attachment 8.2 sop.docx

Upload: muslim

Post on 01-Nov-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

ATTACHMENT 8.2

Preliminary Preparation (done by Operation Technician)1) Ensure that the special requirements are fulfilled. The special requirement include :

Mandatory PPE requirement Identify the hazards such as toxic liquid, pressurised fluid, loud noise, and hydrocarbon release The common handtools use for the work The walkie talkie are functioning with clear Ensure the communication with SOR is established

2) Ensure the MSDS is in place for reference.3) Ensure that vendor recommendation report for injection is in place for reference.4) Confirm with SOR that the task is ready to be carried out.

Preparation of Demulsifier Injection System ( done by Operation Technician)

1) Ensure and verify this following valves are lines up as this requirement :

Valve noLocation Position

CI 1001Fill connection at east boat landing (not in use)Closed

CI 1002Fill connection to T 1Closed

CI 1003Fill connection to T 2Closed

CI 1004Tank T 1 inletOpen

CI 1005Tank T 1 outletOpen

CI 1006Tank T 2 inletOpen

CI 1007Tank T 2 outletOpen

CI 1008P-1/P-2 common suction lineOpen

CI 1009P-1 suction from T-2 tank (alternative)Closed

CI 1010P-1 suctionClosed

CI 1011P-1 dischargeOpen

CI 1012P-1 dischargeLO

CI 1013P-2 suctionOpen

CI 1014P-2 dischargeOpen

CI 1015P-2 dischargeOpen

CI 1016RV 2874 outletLO

IG 1001P-1 gas supplyClosed

IG 1002P-2 gas supplyClosed

2) Check that the storage tank T-1/T-2 contains adequate supply of demulsifier and refill as necessary.3) Ensure that ulitility gas system is in normal operating mode and that utility gas supply is available to pump.4) Check that the pumps are calibrated for the required injection rate.

Demulsifier injection system operation procedure (done by Operation Technician)

1) Open the IG 1001/IG 1002 utility gas supply valve to the pump.2) Monitor the performance of the pump to see any abnormal condition that may occur. If the condition is normal, skip step 3,4, and 5.3) Adjust the injection rate if required by opening CI 1009 inlet valve to the calibration gauge. Fill the calibration gauge.4) When the calibtaion gauge is full, close the discharge CI 1008 header valve.5) After the adjustment, open suction CI 1008 header valve and close CI 1009 calibration gauge valve as required.6) Regularly check the level in the demulsifier storage tanks and replenish as necessary.

Preparation of biocide injection system (done by Operation Technician)

1) Ensure biocide storage tank level is sufficient by monitoring the level gauge. Replenish as necessary.2) Ensure biocide pump in good condition.

Biocide Injection system operation procedure (done by Operation Technician)

1) Open the biocide storage tank outlet to the pump.2) Open the pump suction and discharge valve.3) Open the isolation valves provided on the fitting located at the injection point.4) Open the gas supply valve to the pump to start the duty pump.5) Slowly increase the stroke by adjusting the speed controller and observe the pump discharge pressure according to the rate required.6) Stop the pump by closing the gas supply valve upon completing the injection of the target amount.7) Close the pump suction and discharge valve and biocide storage tank outlet valve to the pump.8) Confirm with SOR upon completing of biocide injection activity.9) Perform housekeeping and keep record of the actities in log book.

Preparation for CI injection system (done by Operation Technician)

1) Check the CI level in the storage tank at correct operating level between 10% and 80% on daily basis. Replenish as necessary.2) Ensure CI pump in good condition.3) Ensure that utility gas supply is available to pump.

CI system injection procedure (done by Operation Technician)

1) Open the CI storage tank outlet to the pump.2) Open the pump suction and discharge valve.3) Open the isolation valve provided on the fitting located at the injection point.4) Open the main gas supply valve to the pump to start the duty pump.5) Slowly increase the stroke by adjusting the speed controller and observe the pump discharge pressure according to rate required.6) Perform housekeeping and keep the record of the activities in log book.