Page 1: Behavior - De la Rosa Research - Home
Page 2: Behavior - De la Rosa Research - Home

Stoelting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

ii

Beh

av

ior

ANy-maze ViDEO TRACkiNg SOfTwARE

ANY-maze is a flexible video tracking system designed to automate testing in behavioral experiments. As such it’s ideal for use in studies involving Water-mazes, Plus-mazes, T-maze, Barnes mazes, Light-Dark boxes, Place Preference boxes, Fear Conditioning, Forced Swim, etc. In fact, ANY-maze can be used with almost any type of behavioral testing apparatus and is flexible enough to adapt to new equipment or new testing protocols. Visit ANY-maze.com or ANY-mazeEurope.com for complete details!

60000 ANY-maze

Behavioral Tracking SoftwareANY-maze

 

Download a FREE trial version and see for yourself at ANY-maze.com or ANYmazeEurope.comANY-maze version 4.75 brings a wealth of new and enhanced elements, many of which were developedin response to user requests. New features make ANY-maze even more flexible, while faster analysis and

a host of minor enhancements help ANY-maze maintain its position as the premier system forautomation of behavioral testing.

ANY-maze’s intuitive, friendly design, expansive online help, and all-inclusive technical support make for quick setup and easy use.

ANY-maze has comprehensive reporting and analysis features including more than 30 built-in statistical tests and more than 100 standard measures.

The ANY-maze software mixes simplicity of use with sophisticated capabilities. ANY-maze includes the ability to detect such things as micro-switch closures, photo-beam breaks and lever presses; and can control devices like lamps, shockers, pumps, buzzers, etc.

WOW!

ANY-maze is impressively

flexible, incredibly simple,

and intensely powerful!

Test ANY-maze for Yourself...You’ll Be Astonished by the Features and the Price!

Page 3: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

1

BEh

av

ior

ANY-maze Driven

ANY-boxAutomated Multi-Configuration Behavior Apparatus • Mouse Behavior Tracking Made Easy

ANY-box

Multiple Tests with a Single BaseANY-box is a multi-configuration behavior apparatus designed to automate a range of standard behavioral tests in mice. What sets ANY-box apart is its ability to use the same basic components in many different tests, thus creating a flexible and extremely affordable solution. For example, if you are using your ANY-box as an open field, but want to test animals in the light/dark box, you need only swap out the low-cost inserts.

ANY-box Core and BaseAll ANY-box systems are based on a core consisting of the critically acclaimed ANY-maze software and ANY-maze interface (AMi). The apparatus that sits on an ANY-box base (65101 pictured above) includes a camera to track the animals and a height adjustable infrared photo-beam array to detect rearing behavior. A single core can connect to as many as eight bases, and each base can be used to automate any of the ANY-box behavioral tests.

*The Tests Include:• Open Field • Hole Board• Novel Object Recognition • Light/Dark Box• Conditioned Place Preference

64000

62075

63000

6205565101 ANY-box Base (Includes camera and IR Array)

COmPLete 5-BOx SyStem

65000 ANY-box All-inclusive Automated System,includes all listed tests*

COmPLete INDIvIDuaL autOmateD SyStemS

62000 Automated Open Field, Clear

62050 Automated Open Field, IR Transparent Black

62055 Automated Hole Board

62075 Automated Object Recognition

63000 Automated Light/Dark Box

64000 Automated Conditioned Place Preference

CORe COmPONeNtS

60005 Software/Interface Core (AMi & ANY-box Software)

65101 ANY-box Base (Includes Camera & IR Array)

aNy-BOx INSeRtS

60111 Open Field, Clear—Insert

60122 Open Field, IR Transparent Black—Insert

62020 Object Recognition—Insert

62025 Hole Board—Insert

63100 Light/Dark Box—Insert

64100 Conditioned Place Preference—Insert

visit our wEBsitE for morE dEtails!

Page 4: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

2

BEh

av

ior

WAter MAze

BArNes MAze

rAdiAl ArM MAze

The Radial Arm Maze has been used extensively in evaluating spatial learning and memory. The apparatus consists of eight (or 12) equidistantly-spaced arms radiating from a small circular central platform. The design ensures that, after checking for food at the end of each arm, the rodent is forced to return to the central platform before making another choice. The subject always has eight (or 12) possible options.

The Barnes Maze is similar to the Radial Arm and Morris Water mazes, but without dietary restrictions, and with less physical stress. The Barnes Maze is designed for testing spatial learning and memory. Within the maze, animals are motivated to escape from the brightly lit, open platform to a small dark recessed chamber (escape box). During testing, the animal learns the spatial location of the escape box. The maze also includes false escape boxes, which help remove visual cues that might be observed from a distance or through an open hole.

The Morris Water Maze is a behavioral procedure device designed to test spatial memory. advantages: Elimination of local cues such as trace scents and no fixed-escape formula.

Morris Water Maze

Radial 8-Arm Maze

Barnes Maze

BehAvior MAzesWater Maze · Radial Arm Maze · Barnes Maze · Open Field · Elevated Plus-Maze · Zero-maze

T-maze · Y-maze · Forced Swim · Tail Suspension · Light/Dark · CPP · Hole Board · Novel Object

WateR maze

60135 Water Maze, Mouse, 4 ft Diameter (approx.)

60136 Water Maze, Mouse/Rat, 5 ft Diameter (approx.)

60235 Water Maze, Rat, 6 ft Diameter (approx.)

avaILaBLe ISLaNDS

60030 4 in (10.2 cm) Diameter/12 in (30.5cm) Height

60035 4 in (10.2 cm) Diameter/20 in (50.8cm) Height

8 aRm RaDIaL maze LaNe WIDtH aRm LeNgtH

WaLL HeIgHt

60150 Radial Maze, Mouse 5cm 35cm 9cm

60250 Radial Maze, Rat 10cm 50cm 13cm

12 aRm RaDIaL maze

60155 Radial Maze, Mouse 5cm 35cm 9cm

60255 Radial Maze, Rat 10cm 50cm 13cm

BaRNeS maze taBLe DIa. HOLe DIa. HeIgHt

60170 Barnes Maze, Mouse 91cm 5cm 90cm

60270 Barnes Maze, Rat 122cm 10cm 90cm

Page 5: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

3

BEh

av

ior

elevAted Plus-MAze

t-MAze

elevAted zero-MAze

oPeN Field

The Elevated Plus-Maze is used to assess anxiety-like behavior in laboratory animals. The maze exploits the conflict between the innate fear that rodents have of open areas, versus their desire to explore novel environments.

The Elevated Zero-Maze is a modification of the Elevated Plus-Maze which incorporates both traditional and novel ethological measures in the analysis of anxiety. The design comprises an elevated circular platform with two opposite enclosed quadrants and two open. This removes any ambiguity in interpretation of time spent on the central square of the traditional “plus” design, and allowing uninterrupted exploration.

The T-Maze is used largely in preference and spatial learning tasks. Animals learn to alternate between arms, based on their memory of the previously visited arms, or choose an arm based on the reward pre-sented. The simple, capital T-shape design incorporates a single choice point with only two alternatives.

The Open Field is broadly used to assess exploratory behavior, and is validated for use in the measurement of anxiety-related behaviors. Circular Open Fields are also available. visit StoeltingCo.com or Stoeltingeurope.com

Elevated Plus-Maze

Elevated Zero-Maze

T-Maze

Open Field

BehAvior MAzesWater Maze · Radial Arm Maze · Barnes Maze · Open Field · Elevated Plus-Maze · Zero-maze

T-maze · Y-maze · Forced Swim · Tail Suspension · Light/Dark · CPP · Hole Board · Novel Object

OPeN FIeLD WIDtH DePtH HeIgHt

60100 Open Field, Mouse, Clear Walls 40cm 40cm 35cm

60101 Open Field, Mouse, Gray Walls 40cm 40cm 35cm

60200 Open Field, Rat, Clear Walls 100cm 100cm 35cm

60201 Open Field, Rat, Black Walls 100cm 100cm 35cm

60210 Quad Divider, Black / Divides to four 50 x 50cm enclosures

t- maze LaNe WIDtH

Stem LeNgtH

aRm HeIgHt

aRm LeNgtH

60181 T-Maze, Mouse 5cm 35cm 10cm 28cm

60281 T-Maze, Rat 10cm 50cm 20cm 40cm

eLevateD zeRO-maze DIameteR LaNe WIDtH WaLL HeIgHt Leg HeIgHt

60190 Zero-Maze, Mouse 50cm 5cm 15cm 40cm

60290 Zero-Maze, Rat 100cm 10cm 30cm 40cm

PLuS- maze LaNe WIDtH

aRm LeNgtH

WaLL HeIgHt Leg HeIgHt

60140 Plus-Maze, Mouse 5cm 35cm 15cm 40cm

60240 Plus-Maze, Rat 10cm 50cm 40cm 40cm

Page 6: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

4

BEh

av

ior

sociABilitY APPArAtus

Ideal for the investigation of autism-related behaviors Social approach Resistance to reverse a learned pattern of behavior

the Sociability apparatus (3-Chambered Social test) is most often used to assess Autistic-like behaviors. Shortly after a period of habituation, a mouse’s sociability is determined by evaluating the amount of time the test-mouse spends approaching a wire cage, containing an unfamiliar ‘stranger’ mouse. In the second phase of testing a second unfamiliar mouse is introduced into the Sociability Apparatus. The preference for social novelty is then determined by measuring the amount of time the test mouse spends approaching the chamber containing a new, unfamiliar ‘stranger’ mouse (also restricted to a small wire cage), as compared to time spent in the chamber containing the now-familiar mouse. Resistance to change is measured by two “reversal learning” tasks. testing in the Sociability apparatus can be completely automated by the aNy-maze software system. Order aNy-maze separately, see inside front cover (page ii).

dimEnsionsMain Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60x40x22(h) cm(divided into 3 compartments, each 20cm)

Door Dimension: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5x8 cm ‘Stranger’ Enclosure Diameter: . . . . . . . . . . . . . . . . . . . . . . . . . .7 cmHeight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 cm Bar Diameter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 mmBars Spacing: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 mm

60450

60451

SOCIaBILIty aPPaRatuS

60450 Sociability Cage, clear plexiglass

60451 Additional ”Stranger” Enclosures (wire cages) set of 2, gray

60452 Additional ”Stranger” Enclosures (wire cages) set of 2, white

sociABilitY APPArAtus3-Chambered Social Test for the Assessment of Autistic-like Behaviors

ANY-maze Driven

Page 7: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

5

BEh

av

ior

PArAllel rod Floor APPArAtus

Automated data collection and analysis Uses a specialized version of the ANY-maze software Durable, easy-to-clean Similar cost as Rota-Rod device, but with many more options

the Parallel-Rod Floor apparatus, designed for assessing the effects of drugs, brain damage and disease, on motor coordination and fatigue, is ideal for use with knockout and transgenic mice. The Parallel-Rod Floor Test's high throughput design makes it an extremely versatile and valuable screening and phenotyping tool.

Adapted from the apparatus first described and developed by Drs. Kamens and Crabbe, the Parallel-Rod Floor Test is a new model of ataxia in mice. The Parallel-Rod Floor Test allows for the simultaneous measurement of ataxia and locomotor activity, adding variety to the battery of other tests currently available.

Yields two additional, dependent variables:• Number of errors (foot slips)• Horizontal distance traveled (cm)

Using a ratio (errors per cm traveled x 100) to index ataxia (corrected for individual differences in activity), provides a robust and unique measure of genetic contributions to locomotor incoordination. This is in contrast to several other measures of ataxia, such as the Rota-Rod, where the param-eters of the task (e.g., rate of acceleration of rotation) have been shown to have large effects on the pattern of strain sensitivity.

Software IncludedThe Parallel-Rod Floor Apparatus uses a specialized version of the ANY-maze software to track as many as 16 Parallel-Rod Floor Tests simultaneously.

PaRaLLeL ROD FLOOR aPPaRatuS

61000 Parallel-Rod Floor Apparatus, Single Enclosure System

61500 Parallel-Rod Floor Apparatus, Four Enclosure System

Easier to use than Rota-Rod Automatically records foot-falls Automatically records general activity Ideal for mice

Mouse Motor iNcoordiNAtioN

ANY-maze Driven

Stoelting Parallel-Rod Floor Apparatus

61000 Parallel Rod Floor Apparatus

Call or Email UsAbout a Demonstration

of this Equipmentin Your Laboratory

Page 8: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

6

BEh

av

ior

ANY-maze cage

the aNy-maze cage (amc) is an automated, software-based, observation system for monitoring mouse behavior. The system is ideal for characterizing phenotypic behaviors especially as they relate to home cage activity and circadian rhythms. Using the renowned ANY-maze software, AMc collects continuous data related to:

• movements and spontaneous activity• Home cage activity• Rearing behavior• Diurnal activity• Running wheel activity• Food and water consumption• Sound and light control

Connect up to 8 cages to a single computerThe AMc isolation chamber was designed to help limit external and inter-subject influences such as facility lights and sounds, ultrasonic vocalizations, smells and movements. The chamber is equipped with a ventilation fan and temperature sensor to keep the temperature within the chamber constant and stable.

aNy-maze Cage

67000 ANY-maze Cage (AMc), Mouse

67001 ANY-maze Cage Apparatus (without software)

ANY-maze cage AMc

The built-in infrared (IR) sensitive camera, IR LEDS and ambient light LEDS ensure robust tracking, regardless of ambient light conditions. These LED lights are software set and controlled.

Food and water consumption is determined using independent weight-cell transducersIR arrays to determine rearing behaviorRunning wheel allows for monitoring of exercise activity and provides enrichment

for morE priCing and full produCt information, visit stoEltingCo.Com

ANY-maze Driven

67000 ANY-maze Cage (AMc)

AMc Isolation ChamberLimits External Stimuli

Ideal for Characterizing Phenotypic Behaviors

Page 9: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

7

BEh

av

ior

ANY-maze Driven

ANY-maze FeAr coNditioNiNg

the aNy-maze Fear Conditioning System is a state-of-the-art system for accurately detecting minimal movement, and freezing, associated with fear. A specific version of the ANY-maze software is paired with, and controls, all of the components necessary to conduct Fear Conditioning experiments on mice.

The system uses the two most common fear conditioning paradigms:• Contextual Fear Conditioning• acoustically-Cued Fear Conditioning

Fear conditioning is the method by which animals learn to fear new stimuli. It is a form of learning in which fear is associated with a particular neutral context (e.g. a room) or neutral stimulus (e.g. a tone). This can be done by pairing the neutral stimulus with an aversive stimulus (e.g. a shock). Eventually, the neutral stimulus alone can elicit the state of fear.

SYSTEM FEATURESaNy-maze Software (specific to the Fear Conditioning apparatus) Immobility (fear-induced freezing) quantitatively

measured using video-based detection

Automatically calculates parameters of interest such as:

• Total freezing time

• Number of freezing episodes

• Duration of freezing episodes

• Latency times between stimuli and freezing events

the system includes the following: Fear Conditioning Software (module of ANY-maze)

Camera

Sound Generator

Shocker

Animal Enclosure with electrified-grid floor

Sound-Attenuating Chamber with light and fan

Context Kit (to alter enclosure’s color and texture)

Shocker Constant current (from 0.1 to 2.9 mA in 0.1 mA steps)

Sound generator Two Independent channels with adjustable frequency

and intensity (100-40,000 Hz; 1-150 dB)

Two independent ‘white noise’ channels

ANY-maze driven

enclosure with electrified grid Floor 17 x 17 x 25(h) cm

Convenient and innovative opening and debris tray

Speaker (and light) can be freely positioned within the sound-attenuation chamber

Sound-attenuating Chamber Minimizes travel of ultrasonic vocalizations and

fear-related pheromones

Includes light and fan

Context Kit Includes a set of removable contexts to alter

the animal enclosure’s color and texture

60461S Fear Conditioning System

COmPLete INDIvIDuaL autOmateD SyStemS

60461S Fear Conditioning System, 1 Mouse

60462S Fear Conditioning System, 2 Mice

60463S Fear Conditioning System, 4 Mice

60464S Fear Conditioning System, 1 Rat

60465S Fear Conditioning System, 2 Rats

60466S Fear Conditioning System, 4 Rats

ANY-mazeFeAr coNditioNiNg sYsteM

Page 10: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

8

BEh

av

ior

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

8

BEh

av

ior

the gemINI active and Passive avoidance System was designed specifically to test active and passive avoidance in rats and mice. Unlike many others, GEMINI’s hardware and software have been developed for the sole purpose of avoidance study.

Easy to UseGEMINI’s unique design allows you to run up to 8 independently oper-ated stations directly from your laptop using a standard USB. In addition, by allowing you to define a complete study in advance, GEMINI elimi-nates run-time data entry that could affect the accuracy of your results.

Scrambled Shock Provides More Accurate ResponsesThe GEMINI animal shocker – a solid state feedback-controlled, constant current shocker uses 8 unique outputs to scramble the shock across the grid floor. Scrambling the shock prevents the animal from determining a pattern and leads to more accurate responses.

Kinder, Gentler, Unconditioned StimulusThe Gemini System offers an alternative air puff unconditioned stimulus . This is a kinder and gentler unconditioned stimulus.

geMiNi Active/PAssiveAvoidANce sYsteM

gemINI aCtIve/PaSSIve avOIDaNCe SyStem

57875 Gemini Avoidance System, Shock, Mouse and Rat

57880 Gemini Avoidance System, Shock and Air Puff, Mouse and Rat

57875m Gemini Avoidance System, Shock, Mouse

57880m Gemini Avoidance System, Shock and Air Puff, Mouse only

Configure up to 8 independent avoidance chambers for rapid testing of subjects

Ensure data accuracy by setting up your study in advance

Run the entire system from your laptop or PC using a standard USB port

Deploy continuous testing with independent station starts

Choose an array of cues including non-heating LED house lights, user selectable auditory stimuli, and quiet auto door

Switch between rats and mice in under 5 minutes using interchangeable grid floors

geMiNi Active/PAssive AvoidANce sYsteM

For 220V, add a "V" to the product number8

BEh

av

ior

57875 Gemini Avoidance System

visit our wEBsitE for morE dEtails!

Designed Specifically to Test Active and Passive Avoidance

in Rats and Mice

Page 11: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

9

pain

an

alg

Esia

oroFAciAl PAiN AssessMeNt device (oPAd)

Hot or Cold Temperature Control Objective Pain Assessment Operant Testing and Measures High Throughput Rackable System Up to 16 Cages with a Single Computer 4˚ to 75˚ C Temperature Range Easy to Clean Easy USB Connection Designed for Use with Mice and Rats

the Stoelting OroFacial Pain assessment Device (OPaD) provides an automated measurement of hot or cold orofacial pain assessment in the trigeminal nerve in rats and mice. Using an operant behavior conflict paradigm, rodents voluntarily decide between receiving a reward or escaping an aversive stimulus.

The OPAD begins to work when the animal touches and presses between dual peltier-controlled temperature elements to obtain a liquid reward. As the temperature (hot or cold) becomes aversive, the animal can withdraw. The OroFacial Software will automatically track the number of licks, contact with elements, and amount of liquid consumed.

HardwareThe OPAD cage, for either mice or rats, is seated on a metal base that is easily cleaned. A metal rack is enclosed and can be removed and cleaned between animals. Animals are trained and tested in the cage; the reward bottle is positioned to allow access when simultaneously contacting the thermode with its orofacial region. The metal spout is connected to the data acquisition for recording each lick. In addition,

67500 Orofacial Pain Assessment Device

67500 OPAD(Alternate view)

OROFaCIaL PaIN aSSeSSmeNt DevICe (OPaD)

67500 Orofacial Pain Assessment Device (OPAD)

67501 Orofacial Pain Assessment Device (OPAD),Additional Cages

contact with the thermode will record every touch and duration. Finally the amount (grams) of consumption from the reward bottle is also recorded. Each cage is easily attached to computer via USB port.

SoftwareAll of the data taken from the hardware will then be displayed and analyzed using the OroFacial Software, a module of our popular ANY-maze software. The software will display and track, in real-time, the following events: temperature changes and contacts with the thermode, licks and weight of the reward bottle. Following completion of the test, the OroFacial Software will display graphs and statistical analysis of the experiment(s). Of course, data can be downloaded to other software programs.

oroFAciAl PAiN AssessMeNt deviceoPAd

For 220V, add a "V" to the product number

ANY-maze Driven

Page 12: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

10

pain

an

alg

Esia

PaINless™ is a software-driven, dynamic-force detector ideal for measuring Formalin-induced agitation responses provoked in the Formalin Test.

Software Controlled PAINless™ hardware, combined with user-friendly Windows-based software, allows researchers to conveniently monitor as many as 16 stations simultaneously. The PAINless™ software format displays each subject's responses on the computer screen immediately following each trial. The recording of the results appear in a waveform representing the movement (above a user-defined threshold), on the piezo-electric sensor, when the animal reacts to the injected Formalin. the PaINless™ software captures a complete waveform and provides a method for the researcher to examine the accuracy of the summary point calculations. all raw data from the experiment is captured and combined into one aSCII file for further analysis.

Animal EnclosuresThe PAINless™ animal enclosures are designed to optimally locate the subject without use of restraint. This eliminates potential restraint stress confounds that may affect results. PAINless™ enclosures are configured to focus the source of stimuli on the animal's center.

Parallel Rail StereotaxicAutoMAted ForMAliN test

Ideal for Formalin Test automation

High throughput screening

Easy-to-use with straightforward assembly and menu-driven software

Expands to include 16 test stations

Accommodates Rats, Mice and other small lab animals

“View Wave™” data format for data analysis and validation

Animal isolation cabinets minimize transfer of ultrasonic vocalizations or pheromones among subjects

CE compliant

Independent-contract lab validation

Tightly-coupled sensor system57850 Automated Formalin Test

autOmateD FORmaLIN teSt

57850 PAINless™, Automated Pain Assessment Apparatus, Rat

57851 PAINless™, Automated Pain Assessment Apparatus, Mouse

57855 PAINless™, Additional Units, Rat

57856 PAINless™, Additional Units, Mouse

aNImaL eNCLOSuReS

57860 Sm. Animal Enclosure w/Ultrasensor (15-25g)

57861 Sm./Med. Animal Enclosure w/Ultrasensor (26-60g)

57862 Med. Animal Enclosure (60-200g)

57863 Large Animal Enclosure (201-450g)

57864 X-Large Animal Enclosure (451-800g)

AutoMAted ForMAliN-testPAINless ™ for Scientists

The level of the stimuli remains consistent and the animal is able to turn around and move freely. The cylindrical enclosure also allows movements to be monitored with an ultra-stable, hermetically sealed motion sensor .

for morE priCing and full produCt information, visit stoEltingCo.Com

Page 13: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

11

pain

an

alg

Esia

Pressure APPlicAtioN MeAsureMeNt(PAM)

Joint Painthe new Pressure application measurement (Pam) device is a novel, easy-to-use tool for measuring mechanical pain threshold in experimental joint hypersensitivity models in rodents. The PAM device has been designed and validated specifically for the mechanical stimulation and assessment of joint pain, ideal for detecting arthritis in rats and mice.

OperationThe device is a unique and specialized force sensor that is worn on the thumb of the person doing the testing. Each PAM device comes standard with two force sensors, which have been specifically designed to apply force to rat and mouse joints and pedal switch. Computer software is also included for data acquisition.

Excellent for quantifying:• Joint Sensitivity• Chronic Joint Inflammation• arthritic Pain

Pressure APPlicAtioN MeAsureMeNt (PAM)

58500 Ugo Basile PAM Meter, Mouse and Rat

58500

58500 Ugo Basile PAM Meter, Mouse and Rat

For 220V, add a "V" to the product number

for morE priCing and full produCt information, visit stoEltingCo.Com

Arthritis is associated with chronic, debilitating pain in the joints. Current metrics of arthritic pain are indirect, by scoring the level of motor activity or the animal’s weight distribution (Barton et al. 2007). Current indirect tests, such as the weight distribution correlate well with the level of joint pain, but such a metric is a composite picture of complex pain responses, and provides little discrete information about local stimulation and locally-evoked responses.

The quantification of localized joint hypersensitivity is common in the clinic, but not in animal experiments. In this sense, the new Pam device represents a step forward toward a multifactorial measurement of pain-related behavior in animal research.

The PAM device is the first instrument designed specifically to apply force to the joint and automatically detect the animal’s response.

Instrument ConfigurationPressure transducers: the PAM device comes with 2 different trans-ducers. Each has been tested and validated in the mouse and rat knee joints: small transducer is flat and round (ideal for mouse knee joint), large transducer is flat and round (ideal for rat knee joint).

Page 14: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

12

pain

an

alg

Esia

PAiN AssessMeNt sYsteMs

the Penta 5-in-1 analgesia Complete System can be purchased together or separately. This system includes the Von Frey, Randall Selitto, Plethysmometer, Grip Strength Meter, and Pincher test using only a single electronic control box. Order any of the individual test systems complete and then only the individual modules are needed to connect to the electronic display box to perform each test.

The electronic control box provides the ability to test five different tests simply by moving the connecting the individual instruments to the compact, easy to use, versatile electronic control box. All data is displayed and then stored in the electronics supplied.

5-IN-1 PaIN aSSeSSmeNt SyStem

52730 Penta 5-in-1 Analgesia System

INDIvIDuaL PaIN aSSeSSmeNt SyStemS

52735 Electronic Von Frey Anesthesiometer, Mouse

52736 Electronic Von Frey Anesthesiometer, Rat

52737 Electronic Von Frey Anesthesiometer and 15 Supertips, Mouse

52738 Electronic Von Frey Anesthesiometer and 15 Supertips, Rat

52720 Digital Randall Selitto Test System, Mice and Rats

52791 Electronic Rodent Pincher SystemAnalgesia Meter

52712 Electronic Plethysmometer

52795 Electronic Grip Strength Meter

52735 Electronic Von Frey™ Touch Test

52720 Digital Randall Selitto Test System

52791 Electronic Pincher

52712 Electronic Plethysmometer 52795 Electronic Grip Strength

for morE priCing and full produCt information, visit stoEltingCo.Com

PeNtA 5-iN-1 ANAlgesiA sYsteMFive Different Tests, One Single Control Box

Penta Controller

Page 15: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

13

pain

an

alg

Esia

Parallel Rail StereotaxicPiNPoiNt™

PinPoint™ is a Precision Cortical Impactor™ used in basic medical research to replicate traumatic brain and spinal cord injuries in an animal model. The system is designed to provide the user with precision control, power, and flexibility to generate accurate, reliable, and reproducible results.

Drive MotorThe drive motor is a linear unit consisting of an interconnected motor and ram. During impact, the motor is stationary, while

Microprocessor Controlled Software Interface Velocity (0-6m/s) Depth (0-5mm) Dwell Time (input in milliseconds) Seven Available Tip Sizes Graphical Representation of Impact Integrated Contact Sensor 360˚ Range of Motion

the ram mobilizes. This allows the motor to be of significant strength and durability to propel the ram with more force and power.

Impact TipsThe tips act as the point of contact during impact. They are manufac-tured as round or rectangular for TBI or SCI studies. In addition, the tips are available in seven sizes ranging from 1 to 5mm (tips included). Custom tips are available upon request.

Software InterfacePinPoint™ is operated by a GUI (Graphical User Interface) software package installed on any standard PC or laptop. It is a point-and-click application that allows the user to:

• adjust velocity, depth, and dwell time• Control vertical movements of the ram• Initiate impact• Record important notes• view, save, and export results

51880 PinPoint™ (Stereotaxic not included)

51880 Cortical PinPoint™ Precision Impactor,Stereotaxic mount

corticAl PiNPoiNt™PrecisioN iMPActor

See pages 14-16 for compatible stereotaxics

Page 16: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

14

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

Tips Cuffs Points

Includes the innovative Mouse ear bars

Like the classic Lab Standard™, the NeW Standard Stereotaxic Instrument has larger laser engraved vernier scales (accurate to 100 um), 80 mm of ventral-dorsal, medial-lateral and anterior-posterior travel, absolute lock at 90˚ ventral-dorsal and brass-bushings for electrical grounding. It is available as a digital or motorized model.

But the NEW Standard "design" is what sets it apart:• Revolutionary vertically-adjusting ear and nose bar posts• Revolutionary horizontally-adjusting ear and nose bar posts• Designed for both Rats and mice all on the same base• No u-frame, maximizes operating space• traditional and non-traumatic Rat ear bars

Parallel Rail Stereotaxicthe NeW stANdArd™ stereotAxic tHe NeW StaNDaRD™ SteReOtaxIC

51500 New Standard™ Stereotaxic, Rat and Mouse

51500D Digital New Standard™ Stereotaxic, Rat and Mouse

51500m Motorized New Standard™ Stereotaxic, Rat and Mouse

51501 New Standard™ Stereotaxic, Rat and Mouse (no manipulator arm)

51503 Dual New Standard™ Stereotaxic, Rat and Mouse

51503D Digital Dual New Standard™ Stereotaxic, Rat and Mouse

51503m Motorized Dual New Standard™ Stereotaxic, Rat and Mouse

51500 The NEW Standard™ Stereotaxic Instrument

Includes Mouse and Rat nose adaptor(Mouse adaptor shown above)

Includes dual tip ear bars with tramatic (18˚) and non-tramatic (45˚) ear bars

REVOLUTIONARYNEW DESIGN!

Eliminates U-Frame• Allows greater access to animal• Accommodates animals of all sizes

Page 17: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

15

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

torsJust For Mouse™

stereotAxic iNstruMeNtOur lowest-priced stereotaxic instrument!

51730 Just For Mouse™ Stereotaxic Instrument

Posts adjust vertically

Compact Sizethe Stoelting Just For mouse™ has all the features of the Just for Mice™, but is now more compact by featuring a 10in x 10in (25.4 x 25.4 cm) square base–one of the smallest stereotaxic instruments on the market.

Same Stoelting QualityThe Stoelting Just for Mouse™ Stereotaxic Instrument was specially developed for the explosive growth of research being conducted using knock-out and transgenic mice. Available in your choice of the 51730 Vernier model (100 micron resolution), 51730D, Digital model (10 micron resolution), or 51730M Motorized model (1 micron resolution with computerized Mouse Atlas).

Dual Arm CapableA second manipulator arm can be attached to the base for dual probe placement and/or electrophysiological recordings.

Multiple “Triple-Point” options for securing animal’s head Compact base Dual-arm capable Gas anesthesia compatible

Triple-lead screws for fast positioning

80mm of dorsal-ventral,medial-lateral and anteriorposterior travel

Absolute lock at 90° vertical

• 10 x 10 inch base (25.4 x 25.4 cm)

51730D Digital Just For Mouse™ Stereotaxic Instrument

Parallel Rail StereotaxicJust For Mouse™ stereotAxic iNstruMeNt

INDIvIDuaL PaIN aSSeSSmeNt SyStemS

51730 Just for Mouse™ Stereotaxic Instrument

51733 Dual Just for Mouse™ Stereotaxic Instrument

51730D Digital Just for Mouse™ Stereotaxic Instrument

51730m Motorized Just for Mouse™ Stereotaxic Instrument

51606 Manipulator Arm, 3 Axes, RH, add-on

Dual Arm Capable

Page 18: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

16

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

Low cost Classic design 100 micron Vernier Scale

lAB stANdArd™ For rAts

Motorized movement with StereoDrive Software Digital Atlas with Virtual Probe viewing 1 micron scale

Motorized lAB stANdArd™

Memory of target coordinates Zeroing function at reference point 10 micron Digital Scale

digitAl lAB stANdArd™

the Lab Standard™ Stereotaxic Instrument has been a standard in research labs for nearly five decades. The time-proven U-frame design provides stability and adaptability while the instrument’s exclusive, triple-lead screws allow for smooth, consistent movements with rapid positioning. Perfect for the researcher who needs an inexpensive, versatile and reliable instrument for stereotaxic procedures.

Building on the Classic Lab Standard™ design, our Digital Instrument offers greater speed of operation and increased accuracy. Fit with an easy-to-read digital display and sealed electronic sensors, operation of the instrument is easy and precise. Simply move your probe to an established reference point (e.g. Bregma), zero the LeD display, and move to the desired coordinates.

the motorized Lab Standard™ Stereotaxic combines the classic design of our time-proven ‘U’-Frame with customized motors and state-of-the-art software. Designed to adapt conventional stereotaxic systems, the StereoDrive software allows motorized, computer-controlled stereotaxic positioning in all 3 orthogonal axes. Integrated with popular stereotaxic atlases, the intuitive movement control enables unprecedented accuracy and higher throughput in all stereotaxic applications.

Lab Standard™ Stereotaxic

Digital Lab Standard™ Stereotaxic

Motorized Lab Standard™ Stereotaxic

51600 Lab Standard™ for Rats with 18° Ear Bars

51650 Lab Standard™ for Rats with 45° Ear Bars

lAB stANdArd™ stereotAxic seriesFor Rats and Mice • Classic U-frame Design • Unique Triple-Lead Screws

Interchangeable Adaptors • Gas Anesthesia Compatible • Absolute Lock at 90˚ Vertical

51900 Digital Lab Standard™ for Rats with 18° Ear Bars

51950 Digital Lab Standard™ for Rats with 45° Ear Bars

51700 Motorized Lab Standard™ Stereotaxic., Rat, 18° Ear Bars

51750 Motorized Lab Standard™ Stereotaxic., Rat, 45° Ear Bars

Page 19: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

17

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

Motorized movement with StereoDrive Software Digital Atlas with Virtual Probe viewing 1 micron scale

Motorized coNversioN

Memory of Target Coordinates Zeroing function at reference point 10 micron digital scale

digitAl coNversioN

If you currently own a vernier model stereotaxic you should consider an upgrade. We can upgrade most major stereotaxic brands. Upgrading your existing stereotaxic to a digital model will reduce the risk of human error and increase accuracy (10 rather than 100 micron resolution). The large LED display is also useful for surgeries performed in low-light or constrained environments where reading the vernier scale is difficult.

upgrading to motorized will provide you with automated movement in all 3 orthogonal axes. This movement is integrated, controlled and directed by our innovative software. The software also provides a virtual 3-D map of the brain atlas and displays real time movement of the manipulators and provides a visual marker of a probe’s path through the brain.

Digital Stereotaxic Instrument

Lab Standard™ Stereotaxic

Lab Standard™ Stereotaxic

Motorized Stereotaxic Instrument

uPgrAde oPtioNs AvAilABleTo Learn More About Upgrading Your Current Stereotaxic,visit www.StoeltingCo.com or www.StoeltingEurope.com

51914 Conversion to Digital, 3-axis, Left Hand

51714 Conversion to Motorized, 3-axis, Left Hand

Page 20: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

18

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

MicroMANiPulAtorsUnparalleled Precision and Stability Characterized via Smooth, Drift-Free Movements

MANuAl MANiPulAtor, With JoYstick

hYdrAulic MANuAl MANiPulAtor, 3d

PNeuMAtic iNJector, 15MM trAvel

MANuAl MANiPulAtor, 3d, 3-Axis FiNe coNtrol

Coarse/Fine on the same axis (Coarse 15mm, Fine 5mm) Absorbs vibration from hands by using hydraulic fluid Joystick allows for 3D movements Uses remote control system Compatible with both right- and left-hand use

56120 Manual Manipulator, 3D, 5mm each, with Joystick

56121 Manual Manipulator, 3D 20mm each, with Joystick

56111 Hydraulic Manual Manipulator, 3D with joystick

Smaller internal volume Larger handle to make it easier to hold Easy-to-clean with no spilling Small size, light weight, ergonomic design

56115 Pneumatic Injector, 15mm travel

Leak-free, even when using oil! Coarse movement allows for big travel, up to 30mm each direction Trade-off movement on cartridge results in zero drift

56122 Hydraulic Manual Manipulator, 3D

Sits on firm housing box Operating section sits firmly on table 60mm diameter handles revolve smoothly Introducing lever technique gained 0.2µm scale Compatible with both right- and left-hand use

56103 Manual Manipulator, 3D, 3-axis fine control

56120 (Does not include probe holder)

56115

56122

56103

Page 21: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

19

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

MicroMANiPulAtorsUnparalleled Precision and Stability Characterized via Smooth, Drift-Free Movements

MANuAl MANiPulAtor, 3d, JoYstick

MANuAl MANiPulAtor, 3d, 1-Axis FiNe coNtrol

MANuAl MANiPulAtor, 3d

MANuAl MANiPulAtor, 3d coArse oNlY

Vibration from joystick does not travel to holders Scale on each axis Fine/coarse knobs sit on same axis Compatible with both right- and left-hand use

56105 Manual Manipulator, 3D, joystick

56104 Manual Manipulator, 3D

SPeCIFICatIONS

INCLuDeD B-1 Ball joint, and K-4 Pipette Holder

tRaveLCoarse 25mm/ea.Fine: X/Y/Z 5mm/ea. 500 µm/one-handle revolution

SIze W150mm x D75mm x H170mm

WeIgHt 250g

Compact system with easy-to-use large knobs Knobs on one side allow for easy manipulation Space friendly enables multi-setting Easy access fine/coarse knobs Long 30mm Y/Z axes travel and 25mm X-axis Compatible with use of right or left hand

56106 Manual Manipulator, 3D, 1-axis fine control

56119 Manual Manipulator, 3D, coarse only

SPeCIFICatIONS

INCLuDeD B-1 Ball Joint and K-4 Pipette Holder

tRaveL Coarse X/Y/Z 30mm/ea.

SIze W80mm x D40mm x H75mm

WeIgHt 215g

56105

56104

56106

56119

Page 22: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

20

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

hYdrAulic MANuAl MANiPulAtor, 1d, coMPAct

MANuAl MANiPulAtor, 3d, coMPAct With Built-iN MAgNet

MANuAl MANiPulAtor, 3d oN siNgle Axis

MANuAl MANiPulAtor, 3d, 1-Axis FiNe coNtrol, coMPAct

Precise movement Hydraulic mechanism allows manipulators to be moved remotely and eliminates hand vibration Holding bar comes in 4mm diameter and 8mm diameter Compatible with most manipulators

56108 Hydraulic Manual Manipulator, 1D, compact

Easy and conventional control To be used for multi-settings Compatible with both right- and left-hand use

56107 Manual Manipulator, 3D on single axis

Great for Stereomicroscopes up to x40 magnification Built-in magnet stand allows close proximity to sample Compatible with both right- and left-hand use

56110 Manual Manipulator, 3D, compact with built-in magnet

Firm sliding mechanism All three dimensional knobs located in one position Compact slider for both coarse and fine adjustments Compatible with both right- and left-hand use

56110 Manual Manipulator, 3D, compact with built-in magnet

56126 Manual Manipulator, 3D, 1-axis fine control

56109 Manual Manipulator, 3D, compact

56127 Manual Micromanipulator, 1D, fine/coarse & Yaw/Bow

56124 Manual Manipulator, 1D coarse & Yaw/Bow

56128 Universal Joint, holds one pipette

56130 Hydraulic Manual Manipulator, 3D

SPeCIFICatIONS

INCLuDeD B-2S Ball-joint, and K-4S Pipette holder

tRaveL Fine X/Y/Z 10mmea., Handle 250um/rev. Resolution 1um, Coarse X/Y/Z 15mm each

SIze Control W100mm x D100mm x H115mm, Driven W65mm x D40mm x H98mm

WeIgHt Control 850g, Driven 160g

hYdrAulic MANuAl MANiPulAtor, 3d (iNtegrAted)

MicroMANiPulAtorsUnparalleled Precision and Stability Characterized via Smooth, Drift-Free Movements

56108

56130

56110

56107

56126

Page 23: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

21

stEr

Eota

xiC

s/m

iCro

ma

nip

ula

tors

MANuAl MANiPulAtor, 3d, coMPAct

MANuAl MANiPulAtor, 1d coArse & YAW/BoW

MANuAl MANiPulAtor, 1d FiNe/coArse ANd YAW/BoW

uNiversAl JoiNt, holds oNe PiPette

56109 Manual Manipulator, 3D, compact

SPeCIFICatIONS

INCLuDeD B-2 Ball joint/K-4S Pipette Holder

tRaveL Coarse X/Y/Z 15mm

SIze W50mm x D20mm x H45mm

WeIgHt 65g

56127 Manual Micromanipulator, 1D, fine/coarse & Yaw/Bow

SPeCIFICatIONS

INCLuDeD B-2 Ball joint/K-4S Pipette holder

tRaveL Coarse x 10mm, Fine x 5mm

SIze W50mm x D30mm x H45mm

WeIgHt 48g

56124 Manual Manipulator, 1D coarse & Yaw/Bow

SPeCIFICatIONS

INCLuDeD B-2 Ball Joint/K-4S Pipette Holder

tRaveLCoarse x 15mm, Yaw/Y axis & Bow/Z axis

SIze W40mm x D30mm x H45mm

WeIgHt 43g

Top-locking knob allows for more working space Yaw and Bow capable Direct scale of 30° angle

56128 Universal Joint, holds one pipette

56134 Mini Manual Manipulator, 3D

SPeCIFICatIONS

INCLuDeD B-2 Ball-joint/K-4S Pipette holder

tRaveL Coarse X/Y/Z 15mm

SIze W65mm x D18mm x H65mm

WeIgHt 65g

MiNi MANuAl MANiPulAtor, 3d

MANuAl MANiPulAtor, 3d, 1-Axis FiNe coNtrol, sMAll

56131 Manual Manipulator, 3D, 1-axis fine control

MANuAl MANiPulAtor, 3d, x/Y/z/ coArse coNtrol oNlY

56132 Manual Manipulator, 3D

SPeCIFICatIONS

INCLuDeD B-1 Ball-joint/K-4 Pipette holder

tRaveL Coarse X/Y/Z 30mm

SIze W95mm x D35mm x H110mm

WeIgHt 220g

SPeCIFICatIONS

INCLuDeD B-1 Ball-joint/K-4 Pipette holder

tRaveLFine X5mm, Knob 500um/rev.Coarse X25mm, Y/Z 30mm

SIze W105mm x D35mm x H110mm

WeIgHt 235g

MiNi MANuAl MANiPulAtor, 3d, 1-Axis FiNe coNtrol

56133 Mini Manual Manip., 3D, 1-axis fine control

SPeCIFICatIONS

INCLuDeD B-2 Ball-joint/K-4S Pipette holder

tRaveLFine X5mm, Coarse X10mm, Y/Z 15mm

SIze W70mm x D18mm x H65mm

WeIgHt 69g

MicroMANiPulAtorsUnparalleled Precision and Stability Characterized via Smooth, Drift-Free Movements

56109 56134

56131

56132

56133

56127

56124

56128

Page 24: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

22

un

iqu

E pr

od

uC

ts

BrAiN MicrodiAlYsis ProBes

Use with Rats and Mice Multiple implantations Sturdy metal housing Ready-to-use out of the package—no pre-soaking required

These small probes can be used with Rats and Mice. With a 20kDa molecular cut-off weight they are capable of detecting many of the neuropeptides and neruotransmit-ters in the brain. Each probe has a 2mm or 3mm membrane length with either 5mm or 8mm addition shaft length. Sold in package of 4.Brain Microdialysis Probes

51250 2mm Brain Microdialysis Probe

51250g 8mm Guide Cannula for 51250

51255 3mm Brain Microdialysis Probe

51255g 5mm Guide Cannual for 51255BLue BOx SeNSORS

51260 Nitric Oxide Electrode (each)

51261 Glucose Electrode (each)

51264 Oxygen Electrode, Long-term (up to 12 months) (each)

51265 Oxygen Electrode, Short-term (4-6 weeks) (each)

SPeCIFICatIONS

20,000 Da cut-off weight Outer diameters (OD)

Membrane OD=0.36mm

Microdialysis Probe Shaft OD=0.51mm

Guide Cannula Shaft OD=0.62mm

led coolight illuMiNAtor

59253 Coolight Illuminator, LED, Single Gooseneck

59254 Coolight Illuminator, LED, Dual Gooseneck

59254 LED Coolight IlluminatorSPeCIFICatIONS LeD HaLOgeN

Lifetime 25K hours 200 hours

energy Consumption 53 watts 150 watts

CCt 6K 3,4K

usable Light No UV or IR Emits UV and IR

Light Output 650 lumens 350 lumens

Recurring Cost < $10 $400 annually (lamps and energy use)

The long-life LED source is environmentally and fiscally responsible since it would take 125 replacement bulbs before the LED Coolight would be only at 75% capacity Energy use is just one-third that of a 150W halogen LEDs have almost no infared energy–they are truly a "cool light" source. Halogen lamps transmit IR heat that can damage a sample or specimen

See Page 14 for Our Latest Stereotaxic

Instrument!

BrAiN MicrodiAlYsis ProBesled coolight illuMiNAtor

STEREOTAXIC INSTRUMENTS . . . . . . . . . . . . 1STEREOTAXIC ACCESSORIES . . . . . . . . . . . .12REFERENCE BOOKS . . . . . . . . . . . . . . . . . . . .24SURGICAL SUPPLIES . . . . . . . . . . . . . . . . . . .26AUTOCLAVES/STERILIZERS/ULTRASONIC CLEANERS . . . . . . . . . . . . . . . .34SURGICAL INSTRUMENTS INDEX. . . . . . . . . .36SURGICAL INSTRUMENTS . . . . . . . . . . . . . .37ANESTHESIA. . . . . . . . . . . . . . . . . . . . . . . . . . .50VENTILATORS. . . . . . . . . . . . . . . . . . . . . . . . . .54BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . . .56HISTOLOGY. . . . . . . . . . . . . . . . . . . . . . . . . . . .60METABOLISM & RESPIRATION. . . . . . . . . . . .65PAIN ANALGESIA. . . . . . . . . . . . . . . . . . . . . . .69ANY-MAZE/BEHAVIOR. . . . . . . . . . . . . . . . . .82ELECTROPHYSIOLOGY . . . . . . . . . . . . . . . . .96PUMPS AND PULLERS . . . . . . . . . . . . . . . . 101TUBING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109MICROMANIPULATORS. . . . . . . . . . . . . . . 112

STOE

LTIN

G N

euro

scie

nce

and

Beha

vior

Res

earc

h In

stru

men

ts

ANY-mazeBehavioral Tracking Software

Page 7Just For Mouse Stereotaxic

Expanded Selection of Mazes

Page 84

Complete Line ofGas Anesthesia Products

Page 50

Page 21Full Line of Surgical Supplies

Stoelting Behavior Apparatuses

Page 69

Page 36

Page 91

Page 71

Page 5

Page 88

Motorized Stereotaxic

Multi-ConfigurationBehavior Apparatus

Complete Line ofAnalgesia Instruments

Complete line ofSurgical Instruments

www.StoeltingCo.com | www.StoeltingEurope.com

Your Source for Neuroscience and Behavior Research Instruments

NEW!NEW!NEW!NEW!NEW!NEW!

NEW!NEW!NEW!

Elliptic Lab Standard Stereotaxic

Page 1

ANY-maze Software & Accessories

Page 82

Pricing and Product Information: StoeltingCo.com

620 Wheat LaneWood Dale, IL • 60191 • USA

FORM

04-

10-M

DR S

TOEL

TIN

G/BR

OWN

/60M

Startle ResponseLaboratory (SR-LAB™) System

• Y E A R •

OUR124124124124124124124124124 ththththththththth

PRSRT STDU.S. POSTAGEPAID

STOELTING CO.

Check Out Stoelting's Full-Line Product Catalog.Call or Email [email protected], and ask for your FREE Copy!

Page 25: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

23

un

iqu

E pr

od

uC

ts

Blue Box seNsor

Implantable Microsensors for Analyzing Oxygen, Glucose, and Nitric Oxide in the Brain Micro Size (175-200um diameter) Pre-calibrated Sub-second Resolution Real-time and Continuous Recording In-vivo Stability

Blue Box Sensors can be implanted in the brain by stereotaxic surgery to provide continuous, real-time monitoring of oxygen, glucose or nitric oxide in freely moving, conscious animals.

We can also supply complete systems including hardware and software for data recording and analysis (Contact us for details).

Blue Box Sensor

BLue BOx SeNSORS

51260 Nitric Oxide Electrode (each)

51261 Glucose Electrode (each)

51264 Oxygen Electrode, Long-term (up to 12 months) (each)

51265 Oxygen Electrode, Short-term (4-6 weeks) (each)

SPeCIFICatIONS

SeNSOR DIameteR SeNSItIvIty

Oxygen 200µm 0.1µm

Glucose 175µm 3.5µm

Nitric Oxide 175µm 5.0nm

FEATURESMicro size (175-200µm diameter)Pre-CalibratedSub-second resolutionReal-time & continuous recordingIn vivo stability

Tethered

e-corderPowerStatus

Trigger+

-

Input 1 Input 2 Input 3 Input 4

Channel 1 Channel 2 Channel 3 Channel 4

WE

REAE

QuadStatWE

REAE

WE

REAE

WE

REAE

Pharmacological testingOperant Box MonitoringGeneral activity, sleep/wake

Transmitter

SensorFully implantablePharmacological testingBehavioural testing

Wireless

Implantable microsensors for analyzing O2, Glucose and NO in the brainBlue Box Sensors can be implanted in the brain by stereotaxic surgery to provide continuous, real-time monitoring of oxygen, glucose or nitric oxide in freely moving, conscious animals. We supply complete systems including hardware and software for data recording and analysis.

Responses can be monitored in real-time using either a tethered recordings (all sensors) or wireless recordings (oxygen sensors only).

Sensor Diameter SensitivityOxygen 200µm 0.1µM Glucose 175µm 3.5µM Nitric Oxide 175µm 5.0nM

FEATURESWireless transmitter with sensors attachedWeight 12gm (rat use only)2.4GHz digital transmission100Hz sampling frequencyIn-animal charging

Contact us for more information and detailed specifications

Long Life Oxygen sensor (Øint200µm)

Analyte detecting tip

Wireless transmitter

FEATURESMicro size (175-200µm diameter)Pre-CalibratedSub-second resolutionReal-time & continuous recordingIn vivo stability

Tethered

e-corderPowerStatus

Trigger+

-

Input 1 Input 2 Input 3 Input 4

Channel 1 Channel 2 Channel 3 Channel 4

WE

REAE

QuadStatWE

REAE

WE

REAE

WE

REAE

Pharmacological testingOperant Box MonitoringGeneral activity, sleep/wake

Transmitter

SensorFully implantablePharmacological testingBehavioural testing

Wireless

Implantable microsensors for analyzing O2, Glucose and NO in the brainBlue Box Sensors can be implanted in the brain by stereotaxic surgery to provide continuous, real-time monitoring of oxygen, glucose or nitric oxide in freely moving, conscious animals. We supply complete systems including hardware and software for data recording and analysis.

Responses can be monitored in real-time using either a tethered recordings (all sensors) or wireless recordings (oxygen sensors only).

Sensor Diameter SensitivityOxygen 200µm 0.1µM Glucose 175µm 3.5µM Nitric Oxide 175µm 5.0nM

FEATURESWireless transmitter with sensors attachedWeight 12gm (rat use only)2.4GHz digital transmission100Hz sampling frequencyIn-animal charging

Contact us for more information and detailed specifications

Long Life Oxygen sensor (Øint200µm)

Analyte detecting tip

Wireless transmitter

FEATURESMicro size (175-200µm diameter)Pre-CalibratedSub-second resolutionReal-time & continuous recordingIn vivo stability

Tethered

e-corderPowerStatus

Trigger+

-

Input 1 Input 2 Input 3 Input 4

Channel 1 Channel 2 Channel 3 Channel 4

WE

REAE

QuadStatWE

REAE

WE

REAE

WE

REAE

Pharmacological testingOperant Box MonitoringGeneral activity, sleep/wake

Transmitter

SensorFully implantablePharmacological testingBehavioural testing

Wireless

Implantable microsensors for analyzing O2, Glucose and NO in the brainBlue Box Sensors can be implanted in the brain by stereotaxic surgery to provide continuous, real-time monitoring of oxygen, glucose or nitric oxide in freely moving, conscious animals. We supply complete systems including hardware and software for data recording and analysis.

Responses can be monitored in real-time using either a tethered recordings (all sensors) or wireless recordings (oxygen sensors only).

Sensor Diameter SensitivityOxygen 200µm 0.1µM Glucose 175µm 3.5µM Nitric Oxide 175µm 5.0nM

FEATURESWireless transmitter with sensors attachedWeight 12gm (rat use only)2.4GHz digital transmission100Hz sampling frequencyIn-animal charging

Contact us for more information and detailed specifications

Long Life Oxygen sensor (Øint200µm)

Analyte detecting tip

Wireless transmitter

FEATURESMicro size (175-200µm diameter)Pre-CalibratedSub-second resolutionReal-time & continuous recordingIn vivo stability

Tethered

e-corderPowerStatus

Trigger+

-

Input 1 Input 2 Input 3 Input 4

Channel 1 Channel 2 Channel 3 Channel 4

WE

REAE

QuadStatWE

REAE

WE

REAE

WE

REAE

Pharmacological testingOperant Box MonitoringGeneral activity, sleep/wake

Transmitter

SensorFully implantablePharmacological testingBehavioural testing

Wireless

Implantable microsensors for analyzing O2, Glucose and NO in the brainBlue Box Sensors can be implanted in the brain by stereotaxic surgery to provide continuous, real-time monitoring of oxygen, glucose or nitric oxide in freely moving, conscious animals. We supply complete systems including hardware and software for data recording and analysis.

Responses can be monitored in real-time using either a tethered recordings (all sensors) or wireless recordings (oxygen sensors only).

Sensor Diameter SensitivityOxygen 200µm 0.1µM Glucose 175µm 3.5µM Nitric Oxide 175µm 5.0nM

FEATURESWireless transmitter with sensors attachedWeight 12gm (rat use only)2.4GHz digital transmission100Hz sampling frequencyIn-animal charging

Contact us for more information and detailed specifications

Long Life Oxygen sensor (Øint200µm)

Analyte detecting tip

Wireless transmitter

Wireless System Overview:• Weight 12gm (Rat use only)• 2.4gHz digital transmission• 100Hz sampling frequency• In-animal charging• Pharmacological testing

for morE priCing and full produCt information, visit stoEltingCo.Com

Teathered-System Overview:• Pharmacological testing• Operant box monitoring• general activity, sleep/wake

Wireless Recording System

Tethered Recording System

iMPlANtABle MicroseNsors For ANAlYziNg o², glucose ANd No

Call for Quote:Toll Free U.S. & Canada

1-800-860-9775

Blue Box Sensors

Responses can be monitored in real-time using either tethered recordings (all sensors) or wireless recordings (oxygen sensors only).

Page 26: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

24

un

iqu

E pr

od

uC

ts

MuroMAchi Blood Pressure MoNitor

Use with animals under 10 grams Use with C57 BL6 Mice and colored Mice Use with Zucker Fatty Rats Use with Hamsters (with a leg cuff anesthetic) The only monitor that can be used with Guinea Pigs— even without anesthesia! The only monitor that can be used with OB (diabetic model) Mice

50370 Muromachi Blood Pressure Monitor

50375 Cuff-Pulse Sensor for Mice, 20-50g

50376 Cuff-Pulse Sensor for Mice, 10-20g

50377 Cuff-Pulse Sensor for Rats, 90-210g

50378 Cuff-Pulse Sensor for Rats, 210-350g

50393 Cuff-Pulse Sensor for Rats, 350-500g

50379 Cuff-Pulse Sensor for Rats, 500-800g

50386 Rat Holder, 150-210g

50387 Rat Holder, 210-270g

50388 Rat Holder, 270-350g

50389 Rat Holder, 350-500g

50380 Mouse Holder, 10-20g

50381 Mouse Holder, 20-30g

50382 Mouse Holder, 30-40g

50383 Mouse Holder, 40-50g

50391 Data Collection Software for Windows

For 220V, add a "V" to the product number

Parallel Rail StereotaxicvAgiNAl estrous cYcle MoNitor

The best method of determining proestrus stage

Powerful tool for the improvement of reproduction efficiency

Simple operation

Battery-operated

the Rat vaginal Impedance Checker is designed to obtain precise information to determine the optimum day for mating during the rat estrous cycle.

The electrical impedance of the epithelial cell layer of vaginal mucosa is measured at the frequency of 1 kHz by insertion of the probe into the vagina. In the proestrus stage significantly higher impedance is produced compared to that in the other stages of the estrous cycle. 3 kohm of impedance can be considered a standard for indicating proestrus stage. Measuring range is 0 - 19.9kohm.

The conventional method (vaginal smear method) is a troublesome procedure requiring skill, time and labor.

The Rat Vaginal Impedance Checker is a reliable time and labor-saving device. Operation is so simple a novice can easily use it.

59160 Electronic Vaginal-Estrous Cycle-Monitor, Rat

59161 Mouse Probe (50mm x 3.5mm O.D.)

59162 Replacement Rat Probe (55mm x 4.5mm O.D.)

SPeCIFICatIONS

RaNge 0-19.9 kohm

aCCuRaCy +/- 1% +/- 1 digit

DISPLay LCD

BatteRy 4 Rechargeable Battery (Ni-MH) / 30 hr Battery Life

DImeNSIONS 90W x 135D x 35mmH

WeIgHt Approximately 200g (battery excluded)

Important Notice: The 59160 was developed exclusively for rats. A mouse probe is available, but test results can not be guaranteed.

59160 Electronic Vaginal-Estrous Cycle-Monitor, Rat

•Capable of recording from 1.4g neonatal mice

Blood Pressure MoNitor

estrous cYcle MoNitorNon-Preheating • Non-Invasive

The only Non-Preheating,Non-Invasive Blood PressureMonitor for Mice and Rats

50370 Muromachi Blood Pressure Monitor

Does Not AffectReproduction

or Pregnancy Rates

Page 27: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

25

un

iqu

E pr

od

uC

ts

MuroMAchi Blood Pressure MoNitor

50370 Muromachi Blood Pressure Monitor

50375 Cuff-Pulse Sensor for Mice, 20-50g

50376 Cuff-Pulse Sensor for Mice, 10-20g

50377 Cuff-Pulse Sensor for Rats, 90-210g

50378 Cuff-Pulse Sensor for Rats, 210-350g

50393 Cuff-Pulse Sensor for Rats, 350-500g

50379 Cuff-Pulse Sensor for Rats, 500-800g

50386 Rat Holder, 150-210g

50387 Rat Holder, 210-270g

50388 Rat Holder, 270-350g

50389 Rat Holder, 350-500g

50380 Mouse Holder, 10-20g

50381 Mouse Holder, 20-30g

50382 Mouse Holder, 30-40g

50383 Mouse Holder, 40-50g

50391 Data Collection Software for Windows

For 220V, add a "V" to the product number

•Capable of recording from 1.4g neonatal mice

lABorAtorY eAr tAgAutoMAted Milker

Ear tags are numbered from 1-100 (available up to 999)

Available in 5 colors (1.Red 2.Green 3.Blue 4. Light Blue 5.Black)

Once applied, they cannot be easily removed

Laser-etched number provides durability

Parallel Rail StereotaxiclABorAtorY ANiMAl eAr tAg

56779 Ear Tag, Mouse, 5 Colors (20 each)

56780 Ear Tag, Mouse, Red (Box of 100)

56781 Ear Tag, Mouse, Green (Box of 100)

56782 Ear Tag, Mouse, Blue (Box of 100)

56783 Ear Tag, Mouse, Light Blue (Box of 100)

56784 Ear Tag, Mouse, Black (Box of 100)

56785 Ear Tag, Rat, 5 Colors (20 each)

56786 Ear Tag, Rat, Red (Box of 100)

56787 Ear Tag, Rat, Green (Box of 100)

56788 Ear Tag, Rat, Blue (Box of 100)

56789 Ear Tag, Rat, Light Blue (Box of 100)

56790 Ear Tag, Rat, Black (Box of 100)

56791 Ear Tag Applicator

SPeCIFICatIONS

mateRIaL Numbered Tag: Aluminum/Clasp: Stainless Steel

SIzeMouse: 3.5mm O.D. with 3mm PinRat: 3.5mm O.D. with 5mm Pin

AutoMAted Milker For rAt ANd Mouse

The Automated Milker provides researchers the ability to collectrat/mouse milk directly from the teat. The Milker collects milk fromlactating mothers by alternating negative and atmospheric pressures through two solenoid valves and a vacuum pump attached to a microcomputer.

Environmental pollutants, in particular carcinogenic substances and endocrine disrupting chemicals, are a worldwide concern. Theinfluence that these substances have on babies and their development, through breast or cow milk, is of great concern. The ability to gather milk from rats and mice, widely used experimental animals, will aid in advancement of research in this area.

Ideal for the analysis of breast milk composition

59150 Automated Milker, Rat and Mouse

for morE priCing and full produCt information, visit stoEltingCo.Com

59150 Automated Milker, Rat and Mouse

56791 Ear Tag Applicator

56785 Ear Tag, Rat

Page 28: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

26

un

iqu

E pr

od

uC

ts

accessory Kit includes the safety basket, beakers, beaker positioning cover with rings and beaker lids.

Tank capacity: 2.5 gal (9.51 L) Tank size: 11.5" x 9.5" x 6" (292 x 241 x 152 mm) CSA, TUV & FCC Certified

the Soniclean® Cleaner uses a high frequency transducer that allows the unit to perform quietly. Tiny cavitation bubbles are produced with the higher frequency, allowing the bubbles to penetrate smaller crevices. This results in a powerful quiet ultrasonic cleaner.

seNtrY digitAl ultrAsoNic cleANer

soNicleAN® M250 ultrAsoNic cleANer

soNicleAN® M150 ultrAsoNic cleANer

AccessorY kit/sAFetY BAsket

Tank capacity 1.5 gal (5.7 L) Tank size: 11.5" x 6" x 6" (292 x 152 x 152 mm) CSA, TUV & FCC Certified

50307 Soniclean® Ultrasonic Cleaner

50308 Soniclean® Ultrasonic Cleaner

50307-1 Accessory Kit for 50307

50308-1 Accessory Kit for 50308

50307-5 Speed Clean Cleaning Solution

50307-9 Enzymatic Cleaning Solution

ultrAsoNic cleANers

the Sentry ultrasonic Cleaner is a high efficiency cleaner specially developed to clean surgical instruments. Ultrasonic waves pump micron-sized bubbles into the water. These bubbles fit into the tightest spaces that would be impossible to clean by traditional methods. When the bubbles implode, water hits the instrument at speeds up to 250 mph-a very powerful cleaning action.

High-capacity elongated tank (250 x 150 x 80mm; 9.84L x 5.90W x 3.15H inches) Effective cleaning with optional heat setting Quiet operation Small footprint

58620 Ultrasonic Instrument Cleaner (Only available in 120V)

for morE priCing and full produCt information, visit stoEltingCo.Com

High Efficiency Cleaners Developed Specifically for Surgical Instruments

58620

50307

50308

50307-1 Accessory Kit

Page 29: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | EuropE

27

un

iqu

E pr

od

uC

ts

AutoclAve AutoMAtic sterilizer (ultrAclAve®)

AutoclAve sterilizer (ultrAclAve®)

M3 ultrAFAst AutoMAtic sterilizer

Manual Door Chamber size: 9" x 15" (22.9cm x 38.1cm) UL, CSA and ASME Certified

50285 Autoclave Sterilizer

Fast and easy use for efficient instrument processing Reliability and effectiveness for infection control assurance Four pre-set cycles and two user-programmable cycles Automatic door opens once sterilization process is complete Chamber size: 9" x 15" (22.9cm x 38.1cm) UL, CSA, and ASME Certified

50284 Autoclave Automatic Sterilizer

One-step loading Push-button cycle selection Automatic-opening door Intelligent features monitor water levels for worry-free operation Dries instruments in as quickly as 25 minutes Top fill for convenient access to water reservoir Front reservoir drain with on-board drain tube storage Chamber size: 12.1"L x 7.6"W x 1.6"H (30.7 x 19.3 x 4.1cm) UL, CSA, and ASME Certified

50306 M3 UltraFast Automatic Sterilizer

AutoclAves/sterilizersOur full line of sterilizers addresses all of your important sterilization needs.

In fact, we're sure you'll find a sterilizer that’s just right for your needs.

for morE priCing and full produCt information, visit stoEltingCo.Com

50307

50307-1 Accessory Kit

50284

50285

50306

the m3 ultraFast automatic Sterilizer is everything you need in an autoclave. Sterilize unwrapped instruments and handpieces in just 6 minutes and pouched instruments in just over 10, with the touch of a button. The M3 is the simple, intelligent and fast choice for your sterilization needs, featuring:

Page 30: Behavior - De la Rosa Research - Home

stoElting Co. | www.StoeltingCo.com • Email: [email protected] • Toll Free: 800.860.9775 • Fax: 630.860.9775

28

un

iqu

E pr

od

uC

ts

sPeckFiNder® hd video MicroscoPe

1280 X 1024 resolution 360° range of motion Multiple lens options

the SpeckFINDeR® features a generous 16.5cm (6.5") flat panel display, a magnification range from 1x to 90x, and numerous lighting options. The SpeckFINDER represents the evolution of the common magnifier. mounted on a workspace-friendly articulating arm, the SpeckFINDeR® is a visual imaging system used to see precise details of the objects researchers work with everyday, but also reduce the daily fatigue and limited functionality associated with common workstation microscopes and stereoscopes.

SpeckFINDER® Video Microscope

circulAtiNg WAter heAtiNg sYsteM

Ideal for surgery and recovery Patented Clik-Tite leak-proof connectors Two Pads can run with a single T-Pump Unique flow design provides optimum warming even when folded

this solid state Water Circulating Pump warms to an adjustable, set temperature and circulates water through a therapeutic pad. the Click-tite connector is designed to permit two pads to run with one t-Pump. With pliable polymer on one side, nonwoven fabric on the other, pads are easily wiped down for multiple applications. Unique flow design provides optimum warming even when folded. The unit includes a number of safety features such as a key-operated controller to prevent tampering, over-temperature safety alert and automatic shut off.

Circulating Water Heating System

SPeCKFINDeR® vIDeO mICROSCOPe

50575 SpeckFINDER® HD Video Microscope

50325 T-Pump Water Circulating System

50326 T-Pump Lightweight Pad, 15 x 22in

50329 T-Pump Lightweight Pad, 15 x 22in, Pkg of 20

for morE priCing and full produCt information, visit stoEltingCo.Com

sPeckFiNder® video MicroscoPet-PuMP WAter heAtiNg sYsteM

Other pad sizes available–See our website for details.

Page 31: Behavior - De la Rosa Research - Home

www.StoeltingEurope.com • Email: [email protected] • Phone: +353 1 524 2200 • Fax: +353 1 443 0784 | europe

29

un

iqu

e pr

od

uC

tS

Parallel Rail StereotaxicMiCROwAVE fixATiON SySTEM

Microwave fixation is the method for reliable and rapid fixation of brain tissue. If your research involves protein phosphorylation—no other method compares.

Installation and training Included Air-cooled system—no water needed! All controls are done through the touch-screen panel display Digital settings for power levels Improved safety design—less than 1mW/cm2 CE marked and approved Eliminates the use of other fixation methods such as paraformaldehyde/formalin

The In Vivo Microwave Brain Fixation System is the fastest and most effective known method for halting brain chemical activity. Levels of enzyme-regulated neurotransmitters, and other rapidly-acting metabolic substances in the brain, are stopped at the levels that existed in the living animal, brain size and structure remain virtually unchanged! The In Vivo Microwave Brain Fixation Systems have been used for more than 30 years to help uncover brain activity in rodents not accessible using conventional methods of brain fixation resulting in publications in Science, Nature, and many, many other well known journals.

Now this system is even easier to use, no water system needed.

Call or email with questions, references or further information.

In Vivo Microwave Fixation System

MICrowAVE FIxATIoN SYSTEM

50037 In Vivo Microwave Fixation System, 5kW

MiCROwAVE fixATiON SySTEMThe Ultimate Brain Fixation Method–Focused Microwave Energy

Rapid and Reliable Fixation of Brain Tissue, In Vivo, in Less Than 1 Second!

Installation andTraining Included!

NEWRedesign!

Page 32: Behavior - De la Rosa Research - Home

U.S. & CANADA620 Wheat LaneWood Dale, Illinois 60191U.S.A.

EUROPEGround floor, Hilton House3 Ardee RoadRathmines, Dublin 6IRELAND

Europe