awa - 25 awa - 25/tdf awa - 50/tdf awa-turbo ......awa - 50 twin awa - 50 awa-50 tdf every project...

6
ENGINEERED SERVICE SOLUTION MOBILE COMPRESSED AIR SYSTEM

Upload: others

Post on 27-Jan-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

  • ENGINEERED SERVICE SOLUTION

    MOBILECOMPRESSED AIR SYSTEM

    MARKCO-AWAG-ENV1 WWW.COMAIRCO.COM

    Automated ventilation

    One-piece steel floor

    Arched roof prevents water accumulation

    Thermal insulation and soundproofingprotect against extreme weather conditions

    AWA - 50 TWIN AWA - 50 AWA-50 TDF

    EVERY PROJECT IS UNIQUE. THAT’S WHY OUR AWA’S ARE FULLY CUSTOMIZABLE.

    HERE ARE SOME OPTIONS AVAILABLE.

    • All makes and models of compressors can be installed in our AWA including Class 0 Oil-Free Models ISO 8573-1.

    • Heat recovery for external use.

    • Outdoor lighting with photo-voltaic cells.

    • Fire extinguishers, ANSUL system.

    • Stainless steel ventilation louvers.

    • Structural modification for lifting by crane.

    • Remote control and monitoring CCRM. *• Custom paint jobs according to your specifications.

    • Multi-voltage electrical panels.

    • Sound or visual alarm equipment.

    • Non-standard widths.

    * available on certain models

    Lockable doors withsecure windows

    MODEL MAX. FLOW (cfm) LENGTH * WIDTH HEIGHT WEIGHT (lb) ** CONNECTION

    AWA - 25 140 78” 64” 114” 2200 1 ½” NPT

    AWA - 25/TDF 140 102” 102” 114” 3470 1 ½” NPT

    AWA – 50 270 84” 102” 114” 3670 1 ½” NPT

    AWA - 50/TDF 270 108” 102” 114” 4480 1 ½” NPT

    AWA – 100 500 114” 102” 116” 4690 2”

    AWA - 100/TDF 500 180’’ 102” 116” 6,530 2”

    AWA – 200 1050 144” 102” 120” 5,040 2”

    AWA - 200/TDF 1050 216” 102” 120” 7,270 2”

    AWA – 300 1875 192” 102” 128” 6,700 3”

    AWA - 400 2350 216” 102” 132” 9,720 4” FLG

    AWA-TURBO 6000 Custom

    AWA-CUSTOM Contact us

    *subject to change ** without equipment

    DIMENSIONS TABLESizes, weights and specifications of standard models (others models also available).

    Add 24’’ for stepladders.** Dimensions and weights can change based on the equipment selected.

    AWA – 300 AWA – 300 AWA – 50

    ARE YOU THINKING ABOUT EXPANDING YOUR CURRENT BUILDING...AN AWA COULD BE A MUCH MORE ECONONOMICAL OPTION.By expanding your facilities, have you thought about...

    Time required for:• the steps to be taken in the urban planning office• building permit to be approved?• the new certificate of location?• the selection of the contractor?• check the progress of the work?• manage the unanticipated?

    Fees:• related to construction?• the unexpected? (Project Delays)• to extras? (Cost Over-Runs)• municipal taxes that will increase as your area increases?• architects’ fees• from an accounting point of view, the extra floor space not used for production also reduces the square foot efficiency of your plant?

    Eliminate the headache of planning and managing a plant expansion. The selection of an AWA mobile unit by Comairco saves you time, money & manufacturing floor space. It couldn’t be simpler!

  • Comairco, a leader in North America with more than 20 branches in Canada and the United States, and over 40 years in the compressed air industry, presents AWA, (All Weather Air), portable stations. These units combine durability, reliability and ease of use to operate your compressed air equipment outdoors year-round, regardless of the weather conditions.

    Distributed in more than 10 countries AWA are used for permanent and short-term installations (rentals), when there is a lack of interior space, or to reduce the cost of installation, to protect your equipment against the weather, or simply to reduce noise levels (DBA) in the facility. The AWA offers a reduced operating cost of up to eight times less than an equivalent diesel compressor. AWA Unit Sea Container

    Wall Construction12 Gauge Steel cut and folded to give extreme rigidity to different AWA cabinet configurations.Allows the interior installation of various accessories.

    Corrugated steel panels; the installation of equipment and accessories inside is more complex and expensive.

    Floor structure One-piece steel floor ¼ thick. Facilitates the securing of equipment, directly to the floor.

    Wood floor does not contain fluid flows. Difficult to achieve adequate securing of equipment.

    Access / DoorsOne of the great strengths of AWA, between 3 and 8 * large doors strategically placed to easily maintain any equipment inside. (* Depending on the size of the AWA).

    Often only 1 door available. The adding of extra doors is often expensive and often not hermetic.

    Roof Inclined to prevent water accumulation. Some equipment can be easily attached to the ceiling using roof trusses.

    Flat, contributes to water accumulation and possibility of water infiltration. Adding equipment to the ceiling is more complex; requires more hardware and installation time.

    VentilationLarge dedicated wall openings suitable for all types of compressors. No need to roof mount air deflectors, no additional handling on site allows for easy transportation.

    Wall ventilation difficult, additional equipment (deflectors) on the roof are often necessary and add expense. Roof penetration usually necessary which can lead to water infiltration. Additional handling on-site often required.

    Soundproofing and insulation

    1” of industrial urethane foam insulation. Absorbs compressor noise and prevents condensation. Also available in sprayed urethane. Protects equipment in environments from -40°F to +120°F.

    Insulation and soundproofing optional. Often costly in installation labor.

    Transportation to the site Numerous anchor points for easy truck transportation. Same as a regular container.

    Mobility

    Rugged draggable skid with large eyelets allowing for move-ment on site. Forklift pockets in the base for handling by forklift.Optional: reinforced certified crane structure with 4 attachment points.

    Opening in the base for handling by forklift only.

    Width Option to make custom widths to suit equipment requirement. Standard width 96“.

    PaintSurface preparation with sandblasting. Standard: 2-Component Urethane DTM. Option to use any other existing system as required.

    Paint system from the container manufacturer. Painting system difficult to establish. Rusts easily.

    AestheticsModern industrial design with clean lines, the AWA can be seen without disturbing the landscape. Our choices of colors allow you to completely match the color of your existing installations.

    Cube without aesthetics. Does not blend well in most environments, difficult to match existing structures.

    Country of origin Made entirely in North America. Typically made in China.

    COMPARATIVE BOARD BETWEEN AWA UNIT AND SEA STANDARD CONTAINER

    When deciding to put compressed air equipment outdoors, many solutions are often evaluated, the sea container is frequently compared to the AWA. Here is a comparison chart that illustrates the main differences.

    STANDARD OPTIONAL

    Roof Cambered roof with integrated gutters assures no water infiltration or accumulation.

    Doors Lockable door. Solid or windowed doors.

    Ventilation Panels Automatic louvers, insulated made of aluminum. Automatic louvers made of stainless steel available.Gooseneck entry and high efficiency filter protection standard.

    Floor One-piece, liquid resistant, steel floor provides full containment thus preventing soil contamination.Paint Color Charcoal Standard. Customer colors available.

    Paint system 2-component urethane paint system standard. Alternate systems for all types of environments.

    Outdoor lighting - Photovoltaic lighting.

    EXTERIOR

    Ventilation Thermostatically Controlled Ventilation. Heat recovery for redistribution in your building available.

    Electrical connection - Electrical quick connection for power supply optional available on some models, (consult Factory).

    Piping Aluminum system standard. Choice of piping available.

    Indoor heating Convection auxiliary heating, internal heat recovery.

    Electrical panel and electricity

    NEMA 4 CSA Certification Standard, UL Listing, CSA-US, with integrated circuit breakers standard.

    NEMA 4X. With additional breakers available.

    Filters Filtration on the air inlet standard. Selection of filters according to your site conditions available.

    Indoor lighting Tubes standard. Industrial protected fluorescent.

    Isolation Industrial Sprayed urethane thermal insulation with 1”. Foam standard.

    INTERIOR

    Remote monitoring -

    Remote Monitoring via CCRM System. Multiple screen formats. Accessible online. Pressure reading and temperature alarms. Events recording in an exportable file. Available on AWA-25, 50 and 100.

    Unit Moving By forklift. 4 lashing hooks for transport standard.

    Optional crane structure for lifting.

    Operation indicator lights and security

    -Selection of warning beacons and sirens. Fire extinguisher, ANSUL system.

    Certification CSA Certification standard. Other certifications available on demand.

    Onsite Equipmentmaintenance

    Equipment maintenance plan offered by Comairco certified technicians.

    ADDITIONAL EQUIPMENT AVAILABLE

    We can design and manufacture custom installations that will suit your needs.Moving by forklift

    Moving by crane

    Inside view

    AWA - 200

    AWA - CUSTOM

    WHY CHOOSE AN AWA?

    Equipment

    • To decrease the noise levels inside; the insulation of walls and doors considerably reduces noise levels around exterior of package.

    • Free up valuable manufacturing space for more production equipment.

    • Flexible solution; temporary or permanent solution.

    • Tested in environment from - 40°F to + 120°F.

    • Electric compressor vs Diesel compressor is approximately 8 times more energy efficient.

    • Being a mobile container your local municipality may not increase your taxes since this is not considered a permanent structure improvement. Check with your tax advisor.

    • Maximizes the efficiency of your electric air compressor outside.

    • Ease of maintenance due to multiple doors providing easy access to the equipment inside.

    • Designed to be easily transported and moved.

    • The rugged enclosure protects your equipment from the worst weather conditions.

    • Automated controls provide the proper internal container temperatures all year round.

    • No concrete slab or additional installation required.*

    • Only one electrical and pneumatic connection required.

    • Possibility to put your existing equipment inside an AWA.

    • Can accommodate nitrogen generators.

    *(except model AWA400 and larger)

  • Comairco, a leader in North America with more than 20 branches in Canada and the United States, and over 40 years in the compressed air industry, presents AWA, (All Weather Air), portable stations. These units combine durability, reliability and ease of use to operate your compressed air equipment outdoors year-round, regardless of the weather conditions.

    Distributed in more than 10 countries AWA are used for permanent and short-term installations (rentals), when there is a lack of interior space, or to reduce the cost of installation, to protect your equipment against the weather, or simply to reduce noise levels (DBA) in the facility. The AWA offers a reduced operating cost of up to eight times less than an equivalent diesel compressor. AWA Unit Sea Container

    Wall Construction12 Gauge Steel cut and folded to give extreme rigidity to different AWA cabinet configurations.Allows the interior installation of various accessories.

    Corrugated steel panels; the installation of equipment and accessories inside is more complex and expensive.

    Floor structure One-piece steel floor ¼ thick. Facilitates the securing of equipment, directly to the floor.

    Wood floor does not contain fluid flows. Difficult to achieve adequate securing of equipment.

    Access / DoorsOne of the great strengths of AWA, between 3 and 8 * large doors strategically placed to easily maintain any equipment inside. (* Depending on the size of the AWA).

    Often only 1 door available. The adding of extra doors is often expensive and often not hermetic.

    Roof Inclined to prevent water accumulation. Some equipment can be easily attached to the ceiling using roof trusses.

    Flat, contributes to water accumulation and possibility of water infiltration. Adding equipment to the ceiling is more complex; requires more hardware and installation time.

    VentilationLarge dedicated wall openings suitable for all types of compressors. No need to roof mount air deflectors, no additional handling on site allows for easy transportation.

    Wall ventilation difficult, additional equipment (deflectors) on the roof are often necessary and add expense. Roof penetration usually necessary which can lead to water infiltration. Additional handling on-site often required.

    Soundproofing and insulation

    1” of industrial urethane foam insulation. Absorbs compressor noise and prevents condensation. Also available in sprayed urethane. Protects equipment in environments from -40°F to +120°F.

    Insulation and soundproofing optional. Often costly in installation labor.

    Transportation to the site Numerous anchor points for easy truck transportation. Same as a regular container.

    Mobility

    Rugged draggable skid with large eyelets allowing for move-ment on site. Forklift pockets in the base for handling by forklift.Optional: reinforced certified crane structure with 4 attachment points.

    Opening in the base for handling by forklift only.

    Width Option to make custom widths to suit equipment requirement. Standard width 96“.

    PaintSurface preparation with sandblasting. Standard: 2-Component Urethane DTM. Option to use any other existing system as required.

    Paint system from the container manufacturer. Painting system difficult to establish. Rusts easily.

    AestheticsModern industrial design with clean lines, the AWA can be seen without disturbing the landscape. Our choices of colors allow you to completely match the color of your existing installations.

    Cube without aesthetics. Does not blend well in most environments, difficult to match existing structures.

    Country of origin Made entirely in North America. Typically made in China.

    COMPARATIVE BOARD BETWEEN AWA UNIT AND SEA STANDARD CONTAINER

    When deciding to put compressed air equipment outdoors, many solutions are often evaluated, the sea container is frequently compared to the AWA. Here is a comparison chart that illustrates the main differences.

    STANDARD OPTIONAL

    Roof Cambered roof with integrated gutters assures no water infiltration or accumulation.

    Doors Lockable door. Solid or windowed doors.

    Ventilation Panels Automatic louvers, insulated made of aluminum. Automatic louvers made of stainless steel available.Gooseneck entry and high efficiency filter protection standard.

    Floor One-piece, liquid resistant, steel floor provides full containment thus preventing soil contamination.Paint Color Charcoal Standard. Customer colors available.

    Paint system 2-component urethane paint system standard. Alternate systems for all types of environments.

    Outdoor lighting - Photovoltaic lighting.

    EXTERIOR

    Ventilation Thermostatically Controlled Ventilation. Heat recovery for redistribution in your building available.

    Electrical connection - Electrical quick connection for power supply optional available on some models, (consult Factory).

    Piping Aluminum system standard. Choice of piping available.

    Indoor heating Convection auxiliary heating, internal heat recovery.

    Electrical panel and electricity

    NEMA 4 CSA Certification Standard, UL Listing, CSA-US, with integrated circuit breakers standard.

    NEMA 4X. With additional breakers available.

    Filters Filtration on the air inlet standard. Selection of filters according to your site conditions available.

    Indoor lighting Tubes standard. Industrial protected fluorescent.

    Isolation Industrial Sprayed urethane thermal insulation with 1”. Foam standard.

    INTERIOR

    Remote monitoring -

    Remote Monitoring via CCRM System. Multiple screen formats. Accessible online. Pressure reading and temperature alarms. Events recording in an exportable file. Available on AWA-25, 50 and 100.

    Unit Moving By forklift. 4 lashing hooks for transport standard.

    Optional crane structure for lifting.

    Operation indicator lights and security

    -Selection of warning beacons and sirens. Fire extinguisher, ANSUL system.

    Certification CSA Certification standard. Other certifications available on demand.

    Onsite Equipmentmaintenance

    Equipment maintenance plan offered by Comairco certified technicians.

    ADDITIONAL EQUIPMENT AVAILABLE

    We can design and manufacture custom installations that will suit your needs.Moving by forklift

    Moving by crane

    Inside view

    AWA - 200

    AWA - CUSTOM

    WHY CHOOSE AN AWA?

    Equipment

    • To decrease the noise levels inside; the insulation of walls and doors considerably reduces noise levels around exterior of package.

    • Free up valuable manufacturing space for more production equipment.

    • Flexible solution; temporary or permanent solution.

    • Tested in environment from - 40°F to + 120°F.

    • Electric compressor vs Diesel compressor is approximately 8 times more energy efficient.

    • Being a mobile container your local municipality may not increase your taxes since this is not considered a permanent structure improvement. Check with your tax advisor.

    • Maximizes the efficiency of your electric air compressor outside.

    • Ease of maintenance due to multiple doors providing easy access to the equipment inside.

    • Designed to be easily transported and moved.

    • The rugged enclosure protects your equipment from the worst weather conditions.

    • Automated controls provide the proper internal container temperatures all year round.

    • No concrete slab or additional installation required.*

    • Only one electrical and pneumatic connection required.

    • Possibility to put your existing equipment inside an AWA.

    • Can accommodate nitrogen generators.

    *(except model AWA400 and larger)

  • Comairco, a leader in North America with more than 20 branches in Canada and the United States, and over 40 years in the compressed air industry, presents AWA, (All Weather Air), portable stations. These units combine durability, reliability and ease of use to operate your compressed air equipment outdoors year-round, regardless of the weather conditions.

    Distributed in more than 10 countries AWA are used for permanent and short-term installations (rentals), when there is a lack of interior space, or to reduce the cost of installation, to protect your equipment against the weather, or simply to reduce noise levels (DBA) in the facility. The AWA offers a reduced operating cost of up to eight times less than an equivalent diesel compressor. AWA Unit Sea Container

    Wall Construction12 Gauge Steel cut and folded to give extreme rigidity to different AWA cabinet configurations.Allows the interior installation of various accessories.

    Corrugated steel panels; the installation of equipment and accessories inside is more complex and expensive.

    Floor structure One-piece steel floor ¼ thick. Facilitates the securing of equipment, directly to the floor.

    Wood floor does not contain fluid flows. Difficult to achieve adequate securing of equipment.

    Access / DoorsOne of the great strengths of AWA, between 3 and 8 * large doors strategically placed to easily maintain any equipment inside. (* Depending on the size of the AWA).

    Often only 1 door available. The adding of extra doors is often expensive and often not hermetic.

    Roof Inclined to prevent water accumulation. Some equipment can be easily attached to the ceiling using roof trusses.

    Flat, contributes to water accumulation and possibility of water infiltration. Adding equipment to the ceiling is more complex; requires more hardware and installation time.

    VentilationLarge dedicated wall openings suitable for all types of compressors. No need to roof mount air deflectors, no additional handling on site allows for easy transportation.

    Wall ventilation difficult, additional equipment (deflectors) on the roof are often necessary and add expense. Roof penetration usually necessary which can lead to water infiltration. Additional handling on-site often required.

    Soundproofing and insulation

    1” of industrial urethane foam insulation. Absorbs compressor noise and prevents condensation. Also available in sprayed urethane. Protects equipment in environments from -40°F to +120°F.

    Insulation and soundproofing optional. Often costly in installation labor.

    Transportation to the site Numerous anchor points for easy truck transportation. Same as a regular container.

    Mobility

    Rugged draggable skid with large eyelets allowing for move-ment on site. Forklift pockets in the base for handling by forklift.Optional: reinforced certified crane structure with 4 attachment points.

    Opening in the base for handling by forklift only.

    Width Option to make custom widths to suit equipment requirement. Standard width 96“.

    PaintSurface preparation with sandblasting. Standard: 2-Component Urethane DTM. Option to use any other existing system as required.

    Paint system from the container manufacturer. Painting system difficult to establish. Rusts easily.

    AestheticsModern industrial design with clean lines, the AWA can be seen without disturbing the landscape. Our choices of colors allow you to completely match the color of your existing installations.

    Cube without aesthetics. Does not blend well in most environments, difficult to match existing structures.

    Country of origin Made entirely in North America. Typically made in China.

    COMPARATIVE BOARD BETWEEN AWA UNIT AND SEA STANDARD CONTAINER

    When deciding to put compressed air equipment outdoors, many solutions are often evaluated, the sea container is frequently compared to the AWA. Here is a comparison chart that illustrates the main differences.

    STANDARD OPTIONAL

    Roof Cambered roof with integrated gutters assures no water infiltration or accumulation.

    Doors Lockable door. Solid or windowed doors.

    Ventilation Panels Automatic louvers, insulated made of aluminum. Automatic louvers made of stainless steel available.Gooseneck entry and high efficiency filter protection standard.

    Floor One-piece, liquid resistant, steel floor provides full containment thus preventing soil contamination.Paint Color Charcoal Standard. Customer colors available.

    Paint system 2-component urethane paint system standard. Alternate systems for all types of environments.

    Outdoor lighting - Photovoltaic lighting.

    EXTERIOR

    Ventilation Thermostatically Controlled Ventilation. Heat recovery for redistribution in your building available.

    Electrical connection - Electrical quick connection for power supply optional available on some models, (consult Factory).

    Piping Aluminum system standard. Choice of piping available.

    Indoor heating Convection auxiliary heating, internal heat recovery.

    Electrical panel and electricity

    NEMA 4 CSA Certification Standard, UL Listing, CSA-US, with integrated circuit breakers standard.

    NEMA 4X. With additional breakers available.

    Filters Filtration on the air inlet standard. Selection of filters according to your site conditions available.

    Indoor lighting Tubes standard. Industrial protected fluorescent.

    Isolation Industrial Sprayed urethane thermal insulation with 1”. Foam standard.

    INTERIOR

    Remote monitoring -

    Remote Monitoring via CCRM System. Multiple screen formats. Accessible online. Pressure reading and temperature alarms. Events recording in an exportable file. Available on AWA-25, 50 and 100.

    Unit Moving By forklift. 4 lashing hooks for transport standard.

    Optional crane structure for lifting.

    Operation indicator lights and security

    -Selection of warning beacons and sirens. Fire extinguisher, ANSUL system.

    Certification CSA Certification standard. Other certifications available on demand.

    Onsite Equipmentmaintenance

    Equipment maintenance plan offered by Comairco certified technicians.

    ADDITIONAL EQUIPMENT AVAILABLE

    We can design and manufacture custom installations that will suit your needs.Moving by forklift

    Moving by crane

    Inside view

    AWA - 200

    AWA - CUSTOM

    WHY CHOOSE AN AWA?

    Equipment

    • To decrease the noise levels inside; the insulation of walls and doors considerably reduces noise levels around exterior of package.

    • Free up valuable manufacturing space for more production equipment.

    • Flexible solution; temporary or permanent solution.

    • Tested in environment from - 40°F to + 120°F.

    • Electric compressor vs Diesel compressor is approximately 8 times more energy efficient.

    • Being a mobile container your local municipality may not increase your taxes since this is not considered a permanent structure improvement. Check with your tax advisor.

    • Maximizes the efficiency of your electric air compressor outside.

    • Ease of maintenance due to multiple doors providing easy access to the equipment inside.

    • Designed to be easily transported and moved.

    • The rugged enclosure protects your equipment from the worst weather conditions.

    • Automated controls provide the proper internal container temperatures all year round.

    • No concrete slab or additional installation required.*

    • Only one electrical and pneumatic connection required.

    • Possibility to put your existing equipment inside an AWA.

    • Can accommodate nitrogen generators.

    *(except model AWA400 and larger)

  • ENGINEERED SERVICE SOLUTION

    MOBILECOMPRESSED AIR SYSTEM

    MARKCO-AWAG-ENV1 WWW.COMAIRCO.COM

    Automated ventilation

    One-piece steel floor

    Arched roof prevents water accumulation

    Thermal insulation and soundproofingprotect against extreme weather conditions

    AWA - 50 TWIN AWA - 50 AWA-50 TDF

    EVERY PROJECT IS UNIQUE. THAT’S WHY OUR AWA’S ARE FULLY CUSTOMIZABLE.

    HERE ARE SOME OPTIONS AVAILABLE.

    • All makes and models of compressors can be installed in our AWA including Class 0 Oil-Free Models ISO 8573-1.

    • Heat recovery for external use.

    • Outdoor lighting with photo-voltaic cells.

    • Fire extinguishers, ANSUL system.

    • Stainless steel ventilation louvers.

    • Structural modification for lifting by crane.

    • Remote control and monitoring CCRM. *• Custom paint jobs according to your specifications.

    • Multi-voltage electrical panels.

    • Sound or visual alarm equipment.

    • Non-standard widths.

    * available on certain models

    Lockable doors withsecure windows

    MODEL MAX. FLOW (cfm) LENGTH * WIDTH HEIGHT WEIGHT (lb) ** CONNECTION

    AWA - 25 140 78” 64” 114” 2200 1 ½” NPT

    AWA - 25/TDF 140 102” 102” 114” 3470 1 ½” NPT

    AWA – 50 270 84” 102” 114” 3670 1 ½” NPT

    AWA - 50/TDF 270 108” 102” 114” 4480 1 ½” NPT

    AWA – 100 500 114” 102” 116” 4690 2”

    AWA - 100/TDF 500 180’’ 102” 116” 6,530 2”

    AWA – 200 1050 144” 102” 120” 5,040 2”

    AWA - 200/TDF 1050 216” 102” 120” 7,270 2”

    AWA – 300 1875 192” 102” 128” 6,700 3”

    AWA - 400 2350 216” 102” 132” 9,720 4” FLG

    AWA-TURBO 6000 Custom

    AWA-CUSTOM Contact us

    *subject to change ** without equipment

    DIMENSIONS TABLESizes, weights and specifications of standard models (others models also available).

    Add 24’’ for stepladders.** Dimensions and weights can change based on the equipment selected.

    AWA – 300 AWA – 300 AWA – 50

    ARE YOU THINKING ABOUT EXPANDING YOUR CURRENT BUILDING...AN AWA COULD BE A MUCH MORE ECONONOMICAL OPTION.By expanding your facilities, have you thought about...

    Time required for:• the steps to be taken in the urban planning office• building permit to be approved?• the new certificate of location?• the selection of the contractor?• check the progress of the work?• manage the unanticipated?

    Fees:• related to construction?• the unexpected? (Project Delays)• to extras? (Cost Over-Runs)• municipal taxes that will increase as your area increases?• architects’ fees• from an accounting point of view, the extra floor space not used for production also reduces the square foot efficiency of your plant?

    Eliminate the headache of planning and managing a plant expansion. The selection of an AWA mobile unit by Comairco saves you time, money & manufacturing floor space. It couldn’t be simpler!

  • ENGINEERED SERVICE SOLUTION

    MOBILECOMPRESSED AIR SYSTEM

    MARKCO-AWAG-ENV1 WWW.COMAIRCO.COM

    Automated ventilation

    One-piece steel floor

    Arched roof prevents water accumulation

    Thermal insulation and soundproofingprotect against extreme weather conditions

    AWA - 50 TWIN AWA - 50 AWA-50 TDF

    EVERY PROJECT IS UNIQUE. THAT’S WHY OUR AWA’S ARE FULLY CUSTOMIZABLE.

    HERE ARE SOME OPTIONS AVAILABLE.

    • All makes and models of compressors can be installed in our AWA including Class 0 Oil-Free Models ISO 8573-1.

    • Heat recovery for external use.

    • Outdoor lighting with photo-voltaic cells.

    • Fire extinguishers, ANSUL system.

    • Stainless steel ventilation louvers.

    • Structural modification for lifting by crane.

    • Remote control and monitoring CCRM. *• Custom paint jobs according to your specifications.

    • Multi-voltage electrical panels.

    • Sound or visual alarm equipment.

    • Non-standard widths.

    * available on certain models

    Lockable doors withsecure windows

    MODEL MAX. FLOW (cfm) LENGTH * WIDTH HEIGHT WEIGHT (lb) ** CONNECTION

    AWA - 25 140 78” 64” 114” 2200 1 ½” NPT

    AWA - 25/TDF 140 102” 102” 114” 3470 1 ½” NPT

    AWA – 50 270 84” 102” 114” 3670 1 ½” NPT

    AWA - 50/TDF 270 108” 102” 114” 4480 1 ½” NPT

    AWA – 100 500 114” 102” 116” 4690 2”

    AWA - 100/TDF 500 180’’ 102” 116” 6,530 2”

    AWA – 200 1050 144” 102” 120” 5,040 2”

    AWA - 200/TDF 1050 216” 102” 120” 7,270 2”

    AWA – 300 1875 192” 102” 128” 6,700 3”

    AWA - 400 2350 216” 102” 132” 9,720 4” FLG

    AWA-TURBO 6000 Custom

    AWA-CUSTOM Contact us

    *subject to change ** without equipment

    DIMENSIONS TABLESizes, weights and specifications of standard models (others models also available).

    Add 24’’ for stepladders.** Dimensions and weights can change based on the equipment selected.

    AWA – 300 AWA – 300 AWA – 50

    ARE YOU THINKING ABOUT EXPANDING YOUR CURRENT BUILDING...AN AWA COULD BE A MUCH MORE ECONONOMICAL OPTION.By expanding your facilities, have you thought about...

    Time required for:• the steps to be taken in the urban planning office• building permit to be approved?• the new certificate of location?• the selection of the contractor?• check the progress of the work?• manage the unanticipated?

    Fees:• related to construction?• the unexpected? (Project Delays)• to extras? (Cost Over-Runs)• municipal taxes that will increase as your area increases?• architects’ fees• from an accounting point of view, the extra floor space not used for production also reduces the square foot efficiency of your plant?

    Eliminate the headache of planning and managing a plant expansion. The selection of an AWA mobile unit by Comairco saves you time, money & manufacturing floor space. It couldn’t be simpler!