bc184 range - dieselgeneratorbc184 range voltages 120v - 600v outputs from 15 - 50 kva features: •...

2
BC184 RANGE Voltages 120V - 600V Outputs from 15 - 50 kVA FEATURES: Self excited control or auxiliary winding to provide sustained short circuit capability Advanced automatic voltage regulator (AVR) control 2/3 pitch winding as standard, to avoid excessive neutral currents Single or two bearing construction with dynamically balanced rotor and sealed-for-life bearings Easy access for installation and maintenance IP23 as standard product profile OPTIONS & ACCESSORIES: Anti Condensation Heaters Air Filters RFI Suppression to EC Standards SX421 or SA465 AVRs for Parallel Operation Quadrature Droop kit for Parallel Operation SA465 AVR with 1% Regulation and 2 Phase Sensing SX421 AVR with improved Regulation 0.5% and 3 Phase Sensing (supplied loose) Marine version (Winding 71, SA465 AVR) BC-184 7/11/02 2:23 pm Page 1

Upload: others

Post on 10-Apr-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BC184 RANGE - DIESELGENERATORBC184 RANGE Voltages 120V - 600V Outputs from 15 - 50 kVA FEATURES: • Self excited control or auxiliary winding to provide sustained short circuitcapability

BC184 RANGEVoltages 120V - 600V

Outputs from 15 - 50 kVA

F E A T U R E S :

• Self excited control or auxiliary winding to provide sustained short circuit

capability

• Advanced automatic voltage regulator (AVR) control

• 2/3 pitch winding as standard, to avoid excessive neutral currents

• Single or two bearing construction with dynamically balanced rotor and

sealed-for-life bearings

• Easy access for installation and maintenance

• IP23 as standard

product prof i le

O P T I O N S & A C C E S S O R I E S :• Anti Condensation Heaters

• Air Filters

• RFI Suppression to EC Standards

• SX421 or SA465 AVRs for Parallel Operation

• Quadrature Droop kit for Parallel Operation

• SA465 AVR with 1% Regulation and 2 Phase Sensing

• SX421 AVR with improved Regulation 0.5% and 3 Phase Sensing (supplied loose)

• Marine version (Winding 71, SA465 AVR)

BC-184 7/11/02 2:23 pm Page 1

Page 2: BC184 RANGE - DIESELGENERATORBC184 RANGE Voltages 120V - 600V Outputs from 15 - 50 kVA FEATURES: • Self excited control or auxiliary winding to provide sustained short circuitcapability

BC184 RANGEproduct prof i le

T Y P I C A L A P P L I C AT I O N S :Combined Heat & PowerParallel OperationBase Load PrimeStandbyRentalTelecommunicationMarine/Offshore

3 Phase Ratings for STAMFORD BC184 Generators

50Hz (1500 rpm)

Rating/AmbientApplication/Temp

RiseVoltage

BCI 184E kVAkW

BCI 184F kVAkW

BCI 184G kVAkW

BCI 184H kVAkW

BCI 184J kVAkW

Base 40ºCContinuous

125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

Base 40ºCContinuous

125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

60Hz (1800 rpm)

22.518.027.522.031.325.037.530.040.032.0

22.518.027.522.031.325.037.530.042.534.0

22.518.027.522.031.325.037.530.040.032.0

NANA29.023.232.526.039.031.241.533.2

NANA29.023.232.526.039.031.244.035.2

NANA29.023.232.526.039.031.241.533.2

NANA30.024.033.026.440.032.042.534.0

NANA30.024.033.026.440.032.045.036.0

NANA30.024.033.026.440.032.042.534.0

27.522.032.526.035.028.044.335.447.337.8

28.823.034.427.537.530.046.937.550.040.0

30.024.035.028.037.530.046.937.550.040.0

NANA33.827.036.329.045.936.749.239.4

NANA35.028.038.331.048.538.852.041.6

NANA37.530.038.831.048.538.852.041.6

NANA34.427.536.929.547.337.850.640.5

NANA35.628.540.032.050.040.053.542.8

NANA38.831.040.032.050.040.053.542.8

380 400 415 380 400 415 380 400 415 416 440 480 416 440 480 416 440 480

1 Phase Ratings for STAMFORD BC184 Generators

50Hz (1500 rpm)

Rating/AmbientApplication/Temp

RiseVoltage

BCI 184E kVAkW

BCI 184F kVAkW

BCI 184G kVAkW

BCI 184H kVAkW

BCI 184J kVAkW

Base 40ºC

Continuous125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

Base 40ºC

Continuous125ºC

Peak 40ºC

Standby 150ºC

Peak 27ºC

Standby 163ºC

60Hz (1800 rpm)

13.010.416.012.818.114.521.717.423.218.6

13.010.416.012.818.114.521.717.423.218.6

13.010.416.012.818.114.521.717.423.218.6

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

14.611.717.213.818.715.023.618.925.020.0

15.312.218.014.419.515.624.619.726.321.0

16.012.818.815.020.316.225.720.627.421.9

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

NANANANANANANANANANA

220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240

NEWAGE International Limited PO Box 17 · Barnack Road · Stamford Lincolnshire · PE9 2NB · EnglandTel.: +44 (0) 17 80 48 40 00 · Fax: + 44 (0) 17 80 48 41 00 e-mail: [email protected] · internet: www.newage-avkseg.com

©Newage International 2002

Due t

o ou

r poli

cy o

f con

tinuo

us im

prov

emen

t, de

tails

in th

is lea

flet w

hich

were

corre