Page 1: BackGround Papers 245347

Calverley Golf Club

Proposed Golf Range Lighting

Comparison of Comparison of BermBerm Lighting SystemLighting System

Against End Range SystemAgainst End Range System

Presentation by

Neil Johnson

Sports Lighting Manager(UK)

Page 2: BackGround Papers 245347

Golf Range Lighting StandardsGolf Range Lighting Standards

Tees RangeUK LG4 100 Lux 50 LuxVertical At 1m HeightUSA 200 Lux 100 Lux Vertical At 1m Height

Golf Range Lighting General Requirements Golf Range Lighting General Requirements • Ensure that distance markers are clearly visible• Players able to follow the flight of the ball• Glare to participants should be minimised• Shadows on Tees eliminated for both LH & RH players

Page 3: BackGround Papers 245347

To meet the increasing Light Pollution requirements from Sports Lighting, new products have been developed restricting OVERSPILL - GLARE - SKYGLOW whilst still allowing Improved Lighting Specifications and Energy Savings.

Golf Ranges already have an optimum lighting solution in the END RANGE system.

However the requirement to light the flight of the Golf Ball conflicts with Light Pollution specifications & Upward Light is unavoidable.

Consequently: Golf Ranges are labelled as main causes of Light Pollution and often conflict with Planning requirements.

Page 4: BackGround Papers 245347

What is this Light Pollution issue?

Light Pollution is Obtrusive Light. Sky Glow (Direct light into the Night Sky). Overspill (Intrusive light outside the boundary). Glare (Visual disturbance towards onlookers).

A conventional End Range system will produce all of the above.

Page 5: BackGround Papers 245347

Essential Requirements.

• Consider Light Pollution issues at the onset of the Range Design.

• Examine alternative ways to light the Range.

• Ensure proposals explore and include ways to utilise natural screening to alleviate intrusive light and glare.

• Orientate Ranges away from the “Setting Sun” to ensure adequate contrast of Ball against Sky.

Page 6: BackGround Papers 245347

END RANGE LIGHING – Offers the most efficient lighting system for golf ranges. Due to the high floodlight elevations coupled with high intensity floodlights it also produces the most light pollution. The floodlights cannot be screened, therefore, Glare, Upward Light & Light Trespass is extreme. NOT SUITABLE FOR CALVERLEY GOLF RANGE

Page 7: BackGround Papers 245347

SIDE LIGHTING - Offers good upward light control but is not suitable for applications when housing is below the range looking up into the floodlights. NOT SUITABLE FOR CALVERLEY GOLF RANGE

Page 8: BackGround Papers 245347

BERM LIGHTING - Floodlights at ground level are easily screened, reducing glare & light trespass into properties. Halo effect is significantly reduced when compared to END RANGE LIGHTING. IDEALLY SUITED FOR CALVERLY GOLF RANGE.

Page 9: BackGround Papers 245347

Comparison of END Range & BERM Systems. Both Ranges with 4m edge screening.

Page 10: BackGround Papers 245347

Installation Comparisons. Based upon a typical 40 Bay Range.

Lighting System

Light Pollution Control

Lighting Level (Lux)

Installed Cost

(approx)

£8K

BERM Good 24 x 400W SON-T 50 Lux £22K

Floodlight & Lamp Type

END RANGE Poor 9 x 1000W SON-T 50 Lux

Energy Consumption similar between the systems.

Both put a similar amount of Light into the Sky. but the Halo EffectHalo Effect differs greatly.

Berm Lighting effectively controls Overspill & Glare.

Page 11: BackGround Papers 245347

b) Provide a clear indication of achieved Lighting Levels (Lux).

To Meet Planning Requirements.a) Aim to achieve ILE Obtrusive Light Recommendations.

Page 12: BackGround Papers 245347

C) Provide Overspill (Intrusive Light) Plots.

Page 13: BackGround Papers 245347

d) Provide a System Demonstration to reduce concerns regarding local environmental impact.e) Provide clear indication of method employed to reduce environmental impact.

f) Provide successful case study if available.

Page 14: BackGround Papers 245347

CALVERLY GOLF CLUB VISUALISATIONCALVERLY GOLF CLUB VISUALISATION

BERM LIGHTING SYSTEMBERM LIGHTING SYSTEM

Page 15: BackGround Papers 245347
Page 16: BackGround Papers 245347
Page 17: BackGround Papers 245347
Page 18: BackGround Papers 245347
Page 19: BackGround Papers 245347
Page 20: BackGround Papers 245347
Page 21: BackGround Papers 245347
Page 22: BackGround Papers 245347
Page 23: BackGround Papers 245347
Page 24: BackGround Papers 245347
Page 25: BackGround Papers 245347

CALVERLY GOLF CLUB VISUALISATIONCALVERLY GOLF CLUB VISUALISATION

END RANGE LIGHTING SYSTEMEND RANGE LIGHTING SYSTEM

Page 26: BackGround Papers 245347
Page 27: BackGround Papers 245347
Page 28: BackGround Papers 245347
Page 29: BackGround Papers 245347
Page 30: BackGround Papers 245347
Page 31: BackGround Papers 245347
Page 32: BackGround Papers 245347
Page 33: BackGround Papers 245347