berridge testing and certifications …€¦ · astm e-1680 - rate of air ... spanish tile roof...

8

Upload: duongnhi

Post on 18-Apr-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n
Page 2: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

For actual test results, technical questions, fastener types, fastener spacing or job-specific engineering, please contact the Berridge technical department at (800) 669-0009 or [email protected]. Updates and additional testing are added on a continual basis. Consult the Berridge technical department for the latest updates.

* 1" tall seam is UL-90 wind uplift approved for both steel and aluminum. 1 1/2" tall seam is UL-90 wind uplift approved for steel only ** Use continuous ribs for ASTM E-1646, ASTM E-1680, ASTM E-331, and ASTM E-283 compliance

*** See HR-16 Panel for test results on ASTM E-331 and ASTM E-283 with similar panel seams

UL 90 - Uplift test of roof systemUL 1897 - Uplift test of roof systemUL 790 - Fire test of roof systemUL 263 - Fire test of construction and materialsUL 2218 - Impact resistance of prepared roof covering materialsASTM E-1592 - Structural performance of sheet metal roof and siding systems by uniform static air pressure differenceASTM E-330 - Structural performance of exterior windows, doors, skylights and curtain walls by uniform static air pressure difference

ASTM E-2140 - Water penetration of metal roof panel systems by static water pressure headASTM E-1646 - Water penetration of exterior metal roof panel systems by uniform static air pressure differenceASTM E-1680 - Rate of air leakage through exterior metal roof panel systemsASTM E-331 - Water penetration of exterior windows, skylights, doors and curtain walls by uniform static air pressure differenceASTM E-283 - Rate of air leakage through exterior windows, curtain walls and doors under specified pressure differences across the specimen

FM 4471 - This standard states approval requirements for Class 1 panel roofs. A Class 1 panel roof meets the criteria of this standard for fire, wind, foot traffic and hail damage resistance Florida Product Approval - Standard of practice for product evaluations and consistency of enforcement for the state of FloridaMiami-Dade Approval - Established with its main goal to allow new and innovated ideas to be developed into useful, practical, lasting and safe products for use in high velocity hurricane zones

STANDING SEAM ROOF PANELSWind Fire Impact Wind Wind and Water Wind

UL 580 UL 90 UL 1897 UL 790 UL 263 UL 2218 ASTM E-1592

ASTM E-330

ASTM E-2140

ASTM E-1646

ASTM E-1680

ASTM E-331

ASTM E-283 FM 4471

FLPRODUCTAPPROVAL

MIAMIDADE

TDI LISTED

ICC-ES Report

CEGS 07416

Tee-Panel o o n o o o o o n

High Seam Tee-Panel* o o n o o o o o n

Tee-Lock Panel o o o o o n o o o o o o

Cee-Lock Panel** o o o o n o n n n n n o n o n

Zee-Lock Panel (Single Lock)** n n n n n n n n n n n n n n n

Double-Lock Zee-Lock Panel** o n o n n n n n n n n n n o n o n n

OTHER ROOF SYSTEMS UL 580 UL 90 UL 1897 UL 790 UL 263 UL 2218 ASTM E-1592

ASTM E-330

ASTM E-2140

ASTM E-1646

ASTM E-1680

ASTM E-331

ASTM E-283 FM 4471

FLPRODUCTAPPROVAL

MIAMIDADE

TDI LISTED

ICC-ES Report

CEGS 07416

Bermuda Roof Panel n n n n

Spanish Tile Roof System n n n n n n

S-Tile Roof Panel n n n n n n n n

Batten Seam Roof System n n n n n

Victorian & Classic Shingles n n n n n

Fish Scale

Curved Flat Seam Panel

"M" Panel n n n n

"R" Panel n n n n

Deep Deck Panel n n n o o o o o

S-Deck n n o o o

Double Rib Panel n n n n

FASCIA, WALL & SOFFIT PANELS UL 580 UL 90 UL 1897 UL 790 UL 263 UL 2218 ASTM E-1592

ASTM E-330

ASTM E-2140

ASTM E-1646

ASTM E-1680

ASTM E-331

ASTM E-283 FM 4471

FLPRODUCTAPPROVAL

MIAMIDADE

TDI LISTED

ICC-ES Report

CEGS 07416

HS-8 & HS-12 Wall Panels*** o o o o o

HR-16 Panel o o o o n n

Vee-Panel

FW-12 & FW-1025 Panels o o o o n o

L-Panel n n n

B-6 Panel n

Flush Seam n n n

Thin-Line n n

Fluted Fascia Panel n n

BERRIDGE TESTING AND CERTIFICATIONS SUMMARY CHARTn - Steel only o - Steel and Aluminum

Page 3: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

STANDING SEAM ROOF SYSTEMS

1”

12 ¾” Coverage 18 1/4” Coverage

16” Coverage

24 Gauge SteelLimited Availability: 22 Gauge Steel, 0.032 Aluminum

SpecificationsUses: Roof, Fascia*Coverage: 12 3/4” Finishes: SmoothFasteners: ConcealedApplications: Solid sheathingSeam: 1” snap-on with extruded vinyl weatherseal* Fascia can not be curved or tapered

24 and 22 Gauge Steel0.032 Aluminum

SpecificationsUses: Roof, Fascia*Coverage: 18 ¼” Finishes: Striated, optional smoothFasteners: ConcealedApplications: Solid sheathingSeam: 1” or 1 ½” snap-on with extruded vinyl weatherseal

* Fascia can not be curved or tapered

24 and 22 Gauge Steel0.032 and 0.040 Aluminum

SpecificationsUses: Roofing, Fascia*Coverage: 18” Finishes: Striated, optional smoothFasteners: ConcealedApplications: Open framing, solid sheathingSeam: 2 3/8” standing mechanically seamed sidelap Optional: Extruded vinyl weatherseal* Requires flashing break from roof to fascia

24 and 22 Gauge Steel0.032 Aluminum

SpecificationsUses: Roof, FasciaCoverage: 16 ½” or 11 ½”* Finishes: Smooth, optional striationsFasteners: ConcealedApplications: Solid sheathingSeam: 1 ½” snap-lock seamOptional: Extruded vinyl weatherseal* Contact BMC for material availability. Not available with striations.

24 and 22 Gauge Steel0.032 and 0.040 Aluminum**

SpecificationsUses: Roof, Fascia*Coverage: 16” Finishes: Smooth, optional striationsFasteners: ConcealedApplications: Open framing, solid sheathingSeam: 2” standing mechanically seamed sidelapOptional: Extruded vinyl weatherseal on continuous rib, snap-on batten cap* Fascia can not be curved or tapered ** Aluminum can not be curved or tapered

24 Gauge Steel 0.032 and 0.040 Aluminum

SpecificationsUses: Roof, Fascia*Coverage: 16” Finishes: Smooth, optional striationsFasteners: ConcealedApplications: Open framing, solid sheathingSeam: 2” standing mechanically seamed sidelapOptional: Snap-on batten cap, extruded vinyl weatherseal on continuous rib* Requires flashing break from roof to fascia

1” or1 1/2”

2”

16” Coverage

2”

TEE-PANELStraight, Curved and/or Tapered

HIGH SEAM TEE-PANELStraight, Curved and/or Tapered

TEE-LOCK PANELStraight

CEE-LOCK PANELStraight

ZEE-LOCK PANELStraight, Curved or Tapered

DOUBLE-LOCK ZEE-LOCK PANELStraight

18” Coverage

2 3/8”

16 1/2” or 11 1/2” Coverage

1 1/2”

COIL & FLAT SHEETSBerridge owns and operates its own continuous coil-coating paint line to provide fast, responsive service for coil and flat sheets. A wide array of long-life Kynar 500® /Hylar 5000® Berridge colors are available pre-slit for portable roll forming or in flat sheet form for custom trim and flashing fabrication. Branch locations have a large inventory of 24 gauge painted flat sheets in all our standard colors and slit coil in popular widths and colors for immediate pick up.

Berridge offers both factory-formed panels and a full-line of precision tolerance portable roll forming equipment to site-form standing seam roof panels. All Berridge portable roll formers are factory-set, dedicated profile machines that require no field adjustments. Site-formed panels require no end lap splices and are formed in continuous eave-to-ridge lengths. Roll formers are available for sale and for short-term or long-term lease.

PORTABLE ROLL FORMERS

Page 4: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

ALTERNATIVE SYSTEMS

1 3/4” 1”

16” Coverage 16” Coverage

2” Snap-On BattenOptional Vinyl Weatherseal

24 Gauge Steel SpecificationsUses: Roof, FasciaCoverage: 16”Finishes: SmoothFasteners: ConcealedApplications: Open framing, solid sheathingSeam: 2” wide and 1 3/4” high snap-on batten cap

24 Gauge Steel

SpecificationsUses: Roof, Fascia, MansardCoverage: 11”Finishes: Smooth, optional wood grain textureFasteners: ConcealedApplications: Solid sheathingSeam: 1” seamOptional: Vinyl weatherseal

BATTEN SEAM PANEL BERMUDA ROOF PANEL

SIMULATED TILE ROOF SYSTEMS

BERRIDGE METAL SHINGLES

2”

8” Width 9” Width

24 Gauge Steel SpecificationsUses: RoofCoverage: 8” wide x 16” longFinishes: SmoothFasteners: ConcealedApplications: Open framing, solid sheathingTiles: 8” wide and 2” tallOptional: Custom mixed color palette

SPANISH TILE

1 1/2”

32 11/16” Coverage

24 Gauge Steel SpecificationsUses: RoofCoverage: 32 11/16”Finishes: SmoothFasteners: ExposedApplications: Solid sheathingTiles: 14” step lengths and 1 1/2” tall

S-TILE

CLASSIC & VICTORIAN SHINGLES

9” x 12” Coverage

24 Gauge Steel SpecificationsUses: Roof, Wall, FasciaFinishes: Victorian or Classic embossed patternFasteners: ConcealedApplications: Solid sheathingCoverage: 9” wide and 12” tall

8 1/2” x 11 1/2” Coverage

24 Gauge Steel SpecificationsUses: Walls, Steep Mansards, FasciaFinishes: Lightly textured and scallopedFasteners: ConcealedApplications: Solid sheathingCoverage: 8 1/2” tall and 11 1/2” wide

FISH SCALE SHINGLES

3/8”10” Coverage

24 Gauge Steel SpecificationsUses: Walls, Fascia, Steep MansardsCoverage: 34 1/2” X 10” Finishes: FlutedFasteners: ConcealedApplications: Horizontal over solid wood sheathing

FLUTED FASCIA PANEL

3/8”

8” Coverage

CURVED FLAT SEAM PANELSPECIALTY APPLICATION SYSTEM

24 Gauge Steel SpecificationsUses: FasciaCoverage: 8” Finishes: SmoothFasteners: ConcealedApplications: Curved over solid sheathing

3’ min - 40’ max

14” 14” 14”

Page 5: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

1”

11 5/8” Coverage

24 and 22 Gauge Steel0.032 Aluminum SpecificationsUses: Soffit, Ceiling, Fascia, Screen WallCoverage: 11 5/8”Finishes: Smooth, optional stucco embossFasteners: ConcealedApplications: Vertical over open framing or solid sheathing Pattern: Optional vee-grooves and venting

L-PANEL

5/8”

6” Coverage

24 Gauge Steel

SpecificationsUses: Wall, Soffit, Ceiling, Fascia, Screen Wall, Berridge Fencing SystemCoverage: 6”Finishes: SmoothFasteners: ConcealedApplications: Vertical over open framing or solid sheathing Pattern: Extruded vee-grooves

B-6 PANEL

FASCIA, WALL & SOFFIT SYSTEMS

3/16”

3 5/8” Coverage

24 Gauge Steel

SpecificationsUses: Wall, Soffit, Ceiling, Fascia, Screen Wall, Berridge Fencing SystemCoverage: 3 5/8”Finishes: Smooth, optional wood grain or stucco embossedFasteners: ConcealedApplications: Vertical over open framing or solid sheathing

THIN-LINE PANEL

HR-16 PANEL

7/8”

16” Coverage

24 and 22 Gauge Steel0.032 Aluminum SpecificationsUses: Wall, Fascia, Screen Wall, Berridge Fencing SystemCoverage: 16” Finishes: SmoothFasteners: ConcealedApplications: Vertical on Fencing; horizontal or vertical over open framing or solid sheathing for other usesPattern: 7/8” height and 4” rib with 2” reveal

1/2”

3 7/8” Coverage

24 Gauge Steel

SpecificationsUses: Wall, Soffit, Ceiling, Fascia, Screen Wall, Berridge Fencing SystemCoverage: 3 7/8”Finishes: Stucco embossed, optional wood grainApplications: Vertical over open framing or solid sheathing Fasteners: Concealed

FLUSH SEAM PANEL

7/8”

HS - 8: 8” Coverage

HS-12: 12” Coverage

24 and 22 Gauge Steel0.032 and 0.040 Aluminum SpecificationsUses: Wall, Soffit, Ceiling, Fascia, Screen Wall, Berridge Fencing SystemCoverage: HS-8: 8”; HS-12: 12” Finishes: Standard stucco embossing, optional smooth*Fasteners: ConcealedApplications: Vertical on Fencing; horizontal or vertical over open framing or solid sheathing for other usesPattern: 7/8” H & 5 5/8” (HS-8) or 9 5/8” (HS-12) rib w/ 2” reveal* Limited availability

HS-8 & HS-12 PANEL

9 5/8”

5 5/8”

4”

1 1/8”

3/8”12 3/4” Coverage

24 and 22 Gauge Steel SpecificationsUses: Wall, Soffit, Ceiling, Fascia, Screen Wall, Berridge Fencing SystemCoverage: 12 3/4”Finishes: Smooth, optional wood grainFasteners: ConcealedApplications: Vertical over open framing or solid sheathing Pattern: 4 1/4” between grooves, optional venting

VEE-PANEL

4 1/4”

24 and 22 Gauge Steel0.032 and 0.040 Aluminum SpecificationsUses: Wall, Soffit, Ceiling, Fascia, Screen WallCoverage: FW-1025: 10 1/4”; FW-12: 12”Finishes: Smooth, optional stucco embossFasteners: ConcealedApplications: Vertical over open framing or solid sheathing Pattern: Optional vee-grooves, striations or ventingOptional: Seam lock feature

FW-12 AND FW-1025 PANEL

1 1/2”

10 1/4” Coverage

1 1/2”

12” Coverage

4”

3 7/8”

Page 6: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

7/8”

24 and 16 Gauge Steel

SpecificationsUses: Framing of light-commercial and residential projects

SPACEFRAME24 and 16 GA Steel

Framing members: hat, purlin, channels, cee, zee

LIGHT GAUGE FRAMING

EXPOSED FASTENERS

3/4”36” Coverage

24 and 22 Gauge Steel0.032 and 0.040 Aluminum SpecificationsUses: Roof, Wall, Soffit, Ceiling, Fascia, Sheathing, Screen WallCoverage: 36”Finishes: Smooth corrugatedFasteners: ExposedApplications: Vertical on Roof; vertical or horizontal over open framing or solid sheathing for other uses

1 1/2”36” Coverage

34 2/3” Coverage

24 and 22 Gauge Steel0.032 and 0.040 Aluminum SpecificationsUses: Roof, Wall, Soffit, Ceiling, Fascia, Sheathing, Screen WallCoverage: 32” and 34 2/3”Finishes: Smooth corrugatedFasteners: ExposedApplications: Vertical on Roof; vertical or horizontal over open framing or solid sheathing for other usesOptional: Factory curved for limited applications

32” Coverage7/8”

S-DECK PANELStraight and Curved (limited)

DEEP-DECK PANEL

1 1/4”

36” Coverage

24 and 22 Gauge Steel0.032 Aluminum SpecificationsUses: Roof, Wall, Soffit, Ceiling, Fascia, Mansard, Sheathing, Screen wallCoverage: 36”Finishes: Smooth corrugatedFasteners: ExposedApplications: Vertical on Roof or Mansard; vertical or horizontal over open framing or solid sheathing for other uses

“R” PANEL

“M” PANEL24 and 22 Gauge Steel0.032 Aluminum SpecificationsUses: Roof, Wall, Soffit, Ceiling, Fascia, Mansard, Sheathing, Screen WallCoverage: 36”Finishes: Smooth corrugatedFasteners: ExposedApplications: Vertical on Roof or Mansard; vertical or horizontal over open framing or solid sheathing for other uses

24 Gauge Steel

SpecificationsUses: RoofCoverage: 24”Finishes: Smooth Fasteners: ExposedApplications: Vertical over solid sheathing

DOUBLE-RIB PANEL

1/2”24” Coverage

24 Gauge Steel Spaceframe Components16 Gauge Galvanized Steel Posts

SpecificationsFence Heights: 4’ 2”, 6’ 2”, 8’ 2” and 10’ 2” Panel Widths: Vary by panel choice. Available in seven 24 gauge panels: Vee-Panel, Flush Seam, Thin Line, B-6, HS-8/HS-12, or HR-16 panelFinishes: Vary by panel choiceFasteners: Interlock with concealed fasteners

ARCHITECTURAL PRIVACY FENCE

6”

6”

3/4”

2 ½”

2 ½”

24 and 16 Gauge Steel

SpecificationsUses: Retrofit roof framing system that provides a new design appearance, hides unsightly mechanical equipment and offers watertight integrity.

VANTAGE POINT

2” 7.2”12”

2 2/3” 6” 2 1/2” 3 1/2”

38 1/4” Overall Width

4” 4” 4” 12” 3/4”

38 1/4” Overall Width

Page 7: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

BERRIDGE MATERIALS & COATINGS

Berridge offers 24 Gauge and 22 Gauge Galvalume® steel and 0.032 and 0.040 aluminum in a wide-selection of Kynar 500®/Hylar 5000® finishes on the topside and a backer coating on the bottom. A protective, strippable film is applied to all prefinished material and must be removed prior to installation. Virtually unlimited custom colors are available with a minimum of 5,000 square feet order. Consult BMC for pricing and availability.

All colors applied by Berridge are premium fluoropolymer coatings produced with full strength Kynar 500® /Hylar 5000® resin. Kynar 500®/Hylar 5000® affords maximum exterior durability due to its outstanding resistance to ultraviolet radiation. All colored finishes carry a 20-year warranty against cracking, peeling and fading.

Please consult the BMC Technical department at [email protected] for LEED and Energy Star compliance information. Due to limitations in the printing process, please request actual color chips for accurate color viewing. * Berridge premium and metallic colors require a nominal surcharge.

Natural Metal Finish

Berridge Standard Colors

Teal Green

Bristol BlueColonial Red

Matte Black

Evergreen

Zinc Grey

Burgundy

Cityscape

Hemlock Green

Deep Red

Hartford Green Charcoal Grey

Forest GreenPatina Green

Shasta White

Aged Bronze

Parchment

Dark BronzeCopper Brown Terra-Cotta

Royal Blue

Almond Sierra Tan Buckskin

Medium Bronze

Premium Colors*

Berridge Acrylic-Coated Galvalume® is a coated s h e e t p r o d u c t t h a t combines the corrosion resistance of Galvalume® steel sheet with a clear, organic resin applied to the top side and bottom side of Galvalume® substrate.

Natural White Award Blue

Champagne Copper-Cote™

Antique Copper-Cote

Lead-Cote™ PreweatheredGalvalume®

Acrylic-CoatedGalvalume®

Zinc-Cote™

Metallic Colors*

Finish WarrantiesBerridge offers finish warranties for the Kynar 500®/Hylar 5000® PVDF resin-based coatings, which it applies on its continuous coil coating line. Warranties are issued upon submission and acceptance of a paint finish warranty application within one year of invoice date and payment in full of all material invoices.

Watertightness WarrantiesBerridge offers watertightness warranties on approved Berridge roof assemblies upon submission and acceptance of a watertightness warranty application, approval of installer’s roof installation details, inspection and approval of roof installation and payment in full of all material invoices.

Product ApplicationsFor design assistance and specific product application recommendations, please contact Berridge’s Technical Department at 800-231-8127 or visit www.berridge.com for more information.

APPLICATIONS AND WARRANTIESAIA/CES SeminarsBerridge is registered with the AIA Continuing Education System and is committed to developing quality learning activities in accordance with the CES criteria. Please call Berridge’s Architecture Department at 800-231-8127 for more information about the city-wide, multi-office AIA/CES Seminars.

Installation SeminarsBerridge Roof Installation Training Seminars are one-day sessions conducted by the Watertightness Warranty Department at the Berridge Training Facility in Houston, Texas. The seminar consists of classroom instruction and installation demonstrations using full-scale roof mock-up assemblies and provides in-depth coverage of material handling, underlayment systems, critical installation details for standing seam products and watertight warranty requirements.

SEMINARS

Page 8: BERRIDGE TESTING AND CERTIFICATIONS …€¦ · ASTM E-1680 - Rate of air ... Spanish Tile Roof System n n n n n n S-Tile Roof Panel n n n n n n n n Batten Seam Roof System n n n

* Berridge California and Florida Sales Corporations are separate entities from Berridge Manufacturing Company.

BMC ATLANTA319 Lee Industrial BoulevardAustell, GA 30168(770) 941-5141(770) 941-7344 fax

BMC KANSAS CITY1235 Southwest BoulevardKansas City, KS 66103 (913) 227-0855(210) 650-0379 fax

BMC CHICAGO1175 Carolina DriveW. Chicago, IL 60185(630) 231-7495(630) 231-7520 fax

BMC DENVER7505 E. 41st AvenueDenver, CO 80216(303) 322-3703(303) 322-3810 fax

CORPORATE HEADQUARTERS2610 Harry Wurzbach RoadSan Antonio, TX 78209(210) 650-3050 (210) 650-0379 fax

CORPORATE PRODUCTION FACILITY2201 Rudeloff RoadSeguin, TX 78155(830) 401-5200 (830) 303-0530 fax

CORPORATE TECHNICAL OFFICE1720 Maury StreetHouston, TX 77026(713) 223-4971 (713) 236-9422 [email protected]

BMC OKLAHOMA CITY1400 Exchange AvenueOklahoma City, OK 73108 (405) 248-7404 (210) 650-0379 fax

BMC DALLAS2015 California CrossingDallas, TX 75220(972) 506-8496(972) 506-8478 fax

Technical or Sales Assistance:(800) 669-0009

Follow us on:

www.berridge.com

BMC PHOENIX5717 W. Washington StreetPhoenix, AZ 85043(602) 385-1237(210) 650-0379 fax

BERRIDGE CALIFORNIASALES CORPORATION*8442 Sultana AvenueFontana, CA 92335(562) 402-2081(562) 865-7878 fax

BERRIDGE FLORIDASALES CORPORATION*8802 Venture CoveTampa, FL 33637(813) 335-4505(210) 650-0379 fax

BRANCH OFFICES

BMC HOUSTON1720 Maury StreetHouston, TX 77026(713) 223-4971 (713) 236-9422 fax

BMC SAN ANTONIO6515 Fratt RoadSan Antonio, TX 78218(210) 650-3050(210) 650-0379 fax

Berridge Manufacturing Company is registered with the AIA Continuing Education System (AIA/CES) and is committed to developing quality learning activities in accordance with the CES criteria. Please call Berridge’s Staff Architect at (800) 231-8127 to schedule a seminar.

© Berridge Mini Catalog - 2018 | 10M | Printed in the USA

BMC NORTH CAROLINA1100 Corporation Parkway, Suite 129Raleigh, NC 27610(919) 537-5705(210) 650-0379 fax