BDSeries PV DC Moulded Case Circuit Breaker
Welcome to our website for more information:
www.zjbeny.com
3231
DC
Circuit B
reakers
1
2
3
4
5
6
7
8
9
10
Application
Type Instruction
Parameter
Appearance Introduction
BDPV DC Moulded Case Circuit Breaker
Series
BD series PV DC Moulded Case Circuit Breaker (MCCB) are mainly used
in large solar power system, which are applied for solar DC combiner box ,inverter
and DC power distribution cabinet. Rated voltage up to 1000V DC, current up to
630A , with the function of overload protection and short-circuit protection.
- BD 630 4P
125A, 250A400A, 630A
4P
1000V
1000V
Product
CodePole
Rated
Voltage
PV DC Moulded Case Circuit Breaker
Protection
BD series PV DC MCCB
Type
Pole
Max Rated Current Electrical CharacteristicsRated Working Voltage
Rated Current
Rated Insulated Voltage
Rated Impulsed Voltage
1 Min Power Frequency Withstand Voltage
Ultimate Breaking Capacity Run Breaking Capacity
Tripping Type
Control And Indication
Control Mode
Shunt Release (SHT)
Auxiliary Release
Terminal End CoverInterphase Barriers
Service Life/Cycle Operation
Mechanical
Electrical
Size (L x W x H)
Ingress Protection
Installation EnvironmentComply With
Storage Temperature
Manual
MOD
Direct (RHD)
Extended(ERH)
Ue
In(A)
Ui
Uimp
Icu
Ics
3.8 KV
20 KA
15 KA
BD-125 BD-250 BD-400
4P125A
4P250A
4P400A
1000V DC
63/80100/125
1000V DC
125/160200/250
1000V DC
250/300/315350/400
1000V DC
8KV
Thermal Magnetic Type
Optional
Optional
Optional
Optional
Optional
Yes
Yes
14000
5000
150x122x92
All Sides IP40 ,Connection Terminal IP20
BD-630
4P630A
1000V DC
400/500/630
14000
5000
5000
1500
5000
1500
3.8 KV
20 KA
15 KA
3.8 KV
20 KA
15 KA
3.8 KV
20 KA
15 KA
High Short-Circuit/Breaking Capacity
Protection Functions: Overload, Short
circuit , Unfrequent Operation
Rated Voltage up to 1000V DC
Rated Current 125A,250A,400A,630A
IEC60947-2, GB14048-2
Easy Installation
1
2
3
4
5
6
7
8
9
10
Brand
Type
Rated Current
Rated Voltage
Standard Code
Certificate Symbol
Wiring Diagram
Characteristic Curve
Breaking Capacity
Operation Breaking Capacity
Max Rated
Current
165x140x89 258x198x107
IEC60947-2/GB14048.2 -45°C~+70°C
282x282x115
S
Series PV DC Moulded Case Circuit Breaker
Welcome to our website for more information:
BD2
www.zjbeny.com
.005
.001
.002
4.5.7 2 31 03 040201 I/IR
.05
.01
.02
.5
1
.1
.2
5
2
200
20
50
100
10
10000
3600
7200
500
S
1000
2000
5 7 51
最大Max.
最小Min.
Dimensions(mm)
Characteristic Curve
33 34
BD-125 BD-250 BD-400 BD-630Type
Contacts
Wiring graph
Picture
Type Y MCCB Type S MCCBType
14035165
110
89
79
258
153
107
98
198 282
160
115
105
28270
122
30
150
114
92
85
132.5
44 50
194
35
126
BD PV DC Moulded Case Circuit Breaker
Series
BD2 series PV DC Moulded Case Circuit Breaker (MCCB) are mainly
used in large solar power system, which are applied for solar DC combiner box
,inverter and DC power distribution cabinet. Rated voltage up to 1500V DC, current
up to 400A , with the function of overload protection and short-circuit protection.
High Short-Circuit/Breaking Capacity
Protection Functions: Overload, Short
circuit , Unfrequent Operation
Rated Voltage up to 1000V DC
Rated Current 225A, 400A
IEC60947-2, GB14048-2
Easy Installation
1
2
3
4
5
6
7
8
9
10
Brand
Type
Rated Current
Rated Voltage
Standard Code
Certificate Symbol
Wiring Diagram
Characteristic Curve
Breaking Capacity
Operation Breaking Capacity
BD2-225T BD2-400
2P225A
3P400A
1000V DC
80A/100A/125A/160A/200A/225A
250A/300A/350A/400A
1000V DC
3.8 KV
20 KA
15 KA
8500
1500
180x92x87 180x135x87
IEC60947-2/GB14048.2 -45°C~+70°C
- BD2 400 3P
225A400A
2P3P
1000V
1500V
8500
1500
1
2
3
4
5
6
7
8
9
10
3P225A
1500V DC
80A/100A/125A/160A/200A/225A
1500V DC
8KV
1500V DC
1500V DC
258x204x119
4000
1000
8In
BD2-225S
S
36
BD2PV DC Moulded Case Circuit Breaker
Series
Appearance Introduction
Application
Type Instruction
Product
CodePole
Rated
Voltage
PV DC Moulded Case Circuit Breaker
Max Rated
Current
BD2 series PV DC MCCB
Protection
Type
Pole
Max Rated Current Electrical CharacteristicsRated Working Voltage
Rated Current
Rated Insulated Voltage
Rated Impulsed Voltage
1 Min Power Frequency Withstand Voltage
Ultimate Breaking Capacity
Run Breaking Capacity
Tripping Type
Control And Indication
Control Mode
Shunt Release (SHT)
Auxiliary Release
Terminal End CoverInterphase Barriers
Service Life/Cycle Operation
Mechanical
Electrical
Size (L x W x H)
Ingress Protection
Installation Environment
Comply With
Manual
MOD
Direct (RHD)
Extended(ERH)
Ue
In(A)
Ui
Uimp
Icu
Ics
Storage Temperature
Thermal Magnetic Type
All Sides IP40 ,Connection Terminal IP20
Optional
Optional
Optional
Optional
Optional
Yes
Yes
Instantaneous action
Parameter
35
BD2-225T BD2-400 BD2-225S
1 3
2 4+ +
2+
4-
1 3
180
92
87
95
120
159
136
180
8795
121
44
159
258
204
106119
165
70
194
BD2-225T
BD2-400
BD2-225S
.005
.001
.002
4.5.7 2 31 03 040201 I/IR
.05
.01
.02
.5
1
.1
.2
5
2
200
20
50
100
10
10000
3600
7200
500
S
1000
2000
5 7 51
最大Max.
最小Min.
Characteristic Curve
Type
Picture
Contacts
Wiring graph
Dimensions(mm)