Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
1.27mm PitchB2B® SMT Connector19.05mm Mated Height
SIGNAL INTEGRITYSIMULATION AND MODELING
Rev. 0
www.advanced.com
![Page 2: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/2.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
Signal Integrity Data ReportingSignal Integrity Data Reporting
At Advanced Interconnections Corporation, our Signal Integrity reporting method differs
dramatically from the common industry practice of isolating the aggressor and victim
terminals from each other by introducing dedicated ground terminals between them. We
believe this method represents a theoretical, best-case, scenario that does not serve the
needs of most systems engineers and circuit designers. An unrealistic number of
connector terminals must be assigned to ground in order to achieve this scenario.
Our standard reporting practice is closely aligned with the decision-making processes of
most systems engineers and circuit designers. The reported data addresses our
customers I/O assignments (net-list) and helps them determine where to best run high-
versus-low frequency signals through our connectors. As such, our reporting method
represents a more practical net-list scenario. Utilizing our unbiased SPICETM and IBISTM
files, system designers are able to create and/or debug their net-list quickly and
accurately.
![Page 3: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/3.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
SI Test & Measurement StudySI Test & Measurement Study
SI Test Setup• The 19.05 mm B2B was measured from 50 MHz to 20.05
GHz.
• A pin-out of 3 rows and 4 columns was assigned from a 3x4
array: S1+
S1-
De-embedded
Waveguide Ports
Leads added to stabilize signal
launch were de-embedded
GND GND GND GND
S1+ S1- S2+ S2-
GND GND GND GND
![Page 4: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/4.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
Performance Results• The test and measurement tasks were completed and the recommended Operational
Bandwidth for the Socket Adapter System is as follows:
Differential: DC to 1.4 GHz @ -15dB and ~ 0.9 to 1.5 Gbit/sec.
Differential: DC to 2.2 GHz @ -10dB and ~ 1.4 to 2.4 Gbit/sec.
Single-ended: DC to 1.6 GHz @ -15dB and ~ 1.0 to 1.7 Gbit/sec.
Single-ended: DC to 2.5 GHz @ -10dB and ~ 1.6 to 2.7 Gbit/sec.
SI Test & Measurement StudySI Test & Measurement Study
![Page 5: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/5.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
SI Test & Measurement StudySI Test & Measurement StudyPerformance Results – continued
(S4,4)-0.5dB @ 1.6 GHz -1.1dB @ 2.4 GHz
(S3,3)-15.0dB @ 1.6 GHz-10.0dB @ 2.4 GHz
Single-ended(Terminals S1-)
(S2,2)- 0.4dB @ 1.6 GHz- 1.0dB @ 2.5 GHz
(S1,1)-15.0dB @ 1.6 GHz-10.0dB @ 2.5 GHz
Single-ended(Terminals S1+)
(S2,1)-0.2dB @ 1.4 GHz-0.6dB @ 2.2 GHz
(S1,1)-15.0dB @ 1.4 GHz-10.0dB @ 2.2 GHz
Differential(Terminals S1+, S1-)
Insertion Loss(Sφφφφ,ß)
Return Loss (Sωωωω,θθθθ))))
Zo @ 100 psec
(10-90%)
Zo @ 200 psec(10-90%)
48.5Ω
55.5Ω
86.0Ω
49.3Ω
53.0Ω
91.5Ω
![Page 6: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/6.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
SI Test & Measurement StudySI Test & Measurement Study
Performance Results– continued
Single-ended(Terminals S1-)
Differential(Terminals S1+, S1-)
12.3%
4.5%
NeXT@ 100 psec
(10-90%)
9.1%
3.5%
NeXT@ 200 psec
(10-90%)
1.0%
1.0%
FeXT@ 100 psec
(10-90%)
0.5%
0.9%
FeXT@ 200 psec
(10-90%)
![Page 7: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/7.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
SI Test & Measurement StudySI Test & Measurement Study
Performance Results– continued
Peak-to-Peak Jitter = 2 psecEye-Closure = 10%
Peak-to-Peak Jitter = 2 psecEye-Closure = 6%
Eye-Diagram @ 5 Gbit/sec
Peak-to-Peak Jitter = 5 psecEye-Closure = 12%
Single-ended(Terminals S1-)
Peak-to-Peak Jitter = 4 psecEye-Closure = 8%
Differential(Terminals S1+, S1-)
Eye-Diagram @ 5 Gbit/sec
with 6 Gbit/sec Aggressor
![Page 8: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/8.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
1 2 3 40 5
-40
-30
-20
-10
-50
0
freq, GHz
dB
(S(1
,1))
dB
(S(2
,2))
Differential Return LossDifferential Return Loss
Plot Range: DC to 5 GHz
(S1,1)-15dB @ 1.4 GHz -10dB @ 2.2 GHz
![Page 9: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/9.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
1 2 3 40 5
-4
-3
-2
-1
-5
0
fre q, GHz
dB
(S(2
,1))
Differential Insertion LossDifferential Insertion Loss
Plot Range: DC to 5 GHz
(S2,1)-0.2dB @ 1.4 GHz-0.6dB @ 2.2 GHz
![Page 10: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/10.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
1 2 3 40 5
-40
-30
-20
-10
-50
0
freq, GHz
dB
(S(1
,1))
dB
(S(2
,2))
Single-ended Return Loss for S1+ & S1-Single-ended Return Loss for S1+ & S1-
Plot Range: DC to 5 GHz
(S1,1) and (S2,2) -15.0dB @ 1.6 GHz -10.0dB @ 2.5 GHz
![Page 11: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/11.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
Single-ended Insertion Loss for S1+ & S1-Single-ended Insertion Loss for S1+ & S1-
Plot Range: DC to 5 GHz
(S1+)
-0.4dB @ 1.6 GHz
-1.0dB @ 2.5 GHz
1 2 3 40 5
-4
-3
-2
-1
-5
0
fre q, GHz
dB
(S(4
,3))
(S1-)
-0.5dB @ 1.6 GH
-1.1dB @ 2.4 GHz
![Page 12: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/12.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.80.0 2.0
70
80
90
100
60
110
time , ns e c
zs
dif
fDifferential Impedance ProfileDifferential Impedance Profile
100ps risetime (10-90%)
86.0Ω
![Page 13: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/13.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.80.0 2.0
85
90
95
100
80
105
time , ns e c
zs
dif
fDifferential Impedance ProfileDifferential Impedance Profile
200ps risetime (10-90%)
91.5Ω
![Page 14: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/14.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.80.0 2.0
40
50
60
30
70
time , ns e c
zs
nz
sp
Simultaneous Plots at 100 psec risetime (10-90%)
S1+ (Zsp Edge Terminals) vs. S1- (Zsn Interior Terminals)
Single-ended Impedance Profile for S1+ & S1-Single-ended Impedance Profile for S1+ & S1-
48.5Ω
55.5Ω
![Page 15: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/15.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.80.0 2.0
45
50
55
40
60
time, nsec
zsp
zsn
Simultaneous Plots at 200 psec risetime (10-90%)
S1+ (Zsp Edge Terminals) vs. S1- (Zsn Interior Terminals)
Single-ended Impedance Profile for S1+ & S1-Single-ended Impedance Profile for S1+ & S1-
49.3Ω
53.0Ω
![Page 16: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/16.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
-4
-3
-2
-1
0
-5
1
time , nse c
10
0*(
xn
ep
-xn
en
)
Differential Near-end Crosstalk (NeXT)Differential Near-end Crosstalk (NeXT)
Percent Differential NeXT @ 100ps risetime (10-90%)
4.5%
![Page 17: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/17.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
-3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
-3.5
0.5
time , nse c
10
0*(
xn
ep
-xn
en
)
Differential Near-end Crosstalk (NeXT)Differential Near-end Crosstalk (NeXT)
Percent Differential NeXT @ 200ps risetime (10-90%)
3.5%
![Page 18: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/18.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
-1.0
-0.8
-0.6
-0.4
-0.2
0.0
-1.2
0.2
time , nse c
10
0*(
xfe
p-x
fen
)Percent Differential FeXT @ 100ps risetime (10-90%)
Differential Far-end Crosstalk (FeXT)Differential Far-end Crosstalk (FeXT)
1.0%
![Page 19: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/19.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0.0
-0.9
0.1
time , nse c
10
0*(
xfe
p-x
fen
)Percent Differential FeXT @ 200ps risetime (10-90%)
Differential Far-end Crosstalk (FeXT)Differential Far-end Crosstalk (FeXT)
0.85%
![Page 20: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/20.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
2
4
6
8
10
12
0
14
time , nse c
10
0*(
xn
e)
Single-ended Near-end Crosstalk (NeXT)Single-ended Near-end Crosstalk (NeXT)
12.3%
Percent Single-ended NeXT @ 100ps risetime (10-90%)
![Page 21: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/21.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
2
4
6
8
0
10
time , nse c
10
0*(
xn
e)
Single-ended Near-end Crosstalk (NeXT)Single-ended Near-end Crosstalk (NeXT)
Percent Single-ended NeXT @ 200ps risetime (10-90%)
9.1%
![Page 22: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/22.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
-1.0
-0.8
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-1.2
0.8
time , nse c
10
0*(
xfe
)
Single-ended Far-end Crosstalk (FeXT)Single-ended Far-end Crosstalk (FeXT)
Percent Single-ended FeXT @ 100ps risetime (10-90%)
1.0%
![Page 23: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/23.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.90.0 1.0
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
-0.5
0.3
time , nse c
10
0*(
xfe
)
Single-ended Far-end Crosstalk (FeXT)Single-ended Far-end Crosstalk (FeXT)
Percent Single-ended FeXT @ 200ps risetime (10-90%)
0.45%
![Page 24: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/24.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
50 100 150 200 250 300 350 4000 450
-0.4
-0.2
0.0
0.2
0.4
-0.6
0.6
time , ps e c
ey
e(v
ou
tp-v
ou
tn,
2.5
e9
)Eye Opening @ 5 Gbit/sec.
Differential Eye-DiagramDifferential Eye-Diagram
Peak-to-peak jitter is 2 psec and Eye-Closure is 6%
![Page 25: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/25.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
Eye Opening @ 5 Gbit/sec with a 6 Gbit/sec Aggressor
Differential Eye-Diagram w/AggressorDifferential Eye-Diagram w/Aggressor
Peak-to-peak jitter is 4 psec and Eye-Closure is 8%
0 50 100 150 200 250 300 350 400-50 450
-0.4
-0.2
0.0
0.2
0.4
-0.6
0.6
time , ps ec
ey
e(v
ou
tp-v
ou
tn,
2.5
e9
)
±175mV
@ 100psec
Data Mask
![Page 26: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/26.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
50 100 150 200 250 300 350 4000 450
0.0
0.1
0.2
0.3
0.4
0.5
-0.1
0.6
time , ps e c
ey
e(v
ou
tp,
2.5
e9
)Eye Opening @ 5 Gbit/sec.
Single-ended Eye-DiagramSingle-ended Eye-Diagram
Peak-to-peak jitter is 2 psec and Eye-Closure is 10%
![Page 27: B2B SMT Connectors Signal Integrity Simulation and Modeling Presentation … · 2012. 5. 7. · Advanced Interconnections Corp. 5 Energy Way, West Warwick, RI 02893 USA 401.823.5200](https://reader034.vdocuments.us/reader034/viewer/2022052002/6014a16fc7655e44c202e046/html5/thumbnails/27.jpg)
Advanced Interconnections Corp.
5 Energy Way, West Warwick, RI 02893 USA401.823.5200 • 800.424.9850 • Fax: 401.823.8723
Product covered by patents issued and/or pending. Data subject to change without notice. Rev. 0
Eye Opening @ 5 Gbit/sec with a 6 Gbit/sec Aggressor
Single-ended Eye-Diagram w/AggressorSingle-ended Eye-Diagram w/Aggressor
Peak-to-peak jitter is 5 psec and Eye-Closure is 12%
0 50 100 150 200 250 300 350 400-50 450
0.0
0.1
0.2
0.3
0.4
0.5
-0.1
0.6
time , ps e c
ey
e(v
ou
tp,
2.5
e9
)
±125mV
@ 140psec
Data Mask