bharti automation bhspli gurgaon, haryana-122050 · bharti automation pvt. ltd. (a testing...
TRANSCRIPT
BHARTI AUTOMATION PVT. LTD.(A Testing Division) Bhspli
arlificial intelligence
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comcl N-u 29299RJ 1997 Pr COL3827
lssued To: Sample Description Date of Receipt: 26!0712019Date of Reportin 9i2410812019Subham Solar Solutions Pvt.Ltd.
R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
sssPL075,sssPL150
TEST REPORT
PV Module Safety Qualifi cation Requiremen!91[q4qg!i!g
Report Reference lD No
Date of issue
Total number oI pages ....
Testing Laboratory
Address ...................
Bharti Automation Pvt, Ltd. (A Testing Division)
Ptot No- 354, Sector 7, IMT Manesar, Gurgaon ,Haryana-'122051
Subham Solar Solution Pvt. Ltd.
Office:83, Paul Building Complex, Bidhan Road, SiliguriFactory:
R.S Plot No.lGulmakhari, Pradhan Nagar,Dist: Darjeeling, West Bengal
Applicant's name
Address ................
Test specification:
Standard ..........................
Test procedure
Non-standard test method
tEC 61215:2005 /lS 14286:2010
N/A
N/A
Crystalline silicon terrestrial photovoltaic (PV) modules (lvlulti-crystalline)
Model/Type reference : SSSPL300
Ratings .............................................: For the electrical rating for all models seetable
Manufacturer declared that all the modules from 10W to 300W; they are using the same mbox. Junction box also will be complying as per the requirements.
Test item description
@
aterial, except the jun
Trade Mark
Product Electrical Rating
Asholi GisAnalyst
TRN No.
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.
2. Totalliability ofour Lab is limited to the invoiced amount.
3. Samples will be destroyed after 3 months from the date of testing un less otherwise specified.
4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permassion in writing.5. Report refer fo the sample submatted to us and not drawh by Bha rti Automation Pvt. Ltd unless menti6ned otherwise.
111033
TEST REPORT
190726009
24t08t2019
20
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u29299RJ1997PTCo13827
BHARTI AUTOMATION PVT. tTD.(A Testing Division)
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOTS,SSSPLl50
Samp le Description:
ID: 190726009 Page o
Copy of marking plate
@EJ-ra,tn n-a' p.ul 8lllldrng CsnPl'r' 1d Flor' $neud-7i'@1:'- w.a B.rl.l' lndl'
ar src {1ootivr/l'!2, aM a-S SPGGtth, call T..?!rcr.tr.e 25 D.E- tEatistaa.l,l vaiucs .re rrotrllnal uttleis
M.xi m.,rn Pouror (PrnPdesllned as te3ted.
3(,(, .OO rl/l,P37.51 r,t-q, a/rs-oo v
\/olt.tt .t Mat. FowarC.,racftl ,t Max. Poilrcr
(Wrrr p)(trop)
a-56 A15A1000 vDc24OO pacrass AcLAss I t
rr.azq.KE'It\f I l\l r-I/A
ISt
TRN No.
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.
1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is nei
2. Totalliability of our Lab is limited to the invoiced amount.
3. Samples will be d estroyed after 3months from the date of testing u nless otherwise specified.
4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law
any advertising media without our special permission in writing.
5. Report refer to the sample submitted to us and not drawh by Bha rti Automation Pvt. Ltd unless menti6ned
oDeri cii'c.tIt vott.Scsliort Clrcrrit Curr.m
(voc){ lsc}
rizcd Sigqt r103 E
@
\/4 -\ -.';\ /therlh€Jrtsrei@)i%d.
and should not be used in
otherwise.
! t' i.rt n it. t t atLl rltt. hdlrlc-
N/A-Possible test case verdicts: - test case does not apply tothe test object ......................,..:
Pass (P)
Fail (F){est object does not meet the requirement
Module type Crystalline Solar Photo VoltaicShort CircuilCurrentat STC, (Adc)
Rated MaximumPower
at STC,(Watts)
MaximumSeries Fuse,
(A)
RatedCurrent at
STC, (A DC)lvlodel
Open CircuitVoltage atSTC, (V
dc)
RatedVoltage at
STC, (V dc)
10.22 10600 0.552 0.6022.15 18.57SSSPLOl O
104.07 4.33 75.1222.21 18.42 1000SSSPLOT5150 158.20 8.7722.09 '!8.00 1000QSSPL150
/<300'1 000 7 .97 8.81SSSPL3OO'rrd/It'-. 44.36 37 .4
Bhspliartificial intelligence
TEST REPORT
lssued To:
Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Date of Receipt: 2610712019
Date of Reportin 9:2410812019
wanll GELECTNICAL,HAZTND
> tri .rl a!fi. .6t ry {n 4d, r .tlt*.! .rritl' '3El ''i td't-r> 6l' a!.ftn.d !r-n $ rd hiJl & itt!*6 fid. -d" wr 6 tt'r Bo'uti> a. ArrLE d rt-!t-! hlth OC tdr.r. *t- 6"!lG d
'6t*l.d rn De
> to rr nrdh r inill tdd.t fttl $t n {4.
- test object does meet the requirement...
MaximumSystem
Voltage,(Vdc)
bl,l{x,6-\ r
Asholi Giri
artificial intelligence
TEST REPORT
BHARTI AUTOMATION PVI. LTD.(A Testing Division)
lssued To Sam le Descri tion Date of Receipt: 2610712019
Date of Reportin 9:241 081 2019Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOT5,SSSPLl5O
ID: 190726009 Page 3 of20
Description of module construction:Sample Random sampling f.om production
Module
Froni Cover Glass-EVA-Cell-EVA
Rear Cover Tedler
Frame Extruded aluminum, anodized
Dimensions (lx w x h) [mm]1960x990x40
Module area [m2l 1 .9404 m'
Minimum distance between current- carrying partsand module edge Imml
35.00 mm
Cell
Cell (include type) MSPVLM2P5
Cells (l x w) [mm] 156 x 156
Cellthickness [!m] 214
Cell area [cm2] 243.36
Number of cells 72Components and other
Cells Der bvpass diode
TyDe of bvpass diode 15 SQ045 MtC
No. of bypass diodes 3
Cell- and strinq connectors. Solder plated copper ribbons
Junction box Type BKT-PV-J84, Manufactured by BKT, Rated '1500 V dc, certified byCENEC
Cable PVC-F, Manufactured by ERXL SOLAR DC CABLE,4.00 Sq. mm, Rated1100 v Sunlight resiatant, certified by TUV.
type Helios H4, Manufactured by BKT, Rated 1000 V dc, 35 Amax, with 12 AWG cable certified by TUV.
Connectors
Adhesives (frame) ., PV 804
N/A
$ttrersr\ ttit
TRN No.
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is n
2. Total liability ofour Lab is limited to the invoircd amount
3. Samples willbe destroyed after3months from the date oftesting unless otherwise specified.
either in
4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.
5. Report refer io the sample submitted to us and not drawh by B ha rtiAutomation Pvt. Ltd unless mentibned otherwise.
111C3
mplied
BhspiPlot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation,comct N-u29299 RJ 1997 PT COL3827
PV 804Adhesives Uunction box)
Potting material (.junction box) .........: -rii,rF;\The 1SOOV rating certificate from TUV tor iunction y'.o$libte ano . )connector are provided by the client. 'L/*^-._^...,-_^.t_
Asholi Giri
BHARTI AUTOMATION PVT. LTD.(A Testing Division)
artiticial intelligence
TEST REPORT
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comcf N-u29299 RJ 1997 Pr CAr3a27
issued To Sample Description:Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Ben gal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOT5,SSSPLl50
Page 4 oI20
Testing procedureNew module type
'1) Modification(if yes, please choose the applicable modiflcalion according to the Retesting Guideline)
2) Change in cell technology3) Modiflcation to encapsulation system
4) Modification to super strate5) lncrease in module size6) Modification to back sheeusubstrate7) Modification to frame and /or mounting structure8) Modification to junction bol:/ electrical termination9) Change in cell interconnect materials or technique10) Change in electrical circuit of an identical package11) Higher or lower power output (by 10%) in the identical package including size and using the identical
cell process12) Qualification of a frameless module after the design has received certification as a Aamed
module13) Change in bypass diode or number of diodes
Module group assignment:
Sample Sample Group lD Sample Si N
1 szE4190200217
2 B s2EA190200130
3 c1 s2EA190200131
4 c2 s2EA190200139
7 D,I 01112019200423
8 D2 01112019200422
trt 0't 112019200236
6 E2 01112019200479
uthorizcd SignaAlralyst
TRN No. t1103;NABL Accredited and ISO 9000:2015 certified Testing Laboratory.
Bhsgi
Date of Receipt: 2610712019Date of Reportin 9:24108120'19
ID: 190726009
1. The results listed refer only to tested samples and applicabie parameters. Endorsement of product is neither inferred nor implied.2. Totalliability of our Lab is limited to the invoiced amount.
3. 5a m ples will be destroyed after 3 mo nths from the date of testing u nless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any adve rtising med ia without our specia I pe rm issio n in writing.
5. Report refer t6 the sample submitted to us and not drawriby B ha rtiAutom ation Pvt. Ltd unless mentiohed otherwise.
BHARTI AUTOMATION PVT. LTD.(A Testing Division) Bh6gi
arlaf icial ;ntelligence
TEST REPORT
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u 29299 RJ 1997 P'r COL3827
Issued To: Sample Description: Date of Receipt: 2610712019Date of Reportin 9:241Q812019Subham Solar Solutions Pvt.Ltd.
R.S Plot No.1,G ulmakhari,PradhanNagar. Dist-Darieeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL010,SSSPLOT5,SSSPLl5O
ID: 190726009 Page 5 of 20
Clause Requirement * Test Verdict
MARKING P
Name, monogram or symbol of manufacturer Subham Solar Solutions Pvt. Ltd
Type or model number SSSPL3OO
300 Wp - Maximum output power
P - PolycrystallineP
Serial number szEA190200217 P
Polarity of terminals or leads Positive and Negative P
Maximum syslem voltage 1000
The date and place of manufacture 02t2019
uthorizcrlAsholr Giri
.\nah st
TRN No,
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability ofour Lab is limited to the invoiced amount.
3. Sa mp les will be destroyed after 3months from the date of testing un less otherwise specified-4. This report js not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report refer t6 the sample submitted to us and not drawri by Bha rti Automatio n Pvt. Ltd unless menlioned otherwise.
Result - Remark
4
P
P
t1103:
BHARTI AUTOMATION PVT. LTD.(A Testing Division)
artificial intelliqence
TEST REPORT
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comcl N-u29299RJ 1997 PT COL3a27
Samp le Description: Date of Receipti 2610712019Date of Reportin 9:2410812019Solar PV Module 300W
Model No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOTS,SSSPLl5O
lD:190726009 Page 6 of20
Requirement + Test Result - Remark Verdict
lnitial examination
10 Preconditioning P
10.1 Visual inspection See table 10.1 lnitial P
10.2 Maximum power determination P
1 0.3 P
10.15 See table 10.15lnitial P
Group A Control l\ilodule Sample Group A
Group B
10.4 Measurement of temperature coefficients See table 10.4 B P
10.5 Measurement of Nominal Operating Cell TemperaturelNocT.'c1 ..................................... :
See table 10.5 B P
10.6 See table 10.6 B P
'10.18 Bypass diode thermal test See table 10.18 B P
Maximum allowed junc{ion temperature P
P
uthorized Signnalyst
NABL Accredited and ISO 9000:2015 certified Testing Laboratory ng
1. The results listed refer only 10 tested samples and applicable parameters, Endorsement of product is neither inferred nor implied.2. Totalliability ofour Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified.4 This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report referto the sample submitted to us and not drawn by Bha rtiAutomation Pvt. Ltd unless mentioned otherwise.
Bh36i
lssued To:
Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulrnakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Clause
All modules
See table 10.2 lnitial
lnsulation test See table '10.3 lnitial
Wet leakage current test
'1 Module Sample Group B
Performance at STC and NOCT
Measured junction temperature
rRN No. 1 : I t'
BHARTI AUTOMATION PVT. TTD.(A Testing Division)
artificial intelligence
TEST REPORT
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:9L-124-4O4OBLS
e-mail :[email protected] :www.bhartiautomation.comct N-u29299RJ 19 97 PT COL3827
issueci To: Sam le Descri tion:Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Ben gal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOT5,SSSPLl50
ID: 190726009
Clause Requirement + Test Result - Remark Verdict
2 Modules Sample Group C P
10.1',| Thermal cycling test (50 cycles) P
Final measurements See appended table 10.'11 C P
10.12 Humidity freeze (10 cycles) P
See table 10.12 C P
Group Cl 1 Module Sample Group C'l P
10.14 Robustness of terminations test P
Final measurements See table 10.14 C1 P
Group E 2 Modules Sample Group E P
10.1 3 Damp heat test P
Final measurements See table 10.'13 E P
Group E1 1 Module Sample Group E1 P
10.16 Mechanical load test 2400Pa P
'10.16.4 -No open-circuits or ground faults detected No open circuit P
Final measurements See table 10.16 E1 P
l lvlodule Sample Group E2 P
10.17 P
11 P
Final measurements See table 10.17 E2 P
Final measurement K\f)Wet leakage current test /<,/tq/See table 10.15 F P \
nalyst
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters, Endorsement of product is neither infer re nor implied.2. Total liability ofour Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertjsjng media without our special permission in writing.
5. Report refer tb the sample submitted to us and not drawn by Bha rtiAutom ation Pvt. Ltd unless menticjned otherwise.
Bhspli
Date of Receipt: 2610712019Date of Reportin 9:2410812019
Page 7 of 20
Group C
Final measurements
I
Hail test
Number of points impacted.
I
lvnr-bAII modules
10.15
rRN No. 1j 1 C I i,
BHARTI AUTOMATION PVT. tTD.(A Testing Division)
artificial intelligence
TEST REPORT
Plot No.354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :info@bhartiautomation,€omwebsite :www.bhartiautomation.comcl N-u29299 RJ 1997 PT COL3A27
lssued To Sample Description: Date of Receipt: 2610712019
Date of Reportin 9:2410812019subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,Pradhan\agar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL010,SSSPLOT5,SSSPLl5O
Requirement * Test Result - Remark Verdict
10.'l lnitial TABLE: Visual inspection (lnitial) P
Test Date 27t07t2019
Sample Nature and position of initial findings - comments or attach photos
I No Visible Defect Pass P
2 No Visible Defect Pass P
3 No Visible Defect Pass P
4 No Visible Defect Pass P
5 No Visible Defect Pass6 No Visible Defect Pass P
7 No Visible Defect Pass P
8 No Visible Defect Pass P
Supplementary information: -
10.2 lnitial TABLE: Maximum power determination (initial) P
Test Date 29t07t2019
Module temperature
lnadiance [Wm2)'1000
Sample Voc [V] Vmp [V] lsc [Al lmp [A] Pmp [W] FF t%l1 45.9 38.8 L79 8.24 319.5 79.2
79.22 38.3 8.75 8.25 315.63 8.67 314.64 45.6 38.6 8.69 8.22 317 .0 80.05 45.8 38.0 8.25 78.46 45.9 38.0 8.75 314.6 78.47 8.78 8.30 78.78 38.3 8.76 8.28 3't7.4
Su lementa information: -
nltst
TRN No.
NABL Accredited and ISO 9000:2015 certified Testing Laboratory
::i
Bhsrti
lD:190726009 Page 8 of20
Clause
P
45.645.6
8.71 313.2
45.8 38.1 316.246.1
'/' \
1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor impl;ed.2. Totalliability of our Lab is limited to the invoiced amount.
3. Sa m ples will be destroyed after 3months from the date of testing u nless otherwise specified_
4 This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writjng.
5. Report refer tb the sample submitted to us and not drawriby Bha rtiAuto matio n Pvt. Ltd unless mentioned otherwise.
BHARTI AUTOMATION PVT. LTD.(A Testing Division) Bh6gi
artilicial intelligence
Plot No.354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation.comclN-u29299RJ 1997PTCo13827
lssued To Date of Receipt-. 2610712019Date of Reportin 9:2410812019Subham Solar Solutions Pvt.Ltd.
R.S Plot No.l,Gulmakhari,Pradhaniiagar, Dist-Darjeeling,West Bengal
ID: 190726009 Page 9 of20
Requirement * Test Result - Remark Verdict
10.3 lnitial Table: lnsulation test (initial) P
Test Date 30t07 t2019
Test Voltaqe applied [Vj 3000 for 1 min. / '1000V for 2 min
Sample Measured Required Dielectric breakdown Result
MO MO1 >20.62 NO PASS
>20.62 20.62 NO PASS3 >20.62 20.62 NO PASS4 >20.62 20.62 NO PASS5 >20.62 20.62 NO PASS6 >20.62 20.62 NO PASS7 >20.62 20.62 NO PASSI >20.62 20.62 NO
Supplementary information: Size of module [m1: 1.94
10.15lnitial TABLE: Wet leakage current test (lnitial) P
30t07 t2019
Test Voltaqe applied [V] 1000
Required Measured
3280
Solution resistivity [0 cm]
< 3,500 O cm at 22 !3'C0.027 PSurface tension [Nm-2] <003Nm2at22+3"C
Solution temperature ["Cl 24.5
Sample Measured [MQI Limit [MO] Result1 50.56 20.62 PASS2 45.65 20.62 PASS3 48.62 20.62 ,,< PASS4 65.89 20.62 PASS
20.62 q PASS6 40.25 20.62 . PA$S
55.45 20.62 "treB$'"'20.62 PASS50.33I IETRN No.
cc re e an ce te est tng oratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability of our Lab is limited to the invoiced amount.
3. Sa m ples will be destroyed after 3 months from the date of testing u nless otherwise s pecified.
4. This report is not to be reproduced.wholly or ln part and cannot be used as a n evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report refer tb the sample submitted to us and not drawn by Bharti Auto matio n Pvt. Ltd unless menticjned otherwise.
TEST REPORT
Sample Description:Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPLci 0,
SSSPLOT5,SSSPLl5O
Clause
20.62
PASS
Test Date.
P
5 45.61
7
BHARTI AUTOMATION PVT. tTD.(A Testing Division) Bhsli
artificial intelligence
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u 29299RJ 1997 PT COL3827
issued To Samp le Description Date of Receipt: 2610712019Date of Reportin 9:2410812019Subham Solar Solutions Pvt. Ltd.
R.S Plot No.1,G ulmakhari,PradhanNagar, Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL010,SSSPLOT5,SSSPLl5O
ID: 190726009 Page 10 of 20
Clause Requirement + Test Result - Remark Verdict
10.48 TABLE: Measurement of temperature coefficients P
Test Date
Ambient air temperature ["C] 25.5
lrradiance Wm2l '1000
Module temperature ["C] 68.3
Sample Parameter Calculated Value
2 q lo/ol"C\ . 0.0550
2 ts t%fc) -0.3936
2 6l%fc) -0.5505
Supplementary information
10.58 TABLE: Measurement of Nominal Operating Cell Temperature INOCT, 'C) P
0310812019 05t08t2019
Wind velocity [m/s] high/ low 1.74tO.27 1 .7 4t0.28 1.7410.28
Ambient temperature ["Cl high/ low 24.8t19.6 25.8t17.9 25.1t16.5
lrradiance Wm2] high/ low 954.791582.32 991.821518.67
Module temperature ['Cl high/low 55.9/36.05 57.1t38 56 65t33
Wind velocity Im/sl(averaqe) 0.903 0.822 0.945
Ambient temperature ['C] (average) 22.77
NOCT correction factor ['C] Nit Nit
Calculated NOCT fCI 47 .04 47.74 P
Sample Average NOCT ['Cl46.67 P
Supplementary information: Aftach correction procedure and origin of module l-V correction parameters
uthorizcd Sign:rt
TRN No.
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.
TEST REPORT
01t0812019
Test Date. 07t08t2019
941 .46t522.79
22.809 21.4
Nit
45.94
1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability of our Lab is limited to the invoiced amount.
3. Sa m ples will be destroyed after 3 months from the date of testing u n less otherwise specified.4 This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report referto the sample submitted to us and not drawn by B ha rtiAutomation Pvt. Ltd unless mentiohed otherwise.
BHARTI AUTOMATION PVT. TTD.(A Testing Division) Bhs6i
artiflcial intelligence
TEST REPORT
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation.comcl N-u 29299 RJ 1997 Pr COL3A27
Sample Description D.ile of Receipt: 2d4712019Daie of Reportin 9:2410812019Solar PV Module 300W
Model No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOT5,SSSPLl50
ID: 190726009Clause Requirement + Test Result - Remark Verdict
tl of20
't0.6 B TABLE: Performance at STC and NOCT P
07t08t2019
Wind velocity [m/s]Test method indoor
Ambient air temperature ['C] 25.5
lrradiance M/m'?l high/low 1000/800
Module temperature ['C] high/low
Condition Voc fvl Vmp [V] ,sc [A] lmp [A] Pmp [W] FF [o/ol
45.6 7 .25 315.6
NOCT 35.3 8.21 7.01 302 65Supplementary information
Ashol< Girithorized Sign.\llalJ"st
TRN No.
. NABL Accredited and lS0 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability ofour Lab is limited to the invoiced amount.
3. Sa m ples will be destroyed after 3months from the date of testing u n less otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without ourspecial permission in writing.5. Report refertd the sample submitted to us and not drawn by B ha rti Automation Pvt. Ltd unless mentioned otherwise.
Issued To:
Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,PradhanNagar, Dist-Darjeeling,West Bengal
Test Date.
46.9t25.1
STC 79.2
BHARTI AUTOMATION PVT. tTD.(A Testing Division) Bhspli
artificial intelligence
TEST REPORT
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N -u29299 RJ 1997 PT C0 L3827
issued To: Sample Description: Date of Receipt: 2610712019Date of Reportin g:?41A812019Subham Solar Solutions Pvt.Ltd.
R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOT5,SSSPLl5O
ID: 190726009CIause Requirement * Test Result - Remark Verdict
12 of20
10.1.t c TABLE; Thermal cycling 50 test P
Test Date O2l OBl20 1 9 lo 1 31 08120 1 ITotal cycles (50) 50
Sample Open circuits (yes/no)
3 P
4 No P
Supplementary information
(10.1 Visual inspection after thermal cycling 50 test) P
Test Date
Sample Nature and position of initial findings - comments or attach pholos
3 No Visual Defect Pass P4 No Visual Defect Pass P
Supplementary information
(10,2 Maximum power determination after thermal cycling 50 test) P
Test Date 10t19t2011
Module temperature ["C] 25
lrradiance w/m'z)Sample # Voc [V] Vmp [V] lsc lAl lmp [Al Pmp [W FF I%I
3 45.6 8.67 8.21 314.6 79.64 8.69 8.22 317.O 80.0
Pmp degradation after this testl%l<5ol.. 075 125
Supplementary information
({0.3 lnsulation test after thermal cycling 50 test)13lO8DO19
Test Voltage applied MRequired Dielectric breakdown
t\ro MO No\3 >20.62 20.62 qNO / pass \
>20.62 20.62 NO , "^-,.,P.aso'^-.-".
information: Size of module 1.94
TRN No.
No
13tO4t2019
1000
45.6 38.6
P
Test Date
3000 (for 1 min) 1000V for 2 min
lvleasuredSample #
4
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.l The results listed refer only to testird samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability ofour Lab is limited to the invoiced amount.3. 5a m ples will be destroyed after 3months fro m the date of testing un less otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
a ny advertising med ia without our s pecia I pe rm ission in writing.5. Report refer to the sample submitted to us and not drawri by BhartiAutomation Pvt. Ltd unless mentiohed otherwise.
BHARTI AUTOMATION PVT. LTD.(A Testing Division) Bhs6i
artilicial intelligence
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u 29299RJ 1997 PT COL3827
issued To Sample Description D.:te of Receipt: 2 A712019Date of Reportin 9:2410812019Subham Solar Solutions Pvt.Ltd.
R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL010,SSSPLOT5,SSSPLl sO
ID: 190726009C lause Requirement * Test Result - Remark Verdict
e 13 of 20
10.12 C TABLE: Humidity freeze 10 testTest Date [[r l,4/DD/yYfY] start/end I 4|OA2A 19 ro 24 I 08120 1 ITotal cycles (10) 10
Sample Open circuits (yeslno)
NO
4 NO
Supplementary information: --
{10,1 Visual inspection after humidity freeze l0 test} P
Test Date 24t08t2019
Sample Nature and position of initial findings - comments or attach photos
No Visual Defect Pass P
4 No Visual Defect Pass P
Supplementary information: -(10.2 Maximum power determination after humidity freeze {0 test} P
Test Date 24t08t2019
Module temperature I"Cl.lrradiance {Wm2) 1000
Sample Voc lVl Vmp [V] lsc [A] lmp IAI Pmp IWI FF I%I3 45.6 8.67 8.21 314.6 79.64 45.6 38.6 8.69 8.22 317.0
Pmp degradation after this test [%] <5% 1.21 1 .71 P
Supplementary information
(10.3 lnsulation test after humidity freeze 10 testl P
Test Date 24108t2019
Test Voltage applied M 3000 (for 1 min) '1000V for 2 min
Sample Measured
MO
MeasuredMO
IIA
3 102 20.82 NO PASS I
4 20 62 NO t},^.i',P"SS-S"""Jinformation: Size of module 1.54
alvst
TRN No.
NABL Accredited and ISO 9000:2015 certified Test;ng Laboratory.l The results listed refer only to tested samples and applica ble parameters, Endorsement of product is neither inferred nor implied.2. Total liability ofour Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report refer to the sample submitted to us and not drawn by B h a rti Automation Pvt. Ltd unless mentioiled otherwise.
TEST REPORT
P
3
3
80.0
ADielectric breakdown
No,E/
101
Bhs6i
TEST REPORT
Sample Description: Date of Receipt: 2610712019
Date of Reportirlg:241 0812019Solar PV Module 300W
Model No.SSSPL300Series Model No.SSSPLCi 0,
SSSPLOT5,SSSPLl5O
ID: 190726009 Page 14 of20
Requirement + Test Result - Remark Verdict
P10.14 C1 TABLE: Robustness of terminations tesl
Test DatePType C: connectorTypes of terminations
Applied force in all directions INI 0.5
PSample Open circuits (yes/no)
3
Supplementary informalion: -P(10,1 Visual inspection after robustness of terminations test)
24t08t2019Test Date
Sample Nature and position of initial findings - comments or attach photos
3 No Visible Defects Pass
Supplementary information
(10.2 Maximum power determination after robustness of terminations test)
Test Date 24/08t2019
Module temperature I"Cl1000lrradiance w/m2)
lsc [Al lmp [A] Pmp [W] FF lyolSample Voc [V] vmp [v]236.806 73.437.680 29.891 7.922
1.27Pmp degradation after this lestl%lss%
Supplementary information
(10.3 lnsulation test after robustness of terminations test)24t0812019Test Date3000 (for 1 min) 1000V for 2 minTest Voltage applied M
Dielectric breakdownMeasured Required Result
MO MO No
Sample
PASS20.62 NO3 2350
Supplementary information: Size of module (m'?): 1.94
nrl)st
TRN No. '
NABL Accredited and ISO 9000:2015 certified Testing Laboratory1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.
2. Totalliability of our Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified.
4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.
5. Report refer io the sample submitted to us and not drawh by tharti Automatio n Pvt. Ltd unless mentioned otherwise.
BHARTI AUTOMATION PVT. LTD.(A Testing Division)
artirlcial intelligence
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u 29299RJ 1997 PT C0L382t
lssued To:
Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,Pradhani!a ga r,Dist-Darjeelin g,West Bengal
Clause
24t0812019
No
P
8.5113
P
BHARTI AUTOMATION PVT. tTD.(A Testing Division) Bhspli
adificial intelligence
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u 29299RJ 1997 PT COt3827
Sample Description: Date of Receipt: 2610712019Date of Reportin 9:2410812o19Solar PV Module 300W
Model No.SSSPL300Series Model No.SSSPL0i 0,
SSSPLOT5,SSSPLl5O
lD:190726009CIause Requircment * Test Result - Remark Verdict
P 15 of20
10.16 E1 TABLE: Mechanical load test P
Sample 7
Test Date
l\rounlino method As per lnstallation ManualLoad applied to Front side Back sidel,rechanical load IPal 2400 2400First cycle time (starUend) 09:00AM/10:00AMlntermittent open-circuit (yes/no)
Second cycle time (slaruend) 12:00PlI/01:00PMIntermittent open-circuit (yes/no) NOThird cycle time (starvend) 1:30PM/2:00PIvllntermitient open-circuit (yes/no) No
Supplementary information: Such as Maximum bending at module center(10.1 Visual inspection after mechanical load test) P
06i082019
Sample Nature and position of initial findings5
Supplementary information
(10.2 Maximum power determination after mechanical load test) P
Test Date 06/08/2019
Module temperature I'Cllrradiance {W/m2) 1000
Sample Voc [Vl Vmp fvl lsc [Al lmp IAl Pmp lWl FF I%1
7 45.8 38.1 8.78 8.30 78.7
Pmpde gradation after this test[%]<s% 1.17
Supplementary information
(10.3 lnsulation test after mechanical load test) P
Test Date
Test Voltage applied IVIlMeasured Required Dielectric breakdown\Sample
MO MO No
7 102.3 20.62 NO
S ta information: Size of module 1.94
rnalyst
TRN No.
NABL Accredited and ISO 9000:20L5 certified Testing Laboratory.l The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor im plied.
2. Total liability ofour Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5 Report refer to the sa m p le sub mitted to us a nd not d rawn by Bha rti Autom ation Pvt. Ltd un less mentiohed otherwise.
TEST REPORT
lssued To:
Subham Solar Solutions Pvt.Ltd.R.S Piot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Ben gal
06/08/2019
NO
Test Date
No Visual Defect Pass P
o6toat2019
3000 (for 1 min) 1000V for 2 min Ithesurt
,11
BHARTI AUTOMATION PVT. tTD.(A Testing Division) Bh66i
artiticial intelligence
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u 29299RJ 1997 PT COL3827
lssued To: Sam le Descri tion DaLe of Receipt: 2610712019
Date of Reportin 9:2410812019Subham Solar Solutions Pvt.Ltd.R.S Plot No.1,G ulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL01C,SSSPLOT5,SSSPLl5O
ID: 190726009 Page 16 of20
Clause Requirement + Test Result - Remark Verdict
TABLE: Hail impact test P
Test Date 06lo8t2a19
lce ball size lmmj 24.9
lce ball weight [g] 7.5324 14lce ballvelo m/s
Number of impact locations 11
Sample Open circuits (yes/no)
B NO
Supplementary information: (impact location descriptions)
('10,1 Visual inspection after hail impact test)06/08/2019
Sample Nature and position of initial findings - comments or attach photos
I No Visible Defect Pass P
Supplementary information
(10.2 Maximum power delermination after hail impact test) P
Test Date 06/08/2019
Module temperature ['C] 24.2
lrradiance w/mz)Sample Voc lvl Vmp [V] Isc lAl lmp JAI Pmp [W] FF I%I
8 46.1 8.76 317.4 78.6'1.39Pmpde gradation after this test [%]ssolo
Supplementary information
P(10-3 lnsulation test after hail impacl test)Test Date 06/08/2019
Test Voltaqe applied M 3000 (for 1 min) 1000V for 2 min
Measured Required Dielectric breakdownSample #MO MO No /.\s 99.2 20.62 NO / P."t \
leme information: Size of module 1.94Salvstll
TRN No.
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Total liability ofour Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report refertb the sample submitted to us and not drawri by Bha rti Autom ation Pvt. Ltd unless menticjned otherwise.
TEST REPORT
10.17 E2
P
P
Test Date..
1000
BHARTI AUTOMATION PVT. LTD.(A Testing Division) Bhsrti
artilicial intelligence
TEST REPORT
Plot No.354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comct N-u29299RJ 1997 PT CO!1A27
lssued To: Sam le Descri tio n Daie of Receipt: 2610712019
fi=te oi Reportin g:2414U2019Subham Solar Solutions Pvt.Ltd.R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL0I 0,
SSSPLOT5,SSSPLl5O
ID: 190726009 Page 17 oI20
Clause Requirement + Test Result - Renrark Verdict
10.2 F TABLE: Maximum power determination (final) P
Test Date 24t08/2019
Module temperature ["C]
1000
Sample # Voc [V] Vmp [V] lsc [A] lmp [A] Pmp Wl Degradationl%1
Limit [%]
1 37 .465 8.463 7.936 237 .813 0 -8
2 37.39 29.3 8.46 7 .84 73 229.85 3.07 I3 37.611 29.822 8.523 7 .925 7 3.7 236.325 1.48 -8
4 8.530 7 .920 72.9 233.519 1 .92
5
6
7 72.5 230.643 4.41 -8
I 37 .209 29.036 8.532 7 .876 72.O 228.695 -8
Supplementary information
ualvst
33TRN No.
lrradiance [W/m2)...
FF lo/o1
29.966 75
37.575 29.485 -8
37.181 29.301 8.562 7 .8720.46
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliabilityof our Lab is limited to the invoiced amount.
3. Samples will be destroyed after 3months from the date of testing u nless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.5. Report refer tb the sample submitted to us and not drawn by Bharti Automatio n Pvt. Ltd unless mentic,ned otherwise.
BHARTI AUTOMATION PVT. LTD.(A Testing Division)
TEST REPORT
lssued To: Date of Receipt: 2610712019Date of Reportin 9i2410812019Subham Solar Solutions Pvt,Ltd.
R.S Plot No.l,Gulmakhari,Pradhani.:agar,Dist-Darjeeling,West Ben gal
ID: 190726009 Page 18 of 20
C lause Result - Remark Verdict
10.15 F TABLE: Wet leakage current test (final) P
Test Date 24/08t2019
Test Voltage applied [Vl 1000
Required
Solution resistivity [O cm) < 3,500 Q cm at 22 13"C 2450,',t730,3345,3200
P
Surface tension [Nm'2) < 0.03 Nm-z at 22 a3"C 0.03,0.029 P
Solution temperature ['C] 23.5, 22.2, 23.3, 23
Sample # Measured [MO] Limit [MO] Result
1 118 20.62 PASS
2 113 20.62 PASS
98 PASS
4 '100 PASS
5 109 20.62 PASS
6 129 PASS
7 '1 15 20.62 PASS
8 PASS
thorized Signa
AMo
o-{t
5q
* *
1. The results Iisted refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability of our Lab is limited to the invoiced amount.
3. Samples will be destroyed after3months from the date oftesting unless otherwise specified,
4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.
5.. Report refertb the sample submitted to us and not drawn by BhartiAutomation Pvt. Ltd unless mentidned otherwise.
Bh36iartificial intelligence
Plot No.354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :www.bhartiautomation.comc I N - U 29299 R J 1 9 97 PT C0 L3827
Sample Description:Solar PV Module 300WModel No.SSSPL300Series Model *o.555PLi:i 0,
SSS PLO75,SSSPLl 5O
Requiremenl + Test
[reasured
3 20.62
20.62
20.62
114 20.62
Supplementary information: Size of module [m']: '1.94
Analyst
rRNNo. I ; , I j.,NABL Accredited and ISO 9000:2015 certified Testing Laboratory.
BHARTI AUTOMATION PVT. tTD.(A Testing Division)
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.:91-124-4040815e-mail :[email protected] :wwubhartiautomation.€omct N-u 29299RJ 1997 Pf COL3A27TEST REPORT
!ssued To: Sample Description: Date of Receipt: 2610712019Date of Reportin gi24l08l2019Subham Solar Solutions Pvt.Ltd.
R.S Plot No.l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL010,SSSPLOT5,SSSPLl50
ID: 190726009 Page 19 of 20
Photographs
Sample Front Veiw sample Back Veiw
.,\nalyst
TRN No.
.\uthorized Signat0
NABL Accredited and ISO 9000:2015 certified Testing Laboratory. 'i:lgl/--'1. The results listed refer only to tested samples and applicable parameters. Endorsement of product is neither inferred nor implied.2. Totalliability ofour Lab is limited to the invoiced amount-
3. Samples will be destroyed after 3months from the date of testing u nless otherwise specified.4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing-5. Report referto the sample submitted to us and not drawn by B ha rtiAuto mation Pvt. Ltd unless mentiohed otherwise.
Bhzgiartiticial intell;gence
\
it
l'
Fr {$rFE
BHARTI AUTOMATION PW. tTD.(A Testing Division)
Plot No. 354, Sector-7, IMT ManesarGurgaon, Haryana-122050Ph.: 91-124-4040815e-mail :[email protected] :wwwbhartiautomation.comct N-u 29299 RJ 1997 PT COL3827TEST REPORT
issued To Samp le Description:Subham Solar Solutions Pvt.Ltd.R.S Plot No.'l,Gulmakhari,PradhanNagar,Dist-Darjeeling,West Bengal
Solar PV Module 300WModel No.SSSPL300Series Model No.SSSPL010,SSSPLOT5,SSSPLl5O
ID: 190726009 Prge 20 of 20
#
Terminal Box Connectors
isclaimer: The manufacturer declares that the lower rating modules are constructed using same materials,components and processes as the tested modules. Test results apply only to the sample(s) actually testedby Bharti Automation Pvt. Ltd. The applicant provided all ofthe test samples for testing by Bharti. Bharti didnol select the samples or determine whether the samples provided werc representative of other productsmanufaetured by appli6ant. Bharti has not established Follow-Up Service or other surveillance of theproduct. The applicant is solely responsible for continued compliance of products to all applicablestandards..
Test Report**'
A-uthorizcd Signa ol-\'
NABL Accredited and ISO 9000:2015 certified Testing Laboratory.1. The resu lts listed refer only to tested sa mples a nd applica b le pa ram eters. Endorsem ent of prod uct is ne ither inferred nor im plied.
2. Total liability ofour Lab is limited to the invoiced amount.
3. Sa m ples will be destroyed after 3 months fro m the date oftesting un less otherwise specified.
4. This report is not to be reproduced wholly or in part and cannot be used as an evidence in the court of Law and should not be used in
any advertising media without our special permission in writing.
5. Report refer io the sample submitted to us and not drawh by Bha rtiAutomation Pw. Ltd unless mentidned otherwise.
Bhspliartilicial intelligence
Date of Receipt: 2 A712019
Date of Reporiirtg:241 0Bl 2019
Asho!r GiriAnalyst
TRN No. . , l