AutoCAD Standards Guide Version 2004 January 2004

Prepared by: Engineering Standards Branch, Highways and Business Servicess Applications Solution Branch, Ministry of Transportation Contact: Application Resource Desk (905) 704-2423

Page 2: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

AutoCAD Standards Guide Version 2004 January 2004

Prepared by: Engineering Standards Branch, ISBN 0-7794-6739-6 Highways and Business Services Applications Solution Branch © 2004, Queen's Printer for Ontario

Contact: Application Resource Desk Reproduced with permission. (905)704-2423

Page 3: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

To all users of this publication: The information contained herein has been carefully compiled and is believed to be accurate at the date of publication. Freedom from error, however, cannot be guaranteed. Enquires regarding the purchase and distribution of this manual should be directed to: Publications Ontario By telephone: 1-800-668-9938 By fax: (613) 566-2234 TTY: 1-800-268-7095 Online: www.publications.gov.on.ca Enquires regarding amendments, suggestions, or comments should be directed to the Ministry of Transportation at (905) 704-2065.

Page 4: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

REVISION SUMMARY

Document Revision

Date Summary of Changes

1.0 Feb. 1997 1.1 Nov. 1997 - Revised OPSD Layer Standards 2.0 Dec. 1998 - Updated AutoCAD Text Style Standard

- Additional Custom MTO LineTypes - Updated AutoCAD Colour Assignments for Plot Pen Mapping - Removed AutoCAD Menu Customization Standards - Revised Electrical Design Drawing Standards - Revised Photogrammetry Drawing Standards - Revised Planning & Design Drawing Standards - Revised Surveys & Plans Drawing Standards - Revised Traffic Drawing Standards - IESCAD Customization Modules available for: Photogrammetry Planning & Design Surveys & Plans

- Digital prototype drawings and symbols available for: Electrical Design

2.1 May 2000 - IESCAD Customization Modules available for: Electrical Traffic OPSD Structural

3.0 Jan. 2001 - No changes 3.0.1 Oct. 2002 - No changes 2004 Jan. 2004 - Revised OPSD Layer Standards

- Added Geotechnical and Foundations layer standards

Page 5: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

CONTACTS FOR AUTOCAD LAYERING CONVENTION STANDARDS

BUSINESS FUNCTION

CONTACT PERSON

OFFICE LOCATION

PHONE NUMBER

Surveys and Plans

Ron Berg

St. Catharines 2nd Floor

(905) 704-2330

Planning and Design

Hanna Hanna

St. Catharines 2nd Floor

(905) 704-2272

Structural Design

Tony Merlo

St. Catharines 2nd Floor

(905) 704-2384

Electrical Engineering

Elizabeth Bojanowska

St. Catharines 2nd Floor

(905) 704-2219

Advanced Traffic Management

Gilbert May

Downsview Atrium Tower, 6th Floor

(416) 235-5606

Geotechnical

Stan Morris

Eastern Region, Geotechnical

(613) 544-2220

Photogrammetry

Ron Berg

St. Catharines 2nd Floor

(905) 704-2330

Drainage and Hydrology

Art Groenveld

St. Catharines 2nd Floor

(905) 704-2239

Foundation Design

David Dundas

Downsview, 3rd Floor, Central Building

(416) 235-3731

Traffic

Mazda Hodiwala

St. Catharines 2nd Floor

(905) 704-2954

Environmental

Nick Close

St. Catharines Mezzanine Level

(905) 704-2229

Ontario Provincial Standards

Victor Weziak

St. Catharines 2nd Floor

(905) 704-2280

Page 6: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

TABLE OF CONTENTS

1.0 INTRODUCTION........................................................................................................................................................1

2.0 CAD LAYER NAMING..............................................................................................................................................2

2.1 FEATURE-ORIENTED LAYER NAMING CONVENTION ................................................................................................... 3 2.2 DRAFTING-ORIENTED LAYER NAMING CONVENTION .................................................................................................. 5

3.0 AUTOCAD TEXT STYLE STANDARD.....................................................................................................................7

3.1 CUSTOM AUTOCAD TEXT FONT ................................................................................................................................. 8

4.0 CUSTOM MTO LINE TYPES...................................................................................................................................9

4.1 DEFINITIONS OF CUSTOM MTO LINE TYPES......................................................................................................... 10

5.0 STANDARD PLOT ASSIGNMENTS.......................................................................................................................12

5.1 AUTOCAD COLOUR ASSIGNMENTS............................................................................................................................ 13 5.2 LEROY EQUIVALENT .................................................................................................................................................. 14

6.0 STANDARD AUTOCAD SYMBOLS ......................................................................................................................15

APPENDIX A: LAYER STANDARDS ..........................................................................................................................16

APPENDIX A-1 - ADVANCED TRAFFIC DRAWINGS APPENDIX A-2 - ELECTRICAL DESIGN DRAWINGS APPENDIX A-3 - ENVIRONMENTAL DRAWINGS APPENDIX A-4 - FOUNDATION DRAWINGS APPENDIX A-5 - GEOTECHNICAL DRAWINGS APPENDIX A-6 - ONTARIO PROVINCIAL STANDARD DRAWINGS APPENDIX A-7 - PLANNING & DESIGN DRAWINGS APPENDIX A-8 - PHOTOGRAMMETRY DRAWINGS APPENDIX A-9 - SURVEYS & PLANS DRAWINGS APPENDIX A-10 - STRUCTURAL DRAWINGS APPENDIX A-11 - TRAFFIC DRAWINGS APPENDIX A-12 - GOTECHNICAL DRAWINGS APPENDIX A-13 - FOUNDATIONS DRAWINGS

Page 7: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

1

1.0 INTRODUCTION One of the major objectives of the Ontario Ministry of Transportation’s Integrated Engineering System (IES) project is to establish standards across engineering disciplines from Surveys to Construction. As the fundamental element of integration, everyone involved must consistently apply standards. The application of standards is therefore critical to the success of IES and ultimately to the success of the pre-contract engineering process. This document specifically targets standards as applied to Computer Aided Drafting (CAD) conventions to be applied during the preparation and delivery of engineering drawings. The mandate - to be formalized as a directive - is that all CAD produced MTO capital contract drawings must adhere to the standards outlined in this document. This document has been created to establish standards for application of AutoCAD as the common CADD tool for the creation of Pre-Contract Engineering drawings. Standards are included in this document for the following areas: * Drawings

- Layer Names & definitions - Text Fonts - Line Styles - Symbols

* Plot Configurations All functional areas in the Ministry responsible for producing Contract Drawings have agreed to the following standards and conventions.

Page 8: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

2

2.0 CAD LAYER NAMING Due to the different requirements, purpose, and level of detail of engineering drawings, two layer naming approaches have been established as standards: A. Feature Oriented:

Χ Layer names identify specific objects (linework, symbols) associated with the highway construction process (e.g. catch basin, traffic signal box).

Χ Layer names permit identification and manipulation of objects by name for viewing, plotting, querying, determining unit, linear and area quantities.

Χ All drafting information such as text, dimensions, hatch patterns are identified as entities associated to features, on separate layers.

B. Drafting Oriented:

Χ Layer names identify how objects are to be viewed (colour, linestyle) and plotted. Χ Acceptable for drawings, which do not contain features, that would be individually queried or manipulated.

Both feature and drafting oriented drawings often originate in one section and enter a work flow cycle to other offices for addition of function-specific features. Although two different layer naming approaches are established as standards, an attempt has been made to maintain the underlying conventions throughout.

Page 9: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

3

2.1 Feature-Oriented Layer Naming Convention The feature-oriented approach applies to the following type of drawings:

- Plan - Profile - Removals - Detail

The following are guidelines used to develop the Layer Naming approach for preparation of these types of Ministry contract drawings:

1. The Layer Name will: i. Be "feature-oriented" ii. Be hierarchical in nature iii. Consist of several components, delineated by dashes

2. The first component is a mandatory code that will identify the originating office or engineering discipline. 3. The second component is a mandatory code that will indicate the status (New, Existing, Removal, and

Future) of the features on that layer. 4. The Feature Code component of the layer name is the responsibility of each office, and can be as specific or

general as the office wishes. Features may be grouped or specified individually. 5. The last component of the layer name will be an optional definition of non-feature oriented data (i.e. text,

dimensions, patterns), which could be placed on a separate layer. The Layer Naming convention described above is as follows:

AA-B-C-C-C-C-C-D Maximum of 31 characters for entire layer name, including dashes. AA - An abbreviated code identifying the engineering discipline with "custodianship" of the layer:

i.e.: AT - Advanced Traffic DH - Drainage & Hydrology FD - Foundation GE - Geotechnical EL - Electrical EN - Environmental OPS - Ontario Provincial Standards (see Section 2.2) PD - Planning & Design PH - Photogrammetry SP - Surveys & Plans ST - Structural TR - Traffic

Page 10: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

4

B - Single character code identifying the "status" of the drawing feature. (See guideline 3)

i.e. E - Existing F - Future Feature N - New Construction R - Removals A - As Constructed

C-C-C-C-C - Feature specification of between 1-5 individual identifiers, hierarchically describing a drawing

feature in progressive detail.

i.e. RDS-EP - Roadway, Edge of Pavement DRN-CB - Drainage, Catch Basin

D - Optional single character code identifying the group name of graphical entities associated to a feature.

i.e. D - Dimensions P - Patterns (Hatching) T - Text (Annotation)

Examples: SP-E-VEG-WO Surveys & Plans layer, existing, vegetation, woods. PD-N-DRN-CB Planning & Design layer, new, drainage, catch basin. PD-N-DRN-CV-T Planning & Design layer, new, drainage, culvert, text.

Page 11: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

5

2.2 Drafting-Oriented Layer Naming Convention The layer naming approach used for Ontario Provincial Standards drawings (OPSDs), Typical Sections, and any drawing entities that are not feature specific will adhere to the "Drafting Oriented" convention. This approach identifies layers by how objects are to be viewed (colour, linestyle) and plotted.

The following are guidelines used to develop the Layer Naming approach for preparation of these types of Ministry contract drawings:

1. The Layer Name will: i. Identify the drafting entity ii. Consist of several components, delineated by dashes

2. The first component is a mandatory code that will identify the originating office or engineering discipline. 3. The second component is a mandatory code that will indicate the “General” status of the drawing entities on that

layer. 4. The remaining component of the layer name is used to specify the drafting entity type.

The Layer Naming convention described above is as follows:

AA-B-C-C Maximum of 31 characters for entire layer name, including dashes.

AA - An abbreviated code identifying the engineering discipline with "custodianship" of the layer:

i.e.: AT - Advanced Traffic DH - Drainage & Hydrology FD - Foundation GE - Geotechnical EL - Electrical EN - Environmental OPS - Ontario Provincial Standards (see Section 2.2) PD - Planning & Design PH - Photogrammetry SP - Surveys & Plans ST - Structural TR - Traffic

B - Single character code identifying the "status" of the drawing feature.

i.e. G - General S - Standard Drawing T - Typical Section

Page 12: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

6

C - Entity specification describing the type of entities to be placed on this layer or the pen thickness assigned.

i.e. TEXT - text entities SYMBOLS - symbols or block entities

25MM - 2.5mm plot pen 30MM - 3.0mm plot pen 40MM - 4.0mm plot pen 50MM - 5.0mm plot pen 60MM - 6.0mm plot pen

Examples:

SP-G-25MM Surveys & Plans layer, general (non-feature specific), 2.5mm lines.

PD-T-40MM Planning & Design layer, typical section, 4.0mm lines

PD-G-TEXT Planning & Design layer, general (non-feature specific), text.

Page 13: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

7

3.0 AutoCAD TEXT STYLE STANDARD The following table contains the standard for AutoCAD text styles.

Text Style Name Leroy

Equivalent Text Height Plot Pen

Thickness AutoCAD

Colour TEXT15 060 1.50mm 0.20mm 1 TEXT20 080 2.00mm 0.25mm 2 TEXT25 100 2.50mm 0.30mm 7 TEXT30 120 3.00mm 0.40mm 3 TEXT35 140 3.50mm 0.40mm 3 TEXT45 175 4.50mm 0.50mm 4 TEXT50 200 5.00mm 0.60mm 5 TEXT60 240 6.00mm 0.60mm 5 TEXT75 290 7.50mm 0.75mm 6 TEXT90 350 9.00mm 1.00mm 10

TEXT100 425 10.00mm 1.00mm 10 TEXT125 500 12.50mm 1.25mm 11 TEXT150 600 15.00mm 1.50mm 12 TEXT200 20.00mm 1.50mm 12

TEXT15B 060 1.50mm 0.20mm 1 TEXT20B 080 2.00mm 0.25mm 2 TEXT25B 100 2.50mm 0.30mm 7 TEXT30B 120 3.00mm 0.40mm 3 TEXT35B 140 3.50mm 0.40mm 3 TEXT45B 175 4.50mm 0.50mm 4 TEXT50B 200 5.00mm 0.60mm 5 TEXT60B 240 6.00mm 0.60mm 5 TEXT75B 290 7.50mm 0.75mm 6 TEXT90B 350 9.00mm 1.00mm 10

TEXT100B 425 10.00mm 1.00mm 10 TEXT125B 500 12.50mm 1.25mm 11 TEXT150B 600 15.00mm 1.50mm 12 TEXT200B 20.00mm 1.50mm 12

Text Styles TEXT15 through TEXT150 are the standard density text styles defined with font “romans”. Text Styles TEXT15B through TEXT150B are “bold” text styles defined with font “romand”.

Colour assignments for standard text entities must adhere to the MTO CAD Colour Standards/Plot Pen Assignments. Exceptions to the colour assignments are permitted where required for readability.

Page 14: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

8

3.1 Custom AutoCAD Text Font The standard Text Font used is AutoCAD’s “ROMANS” (formerly “SIMLPEX”). In certain cases, additional “special characters” are required and for convenience have been included in an MTO customised Text Font called “MTOENG”. “MTOENG” is based on AutoCAD’s “ROMANS” with the additional characters as documented below. Custom Text Font “MTOENG”

Standard Characters - based on Roman Simplex (romans.shx) abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ 1234567890-=[];'`,./!@#$%^&*()_+{}:"~<>?

Special Characters Custom Special Characters

%%c ø %%150 C

L %%d ° %%151 superscript %%o overscored %%152 subscript

%%p ∀ %%153 P

L %%u underscored %%154 a %%% % %%155 ß %%156 g %%157 µ

Page 15: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

9

4.0 CUSTOM MTO LINE TYPES The figure below illustrates the custom MTO line types. The actual “line-gap” specifications are defined in Section 4.1.

Page 16: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

10

Definitions of Custom MTO Line Types

Line Type Name Line Gap Line Gap Line Gap Line Gap SHORTDASH 2.0 1.0 LONGDASH 18.0 2.0 MEDDASH 9.0 2.0 1MMDOT 0.0 1.0 DASH1 3.0 1.5 COUNTY 15.0 2.0 1.0 2.0 TOWNSHIP 15.0 1.25 3.75 1.25 3.75 1.25 HIGHWAY 15.00 5.0 DISPOSAL 7.5 5.0 R-O-W 20.0 5.0 ROW-PRI 1.0 1.0 ROW-PRU 2.0 2.0 ROW-PLI 4.0 1.0 1.0 1.0 ROW-TLI 2.0 1.0 1.0 1.0 GR-DRIVE 3.75 1.25 GR-ROAD 7.5 2.5 CABLE 20.0 10.0 FENCE 20.0 1.25 2.5 1.25 UTILITY 20.0 1.25 2.5 1.25 2.5 1.25 LANE 8.0 8.0 SLOPE 2.0 0.5 SUBGRADE 5.0 1.0 DITCHRT 6.0 1.0 0.8 1.0 DITCHLT 6.0 1.0 0.8 1.0 0.8 1.0 DITCHM 6.0 1.0 0.8 1.0 0.8 1.0 0.8 1.0 CUTRT 5.0 1.0 0.4 1.0 CUTLT 5.0 1.0 0.4 1.0 0.4 1.0 SLOPERT 10.0 1.0 0.4 1.0 SLOPELT 10.0 1.0 0.4 1.0 0.4 1.0 ROCK 4.0 1.0 MUSKEG 3.0 0.5 EARTH 2.0 0.5 TYPCL 12.5 1.25 2.0 1.25 TYPDASH 3.175 0.6 TYPOG 3.75 1.25 CL1 20.0 1.5 CL2 10.0 1.0 1.0 1.0 CL3 5.0 1.0 1.0 1.0 CL4 2.0 0.75 0.75 0.75 DL1 1.0 0.5 DL2 1.25 1.0 DL3 2.5 1.0

Page 17: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

11

Line Type Name Line Gap Line Gap Line Gap Line Gap DL4 3.0 1.0 DL5 5.0 1.0 0.0 1.0 DL6 8.0 2.0 DL7 2.0 1.0 1.0 1.0 DL8 20.0 20.0 DL9 6.0 1.5 DL11 0.75 0.75 DL12 3.0 0.75 PMK1 3.0 3.0 PMK2 3.0 6.0 PMK3 3.0 9.0 BUSH * patterned line type HEDGE * patterned line type GUIDERAIL * patterned line type RAILROAD1 * patterned line type PITFACEL * patterned line type PITFACER * patterned line type XFENCE * patterned line type

* All measurements are specified in drawing units

Page 18: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

12

5.0 STANDARD PLOT ASSIGNMENTS The table in section 5.1 represents a standard approach that facilitates the use of all 255 AutoCAD colours and supports different plot pen thickness and half-tone/full-tone definitions for various shades of the primary colours. In general, colours 20 through 249 can be assigned to the appropriate plot pens by adhering to the following rule:

*Colour Ending With Plot Pen Thickness (mm) 0 0.30 1 0.20 2 0.25 3 0.40 4 0.50 5 0.60 6 0.75 7 1.00

* Note - there are exceptions (please refer to the colour assignments

table for a complete reference)

Page 19: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

13

5.1 AutoCAD Colour Assignments

The standard colour/pen definitions for full-tone, half-tone, and text style assignments are defined in the table below:

Pen Width 0.30mm 0.20mm 0.25mm 0.40mm 0.50mm 0.60mm 0.75mm 1.00mm 1.25mm 1.50mm

Colour Orange Red Yellow Green Cyan Blue Magenta Red Pink Dark Red

Standard Full-tone

70 7-white

1 2 3 4 5 6 10 11 12

Colour Half-tone

73 23 53 83 133 33 213 223 233 243

Grey Half-tone

9,255 251 254 253 8 252 135 134 145 136

TEXT TEXT25

TEXT15

TEXT20 TEXT30 TEXT35

TEXT45 TEXT50 TEXT60

TEXT75 TEXT90 TEXT100

TEXT125 TEXT150

Additional colour/pen assignments for full-tone plotting are defined below:

COLOUR 0.30mm 0.20mm 0.25mm 0.40mm 0.50mm 0.60mm 0.75mm 1.00mm 1.25mm 1.50mm Red 20 21 22 24 25 26 27 Orange 30 31 32 34 35 36 37 40 41 42 43 44 45 46 47 Yellow 50 51 52 54 55 56 57 60 61 62 63 64 65 66 67 71 72 74 75 76 77 80 81 82 84 85 86 87 Green 90 91 92 93 94 95 96 97 100 101 102 103 104 105 106 107 110 111 112 113 114 115 116 117 120 121 122 123 124 125 126 127 Cyan 130 131 132 137 140 141 142 143 144 146 147 150 151 152 153 154 155 156 157 Blue 160 161 162 163 164 165 166 167 170 171 172 173 174 175 176 177 180 181 182 183 184 185 186 187 Magenta 190 191 192 193 194 195 196 197 200 201 202 203 204 205 206 207 210 211 212 214 215 216 217 220 221 222 224 225 226 227 Red 230 231 232 234 235 236 237 240 241 242 244 245 246 247

Page 20: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

14

5.2 Leroy Equivalent The following table shows the standard pen thickness in millimetres and their approximate Leroy equivalents.

PEN THICKNESS (mm)

PEN THICKNESS (Leroy)

0.20

4x0

0.25

3x0

0.30

00

0.40

0

0.50

1.0

0.60

2.0

0.75

2.5

1.00

3.5

1.25

4.0

1.50

6.0

Page 21: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

15

6.0 STANDARD AutoCAD SYMBOLS To avoid repetition, the standard symbols for use within AutoCAD have not been included in this manual. For a complete symbol library, refer to the manual entitled Ontario Provincial Standard for Roads and Municipal Services. Symbols for Electrical drawings are listed in Volume 4, Section 2000. All others are listed in Volume 3, Section 100.

Page 22: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

16

APPENDIX A: LAYER STANDARDS

Page 23: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

17

Description of Layer Definition Columns The following Appendices detail the standard AutoCAD layer definitions for the various Engineering disciplines in MTO. A brief description of the table columns is provided below: Layer - The AutoCAD Layer Name LineStyle - The standard AutoCAD Line Type assigned to the layer - For layers defined to contain only Symbols, this column indicates “SYMBOLS”. The

standard AutoCAD Line Type assigned to this layer is actually “CONTINUOUS”. - For layers defined to contain only Text entities, this column indicates the standard

IESCAD Text style to be used (ie. TEXT25). The standard AutoCAD Line Type assigned to this layer is actually “CONTINUOUS”.

Full-Tone Color# - The standard AutoCAD Colour that is assigned to this layer Color - Description of the color# Half-Tone Color# - The colour number associated with the layer should the features on the layer be required

to be plotted with a “half-tone” pen. Plotting Color# - The colour number that the layer should be mapped to prior to plotting in order to achieve

the required pen thickness. - This field is in the process of being discontinued. Layer standards defined in February

1997 require this definition and the associated pre-plot layer colour redefinition. Layer standards that have been updated (as of December 1998) no longer require this approach. Eventually this column (and the layer redefinition requirement) will be eliminated altogether for layer standards in all Engineering disciplines.

Pen Thickness (mm) - The pen thickness that entities on this layer should be plotted for “full-size” contract

drawings Description - A description of the entities that should be placed on the layer

Page 24: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

18

Description of Abbreviations Most of the Layer Names in the following tables have been grouped by common major features characteristics. For example:

SP-E-DRN-EM In this layer name, the major feature code category is >DRN=, which represents >Drainage=, of which a number of layers apply to. The following is a general list describing the abbreviations for these major feature categories where layer descriptions do not provide enough detail. Codes not illustrated here are adequately defined by the layer description.

ALI - Alignment BAR - Barrier BASE - Base Material BDY - Property Boundaries BED - Roadbed BIN - Binder Course CBLE - Cable CTR - Contour DRN - Drainage ERTH - Earth FSH - Fishery FTB - Frame & Title Block GND - Ground LAY - Layout MISC - Miscellaneous MON - Survey Monuments MSC - Miscellaneous PIT - Pit Sketch PMK - Pavement Markings RDS - Roads ROW - Right-of-Way SIGN - Signs SUB - Sub Base SUBQ - Sub Surface Material SURF - Surface Material SYM - Symbols TYP - Typicals UTL - Utility VEG - Vegetation WIR - Wiring

Page 25: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-1

LAYER STANDARDS

For

ADVANCED TRAFFIC DRAWINGS

Page 26: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:AT - Advanced Traffic

Status (B): The following abbreviations are used:E - Existing PlanF - FutureN - New Contstruction

Feature (CCC-CC):The feature portion of the layer name is defined by 2 components. - the 1st portion indentifies a type of drawing - the 2nd portion identifies the feature - an optional 3rd portion (-I) is used for Identification Code layers

The following "type of drawing" abbreviations are used:LAY - LayoutWIR - Wiring

Annotation (D): The annotation portion is generally applied at the "feature" level.For example: AT-E-WIR-CABLE-T

ADVANCED TRAFFIC LAYER DEFINITIONS

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

- January 2004 -

app1-advtraf Page 1 of 13

Page 27: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) Description ===============Existing Layout ===============AT-E-LAY-CAB1 6 Magenta - 0.75 VDS CabinetsAT-E-LAY-CAB1-I 6 Magenta - 0.75 VDS CabinetsAT-E-LAY-CAB2 4 Cyan - 0.50 CCTV CabinetsAT-E-LAY-CAB2-I 4 Cyan - 0.50 CCTV CabinetsAT-E-LAY-CAB3 30 Orange 5 0.60 CMS CabinetsAT-E-LAY-CAB3-I 30 Orange 5 0.60 CMS CabinetsAT-E-LAY-CAB4 34 Orange - 0.50 LCS/QWS CabinetsAT-E-LAY-CAB4-I 34 Orange - 0.50 LCS/QWS CabinetsAT-E-LAY-CABC 7 White - 0.30 COMM CabinetsAT-E-LAY-CABC-I 7 White - 0.30 COMM CabinetsAT-E-LAY-CABJ1 14 Red 223 1.00 RMS & VDS CabinetsAT-E-LAY-CABJ1-I 14 Red 223 1.00 RMS & VDS CabinetsAT-E-LAY-CABJ2 14 Red 223 1.00 LCS/QWS & VDS CabinetsAT-E-LAY-CABJ2-I 14 Red 223 1.00 LCS/QWS & VDS CabinetsAT-E-LAY-CABJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS CabinetsAT-E-LAY-CABJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS CabinetsAT-E-LAY-CABJ4 14 Red 223 1.00 CCTV & LCS/QWS CabinetsAT-E-LAY-CABJ4-I 14 Red 223 1.00 CCTV & LCS CabinetsAT-E-LAY-CABJ5 14 Red 223 1.00 CMS & LCS/QWS CabinetsAT-E-LAY-CABJ5-I 14 Red 223 1.00 CMS & LCS/QWS CabinetsAT-E-LAY-CABLE 7 White 0.30 CablesAT-E-LAY-CABP 1 Red 0.20 Power Supply CabinetsAT-E-LAY-CABP-I 1 Red 0.20 Power Supply CabinetsAT-E-LAY-CABP1 6 Magenta 0.75 VDS Cabinet with Power SupplyAT-E-LAY-CABP1-I 6 Magenta 0.75 VDS Cabinet with Power SupplyAT-E-LAY-CABP2 4 Cyan 0.50 CCTV Cab. with Power SupplyAT-E-LAY-CABP2-I 4 Cyan 0.50 CCTV Cab. with Power SupplyAT-E-LAY-CABP3 30 Orange 5 0.60 CMS Cabinet with Power SupplyAT-E-LAY-CABP3-I 30 Orange 5 0.60 CMS Cabinet with Power SupplyAT-E-LAY-CABP4 34 Orange 0.50 LCS/QWS Cabinet with Power Supply

app1-advtraf Page 2 of 13

Page 28: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-E-LAY-CABP4-I 34 Orange 0.50 LCS/QWS Cabinet with Power SupplyAT-E-LAY-CABPJ1 14 Red 223 1.00 RMS & VDS Cab. with Power SupplyAT-E-LAY-CABPJ1-I 14 Red 223 1.00 RMS & VDS Cab. with Power SupplyAT-E-LAY-CABPJ2 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power SupplyAT-E-LAY-CABPJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power SupplyAT-E-LAY-CABPJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power SupplyAT-E-LAY-CABPJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power SupplyAT-E-LAY-CABPJ4 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power SupplyAT-E-LAY-CABPJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power SupplyAT-E-LAY-CABPJ5 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power SupplyAT-E-LAY-CABPJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power SupplyAT-E-LAY-CABTS 7 White 0.30 Traffic Signal Controller CabinetAT-E-LAY-CAER 7 White 0.30 CablesAT-E-LAY-CCTV 4 Cyan 0.50 CCTV CamerasAT-E-LAY-CCTV-I 4 Cyan 0.50 CCTV CamerasAT-E-LAY-COM1 7 White 0.30 Electrical Maintenance HolesAT-E-LAY-COM1-I 7 White 0.30 Electrical Maintenance HolesAT-E-LAY-COM2 7 White 0.30 PedestalsAT-E-LAY-COM2-I 7 White 0.30 PedestalsAT-E-LAY-COM3 7 White 0.30 Junction BoxesAT-E-LAY-COM3-I 7 White 0.30 Junction BoxesAT-E-LAY-COM4 7 White 0.30 Pull BoxesAT-E-LAY-COM4-I 7 White 0.30 Pull BoxesAT-E-LAY-COM5 7 White 0.30 CBAT-E-LAY-COM5-I 7 White 0.30 CBAT-E-LAY-CPAV 7 White 0.30 CablesAT-E-LAY-DCEM 7 White 0.30 Ducts and/or cablesAT-E-LAY-DCSM 7 White 0.30 Ducts and/or cablesAT-E-LAY-DCUG 7 White 0.30 Ducts and/or cablesAT-E-LAY-DCUG-I 7 White 0.30 Ducts and/or cablesAT-E-LAY-DET1 6 Magenta 0.75 Detector LoopsAT-E-LAY-DET1-I 6 Magenta 0.75 Detector LoopsAT-E-LAY-PS3 1 Red 0.20 SubststionsAT-E-LAY-PS3-I 1 Red 0.20 Subststions

app1-advtraf Page 3 of 13

Page 29: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-E-LAY-SIGN1 30 Orange 5 0.60 CMS SignsAT-E-LAY-SIGN1-I 30 Orange 5 0.60 CMS SignsAT-E-LAY-SIGN2 34 Orange 0.50 LCS/QWS SignsAT-E-LAY-SIGN2-I 34 Orange 0.50 LCS/QWS SignsAT-E-LAY-SIGN4 7 White 0.30 Blank Out SignsAT-E-LAY-SIGN4-I 7 White 0.30 Blank Out SignsAT-E-LAY-SUPP1 30 Orange 5 0.60 CMS Overhead StructuresAT-E-LAY-SUPP2 30 Orange 5 0.60 CMS footings.AT-E-LAY-SUPP3 34 Orange 0.50 LCS/QWS Overhead StructuresAT-E-LAY-SUPP4 34 Orange 0.50 LCS/QWS FootingsAT-E-LAY-SUPP6 4 Cyan 0.50 CCTV PolesAT-E-LAY-SUPP7 7 White 0.30 Concrete Pads. ===============Existing Wiring ===============AT-E-WIR-CABLE 7 White 0.30 CablesAT-E-WIR-CABLE-T 7 White 0.30 CablesAT-E-WIR-CAER 7 White 0.30 CablesAT-E-WIR-CAER-T 7 White 0.30 CablesAT-E-WIR-CPAV 7 White 0.30 CablesAT-E-WIR-CPAV-T 7 White 0.30 CablesAT-E-WIR-DCEM 7 White 0.30 Ducts and/or cablesAT-E-WIR-DCEM-T 7 White 0.30 Ducts and/or cablesAT-E-WIR-DCSM 7 White 0.30 Ducts and/or cablesAT-E-WIR-DCSM-T 7 White 0.30 Ducts and/or cablesAT-E-WIR-DCUG 7 White 0.30 Ducts and/or cablesAT-E-WIR-DCUG-I 7 White 0.30 Ducts and/or cablesAT-E-WIR-DCUG-T 7 White 0.30 Ducts and/or cablesAT-E-WIR-DET1 6 Magenta 0.75 Detector LoopsAT-E-WIR-DET1-I 6 Magenta 0.75 Detector Loops ===============Future Layout ===============

app1-advtraf Page 4 of 13

Page 30: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-F-LAY-CAB1 6 Magenta 0.75 VDS CabinetsAT-F-LAY-CAB1-I 6 Magenta 0.75 VDS CabinetsAT-F-LAY-CAB2 4 Cyan 0.50 CCTV CabinetsAT-F-LAY-CAB2-I 4 Cyan 0.50 CCTV CabinetsAT-F-LAY-CAB3 30 Orange 5 0.60 CMS CabinetsAT-F-LAY-CAB3-I 30 Orange 5 0.60 CMS CabinetsAT-F-LAY-CAB4 34 Orange 0.50 LCS/QWS CabinetsAT-F-LAY-CAB4 34 Orange 0.50 LCS/QWS CabinetsAT-F-LAY-CAB4-I 34 Orange 0.50 LCS/QWS CabinetsAT-F-LAY-CAB4-I 34 Orange 0.50 LCS/QWS CabinetsAT-F-LAY-CABC 7 White 0.30 COMM CabinetsAT-F-LAY-CABC-I 7 White 0.30 COMM CabinetsAT-F-LAY-CABJ1 14 Red 223 1.00 RMS & VDS CabinetsAT-F-LAY-CABJ1-I 14 Red 223 1.00 RMS & VDS CabinetsAT-F-LAY-CABJ2 14 Red 223 1.00 LCS/QWS & VDS CabinetsAT-F-LAY-CABJ2-I 14 Red 223 1.00 LCS/QWS & VDS CabinetsAT-F-LAY-CABJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS CabinetsAT-F-LAY-CABJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS CabinetsAT-F-LAY-CABJ4 14 Red 223 1.00 CCTV & LCS/QWS CabinetsAT-F-LAY-CABJ4-I 14 Red 223 1.00 CCTV & LCS/QWS CabinetsAT-F-LAY-CABJ5 14 Red 223 1.00 CMS & LCS/QWS CabinetsAT-F-LAY-CABJ5-I 14 Red 223 1.00 CMS & LCS/QWS CabinetsAT-F-LAY-CABLE 7 White 0.30 CablesAT-F-LAY-CABP 1 Red 0.20 Power Supply CabinetsAT-F-LAY-CABP-I 1 Red 0.20 Power Supply CabinetsAT-F-LAY-CABP1 6 Magenta 0.75 VDS Cabinet with Power SupplyAT-F-LAY-CABP1-I 6 Magenta 0.75 VDS Cabinet with Power SupplyAT-F-LAY-CABP2 4 Cyan 0.50 CCTV Cab. with Power SupplyAT-F-LAY-CABP2-I 4 Cyan 0.50 CCTV Cab. with Power SupplyAT-F-LAY-CABP3 30 Orange 5 0.60 CMS Cabinet with Power SupplyAT-F-LAY-CABP3-I 30 Orange 5 0.60 CMS Cabinet with Power SupplyAT-F-LAY-CABP4 34 Orange LCS/QWS Cabinet with Power SupplyAT-F-LAY-CABP4-I 34 Orange LCS/QWS Cabinet with Power SupplyAT-F-LAY-CABPJ1 14 Red 223 1.00 RMS & VDS Cab. with Power Supply

app1-advtraf Page 5 of 13

Page 31: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-F-LAY-CABPJ1-I 14 Red 223 1.00 RMS & VDS Cab. with Power SupplyAT-F-LAY-CABPJ2 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power SupplyAT-F-LAY-CABPJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power SupplyAT-F-LAY-CABPJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power SupplyAT-F-LAY-CABPJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power SupplyAT-F-LAY-CABPJ4 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power SupplyAT-F-LAY-CABPJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power SupplyAT-F-LAY-CABPJ5 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power SupplyAT-F-LAY-CABPJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power SupplyAT-F-LAY-CABTS 7 White 0.30 Traffic Signal Controller CabinetAT-F-LAY-CAER 7 White 0.30 CablesAT-F-LAY-CCTV 4 Cyan 0.50 CCTV CamerasAT-F-LAY-CCTV-I 4 Cyan 0.50 CCTV CamerasAT-F-LAY-COM1 7 White 0.30 Electrical Maintenance HolesAT-F-LAY-COM1-I 7 White 0.30 Electrical Maintenance HolesAT-F-LAY-COM2 7 White 0.30 PedestalsAT-F-LAY-COM2-I 7 White 0.30 PedestalsAT-F-LAY-COM3 7 White 0.30 Junction BoxesAT-F-LAY-COM3-I 7 White 0.30 Junction BoxesAT-F-LAY-COM4 7 White 0.30 Pull BoxesAT-F-LAY-COM4-I 7 White 0.30 Pull BoxesAT-F-LAY-COM5 7 White 0.30 CBAT-F-LAY-COM5-I 7 White 0.30 CBAT-F-LAY-CPAV 7 White 0.30 CablesAT-F-LAY-DCEM 7 White 0.30 Ducts and/or cablesAT-F-LAY-DCSM 7 White 0.30 Ducts and/or cablesAT-F-LAY-DCUG 7 White 0.30 Ducts and/or cablesAT-F-LAY-DCUG-D 7 White 0.30 Ducts and/or cablesAT-F-LAY-DCUG-I 7 White 0.30 Ducts and/or cablesAT-F-LAY-DET1 6 Magenta 0.75 Detector LoopsAT-F-LAY-DET1-I 6 Magenta 0.75 Detector LoopsAT-F-LAY-SIGN1 30 Orange 5 0.60 CMS SignsAT-F-LAY-SIGN1-I 30 Orange 5 0.60 CMS SignsAT-F-LAY-SIGN2 34 Orange 0.50 LCS/QWS Signs

app1-advtraf Page 6 of 13

Page 32: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-F-LAY-SIGN2-I 34 Orange 0.50 LCS/QWS SignsAT-F-LAY-SIGN4 7 White 0.30 Blank Out SignsAT-F-LAY-SIGN4-I 7 White 0.30 Blank Out SignsAT-F-LAY-SUPP1 30 Orange 5 0.60 CMS Overhead StructuresAT-F-LAY-SUPP2 30 Orange 5 0.60 CMS footings.AT-F-LAY-SUPP3 34 Orange 0.50 LCS/QWS Overhead StructuresAT-F-LAY-SUPP4 34 Orange 0.50 LCS/QWS FootingsAT-F-LAY-SUPP6 4 Cyan 0.50 CCTV PolesAT-F-LAY-SUPP7 7 White 0.30 Concrete Pads. ===============Future Wiring ===============AT-F-WIR-CABLE 7 White 0.30 CablesAT-F-WIR-CABLE-T 7 White 0.30 CablesAT-F-WIR-CAER 7 White 0.30 CablesAT-F-WIR-CAER-T 7 White 0.30 CablesAT-F-WIR-CCTV 4 Cyan 0.50 CCTV CamerasAT-F-WIR-CCTV-I 4 Cyan 0.50 CCTV CamerasAT-F-WIR-COM1 7 White 0.30 Electrical Maintenance HolesAT-F-WIR-COM1-I 7 White 0.30 Electrical Maintenance HolesAT-F-WIR-COM2 7 White 0.30 PedestalsAT-F-WIR-COM2-I 7 White 0.30 PedestalsAT-F-WIR-COM3 7 White 0.30 Junction BoxesAT-F-WIR-COM3-I 7 White 0.30 Junction BoxesAT-F-WIR-COM4 7 White 0.30 Pull BoxesAT-F-WIR-COM4-I 7 White 0.30 Pull BoxesAT-F-WIR-COM5 7 White 0.30 CBAT-F-WIR-COM5-I 7 White 0.30 CBAT-F-WIR-CPAV 7 White 0.30 CablesAT-F-WIR-CPAV-T 7 White 0.30 CablesAT-F-WIR-DCEM 7 White 0.30 Ducts and/or cablesAT-F-WIR-DCEM-T 7 White 0.30 Ducts and/or cablesAT-F-WIR-DCSM 7 White 0.30 Ducts and/or cables

app1-advtraf Page 7 of 13

Page 33: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-F-WIR-DCSM-T 7 White 0.30 Ducts and/or cablesAT-F-WIR-DCUG 7 White 0.30 Ducts and/or cablesAT-F-WIR-DCUG-I 7 White 0.30 Ducts and/or cablesAT-F-WIR-DCUG-T 7 White 0.30 Ducts and/or cablesAT-F-WIR-DET1 6 Magenta 0.75 Detector LoopsAT-F-WIR-DET1-I 6 Magenta 0.75 Detector LoopsAT-F-WIR-PS2 3 Green 0.40 Ground RodsAT-F-WIR-PS3 1 Red 0.20 SubststionsAT-F-WIR-PS3-I 1 Red 0.20 SubststionsAT-F-WIR-SIGN1 30 Orange 5 0.60 CMS SignsAT-F-WIR-SIGN1-I 30 Orange 5 0.60 CMS SignsAT-F-WIR-SIGN2 34 Orange 0.50 LCS/QWS SignsAT-F-WIR-SIGN2-I 34 Orange 0.50 LCS/QWS SignsAT-F-WIR-SIGN4 7 White 0.30 Blank Out SignsAT-F-WIR-SIGN4-I 7 White 0.30 Blank Out Signs

app1-advtraf Page 8 of 13

Page 34: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) Description ===============New Layout ===============AT-N-LAY-CAB1 6 Magenta 0.75 VDS CabinetsAT-N-LAY-CAB1-I 6 Magenta 0.75 VDS CabinetsAT-N-LAY-CAB2 4 Cyan 0.50 CCTV CabinetsAT-N-LAY-CAB2-I 4 Cyan 0.50 CCTV CabinetsAT-N-LAY-CAB3 30 Orange 5 0.60 CMS CabinetsAT-N-LAY-CAB3-I 30 Orange 5 0.60 CMS CabinetsAT-N-LAY-CAB4 34 Orange 0.50 LCS/QWS CabinetsAT-N-LAY-CAB4-I 34 Orange 0.50 LCS/QWS CabinetsAT-N-LAY-CABC 7 White 0.30 COMM CabinetsAT-N-LAY-CABC-I 7 White 0.30 COMM CabinetsAT-N-LAY-CABJ1 14 Red 223 1.00 RMS & VDS CabinetsAT-N-LAY-CABJ1-I 14 Red 223 1.00 RMS & VDS CabinetsAT-N-LAY-CABJ2 14 Red 223 1.00 LCS/QWS & VDS CabinetsAT-N-LAY-CABJ2-I 14 Red 223 1.00 LCS/QWS & VDS CabinetsAT-N-LAY-CABJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS CabinetsAT-N-LAY-CABJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS CabinetsAT-N-LAY-CABJ4 14 Red 223 1.00 CCTV & LCS/QWS CabinetsAT-N-LAY-CABJ4-I 14 Red 223 1.00 CCTV & LCS/QWS CabinetsAT-N-LAY-CABJ5 14 Red 223 1.00 CMS & LCS/QWS CabinetsAT-N-LAY-CABJ5-I 14 Red 223 1.00 CMS & LCS/QWS CabinetsAT-N-LAY-CABLE 7 White 0.30 CablesAT-N-LAY-CABLE-D 7 White 0.30 CablesAT-N-LAY-CABLE-T 7 White 0.30 CablesAT-N-LAY-CABP 1 Red 0.20 Power Supply CabinetsAT-N-LAY-CABP-I 1 Red 0.20 Power Supply CabinetsAT-N-LAY-CABP1 6 Magenta 0.75 VDS Cabinet with Power SupplyAT-N-LAY-CABP1-I 6 Magenta 0.75 VDS Cabinet with Power SupplyAT-N-LAY-CABP2 4 Cyan 0.50 CCTV Cab. with Power SupplyAT-N-LAY-CABP2-I 4 Cyan 0.50 CCTV Cab. with Power SupplyAT-N-LAY-CABP3 30 Orange 5 0.60 CMS Cabinet with Power Supply

app1-advtraf Page 9 of 13

Page 35: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-N-LAY-CABP3-I 30 Orange 5 0.60 CMS Cabinet with Power SupplyAT-N-LAY-CABP4 34 Orange 0.50 LCS/QWS Cabinet with Power SupplyAT-N-LAY-CABP4-I 34 Orange 0.50 LCS/QWS Cabinet with Power SupplyAT-N-LAY-CABPJ1 14 Red 223 1.00 RMS & VDS Cab. with Power SupplyAT-N-LAY-CABPJ1-I 14 Red 223 1.00 RMS & VDS Cab. with Power SupplyAT-N-LAY-CABPJ2 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power SupplyAT-N-LAY-CABPJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power SupplyAT-N-LAY-CABPJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power SupplyAT-N-LAY-CABPJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power SupplyAT-N-LAY-CABPJ4 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power SupplyAT-N-LAY-CABPJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power SupplyAT-N-LAY-CABPJ5 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power SupplyAT-N-LAY-CABPJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power SupplyAT-N-LAY-CABTS 7 White 0.30 Traffic Signal Controller CabinetAT-N-LAY-CAER 7 White 0.30 CablesAT-N-LAY-CAER-D 7 White 0.30 CablesAT-N-LAY-CAER-T 7 White 0.30 CablesAT-N-LAY-CCTV 4 Cyan 0.50 CCTV CamerasAT-N-LAY-CCTV-I 4 Cyan 0.50 CCTV CamerasAT-N-LAY-CCTV-T 4 Cyan 0.50 CCTV CamerasAT-N-LAY-COM1 7 White 0.30 Electrical Maintenance HolesAT-N-LAY-COM1-D 7 White 0.30 Electrical Maintenance HolesAT-N-LAY-COM1-I 7 White 0.30 Electrical Maintenance HolesAT-N-LAY-COM2 7 White 0.30 PedestalsAT-N-LAY-COM2-D 7 White 0.30 PedestalsAT-N-LAY-COM2-I 7 White 0.30 PedestalsAT-N-LAY-COM3 7 White 0.30 Junction BoxesAT-N-LAY-COM3-D 7 White 0.30 Junction BoxesAT-N-LAY-COM3-I 7 White 0.30 Junction BoxesAT-N-LAY-COM4 7 White 0.30 Pull BoxesAT-N-LAY-COM4-D 7 White 0.30 Pull BoxesAT-N-LAY-COM4-I 7 White 0.30 Pull BoxesAT-N-LAY-COM5 7 White 0.30 CBAT-N-LAY-COM5-I 7 White 0.30 CB

app1-advtraf Page 10 of 13

Page 36: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-N-LAY-CPAV 7 White 0.30 CablesAT-N-LAY-CPAV-D 7 White 0.30 CablesAT-N-LAY-CPAV-T 7 White 0.30 CablesAT-N-LAY-DCEM 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCEM-D 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCEM-T 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCSM 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCSM-D 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCSM-T 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCUG 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCUG-D 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCUG-I 7 White 0.30 Ducts and/or cablesAT-N-LAY-DCUG-T 7 White 0.30 Ducts and/or cablesAT-N-LAY-DET1 6 Magenta 0.75 Detector LoopsAT-N-LAY-DET1-I 6 Magenta 0.75 Detector LoopsAT-N-LAY-MISC1 7 White 0.30 GuysAT-N-LAY-PS1 1 Red 0.20 Power Supply PolesAT-N-LAY-PS2 3 Green 0.40 Ground RodsAT-N-LAY-PS3 1 Red 0.20 SubststionsAT-N-LAY-PS3-I 1 Red 0.20 SubststionsAT-N-LAY-SIGN1 30 Orange 5 0.60 CMS SignsAT-N-LAY-SIGN1-I 30 Orange 5 0.60 CMS SignsAT-N-LAY-SIGN2 34 Orange 0.50 LCS/QWS SignsAT-N-LAY-SIGN2-I 34 Orange 0.50 LCS/QWS SignsAT-N-LAY-SIGN4 7 White 0.30 Blank Out SignsAT-N-LAY-SIGN4-I 7 White 0.30 Blank Out SignsAT-N-LAY-SUPP1 30 Orange 5 0.60 CMS Overhead StructuresAT-N-LAY-SUPP2 30 Orange 5 0.60 CMS footings.AT-N-LAY-SUPP2-D 30 Orange 5 0.60 CMS footings.AT-N-LAY-SUPP3 34 Orange 0.50 LCS/QWS Overhead StructuresAT-N-LAY-SUPP4 34 Orange 0.50 LCS/QWS FootingsAT-N-LAY-SUPP4-D 34 Orange 0.50 LCS/QWS FootingsAT-N-LAY-SUPP6 4 Cyan 0.50 CCTV PolesAT-N-LAY-SUPP7 7 White 0.30 Concrete Pads.

app1-advtraf Page 11 of 13

Page 37: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-N-LAY-SUPP7-D 7 White 0.30 Concrete Pads. ===============New Wiring ===============AT-N-WIR-CABLE 7 White 0.30 CablesAT-N-WIR-CABLE-T 7 White 0.30 CablesAT-N-WIR-CAER 7 White 0.30 CablesAT-N-WIR-CAER-T 7 White 0.30 CablesAT-N-WIR-CCTV 4 Cyan 0.50 CCTV CamerasAT-N-WIR-CCTV-I 4 Cyan 0.50 CCTV CamerasAT-N-WIR-COM1 7 White 0.30 Electrical Maintenance HolesAT-N-WIR-COM1-I 7 White 0.30 Electrical Maintenance HolesAT-N-WIR-COM2 7 White 0.30 PedestalsAT-N-WIR-COM2-I 7 White 0.30 PedestalsAT-N-WIR-COM3 7 White 0.30 Junction BoxesAT-N-WIR-COM3-I 7 White 0.30 Junction BoxesAT-N-WIR-COM4 7 White 0.30 Pull BoxesAT-N-WIR-COM4-I 7 White 0.30 Pull BoxesAT-N-WIR-COM5 7 White 0.30 CBAT-N-WIR-COM5-I 7 White 0.30 CBAT-N-WIR-CPAV 7 White 0.30 CablesAT-N-WIR-CPAV-T 7 White 0.30 CablesAT-N-WIR-DCEM 7 White 0.30 Ducts and/or cablesAT-N-WIR-DCEM-T 7 White 0.30 Ducts and/or cablesAT-N-WIR-DCSM 7 White 0.30 Ducts and/or cablesAT-N-WIR-DCSM-T 7 White 0.30 Ducts and/or cablesAT-N-WIR-DCUG 7 White 0.30 Ducts and/or cablesAT-N-WIR-DCUG-I 7 White 0.30 Ducts and/or cablesAT-N-WIR-DCUG-T 7 White 0.30 Ducts and/or cablesAT-N-WIR-DET1 6 Magenta 0.75 Detector LoopsAT-N-WIR-DET1-I 6 Magenta 0.75 Detector LoopsAT-N-WIR-PS2 3 Green 0.40 Ground RodsAT-N-WIR-PS3 1 Red 0.20 Subststions

app1-advtraf Page 12 of 13

Page 38: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlotting Color#

Pen Thickness

(mm) DescriptionAT-N-WIR-PS3-I 1 Red 0.20 SubststionsAT-N-WIR-SIGN1 30 Orange 5 0.60 CMS SignsAT-N-WIR-SIGN1-I 30 Orange 5 0.60 CMS SignsAT-N-WIR-SIGN2 34 Orange 0.50 LCS/QWS SignsAT-N-WIR-SIGN2-I 34 Orange 0.50 LCS/QWS SignsAT-N-WIR-SIGN4 7 White 0.30 Blank Out SignsAT-N-WIR-SIGN4-I 7 White 0.30 Blank Out Signs

app1-advtraf Page 13 of 13

Page 39: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-2

LAYER STANDARDS

For

ELECTRICAL DESIGN DRAWINGS

Page 40: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:EL - Electrical

Status (B): The following abbreviations are used:G - General (non-feature specific)E - Existing PlanF - FutureN - New ContstructionR - Removals

Feature (CCC-CC): The feature portion of the layer name is defined as follows: For example: EL-N-CTRLCAB

Annotation (D): The annotation portion is generally applied at the "feature" level.For example: EL-E-DET-T

NOTES: 1) * Design Line - please refer to OPSD 2001.010 for the appropriate line patterning 2) Templates are distributed with this manual 3) Symbols are included in the menu (refer to OPSD 2001 for symbol definitions)

ELECTRICAL DESIGN LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

app2-electrical Page 1 of 11

Page 41: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description=============General Layers=============BORDER CONTINUOUS 6 Magenta 135 0.75 Border - Frame - Title BlockDWGINFO CONTINUOUS 7 White 9 NO PLOT Drawing InfoVPORTS CONTINUOUS 4 Cyan 8 NO PLOT View PortsEL-G-25MM CONTINUOUS 22 Red shade 254 0.25 General Line 0.25mmEL-G-40MM CONTINUOUS 63 Light yellow 253 0.40 General Line 0.40mmEL-G-50MM CONTINUOUS 4 Cyan 8 0.50 General Line 0.50mmEL-G-75MM CONTINUOUS 6 Magenta 135 0.75 General Line 0.75mmEL-G-25MM-CL1 CL1 22 Red shade 254 0.25 General CL1EL-G-25MM-CL2 CL2 22 Red shade 254 0.25 General CL2EL-G-25MM-DL1 DL1 92 Green shade 254 0.25 General DL1EL-G-25MM-DL2 DL2 132 Cyan shade 254 0.25 General DL2EL-G-40MM-DL3 DL3 63 Light yellow 253 0.40 General DL3EL-G-50MM-DL4 DL4 134 Light blue 8 0.50 General DL4EL-G-50MM-DL5 DL5 4 Cyan 8 0.50 General DL5EL-G-CONS CONTINUOUS 8 Gray 8 NO PLOT Construction (working) LineEL-G-DIM CONTINUOUS 132 Cyan 254 0.25 General DimensionsEL-G-HATCH CONTINUOUS 1 Red 251 0.20 General Hatch Pattern EL-G-TEXT TEXT 3 White 9 varies General Text=============Existing Conditions=============EL-E-CTRLCAB SYMBOL 80 Light green 9 0.30 T.S. Controller Cabinet

T.S. Controller Cabinet with Adjacent Power SupplyT.S. Controller Cabinet with E.C.I.BT.S. Controller Cabinet Pad or Base Mounted

EL-E-CTRLCAB-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-CTRLCAB-IDC SYMBOL 80 Light yellow 9 0.30 Identification CodeEL-E-CTRLCAB-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 2 of 11

Page 42: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-E-DET SYMBOL 80 Light green 9 0.30 Simple Loop

Duplex LoopPowerhead LoopDiamond LoopProbe Vehicle DetectorMicrowave - Lightwave - Sonic Vehicle DetectorPedestrian Pushbutton

EL-E-DET-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-DET-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-DET-T TEXT25 7 White 9 0.30 Text Size 2.5mm

EL-E-DUCT *CONTINUOUS 3 Green 9 0.40Existing Ducts/Cables To Remain In Place, *continuous line with labels

EL-E-DUCT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-DUCT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-FOOT SYMBOL 80 Light green 9 0.30 Concrete Pad/Footing In Earth Or Rock

Footing in StructureSign Footing

EL-E-FOOT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-FOOT-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-FOOT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-GUY SYMBOL 80 Brown 9 0.30 Simple Guy With Single Anchor

Double Guy With Single AnchorDouble Guy With Double Anchor

Single Guy With Sidewalk Strut and Single AnchorEL-E-GUY-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-GUY-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-LUM SYMBOL 80 Light green 9 0.30 Luminaires

Luminaires With BracketFloodlight LuminairesUnderpass or Surface Mounted LuminairesObstruction or Navigation Luminaires

app2-electrical Page 3 of 11

Page 43: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-E-LUM-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-LUM-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-LUM-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-MH CONTINUOUS 80 Light green 9 0.30 Electrical Maintenance Holes

Junction Box (Embedded or Surface Mounted)Handhole - Underground

EL-E-MH-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-MH-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-MH-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-POLE CONTINUOUS 80 Light green 9 0.30 PolesEL-E-POLE-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-POLE-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-POLE-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-PWRSUPP SYMBOL 80 Light green 254 0.30 Power supply equipment

TransformerGeneratorPse - pad and/or base mountedPhotoelectric controller

EL-E-PWRSUPP-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-PWRSUPP-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-PWRSUPP-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-E-TSDEV SYMBOL 80 Light green 9 0.30 Illuminated Traffic Sign - Single Side

Illuminated Traffic Sign - Double SideIlluminated Traffic Sign with Flasher BeaconFlasher BeaconFlasher MechanismTraffic Sign - Overhead with Static SignTraffic Sign - Overhead with Changeable Message SignTraffic Sign - Overhead With Lane Control Signs

EL-E-TSDEV-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-TSDEV-IDC SYMBOL 80 Light green 9 0.30 Identification CodeEL-E-TSDEV-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 4 of 11

Page 44: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-E-TSHEAD SYMBOL 80 Light green

90.30 Highway Signal Head - 300mm Red 200mm Amber

and Green Lenses With BackboardHighway Signal Head - All 300mm Lenses with backboardStandard signal head - all 200mm lensesStandard signal head - all 200mm lenses with backboardSpecial signal heads with backboardPedestrian signal head - two section typePedestrian signal head - single section fibre optic typeSignal head with backboard - span wire mountingSignal heads with backboard and mast armSignal head with backboard and double arm bracket

EL-E-TSHEAD-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-E-TSHEAD-T TEXT25 7 White 9 0.30 Text Size 2.5mm=============Future Conditions=============EL-F-DET DL1 22 Light red 254 0.25 Simple Loop

Duplex LoopPowerhead LoopDiamond LoopProbe Vehicle DetectorMicrowave - Lightwave - Sonic Vehicle DetectorPedestrian Pushbutton

EL-F-DET-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-F-DET-IDC SYMBOL 20 Light red 9 0.30 Identification CodeEL-F-DET-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-F-DUCT DL15 63 Light yellow 253 0.40 Spare ducts for future useEL-F-DUCT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-F-DUCT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-F-CBLE-SLOT DL13 63 Light yellow 253 0.40 Cables - In Pavement SlotEL-F-CBLE-SLOT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-F-CBLE-SLOT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-F-FOOT DL1 22 Light red 254 0.25 Concrete Pad/Footing In Earth Or Rock

Footing in StructureSign Footing

EL-F-FOOT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-F-FOOT-IDC SYMBOL 20 Light red 9 0.30 Identification Code

app2-electrical Page 5 of 11

Page 45: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-F-FOOT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-F-MH DL1 22 Light red 254 0.25 Electrical Maintenance Holes

Junction box - embedded or surface mountedHandhole underground

app2-electrical Page 6 of 11

Page 46: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-F-MH-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-F-MH-IDC SYMBOL 20 Light red 9 0.30 Identification CodeEL-F-MH-T TEXT25 7 White 9 0.30 Text Size 2.5mm=============New Construction=============EL-N-CBLE-AERL DL14 4 Cyan 8 0.50 Cables - AerialEL-N-CBLE-AERL-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-CBLE-AERL-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-CBLE-DB DL4 64 Light blue 8 0.50 Cable Direct BuriedEL-N-CBLE-DB-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-CBLE-DB-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-CBLE-EXDT DL10 92 Green shade 134 0.25 Cables - Installed In Existing DuctsEL-N-CBLE-EXDT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-CBLE-EXDT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-CBLE-SLOT DL13 4 Cyan 8 0.50 Cables - In Pavement SlotEL-N-CBLE-SLOT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-CBLE-SLOT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-CBLE-SPLC CONTINUOUS 50 Light yellow 9 0.30 In Line Cable Splice

Tap Cable SpliceWiring EnclosureEquipment Items

EL-N-CBLE-SPLC-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-CBLE-SPLC-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-CBLE-SPLC-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-DUCT-EMBD DL11 92 Green shade 134 1.00 Ducts - Embedded.EL-N-DUCT-EMBD-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-DUCT-EMBD-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-DUCT-SMTD DL12 63 Light yellow 134 1.00 Ducts - Surface Mounted.EL-N-DUCT-SMTD-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-DUCT-SMTD-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-DUCT-UGD CONTINUOUS 4 Cyan 134 1.00 Ducts - UndergroundEL-N-CBR CONTINUOUS 21 Red shade 251 0.25 Cable Bricks

app2-electrical Page 7 of 11

Page 47: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-N-DUCT-UGD-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-DUCT-UGD-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code or Reference PointEL-N-DUCT-UGD-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-DUCT CONTINUOUS 4 Cyan 8 0.50 Ducts And/Or CablesEL-N-DUCT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-DUCT-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-DUCT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-COMM SYMBOL 50 Light yellow 9 0.30 Communications Pedestal with IDC

Coaxial Cable Power Supply with IDCCoaxial Cable Amplifier, AGC with IDCCoaxial Cable Amplifier, MGC with IDCCoaxial Cable Amplifier,AGC & MGC with IDCTemporarily ,all symbols for Advance Traffic Management System

EL-N-COMM-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-COMM-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-COMM-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-CTRLCAB SYMBOL 50 Light yellow 9 0.30 Controller Cabinet

Controller cabinet with adjacent power supplyController cabinet with E.C.I.B

EL-N-CTRLCAB-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-CTRLCAB-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-CTRLCAB-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-DET SYMBOL 50 Light yellow 9 0.30 Simple Loop

Duplex loopPowerhead loopDiamond loopProbe vehicle detectorMicrowave - lightwave - sonic vehicle detectorPedestrian pushbutton

EL-N-DET-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-DET-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-DET-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 8 of 11

Page 48: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-N-FOOT SYMBOL 50 Light yellow 9 0.30 Concrete Pad/Footing In Earth Or Rock

Footing in structureSign footing

EL-N-FOOT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-FOOT-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-FOOT-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-GRND SYMBOL 50 Light yellow 9 0.30 Ground Rods

Ground ElectrodesEL-N-GRND-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-GRND-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-GUY SYMBOL 50 Light yellow 9 0.30 Simple Guy With Single Anchor

Double guy with single anchorDouble guy with double anchorSingle guy with sidewalk strut and single anchor

EL-N-GUY-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-GUY-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-LUM SYMBOL 50 Light Yellow 9 0.30 Luminaires

Luminaires With BracketFloodlight LuminairesUnderpass or Surface Mounted Luminaires

Luminaires (Number Shown Indicates Luminaire Location on High Mast with Respect to Pole Handle)Obstruction or Navigation Luminaires

EL-N-LUM-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-LUM-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-LUM-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-MH SYMBOL 50 Light yellow 9 0.30 Electrical Maintenance Holes

Junction box - embedded or surface mountedHandhole underground

EL-N-MH DL1 50 Light yellow 9 0.30 Electrical Maintenance HolesJunction box - embedded or surface mountedHandhole underground

app2-electrical Page 9 of 11

Page 49: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-N-MH-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-MH-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-MH-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-POLE SYMBOL 50 Light yellow 9 0.30 PolesEL-N-POLE DL1 50 Light yellow 9 0.30 PolesEL-N-POLE-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-POLE-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code For PolesEL-N-POLE-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-PWRSUPP SYMBOL 50 Light yellow 9 0.30 Power Supply Equipment

TransformerGeneratorPhotoelectric controllerPSE - pad and/or base mounted

EL-N-PWRSUPP-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-PWRSUPP-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-PWRSUPP-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-TSDEV SYMBOL 50 Light yellow 9 0.30 Illuminated Traffic Sign - Single Side

Illuminated Traffic Sign - Double SideIlluminated traffic sign with flasher beaconFlasher beaconFlasher beacon (4-way)Flasher mechanism

Traffic sign - overhead sign support with static signTraffic sign - overhead sign support with changeable message signTraffic sign - overhead sign support with lane control signs

EL-N-TSDEV-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-TSDEV-IDC SYMBOL 50 Light yellow 9 0.30 Identification CodeEL-N-TSDEV-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 10 of 11

Page 50: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionEL-N-TSHEAD SYMBOL 50 Light yellow 9 0.30 Highway Signal Heads

Special signal heads with backboardPedestrian signal headsSignal head with backboard - span wire mountingSignal heads with backboard and mast armTS Arms & Bracket

EL-N-TSHEAD-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-N-TSHEAD-IDC SYMBOL 50 Light Yellow 9 0.30 Identification CodeEL-N-TSHEAD-T TEXT25 7 White 9 0.30 Text Size 2.5mmEL-N-LIMIT CONTINUOUS 6 Magenta 135 0.75 Electrical Work Limit===================Removals===================

EL-R-CBLE-RMVL *CONTINUOUS 63 Light yellow 9 0.40Existing Ducts And/Or Cables To Be Removed, *continuous line with labels

EL-R-CBLE-ABND *CONTINUOUS 63 Light yellow 9 0.40Existing Ducts and/or Cables to be Abandoned, *continuous line with labels

EL-R-EQPT SYMBOL 130 Cyan shade 9 0.30 Symbol for removal, symbol for abandonEL-R-EQPT-D CONTINUOUS 132 Cyan shade 254 0.25 DimensionsEL-R-EQPT-IDC SYMBOL 130 Light yellow 9 0.30 Identification CodeEL-R-EQPT-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 11 of 11

Page 51: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-3

LAYER STANDARDS

For

ENVIRONMENTAL DRAWINGS

Page 52: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:EN - Environmental

Status (B): The following abbreviations are used:N - New Construction

Feature (CCC-CC): The feature portion of the layer name is defined by 2 components. - the 1st portion indentifies a feature group - the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:BAR - Barriers GND - GroundDRN - Drainage UTL - UtiltiesFSH - Fish Related VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature" level.

For example: EN-N-GND-CP-P

* NOTE: Drawing details for layers marked with "*" will be provided in the Fisheries Technical Manual. Part II, available in 1997

ENVIRONMENTAL LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

app3-environ Page 1 of 4

Page 53: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) Description ============== Barrier Layers ==============EN-N-BAR-BERM Symbol 7 White 4 1 Berm BarrierEN-N-BAR-HDSB Symbol 2 Yellow 4 1 Heavy Duty Straw Bale BarrierEN-N-BAR-HDSF Symbol 6 Magenta 4 1 Heavy Duty Silt Fence BarrierEN-N-BAR-LDSB Symbol 7 Yellow 7 0 Light Duty Straw Bale Barrier EN-N-BAR-LDSF Symbol 6 Magenta 7 0 Light Duty Silt Fence BarrierEN-N-BAR-SAND Symbol 5 Blue 4 1 Sandbag Barrier ============== Drainage Layers ==============EN-N-DRN-BVB Continuous 1 Red 7 0 Beaver BafflerEN-N-DRN-CHUT Continuous 5 Blue 4 1 ChuteEN-N-DRN-DDP Continuous 2 Yellow 5 1 Dry Detention PondEN-N-DRN-DWT Continuous 3 Green 5 1 Dewatering TrapEN-N-DRN-FCRC Symbol 1 Red 4 1 Temporary Rock Flow Check, Flat Bottom

or ChannelEN-N-DRN-FCRV Symbol 1 Red 4 1 Temporary Rock Flow Check, V DitchEN-N-DRN-FCSB Symbol 5 Blue 4 1 Sandbag Flow CheckEN-N-DRN-FCSF Symbol 6 Magenta 4 1 Silt Fence Flow CheckEN-N-DRN-FCSW Symbol 2 Yellow 4 1 Straw Bale Flow CheckEN-N-DRN-GSF Continuous 4 Cyan 7 0 Groundwater Spring FeedEN-N-DRN-GWF Continuous 5 Blue 7 0 Groundwater Well FeedEN-N-DRN-INB Continuous 3 Green 4 1 Infiltration BasinEN-N-DRN-INT Continuous Orange 4 1 Infiltration TrenchEN-N-DRN-TRCR Continuous Orange 5 1 Turbidity CurtainEN-N-DRN-WDP Continuous 5 Blue 5 1 Wet Detention PondEN-N-DRN-WET Symbol 4 Cyan 4 1 WetlandEN-N-DRN-XST Symbol Orange 4 1 Excavated Sediment Trap

app3-environ Page 2 of 4

Page 54: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) Description ============== Fish Related Layers ==============EN-N-FSH-AREF* Continuous Artificial ReefsEN-N-FSH-ASPS* Continuous Artificial Spawning ShoalsEN-N-FSH-BLP* Continuous Blast PoolsEN-N-FSH-BPS* Symbol Boulder Placement in StreamsEN-N-FSH-BSS* Continuous Bass Spawning BoxEN-N-FSH-CHBD* Continuous Beaded ChannelEN-N-FSH-FW* Continuous FishwaysEN-N-FSH-GCD* Continuous Gravel Catchment DevicesEN-N-FSH-GRYN* Continuous GroynesEN-N-FSH-LGCS* Continuous Log Crib StucturesEN-N-FSH-LJDC* Symbol Log Jam Structure and Debris CollectorEN-N-FSH-MGB* Continuous Migration BarrierEN-N-FSH-PACV* Symbol Pallet Cover StructuresEN-N-FSH-RFB* Continuous Riffle BuildingEN-N-FSH-RIPL* Continuous Log Rip-RapEN-N-FSH-RIPR* Continuous Rock Rip-RapEN-N-FSH-SCLG* Continuous Scour LogsEN-N-FSH-SLBC* Symbol Submerged Log Bank CoverEN-N-FSH-SPB* Continuous Spawning BedEN-N-FSH-TBS* Symbol Tree and Brush SheltersEN-N-FSH-WGD* Continuous Wing Deflectors ==============Ground Layers ==============EN-N-GND-CP-P Continuous 6 Magenta 4 1 Contaminated PropertyEN-N-GND-EXM-P Continuous 1 Red 4 1 Excess Materials

app3-environ Page 3 of 4

Page 55: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) Description ==============Utilities Layers ==============EN-N-UTL-SPT Continuous Orange 7 0 Septic TanksEN-N-UTL-WAWE Continuous 4 Cyan 7 0 Water Wells ==============Vegetation Layers ==============EN-N-VEG-AAVG* Symbol Artificial Aquatic VegetationEN-N-VEG-AVG* Symbol Aquatic VegetationEN-N-VEG-CNT Symbol 1 Red 5 1 Coniferous TreesEN-N-VEG-CRF-P Hatch Pattern 1 Red 4 1 Coniferous ReforestationEN-N-VEG-DRF-P Hatch Pattern 3 Green 4 1 Deciduous ReforestationEN-N-VEG-DTR Symbol 3 Green 5 1 Deciduous TreesEN-N-VEG-ECB-P Hatch Pattern 1 Red 7 0 Erosion Control BlanketEN-N-VEG-MRF-P Hatch Pattern 4 Cyan 4 1 Mixed ReforestationEN-N-VEG-SHR Symbol 2 Yellow 4 1 ShrubsEN-N-VEG-SHRB-P Hatch Pattern 2 Yellow 4 1 Shrub BedEN-N-VEG-SM1-P Hatch Pattern 3 Green 7 0 Seeding and Mulching Type 1EN-N-VEG-SM2-P Hatch Pattern 6 Magenta 7 0 Seeding and Mulching Type 2EN-N-VEG-SM3-P Hatch Pattern 2 Yellow 7 0 Seeding and Mulching Type 3

app3-environ Page 4 of 4

Page 56: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-4

LAYER STANDARDS

For

FOUNDATION DRAWINGS

Page 57: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:FD - Foundation Design

Status (B): The following abbreviations are used:E - Existing Conditions

Feature (CCC-CC): The feature portion of the layer name is defined by a single component

Annotation (D): The annotation portion is applied at the "feature" level.For example: FD-E-DESC1-T

FOUNDATION DESIGN LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

app4-foundations Page 1 of 2

Page 58: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionFD-E-BASE100-T SYMBOL 130 Cyan 2 0.25 Sheet scale = 100'FD-E-BASE50-T SYMBOL 130 Cyan 2 0.25 Sheet scale = 50'FD-E-CHART_FRAME SYMBOL 7 White 2 0.25 Sheet borderFD-E-CHART_TEXT-TCONTINUOUS 130 Cyan 2 0.25 Sheet textFD-E-CONEPLOT1 SYMBOL 3 Green 2 0.25 Cone graph on p.1FD-E-CONEPLOT2 SYMBOL 3 Green 2 0.25 Cone graph on p.2FD-E-CONEPLOT3 SYMBOL 3 Green 2 0.25 Cone graph on p.3FD-E-CONEPLOT4 SYMBOL 3 Green 2 0.25 Cone graph on p.4FD-E-CONEPLOT5 SYMBOL 3 Green 2 0.25 Cone graph on p.5FD-E-DESC1-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.1FD-E-DESC2-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.2FD-E-DESC3-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.3FD-E-DESC4-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.4FD-E-DESC5-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.5FD-E-ELEVSCAL1 SYMBOL 130 Cyan 2 0.25 Elevation text on p.1FD-E-ELEVSCAL2 SYMBOL 130 Cyan 2 0.25 Elevation text on p.2FD-E-ELEVSCAL3 SYMBOL 130 Cyan 2 0.25 Elevation text on p.3FD-E-ELEVSCAL4 SYMBOL 130 Cyan 2 0.25 Elevation text on p.4FD-E-ELEVSCAL5 SYMBOL 130 Cyan 2 0.25 Elevation text on p.5FD-E-GNDWATER1 SYMBOL 6 Magenta 2 0.25 Ground water on p.1FD-E-GNDWATER2 SYMBOL 6 Magenta 2 0.25 Ground water on p.2FD-E-GNDWATER3 SYMBOL 6 Magenta 2 0.25 Ground water on p.3FD-E-GNDWATER4 SYMBOL 6 Magenta 2 0.25 Ground water on p.4FD-E-GNDWATER5 SYMBOL 6 Magenta 2 0.25 Ground water on p.5FD-E-LOGO SYMBOL 7 White 2 0.25 MTO logoFD-E-SAMPLES1 SYMBOL 2 Yellow 2 0.25 Soil samples on p.1FD-E-SAMPLES2 SYMBOL 2 Yellow 2 0.25 Soil samples on p.2FD-E-SAMPLES3 SYMBOL 2 Yellow 2 0.25 Soil samples on p.3FD-E-SAMPLES4 SYMBOL 2 Yellow 2 0.25 Soil samples on p.4FD-E-SAMPLES5 SYMBOL 2 Yellow 2 0.25 Soil samples on p.5FD-E-VANES1 SYMBOL 2 Yellow 2 0.25 Vanes on p.1FD-E-VANES2 SYMBOL 2 Yellow 2 0.25 Vanes on p.2FD-E-VANES3 SYMBOL 2 Yellow 2 0.25 Vanes on p.3FD-E-VANES4 SYMBOL 2 Yellow 2 0.25 Vanes on p.4FD-E-VANES5 SYMBOL 2 Yellow 2 0.25 Vanes on p.5

app4-foundations Page 2 of 2

Page 59: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-5

LAYER STANDARDS

For

GEOTECHNICAL DRAWINGS

Page 60: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:GE - Geotechnical

Status (B): The following abbreviations are used:N - New Construction

Feature (CCC-CC):The feature portion of the layer name is defined by 3 components. - the 1st portion indentifies a drawing type - the 2nd portion indentifies a feature group - the 3rd portion identifies the feature

The following "drawing type" abbreviations are used:MAP - Drawing Frame and Title Block Info PIT - Pit Sketch TYP - Typical

The following "feature-group" abbreviations are used:

BASE - Base Material SUB - Sub BaseBIN - Binder Courses SUBQ - Sub-surface MaterialsERTH - Earth SURF - Surface MaterialsMISC - Miscellaneous SYM - Symbol

GEOTECHNICAL LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC )

app5-geotech Page 1 of 5

Page 61: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) Description ============== Map Layers ==============GE-N-MAP-SYM-CONT SYMBOL 7 White 6 0.75 Contract numberGE-N-MAP-SYM-NTH SYMBOL 7 White 6 0.75 North arrow symbolGE-N-MAP-SYM-SCE SYMBOL 3 Green 7 0.30 Symbol for source positionGE-N-MAP-SYM-WP SYMBOL 7 White 6 0.75 Work project numberGE-N-MAP-TEXT-GRID CONTINUOUS 6 Magenta 5 0.60 Title grid textGE-N-MAP-TEXT-TLE CONTINUOUS 7 White 6 0.75 Title block text ============== Pit Layers ==============GE-N-PIT-SYM-AUG SYMBOL 1 Red 1 0.20 Symbol for boreholeGE-N-PIT-SYM-BAC SYMBOL 2 Yellow 2 0.25 Test Pit Dug by BackhoeGE-N-PIT-SYM-BED SYMBOL 3 Green 7 0.30 Symbol for bed rockGE-N-PIT-SYM-BLG SYMBOL 1 Red 1 0.20 Symbol for buildingGE-N-PIT-SYM-BUS SYMBOL 3 Green 7 0.30 Symbol for bushGE-N-PIT-SYM-CON SYMBOL 1 Red 1 0.20 Symbol for coniferousGE-N-PIT-SYM-DEC SYMBOL 1 Red 1 0.20 Symbol for deciduousGE-N-PIT-SYM-FAC SYMBOL 1 Red 1 0.20 Symbol for pit faceGE-N-PIT-SYM-FEN SYMBOL 1 Red 1 0.20 Symbol for fence lineGE-N-PIT-SYM-HL SYMBOL 1 Red 1 0.20 Symbol for power lineGE-N-PIT-SYM-HWY SYMBOL 3 Green 3 0.20 Symbol for highwayGE-N-PIT-SYM-MAR SYMBOL 1 Red 1 0.20 Symbol for marshGE-N-PIT-SYM-OUT SYMBOL 1 Red 1 0.20 Symbol for pit outlineGE-N-PIT-SYM-PIP SYMBOL 1 Red 1 0.20 Symbol for pipelineGE-N-PIT-SYM-RIV SYMBOL 4 Cyan 3 0.40 Symbol for riverGE-N-PIT-SYM-RR SYMBOL 1 Red 1 0.20 Symbol for rail roadGE-N-PIT-SYM-SLO SYMBOL 3 Green 7 0.3 Symbol for slopeGE-N-PIT-SYM-STR SYMBOL 1 Red 1 0.20 Symbol for structureGE-N-PIT-SYM-TEL SYMBOL 1 Red 1 0.20 Symbol for telephone lineGE-N-PIT-SYM-TWP SYMBOL 1 Red 1 0.20 Symbol for township rd

app5-geotech Page 2 of 5

Page 62: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionGE-N-PIT-TEXT-GRID CONTINUOUS 6 Magenta 5 0.60 Title grid textGE-N-PIT-TEXT-TLE CONTINUOUS 7 White 6 0.75 Title block text ============== Typical Layers ==============GE-N-TYP-BASE-AT CONTINUOUS 1 Red 1 0.2 Asphalt Treated BaseGE-N-TYP-BASE-CT CONTINUOUS 1 Red 1 0.20 Cement treated baseGE-N-TYP-BASE-GRAN CONTINUOUS 1 Red 1 0.20 Granular "A" BaseGE-N-TYP-BASE-GRO CONTINUOUS 1 Red 1 0.20 Granular "O"GE-N-TYP-BASE-OGD CONTINUOUS 1 Red 1 0.20 Open graded drainage layerGE-N-TYP-BASE-PCC CONTINUOUS 1 Red 1 0.20 Portland Concrete BaseGE-N-TYP-BIN-HDB CONTINUOUS 3 Green 7 0.30 Heavy duty binder courseGE-N-TYP-BIN-HL2 CONTINUOUS 3 Green 7 0.3 HL-2 binder courseGE-N-TYP-BIN-HL3 CONTINUOUS 3 Green 7 0.3 HL-3 binder courseGE-N-TYP-BIN-HL4 CONTINUOUS 3 Green 7 0.3 HL-4 binder courseGE-N-TYP-BIN-HL8 CONTINUOUS 3 Green 7 0.3 HL-8 binder courseGE-N-TYP-BIN-MDB CONTINUOUS 3 Green 7 0.3 Medium Duty Binder CourseGE-N-TYP-BIN-RHM CONTINUOUS 3 Green 7 0.3 Recycled Binder CourseGE-N-TYP-ERTH-CUT CONTINUOUS 1 Red 1 0.2 Earth CutGE-N-TYP-ERTH-FIL CONTINUOUS 1 Red 1 0.2 Earth FillGE-N-TYP-MISC-BT CONTINUOUS 1 Red 1 0.20 Bituthene tapeGE-N-TYP-MISC-CB CONTINUOUS 1 Red 1 0.2 Catch BasinGE-N-TYP-MISC-CG CONTINUOUS 1 Red 1 0.20 Curb and gutterGE-N-TYP-MISC-DB CONTINUOUS 1 Red 1 0.20 Dowel barGE-N-TYP-MISC-GEO CONTINUOUS 1 Red 1 0.20 GeotextileGE-N-TYP-MISC-GR CONTINUOUS 1 Red 1 0.20 Guide railGE-N-TYP-MISC-JT CONTINUOUS 3 Green 7 0.30 JointGE-N-TYP-MISC-LTD CONTINUOUS 1 Red 1 0.20 Load transfer deviceGE-N-TYP-MISC-MH CONTINUOUS 1 Red 1 0.20 ManholeGE-N-TYP-MISC-MIL CONTINUOUS 1 Red 1 0.20 Mill/coldplaneGE-N-TYP-MISC-RIP CONTINUOUS 1 Red 1 0.2 Rip-rapGE-N-TYP-MISC-R&F CONTINUOUS 3 Green 7 0.3 Rout and Fill

app5-geotech Page 3 of 5

Page 63: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionGE-N-TYP-MISC-R&S CONTINUOUS 3 Green 7 0.3 Rout and SealGE-N-TYP-MISC-SEW CONTINUOUS 1 Red 1 0.20 SewerGE-N-TYP-MISC-SOD CONTINUOUS 1 Red 1 0.20 SodGE-N-TYP-MISC-SUB CONTINUOUS 3 Green 7 0.3 Sub DrainGE-N-TYP-MISC-TAC CONTINUOUS 3 Green 7 0.30 Tack coatGE-N-TYP-MISC-TIE CONTINUOUS 1 Red 1 0.20 Tie barGE-N-TYP-MISC-TPS CONTINUOUS 1 Red 1 0.20 TopsoilGE-N-TYP-SUB-CLR CONTINUOUS 1 Red 1 0.20 Clear stoneGE-N-TYP-SUB-GRA CONTINUOUS 1 Red 1 0.20 Granular"A" subbaseGE-N-TYP-SUB-GRB CONTINUOUS 1 Red 1 0.20 Granular"B" subbaseGE-N-TYP-SUB-SSM CONTINUOUS 1 Red 1 0.20 Select subgrade materialGE-N-TYP-SUBQ-ERTH CONTINUOUS 1 Red 1 0.2 Earth SubgradeGE-N-TYP-SUBQ-MUS CONTINUOUS 1 Red 1 0.20 MuskegGE-N-TYP-SUBQ-ORG CONTINUOUS 1 Red 1 0.20 OrganicsGE-N-TYP-SUBQ-RK CONTINUOUS 1 Red 1 0.2 Rock SubgradeGE-N-TYP-SUBQ-RK-CUTCONTINUOUS 1 Red 1 0.2 Rock CutGE-N-TYP-SUBQ-RK-FILLCONTINUOUS 1 Red 1 0.2 Rock FillGE-N-TYP-SUBQ-STR CONTINUOUS 1 Red 1 0.2 Rock ShatterGE-N-TYP-SUBQ-SWP CONTINUOUS 1 Red 1 0.20 SwampGE-N-TYP-SUBQ-WAT CONTINUOUS 4 Cyan 3 0.40 WaterGE-N-TYP-SURF-CIP CONTINUOUS 3 Green 7 0.30 Cold in place resurfacingGE-N-TYP-SURF-DFC CONTINUOUS 3 Green 7 0.30 DFC surface courseGE-N-TYP-SURF-GRA CONTINUOUS 1 Red 1 0.20 Granular "A" surfaceGE-N-TYP-SURF-HIP CONTINUOUS 3 Green 7 0.30 Hot in place resurfacingGE-N-TYP-SURF-HL1 CONTINUOUS 3 Green 7 0.30 HL1 surface courseGE-N-TYP-SURF-HL3 CONTINUOUS 3 Green 7 0.30 HL3 surface courseGE-N-TYP-SURF-HL4 CONTINUOUS 3 Green 7 0.30 HL4 surface courseGE-N-TYP-SURF-MIC CONTINUOUS 3 Green 7 0.30 Micro surfacingGE-N-TYP-SURF-OFC CONTINUOUS 3 Green 7 0.30 OFC surface courseGE-N-TYP-SURF-PCC CONTINUOUS 3 Green 7 0.3 Portland Concrete SurfaceGE-N-TYP-SURF-RHM CONTINUOUS 3 Green 7 0.30 RHM surface courseGE-N-TYP-SURF-ST CONTINUOUS 1 Red 1 0.20 Surface treatment

app5-geotech Page 4 of 5

Page 64: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionGE-N-TYP-TEXT-GRID CONTINUOUS 6 Magenta 5 0.60 Title grid textGE-N-TYP-TEXT-TLE CONTINUOUS 7 White 6 0.75 Title block text

app5-geotech Page 5 of 5

Page 65: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-6

LAYER STANDARDS

For

ONTARIO PROVINCIAL STANDARD DRAWINGS

Page 66: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

The OPS Layer Standards apply a drafting-oriented approach

Discipline (AA): The following abbreviations are used:OPS - Ontario Provincial Standards

Status (B): The following abbreviations are used:S - Standard

Feature (CCC-CC): The feature portion of the layer name defines the drafting specific definition of the layer content

The following abbreviations are used:

L# - Solid Lines CL# - Centre Lines DL# - Dashed Lines

TEXT - Text

NOTE: The drawings from the OPS library published prior to the year 2000 must be converted to comply withIES CAD R2.1 before any further modification (the proper routine is included in the menu).The conversion process may leave some old layers (from the IES CAD R2) because there is a hatchincompatibility between AutoCAD R12 and R13.

P# - Hatch PatternCONS - Construction LineDIM - Dimension

BORDER - Drawing Frame and Title Block Information

PROVINCIAL STANDARDS LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC )

app6-opsd Page 1 of 3

Page 67: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# Color

Pen Thickness

(mm) Description ============== Border Layers ==============DWGINFO CONTINUOUS 7 White No Plot Drawing InformationBORDER CONTINUOUS 6 Magenta 0.75 Border, Frame, Title Block & Logo ============== Line Layers ==============OPS-S-75MM-L CONTINUOUS 6 Magenta 0.75 Entity Line - Broad LineOPS-S-25MM-CL1 OPS-CL1 2 Yellow 0.25 Centre line 1 - 0.25mmOPS-S-25MM-CL2 OPS-CL2 22 Red Shade 0.25 Center line 2 - 0.25mmOPS-S-25MM-CL3 OPS-CL3 92 Green Shade 0.25 User Defined Line - 0.25mm OPS-S-25MM-CL4 OPS-CL4 132 Cyan Shade 0.25 User Defined Line - 0.25mm OPS-S-15MM-CL1 OPS-CL1 13 Red Shade 0.15 Centre line 1 - 0.15mmOPS-S-15MM-CL2 OPS-CL2 13 Red Shade 0.15 Centre line 1 - 0.15mmOPS-S-15MM-CL3 OPS-CL3 13 Red Shade 0.15 User Defined Line - 0.15mm OPS-S-15MM-CL4 OPS-CL4 13 Red Shade 0.15 User Defined Line - 0.15mm OPS-S-25MM-DL1 OPS-DL1 92 Green Shade 0.25 Dashed Line - 0.25mmOPS-S-25MM-DL2 OPS-DL2 132 Cyan Shade 0.25 Dashed Line - 0.25mmOPS-S-15MM-DL1 OPS-DL1 13 Red Shade 0.15 Dashed Line - 0.15mmOPS-S-15MM-DL2 OPS-DL1 13 Red Shade 0.15 Dashed Line - 0.15mmOPS-S-40MM-DL3 OPS-DL3 63 Light Yellow 0.40 Dashed Line - 0.40mmOPS-S-40MM-DL4 OPS-DL4 183 Blue shade 0.40 Dashed Line - 0.40mmOPS-S-25MM-DL5 OPS-DL5 92 Green Shade 0.25 User Defined Line - 0.25mm OPS-S-25MM-DL6 OPS-DL6 132 Cyan Shade 0.25 User Defined Line - 0.25mm OPS-S-40MM-DL7 OPS-DL7 63 Light Yellow 0.40 User Defined Line - 0.40mmOPS-S-40MM-DL8 OPS-DL8 183 Blue shade 0.40 User Defined Line - 0.40mmOPS-S-50MM-DL9 OPS-DL9 4 Cyan 0.50 User Defined Line - 0.50mmOPS-S-25MM-L1 CONTINUOUS 22 Red Shade 0.25 Entity Line - 0.25mmOPS-S-15MM-L1 CONTINUOUS 13 Red Shade 0.15 Entity Line - 0.15mmOPS-S-25MM-L2 CONTINUOUS 92 Green Shade 0.25 Entity Line - 0.25mmOPS-S-15MM-L2 CONTINUOUS 13 Red Shade 0.15 Entity Line - 0.15mmOPS-S-40MM-L1 CONTINUOUS 63 Light Yellow 0.40 Entity Line - 0.40mmOPS-S-40MM-L2 CONTINUOUS 183 Blue shade 0.40 Entity Line - 0.40mm

app6-opsd Page 2 of 3

Page 68: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# Color

Pen Thickness

(mm) DescriptionOPS-S-50MM-L CONTINUOUS 4 Cyan 0.50 Entity Line - 0.50mm ============== Hatch Layers ==============OPS-S-25MM-P1 CONTINUOUS 22 Red Shade 0.25 Hatch Pattern - 0.25mmOPS-S-25MM-P2 CONTINUOUS 92 Green Shade 0.25 Hatch Pattern - 0.25mm OPS-S-25MM-P3 CONTINUOUS 132 Cyan Shade 0.25 Hatch Pattern - 0.25mm OPS-S-25MM-P4 CONTINUOUS 2 Yellow 0.25 Hatch Pattern - 0.25mm OPS-S-15MM-P1 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mmOPS-S-15MM-P2 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm OPS-S-15MM-P3 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm OPS-S-15MM-P4 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm OPS-S-40MM-P1 CONTINUOUS 63 Light Yellow 0.40 Hatch Pattern - 0.40mmOPS-S-40MM-P2 CONTINUOUS 183 Blue shade 0.40 Hatch Pattern - 0.40mmOPS-S-40MM-P3 CONTINUOUS 3 Green 0.40 Hatch Pattern - 0.40mmOPS-S-50MM-P1 CONTINUOUS 4 Cyan 0.50 Hatch Pattern - 0.50mmOPS-S-50MM-P2 CONTINUOUS 214 Purple 0.50 Hatch Pattern - 0.50mm ============== Dimension Layer ==============OPS-S-DIM CONTINUOUS 132 Cyan Shade 0.25 Dimension Line OPS-S-DIM15 CONTINUOUS 13 Red Shade 0.15 Dimension Line ==============Text Layer ==============OPS-S-TEXT CONTINUOUS 7 White varies Varies size: see Chapter 5.1 ==============Temporary Work Layer ==============OPS-S-CONS CONTINUOUS 8 Grey No Plot Construction (working) line

app6-opsd Page 3 of 3

Page 69: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-7

LAYER STANDARDS

For

PLANNING & DESIGN DRAWINGS

Page 70: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:MT - MTO commonPD - Planning & Design

Status (B): The following abbreviations are used:G - General (non-feature specific)N - New Construction (Plan)R - Removals ( Plan)P - ProfileT - Typical Sections (NOTE - a "drafting-oriented" layering approach

is defined for Typical Sections)

Feature (CCC-CC): The feature portion of the layer name is defined by 2 components. - the 1st portion indentifies a feature group - the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:ALI - Alignments MSC - MiscellaneousBAR - Barriers PMK - Pavement MarkingsBED - Road Bed RDS - RoadwaysDRN - Drainage ROW - Right of WayGND - Ground VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature-group" level.For example: PD-N-BAR-T

PLANNING & DESIGN LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

app7-design Page 1 of 8

Page 71: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== General Layers ==============BORDER CONTINUOUS 6 Magenta 135 0.75 Frame - Title Block BordersDWGINFO CONTINUOUS 7 White 9 No Plot Drawing Specific Information VPORTS CONTINUOUS 4 Cyan 8 No Plot View Port - Paper Space Limits MT-G-GRID CONTINUOUS 171 Blue 251 0.20 GridMT-G-GRID-T TEXT 171 Blue 251 0.20 Grid TextMT-P-GRID CONTINUOUS 251 Grey 251 0.20 Profile GridMT-P-GRID-T TEXT 254 Grey 254 0.25 Profile Grid TextPD-G-CONS CONTINUOUS 1 Red 251 No Plot Temporary Construction LinesPD-G-DIM CONTINUOUS 2 Yellow 254 0.25 Dimensions PD-G-LEGEND CONTINUOUS 50 Yellow 9 0.30 Keyplan - LegendPD-G-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm LinesPD-G-40MM CONTINUOUS 3 Green 253 0.40 0.40mm Lines PD-G-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm Lines PD-G-75MM CONTINUOUS 6 Magenta 135 0.75 0.75mm Lines PD-G-TEXT TEXT 2 Yellow 254 0.25 General TextPD-N-LIMIT CONTINUOUS 7 White 9 0.30 Contract - Construction Limits ============== Alignment Layers ==============PD-N-ALI-CL CONTINUOUS 20 Red 9 0.30 Centerline AlignmentPD-N-ALI-CL-T TEXT 32 Orange 254 0.25 Centerline Alignment TextPD-N-ALI-CL-PTS CONTINUOUS 7 White 9 0.30 Centerline Alignment Points ============== Barrier Layers ==============PD-N-BAR-FL FENCE 52 Yellow 254 0.25 FencePD-N-BAR-GU3 GUIDERAIL 190 Magenta 9 0.30 Guide Rail (3 Cable)PD-N-BAR-GU6 GUIDERAIL 190 Magenta 9 0.30 Guide Rail (6 Cable)PD-N-BAR-GUB GUIDERAIL 190 Magenta 9 0.30 Guide Rail (Box Beam)PD-N-BAR-GUC GUIDERAIL 190 Magenta 9 0.30 Guide Rail (Concrete Barrier)PD-N-BAR-GUI GUIDERAIL 190 Magenta 9 0.30 Guide Rail (IBC)

app7-design Page 2 of 8

Page 72: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionPD-N-BAR-GUS GUIDERAIL 190 Magenta 9 0.30 Guide Rail (Steel Beam)PD-N-BAR-IBM SYMBOL 192 Magenta 254 0.25 Inertial Barrier Modules (IBM)PD-N-BAR-JB CONTINUOUS 130 Cyan 9 0.30 Jersey BarrierPD-N-BAR-NB CONTINUOUS 240 Red 9 0.30 Noise BarrierPD-N-BAR-T TEXT 2 Yellow 254 0.25 Barrier Text ============== Drainage Layers ==============PD-N-DRN-BD R-O-W 50 Yellow 9 0.30 Bottom Of DitchPD-N-DRN-CB SYMBOL 142 Cyan 254 0.25 Catch BasinPD-N-DRN-CV CONTINUOUS 140 Cyan 9 0.30 CulvertPD-N-DRN-DI SYMBOL 142 Cyan 254 0.25 Ditch InletPD-N-DRN-MH SYMBOL 192 Magenta 254 0.25 ManholePD-N-DRN-RR CONTINUOUS 142 Cyan 254 0.25 Rip-RapPD-N-DRN-SAN R-O-W 130 Cyan 9 0.30 Sanitary Sewer PipePD-N-DRN-SEW SUBGRADE 4 Cyan 8 0.50 Storm Sewer PipePD-N-DRN-SUB SUBGRADE 130 Cyan 9 0.30 Sub DrainPD-N-DRN-WL CONTINUOUS 162 Blue 254 0.25 Water LevelPD-N-DRN-T TEXT 2 Yellow 254 0.25 Drainage Text ============== Miscellaneous Layers ==============PD-N-MSC CONTINUOUS 150 Cyan 9 0.30 Miscellaneous (generic items)PD-N-MSC-AS CONTINUOUS 92 Green 254 0.25 Asphalt (Miscellaneous Paving)PD-N-MSC-BN SYMBOL 32 Orange 254 0.25 Bull NosePD-N-MSC-CO CONTINUOUS 22 Red 254 0.25 Concrete PD-N-MSC-COA CONTINUOUS 92 Green 254 0.25 Concrete with Asphalt SurfacePD-N-MSC-EJ CONTINUOUS 192 Magenta 254 0.25 Expansion JointPD-N-MSC-GAB CONTINUOUS 130 Cyan 9 0.30 Gabion BasketsPD-N-MSC-RW CONTINUOUS 22 Red 254 0.25 Retaining WallPD-N-MSC-SIGN CONTINUOUS 22 Red 254 0.25 Sign Footing PD-N-MSC-SWA CONTINUOUS 192 Magenta 254 0.25 Sidewalk (Asphalt)PD-N-MSC-SWC CONTINUOUS 192 Magenta 254 0.25 Sidewalk (Concrete)PD-N-MSC-T TEXT 2 Yellow 254 0.25 Miscellaneous Text

app7-design Page 3 of 8

Page 73: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Pavement Marking Layers ==============PD-N-PMK CONTINUOUS 50 Yellow 9 0.30 Pavement MarkingsPD-N-PMK-GORE CONTINUOUS 40 Orange 9 0.30 Gore AreaPD-N-PMK-PMBW DASHED 7 White 9 0.30 Broken White LinePD-N-PMK-PMBY DASHED 50 Yellow 9 0.30 Broken Yellow LinePD-N-PMK-PMSW CONTINUOUS 7 White 9 0.30 Solid White LinePD-N-PMK-PMSY CONTINUOUS 50 Yellow 9 0.30 Solid Yellow LinePD-N-PMK-T TEXT 2 Yellow 254 0.25 Pavement Marking Text ============== Roadway Layers ==============PD-N-RDS-CGA CONTINUOUS 25 Red 252 0.60 Curb and Gutter (Asphalt)PD-N-RDS-CGC CONTINUOUS 25 Red 252 0.60 Curb and Gutter (Concrete)PD-N-RDS-EP CONTINUOUS 50 Yellow 9 0.30 Edge of PavementPD-N-RDS-EPS CONTINUOUS 90 Green 9 0.30 Paved ShoulderPD-N-RDS-ES CONTINUOUS 43 Orange 253 0.40 Granular ShoulderPD-N-RDS-TC CONTINUOUS 90 Green 9 0.30 Top of CutPD-N-RDS-TS SHORTDASH 160 Blue 9 0.30 Toe of Fill SlopePD-N-RDS-UR GR-ROAD 50 Yellow 9 0.30 Unpaved RoadPD-N-RDS-T TEXT 2 Yellow 254 0.25 Road Text ============== Property and Right of Way Layers ==============PD-N-ROW-PLI ROW-PLI 210 Magenta 134 1.00 Limited Interest ( Permanent)PD-N-ROW-TLI ROW-TLI 40 Orange 134 1.00 Limited Interest (Temporary)PD-N-ROW-PRI ROW-PRI 20 Red 134 1.00 Property Required (Intermediate)PD-N-ROW-PRU ROW-PRU 50 Yellow 134 1.00 Property Required (Ultimate)PD-N-ROW-DEL CONTINUOUS 20 Red 9 0.30 Property DeletionPD-N-ROW-T TEXT 2 Yellow 254 0.25 Property and ROW Text ============== Vegetation Layers ==============

app7-design Page 4 of 8

Page 74: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionPD-N-VEG-SOD CONTINUOUS 82 Green 254 0.25 SodPD-N-VEG-WO BUSH 102 Green 254 0.25 Wood OutlinePD-N-VEG-T TEXT 2 Yellow 254 0.25 Vegetation Text ============== General Profile Layers ==============PD-P-LIMIT CONTINUOUS 7 White 9 0.30 Contract - Construction LimitsPD-P-LIMIT-T TEXT 192 Magenta 254 0.40 Job Limits Text ============== Road Bed Profile Layers ==============PD-P-BED-GRA CONTINUOUS 163 Blue 253 0.40 Top of Granular 'A'PD-P-BED-GRB CONTINUOUS 3 Green 253 0.40 Top of Granular 'B'PD-P-BED-SG SUBGRADE 43 Orange 253 0.40 SubgradePD-P-BED-TCL CUTLT 33 Red 253 0.40 Top of Cut - LeftPD-P-BED-TCR CUTRT 93 Green 253 0.40 Top of Cut - RightPD-P-BED-TF CONTINUOUS 143 Cyan 253 0.40 Top of Filter CoursePD-P-BED-TP CONTINUOUS 216 Magenta 135 0.75 Top of PavementPD-P-BED-TSL SLOPELT 63 Yellow 253 0.40 Toe of Fill Slope - LeftPD-P-BED-TSR SLOPERT 153 Cyan 253 0.40 Toe of Fill Slope - RightPD-P-BED-VALBL TEXT 63 Yellow 253 0.40 Vert. Align. Stations - TablesPD-P-BED-VAPTS CONTINUOUS 54 Yellow 8 0.50 Vert. Align. VPI - TangentsPD-P-BED-T TEXT 2 Yellow 254 0.25 Profile RoadBed Text

app7-design Page 5 of 8

Page 75: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Drainage Profile Layers ==============PD-P-DRN-BDL DITCHLT 143 Cyan 253 0.40 Bottom Of Ditch - LeftPD-P-DRN-BDM DITCHM 193 Magenta 253 0.40 Bottom Of Ditch - MedianPD-P-DRN-BDR DITCHRT 3 Green 253 0.40 Bottom Of Ditch - RightPD-P-DRN-CB SYMBOL 33 Red 253 0.40 Catch BasinPD-P-DRN-CV SYMBOL 193 Magenta 253 0.40 CulvertPD-P-DRN-MH SYMBOL 33 Red 253 0.40 ManholePD-P-DRN-SAN CONTINUOUS 3 Green 253 0.40 Sanitary Sewer PipePD-P-DRN-SEW CONTINUOUS 3 Green 253 0.40 Storm Sewer PipePD-P-DRN-SUB CONTINUOUS 143 Cyan 253 0.40 Sub DrainPD-P-DRN-T TEXT 2 Yellow 254 0.25 Profile Drainage Text ============== Ground Profile Layers ==============PD-P-GND-MUB MUSKEG 163 Blue 253 0.40 Bottom Of MuskegPD-P-GND-MUT MUSKEG 193 Magenta 253 0.40 Top Of MuskegPD-P-GND-OG CONTINUOUS 3 Green 253 0.40 Original GroundPD-P-GND-RK ROCK 33 Red 253 0.40 Top of RockPD-P-GND-T TEXT 2 Yellow 254 0.25 Profile Ground Text ============== Miscellaneous Profile Layers ==============PD-P-MSC CONTINUOUS 63 Yellow 253 0.40 Miscellaneous (generic lines)PD-P-MSC-EF CONTINUOUS 43 Orange 253 0.40 Earth FillPD-P-MSC-EX EARTH 43 Orange 253 0.40 Bottom of Earth (or Rock) ExcavationPD-P-MSC-RF CONTINUOUS 33 Red 253 0.40 Rock FillPD-P-MSC-SH DASHED 33 Red 253 0.40 ShatterPD-P-MSC-T TEXT 2 Yellow 254 0.25 Profile Miscellaneous Text

app7-design Page 6 of 8

Page 76: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Removal Layers ==============PD-R-BAR-FL FENCE 152 Cyan 254 0.25 FencePD-R-BAR-GU GUIDERAIL 150 Cyan 9 0.30 Guide RailPD-R-BAR-T TEXT 2 Yellow 254 0.25 Removal Barrier TextPD-R-DRN-CB SYMBOL 152 Cyan 254 0.25 Catch BasinPD-R-DRN-CV CONTINUOUS 150 Cyan 9 0.30 CulvertPD-R-DRN-MH SYMBOL 152 Cyan 254 0.25 ManholePD-R-DRN-SAN R-O-W 150 Cyan 8 0.50 Sanitary Sewer PipePD-R-DRN-SEW SUBGRADE 154 Cyan 9 0.30 Storm Sewer PipePD-R-DRN-SUB SUBGRADE 150 Cyan 8 0.50 Sub DrainPD-R-DRN-T TEXT 2 Yellow 254 0.25 Removal Drainage TextPD-R-MSC CONTINUOUS 150 Cyan 9 0.30 Miscellaneous (generic items)PD-R-MSC-AS CONTINUOUS 150 Cyan 9 0.30 Asphalt PavementPD-R-MSC-CO CONTINUOUS 150 Cyan 9 0.30 Concrete PavementPD-R-MSC-COA CONTINUOUS 150 Cyan 9 0.30 Concrete with Asphalt SurfacePD-R-MSC-SWA CONTINUOUS 152 Cyan 254 0.25 Sidewalk (Asphalt)PD-R-MSC-SWC CONTINUOUS 152 Cyan 254 0.25 Sidewalk (Concrete)PD-R-MSC-T TEXT 2 Yellow 254 0.25 Removal Miscellaneous TextPD-R-RDS-CGA CONTINUOUS 175 Blue 252 0.60 Curb and Gutter (Asphalt)PD-R-RDS-CGC CONTINUOUS 175 Blue 252 0.60 Curb and Gutter (Concrete)PD-R-RDS-UR GR-ROAD 150 Cyan 9 0.30 Edge of Unpaved RoadPD-R-RDS-T TEXT 2 Yellow 254 0.25 Removal Road TextPD-R-VEG-CLR CONTINUOUS 150 Cyan 9 0.30 ClearedPD-R-VEG-CLRCUT CONTINUOUS 152 Cyan 254 0.25 Close Cut ClearedPD-R-VEG-CLRGRB CONTINUOUS 150 Cyan 9 0.30 Cleared & GrubbedPD-R-VEG-GRB CONTINUOUS 152 Cyan 254 0.25 GrubbedPD-R-VEG-T TEXT 2 Yellow 254 0.25 Removal Vegetation Text

app7-design Page 7 of 8

Page 77: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Typical Section Layers ==============PD-T-25MM CONTINUOUS 132 Cyan 254 0.25 0.25mm LinePD-T-25MM-P CONTINUOUS 132 Cyan 254 0.25 0.25mm HatchPD-T-30MM CONTINUOUS 7 White 9 0.30 0.30mm LinePD-T-30MM-P CONTINUOUS 7 White 9 0.30 0.30mm HatchPD-T-40MM CONTINUOUS 33 Red 253 0.40 0.40mm LinePD-T-40MM-DASH DASHED 33 Red 253 0.40 0.40mm Dashed LinePD-T-50MM CONTINUOUS 24 Red 8 0.50 0.50mm LinePD-T-50MM-P CONTINUOUS 24 Red 8 0.50 0.50mm HatchPD-T-75MM CONTINUOUS 6 Magenta 135 0.75 0.75mm LinePD-T-CL CENTER 22 Red 254 0.25 CenterlinePD-T-DIM CONTINUOUS 132 Cyan 254 0.25 DimensionsPD-T-OG MEDDASH 90 Green 9 0.30 Original GroundPD-T-NOTE-T TEXT 91 Green 251 0.20 General NotesPD-T-TEXT TEXT 91 Green 251 0.20 All Text for Typicals

app7-design Page 8 of 8

Page 78: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-8

LAYER STANDARDS

For

PHOTOGRAMMETRY DRAWINGS

Page 79: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:MT - MTO commonPH - Photogrammetry

Status (B): The following abbreviations are used:G - General (non-feature specific)E - Existing Plan

Feature (CCC-CC): The feature portion of the layer name is defined by 2 components. - the 1st portion indentifies a feature group - the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:ALI - Alignments MON - Survey Monuments & ControlBAR - Barriers MSC - MiscellaneousCTR - Contours RDS - RoadwaysDRN - Drainage UTL - UtilitiesGND - Ground VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature-group" level.For example: PH-E-BAR-T

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ==============

PHOTOGRAMMETRY LAYER DEFINITIONS- January 2000 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

app8-photog Page 1 of 6

Page 80: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description General Layers ==============BORDER CONTINUOUS 6 Magenta 135 0.75 BordersDWGINFO CONTINUOUS 7 White 9 No Plot Drawing InfoVPORTS CONTINUOUS 4 Cyan 8 No Plot View PortMT-G-GRID CONTINUOUS 171 Blue 251 0.20 GridMT-G-GRID-T TEXT20 171 Blue 251 0.20 Grid TextMT-P-GRID CONTINUOUS 251 Grey 251 0.20 Profile GridMT-P-GRID-T TEXT20 252 Grey 254 0.25 Profile Grid TextPH-G-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm LinePH-G-40MM CONTINUOUS 3 Green 253 0.40 0.40mm LinePH-G-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm LinePH-G-75MM CONTINUOUS 6 Magenta 135 0.75 0.75mm LinePH-G-TEXT TEXT 2 Yellow 254 0.25 General TextPH-E-SCANNED CONTINUOUS 21 Red 251 0.20 Scanned ImagePH-G-SYMBOLS SYMBOL 2 Yellow 254 0.25 SymbolsPH-E-LABELS TEXT20 1 Red 251 No Plot String Labels ==============Alignment Layers ==============PH-E-ALI-E1 CONTINUOUS 20 Red 9 0.30 Entrance Alignment ============== Barrier Layers ==============PH-E-BAR-BB CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Bottom)PH-E-BAR-BT CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Top)PH-E-BAR-FL FENCE 90 Green 9 0.30 Fence (Top)PH-E-BAR-GAT CONTINUOUS 90 Green 9 0.30 GatePH-E-BAR-GU GUIDERAIL 140 Cyan 9 0.30 Guide Rail (Plan Only)PH-E-BAR-NB CONTINUOUS 210 Magenta 9 0.30 Noise Barrier (Top)PH-E-BAR-T TEXT25 2 Yellow 254 0.25 Barrier Text ============== Contour Layers ==============

app8-photog Page 2 of 6

Page 81: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionPH-E-CTR-C1 CONTINUOUS 54 Yellow 8 0.50 Contours (Primary)PH-E-CTR-C2 CONTINUOUS 20 Red 9 0.30 Contours (Secondary)PH-E-CTR-T TEXT25 2 Yellow 254 0.25 Contour Text ============== Drainage Layers ==============PH-E-DRN-BD R-O-W 150 Cyan 9 0.30 Bottom Of DitchPH-E-DRN-CB SYMBOL 170 Blue 9 0.30 Catch BasinPH-E-DRN-CVP SYMBOL 150 Cyan 9 0.30 Culvert (One End)PH-E-DRN-CV-P CONTINUOUS 150 Cyan 9 0.30 Culvert OutlinePH-E-DRN-CVT CONTINUOUS 150 Cyan 9 0.30 Culvert Centreline (Top)PH-E-DRN-DI SYMBOL 170 Blue 9 0.30 Ditch InletPH-E-DRN-EM SHORTDASH 110 Green 9 0.30 Edge of MuskegPH-E-DRN-EM-P CONTINUOUS 110 Green 9 0.30 Muskeg PatternPH-E-DRN-EW CONTINUOUS 154 Cyan 8 0.50 Edge of WaterPH-E-DRN-MH SYMBOL 170 Blue 9 0.30 Manhole San. or SewerPH-E-DRN-RR GR-DRIVE 70 Yellow/Green 9 0.30 Rip-RapPH-E-DRN-T TEXT25 2 Yellow 254 0.25 Drainage Text ============== Ground Feature Layers ==============PH-E-GND-AO CONTINUOUS 50 Yellow 9 0.30 Asphalt OutlinePH-E-GND-AS CONTINUOUS 40 Orange 9 0.30 Asphalt ShotsPH-E-GND-BA CONTINUOUS 140 Cyan 9 0.30 Bank of River or StreamPH-E-GND-BC GR-DRIVE 100 Green 9 0.30 Bottom of Rock CutPH-E-GND-CO CONTINUOUS 180 Blue 9 0.30 Concrete Outline PH-E-GND-CS CONTINUOUS 150 Cyan 9 0.30 Concrete Shots PH-E-GND-EC LONGDASH 20 Red 9 0.30 Entrance CenterlinePH-E-GND-GO GR-DRIVE 40 Orange 9 0.30 Gravel OutlinePH-E-GND-GS CONTINUOUS 40 Orange 9 0.30 Gravel ShotsPH-E-GND-GX CONTINUOUS 40 Orange 9 0.30 Original Ground (Approximate)PH-E-GND-OG CONTINUOUS 210 Magenta 9 0.30 Original Ground FaultPH-E-GND-PG SYMBOL 210 Magenta 9 0.30 Original Ground PointPH-E-GND-RBE SHORTDASH 40 Orange 9 0.30 Railway Ballast Edge

app8-photog Page 3 of 6

Page 82: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionPH-E-GND-RBT CONTINUOUS 40 Orange 9 0.30 Railway Ballast TopPH-E-GND-RKO CONTINUOUS 50 Yellow 9 0.30 Rock OutlinePH-E-GND-RKS CONTINUOUS 50 Yellow 9 0.30 Rock ShotsPH-E-GND-SP GR-DRIVE 40 Orange 9 0.30 Stock Piles - Gravel PitsPH-E-GND-TC CONTINUOUS 100 Green 9 0.30 Top of Rock CutPH-E-GND-XX CONTINUOUS 200 Magenta 9 0.30 Original Ground (Estimated)PH-E-GND-P CONTINUOUS 110 Green 9 0.30 Ground Patterning (ie. Cut - Fill)PH-E-GND-T TEXT25 2 Yellow 254 0.25 Ground Feature Text ============== Miscellaneous Layers ==============PH-E-MSC-AX CONTINUOUS 9 Grey 9 0.30 Excluded AreaPH-E-MSC-AX-P CONTINUOUS 9 Grey 9 0.30 Excluded Area PatternPH-E-MSC-BLF SHORTDASH 230 Red 9 0.30 Building Foundations - RuinsPH-E-MSC-BLR CONTINUOUS 230 Red 9 0.30 Building Roofline RectangularPH-E-MSC-BLR CONTINUOUS 230 Red 9 0.30 Building Roofline CircularPH-E-MSC-BS CONTINUOUS 120 Green 9 0.30 Building SurroundPH-E-MSC-BY CONTINUOUS 7 White 9 0.30 Segment BoundaryPH-E-MSC-CE CONTINUOUS 180 Blue 9 0.30 Cemetery PH-E-MSC-DK CONTINUOUS 40 Orange 9 0.30 Wooden Decks or DocksPH-E-MSC-EJ CONTINUOUS 210 Magenta 9 0.30 Expansion JointPH-E-MSC-EV-Z SYMBOL 80 Yellow/Green 9 0.30 Miscellaneous ElevationPH-E-MSC-GAB CONTINUOUS 70 Yellow/Green 9 0.30 Gabion BasketsPH-E-MSC-GC CONTINUOUS 70 Yellow/Green 9 0.30 Golf CoursePH-E-MSC-HR CONTINUOUS 60 Yellow 9 0.30 Bridge Hand RailsPH-E-MSC-OR CONTINUOUS 180 Blue 9 0.30 OrchardPH-E-MSC-OS CONTINUOUS 130 Cyan 9 0.30 Overhead SignPH-E-MSC-RLT CONTINUOUS 20 Red 9 0.30 Railway - Top of RailPH-E-MSC-RW CONTINUOUS 70 Yellow/Green 9 0.30 Retaining Wall - TopPH-E-MSC-SW CONTINUOUS 20 Red 9 0.30 Sidewalk PH-E-MSC-VI CONTINUOUS 180 Blue 9 0.30 VineyardPH-E-MSC-WW SHORTDASH 40 Orange 9 0.30 Walkways - Trails - PathsPH-E-MSC-T TEXT25 2 Yellow 254 0.25 Miscellaneous Text ==============

app8-photog Page 4 of 6

Page 83: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description Roadway Layers ==============PH-E-RDS-AE CONTINUOUS 50 Yellow 9 0.30 Asphalt EdgesPH-E-RDS-BRD CONTINUOUS 230 Red 9 0.30 Bridge DeckPH-E-RDS-CR CONTINUOUS 130 Cyan 9 0.30 Crown of RoadPH-E-RDS-CU CONTINUOUS 70 Yellow/Green 9 0.30 CurbsPH-E-RDS-DL DASHED 130 Cyan 9 0.30 Driving Lane - EdgePH-E-RDS-EG CONTINUOUS 240 Red 9 0.30 Edge Of GutterPH-E-RDS-EN SHORTDASH 50 Yellow 9 0.30 Entrance - Uncertain SurfacePH-E-RDS-EP CONTINUOUS 63 Yellow 253 0.40 Edge Of PavementPH-E-RDS-ER CONTINUOUS 50 Yellow 9 0.30 Edge Of RampPH-E-RDS-ES GR-DRIVE 40 Orange 9 0.30 Edge Of ShoulderPH-E-RDS-NG GR-DRIVE 40 Orange 9 0.30 Entrance - GravelPH-E-RDS-NP CONTINUOUS 50 Yellow 9 0.30 Entrance - PavedPH-E-RDS-RD CONTINUOUS 210 Magenta 9 0.30 Roads - Uncertain MaterialPH-E-RDS-UR GR-ROAD 40 Orange 9 0.30 Gravel SideroadsPH-E-RDS-T TEXT25 2 Yellow 254 0.25 Roadway Text ============== Survey Monument Layers ==============PH-E-MON SYMBOL 20 Red 9 0.30 Horizontal ControlPH-E-MON-BM SYMBOL 20 Red 9 0.30 Vertical Control

app8-photog Page 5 of 6

Page 84: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Utility Layers ==============PH-E-UTL-AN SYMBOL 210 Magenta 9 0.30 Anchor for Guy WirePH-E-UTL-BH SYMBOL 7 White 9 0.30 Bell - Hydro PolePH-E-UTL-BP SYMBOL 7 White 9 0.30 Bell PolePH-E-UTL-FH SYMBOL 7 White 9 0.30 Fire HydrantPH-E-UTL-HP SYMBOL 7 White 9 0.30 Hydro PolePH-E-UTL-HT CONTINUOUS 7 White 9 0.30 Hydro TowerPH-E-UTL-LS SYMBOL 7 White 9 0.30 Light StandardPH-E-UTL-PW SYMBOL 50 Yellow 9 0.30 Pole WellPH-E-UTL-PO SYMBOL 7 White 9 0.30 Pole - otherPH-E-UTL-WE SYMBOL 140 Cyan 9 0.30 WellPH-E-UTL-T TEXT25 2 Yellow 254 0.25 Utilities Text ============== Vegetation Layers ==============PH-E-VEG-HE HEDGE 100 Green 9 0.30 HedgePH-E-VEG-TR SYMBOL 90 Green 9 0.30 TreesPH-E-VEG-WD BUSH 90 Green 9 0.30 Woods DetailPH-E-VEG-WO CONTINUOUS 90 White 9 0.30 Woods Overhang (Top)PH-E-VEG-T TEXT25 2 Yellow 254 0.25 Vegetation Text

app8-photog Page 6 of 6

Page 85: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-9

LAYER STANDARDS

For

SURVEYS & PLANS DRAWINGS

Page 86: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:MT - MTO commonSP - Surveys & Plans

Status (B): The following abbreviations are used:G - General (non-feature specific)E - Existing PlanL - Legal SurveyP - ProfileQ - Quality Assurance

Feature (CCC-CC):The feature portion of the layer name is defined by 2 components. - the 1st portion indentifies a feature group - the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:ALI - Alignments MON - Survey Monuments & ControlBAR - Barriers MSC - MiscellaneousBDY - Property Boundaries RDS - RoadwaysCTR - Contours ROW - Right of WayDRN - Drainage UTL - UtilitiesGND - Ground VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature-group" level.For example: SP-E-BAR-T

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description

SURVEYS & PLANS LAYER DEFINITIONS

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

- January 2004 -

app9-surveys Page 1 of 9

Page 87: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== General Layers ==============BORDER CONTINUOUS 6 Magenta 135 0.75 BordersDWGINFO CONTINUOUS 7 White 9 No Plot Drawing InfoVPORTS CONTINUOUS 4 Cyan 8 No Plot View PortMT-G-GRID CONTINUOUS 171 Blue 251 0.20 GridMT-G-GRID-T TEXT20 171 Blue 251 0.20 Grid TextMT-P-GRID CONTINUOUS 251 Grey 251 0.20 Profile GridMT-P-GRID-T TEXT20 252 Grey 254 0.25 Profile Grid TextSP-G-CONS CONTINUOUS 7 White 9 No Plot Construction LinesSP-G-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm LineSP-G-40MM CONTINUOUS 3 Green 253 0.40 0.40mm LineSP-G-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm LineSP-G-75MM CONTINUOUS 6 Magenta 9 0.75 0.75mm LineSP-G-TEXT TEXT 2 Yellow 254 0.25 General TextSP-G-SYMBOLS SYMBOL 2 Yellow 254 0.25 SymbolsSP-E-LABELS TEXT20 1 Red 251 No Plot String LabelsSP-E-SCANNED CONTINUOUS 21 Red 251 0.20 Scanned Image ============== Alignment Layers ==============SP-E-ALI CONTINUOUS 40 Orange 9 0.30 Misc AlignmentSP-E-ALI-CL CONTINUOUS 20 Red 9 0.30 Centerline AlignmentSP-E-ALI-CL-C TEXT25 92 Green 254 0.25 Centerline Alignment ChainageSP-E-ALI-CL-PTS SYMBOL 50 Yellow 254 0.30 Centerline Alignment PointsSP-E-ALI-CL-T TEXT25 92 Green 254 0.25 Centreline Alignment TextSP-E-ALI-D1 CONTINUOUS 150 Cyan 9 0.30 Drainage AlignmentSP-E-ALI-E1 CONTINUOUS 20 Red 9 0.30 Entrance AlignmentSP-E-ALI-R1 CONTINUOUS 20 Red 9 0.30 Align Revision - RampSP-E-ALI-S1 CONTINUOUS 20 Red 9 0.30 Sideroad Alignment

app9-surveys Page 2 of 9

Page 88: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Barrier Layers ==============SP-E-BAR-BB CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Bottom)SP-E-BAR-BT CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Top)SP-E-BAR-FB CONTINUOUS 90 Green 9 0.30 Fitch BarrierSP-E-BAR-FL FENCE 90 Green 9 0.30 Fence Line (Ground)SP-E-BAR-GAT CONTINUOUS 90 Green 9 0.30 GateSP-E-BAR-GP-Z SYMBOL 140 Cyan 9 0.30 Guide Rail (Top of Post)SP-E-BAR-GU GUIDERAIL 140 Cyan 9 0.30 Guide Rail (Ground)SP-E-BAR-GW-Z SYMBOL 7 White 9 0.30 Guide Rail (Top of Wire)SP-E-BAR-NB CONTINUOUS 210 Magenta 9 0.30 Noise Barrier (Ground)SP-E-BAR-T TEXT25 2 Yellow 254 0.25 Barrier Text ============== Contour Layers ==============SP-E-CTR-C1 CONTINUOUS 54 Yellow 8 0.50 Contours (Primary)SP-E-CTR-C2 CONTINUOUS 20 Red 9 0.30 Contours (Secondary)SP-E-CTR-T TEXT25 2 Yellow 254 0.25 Contour Text ============== Drainage Layers ==============SP-E-DRN-BD R-O-W 150 Cyan 9 0.30 Bottom Of DitchSP-E-DRN-CB SYMBOL 170 Blue 9 0.30 Catch BasinSP-E-DRN-CVP SYMBOL 220 Magenta 9 0.30 Culvert (One End)SP-E-DRN-CV-P CONTINUOUS 150 Cyan 9 0.30 Culvert SymbologySP-E-DRN-CVT CONTINUOUS 150 Cyan 9 0.30 Culvert Centreline (Top)SP-E-DRN-CV-Z SYMBOL 150 Cyan 9 0.30 Culvert ElevationSP-E-DRN-DB-Z SYMBOL 50 Yellow 9 0.30 Ditch Inlet (Bottom Elevation) SP-E-DRN-DC CONTINUOUS 170 Blue 9 0.30 Ditch CenterlineSP-E-DRN-DI SYMBOL 170 Blue 9 0.30 Ditch InletSP-E-DRN-DT-Z SYMBOL 7 White 9 0.30 Ditch Inlet (Top Elevation) SP-E-DRN-EM SHORTDASH 110 Green 9 0.30 Edge of MuskegSP-E-DRN-EM-P CONTINUOUS 110 Green 9 0.30 Muskeg Pattern

app9-surveys Page 3 of 9

Page 89: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionSP-E-DRN-EW CONTINUOUS 154 Cyan 8 0.50 Edge of WaterSP-E-DRN-FR-Z SYMBOL 140 Cyan 9 0.30 Frustrum ElevationSP-E-DRN-MH SYMBOL 170 Blue 9 0.30 Manhole San. or SewerSP-E-DRN-RR GR-DRIVE 70 Yellow/Green 9 0.30 Rip-RapSP-E-DRN-SAN CONTINUOUS 130 Cyan 9 0.30 Sanitary Sewer PipesSP-E-DRN-SEW CONTINUOUS 130 Cyan 9 0.30 Storm Sewer PipesSP-E-DRN-SU-Z SYMBOL 150 Cyan 9 0.30 Sump ElevationSP-E-DRN-WM CONTINUOUS 160 Blue 9 0.30 Water MarkSP-E-DRN-T TEXT25 2 Yellow 254 0.25 Drainage Text ============== Ground Feature Layers ==============SP-E-GND-AO CONTINUOUS 50 Yellow 9 0.30 Asphalt OutlineSP-E-GND-AS CONTINUOUS 40 Orange 9 0.30 Asphalt ShotsSP-E-GND-BA CONTINUOUS 140 Cyan 9 0.30 Bank of River or StreamSP-E-GND-BC GR-DRIVE 100 Green 9 0.30 Bottom of Rock CutSP-E-GND-CO CONTINUOUS 180 Blue 9 0.30 Concrete Outline SP-E-GND-CS CONTINUOUS 150 Cyan 9 0.30 Concrete Shots SP-E-GND-DS CONTINUOUS 120 Green 9 0.30 Door Sill SP-E-GND-EC LONGDASH 20 Red 9 0.30 Entrance CenterlineSP-E-GND-GO GR-DRIVE 40 Orange 9 0.30 Gravel OutlineSP-E-GND-GS CONTINUOUS 40 Orange 9 0.30 Gravel ShotsSP-E-GND-OG CONTINUOUS 210 Magenta 9 0.30 Original Ground FaultSP-E-GND-PG SYMBOL 210 Magenta 9 0.30 Original Ground PointSP-E-GND-RBE SHORTDASH 40 Orange 9 0.30 Railway Ballast EdgeSP-E-GND-RBT CONTINUOUS 40 Orange 9 0.30 Railway Ballast TopSP-E-GND-RKO CONTINUOUS 50 Yellow 9 0.30 Rock OutlineSP-E-GND-RKS CONTINUOUS 50 Yellow 9 0.30 Rock ShotsSP-E-GND-SB CONTINUOUS 190 Magenta 9 0.30 River or Stream BedSP-E-GND-SP GR-DRIVE 40 Orange 9 0.30 Stock Piles - Gravel PitsSP-E-GND-TC CONTINUOUS 100 Green 9 0.30 Top of Rock CutSP-E-GND-TS GR-DRIVE 120 Green 9 0.30 Toe of SlopeSP-E-GND-P CONTINUOUS 110 Green 9 0.30 Ground Patterning (ie. Cut - Fill)SP-E-GND-T TEXT25 2 Yellow 254 0.25 Ground Feature Text

app9-surveys Page 4 of 9

Page 90: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Miscellaneous Layers ==============SP-Q-MSC-AU CONTINUOUS 7 White 9 0.30 Audit LineSP-E-MSC-BLO CONTINUOUS 230 Red 9 0.30 Building Outline (Bottom)SP-E-MSC-BN SYMBOL 20 Red 9 0.30 Centre of Bull NoseSP-E-MSC-BRP SYMBOL 180 Blue 9 0.30 Bridge Pillar SP-E-MSC-BY CONTINUOUS 7 White 9 0.30 Segment BoundarySP-E-MSC-CE CONTINUOUS 180 Blue 9 0.30 Cemetery SP-E-MSC-DD SYMBOL 230 Red 9 0.30 Deck DrainSP-E-MSC-DK CONTINUOUS 40 Orange 9 0.30 Wooden Decks or DocksSP-E-MSC-EJ CONTINUOUS 210 Magenta 9 0.30 Expansion JointSP-E-MSC-EV-Z SYMBOL 80 Yellow/Green 9 0.30 Miscellaneous ElevationSP-E-MSC-GAB CONTINUOUS 70 Yellow/Green 9 0.30 Gabion BasketsSP-E-MSC-GFL SYMBOL 20 Red 9 0.30 Gate with Flashing LightSP-E-MSC-HR CONTINUOUS 60 Yellow 9 0.30 Bridge Hand RailsSP-E-MSC-OS CONTINUOUS 130 Cyan 9 0.30 Overhead SignSP-E-MSC-RCS SYMBOL 20 Red 9 0.30 Railway Crossing SignSP-E-MSC-RLS SYMBOL 20 Red 9 0.30 Railway SignSP-E-MSC-RLT CONTINUOUS 20 Red 9 0.30 Railway - Top of RailSP-E-MSC-RW CONTINUOUS 70 Yellow/Green 9 0.30 Retaining Wall - BottomSP-E-MSC-SW CONTINUOUS 20 Red 9 0.30 SidewalkSP-E-MSC-WW SHORTDASH 40 Orange 9 0.30 Walkways - Trails - PathsSP-E-MSC-T TEXT25 2 Yellow 254 0.25 Miscellaneous Text ============== Property Boundary Layers ==============SP-E-BDY-CITY SUBGRADE 245 Red 252 0.60 City BoundarySP-E-BDY-LIN LONGDASH 24 Red 8 0.50 General Property Boundary LineSP-E-BDY-LLS LONGDASH 24 Red 8 0.50 Lot Line - Subdivision BoundarySP-E-BDY-LLC SYMBOL 20 Red 9 0.30 Lot Line - Concession BoundarySP-E-BDY-T TEXT25 2 Yellow 254 0.25 Property Boundary Text

app9-surveys Page 5 of 9

Page 91: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Right of Way Layers ==============SP-E-ROW-MTO ROW 70 Yellow 9 1.00 Existing MTO PropertySP-E-ROW-T TEXT25 2 Yellow 254 0.25 Right of Way Text ============== Roadway Layers ==============SP-E-RDS-AE CONTINUOUS 50 Yellow 9 0.30 Asphalt EdgesSP-E-RDS-BRD CONTINUOUS 230 Red 9 0.30 Bridge DeckSP-E-RDS-CR CONTINUOUS 130 Cyan 9 0.30 Crown of RoadSP-E-RDS-CU CONTINUOUS 70 Yellow/Green 9 0.30 CurbsSP-E-RDS-DL DASHED 130 Cyan 9 0.30 Driving Lane - EdgeSP-E-RDS-EG CONTINUOUS 240 Red 9 0.30 Edge Of GutterSP-E-RDS-EP CONTINUOUS 63 Yellow 253 0.40 Edge Of PavementSP-E-RDS-ER CONTINUOUS 50 Yellow 9 0.30 Edge Of RampSP-E-RDS-ES GR-DRIVE 40 Orange 9 0.30 Edge Of ShoulderSP-E-RDS-NG GR-DRIVE 40 Orange 9 0.30 Entrance - GravelSP-E-RDS-NP CONTINUOUS 50 Yellow 9 0.30 Entrance - PavedSP-E-RDS-RS CONTINUOUS 210 Magenta 9 0.30 Ripple StripSP-E-RDS-SR CONTINUOUS 50 Yellow 9 0.30 Sideroads PavedSP-E-RDS-UR GR-ROAD 40 Orange 9 0.30 Gravel SideroadsSP-E-RDS-T TEXT25 2 Yellow 254 0.25 Roadway Text

app9-surveys Page 6 of 9

Page 92: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== Survey Monument Layers ==============SP-E-MON SYMBOL 20 Red 9 0.30 Cut Cross Concrete Monument Concrete Pin Primary Horizontal Control Point Horizontal Project Control Point Iron Bar Nail, Spike, Rock Rivet, etc Rock Bar Round Iron Bar Rock Plug Rock Post Standard Iron Bar Short Standard Iron Bar Primary Vertical Control Point Vertical Project Control PointSP-G-MON-T TEXT25 2 Yellow 254 0.25 Monument Text ============== Utility Layers ==============SP-E-UTL-AN SYMBOL 210 Magenta 9 0.30 AnchorSP-E-UTL-BH SYMBOL 7 White 9 0.30 Bell - Hydro PoleSP-E-UTL-BP SYMBOL 7 White 9 0.30 Bell PoleSP-E-UTL-FH SYMBOL 7 White 9 0.30 Fire HydrantSP-E-UTL-GV SYMBOL 7 White 9 0.30 Gas ValveSP-E-UTL-HCG-Z CONTINUOUS 140 Cyan 9 0.30 Hydro Crossing Ground ElevSP-E-UTL-HCW-Z CONTINUOUS 7 White 9 0.30 Hydro Crossing Wire ElevSP-E-UTL-HP SYMBOL 7 White 9 0.30 Hydro PoleSP-E-UTL-HT CONTINUOUS 7 White 9 0.30 Hydro TowerSP-E-UTL-LS SYMBOL 7 White 9 0.30 Light StandardSP-E-UTL-PL CONTINUOUS 50 Yellow 9 0.30 PipelineSP-E-UTL-PO SYMBOL 7 White 9 0.30 Pole - other

app9-surveys Page 7 of 9

Page 93: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionSP-E-UTL-PW SYMBOL 50 Yellow 9 0.30 Pole WellSP-E-UTL-TB SYMBOL 50 Yellow 9 0.30 Utility Terminal BoxSP-E-UTL-UB CABLE 40 Orange 9 0.30 Underground BellSP-E-UTL-UG CABLE 40 Orange 9 0.30 Underground GasSP-E-UTL-UH CABLE 40 Orange 9 0.30 Underground HydroSP-E-UTL-UM SYMBOL 50 Yellow 9 0.30 Underground Utility MarkerSP-E-UTL-UT CABLE 40 Orange 9 0.30 Underground Utility - otherSP-E-UTL-VE SYMBOL 50 Yellow 9 0.30 VentSP-E-UTL-WE SYMBOL 140 Cyan 9 0.30 WellSP-E-UTL-WV SYMBOL 140 Cyan 9 0.30 Water ValveSP-E-UTL-T TEXT25 2 Yellow 254 0.25 Utilities Text ============== Vegetation Layers ==============SP-E-VEG-HE HEDGE 100 Green 9 0.30 HedgeSP-E-VEG-P CONTINUOUS 90 Green 9 0.30 Bush SymbologySP-E-VEG-TR SYMBOL 90 Green 9 0.30 TreesSP-E-VEG-WD BUSH 90 Green 9 0.30 Woods DetailSP-E-VEG-WO BUSH 90 White 9 0.30 Woods Overhang (Ground)SP-E-VEG-WT CONTINUOUS 50 Yellow 9 0.30 Woods TrunklineSP-E-VEG-T TEXT25 2 Yellow 254 0.25 Vegetation Text ============== Profile Layers ==============SP-P-ALI-CL CONTINUOUS 3 Green 253 0.40 Profile InformationSP-P-ALI-DRN CONTINUOUS 63 Yellow 253 0.40 Drainage InformationSP-P-ALI-DRN-T TEXT25 2 Yellow 254 0.25 Profile TextSP-P-ALI-GRID CONTINUOUS 1 Red 251 0.20 Profile GridSP-P-ALI-GRID-T TEXT25 2 Yellow 254 0.25 Profile Chainage

app9-surveys Page 8 of 9

Page 94: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ==================== LEGAL SURVEYS Layers ====================SP-L-MON SYMBOL 20 Red 9 0.30 Horizontal Control PointsSP-L-MON-BM SYMBOL 20 Red 9 0.30 Bench MarksSP-G-MON-T TEXT25 2 Yellow 254 0.25 Monument TextSP-L-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm LineSP-L-25MM-SDASH SHORTDASH 2 Yellow 254 0.25 0.25mm LineSP-L-25MM-LDASH LONGDASH 2 Yellow 254 0.25 0.25mm LineSP-L-40MM CONTINUOUS 3 Green 253 0.40 0.40mm LineSP-L-40MM-LDASH LONGDASH 3 Green 253 0.40 0.40mm LineSP-L-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm LineSP-L-PART CONTINUOUS 6 Magenta 135 0.75 0.75mm LineSP-L-TEXT TEXT 2 Yellow 254 0.25 Legal TextSP-L-SYMBOLS SYMBOL 2 Yellow 254 0.25 Legal Symbols

app9-surveys Page 9 of 9

Page 95: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-10

LAYER STANDARDS

For

STRUCTURAL DRAWINGS

Page 96: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:ST - Structural Design

Status (B): The following abbreviations are used:N - New Construction G - General E - Existing F - Future R - Removal

Feature (CCC): The feature portion of the layer name is generally defined by a single component.

Associated Layer (CC): The following abbreviations are used:(This layer is optional) T - Text D - Dimension P - Pattern RB - Rebar

NOTE: These layers are generated only when a user decides to select the "By Pick" option when inserting dimensions, text,pattern (hatching) or rebar for a feature. The proprieties of these layers are similar to the general layers for dimension(ST-G-DIM), text (ST-G-TEXT), pattern (hatch) (ST-G-HATCH) and the reinforcing steel (ST-E-REBAR and ST-N-REBAR).See the On-line help for the Structural customisation for more details.

For example, if a user has 2 features on a drawing for a new bridge say abutment and pier. The two features will be on theST-N-ABUT and ST-N-PIER layers. The customisation has two options for selecting layers for the dimensions for thesefeatures. In option 1, the dimensions for the abutment and pier can be placed in the general layer ST-G-DIM. In option 2,the user selects dimension by pick and the customisation will generate a ST-N-ABUT-D layer for the abutment dimensionsand a ST-N-PIER-D layer for the dimensions for the pier. The proprieties of the ST-N-ABUT-D and ST-N-PIER-D layersare the same as the proprieties for the ST-G-DIM layer.

STRUCTURAL DESIGN LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC )

app10-structural Page 1 of 5

Page 97: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) Description =============== Common Layers ===============BORDER CONTINUOUS 6 Magenta 135 0.75 BordersDWGINFO CONTINUOUS 7 White 9 0.30 Drawing InfoVPORTS CONTINUOUS 4 Cyan 8 0.50 View Port =============== General Layers ===============ST-G-SYMBOLS CONTINUOUS 40 Orange 9 0.30 Structural symbolsST-G-CENTLN CENTER2 1 Red 251 0.20 Center LineST-G-CONS CONTINUOUS 53 254 0.25 Construction lines 0.25mmST-G-60MM CONTINUOUS 5 Blue 135 0.60 Detail Linework 0.60mmST-G-50MM CONTINUOUS 4 Cyan 8 0.50 Detail Linework 0.50mmST-G-40MM CONTINUOUS 3 Green 253 0.40 Detail Linework 0.40mmST-G-30MM CONTINUOUS 7 White 9 0.30 Detail Linework 0.30mmST-G-25MM CONTINUOUS 2 Yellow 254 0.25 Detail linework 0.25mmST-G-DIM CONTINUOUS 1 Red 251 0.20 All dimensionsST-G-TEXT CONTINUOUS 7 White 9 0.30 All General Text AnnotationST-G-HATCH CONTINUOUS 1 Red 251 0.20 All hatchingST-G-MARKUP CONTINUOUS 7 White 9 0.30 MarkupST-G-MISC CONTINUOUS 7 White 9 0.30 entities not covered by StandardST-G-SCANNED CONTINUOUS 7 White 9 0.30 Scanned =============== Reinforcing Steel ===============ST-E-REBAR CONTINUOUS 5 252 0.60 Reinforcing SteelST-N-REBAR CONTINUOUS 5 Blue 252 0.60 Reinforcing Steel =============== Substructures ===============ST-E-ABUT CONTINUOUS 40 Grey 9 0.30 Abutment and Wingwall ST-E-BRG CONTINUOUS 50 Grey 9 0.30 BearingST-E-CONTOUR HIDDEN 113 Grey 253 0.40 Contours

app10-structural Page 2 of 5

Page 98: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionST-E-EARTHEXT CONTINUOUS 40 Grey 9 0.30 Existing earth ST-E-EARTHMOD CONTINUOUS 40 Grey 9 0.30 Modified earth ST-E-FOOT CONTINUOUS 50 Grey 9 0.30 Footing ST-E-PIER CONTINUOUS 40 Grey 9 0.30 Pier ST-E-PILE CONTINUOUS 104 Grey 8 0.50 PileST-E-RSOIL CONTINUOUS 40 Grey 9 0.30 Retained Soil System ST-E-RWALL CONTINUOUS 210 Grey 9 0.30 Retaining Wall ST-E-TEMP CONTINUOUS 40 Grey 9 0.30 Temporary Work ST-N-ABUT CONTINUOUS 40 Orange 9 0.30 Abutment and Wingwall ST-N-BRG CONTINUOUS 50 Yellow 9 0.30 BearingST-N-CONTOUR HIDDEN 113 Green 253 0.40 ContoursST-N-EARTHEXT CONTINUOUS 40 Orange 9 0.30 Existing earth ST-N-EARTHMOD CONTINUOUS 40 Orange 9 0.30 Modified earth ST-N-FOOT CONTINUOUS 50 Yellow 9 0.30 Footing ST-N-PIER CONTINUOUS 40 Orange 9 0.30 Pier ST-N-PILE CONTINUOUS 104 Green 8 0.50 PileST-N-RSOIL CONTINUOUS 40 Orange 9 0.30 Retained Soil System ST-N-RWALL CONTINUOUS 210 Magenta 9 0.30 Retaining Wall ST-N-TEMP CONTINUOUS 40 Orange 9 0.30 Temporary Work =============== Super Structures ===============ST-E-APPR CONTINUOUS 80 Grey 9 0.30 Approach Slab ST-E-ASPH CONTINUOUS 160 Grey 9 0.30 Asphalt and waterproofing ST-E-BWAL CONTINUOUS 140 Grey 9 0.30 Barrier and Parapet wall 0.30mmST-E-CABL CONTINUOUS 160 Grey 9 0.30 Cable and Tendon ST-E-DECK CONTINUOUS 20 Grey 9 0.30 Deck ST-E-EXJT CONTINUOUS 230 Grey 9 0.30 Expansion Joint 0.30mmST-E-GIRD CONTINUOUS 40 Grey 9 0.30 Girder - X-Frame - P. T. Deck 0.30mmST-E-TRUSS CONTINUOUS 50 Grey 9 0.30 Truss 0.30mmST-N-APPR CONTINUOUS 80 Green 9 0.30 Approach Slab ST-N-ASPH CONTINUOUS 160 Blue 9 0.30 Asphalt and waterproofing ST-N-BWAL CONTINUOUS 140 Cyan 9 0.30 Barrier and Parapet wall 0.30mmST-N-CABL CONTINUOUS 160 Blue 9 0.30 Cable and Tendon

app10-structural Page 3 of 5

Page 99: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionST-N-DECK CONTINUOUS 20 Red 9 0.30 Deck ST-N-EXJT CONTINUOUS 230 Red 9 0.30 Expansion Joint 0.30mmST-N-GIRD CONTINUOUS 40 Orange 9 0.30 Girder - X-Frame - P. T. Deck 0.30mmST-N-TRUSS CONTINUOUS 50 Yellow 9 0.30 Truss 0.30mm =============== Roadway ===============ST-E-ALIG CONTINUOUS 70 Grey 9 0.30 Control Alignment ST-E-PAVT CONTINUOUS 160 Grey 9 0.30 Pavement and Traffic Lanes ST-E-PROF CONTINUOUS 20 Grey 9 0.30 Road Profile ST-E-CURB CONTINUOUS 70 Grey 9 0.30 Curb ST-N-ALIG CONTINUOUS 70 Green 9 0.30 Control Alignment ST-N-PAVT CONTINUOUS 160 Blue 9 0.30 Pavement and Traffic Lanes ST-N-PROF CONTINUOUS 20 Red 9 0.30 Road Profile ST-N-CURB CONTINUOUS 70 Green 9 0.30 Curb =============== Other Structures ===============ST-E-CULV CONTINUOUS 160 Grey 9 0.30 Culvert ST-E-HMPOLE CONTINUOUS 130 Grey 9 0.30 High Mast Lighting Pole and Base 0.30mmST-E-SIGN CONTINUOUS 210 Grey 9 0.30 Sign and Sign Support 0.30mmST-E-SOILPRT CONTINUOUS 210 Grey 9 0.30 Soil Protection - Concrete Slope Paving ST-N-CULV CONTINUOUS 160 Blue 9 0.30 Culvert ST-N-HMPOLE CONTINUOUS 130 Cyan 9 0.30 High Mast Lighting Pole and Base 0.30mmST-N-SIGN CONTINUOUS 210 Magenta 9 0.30 Sign and Sign Support 0.30mmST-N-SOILPRT CONTINUOUS 210 Magenta 9 0.30 Soil Protection - Concrete Slope Paving =============== Miscellaneous Features ===============ST-E-CAMB CONTINUOUS 150 Grey 9 0.30 Camber Diagram ST-E-ELEC CONTINUOUS 50 Grey 9 0.30 Electrical Embedded Work ST-E-RAILING CONTINUOUS 160 Grey 9 0.30 RailingST-E-RAILWAY CONTINUOUS 20 Grey 9 0.30 Railway ST-E-UTIL CONTINUOUS 210 Grey 9 0.30 Utility (Bell-Hydro etc.)

app10-structural Page 4 of 5

Page 100: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorPlot

Color#

Pen Thickness

(mm) DescriptionST-E-WALK CONTINUOUS 160 Grey 9 0.30 Sidewalk ST-N-CAMB CONTINUOUS 150 Blue 9 0.30 Camber Diagram ST-N-ELEC CONTINUOUS 50 Yellow 9 0.30 Electrical Embedded Work ST-N-RAILING CONTINUOUS 160 Blue 9 0.30 RailingST-N-RAILWAY CONTINUOUS 20 Red 9 0.30 Railway ST-N-UTIL CONTINUOUS 210 Magenta 9 0.30 Utility (Bell-Hydro etc.) ST-N-WALK CONTINUOUS 160 Blue 9 0.30 Sidewalk

app10-structural Page 5 of 5

Page 101: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-11

LAYER STANDARDS

For

TRAFFIC DRAWINGS

Page 102: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:TR - Traffic

Status (B): The following abbreviations are used:E - Existing ConditionsN - New Construction ConditionsT - Temporary (Schematic)

Feature (CCC-CC): The feature portion of the layer name is generally defined by 2 components. - the 1st portion indentifies a feature group - the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:

PMK - Pavement MarkingsSIGN - Sign

Application of the IES CAD Layer Standards( AA-B-CCC-CC-D )

TRAFFIC LAYER DEFINITIONS- January 2004 -

app11-traffic Page 1 of 4 26/07/2005

Page 103: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ============== General Layers ==============BORDER CONTINUOUS 6 Magenta 135 0.75 Frame - Title Block BordersDWGINFO CONTINUOUS 7 White 9 No Plot Drawing Specific Information VPORTS CONTINUOUS 4 Cyan 8 No Plot View Port - Paper Space Limits TR-G-CONS CONTINUOUS 8 8 No Plot Construction (working) lineTR-G-DIM CONTINUOUS 132 254 General dimensionsTR-G-HATCH CONTINUOUS 1 251 General hatch patternTR-G-TEXT TEXT 3 9 General text ============== Existing Pavement Markings ==============TR-E-PMK-ARROWS CONTINUOUS 22 Red 254 0.25 Turning ArrowsTR-E-PMK-BW1 PMK1 3 Green 253 0.40 Broken line for left and right turn lane (3,-3,10)TR-E-PMK-BW2 PMK1 43 Brown 253 0.40 Continuity line in channelizations (3,-3,20)TR-E-PMK-BW3 PMK2 43 Brown 253 0.40 Lane dividing line (3,-6,10)TR-E-PMK-BW4 PMK3 3 Green 253 0.40 Lane dividing line (3,-9,10)TR-E-PMK-BY1 PMK1 3 Green 253 0.40 Broken yellow for two way left turn lane (3,-3,10)TR-E-PMK-BY2 PMK2 3 Green 253 0.40 Directional dividing lines (center line) ( 3,-6,10)TR-E-PMK-CROSSWALK CONTINUOUS 43 Brown 253 0.40 Crosswalk linesTR-E-PMK-GORE CONTINUOUS 3 Green 253 0.40 Gore areaTR-E-PMK-STOPBAR CONTINUOUS 91 Green 251 0.20 Intersection stop barTR-E-PMK-SW1 CONTINUOUS 43 Brown 253 0.40 Edge lines, Lane lines (10cm width)TR-E-PMK-SW2 CONTINUOUS 3 Brown 253 0.40 Edge line (20cm width)TR-E-PMK-SY CONTINUOUS 43 Brown 253 0.40 Center line ============== New Construction Pavement Markings ==============TR-N-PMK-ARROWS CONTINUOUS 22 254 Turning ArrowsTR-N-PMK-BW1 PMK1 3 Green 253 0.40 Broken line for left and right turn lane (3,-3,10)TR-N-PMK-BW2 PMK1 43 Brown 253 0.40 Continuity line in channelizations (3,-3,20)TR-N-PMK-BW3 PMK2 43 Brown 253 0.40 Lane dividing line (3,-6,10)TR-N-PMK-BW4 PMK3 3 Green 253 0.40 Lane dividing line (3,-9,10)

app11-traffic Page 2 of 4 26/07/2005

Page 104: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) DescriptionTR-N-PMK-BY1 PMK1 3 Green 253 0.40 Broken yellow for two ways left turn lane (3,-3,10)TR-N-PMK-BY2 PMK2 3 Green 253 0.40 Directional dividing lines (center line) ( 3,-6,10)TR-N-PMK-CROSSWALK CONTINUOUS 43 Brown 253 0.40 Crosswalk linesTR-N-PMK-GORE CONTINUOUS 3 Green 253 0.40 Gore areaTR-N-PMK-STOPBAR CONTINUOUS 91 Green 251 0.20 Intersection stop barTR-N-PMK-SW1 CONTINUOUS 43 Brown 253 0.40 Edge line, lane line (10cm width)TR-N-PMK-SW2 CONTINUOUS 3 Green 253 0.40 Edge line (20cm width)TR-N-PMK-SY CONTINUOUS 43 Brown 253 0.40 Center line ============== Typical Drawing Pavement Markings ==============TR-T-PMK-ARROWS CONTINUOUS 22 254 Turning ArrowsTR-T-PMK-BW1 PMK1 3 Green 253 0.40 Broken line for left and right turn lane(3,-3,10)TR-T-PMK-BW2 PMK1 43 Brown 253 0.40 Continuity line in channelizations (3,-3,20)TR-T-PMK-BW3 PMK2 43 Brown 253 0.40 Lane dividing line (3,-6,10)TR-T-PMK-BW4 PMK3 3 Green 253 0.40 Lane dividing line (3,-9,10)TR-T-PMK-BY1 PMK1 3 Green 253 0.40 Broken yellow for two ways left turn lane (3,-3,10)TR-T-PMK-BY2 PMK2 3 Green 253 0.40 Directional dividing lines (center line) ( 3,-6,10)TR-T-PMK-CROSSWALK CONTINUOUS 43 Brown 253 0.40 Crosswalk linesTR-T-PMK-GORE CONTINUOUS 3 Green 253 0.40 Gore areaTR-T-PMK-STOPBAR CONTINUOUS 91 Green 251 0.20 Intersection stop barTR-T-PMK-SW1 CONTINUOUS 3 Green 253 0.40 Edge line, lane line (10cm width)TR-T-PMK-SW2 CONTINUOUS 3 Green 253 0.40 Edge line (20cm width)TR-T-PMK-SY CONTINUOUS 43 Brown 253 0.40 Center line ==============Existing Signs ==============TR-E-SIGN-REG SYMBOL 3 Green 253 0.40 Regulatory SignsTR-E-SIGN-WARN SYMBOL 3 Green 253 0.40 Warning SignsTR-E-SIGN-GUID CONTINUOUS 3 Green 253 0.40 Guide SignsTR-E-SIGN-MUN CONTINUOUS 3 Green 253 0.40 Municipal boundry and population signsTR-E-SIGN-TEMP CONTINUOUS 3 Green 253 0.40 Temporary conditions and construction signsTR-E-SIGN-TOUR CONTINUOUS 3 Green 253 0.40 Tourism and tourist route signsTR-E-SIGN-SPEC CONTINUOUS 3 Green 253 0.40 Special signs (eg. border crossing/temp.signs)

app11-traffic Page 3 of 4 26/07/2005

Page 105: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color# ColorHalf-Tone

Color#

Pen Thickness

(mm) Description ==============New Construction Traffic Signs ==============TR-N-SIGN-REG SYMBOL 3 Green 253 0.40 Regulatory SignsTR-N-SIGN-WARN SYMBOL 3 Green 253 0.40 Warning SignsTR-N-SIGN-GUID CONTINUOUS 3 Green 253 0.40 Guide SignsTR-N-SIGN-MUN CONTINUOUS 3 Green 253 0.40 Municipal boundry and population signsTR-N-SIGN-TEMP CONTINUOUS 3 Green 253 0.40 Temporary conditions and construction signsTR-N-SIGN-TOUR CONTINUOUS 3 Green 253 0.40 Tourism and tourist route signsTR-N-SIGN-SPEC CONTINUOUS 3 Green 253 0.40 Special signs (eg. border crossing/temp.signs) ==============Typical Drawing Traffic Signs ==============TR-T-SIGN-REG SYMBOL 3 Green 253 0.40 Regulatory SignsTR-T-SIGN-WARN SYMBOL 3 Green 253 0.40 Warning SignsTR-T-SIGN-GUID CONTINUOUS 3 Green 253 0.40 Guide SignsTR-T-SIGN-MUN CONTINUOUS 3 Green 253 0.40 Municipal boundry and population signsTR-T-SIGN-TEMP CONTINUOUS 3 Green 253 0.40 Temporary conditions and construction signsTR-T-SIGN-TOUR CONTINUOUS 3 Green 253 0.40 turism and tourist route signsTR-T-SIGN-SPEC CONTINUOUS 3 Green 253 0.40 Special signs ( e.g. border crossing/temp.signs

app11-traffic Page 4 of 4 26/07/2005

Page 106: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-12

LAYER STANDARDS

For

GEOTECHNICAL DRAWINGS

Page 107: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:GE - Geotechnical Design

Status (B): The following abbreviations are used:N - New Construction G - General E - Existing F - Future R - Removal

Feature (CCC): The feature portion of the layer name is generally defined by a single component.

Associated Layer (CC): The following abbreviations are used:(This layer is optional) T - Text D - Dimension P - Pattern RB - Rebar

GEOTECHNICAL DESIGN LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC )

app12-geotech Page 1 of 5

Page 108: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color#Plot

Color#

Pen Weight (mm)

Description

=============== Common Layers ===============BORDER CONTINUOUS 6 135 0.70 Border - Frame - Title BlockDWGINFO CONTINUOUS 7 9 0.00 Drawing InfoVPORTS CONTINUOUS 4 8 0.00 View PortsGE-N-MAP-SYM-CONT SYMBOL 6 135 0.70 Contract numberGE-N-MAP-SYM-NTH SYMBOL 196 135 0.70 North arrow symbolGE-N-MAP-SYM-SCE SYMBOL 90 9 0.30 Symbol for source position ============== Pit Layers ==============GE-N-PIT-SYM-AUG SYMBOL 1 251 0.20 Symbol for boreholeGE-N-PIT-SYM-BAC SYMBOL 2 254 0.25 Test Pit Dug by BackhoeGE-E-PIT-SYM-BED SYMBOL 110 9 0.30 Symbol for bed rockGE-E-PIT-SYM-BLG SYMBOL 21 251 0.20 Symbol for buildingGE-E-PIT-SYM-BUS BUSH 120 9 0.30 Symbol for bushGE-E-PIT-SYM-CON SYMBOL 231 251 0.20 Symbol for coniferousGE-E-PIT-SYM-DEC SYMBOL 241 251 0.20 Symbol for deciduousGE-E-PIT-SYM-FAC SYMBOL 1 251 0.20 Symbol for pit faceGE-E-PIT-SYM-FEN FENCE 110 9 0.30 FenceGE-E-PIT-SYM-HL SYMBOL 21 251 0.20 Symbol for power lineGE-E-PIT-SYM-HWY SYMBOL 91 251 0.20 Symbol for highwayGE-E-PIT-SYM-MAR SYMBOL 1 251 0.20 Symbol for marshGE-E-PIT-MISC-TC CONTINUOUS 100 9 0.30 Top of Pit FaceGE-E-PIT-MISC-TS GR-DRIVE 100 9 0.30 Toe of SlopeGE-N-PIT-MISC-LE CONTINUOUS 100 9 0.30 Limit of ExtractionGE-E-PIT-SYM-PIP SYMBOL 21 251 0.20 Symbol for pipelineGE-E-PIT-SYM-RIV CONTINUOUS 130 9 0.30 Bank of River or StreamGE-E-PIT-SYM-RR SYMBOL 1 251 0.20 Symbol for rail roadGE-E-PIT-SYM-SLO SYMBOL 120 9 0.30 Symbol for slope arrowsGE-E-PIT-SYM-STR SYMBOL 1 251 0.20 Symbol for structureGE-E-PIT-SYM-TEL SYMBOL 1 251 0.20 Symbol for telephone lineGE-E-PIT-SYM-TWP GR-ROAD 40 9 0.30 Township road

app12-geotech Page 2 of 5

Page 109: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color#Plot

Color#

Pen Weight (mm)

Description

GE-N-PIT-TEXT-GRID CONTINUOUS 5 252 0.60 Title grid textGE-N-PIT-TEXT-TLE CONTINUOUS 226 135 0.70 Title block textGE-E-PIT-MISC-BNDP CONTINUOUS 6 135 0.70 Permit BoundaryGE-E-PIT-MISC-BNDS DASHED2 6 135 0.70 Permit SetbackGE-E-PIT-MISC-RAST CONTINUOUS 21 251 0.20 Raster ImageGE-E-PIT-SYM-GA CONTINUOUS 90 9 0.30 GateGE-E-PIT-MISC-SP GR-DRIVE 40 9 0.30 Stock Piles - Gravel PitsGE-E-PIT-MISC-C1 CONTINUOUS 255 9 0.30 Contours - PrimaryGE-E-PIT-MISC-C2 CONTINUOUS 251 253 0.20 Contours - SecondaryGE-E-PIT-MISC-T TEXT25 2 254 0.25 Contours Text ============== Typical Layers ==============GE-N-TYP-BASE-AT CONTINUOUS 1 251 0.20 Asphalt Treated BaseGE-N-TYP-BASE-CT CONTINUOUS 21 251 0.20 Cement treated baseGE-N-TYP-BASE-GRAN CONTINUOUS 231 251 0.20 Granular A BaseGE-N-TYP-BASE-GRO CONTINUOUS 241 251 0.20 Granular OGE-N-TYP-BASE-OGD CONTINUOUS 1 251 0.20 Open graded drainage layerGE-N-TYP-BASE-PCC CONTINUOUS 21 251 0.20 Portland Concrete BaseGE-N-TYP-BIN-HDB CONTINUOUS 90 9 0.30 Heavy duty binder courseGE-N-TYP-BIN-HL2 CONTINUOUS 100 9 0.30 HL-2 binder courseGE-N-TYP-BIN-HL3 CONTINUOUS 110 9 0.30 HL-3 binder courseGE-N-TYP-BIN-HL4 CONTINUOUS 120 9 0.30 HL-4 binder courseGE-N-TYP-BIN-HL8 CONTINUOUS 90 9 0.30 HL-8 binder courseGE-N-TYP-BIN-MDB CONTINUOUS 100 9 0.30 Medium Duty Binder CourseGE-N-TYP-BIN-RHM CONTINUOUS 110 9 0.30 Recycled Binder CourseGE-N-TYP-ERTH-CUT CONTINUOUS 1 251 0.20 Earth CutGE-N-TYP-ERTH-FIL CONTINUOUS 21 251 0.20 Earth FillGE-N-TYP-MISC-BT CONTINUOUS 231 251 0.20 Bituthene tapeGE-N-TYP-MISC-CB CONTINUOUS 241 251 0.20 Catch BasinGE-N-TYP-MISC-CG CONTINUOUS 21 251 0.20 Curb and gutterGE-N-TYP-MISC-DB CONTINUOUS 231 251 0.20 Dowel barGE-N-TYP-MISC-GEO CONTINUOUS 241 251 0.20 GeotextileGE-N-TYP-MISC-GR CONTINUOUS 1 251 0.20 Guide rail

app12-geotech Page 3 of 5

Page 110: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color#Plot

Color#

Pen Weight (mm)

Description

GE-N-TYP-MISC-JT CONTINUOUS 90 9 0.30 JointGE-N-TYP-MISC-LTD CONTINUOUS 1 251 0.20 Load transfer deviceGE-N-TYP-MISC-MH CONTINUOUS 21 251 0.20 ManholeGE-N-TYP-MISC-MIL CONTINUOUS 231 251 0.20 Mill/coldplaneGE-N-TYP-MISC-RIP CONTINUOUS 241 251 0.20 Rip-rapGE-N-TYP-MISC-R&F CONTINUOUS 100 9 0.30 Rout and FillGE-N-TYP-MISC-R&S CONTINUOUS 110 9 0.30 Rout and SealGE-N-TYP-MISC-SEW CONTINUOUS 1 251 0.20 SewerGE-N-TYP-MISC-SOD CONTINUOUS 21 251 0.20 SodGE-N-TYP-MISC-SUB CONTINUOUS 120 9 0.30 Sub DrainGE-N-TYP-MISC-TAC CONTINUOUS 90 9 0.30 Tack coatGE-N-TYP-MISC-TIE CONTINUOUS 1 251 0.20 Tie barGE-N-TYP-MISC-TPS CONTINUOUS 21 251 0.20 TopsoilGE-N-TYP-SUB-CLR CONTINUOUS 231 251 0.20 Clear stoneGE-N-TYP-SUB-GRA CONTINUOUS 241 251 0.20 Granular A subbaseGE-N-TYP-SUB-GRB CONTINUOUS 1 251 0.20 Granular B subbaseGE-N-TYP-SUB-SSM CONTINUOUS 21 251 0.20 Select subgrade materialGE-N-TYP-SUBQ-ERTH CONTINUOUS 231 251 0.20 Earth SubgradeGE-N-TYP-SUBQ-MUS CONTINUOUS 241 251 0.20 MuskegGE-N-TYP-SUBQ-ORG CONTINUOUS 1 251 0.20 OrganicsGE-N-TYP-SUBQ-RK CONTINUOUS 21 251 0.20 Rock SubgradeGE-N-TYP-SUBQ-RK-CUT CONTINUOUS 231 251 0.20 Rock CutGE-N-TYP-SUBQ-RK-FILL CONTINUOUS 241 251 0.20 Rock FillGE-N-TYP-SUBQ-STR CONTINUOUS 1 251 0.20 Rock ShatterGE-N-TYP-SUBQ-SWP CONTINUOUS 21 251 0.20 SwampGE-N-TYP-SUBQ-WAT CONTINUOUS 143 8 0.40 WaterGE-N-TYP-SURF-CIP CONTINUOUS 90 9 0.30 Cold in place resurfacingGE-N-TYP-SURF-DFC CONTINUOUS 100 9 0.30 DFC surface courseGE-N-TYP-SURF-GRA CONTINUOUS 1 251 0.20 Granular A surfaceGE-N-TYP-SURF-HIP CONTINUOUS 110 9 0.30 Hot in place resurfacingGE-N-TYP-SURF-HL1 CONTINUOUS 120 9 0.30 HL1 surface courseGE-N-TYP-SURF-HL3 CONTINUOUS 90 9 0.30 HL3 surface courseGE-N-TYP-SURF-HL4 CONTINUOUS 100 9 0.30 HL4 surface courseGE-N-TYP-SURF-MIC CONTINUOUS 110 9 0.30 Micro surfacing

app12-geotech Page 4 of 5

Page 111: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color#Plot

Color#

Pen Weight (mm)

Description

GE-N-TYP-SURF-OFC CONTINUOUS 120 9 0.30 OFC surface courseGE-N-TYP-SURF-PCC CONTINUOUS 90 9 0.30 Portland Concrete SurfaceGE-N-TYP-SURF-RHM CONTINUOUS 100 9 0.30 RHM surface courseGE-N-TYP-SURF-ST CONTINUOUS 1 251 0.20 Surface treatmentGE-N-TYP-TEXT-GRID CONTINUOUS 5 252 0.60 Title grid textGE-N-TYP-TEXT-TLE CONTINUOUS 6 135 0.70 Title block text

app12-geotech Page 5 of 5

Page 112: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

MTO AutoCAD Standards Guide January 2004 Version 2004

APPENDIX A-13

LAYER STANDARDS

For

FOUNDATIONS DRAWINGS

Page 113: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Discipline (AA): The following abbreviations are used:FD - Foundation Design

Status (B): The following abbreviations are used:N - New Construction G - General E - Existing F - Future R - Removal

Feature (CCC): The feature portion of the layer name is generally defined by a single component.

Associated Layer (CC): The following abbreviations are used:(This layer is optional) T - Text D - Dimension P - Pattern RB - Rebar

FOUNDATIONS DESIGN LAYER DEFINITIONS- January 2004 -

Application of the IES CAD Layer Standards( AA-B-CCC-CC )

app13-foundations Page 1 of 3

Page 114: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color#Plot

Color#

Pen Weight

(mm)Description

============== Layers ==============BORDER CONTINUOUS 6 135 0.70 Border - Frame - Title BlockDWGINFO CONTINUOUS 7 9 0.00 Drawing InfoVPORTS CONTINUOUS 4 8 0.00 View PortsFD-E-BASE100-T SYMBOL 132 254 0.25 Sheet Scale = 100'FD-E-BASE50-T SYMBOL 132 254 0.25 Sheet Scale = 50'FD-E-CHART_FRAME SYMBOL 254 254 0.25 Sheet BorderFD-E-CHART_TEXT-T CONTINUOUS 132 254 0.25 Sheet TextFD-E-CONEPLOT1 SYMBOL 92 254 0.25 Cone Graph On p.1FD-E-CONEPLOT2 SYMBOL 92 254 0.25 Cone Graph On p.2FD-E-CONEPLOT3 SYMBOL 92 254 0.25 Cone Graph On p.3FD-E-CONEPLOT4 SYMBOL 92 254 0.25 Cone Graph On p.4FD-E-CONEPLOT5 SYMBOL 92 254 0.25 Cone Grapg On p.5FD-E-DESC1-T CONTINUOUS 2 254 0.25 Description Text On p.1FD-E-DESC2-T CONTINUOUS 2 254 0.25 Description Text On p.2FD-E-DESC3-T CONTINUOUS 2 254 0.25 Description Text On p.3FD-E-DESC4-T CONTINUOUS 2 254 0.25 Description Text On p.4FD-E-DESC5-T CONTINUOUS 2 254 0.25 Description Text On p.5FD-E-ELEVSCAL1 SYMBOL 142 254 0.25 Elevation Text On p.1FD-E-ELEVSCAL2 SYMBOL 142 254 0.25 Elevation Text On p.2FD-E-ELEVSCAL3 SYMBOL 142 254 0.25 Elevation Text On p.3FD-E-ELEVSCAL4 SYMBOL 142 254 0.25 Elevation Text On p.4FD-E-ELEVSCAL5, SYMBOL 142 254 0.25 Elevation Text On p.5FD-E-GNDWATER1 SYMBOL 212 254 0.25 Ground Water On p.1FD-E-GNDWATER2 SYMBOL 212 254 0.25 Ground Water On p.2FD-E-GNDWATER3 SYMBOL 212 254 0.25 Ground Water On p.3FD-E-GNDWATER4 SYMBOL 212 254 0.25 Ground Water On p.4FD-E-GNDWATER5 SYMBOL 212 254 0.25 Ground Water On p.5FD-E-LOGO SYMBOL 254 254 0.25 MTO LogoFD-E-SAMPLES1 SYMBOL 2 254 0.25 Soil Samples On p.1FD-E-SAMPLES2 SYMBOL 2 254 0.25 Soil Samples On p.2FD-E-SAMPLES3 SYMBOL 2 254 0.25 Soil Samples On p.3

app13-foundations Page 2 of 3

Page 115: AutoCAD Standards Guide - Ontario Standards Guide... · AutoCAD Standards Guide Version 2004 ... ONTARIO PROVINCIAL STANDARD DRAWINGS ... As the fundamental element of integration,

Layer LineStyleFull-Tone

Color#Plot

Color#

Pen Weight

(mm)Description

FD-E-SAMPLES4 SYMBOL 2 254 0.25 Soil Samples On p.4FD-E-SAMPLES5 SYMBOL 2 254 0.25 Soil Samples On p.5FD-E-VANES1 SYMBOL 2 254 0.25 Vanes On p.1FD-E-VANES2 SYMBOL 2 254 0.25 Vanes On p.2FD-E-VANES3 SYMBOL 2 254 0.25 Vanes On p.3FD-E-VANES4 SYMBOL 2 254 0.25 Vanes On p.4FD-E-VANES5 SYMBOL 2 254 0.25 Vanes On p.5

app13-foundations Page 3 of 3