attachment 1: lot 415 (no. 43) marlow street, wembley · 2c facebrick boundary wall with physical...
TRANSCRIPT
The Town of Cambridge does not warrant the accuracy of information in this publication and any person using or relying upon such information does so on the basis that the Town of Cambridge shall bear no responsibility or liability whatsoever for any errors, faults, defects or omissions in the information. 1:1000
DV18.181 - ATTACHMENT 1: Lot 415 (No. 43) Marlow Street, Wembley
Attachment 2 Development application site photographs
Property Lot 415 (No. 43) Marlow Street, Wembley Proposal Two Grouped Dwellings DA reference 0163DA-2018 Date of photographs
11 October 2018
Photograph 1: Subject site
Photograph 2: View of subject site looking south
ADDRESS:
CLIENT: AMENDMENTS:
LOT 415 (#43) MARLOW ST
T. YOUNG & N. SNOOKSJOB NUMBER:
20380-20381
\\abn.group\abnfile\wbJobs\Drafting\20000\20300\20380\20380-20381 SITE PLAN.pln
GENERAL INFO:
COUNCIL
ZONING
CONSULTANT
ESTATE
OPEN SPACE:
SITE LOT AREA
ALLOWED SITE COVER
ACTUAL SITE COVER
HOUSE TYPE:Designer:Designer:
Design Date:WEMBLEY
© THE COPYRIGHT OF THIS DESIGN IS THE SOLE PROPERTY OF WEBB & BROWN-NEAVES PTY LTD TRADING AS apg HOMES AND THERE IS NO IMPLIED LICENCE FOR ITS USE FOR ANY PURPOSE
Individual
CAMBRIDGE
R20
VANCE JENKIN
ESTABLISHED
1084m²
50%
530m²
JP
V2 - 20/04/18 - SRV3 - 23/04/18 - SR PL1 - 22/05/18 - SR
24.08.18
51%
.
1:200cJ/N: DATE: DRAWN:SCALE:
Licensed Surveyors
87-89 Guthrie Street, Osborne Park, Western Australia
Telephone: (08) 9446 7361 Facsimile: (08) 9445 2998
Email : [email protected] Website: www.cottage.com.au
SEC DomePower PolePhone Pits
LEG
END
T C
TP10.00TWTRTF
[[[[
10.0010.0010.00
]]]]
Top Pillar/PostTop WallTop RetainingTop Fence
W Water Conn.
Marlow StreetBitumen
Non-MountNil
Concrete Footpath
OLDAREA
W
S
E
N
427371 13 Nov 17 M. Bateman
Builder : APGCLIENT : Young & SnooksLOT 415 #43 Marlow Street, Wembley
Plan3185
47.2
7
22.9390 °0
'0 "
47.2
7
90 °0 '0 "
22.93
90°0'
0"
9.709.79
11.55 9.7
5
9 .56
9.68
9 .68
11
.32
9.61
9.5
8
9 .81
9.7
8
9 .66
9.7
3
9.64
11.55
9.7
19
.80
9 .80
9.7
7
9.9
4
9.90
9.8
6
10.69
9.7
79
.72
9 .589
.66
9.5
7
9.60
9.5
2
11
.10
9.60
9.519 .6 1
11.18
9.6
29
.68
9.6
99
.75
9.8
09
.83
11.55
12
.03
9 .88
9 .94
9.9
3
10.4510.00
9 .94
9 .96
9 .95
9 .96
1 0 .01
1 0 .02
9.93
10
.06
9.88
10.01
9.95
9 .75
10
.01
10
.00
9.99
9.9
69
.99
10
.02
1 0 .00
10.5010.06
10 .05
1 0 .01
1 0 .04
1 0 .00
1 0 .04
1 0 .01
1 0 .01
1 0 .02
1 0 .05
1 0 .12
1 0 .02
9.9710.0510.03
9.959.9310.009.92
9.91
>>>
CD
rive
Opp
.>>>
CD
rive
Opp
.
>>>
CD
rive
Opp
.
Pow
er P
ole
Opp
.
>>>
Nil
BitumenCrossoverBitumen
Crossover
ConcreteCrossover
T
Ref Nail At Edge Of RoadAssumed Datum 10.00 m
Meter W
Verge TreeØ 0.80mHt 8.0m
Verge TreeØ 0.55mHt 8.0m
L/GrassL/Grass
C
10
.06
L/Grass
9.7
19
.64
9.8
09
.77
9.8
69
.93
TP[ ]
9.6
0
FibroFence FairCondition(Capped)
Approx F.L10.31
Brick & TileCarport
BrickPillar
CarportUMR
TF[ ]
TF[ ]
TF[ ]
9.7
79
.72
9.6
6
9.68 9.339.51
TF[]
TF[]
Sew
er I.
O.
FibroFence FairCondition
9.519.41
TF[ ]
GalvShedGalv
Shed
TimberFence Good
Condition(Capped)
FibroFence FairCondition
9.6
89
.89
Alum.Shed
9.7
5
BrickWall With
Pillars
LowBrickWall
9.8
09
.83
Alum.Shed
10.02
9.9
6
TF ]
TimberPatio
TP[]
Brick & TileCarport
BrickWall With
Pillars
Alum.Shed
TW[ ]
LowBrickWall
T
Gate
NOTE/BEWARE:ADVISE TRADESO/Head power lines
CornerObstructed
Brick & TileOn Limestone
(F.L Unobt.Locked Gate)
#45
#41Brick & Tile
On Limestone
Brick & TileOn Slab
Brick & GalvOn Slab2-Storey Brick,
W/Board & TileOn Slab
Brick & TileOn Slab
Sewer JunctionUp: 1.1Approx. Inv: 6.8Approx. Depth: 1.7Approx. Sewer OnlyCheck Water Corp.
Approximate Sewer OnlyCheck Water Corporation For JunctionInvert and Depth
NOTE:
Sewer JunctionUp: 1.4Approx. Inv: 6.6Approx. Depth: 1.5Approx. Sewer OnlyCheck Water Corp.
Approximate Sewer OnlyCheck Water Corporation For JunctionInvert and Depth
NOTE:
PEGGONE
PEGGONE
PEGGONE
PEGGONE
10.0
10.0
10.0
10.0
NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.
W
90mm PVC PRELAY90mm PVC PRELAY
6,620
29,390
11,260
500
400
2,345
7,26
0
7,26
0
1,055
1,555
6,52
0
6,00
0
7,52
0
7,52
0
6,32
0
1,20
0
1,020
1,520
1,18
0
6,620
29,390
11,260
6,12
01,
400
7,52
07,
790
6,02
0
6,02
0
55 5520
20
12,485 10,390 55
1,520
1,520
1,555
1,020
1,555
6,52
08,
490
750 3,000 1,590 3,000
3,480
1,867
158.18 m2
11.465m
11.465m 11.465m
PROPOSEDWATER METERLOCATION
PORCH
PROPOSEDPOWER DOME
LOCATION
REFER TO WB/APG OFFICE FORALL SERVICE PLANS BEFORE
ANY EARTHWORKS COMMENCE(DBYD J/N: 14723902)
RELOCATEEXISTINGWATERMETER
RL 10.10
B/PAVEDPATH
PROPOSEDRESIDENCE
(20380)UNIT 1
0c FFL 10.20
PROPOSEDRESIDENCE
(20381)UNIT 2
0c FFL 10.20
GARAGECONC AT -1cFFL 10.114
GARAGECONC AT -1cFFL 10.114
PAVED AT -1cFFL 10.114
ALFRESCOPAVED AT -1cFFL 10.114
ALFRESCO
RGL: 10.05RGL: 10.05
PAVE
D A
T -1
cPAVE
D A
T -1
cPA
VED
AT
-1c
PAVE
D A
T -1
c
COLORBONDRETAINING
T.O.W. 10.09B.O.W. 09.64
OVERSHADOWING:
14.5%
RL 10.10
RL 1
0.10
RL 1
0.10
PORCH
B/PAVEDPATH
COLORBONDRETAINING
T.O.W. 10.10B.O.W. 09.65
BOU
ND
ARY
WAL
L
B/PAVEDDRIVE
B/PAVEDCROSSOVERBY BUILDER
B/PAVEDDRIVE
B/PAVEDCROSSOVERBY BUILDER
CONC APRON BY BUILDER CONC APRON BY BUILDER
20380 - UNIT 1
20381 - UNIT 2
PRO
POSE
D B
OU
ND
ARY
LIN
E
BOU
ND
ARY
WAL
L
90 °0 '0 "
COMBM/BOX
COMBM/BOX
1,055 10,390 11,485
FRONT SETBACK LANDSCAPING AREA
20380 (UNIT 1) 39.44m² (57.43%)20381 (UNIT 2) 39.61m² (57.58%)
PROPOSED SITE PLAN1:200
DATE
BUILDER
OWNER
OWNER
Attachnent 3
ADDRESS:
CLIENT: AMENDMENTS:
U1 LOT 415 (#43) MARLOW ST
T. YOUNG & N. SNOOKSJOB NUMBER:
20380
\\abn.group\abnfile\wbJobs\Drafting\20000\20300\20380\20380.pln
GENERAL INFO:
COUNCIL
ZONING
CONSULTANT
ESTATE
OPEN SPACE:
SITE LOT AREA
ALLOWED SITE COVER
ACTUAL SITE COVER
HOUSE TYPE:Designer:Designer:
Design Date:WEMBLEY
© THE COPYRIGHT OF THIS DESIGN IS THE SOLE PROPERTY OF WEBB & BROWN-NEAVES PTY LTD TRADING AS apg HOMES AND THERE IS NO IMPLIED LICENCE FOR ITS USE FOR ANY PURPOSE
Individual
CAMBRIDGE
R20
VANCE JENKIN
ESTABLISHED
542m²
50%
265m²
JP
V2 - 20/04/18 - SRV3 - 23/04/18 - SRPL1 - 23/05/18 - SR
24.08.18
51%
LAM. PTY
18x
1810
18x
1810
18x
610
AO
BSC
12x
710
FO
BSC
25x
1810
SD2434x5290 STACKER
RECESSED SILL 28x610 A
28x
3010
28x
3010
28x
910
8x3
010
14x
610
FO
BSC
14x
1410
OBS
C
20x SP A
20x
SP
F
920TF
9202340H
9202340H
920CAVITY SD
28c
SLID
ING
DO
ORS
& T
IMBE
R FR
AM
ED W
ALL
8202340H
8202340H
28c SLIDING DOORS& FASTWALL LINTEL
9202340H
9202340H
9202340H
8202340H
9202340H
2x8
20SD
REMOTE CONTROLSECTIONAL DOOR
920
1170x570R.A.G.
ELEC PRELAY
WM
FR REC
T.O.
F. -5
cT.
O.F.
-5c
1170x570R.A.G.
RWP
RWP
RWP
RWP
RWP
RWP
RWP RWP
RWP
RWP
RWP
RWPRWP
1,020
1,055
1,555
1,520
1,40
07,
790
13,0
107,
690
4,00
0
6,12
033
,890
7,26
0
9,01
04,
910
5,29
01,
410
2,39
07,
000
4,00
0
6,00
034
,010
7,26
0
6,090 1,210 2,810 1,180 100
55 5,685 405
7,52
0
55 11,390 20E2
E4
E3
E1
32c
GU
TTER
ON
2c
FAC
E BR
ICK
BOU
ND
ARY
WAL
L W
ITH
PH
YSIC
AL T
ERM
ITE
BARR
IER
1135
x535
A.C
BO
X O
UT
CAPPEDGAS PT
A/C
UN
IT
GASHWU
ATTIC STORAGEAREA 13m²
600x1300ATTIC LADDER
35c
GU
TTER
ON
2c
FAC
E BR
ICK
BOU
ND
ARY
WAL
L W
ITH
PH
YSIC
AL T
ERM
ITE
BARR
IER
ENTRY
STORE
ALFRESCO
MEDIA
BED 1
BED 2
BED 3
WC
BATH
ENS
L'DRY
WC
WIR
GARAGE
PORCH
LIVING
BIR
BIR
SCULLERY
NOOK
LINEN
KITCHENFW
COMBM/BOX
FW
FW
FW
FW
DINING
DESIGN NOTES24°43' ROOF PITCHCOLORBOND ROOF
31c+PL GROUND FLOOR UNO
RENDERED BWK EXTERNALLY
AREAS.....
STOREGROUND FLOORGARAGEPORCHALFRESCO
6.75225.1646.463.59
35.56317.52 m2
( 81.560m)
GROUND FLOOR1:100
DATE
BUILDER
OWNER
OWNER
ADDRESS:
CLIENT: AMENDMENTS:
U1 LOT 415 (#43) MARLOW ST
T. YOUNG & N. SNOOKSJOB NUMBER:
20380
\\abn.group\abnfile\wbJobs\Drafting\20000\20300\20380\20380.pln
GENERAL INFO:
COUNCIL
ZONING
CONSULTANT
ESTATE
OPEN SPACE:
SITE LOT AREA
ALLOWED SITE COVER
ACTUAL SITE COVER
HOUSE TYPE:Designer:Designer:
Design Date:WEMBLEY
© THE COPYRIGHT OF THIS DESIGN IS THE SOLE PROPERTY OF WEBB & BROWN-NEAVES PTY LTD TRADING AS apg HOMES AND THERE IS NO IMPLIED LICENCE FOR ITS USE FOR ANY PURPOSE
Individual
CAMBRIDGE
R20
VANCE JENKIN
ESTABLISHED
542m²
50%
265m²
JP
V2 - 20/04/18 - SRV3 - 23/04/18 - SRPL1 - 23/05/18 - SR
24.08.18
51%
2,69
2
CONTRASTING RENDER 2
RENDER 1
SELECTED TIMBER CLADDING
REMOTE SECTIONALDOOR
CL 31c + PL
FL 0c
21c
28c
40c
30c
25c
41c
2,95
0
2,69
2
3,75
6
3,15
9
450
2c FACEBRICK BOUNDARY WALLWITH PHYSICAL TERMITE BARRIER
NATURAL GROUND LINE AT B'DRY
PROPOSED RETAINING WALLTOP @ 10.09
TOF -5c
CL 34c + PL
FL 0c
CL 31c + PL
FL 0c
34c
28c
32c
41c
30c 28c
2,95
0
NATURAL GROUND LINE AT B'DRY
CL 34c + PL
FL 0c
2,69
2
2,95
0OBSC OBSC2c FACEBRICK BOUNDARY WALLWITH PHYSICAL TERMITE BARRIER
CL 31c + PL
FL 0c
CL 34c + PL
FL 0c
28c 31c
35c
DESIGN NOTES24°43' ROOF PITCHCOLORBOND ROOF
31c+PL GROUND FLOOR UNO
RENDERED BWK EXTERNALLY
ELEVATION 11:100
ELEVATION 21:100
ELEVATION 31:100
ELEVATION 41:100
DATE
BUILDER
OWNER
OWNER
ADDRESS:
CLIENT: AMENDMENTS:
U2 LOT 415 (#43) MARLOW ST
T. YOUNG & N. SNOOKSJOB NUMBER:
20381
\\abn.group\abnfile\wbJobs\Drafting\20000\20300\20381\20381.pln
GENERAL INFO:
COUNCIL
ZONING
CONSULTANT
ESTATE
OPEN SPACE:
SITE LOT AREA
ALLOWED SITE COVER
ACTUAL SITE COVER
HOUSE TYPE:Designer:Designer:
Design Date:WEMBLEY
© THE COPYRIGHT OF THIS DESIGN IS THE SOLE PROPERTY OF WEBB & BROWN-NEAVES PTY LTD TRADING AS apg HOMES AND THERE IS NO IMPLIED LICENCE FOR ITS USE FOR ANY PURPOSE
Individual
CAMBRIDGE
R20
VANCE JENKIN
ESTABLISHED
542m²
50%
265m²
JP
V2 - 20/04/18 - SRV3 - 23/04/18 - SRPL1 - 23/05/18 - SR
24.08.18
51%
LAM. PTY
920
18x
1810
18x
1810
18x
610
AO
BSC
12x
710
FO
BSC
25x
1810
SD
2434x5290 STACKERRECESSED SILL
28x610 A
28x
3010
28x
3010
28x
910
8x3
010
14x
610
FO
BSC
14x
1410
OBS
C
20x
SP
F
920TF
9202340H
9202340H
920CAVITY SD
28c
SLID
ING
DO
ORS
& T
IMBE
R FR
AM
ED W
ALL
8202340H
8202340H
28c SLIDING DOORS& FASTWALL LINTEL
9202340H
9202340H
9202340H
8202340H
9202340H
2x8
20SD
REMOTE CONTROLSECTIONAL DOOR
20x SP A
1170x570R.A.G.
ELEC PRELAY
WM
FR REC
1170x570R.A.G.
RWP
RWP
RWP
RWP
RWP
RWP
RWP RWP
RWP
RWP
RWP
RWPRWP
T.O.F. -4cT.O.F. -4c
1,055
1,020
1,520
1,555
6,12
033
,890
7,26
0
1,40
07,
790
13,0
107,
690
4,00
0
6,52
033
,490
7,26
0
200
8,49
04,
910
5,29
01,
410
2,39
07,
000
4,00
0
5,560 590 1,150 4,090
20 11,390 55
6,32
0
7,52
0
E2
E4
E3
E1
32c
GU
TTER
ON
2c
FAC
E BR
ICK
BOU
ND
ARY
WAL
L W
ITH
PH
YSIC
AL T
ERM
ITE
BARR
IER
1135
x535
A.C
BO
X O
UT
CAPPEDGAS PT
A/C
UN
IT
GASHWU
600x1300ATTIC LADDER
32c
GU
TTER
ON
2c
FAC
E BR
ICK
BOU
ND
ARY
WAL
L W
ITH
PH
YSIC
AL T
ERM
ITE
BARR
IER
RENDERED BRICK SCREENWALL T.O.W. AT 13c
ATTIC STORAGE AREA13m²
ENTRY
STORE
ALFRESCO
MEDIA
BED 1
BED 2
BED 3
WC
BATH
ENS
L'DRY
WC
WIR
GARAGE
PORCH
LIVING
BIR
BIR
SCULLERY
NOOK
LINEN
KITCHENFW
COMBM/BOX
FW
FW
FW
FW
DINING
DESIGN NOTES24°43' ROOF PITCHCOLORBOND ROOF
31c+PL GROUND FLOOR UNO
RENDERED BWK EXTERNALLY
AREAS.....
STOREGROUND FLOORGARAGEPORCHALFRESCO
6.75225.1646.463.83
35.56317.76 m2
( 12.000m)( 81.560m)
GROUND FLOOR1:100
DATE
BUILDER
OWNER
OWNER
ADDRESS:
CLIENT: AMENDMENTS:
U2 LOT 415 (#43) MARLOW ST
T. YOUNG & N. SNOOKSJOB NUMBER:
20381
\\abn.group\abnfile\wbJobs\Drafting\20000\20300\20381\20381.pln
GENERAL INFO:
COUNCIL
ZONING
CONSULTANT
ESTATE
OPEN SPACE:
SITE LOT AREA
ALLOWED SITE COVER
ACTUAL SITE COVER
HOUSE TYPE:Designer:Designer:
Design Date:WEMBLEY
© THE COPYRIGHT OF THIS DESIGN IS THE SOLE PROPERTY OF WEBB & BROWN-NEAVES PTY LTD TRADING AS apg HOMES AND THERE IS NO IMPLIED LICENCE FOR ITS USE FOR ANY PURPOSE
Individual
CAMBRIDGE
R20
VANCE JENKIN
ESTABLISHED
542m²
50%
265m²
JP
V2 - 20/04/18 - SRV3 - 23/04/18 - SRPL1 - 23/05/18 - SR
24.08.18
51%
2,69
2
RENDER 1
FEATURE FACE BRICKIN STACK BOND
REMOTE SECTIONALDOOR
CL 31c + PL
FL 0c
21c 28c
36c 39c
28c
36c
2,95
0
2,69
2
3,23
6
2,98
2
2c FACEBRICK BOUNDARY WALLWITH PHYSICAL TERMITE BARRIER
CL 34c + PL
FL 0c
CL 31c + PL
FL 0c
34c
28c
32c
39c
21c
28c
2,95
0
CL 34c + PL
FL 0c
2,69
2
2,95
044
1
3,06
6
3,01
9
3,30
1 OBSC OBSC2c FACEBRICK BOUNDARY WALLWITH PHYSICAL TERMITE BARRIER
NGL AT BOUNDARY LINE SHOWN DASHEDTOF -4c
PROPOSED RETAINING WALLTOP @ 10.10
CL 31c + PL
FL 0c
CL 34c + PL
FL 0c
28c 31c 32c
DESIGN NOTES24°43' ROOF PITCHCOLORBOND ROOF
31c+PL GROUND FLOOR UNO
RENDERED BWK EXTERNALLY
ELEVATION 11:100
ELEVATION 21:100
ELEVATION 31:100
ELEVATION 41:100
DATE
BUILDER
OWNER
OWNER
ADDRESS:
CLIENT: AMENDMENTS:
LOT 415 (#43) MARLOW ST
T. YOUNG & N. SNOOKSJOB NUMBER:
20380-20381
\\abn.group\abnfile\wbJobs\Drafting\20000\20300\20380\20380-20381 SITE PLAN.pln
GENERAL INFO:
COUNCIL
ZONING
CONSULTANT
ESTATE
OPEN SPACE:
SITE LOT AREA
ALLOWED SITE COVER
ACTUAL SITE COVER
HOUSE TYPE:Designer:Designer:
Design Date:WEMBLEY
© THE COPYRIGHT OF THIS DESIGN IS THE SOLE PROPERTY OF WEBB & BROWN-NEAVES PTY LTD TRADING AS apg HOMES AND THERE IS NO IMPLIED LICENCE FOR ITS USE FOR ANY PURPOSE
Individual
CAMBRIDGE
R20
VANCE JENKIN
ESTABLISHED
1084m²
50%
530m²
JP
V2 - 20/04/18 - SRV3 - 23/04/18 - SR PL1 - 22/05/18 - SR
24.08.18
51%
STREET PERSPECTIVE
Attachment 4
ATTACHMENT 5: Applicant's Justification
LOT 415 (NO. 43) MARLOW STREET, WEMBLEY APPLICANT'S JUSTIFICATION "Two Boundary Walls / Height and Length Variation The proposed dwellings include boundary walls positioned at both the northern and southern sides of Lot 415 (subject land). The following variations are observed in relation to the proposed boundary walls associated with each dwelling. Unit 1 (20380)
• The northern boundary wall length measures 9.01m in lieu of 9.0m. • The southern boundary wall has an average height of 3.36m in lieu of 3.0m and
exceeds 3.5m in height at the facade. • The southern boundary wall has a length of 9.19m (garage + screen wall).
Unit 2 (20381) • The northern boundary wall has an average height of 3.027m in lieu of 3.0m. • The southern boundary wall has an average height of 3.109m in lieu of 3.0m. • The southern boundary wall has a length of 9.19m (garage + screen wall).
The deemed to comply criteria in Clause 5.1.3 of the Codes are replaced by Local Planning Policy (LPP) 3.2. The proposal is at variance to the Town’s LPP 3.2 and is therefore to be considered in light of the design principles in Clause 5.1.3 of the Codes, which are addressed as follows:
• The boundary walls are proposed in order to make the most productive use of the site, improving the level of internal space available within each dwelling. Each grouped dwelling site is generally constrained by a narrow width.
• Unit 2 features a proposed northern boundary wall associated with the Bedroom 1 / WIR section. The boundary wall features a height averaging slightly over 3.0m, at 3.027m, but well below the maximum 3.5m applicable. The wall is to be 8.49m in length, being less than the maximum 9m length required.
• The dwelling to the north of the subject land has an existing open sided carport within 3m of the front boundary, and a brick wall is positioned on the boundary. The proposed boundary wall associated with Unit 2 will adjoin the open sided carport and the space between the carport located forward of the dwelling. The boundary wall and minor variation to its height will not affect any major openings or private outdoor living areas, and will generate no significant overshadowing impacts on the dwelling to the north.
• Proposed Unit 1 includes a garage boundary wall positioned on the southern boundary. The wall averages 3.36m in height, exceeding the maximum average height of 3.0m required. The front façade treatment has a maximum height of 3.66m, slightly exceeding the maximum 3.5m required. Further, the entire wall length including the screen wall, measures 9.19m.
ATTACHMENT 5: Applicant's Justification
LOT 415 (NO. 43) MARLOW STREET, WEMBLEY
Figure 1 - Aerial View of Subject Land
• The Unit 1 garage boundary wall will adjoin a vehicle access-way immediately to the south as shown in the aerial image above, which provides access to a dwelling at the rear of #41 Marlow Street. The wall is shown to be well separated from the adjoining dwelling to the south due to the presence of this vehicle access - way.
• The Unit 1 boundary wall will also be positioned opposite an open sided carport,
and the space between the carport located forward of the adjoining dwelling. On this basis, the wall and variations proposed will not impact on any views from major openings, the private outdoor living area or pool shown to the rear of the adjoining dwelling. In addition, the boundary wall will not generate a pattern of overshadowing exceeding the requirements of the Codes, or impact on any major openings.The northern boundary wall associated with Unit 1 measures 9.01m in length, slightly exceeding the maximum 9.0m required. The southern boundary wall associated with Unit 2 has an average height of 3.109m in lieu of 3.0m, and a length of 9.19m. Given these two walls are proposed to adjoin each other centrally within the subject land, the minor height and length variation proposed for each wall will be screened from view on each adjoining property and generate no substantial amenity impacts.
• The image below shows a similar development outcome at #21 Alexander Street,
Wembley. However, this application will result in an improved level of streetscape amenity, given that a greater proportion of each dwelling is to be positioned forward of the garage structures.
ATTACHMENT 5: Applicant's Justification
LOT 415 (NO. 43) MARLOW STREET, WEMBLEY
Figure 2 – Development at 21 Alexander Street North Ground Floor Setbacks The ground floor Media Room and portion of the Living Room on each dwelling have a setback falling below the minimum 1.5m required under Table 2b of the Codes. The northern setback from these walls on Unit 1 is 1.02m, and for Unit 2 is 1.055m. The design principles in Clause 5.1.3 of the Codes are addressed as follows:
• The northern Media / Living Room walls associated with Unit 1 proposed to be setback below 1.5m measure 5.29m and 2.39m in length respectively. These walls will adjoin the side setback area of the proposed grouped dwelling to the north, and will not adjoin the proposed outdoor living area.
• Similarly, the northern Media / Living Room walls associated with Unit 2 will adjoin
the side setback area of the existing dwelling to the north. The site plans reveal that the majority of the ground floor wall associated with Unit 2 will be concealed by existing aluminum sheds positioned at the boundary on the adjoining lot.
• These aluminum sheds will conceal direct views to the majority of the wall and
greatly inhibit the potential for the total ground floor wall, and proposed variation, to generate any perception of significant excess building bulk.
• Furthermore, the majority of the ground floor wall of each grouped dwelling will be
screened by boundary fencing, limiting the extent of additional wall bulk that will be visible, while preserving visual privacy for the residents of Unit 2 and the existing dwelling to the north at #45 Marlow Street.
• The northern setback variations will generate no additional overshadowing impacts.
Open Space The combined area of the ground floor, garage and store associated with Units 1 and 2 measures 278.37m². Based on a site area of 542m² for each grouped dwelling, the extent of
ATTACHMENT 5: Applicant's Justification
LOT 415 (NO. 43) MARLOW STREET, WEMBLEY Open Space provided for each dwelling measures 48.6%, falling slightly below the minimum 50% required under Table 1 of the Codes. The design principles in Clause 5.1.4 of the Codes are addressed as follows:
• The proposed dwellings each feature complying front setbacks, exceeding the requirements of the Codes, and landscaping forward of each dwelling.
• The extent of each outdoor living area is compliant and ample space is provided for
outdoor pursuits and access around the edges of the dwelling. External fixtures and facilities are also able to be accommodated.
• The design of the dwelling facilitates natural light to north facing windows and ample
sunlight access to outdoor living areas.
• The extent of the variation is limited to 1.4% and therefore does not reflect significant overdevelopment of the site or excessive building bulk.
Vehicular Access The City’s Streetscape Policy states that for new infill developments, crossovers are to be no more than 4.5 m in width and that splays are to be contained within the 4.5m width. Further, the policy indicates a preference for access to be provided via a shared crossover, particularly for lots that have been formed through ‘down the middle subdivision’, creating narrow lots. The design principles in Clause 5.3.5 of the Codes are addressed to guide consideration of this variation to the Streetscape policy.
• Proposed Unit 1 and 2 each features crossovers having complying widths less than 4.5m, and with appropriate setbacks to existing street trees of >1.5m.
• The proposed extent of landscaped area forward of each dwelling is 57.43% for unit
1 and 57.58% for unit 2, just short of the 60% requirement. With the retention of the verge trees and the extent of proposed landscaping, this will enhance the existing streetscape.
• The proposed crossovers are to be established in the same location as the existing
crossovers that service the dwellings on the subject land. The proposal will therefore have limited impact on the streetscape given that no new or additional access points are proposed.
• The proposed crossovers are generally consistent with other similar infill
developments observed in the locality and suburb of Wembley that also have separate crossovers provided for each dwelling. These include the developments at 34/34a Reserve Street, 58/58a Marlow Street and 51/51a Simper Street. Other examples opposite the subject land include #48 and #54 Marlow Street, which feature two crossovers servicing one dwelling and limited landscaping forward of each dwelling.
• The proposed crossovers provide ample visibility for pedestrians and motorists, given that no screening is proposed forward of each dwelling inhibiting views from each driveway to the footpath".
ATTACHMENT 6: Schedule of Submissions
LOT 415 (NO. 43) MARLOW STREET, WEMBLEY NEIGHBOUR COMMENTS (1 of 2) "I am the owner of [address redacted] and have been invited to submit my comments to this planning application. According to your letter dated 30 October 2018 this development does not adhere to residential design codes / local planning policy in a multitude of state planning policy act 3.1 I object to allowing deviations to codes 5.1.3. Lot boundary setback. It should be maintained at 1.5 meters C3.1.12 Access and crossover. It should be no more than 4.5 meters in width. 3.2 Buildings on the Boundary. Height and length of boundary wall should be adhered to according to requirements. I have viewed the plans at council and object to these proposed deviations". NEIGHBOUR COMMENTS (2 of 2) "I recently viewed the plans for two grouped dwellings at 43 Marlow Street, Wembley. We do object to the buildings along the southern boundary of Unit 1 and along the northern boundary of unit 2. We understand the council does not encourage solid front walls so that the overall appearance in Wembley is open with leafy gardens. Solid boundary walls encourage closed cramped spaces and will cause ongoing problems with neighbours and residence. While the boundaries will not affect us directly on this occasion we are concerned for future development applications. We do trust you understand our concerns".