because heating your home should be done naturally. - vaillant · why do you think vaillant is...

12
geoTHERM geoSTOR Why Vaillant? Heat pumps Because heating your home should be done naturally.

Upload: phamthu

Post on 26-May-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

geoTHERM geoSTOR

Why Vaillant?

Heat pumps

Because heating your home should be done naturally.

Why do you think Vaillant is Europe‘s best-known brand in heating? Because we offer every client a customised

energy solution and make every home comfortable? Because we are committed to greater energy efficiency

and renewable energy sources? Or because our trade mark is a hare? That is all true, but it‘s not the whole

story. We believe the reason is: Because Vaillant thinks ahead.

Vaillant heat pump technology 4

Ground source heat pumps 6

Domestic hot water preparation 8

Technical data 9

2 / 3

The Vaillant brand

Vaillant is the brand providing answers for tomorrow’s world.

Ahead of our time since 1874

When Johann Vaillant patented the world‘s first gas bath

boiler for domestic hot water in 1894, twenty years after

becoming established, he started a small revolution. In 1905

he invented the first wall-hung boiler: the Vaillant Geyser,

and in 1930 the first gas-fired water heater with the

characteristic Vaillant design came into being. In 1961 we

introduced the first gas-fired circulation water heater and,

in 1967, the first combined heating and hot water system in

one unit. In 1995 we were able to offer the first in-house

developed wall hung boiler with high efficiency condensing

technology, in 2004 our first mini-CHP, in 2006 the first

self-produced heat pump and in 2010 the unrivalled zeolite

gas heat pump. Vaillant has always had the edge. Because

Vaillant thinks ahead.

Quality made in Germany

The hallmark of the hare is a promise of quality that applies

to every product and service with the Vaillant name. Vaillant

quality is perfection in every detail: We spare no effort in the

design and production, so you can effortlessly operate your

Vaillant system in your home. We manufacture our products

mainly in Germany — for customers around the world.

Our range includes gas, oil and pellet heaters, solar

systems, heat pump systems, the zeolite gas heat pump,

the latest combined heat and power systems for every

application, and also hot water cylinders, gas and electric

water heaters, ventilation systems and programable

controls — to ensure that everything works perfectly.

Because Vaillant thinks ahead.

For today, tomorrow and the future

Research and Development in the Vaillant Group, with over

600 employees, is one of the largest and most creative of

those in our industry. We are particularly focused on

developing new technologies for sustainable energy supply,

including the combination of fossil and renewable sources

of energy in efficient integrated systems and the dual use

of energy in combined heat and power systems. In Germany,

we are currently introducing the world‘s first micro-CHP

system with a gas-burning engine, and we are working on

our first fuel cell heating appliance. This is how we are

shaping the future of heating technology. Vaillant is the

brand providing the right answers to all questions related

to heating, living comfort and new energies. Because

Vaillant thinks ahead.

Heat from outside for inside

There is no more abundant, natural energy than solar

energy, which is stored in the form of heat in the air, in

the ground and in groundwater. This energy is available

everywhere, free of charge; it will never be exhausted and

you can use it all year round to heat your house. Because

even cold air and cold ground still contains a good deal of

heat energy. In fact, every medium whose temperature is

above absolute zero, that is above –273,15 °C, contains heat

energy. And it can never get that cold anywhere on earth!

Energy, a gift from nature

Heat pumps increase the temperature of environmental heat –

you could say they pump it up to a temperature suitable for

heating. To achieve this, you have to supply a quarter of the

required heat energy in the form of electricity, while the

remaining approximately 75 % is free.

Of course, it is also true that the smaller the temperature

difference between the outside heat source and the required

heating energy inside is, the less energy is required to balance

the difference out.

a heat pump work?

How exactly does

4 / 5

Environmental heat

Modern technology from Vaillant

A heat pump operates in a cycle in which a refrigerant with a very

low boiling point circulates and constantly undergoes the four

steps of the cycle. It evaporates and in so doing takes up energy,

and then condenses and in the process releases energy. This is

how it works:

Evaporation. Environmental energy is supplied to the

refrigerant in the evaporator. The coolant changes from

a liquid to a gaseous state.

Compression. The gaseous refrigerant is strongly compressed

by using a compressor. (This requires electrical power.) As gas

automatically heats up if it is compressed, the refrigerant

becomes hot.

Condensing. In the condenser, the hot gaseous refrigerant

gives up its heat to the heating system. Of course, the gas

thus becomes cooler and therefore liquid again.

Expansion. In the expansion valve, the refrigerant is

decompressed, i.e. the overpressure is reduced and the

refrigerant cools down so much that it can again take

up environmental heat.

From ground with probe or flat collector

With a Vaillant heat pump, you can choose your heat source:

Ground heat Is extracted using a geothermal probe that leads

vertically into the ground, or with a ground collector that is horizontally

installed at 1.20 to 1.50 m depth.

Our heat pump technology is proven technology and an efficient system.

Good for the environment, good for you

A heat pump makes you independent from fossil fuels and their

constantly increasing costs, because you use free, inexhaustible

energy of your ground instead of externally supplied energy with

its ever increasing costs. And without even the slightest emissions

arising from heat generation, you will always have a comfortable,

warm home.

Buildings big or small –geothermal heat warms them all.

The ground stores energy for you

Just below the surface of the ground there is enough heat for your

home: solar energy that is stored by the ground. With one of

Vaillant’s ground source heat pumps, you can use this heat just

under the surface very efficiently for heating and domestic water

preparation, not just in new builds, but also in modernisations: the

maximum flow temperature of 62 °C makes possible the trouble-

free use of renewa ble energy in renovated old buildings. Your

installer can tell you whether you are eligible for state funding for

this sustainable use of energy.

The energy source is your home’s own plot of land

To tap your own ground heat source, you require either a geothermal

probe or a horizontal ground collector. For geothermal probes,

all borehole depths regarding local regulations can be provided with

the use of single or double U-pipes inside. The geothermal probe

requires very little space and is very efficient.

A ground collector is installed 20 cm below the frost limit. This is

approximately 1,20 to 1,50 m beneath the ground’s surface. It

comprises a plastic pipe that is arranged in curves and loops,

similar to an underfloor heating system. A ground collector is

cheaper than a geothermal probe but requires a lot of space that

cannot then be built upon.

Claus-Heinrich
Hervorheben

6 / 7

Which heat pump do I need?

At Vaillant, we have the correct ground heat pump for every

requirement, with many different outputs to choose form to ensure

your comfort. For example, you can cool your house passive using

a heat pump. The automatic cooling function uses the lower

temperature of the ground and cools the the living space via the

underfloor heating system without costs for the compressor.

The heat pump that can do everything

The heat pump geoTHERM exclusive is the complete solution for

a single-occupancy house. It extracts energy using a geothermal

probe or a ground collector and supplies heat in the winter, passive

cooling in the summer plus hot water at all times. There is an

integrated hot water cylinder, likewise an auxiliary electric heater

and a weather-compensating controller.

The heat pump with comfort on demand

The heat pump geoTHERM plus also heats a single-occupancy

house using ground heat – and what else it does depends on your

preferences: either it supplies you with hot water the whole year

round, or it provides pleasant passivecooling in the summer.

The successor of the winner in the German consumer association

product test, the geoTHERM plus operates with the highest efficiency.

The heat pump that remains flexible

The heat pump geoTHERM is characterised by multiple possible

applications and the ease with which it can be combined with other

systems. The output range from 6 to 17 kW supplies single and

dual-occupancy houses, while geoTHERMs from 22 kW are the

correct choice for multi-family houses, commercial properties and

other buildings with up to 400 m2 floor space. All can be expanded

with a suitable hot water cylinder to match your requirements.

Vaillant brine/water heat pumps:

– German engineering

– For single to multi-family houses, new builds and

modernisations

– geoTHERM exclusive

with integrated 175 l stainless steel hot water cylinder

and natural cooling function 6, 8 and 10 kW

– geoTHERM plus with hot water cylinder or cooling

function: 6, 8 and 10 kW

– geoTHERM heating heat pump:

6, 8, 10, 14 and 17 kW

– geoTHERM for larger properties:

22, 30, 38 and 46 kW;

cascades up to 92 kW possible

– Up to 17 kW with auxiliary 6 kW electrical heater

– Weather-compensating energy balance controller

with graphical display of the environmental output

– Can be combined with a ventilation system

The heat pump geoTHERM exclusive has

been awarded the red dot design award.

geoTHERM exclusive

Ground source heat pumps

Domestic hot water preparation with heat pumps

A solar hot water cylinder for heat pumps

If you want to combine a heat pump without an integrated

cylinder with a solar system for hot water preparation, then the

best solution is the new solar hot water cylinder for heat pumps,

geoSTOR VIH RW 400 B, because it stores the heat from the heat

pump and the solar system in equal measure. If there is sufficient

solar output in summer, the heat pump can even remain switched

off; the solar system takes over hot water preparation by itself.

Two powerful hot water generators

The double jacket tank geoSTOR VDH 300/2 is both technically and

visually a perfect partner for Vaillant heat pumps without an

integrated hot water cylinder. Its double-jacket storage technology

ensures convenient hot water preparation. The conventional round

cylinder, geoSTOR VIH RW 300, on the other hand, is the right

option for you if you are looking for an economic purchase.

Solar hot water cylinder for heat pumps

geoSTOR VIH RW 400 B

– Bivalent storage technology for use of the energy from

the heat pump and solar system

3,2 m2 heat exchanger surface for HP use

– Magnesium protection anode

Hot water cylinder geoSTOR VDH 300/2:

– Completely stainless steel hot water cylinder

– Quick heating of large water quantities thanks to double

jacket cylinder technology

– Magnesium protection anode

Hot water cylinder geoSTOR VIH RW 300:

– Specially designed for heat pumps

– Corrosion protection through use of internal enamelling and

magnesium protection anode

The natural way to wash, shower and bathe:hot water from environmental energy

Can be combined with geoTHERM heat pumps up to 17 (22) kW

– 1,4 m2 heat exchanger surface for solare use

8 / 9

Technical data geoTHERM

Heat pump geoTHERM plus Unit VWS 62/3 VWS 82/3 VWS 102/3

Heating power B0/W35 kW 6,1 7,8 10,9

Power consumption B0/W35 kW 1,3 1,7 2,2

COP B0/W35 4,7 4,7 4,9

Heating power B0/W55 kW 5,7 7,8 9,7

Power consumption B0/W55 kW 1,9 2,5 3,2

COP B0/W55 3,0 3,1 3,0

Storage capacitiy l 175 175 175

Nominal voltage control circuit 230V/50Hz 230V/50Hz 230V/50Hz

Nominal voltage compressor 400V/50Hz 400V/50Hz 400V/50Hz

Nominal voltage supplementary heating 400V/50Hz 400V/50Hz 400V/50Hz

Max. pressure heating bar 3 3 3

Max. pressure warmwater bar 10 10 10

Temperatur heating (min. / max.) °C 25 / 62 25 / 62 25 / 62

Input temperature (min. / max.) °C -10 / 20 -10 / 20 -10 / 20

Temperature warmwater (min. / max. with supplementary heating) °C 55 / 75 55 / 75 55 / 75

Dimension without packing: Height Width Depth

mm mm mm

1800 600 840

1800 600 840

1800 600 840

Dimension without column: Height Width Depth

mm mm mm

1800 600 650

1800 600 650

1800 600 650

Weight without packing kg 206 214 217

Heat pump geoTHERM Unit VWS 61/3 VWS 81/3 VWS 101/3 VWS 141/3 VWS 171/3

Heating power B0/W35 kW 6,1 7,8 10,9 14,0 17,6

Power consumption B0/W35 kW 1,3 1,7 2,2 3,0 3,6

COP B0/W35 4,7 4,7 4,9 4,7 4,9

Heating power B0/W55 kW 5,7 7,8 9,7 13,1 16,3

Power consumption B0/W55 kW 1,9 2,5 3,2 4,3 5,2

COP B0/W55 3,0 3,1 3,0 3,1 3,2

Nominal voltage control circuit 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz

Nominal voltage compressor 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz

Nominal voltage supplementary heating 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz

Max. pressure heating bar 10 10 10 10 10

Temperatur heating (min. / max.) °C 25 / 62 25 / 62 25 / 62 25 / 62 25 / 62

Input temperature (min. / max.) °C -10 / 20 -10 / 20 -10 / 20 -10 / 20 -10 / 20

Dimension without packing: Height Width Depth

mm mm mm

1200600840

1200600840

1200600840

1200600840

1200600840

Dimension without column: Height Width Depth

mm mm mm

1200600650

1200600650

1200600650

1200600650

1200600650

Weight without packing kg 141 148 152 172 179

Technical data geoTHERM

Heat pump geoTHERM Unit VWS 61/2 VWS 81/2 VWS 101/2 VWS 141/2 VWS 171/2

Heating power (B0W35 dT5 -> EN 14511) kW 5,9 8,0 10,4 13,8 17,3

Power consumption kW 1,4 1,9 2,4 3,2 4,1

COP 4,3 4,3 4,4 4,3 4,3

Heating power (B0W55 dT5 -> EN 14511) kW 5,6 7,3 9,5 13,6 16,1

Power consumption kW 2,1 2,7 3,3 4,6 5,6

COP 2,7 2,8 2,9 2,9 2,9

Nominal voltage control circuit 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz

Nominal voltage compressor 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz

Nominal voltage supplementary heating 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz

Nominal power supplementary heating kW 6 6 6 6 6

Heating circuit nominal flow rate dT 5K l/h 1019 1373 1787 2371 2973

Heating circuit rest pressure head dT 5K mbar 391 340 258 345 313

Heat source circuit nominal flow rate dT 3K l/h 1431 1959 2484 3334 3939

Heat source circuit rest pressure head dT 3K mbar 386 327 272 252 277

Heating circuit outgoing temperature (min. / max.) °C 25 / 62 25 / 62 25 / 62 25 / 62 25 / 62

Heat source circuit input temperature (min. / max.) °C -10 / 20 -10 / 20 -10 / 20 -10 / 20 -10 / 20

Dimensions:

Height without connection mm 1200 1200 1200 1200 1200

Width mm 600 600 600 600 600

Depth mm 840 840 840 840 840

Depth without column mm 650 650 650 650 650

Weight without packaging kg 141 148 152 172 179

Heat pump geoTHERM plus Unit VWS 62/2 VWS 82/2 VWS 102/2

Heating power (B0W35 dT5 -> EN 14511) kW 5,9 8,0 10.4

Power consumption kW 1,4 1,9 2,4

COP 4,3 4,3 4,4

Heating power (B0W55 -> EN 14511) kW 5,6 7,3 9,5

Power consumption kW 2,1 2,7 3,3

COP 2,7 2,8 2,9

Nominal voltage control circuit 230V/50Hz 230V/50Hz 230V/50Hz

Nominal voltage compressor 400V/50Hz 400V/50Hz 400V/50Hz

Nominal voltage supplementary heating 400V/50Hz 400V/50Hz 400V/50Hz

Nominal power supplementary heating kW 6 6 6

Heating circuit nominal flow rate dT 5K l/h 1019 1373 1787

Heating circuit rest pressure head dT 5K mbar 391 340 258

Heat source circuit nominal flow rate dT 3K l/h 1431 1959 2484

Heat source circuit rest pressure head dT 3K mbar 386 327 272

Heating circuit outgoing temperature (min. / max.) °C 25 / 62 25 / 62 25 / 62

Heat source circuit input temperature (min. / max.) °C -10 / 20 -10 / 20 -10 / 20

Integrated Storage water heater capacity l 175 175 175

Integrated Storage water heater max. pressure bar 10 10 10

Max. temperature with heat pump °C 55 55 55

Max. temperature with heat pump + supplementary heating °C 75 75 75

Dimensions:

Height without connection mm 1800 1800 1800

Width mm 600 600 600

Depth mm 840 840 840

Depth without column mm 650 650 650

Weight without packaging kg 206 214 217

10 / 11

Technical data geoTHERM and geoSTOR

Heat pump geoTHERM Unit VWS 220/2 VWS 300/2 VWS 380/2 VWS 460/2

Heating power B0/W35 kW 22,0 29,8 38,3 45,9

Power consumption B0/W35 kW 5,0 6,5 8,5 10,0

COP B0/W35 4,4 4,6 4,5 4,6

Heating power B0/W55 kW 20,3 26,8 36,2 42,5

Power consumption B0/W55 kW 6,6 8,8 11,7 14,1

COP B0/W55 3,1 3,0 3,1 3,0

Nominal voltage control circuit 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz

Nominal voltage compressor 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz

Nominal voltage supplementary heating 400V/50Hz 400V/50Hz 400V/50Hz 400V/50Hz

Max. pressure heating bar 3 3 3 3

Temperatur heating (min. / max.) °C 25 / 62 25 / 62 25 / 62 25 / 62

Input temperature (min. / max.) °C -10 / 20 -10 / 20 -10 / 20 -10 / 20

Dimension without packing: Height Width Depth

mm mm mm

12007601100

12007601100

12007601100

12007601100

Dimension without column: Height Width Depth

mm mm mm

1200760 900

1200760900

1200760 900

1200760 900

Weight without packing kg 326 340 364 387

Domestic hot water storage for heat pumps geoSTOR Unit VIH RW 300 VIH RW 400 B VDH 300/2

Storage water heater actual storage capacity l 285 390 270

Storage water heater max. pressure bar 10 10 10

Storage water heater max. temperature °C 85 85 95

Heating circuit capacity heat exchanger l 17,5 22 85

Heating circuit max. pressure bar 10 10 3

Heating circuit max. temperature °C 110 85 95

Heating circuit heating surface of heat exchanger m² 2,9 — 2,3

Heat exchanger surface solar m² — 1,45 —

Heat exchanger surface heatpump m² — 3,2 —

Hot water continuous performance by 10/45 °C and storage temperature 60 °C

l/10 min 410 220 385

Hot water continuous performance by 10/45 °C and storage temperature 60 °C

kW 14 17 (22) 14

Hot water continuous performance by 10/45 °C and storage temperature 60 °C

l/h 345 345 345

Hydraulic connection heating flow/return R 1 R 1 1/4 R 1

Hydraulic connection cold/hot water R 1 R 1 R 1

Hydraulic connection sanitary circulation R 3/4 R 3/4 R 3/4

Dimensions:

Height without connection mm 1775 1461 1702

Width mm 660 807 650

Depth mm 725 875 698

Depth without column mm 500 650 –

Weight without packaging kg 140 180 115

03/1

4 ·

Su

bjec

t to

alt

erat

ion

Your local partner for Vaillant products:

Vaillant Group International GmbH

Berghauser Str. 40 Germany 42859 Remscheid

Phone: +49 2191 18 - 0 Fax: +49 2191 18 – 3090 [email protected] www.vaillant-export.com

Honkoliini Professional OY Sarankulmankatu 25 33900 Tampere Tel. +358 3 2254900 www.honkoliini.com [email protected]