to operate correctly and in conjunction with each
other, that if the installation is made in accordance with the project drawings and operated in accordance
with the suppliers instructions, the system will perform the prescribed functions correctly, the water
entering the pool will be clear, bright, free from suspended matter visible to the unaided eye, and will be
sanitary to the satisfaction of all authorities having jurisdiction.
1.6 SUBMITTALS
A. Provide detailed shop drawings of the items of equipment being provided, indicating the dimensions,
material of the filter tanks, valves, actuators, RMF system controller & accessory components.
B. Provide a complete set of operating instructions, embracing the operational functions and recurring
maintenance processes involved in connection with the complete filtration system.
INSTALLATION AND REMOVAL
1. INSTALLATION
Contractor will install equipment and provide training on equipment for staff. Equipment must be
installed with existing piping and connection. If additonal work is required, this must be specified in the
bid documents.
1.2 REMOVAL
Current filtration system must be removed and disposed of as part of the contract. Contractor will be
reponsible for responsible disposal of equipment. Any need of dumpsters will need to be obtained by the
contractor, current trash receptacles at the facility will not be utilized for the purpose of removal or
disposal of any materials pertaining to this project.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
15
FILTER SYSTEM
2.1 FILTER SYSTEM
A. The filter system under this section shall be a Defender Model.
B. It is the intent of these specifications to describe a filter system complete with all accessory items
supplied and warranted by one manufacturer.
C. The primary components of the system consist of the main filter tank, flex tube filter elements, element
assembly, bump mechanism, vacuum transfer system, sight glass, pressure gauge panel, inspection
(viewing) window, valves, pressure transducers & RMF system controller.
D. All components and related subassemblies shall be factory assembled and tested prior to shipment.
2.2 FILTER SYSTEM CAPACITY
A. The Pool filter system shall have a capacity of filtering _100,000_gallons in ___4__ hours at a rate of
__750_____ gallons per minute. The spa filter shall have a capacity of filtering 2,000 gallons in 2 hours
at a rate of 350 gallons per minute.
B. The system shall consist of ___2______ filter tank(s), one for a 100,000 gallon pool and one
for a 2,000 gallon whirlpool.
C. The filter area shall be provided as specified and as listed in NSF-Standard 50 to provide the specific
filter rate. No modification, manipulation or interpretation of these values shall be permitted.
D. Filter system shall be designed to maximize sq. ft. of filter area while minimizing operating weight.
Systems that operate in excess of 11 lbs. per sq. ft. of filter area shall not be considered.
2.3 FILTER TANKS
A. The filter tank shall be suitable for 50 psi working pressure and hydrostatically tested to 75 psi.
Tank shell shall be not less than ¼” thick. Bottom dished head shall be not less than ¼” thick. Top
flat head shall be not less than 1 1/4” thick. All material shall be Type A-36 carbon steel.
NOTE: Tanks constructed of alternate materials shall not be considered.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
16
B. All welding shall be performed by qualified operators. Joints shall be butt or fillet welded inside
and out by manual or automatic process. Welded joints shall have complete penetration and fusion
with little or no reduction of the thickness of the base metal. Welds shall be free of coarse ripples,
grooves, overlaps, abrupt ridges or valleys. All welded surfaces shall be chipped and brushed clean,
when necessary, leaving no slag or splatter.
C. Tank legs shall be constructed of 6” x 2 ½” channel legs ¼” thick. 24”, 27” and 33" filters shall
have (3) legs. 41”, 49” and 55” filters shall have (4) legs. The material shall be Type A-36 carbon
steel. Bearing plates shall be 10” x 5” x 1/4” type 304L stainless steel. Each bearing plate shall have
(2) 5/8" drilled holes to secure to the floor with the ½" x 4 ½" stainless steel concrete anchors
provided. The legs shall be designed with bolted connections to minimize overall tank height for
shipping and access into the mechanical room. OPTIONAL – REDUCED HEIGHT DEFENDER
– WELDED LEGS – 12” OAH REDUCTION.
D. The tank head shall be bolted to the shell with 7/8” diameter T304 stainless steel threaded rods and
nuts, 9” on center around the tank perimeter.
E. Tank shall be equipped with a UL listed grounding lug.
F. Tank shall incorporate connections for “filter influent, " effluent, " drain; 1-1/2" vacuum transfer
piping, 6” viewing window, and lift shaft gland.
OPTIONAL – FILTERS SP-27 THROUGH SP-55: Tank shall include a 12” diameter access port
with cover and hardware to facilitate cleaning of tube elements and interior inspection of filter.
G. Tank shall include brackets for mounting of RMF System controller, gauge panel, filter / regulator,
vacuum transfer blower, and vacuum hose rack.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
17
H. Tank shall include a integrally mounted hydraulic lifting device (davit). The davit assembly shall be
designed to lift the filter head and include a pivot mechanism allowing the head to rotate 180°, for access
to the tube sheet.
NOTE: Systems requiring additional devices for filter head removal will not be considered.
2.4 FLEXSOL 3000 INTERIOR LINING
A. All interior surfaces shall be grit blasted to white metal condition with a 3-4 mil profile. Blasted surfaces
shall be cleaned of all dust or blast residue. Lining shall be applied as soon as is practical on the same day
blasting is done.
B. Flexsol 3000® shall be a urethane, 100% solid plural component lining. Hardness shall be 75 durometer
on the shore D scale. Break tensile strength shall be 4000 psi with elongation of less than 10%. Adhesion
shall be greater than 2500 psi.
C. Application of Flexsol 3000® lining shall be done by experienced applicators using a high pressure, high
temperature plural component system. All wetted surfaces including flange faces, manway rings and
manway covers shall be lined to 100 mils +/- 10 mils WFT.
D. Hardness shall be verified after curing to ASTM D 2240 standard.
E. Manufacturer shall submit for approval a sample piece of coated steel to determine flexibility, abrasion
tolerance and adhesion integrity.
F. Flexsol 3000® lining shall meet the NSF toxicity standard unconditionally and shall be approved for use
with the NSF approved filter.
G. Flexsol 3000® lined vessels shall carry a ten (10) year limited non-prorated warranty.
H. The filter manufacturer shall bear the responsibility for suitability of lining and shall be the sole source for
the specified warranty.
2.5 EXTERIOR COATINGS
A. All exterior surfaces shall be grit blasted to white metal condition with a 2-3 mil profile. Blasted
surfaces shall be cleaned of all dust or blast residue and primed as soon as is practical on the same day
blasting is done.
B. When priming has dried the coating process will begin. If prime has sat for over twenty-four hours, a
refresher coat will be applied.
C. Two coats of high solids enamel shall be applied for a total developed film thickness of 5-8 mils.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
18
D. Manufacturer is to supply min.16 oz of high solids enamel touch-up paint.
2.6 INTERNAL COMPONENTS
A. The filter shall consist of flex tube elements, filter tube sheet, stainless steel lift shaft and internal flow
diversion assembly.
B. The filter elements shall be flexible tubes that provide the support structure for the media. The outer
wall of each element shall be fabricated of multi-filament high strength polyester braid. Each element
shall have an internal T304 (optional T316) stainless steel spring, which acts a support structure for the
braided filament.
C. The filter element tube sheet shall be fabricated of T304 (optional T316) stainless steel and provide
both support for the top of the element assembly as well as water tight seal to prevent media from
escaping the filter tank.
D. The lift shaft shall be fabricated from T304 (optional T316) stainless steel and provide the internal
connection between the filter element tube sheet and the external bump mechanism.
E. The filter influent connection shall be fitted with a T304 (optional T316) stainless steel flow diversion
assembly to eliminate disturbance to the filter elements during operation.
F. All stainless steel wetted fasteners shall be Type 304. (optional T316)
NOTE: Systems utilizing rigid elements with replaceable filter septum shall not be considered.
2.7 BUMP MECHANISM
The bump mechanism shall include a pneumatically operated tire mounted externally on the filter
tank head. The tire is alternately pressurized then depressurized causing the connected filter element
assembly to move in a downward then upward fashion. This movement shall provide the means of
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
19
dislodging the media and accumulated solids, which then recoat the filter element.
NOTE: Systems that do not incorporate a pneumatic bump mechanism shall not be considered.
2.8 VACUUM TRANSFER SYSTEM
A. The vacuum transfer system shall be provided to allow the recharging of media into the filter for either
bag or bulk media.
B. The vacuum shall include a 5 peak HP 115V single phase motor 60 Hz, cULus listed.
C. Vacuum shall be supplied with mating electrical connections pre-wired into RMF System controller for
field final connection in a pre-assembled junction box.
D. Provide three (3) 1-1/2” SCH 80 PVC ball valves: for the vacuum drain line, the blower inlet and the
vacuum hose.
E. The Manufacturer shall provide all necessary pipe, fittings and hardware for field plumbing of the
vacuum transfer system.
F. Provide 1-1/2” vacuum hose with required fittings.
NOTE: Systems requiring external precoat mixing tanks, slurry feed, or other wet media transfer
devices shall not be considered.
2.9 RMF SYSTEM CONTROLLER
A. The automatic controller shall provide total control of the system's filtration and regeneration cycles, and
provide all necessary equipment interlocks and timing mechanisms to execute the filter program.
B. The controller shall contain at least two microprocessors that will monitor all functions of the system.
C. The controller shall contain also control the operation of the following functions:
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
20
Standard Features
1. Bump cycle / manual or automatic; with or without security interlock for data logging
2. Precoating of the filter elements
3. Stopping and starting of the main recirculation pump
4. Opening and closing of pneumatically operated valving
5. Vacuum transfer system
6. Heater cool down delay
7. Auxiliary contacts to interlock UV lamps, chemical control, or other equipment
8. 7 inch Hi-Res LCD Screen with Tactile Feedback Membrane
9. Last Bump™ and Bump-n-Go™ Features
10. Remote Operation via browser or phone
11. Off Site Real-Time Status
12. Email on change of condition
13. Data logging of process
14. Differential Pressure Monitoring and Bump Control
15. Automatic maintenance reminders
16. Exporting of process data logs to .csv Excel™ files
17. Modbus Communications for PLC connectivity
D. The controller panel shall display the following functions:
1. Filter status
2. Precoat status
3. Last Bump
4. Recirculating pump status
5. Vacuum transfer pump status
6. System power
7. Low Pressure Alarm
8. Recirculating Pump Off Alarm
9. Pressure Differential
10. Flow Rate (when interlocked with VFD)
11. Step by step animated graphics
E. The controller enclosure shall be NEMA 4x/IP66 approved system.
F. The RMF controller will provide signal power to the main recirculating pump motor starter. The unit is
required to be a variable frequency drive (VFD) and is to be installed with control wiring by the
electrical contractor.
G. The RMF shall be 120V/230V, 1 phase, 20 amp rated and shall be UL labeled.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
21
H. NOTE: Systems without programmable, automatic bump/regeneration/filter modes shall not be
considered.
I. Options
1. Automated Main Drain and Purge Line Control Package
2. 24/7/365 Data Monitoring and Activity Package
3. Automated EZ Strainer Control for UV Systems.
2.10 VFD
A. A Variable Frequency Drive (VFD) shall be provided with each Defender (one per filter pump) for
control of the filter pump motor.
B. The Variable Frequency Drives (VFDs) shall be solid state, with a Pulse Width Modulated (PWM)
output. The VFD package as specified herein shall be enclosed in a NEMA 12 enclosure, completely
assembled, programmed and tested by the manufacturer. The VFD shall convert incoming fixed
frequency three-phase AC power into a variable frequency and voltage for controlling the speed of three-
phase AC induction motors. The VFD shall be a six-pulse input design. The VFD shall be of a PWM
output design utilizing current IGBT inverter technology and voltage vector control of the output PWM
waveform and shall output a waveform that closely approximates a sine wave.
C. Option for Single Phase input: The VFD shall convert incoming fixed frequency single-phase AC power
into a variable frequency and voltage for controlling the speed of three-phase AC induction motors. The
VFD shall be UL-listed for Single Phase operation. De-rating the VFD for operation on other than UL-
labeled voltages shall not be acceptable. The VFD shall be a six-pulse input design. The VFD shall be
of a PWM output design utilizing current IGBT inverter technology and voltage vector control of the
output PWM waveform and shall output a waveform that closely approximates a sine wave.
D. The VFD shall utilize VVCPLUS, an output voltage-vector switching algorithm, or equivalent, in both
variable and constant torque modes. VVCPLUS provides rated RMS fundamental voltage from the VFD.
This allows the motor to operate at a lower temperature rise, extending its thermal life. VFD’s that
cannot produce rated RMS fundamental output voltage or require the input voltage to be increased above
motor nameplate value to achieve rated RMS fundamental output voltage are not acceptable. VFD’s that
utilize Sine-Coded PWM or Look-up tables shall not be acceptable.
E. An Automatic Energy Optimization (AEO) selection feature shall be provided in the VFD to minimize
energy consumption in variable torque applications. This feature shall optimize motor magnetization
voltage and shall dynamically adjust output voltage in response to load, independent of speed. Output
voltage adjustment based on frequency alone is not acceptable for single motor VT configurations.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
22
F. An Automatic Motor Adaptation (AMA) function shall measure motor stator resistance and reactance
to optimize performance and efficiency. It shall not be necessary to spin the motor shaft or de-couple the
motor from the load to accomplish this optimization. Additionally, the parameters for motor resistance
and motor reactance shall be user-programmable.
G. Run permissive circuit shall be provided to accept a “system ready” signal to ensure that the VFD does
not start until isolation valves, seal water pumps or other types of auxiliary equipment are in the proper
state for VFD operation. The run permissive circuit shall also be capable of sending an output signal as a
start command to actuate external equipment before allowing the VFD to start.
H. All Green Drive VFDs shall be factory programmed per the unique requirements of each job per Neptune
Benson specifications. Programming shall include but shall not be limited to filter pump, remote
start/stop requirements, run confirm requirements and PID loop requirements.
I. VFDs and options shall be UL, CUL, and CE labeled as a component.
J. Harmonic Distortion Control:
a. The VFD shall provide internal DC link reactors to minimize power line harmonics and to
provide near unity power factor. DC Link reactor shall be installed so that power fluctuations
to the DC Capacitors shall be reduced to increase Capacitor life. VFDs without a DC link
reactor shall provide a 5% impedance line side reactor and provide spare capacitors.
K. Specifications:
a. Input voltage 200-240, 380-480, 575-600 VAC +/- 10%, 3 phase, 48-63 Hz.
b. Voltage tolerance + 10% or – 15% of specified line voltage.
c. Output Frequency 0 to 300 Hz. Operation above 60 Hz shall require
programming changes to prevent inadvertent high-speed operation.
d. Environmental operating conditions: -10 to 50 °C, 0 to 1000 meters above sea level, less than
90% humidity, non-condensing.
e. Enclosure shall be rated NEMA 12 or as specifically mentioned elsewhere.
L. The VFD shall be wired into the RMF system controller to provide remote for on/off and run confirm
functions. Wiring shall be by electrical contractor.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
23
M. The VFD shall be a Green Drive series.
N. The VFD shall be equipped with a bypass. Bypass option shall send the motor to bypass mode based on
an easily accessible door-mounted selector or based on the drive’s programmable relay. A bypass pilot
light shall provide indication of the bypass mode. The bypass mode shall provide overload protection.
Contactors shall be electrically and mechanically interlocked. An essential services mode shall send the
motor to bypass regardless of the selected mode.
O. The bypass enclosure shall be equipped with a circuit breaker/disconnect switch.
2.11 FLOWMETER
A. A digital flowmeter shall be included with a 4-20mA 0-10 VDC analog output.
B. The flowmeter shall be wired into the VFD to provide automatic speed control of the filter pump
motor.
C. The VFD shall compensate for varying filter head losses by maintaining the specified flowrate with
the 4-20mA output signal of the flowmeter.
2.12 FILTER / REGULATOR
Each filter shall include a combination filter / regulator. The regulator shall be adjustable from 0 –
120 p.s.i. 1/2” F.P.T. connections shall be provided for field installation of air lines.
2.13 WATER SEPARATOR
One water separator with automatic drain shall be included for each air compressor supplied. 1/2”
F.P.T. connections shall be provided for field installation of air lines.
2.14 AIR COMPRESSOR
The system will require (1) air compressor per mechanical room. The following is the minimum
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
24
requirement:
20 gallon tank, 2 HP 115v, 1 phase, 15 amp, 5.2 CFM @ 90 psi, air pressure gauge, pressure relief
valve, belt guard, pressure switch, air filter, tank drain.
2.15 PNEUMATIC ACTUATORS
A. Each filter shall include pneumatic actuators for (1) effluent valve and (1) precoat valve.
B. The actuators shall be double acting with valve mounted drilling to ISO 5211.
C. The actuators shall include (2) 1/4" FPT ports for open / close connections. Flow control valves with
quick connect fittings shall be provided at each port to allow speed control adjustment for the open /
close function of the actuators.
D. Materials of Construction
1. Body: aluminum alloy, extruded acc. to ASTM 6063, anodized acc. to UNI 4522
2. Ends: Die-cast in aluminum alloy acc. To ASTM B179, epoxy-polyester coated
3. Pistons: Die-cast in aluminum alloy acc. To ASTM B179
4. Pinion: Nickel-plated steel
5. Slideways: Acetal resin (LAT LUB 731320T)
6. Fasteners: AISI 304 Stainless steel
7. Springs: Zinc phosphate coated steel, pre-compressed
8. Seals: NBR Nitrile rubber
9. Lubricant: MoS2
E. The actuators shall be factory lubricated to allow for 1,000,000 maneuvers.
F. The actuators shall have adjustable travel stops for both directions.
G. Working temperature limits: 4ºF to 186ºF. NOTE: Systems utilizing manually operated valves shall not
be considered.
H. A tool kit for adjustment of pneumatic actuators shall be provided by the filter manufacturer.
2.16 SOLENOID VALVES
A. Each filter shall include three (3) single solenoid, 4-way valves mounted on a multi-station manifold
for operation of the pneumatic actuators and bump mechanism.
B. The solenoids valves shall include lighted DIN connectors.
C. The solenoid valves shall be factory lubricated and shall not require any field lubrication.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
25
D. The solenoid valves with multi-station manifold shall be located on the bottom of the automatic
controller, factory wired and include quick connect fittings for attachment to the pneumatic actuators and
bump mechanism.
E. The solenoid valves shall be SMC Series SY 7000.
2.17 VALVES
A. All valves 3” – 12” shall be constructed with cast aluminum ASTM B179S12C housing and fully coated
with Rilsan on all interior and exterior surfaces. Internal components include EPDM resilient lining,
Rilsan coated ductile iron disc and T304 stainless steel shaft. Valves 14” and larger shall be constructed
with cast iron housing epoxy coated and with nylon coated ductile iron disc.
B. Valves shall be butterfly valves and shall be provided for the influent, effluent and precoat lines.
2.18 SYSTEM VALVES
A. Each defender filter shall include Five (5) system valves to facilitate system fill after media recharge,
precoat/regeneration, influent & effluent for filtering and media dump/drain valve.
B. The precoat/regeneration and effluent valves shall be butterfly type with pneumatic actuators per 2.15.
C. The system fill valve shall be butterfly type with lever operator and shall be the same size as the
precoat/regeneration valve.
D. The influent valve shall be a wafer type check valve, ductile iron body w/double disc, SS type 304.
E. The dump/rinse valve shall be butterfly type, lever operated with SS extension to facilitate operation.
2.18a MAIN DRAIN & TDS (optional)
Each defender shall include a pneumatically operated drain valve and precoat vent valve to assist with
removing debris from the tank bottom and to provide controlled water to waste for makeup & TDS control.
2.18b EZ STRAINER FOR UV (optional)
A wafer type EZ Strainer shall be provided with a pneumatically operated 180° actuator with solenoid
valve for UV for automatic cleaning of collected debris.
2.19 DRAIN REQUIREMENTS (BY OTHERS)
A. A sump pit or stand pipe is required for dumping spent media and rinsing tube elements.
B. To prevent overflow the sump or stand pipe drain piping should be sized for 300 gpm capacity.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
26
C. If drain piping cannot be sized for 300 gpm, or if the sewer is at an elevation higher than the filter tank
drain, use the following minimum sump sizes:
Model SP-24 130 gals
Model SP-27 160 gals
Model SP-33 250 gals
Model SP-41 450 gals
Model SP-49 620 gals
Model SP-55 850 gals
Use a sump pump to transfer waste to sewer.
NOTE: Systems that can not dump spent media by gravity drain only shall not be considered.
2.20 PACKAGING
A. For loading and unloading, filter tank diameters 24” – 41” shall be bolted to individual wooden pallets.
Filter tank diameters 49” and 55” shall be equipped with temporary lifting legs. All tanks shall be
shrink wrapped to prevent damage during transport.
B. The components shall be carefully packaged in a totally enclosed wooden crate to prevent damage
during transport.
2.21 MEDIA
A. Media shall be expanded perlite with a median particle size of 37 microns. Percentage retained on a
+150 Tyler Mesh shall not be less than 8% or more than 25%. Darcy permeability shall be between 1.2-
1.85.
B. The media shall contain no more than 1 tenth of one percent (.001) of crystalline silicate.
C. The media shall be certified by the Manufacturer for use in the Defender Filter. The media shall be
NSF Std. 50 listed.
D. The media shall be Aquaperl/Harborlite.
F. Each Defender filter shall be furnished with six (6) charges of perlite media.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
27
2.22 FILTER CLEANER
A. Each Defender filter shall be furnished with one (1) charge of chemicals for cleaning and degreasing of
filter tube elements.
2.23 WARRANTIES
A. Defender filter tanks with Flexsol 3000 shall carry a 10 year limited fully rated warranty as regularly
offered by the tank manufacturer.
B. Internal components, including tube elements, shall carry a fully rated 10 year warranty.
C. Valve bodies shall carry a 5 year fully rated warranty.
D. Valve operators and system accessories including the RMF controller, quick exhaust valve, solenoid
valve and bump mechanisms shall carry one year warranty as provided by the product manufacturer.
E. Unless otherwise specified, workmanship is to be guaranteed first class and carry a one (1) year
warranty.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
28
BID FORM
(Name of firm or individual bidding)
REQUEST FOR BIDS
FOR
FURNISHING, DELIVERY AND INSTALLATION
OF
POOL FILTRATION SYSTEM REPLACEMENT
FOR
THE CURATORS OF THE UNIVERSITY OF MISSOURI
FOR
THE UNIVERSITY OF MISSOURI – ST LOUIS, MO
RFB # 20 6006 JS S
CLOSING DATE: April 16, 2020
TIME: 3:00 PM, Central Time
The undersigned proposes to furnish the following items and/or services at the prices quoted and agree to
perform in accordance with all requirements and specifications contained within this Request for Bid issued by
the University of Missouri.
Please attach separate, detailed documents addressing qualifications, references, breakdown of price, warranty,
delivery and any other items requested previously in this bid.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
29
AUTHORIZED BIDDER REPRESENTATION
Number of calendar days delivery after receipt of
order
Payment Terms
Authorized Signature
Date
Printed Name
Title
Company Name
Mailing Address
City, State, Zip
Phone No. Federal Employer ID No.
Fax No.
E-Mail Address
Circle one: Individual Partnership Corporation
If a corporation, incorporated under the laws of the State of__________
Licensed to do business in the State of Missouri? ____yes _____no
This signature sheet must be returned with your bid.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
30
ATTACHMENT A
SUPPLIER DIVERSITY PARTICIPATION FORM
The University of Missouri System is committed to and supports supplier diversity because it is essential to the
University’s mission and core values. The University’s Supplier Diversity efforts reflect this mission.
Tier 2 Supplier Diversity Information - The University strongly encourages Supplier Diversity participation in all of its
contracts for goods and services. Tier 2 Spend is spend reported by primary suppliers of the University of Missouri who
subcontract work to, or make purchases from a diverse supplier. Depending upon the contract, primary suppliers will be
asked to submit Tier 2 information with Women and Diverse Owned companies. Suppliers have two options in reporting
Tier 2 dollars depending on the terms of the contract: Direct and Indirect. Awarded suppliers may be asked to utilize
CVM Solutions for reporting Tier 2 spend.
Direct dollars - those dollars directly spent with Women and Diverse Owned suppliers in the fulfillment of the
contract.
Indirect dollars - based on a percentage of revenue the University represents to the supplier. An example is as
follows:
o Supplier's Total Revenues: $10,000,000
o Revenues from University $: $ 4,000,000
o University % of Total Revenues: 40% (#2 divided by #1)
o Total MBE Dollars $: $ 150,000
o Total WBE Dollars $: $ 150,000
o Total University Attributable MBE $: $ 60,000 (#3 multiplied by #4)
o Total University Attributable WBE $: $ 60,000 (#3 multiplied by #5)
o Total University Attributable MWBE $: $ 120,000 (Sum of #6 and #7)
o University % Attributable Revenue: 3% (#8 divided by #2)
1. Does your company have a Supplier Diversity Program? If so, describe efforts your company has made to
increase business with Women and Diverse Owned businesses (i.e. does your company have a policy statement,
participate in outreach activities, promote diverse firm subcontracting, publicize contract opportunities, provide
certification assistance, etc.?) Please provide examples (use additional pages if needed): ____________________
_________________________________________________________________________________
_________________________________________________________________________________
2. What percentage of your company's total contracting and procurement spend for the prior year was with Women
and Diverse Owned businesses? Are you able to provide this information specific to University of Missouri
business? ________________________________________________________________________
________________________________________________________________________
3. Complete the following table indicating the percentage your company will subcontract with certified Women and
Diverse Owned businesses should your company be the successful bidder. Note: If your company does not plan to
use Women and Diverse Owned businesses to fulfill your contract obligations, please explain why not.
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
31
Supplier Name
% of Contract
Specify Direct or
Indirect
If there are questions regarding supplier diversity at the University, contact Teresa Vest,
---------------------------THIS FORM MUST BE SUBMITTED WITH THE RESPONSE-----------------------
--
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
32
ATTACHMENT B
SUPPLIER REGISTRATION INFORMATION
Completion of this section is strongly encouraged. Please review and check ALL applicable boxes.
SMALL BUSINESS CONCERN: _____Yes _____No
The term “small business concern” shall mean a business as defined pursuant to Section 3 of the Small Business Act and
relevant regulations issued pursuant thereto. Generally, this means a small business concern organized for profit, which is
independently owned and operated, is not dominant in the field of operations in which it is bidding. We would consider
any firm with 500 employees or less a “small business concern”.
WOMAN OWNED BUSINESS (WBE): ______Yes _____No
A woman owned business is defined as an organization that is 51% owned, controlled and/or managed, by a woman. The
determination of WBE status depends solely on ownership and operation and is not related to employment. The firm
should be certified by a recognized agency (e.g., state, local, federal, etc.). Please see Public Law 106-554 for more detail.
MINORITY BUSINESS ENTERPRISE (MBE): _____Yes _____No
A minority business is defined as an organization that is 51% owned, controlled and/or managed by minority group
members. The determination of minority status depends solely on ownership and operation and is not related to
employment. The firm should be certified by a recognized agency (e.g., state, local, federal, etc.). Please see Public Law
95-507 for more detail. Place an X by the appropriate space below.
1. Asian-Indian - A U.S. citizen whose origins are from India, Pakistan and Bangladesh _______ (A)
2. Asian-Pacific - A U.S. citizen whose origins are from Japan, China, Indonesia, Malaysia, Taiwan, Korea,
Vietnam, Laos, Cambodia, the Philippines, Thailand, Samoa, Guam, the U.S. Trust Territories of the Pacific or the
Northern Marianas. _______ (P)
3. Black - A U.S. citizen having origins in any of the Black racial groups of Africa. _______ (B)
4. Hispanic - A U.S. citizen of true-born Hispanic heritage, from any of the Spanish-speaking areas Mexico, Central
America, South America and the Caribbean Basin only. _______ (H)
5. Native American - A person who is an American Indian, Eskimo, Aleut or Native Hawaiian, and regarded as
such by the community of which the person claims to be a part. _______ (N)
A Veteran or Service Disabled Veteran business is defined as an organization that is 51% owned, controlled and/or
managed by Veterans. The firm should be certified by a recognized agency (e.g., state, local, federal, etc.). Please see
Public Law 109-461 for more detail.
VETERAN BUSINESS ENTERPRISE _____Yes ______No
SERVICE DISABLED VETERAN BUSINESS ENTERPRISE _____Yes _____No
THIS IS NOT AN ORDER BID NO: 20 6006 JS S
BID DATE: 03/06/2020
33
MISSOURI FIRM: _____Yes _____No
A Missouri Firm is defined as an organization which has and maintains within the State of Missouri a regular place of
business for the transaction of their business.
SUPPLIER’S CERTIFICATION:
The undersigned hereby certifies that the foregoing information is a true and correct statement of the facts and agrees to
abide by the laws of the State of Missouri and the rules and regulations of the University of Missouri System now in
effect including any subsequent revisions thereof. Supplier acknowledges that it is his/her responsibility to keep the
information current by notifying the University of Missouri of any changes.
Signature of Person Authorized to Sign this Supplier Registration Information Form
Title: ______________________________________ Date: __________________