atex compliant diaphragm pumps - versa-maticvm.salesmrc.com/pdfs/vmatex_bro-rev0914_lowres.pdf2...
TRANSCRIPT
Vers
a-Mat
icS
OLU
TIO
NS
v e r S a m a T I c . c O m
• Chemical Transfer • Mine Dewatering • Food Processing • Metal Finishing • Ship Cleaning
ATEXVersa-Matic® Pumps
ATEX Compliant Diaphragm Pumps
Safety:Safety:ATEX compliant for
safe use in potentially explosive environments
BroadBroadMaterial Range:Material Range:
ATEX models available in an extensive range of metallic and
non-metallic conductive materials to handle virtually any medium safely
Multiple PumpMultiple PumpConfigurations:Configurations:
Both leak-free bolted and clamp designs available
WWW.VERSAMATIC.COM2 D E L I V E R I N G Q UA L I T Y, I N T E R C H A N G E A B L E P U M P I N G S O LU T I O N S
ATEX (Atmosphères Explosibles) is an acronym for the standard set by the European Parliament& Council of the European Union, recognized throughout the European Community as the safety standard for equipment used in potentially hazardous environments.
Why specify ATEX Compliant Pumps? Guaranteed Spark Free Safe Operation.FACT: Flammable gasses, vapors, mist, and dust as small as .03mm are explosive safety concerns when oxygen (air) is present and ignited. Products marked with the EX hexagon symbol followed by the Group and Category of safety protection indicates that the products are compliant with Directive 94/9/EC, according to Annex VIII.
Recognize the Components of ATEX Compliant Pumps.
NOTE: *See materials chart on back page for specific model details or consult the factory. (Grounding Strap sold separately - PN: 920.025.000)
CONDUCTIVE (ATEX COMPLIANT)CONDUCTIVE (ATEX COMPLIANT)• *Non-Wetted Conductive Materials:
• Conductive Acetal • Aluminum • Conductive Polypropylene • Stainless Steel
• Wetted Conductive Materials:• Conductive Acetal • Aluminum • Cast Iron • Alloy C• Conductive Polypropylene • Stainless Steel
• Fully groundable
• No isolated metallic hardware components
• Electrostatic discharges are dissipated in a continual current path throughout the pump to a natural ground
• Electrically conductive materials of construction
• ATEX Compliant means SAFE for use of equipment in potentially explosive environments, Zone 1 (gases) and Zone 21 (dusts), Gas Group IIB
ATEX SAFETY BENEFITSATEX SAFETY BENEFITS
ATEX Compliant Diaphragm PumpsKnow the Importance & Recognize the Components
WHAT IS ATEX?WHAT IS ATEX?
WWW.VERSAMATIC.COM 3
ATEX
D E L I V E R I N G Q UA L I T Y, I N T E R C H A N G E A B L E P U M P I N G S O LU T I O N S
NOTE: *See materials chart on back page for specific model details or consult the factory. (Grounding Strap sold separately - PN: 920.025.000)
WHAT IS ATEX?WHAT IS ATEX?
Versa-Matic® Metallic and Non-Metallic Pumps fully comply with ATEX requirements.
I M2 cII 3/2 GD c T5–Metallic II 3/2 GD c T6–Non-Metallic
Date of Issue:
10 May 2014
Technical File No.:
203104000-1410/MER
Quality System Registration No:
ISO 9001-2000
Directive:
94/9/EC 23 March 1994 Annex VIII
Conforming Apparatus:
Air-Operated Metal
Double Diaphragm Pumps for Use In Potentially
Explosive Atmospheres
Hazardous Location Applied:
1. II 3/2GD c T5*
T5fluidsupto
95°C
*Whenpumping
non-conductiv
efluidstheint
ernalsurfaces
that
contactthefl
uidarerestric
tedtoExII3G
DcT5.Theex
ternal
surfaces of the pump are still Ex II 2GD c T5.
2. I M2 c
fluidsupto95
°C
Pumps marked with equipment Category II 3/2 G
(internal 3 G / external 2 G), 2D, when used with
non-conductiv
efluids.Thep
umpsareCate
goryII2G
whenusedfor
conductiveflu
ids.
Manufacture:
Warren Rupp, Inc., A Unit of IDEX Corporation
800 North Main Street, P.O. Box 1568
Mansfield,OH
44901-1568
USA.
OnFileWith:
DEKRACertific
ationB.V.(034
4)
Meander 1051
6825 MJ Arnhem
The Netherlands
Harmonized Standards Applied:
EN 13463-1:2009 Non-Electrical Equipment
Potentially Explosive Atmospheres-Part 1 Basic
Methods and Requirements
EN 13463-5:2011 Non-Electrical Equipment for
Potentially Explosive Atmospheres-Part 5
Protection by Constructional Safety
Equipments:
1. Elima-Matic Series metal pumps for II 3/2GD c T5
2. Elima-Matic Series Cast Iron or Stainless Steel pumps
with Stainless Steel air center sections for I M2 c
We hereby certify that the equipment described above conforms with the protection requirements of Council Directive
94/9/EC of 23 March 1994 Annex VIII on the approximation of the laws of the Member States Concerning Equipment
and Protective Systems Intended for use in Potentially Explosive Atmospheres
DATE/OF REVISION/TITLE:
Dave Roseberry
29 May 2014
Engineering Manager
EC DECLARATION OF CONFORMITY
in accordance with ANNEX VIII of Directive 94/9/EC - Equipment for use in Potentially Explosive Atmospheres
VM_DofC_ATEX_Metallic_V_rev0514
Date of Issue: 10 May 2014Technical File No.: 203104000-1410/MERQuality System Registration No: ISO 9001-2000Directive:
94/9/EC 23 March 1994 Annex VIIIConforming Apparatus:
Air-Operated Conductive Polypropylene and
Conductive Acetal Double Diaphragm Pumps
for use in Potentially Explosive Atmospheres
Hazardous Location Applied: 1. II 3/2GD c T6*
T6fluidsupto80°C
*Whenpumpingnon-conductivefluidstheinternalsurfacesthat
contactthefluidarerestrictedtoExII3GDcT5.Theexternal
surfacesofthepumparestillExII2GDcT5.
Pumps marked with equipment Category II 3/2 G
(internal 3 G / external 2 G), 2D, when used with
non-conductivefluids.ThepumpsareCategoryII2G
whenusedforconductivefluids.Manufacture:
Warren Rupp, Inc., A Unit of IDEX Corporation
800NorthMainStreet,P.O.Box1568
Mansfield,OH44901-1568
USA.OnFileWith:DEKRACertificationB.V.(0344)
Meander1051
6825MJArnhem
The Netherlands Harmonized Standards Applied:
EN 13463-1:2009 Non-Electrical Equipment
PotentiallyExplosiveAtmospheres-Part1Basic
Methods and Requirements
EN13463-5:2011Non-ElectricalEquipmentfor
PotentiallyExplosiveAtmospheres-Part5
Protection by Constructional Safety Equipments:
1. Elima-Matic Series with any of the following
materials of construction are rated to II 3/2GD c T6:
Conductive Polypropylene and Conductive Acetal
fluidhousingswithAluminumorStainlessSteel
air center sectionsWe hereby certify that the equipment described above conforms with the protection requirements of Council Directive
94/9/EC of 23 March 1994 Annex VIII on the approximation of the laws of the Member States Concerning Equipment
and Protective Systems Intended for use in Potentially Explosive Atmospheres
DATE/OF REVISION/TITLE: Dave Roseberry
29 May 2014 Engineering Manager
EC DECLARATION OF CONFORMITYin accordance with ANNEX VIII of Directive 94/9/EC - Equipment for use in Potentially Explosive Atmospheres
VM_DofC_ATEX_Non-Metallic_V_rev0514
- Equipment intended for use in potentially explosive atmospheres
This safety compliance includes:• Filing a Technical Risk Assessment with a notified body. Versa-Matic files with DEKRA Certification B.V. Notified Body NO. 0344, The Netherlands Reference Number 203104000-1410/MER.
Requirements for compliance include, but are not limited to:• Accompanying all equipment and protective systems with instructions• Analysis of hazards arising from different ignition sources• Due analysis of equipment and protective systems• Marking all equipment and protective systems• Precise selection of electrically conductive materials• Filing a Declaration of Conformity with the notified body• Including the ATEX Declaration of Conformity with the packaging and shipment of every Versa-Matic ATEX Compliant pump
Versa-matic’s self-declared use of the ATEX mark and the documentation we provide is our published guarantee of compliance with the requirements of the directive and the safety of our products.
Versa-Matic self-declares complianceVersa-Matic self-declares compliance with the safety requirements accordingwith the safety requirements according to Annex VIII of EU Directive 94/9/EC.to Annex VIII of EU Directive 94/9/EC.
vmATEXbro-rev0914
VERSA-MATIC®
Warren Rupp, Inc.A Unit of IDEX Corporation800 North Main Street Mansfield, OH 44902 USA
Phone: 419.526.7296Fax: 419.526.7289www.versamatic.com
Distributed By:
© Copyright 2014 Warren Rupp, Inc. All Rights Reserved.
Versa-Matic delivers the safety of ATEX Compliance, in theVersa-Matic delivers the safety of ATEX Compliance, in the pump pump styles and materials the world demands.styles and materials the world demands.
AL = Aluminum CP = Conductive Polypropylene CI = Cast Iron P = Polypropylene SS = Stainless Steel K = PVDF H = Alloy C G = Conductive Acetal
Wilden® is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company.
ATEX COMPLIANTI M2 cII 3/2 GD c T5–Metallic II 3/2 GD c T6–Non-Metallic
Dimensionally interchangeable with Wilden® Metallic clamp style pumps.
=
SIZE MODELS MAX FLOW Metallic MaterialsAL CI SS H
Clamped Metallic Pumps1½" E4 71 gpm (268 lpm)2" E2 185 gpm (700 lpm)3" E3 234 gpm (886 lpm)
Bolted Metallic Pumps½"a E5 12 gpm (45 lpm)¾" E7 12 gpm (45 lpm)1" E1 49 gpm (185 lpm)
1½" E4 72 gpm (273 lpm)1½" E40 123 gpm (466 lpm)2" E2 160 gpm (606 lpm)3" E3 273 gpm (1,033 lpm)
FDA Food Processing Pumps½" E5 12 gpm (45 lpm)1" E1 49 gpm (181 lpm)
1½" E4 71 gpm (268 lpm)2" E2 185 gpm (700 lpm)3" E3 234 gpm (886 lpm)
Sanitary Pumps1½" E4 86 gpm (326 lpm)2" E2 180 gpm (681 lpm)
Flap Valve Pumps2" E2 219 gpm (829 lpm)
High Pressure Pumps (2:1)1" N25 30 gpm (114 lpm)2" N50 90 gpm (341 lpm)2" E2 69 gpm (261 lpm)
Non-Metallic Pumps Non-Metallic MaterialsCP P K G
¼" E6 4 gpm (15 lpm)½" E5 11 gpm (42 lpm)1" E1 45 gpm (170 lpm)
1½" E4 72 gpm (273 lpm)