astm international committee releases latest room ... · positive displacement pumping solutions...

6
PUMPSANDSYSTEMS.COM 53 The American Society for Testing and Materials (ASTM) International Committee F03 on Gaskets recently released the latest standard practice to derive gasket design constants for the proper design of bolted flanged joints (BFJs): ASTM F2836-18. End users of gaskets can then use these gasket constants for proper BFJ design using calculation methods that are currently being developed by a special working group of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) Section VIII at the time of this publication. In this article, the current test procedure, the mathematical models of the test evaluation and the calculation of the characteristics are described and discussed. Background Most industry professionals are aware that BFJs used in fluid service are complex mechanical systems. In order to create a high-performing BFJ, a designer needs to carefully consider not only the service conditions the BFJ will encounter, but also the performance characteristics inherent to the components of the BFJ. The gasket itself is one of these critical, yet often overlooked, components, and efforts to determine and quantify the performance characteristics of gaskets have been ongoing for decades. The newest of these efforts to be published in the United States is ASTM F2836-18: Standard Practice for Gasket Constants for Bolted Joint Design (commonly referred to as the Room Temperature Tightness Test, or ROTT). The design constants produced by this method enable a more robust design of BFJs compared to previous, antiquated design constants, such as the m and y factors. The crucial gasket constants produced by this standard practice are a, G b and G s . These constants effectively describe the tightness behavior of the gasket material, reflective of different loading and service conditions. In addition to their application to the ASME calculation method currently under development, the constants can also be ASTM International Commiee Releases Latest Room Temperature Tightness Test There is a new method to derive gasket design constants for bolted joint design. ADAM ARNETT | FSA Member IMAGE 1: Example of a servo-hydraulic test stand (Images courtesy of Amtec North America, Inc.) SEALING SENSE Test Step Test Part Stress Level Gasket Stress Sg [Mpa] Fluid Pressure P [MPa] 1 A S1 8 6 2 A S2 20 6 3 A S3 30 6 4 A, B1 S4 40 6 5 B1 S1 8 6 6 A, B1 S5 50 6 7 A, B2 S6 60 6 8 B2 S2 20 6 9 B2 S1 8 6 10 A, B2 S7 70 6 11 A, B3 S8 80 6 12 B3 S3 30 6 13 B3 S1 8 6 14 A, B3 S9 90 6 15 A, B4 S10 105 6 16 B4 S4 40 6 17 B4 S1 8 6 18 A, B4 S11 120 6 19 A S12 140 6 20 A, B5 S13 160 6 21 B5 S5 50 6 22 B5 S1 8 6 IMAGE 2: High-pressure test sequence

Upload: others

Post on 16-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ASTM International Committee Releases Latest Room ... · POSITIVE DISPLACEMENT PUMPING SOLUTIONS 2020 Cat Pumps 20051 2/20 For over 50 years, equipment manufacturers and contractors

PUMPSANDSYSTEMS.COM 53

The American Society for Testing and Materials (ASTM) International Committee F03 on Gaskets recently released the latest standard practice to derive gasket design constants for the proper design of bolted flanged joints (BFJs): ASTM F2836-18. End users of gaskets can then use these gasket constants for proper BFJ design using calculation methods that are currently being developed by a special working group of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) Section VIII at the time of this publication. In this article, the current test procedure, the mathematical models of the test evaluation and the calculation of the characteristics are described and discussed. BackgroundMost industry professionals are aware that BFJs used in fluid service are complex

mechanical systems. In order to create a high-performing BFJ, a designer needs to carefully consider not only the service conditions the BFJ will encounter, but also the performance characteristics inherent to the components of the BFJ. The gasket itself is one of these critical, yet often overlooked, components, and efforts to determine and quantify the performance characteristics of gaskets have been ongoing for decades.

The newest of these efforts to be published in the United States is ASTM F2836-18: Standard Practice for Gasket Constants for Bolted Joint Design (commonly referred to as the Room Temperature Tightness Test, or ROTT). The design constants produced by this method enable a more robust design of BFJs compared to previous, antiquated design constants, such as the m and y factors.

The crucial gasket constants produced by this standard practice are a, Gb and Gs. These constants effectively describe the tightness behavior of the gasket material, reflective of different loading and service conditions.

In addition to their application to the ASME calculation method currently under development, the constants can also be

ASTM International Committee Releases Latest Room Temperature Tightness Test There is a new method to derive gasket design constants for bolted joint design.

ADAM ARNETT | FSA Member

IMAGE 1: Example of a servo-hydraulic test stand (Images courtesy of Amtec North America, Inc.)

SEALING SENSE

Test Step

Test Part

Stress Level

GasketStress

Sg [Mpa]

FluidPressureP [MPa]

1 A S1 8 6

2 A S2 20 6

3 A S3 30 6

4 A, B1 S4 40 6

5 B1 S1 8 6

6 A, B1 S5 50 6

7 A, B2 S6 60 6

8 B2 S2 20 6

9 B2 S1 8 6

10 A, B2 S7 70 6

11 A, B3 S8 80 6

12 B3 S3 30 6

13 B3 S1 8 6

14 A, B3 S9 90 6

15 A, B4 S10 105 6

16 B4 S4 40 6

17 B4 S1 8 6

18 A, B4 S11 120 6

19 A S12 140 6

20 A, B5 S13 160 6

21 B5 S5 50 6

22 B5 S1 8 6

IMAGE 2: High-pressure test sequence

Page 2: ASTM International Committee Releases Latest Room ... · POSITIVE DISPLACEMENT PUMPING SOLUTIONS 2020 Cat Pumps 20051 2/20 For over 50 years, equipment manufacturers and contractors

54 PUMPS & SYSTEMS MARCH 2020

SEALING SENSE

used to compare materials so the proper one may be selected for the application.

Who Will Use ASTM F2836-18?ASTM F2836-18 is a helium leakage testing and evaluation method that determines tightness-based design constants at

room temperature for pressurized bolted flange connections that are designed in accordance with ASME BPVC. As such, ROTT applies mainly to all types of circular gasket products—including, but not limited to, sheet-type, spiral wound, solid metal and jacketed gaskets.

IMAGE 5: Log plot of stress versus leakage for all high- and low-pressure tests

IMAGE 4: Validity check rules

Validity Check Rules

Stress level, Sg Leak Rate Level, Lrm

RatioRLM=Lrm/Lrm

S1 0.2 < RLM < 5

Lrm > 10E-2mg/s 0.33 < RLM < 3

10E-2 mg/s > Lrm > 10E-5 mg/s

0.25 < RLM < 4

10E-2 mg/s > Lrm > 10E-8 mg/s

0.25 < RLM < 5

Test Step

Test Part

Stress Level

GasketStress

Sg [Mpa]

FluidPressureP [MPa]

1 A S1 8 2

1a A S2 20 2

2 A S3 30 2

3 A S5 50 2

4 A S7 70 2

5 A S10 105 2

6 A S12 140 2

IMAGE 3: LP test sequence

Pump Systems Assessment Professional

Set yourself and your organization apart with training and certi�cation that provides professionals with the knowledge and tools to engage and serve customers while providing clients with a higher level of con�dence in your skills and ability.

Stand Out Amongst Your PeersValidate your expertise through the certi�cation process

Elevate Your Reputation & MarketabilityGet listed on the HI website with other certi�ed professionals

Increase the Value of Your ServicesDemonstrate your commitment to energy e�ciency and reliability

Pump Systems Matter™, the educational branch of the Hydraulic Institute, is o�ering a 2 ½ day training course on pump and pump system fundamentals, system optimization and assessment, and preparation for the rigorous Pump System Assessment Professional certi�cation exam. If you would like to host a training course and certi�cation exam at your location or have any questions regarding training, please contact us at [email protected]

Complete details and registration can be found at pumps.org/PSAPtraining

PUMP SYSTEM TRAINING course

Check 112 on index.

Page 3: ASTM International Committee Releases Latest Room ... · POSITIVE DISPLACEMENT PUMPING SOLUTIONS 2020 Cat Pumps 20051 2/20 For over 50 years, equipment manufacturers and contractors

PUMPSANDSYSTEMS.COM 55

StepMPa

S18

S220

S330

S440

S550

S660

S770

S880

S990

S10105

S11120

S12140

S13160

1 X X X X X X X

2 X X X X X X X X

3 X X X X X X X X X

4 X X X X X X X X X

5 X X X X X X X X X

6 X X X X X X X X X X

7 X X X X X X X X X X X X X

8 X X X X X X X X X X X X

9 X X X X X X X X X X X

10 X X X X X X X X X X

11 X X X X X X X X X

12 X X X X X X X X

13 X X X X X X X

14 X X X X X X

15 X X X X X X

16 X X X X X

17 X X X X X

18 X X X X

19 X X X X

20 X X X

21 X X

Data

Set

s

Check 132 on index.

IMAGE 6: Possible Part A data sets for evaluation

Page 4: ASTM International Committee Releases Latest Room ... · POSITIVE DISPLACEMENT PUMPING SOLUTIONS 2020 Cat Pumps 20051 2/20 For over 50 years, equipment manufacturers and contractors

56 PUMPS & SYSTEMS MARCH 2020

SEALING SENSE

As such, these constants stand to be of interest to all parties who work with circular gaskets and have a vested interest in producing a high-performing BFJ, including end users, BFJ assembly contractors and gasket manufacturers.

Testing ProcedureThe test method consists of analyzing data from multiple gasket leakage tests in order to calculate the three aforementioned design constants for a particular model and size of gasket. The testing can be performed in a pair of appropriately sized flanges, using bolts to achieve varying gasket loads, or in a servo-hydraulic test stand of adequate capacity (Image 1).

In total, the procedure consists of two high-pressure (HP) tests at 6 megapascal (MPa) (870 pounds per square inch [psi]) of helium and two low-pressure (LP) tests at 2 MPa (290 psi) of helium, for a total of four tests on four different specimens. In addition to the differences in internal pressure, the HP and LP tests are also distinct from each other in terms of the gasket loading sequences.

The HP test consists of loading and unloading sequences, continually introducing successively higher loads onto the gasket while interrupting this loading sequence with intermittent unloading ramps. The LP test consists of only a loading sequence.

In both tests, the helium leak rate is measured at these various gasket loads.

For the purposes of test evaluation and gasket constant derivation, the different loading sequences of the tests are categorized as either Part A or Part B. Part A consists of the loading sequences, while Part B consists of the unloading sequences. Therefore, the HP test contains both Part A and Part B sequences, while the LP test consists of Part A only.

See Image 2 and Image 3 for details of the HP and LP testing sequences, respectively.

With its increasing gasket loads, Part A simulates assembly of the gasket in the joint, and therefore represents the gasket seating process. The data from this portion of the test is used to determine the required seating load for the gasket to create a tight seal.

Part B simulates the operating conditions by unloading the specimen to different gasket stress levels. This replicates unloading of the gasket, seen in real applications, due to

Check 141 on index.

Vibration Meterfor use in potentially explosive environments

800-368-5719 testproductsintl.com/9080-ex

Detect/Predict: Bearing Failure, Unbalance, Misalignment & LoosenessAsset management & trending, with included VibTrend Software.

9080-Ex: $3,995.00TPI 9080 Vibration Analyzer, (NOT Intrinsically Safe), $995.00

Easily and affordably detect or predict pump or machinerybreakdown in hazardous areas with the:

Intrinsically SafeTPI 9080-ExClass 1, Div 2. IEC Ex/ATEX

Ex ib IIC T4 Gb

Check 146 on index.

THE EXPERT SEARCH TEAMHGI is a Forbes Rated, Professional & Executive Search Firmwith proven success helping Pump & Process Equipmentproviders in virtually every market sector attract new energy,thinking and leadership.

We deliver:✔ Pump industry veteran-led search team.✔ The resources of a 40+ member search firm.✔ Customized strategy and pricing.✔ Experience placing talent at every level and function.✔ Every project taken on as a team.

Jack Stuhlreyer30 years in management with Pump & ProcessEquipment manufacturers, now 10 years with HGI404.781.3131 (Atlanta Office)602.314.8337 (Scottsdale Office)[email protected]

Most industry professionals are aware that BFJs used in fluid service

are complex mechanical systems.

Page 5: ASTM International Committee Releases Latest Room ... · POSITIVE DISPLACEMENT PUMPING SOLUTIONS 2020 Cat Pumps 20051 2/20 For over 50 years, equipment manufacturers and contractors

PUMPSANDSYSTEMS.COM 57

various factors including internal pressure and relaxation effects of a gasket during operation. Part B test data is used to determine the required operating gasket load in order to maintain a tight seal.

Results Analysis & Gasket Characteristic CalculationAfter the four tests (two HP tests and two LP tests) have been completed, a verification procedure—known as a validity check—must be performed to check whether the measured helium leakage at individual gasket stresses demonstrates satisfactory repeatability within the high-pressure and low-pressure test pairs. The leakage (expressed in milligrams/second [mg/s] of helium) of corresponding steps in the high-pressure and low-pressure tests are directly compared by dividing the leak rate of the first test of the pair (Lrm1) by the leak rate of the second test of the pair (Lrm2) to produce a ratio: RLM. The data is considered validated if the value of RLM falls within the bands described in Image 4 for each corresponding test step.

Once acceptable repeatability between the test pairs is realized, the gasket constants a, Gb and Gs may be calculated. The source of these values can be visualized on a combined plot of gasket stress versus the tightness parameter (an expression of leakage, see Equation 1) on log scales for all four tests (Image 5).

Gb and a are characteristics of the regression of the Part A data set that delivers the highest value of R2 (least square method).

POSITIVE DISPLACEMENT PUMPING SOLUTIONS

© 2020 Cat Pumps 20051 2/20

For over 50 years, equipment manufacturers and contractors have trusted Cat Pumps to keep their systems running. With the longest-lasting products backed, with the best delivery and customer service in the industry, Cat Pumps has a solution for all of your high-pressure pumping needs.

A Wide Range of Pressure and Flow:• 100 to 10,000 psi (6.9 to 689 bar)• 0.13 to 240 gpm (0.49 to 908 lpm)

(763)780-5440 • [email protected]

Pumps fitted with GRAPHALLOY® wear parts survive upsets.

+1.914.968.8400 • www.GRAPHALLOY.comYonkers, NY USA

GRAPHITE METALLIZINGCORPORATION

• Self-lubricating• Non-galling• Won’t swell• Corrosion resistant• Dimensionally stable• Improved efficiencies• -400˚F to 1000˚F (-240˚C to 535˚C)

Thousands of PumpsHave Never Seized

Thousands of PumpsHave Never Seized

P1

Check 133 on index.

Check 134 on index.

Where:P = Fluid pressure (MPa), P* = reference pressure

(0.1013 MPa), Lrm = mass leak rate (mg/s)

of ROTT gasket specimens dimension;

Lrm* = unit mass leak rate (1 mg/s for a 150 mm gasket OD)

Equation 1

Page 6: ASTM International Committee Releases Latest Room ... · POSITIVE DISPLACEMENT PUMPING SOLUTIONS 2020 Cat Pumps 20051 2/20 For over 50 years, equipment manufacturers and contractors

58 PUMPS & SYSTEMS MARCH 2020

SEALING SENSE

There are 21 possible sets of Part A data defined by the standard that must be evaluated (Image 6).

After the data set whose regression returns of the highest value of R2, Gb is found as the intercept of this regression line at Tp = 1, while a is the slope of this line (Image 5).

The determination of the unloading constant Gs is more straightforward compared to the other two constants. Gs is defined as the stress intercept at Tp = 1 associated with the regressions of each unloading sequence of the Part B data set (Image 5).

The standard practice ASTM F2836-18, or ROTT, is the newest publication by a standardization body in the U.S. aimed at producing gasket constants to be used in the design of gasketed BFJs. The loading and unloading gasket stress sequences, combined with leakage testing at different internal pressures, create gasket constants that can characterize a gasket’s performance over a broad range of installation and service conditions.

Industry is already demanding these constants for gasket products while awaiting the publication of the design equations as determined by the ASME BPVC Section VIII Special Working Group.

We invite your suggestions for article topics as well as questions on sealing issues

so we can better respond to the needs of the industry. Please direct your suggestions and questions to [email protected].

Adam Arnett is engineering project manager at amtec North America, where he is responsible for testing and analysis projects of fluid sealing technologies according to industry standards and custom investigation and testing projects. He earned a Bachelor of Science in mechanical engineering from Ohio University. For more information, visit amtec-services.com.

PUMPS &SYSTEMSa live training event

101

pumpsandsystems.com/eventregister

EARN CEUsCertificate of Completion provided for each class attended.

JIM ELSEY Pumps & Systems columnistFeatured Trainer

TOPICS INCLUDING:• Understanding NPSH• Reading a Pump Curve• Preventing Motor Failure• Centrifugal vs. Positive Displacement

Pumps

chicagoapril 23

Contact [email protected] if you have 3 or more attendees.

1-800-962-4851helwigcarbon.com

You can extend the life of your motors and prevent costly damage to bearings!

P U M P M O T O RBEARINGPROTECTION

• Reduce downtime

• Save money

• Easy installation

• Superior performance

Check 137 on index.

Next month’s “Sealing Sense” article will look at dry running mechanical seal faces.

A Look Ahead...