batteries for renewable energy applications · 2 v tubular pbsbsnse san (hb) liquid 30 min – 10 h...
TRANSCRIPT
BAE Secura Solar
Batteries for Renewable Energy Applications
Biomass
Wind
Hydropower
GermanyMade in
Solar
BAE Secura Batteries for Stationary Applications
vented (VLA)
100 – 3,250 Ah
2 V
Tubular PbSbSnSe
SAN (HB)
Liquid
30 min – 10 h
> 3 years
100 % tight
20+
> 1,500
2.23
vented (VLA)
50 – 300 Ah
6 V, 12 V
Tubular PbSbSnSe
SAN (HB)
Liquid
30 min – 10 h
> 3 years
100 % tight
18
> 1,200
2.23
valve regulated (VRLA)
100 – 3,250 Ah
2 V
Tubular PbCaSn
ABS (HB / V-0)
GEL
30 min – 10 h
N/A
100 % tight
20
> 1,500
2.25
OPzV CellsOPzS Block OPzV Block
Applications
System
Nominal capacity (10 h)
Voltage
Positive electrode
Container (UL-94 rating)
Electrolyte
Typical discharge time
Water refilling interval1)
Pole bushing
Service life (years)
Cycles IEC 60896-11/ -21/ -22
Float voltage (V/ cell)
Type OPzS Cells
valve regulated (VRLA)
50 – 900 Ah
2 V, 6 V, 12 V
Tubular PbCaSn
SAN /ABS (HB / V-0)
GEL
30 min – 10 h
N/A
100 % tight
18
> 1,500
2.25
Reference temperature: 20 °C 1) Under nominal conditions, float service
BAE Secura Batteries for Stationary Applications
What makes BAE batteries so reliable …
BAE stationary batteries are used wherever perfect reliable power supply has to be ensured, both for a few seconds and for hours. Typical applications are Uninterrupted Power Supply (UPS) – systems as to be found in data centers, telecommunication installations or hospitals and airports. Fur-ther applications are backup systems used in power plants or industry and infrastructure systems.
BAE stationary batteries are available in low maintenance VLA and maintenance free VRLA-GEL design. For high current appli-cations, batteries with positive grid plates (OGi or OGiV) are used. In applications which require long term discharges and / or high cycle life, batteries with positive tubular plates (OPzS or OPzV) are used. Moreover BAE is able to supply tailor-made solutions.
BAE stationary batteries reflect outstanding quality by:• approved service life of more than 20 years
for cells• fully insulated battery design to ensure
touch protection• excellent deep discharge capability• slidable patented BAE “Panzerpole” for
perfect reliability• external intercell connector design for all
block batteries• easy access for measurements via service
ring and pole screw
vented (VLA)
200 – 2,400 Ah
2 V
Round Grid PbSbSnSe
SAN (HB)
Liquid
5 min – 10 h
> 3 years
100 % tight
20
> 1,200
2.23
vented (VLA)
25 – 900 Ah
2 V, 6 V, 12 V
Round Grid PbSbSnSe
SAN (HB)
Liquid
5 min – 10 h
> 3 years
100 % tight
16
> 1,000
2.23
valve regulated (VRLA)
25 – 900 Ah
2 V, 6 V, 12 V
Round Grid PbCaSn
SAN/ABS (HB / V-0)
GEL
5 min – 10 h
N/A
100 % tight
15
> 800
2.25
OGi Cells OGi Block OGiV Block
BAE Secura Solar Batteries for Renewable Energy Applications
Reference temperature: 20 °C 1) Capacity at 100 h discharge. 2) Reference values. The real water-refilling-interval for vented batteries depends on many factors, e.g. ambient temperature and specific battery operation.
Applications
Type PVS Cells PVS Block PVV Cells PVV Block SunDepot
Technology Vented (VLA) Vented (VLA) Valve regulated (VRLA) Valve regulated (VRLA) Valve regulated (VRLA)
Maintenance Low maintenance Low maintenance Maintenance free Maintenance free Maintenance free
Nominal capacity (C100) 1) 140 – 4,420 Ah 70 – 430 Ah 140 – 4,710 Ah 70 – 1,260 Ah 200 – 420 Ah
Nominal voltage 2 V 12 V, 6 V 2 V 12 V, 6 V 24 V, 48 V
Positive electrode Tubular Low antimony
Tubular Low antimony
Tubular Lead calcium
TubularLead calcium
TubularLead calcium
Container (UL-94 rating) SAN (HB) SAN (HB) ABS (HB/V-O) SAN/ABS (HB/V-O) SAN/ABS (HB/V-O)
Electrolyte Liquid Liquid GEL GEL GEL
Water-refilling-interval 2) Up to 3 years Up to 3 years Maintenance free Maintenance free Maintenance free
Horizontal operation (optional) N/A N/A Yes Yes N/A
Typical discharge time 1 – 240 h 1 – 240 h 1 – 240 h 1 – 240 h 1 – 240 h
Pole bushing 100 % tight 100 % tight 100 % tight 100 % tight 100 % tight
Cycles IEC 60896-11/-21 > 1,500 > 1,200 > 1,500 > 1,500 > 1,500
Cycles IEC 61427 (at 40 °C) > 3,150 > 2,700 > 3,000 > 2,100 > 2,100
Charge voltage at cyclic operation (V/cell) 2.30 – 2.40 2.30 – 2.40 2.30 – 2.40 2.30 – 2.40 2.30 – 2.40
Float voltage at non cyclic operation (V/cell) 2.23 2.23 2.25 2.25 2.25
BAE Secura Solar Batteries for Renewable Energy Applications
Reference temperature: 20 °C1) Capacity at 100 h discharge.2) Reference values. The real water-refilling-interval for vented batteries depends on many factors, e.g. ambient temperature and specific battery operation.
Applications
Type PVS Cells PVS Block PVV Cells PVV Block SunDepot
Technology Vented (VLA) Vented (VLA) Valve regulated (VRLA) Valve regulated (VRLA) Valve regulated (VRLA)
Maintenance Low maintenance Low maintenance Maintenance free Maintenance free Maintenance free
Nominal capacity (C100)1) 140 – 4,420 Ah 70 – 430 Ah 140 – 4,710 Ah 70 – 1,260 Ah 200 – 420 Ah
Nominal voltage 2 V 12 V, 6 V 2 V 12 V, 6 V 24 V, 48 V
Positive electrode TubularLow antimony
TubularLow antimony
TubularLead calcium
Tubular Lead calcium
Tubular Lead calcium
Container (UL-94 rating) SAN (HB) SAN (HB) ABS (HB/V-O) SAN/ABS (HB/V-O) SAN/ABS (HB/V-O)
Electrolyte Liquid Liquid GEL GEL GEL
Water-refilling-interval 2) Up to 3 years Up to 3 years Maintenance free Maintenance free Maintenance free
Horizontal operation (optional) N/A N/A Yes Yes N/A
Typical discharge time 1 – 240 h 1 – 240 h 1 – 240 h 1 – 240 h 1 – 240 h
Pole bushing 100 % tight 100 % tight 100 % tight 100 % tight 100 % tight
Cycles IEC 60896-11/-21 > 1,500 > 1,200 > 1,500 > 1,500 > 1,500
Cycles IEC 61427 (at 40°C) > 3,150 > 2,700 > 3,000 > 2,100 > 2,100
Charge voltage at cyclicoperation (V/cell) 2.30 – 2.40 2.30 – 2.40 2.30 – 2.40 2.30 – 2.40 2.30 – 2.40
Float voltage at non cyclicoperation (V/cell) 2.23 2.23 2.25 2.25 2.25
Quality – Made in Germany
BAE SECURA SOLAR batteries are the perfect and safe choice for the energy supply in renewable energy applica-tions such as photovoltaic power generation, stand-alone photovoltaic systems and hybrid applications. BAE solar batteries meet all requirements of modern renewable energy applications with a very wide range of sizes and different lead acid technologies. Therefore BAE solar batteries have been approved for a wide range of industrial energy sys-tems, even under extreme conditions, as well as in private households, e.g. to increase the content of self-consumed solar energy to a maximum level.
BAE offers for renewable energy applications extreme low maintenance VLA batteries with liquid electrolyte and maintenance free batteries in progressive VRLA-GEL technology with fixed electrolyte. Due to the high cyclic requirements BAE solar batteries with positive tubular plates are the exclusive solution for high life time perfor-mance. Reliability, a superior life-time and excellent deep discharge capabilities are the hallmarks of our batteries. Based on the outstanding characteristics of the single batteries compact and powerful tailor-made solutions are available like the SunDepot for residential applications.
BAE SECURA SOLAR batteries reflect outstanding quality by:• Highest cycle performance approved acc. to IEC 61427
supported by outstanding tubular electrode quality• Excellent charge acceptance with high efficiency
improved by carbon black additives• Best deep discharge capability design with microporous
leaf separator• Perfect reliability and lowest cleaning and reduced
maintenance effort to minimum due to absolute tightpole bushing in BAE Panzerpol design
• Unique external inter-cell connector design for all solarblock batteries secures best energy transfer and pro-vides single cell monitoring
• Safe and long term proven technology• Well-established and cost neutral recycling circuit
BAE Batterien GmBH
Tel.: +49 (0) 30 53001-661 Fax: +49 (0) 30 53001-667 E-mail: [email protected]
BAE Batterien GmbH Wilhelminenhofstraße 69/70 12459 Berlin GERMANY
06/2
016
480
5623
T
echn
ical d
etails
may
be s
ubjec
t to
alter
ation
s.
www.
filus
ch-fi
ore.d
e
Short Profile
Since 1899 BAE stands synonym for quality and reliability in the market for industrial lead-acid batteries. The core business of BAE is the production of stationary batteries, especially wherever electricity needs to flow uninterrupted like in the emergency power supply for data centers, electrical power supply facilities and tele-communication infrastructure. Since many years BAE also operates in the market for renewable energy and provides solutions for a reliable and environmental-friendly electrical power supply. Moreover BAE produces batteries for motive power and railway applications. Nowadays we are an independent medium-sized company with a well-established position in the international battery market. BAE excels in its customer orientation and quality is our hallmark. A highly flexible and process-orientated structure enables us to provide our customers with tailor-made solutions.
Quality
As a well-recognized manufacturer for premium industrial batteries BAE is aware of its responsibilities to customers, its employees, society and environment. The commitment to quality and the fulfilment of the highest environmental standards, which are embedded in our company standards, have led to a certification according to the quality management standard ISO 9001 in 1995 and to the environmental management standard ISO 14001 in 2004. The implementation of a management system for “Occupational Health- and Safety Assessment Series” (OHSAS 18001) in the year 2012 underlines our focus for continuous process improvements. BAE quality management pervades to all areas and the highest quality standards already apply to the selection and procurement of the components which are used in our products. During the dif-ferent production steps the quality of the raw materials, the intermediate products and the actual production procedure will be checked consequently. Critical issues will be checked 100% to ensure that only products of highest quality level will be supplied to our customers.
Environment
As a producer of high quality lead-acid batteries BAE is aware of its responsibilities towards society and environment. Efficient environmental measures prevent emissions and waste products are disposed and recycled directly where possible during the production process. Lead-acid batteries consist of lead, plastic parts and acid of which all components are almost to 100% recyclable. The used lead will be fully reused again as secondary lead and the plastic parts get removed before the process of lead recycling and are prepared for further using such as in the automobile industry. This whole certified and registered recycling process makes the lead-acid battery one of the most environmental friendly energy sources. Besides we established in 2013 an energy management system according to the ISO 50001 standard to improve all of our energy-related processes and prove our company’s responsibility for the environment. Top quality and reliability are the core elements of the success of our products. Our aim is simple: “the chemistry must be right”.
OHSAS 18001
ISO 50001ISO 14001
ISO 9001
/ rjbatt.com.au / 1300 769 282