Fluorescent Response of Blue/ Green Proteins to Thermal

CyclingAvantes Demonstration for SPIE Photonics West/ BiOS 2017 utilizing the new Avaspec-HERO spectrometer

Page 3: Avantes measurements with fluorescent proteins

History of Green Fluorescent Protein

The first green fluorescing proteins were discovered in 1955 when isolated from the DNA of jellyfish.

This discovery allowed researchers to study the structures and processes of living cells on a molecular level like never before using optical microscopy.

Page 4: Avantes measurements with fluorescent proteins

The Use of Green Fluorescent Protein

Initial use of fluorescing proteins was limited only by the technology to read such minute signals. Advances in Lasers, Fiber Optics and Computers in the 1990’s opened the door for advancing medical research using fluorescence spectrometry.

Page 5: Avantes measurements with fluorescent proteins

Fluorescent Proteins in Today’s WorldToday, researchers in the lab, medical professionals in practice, and many industry professionals use a variety of fluorescing proteins (FPs). Applications for fluorescence include chemical sensors, fluorescent labeling, biological detectors, fluorescent lighting, dyes, mineralogy and more.

Page 6: Avantes measurements with fluorescent proteins

Measuring Fluorescence

Fluorescence takes place when a substance is exposed to radiation of a short wavelength and emits light at a longer wavelength, usually in the visible spectrum.

Fluorescence spectroscopy, or fluorometry, is the measurement of fluorescence using an ultraviolet or other light source to excite the electrons in a sample. The resulting output is measured at a 90° angle from excitation beam.

Page 7: Avantes measurements with fluorescent proteins

The Challenge of FluorescenceMeasuring Fluorescence has always posed a challenge for researchers, scientists and engineers. Stray light from the sample, low-light sampling, and even temperature variations can be a source of noise making it difficult to isolate the signal...until now!

Page 8: Avantes measurements with fluorescent proteins

Introducing the AvaSpec-HERO

For testing conditions that require the highest resolution AND the highest sensitivity, such as fluorescence, the AvaSpec-HERO saves the day.The AvaSpec-HERO Combines the:

● Avantes High Sensitivity Compact 100mm optical bench offering a NA of 0.13 and a cooled Backthinned Detector (1024x58 pixels) &

● Newest AS7010 electrical board with high performance analog to digital convertorThe AvaSpec-HERO delivers unparalleled noise

performance.

Page 9: Avantes measurements with fluorescent proteins

Fluorescent Response to Thermal Cycling DemoEquipment used at the U.S. engineering facilities for

testing:● AvaSpec-HERO● AvaLight-LED light source● Quantum Northwest qpod 2e samples of BFP (Blue

Fluorescent Proteins) and GFP (Green Fluorescent Proteins)

● Pump, tubing, and hot/cold water for thermal cycling regulation

Page 10: Avantes measurements with fluorescent proteins

Fluorescent Response to Thermal Cycling

BFP and GFP samples were stimulated using an excitation wavelength of 370nm while thermally cycling the samples between 15°C and 55°C.The BFP and GFP samples emitted fluorescent light at 452nm and 510nm respectively.

Page 11: Avantes measurements with fluorescent proteins

BFP Excitation and Response at 55°C

Excitation Wavelength: 370 nm

Fluorescence Emission: 452 nm

The AvaSpec-HERO delivers consistently superior data results

Page 12: Avantes measurements with fluorescent proteins

GFP Excitation and Response at 55°C Excitation Wavelength: 370 nm

Fluorescence Emission: 510 nm

Again, the AvaSpec-HERO delivers the clearest, lowest noise to signal results on the market

Page 13: Avantes measurements with fluorescent proteins

Effects of Thermal Cycling on BFG FluorescenceThermal cycling, intended to

mimic possible test conditions in the field, demonstrates the stability of the HERO’s measurement capability over a long test cycle.It is possible to observe the inverse relationship of temperature on fluorescent light emission clearly over multiple cycles.

Page 14: Avantes measurements with fluorescent proteins

Effects of Thermal Cycling on GFG Fluorescence Again, the HERO delivers

superior data results with ultra-low noise and accuracy over the test duration.Future developments from AvaSoft in straylight control and process customization paired with the HERO system will provide exceptional results in even the most demanding clinical setting.

Page 15: Avantes measurements with fluorescent proteins

Learn More About Avantes ProductsSpeak to a local Sales Engineer or distributor about system requirements for your specific application today, or visit our website for application notes and information

Find a DistributorVisit the Avantes website at:

http://www.avantes.com/company/distributors

Page 16: Avantes measurements with fluorescent proteins

Avantes for OEM solutionsAvantes’ leading edge technologies and years of manufacturing expertise make us the ideal OEM partner for your fluorescence measurement solution.

Discover our OEM Expertise