HOW TO USE THIS MANUAL

COPYRIGHT

SLC BV 1997. All rights reserved. No part of this publication may be reproduced, transmitted, stored in a retrieval system, ortransmitted in any form, or by any means - electronic, photocopying, recording, or otherwise - without the prior written permissionof SLC BV.

DISCLAIMER

SLC BV makes no representations or warranties with respect to the contents hereof and specifically disclaim any impliedwarranties of merchantability or fitness for any particular purpose. Further SLC BV reserve the right to revise this publication andto make changes from time to time in the contents hereof without the obligation of SLC BV to notify any person of any suchrevision.

Page 3: Aritech CD7212 Install

Installation manual for CD72/95/15012 Page 3

This manual contains installation details for the CD72, CD95 and CD150. When used in conjunction with theProgramming Manual and the User Manual, it provides the installation engineer with basic installation andprogramming information.

Programming

The 'Programming Manual' for the CD72 or the CD95/CD150 covers all necessary aspects of programmingthe system. Everybody involved in installing or maintaining this panel should have access to a copy of thismanual. The 'Programming Manual’ is available from your ARITECH national office.

The ‘Programming Map’ for the various systems can be found at the end of this manual.

Page 4: Aritech CD7212 Install

Page 4 Installation manual for CD72/95/15012

Page 5: Aritech CD7212 Install

Installation manual for CD72/95/15012 Page 5

CONTENTS

INSTALLATION GUIDELINES ..................................................................................................... 7

Before switching on the power..................................................................................................... 8Figure 1. Separate alarm and tamper connection ............................................................... 8Figure 2. Joint Connecting the alarm & tamper ................................................................... 8Figure 3. Overview of the dipswitches on remotes.............................................................. 9

PROGRAMMING GUIDE.......................................................................................................... 11Figure 4. Keys on a CD30xx.............................................................................................. 11

Returning to default settings...................................................................................................... 12

Leaving programming mode...................................................................................................... 13

Dialler ........................................................................................................................................ 13

Other manuals........................................................................................................................... 13

INSTALLATION GUIDE ........................................................................................................... 14

Wiring diagrams CD72 .............................................................................................................. 14Figure 5. CD72 cabinet...................................................................................................... 14Figure 6. CD72 control panel............................................................................................. 15

Wiring diagrams CD95/150 ....................................................................................................... 16Figure 7. CD95 cabinet...................................................................................................... 16Figure 8. CD150 cabinet.................................................................................................... 16Figure 9. CD95/150 control panel...................................................................................... 17

Opening CD3008 / CD3048 keypad .......................................................................................... 18Figure 10. Opening the CD3008 / CD3048 keypad.......................................................... 18

Opening CD3009 / CD3049 keypad .......................................................................................... 18Figure 11. Opening the CD3009 / CD3049 keypad........................................................... 18

CD3008 / CD3009 keypad......................................................................................................... 19Figure 12. CD3008 / CD3009 keypad ............................................................................... 19

CD3048 / CD3049 keypad......................................................................................................... 19Figure 13. CD3048 / CD3049 keypad ............................................................................... 19

CD9031 expander ..................................................................................................................... 20Figure 14. CD9031 expander ............................................................................................ 20

Keypad back tamper ................................................................................................................. 21

Connecting an extra power supply............................................................................................. 22Figure 15. Use of an extra power supply........................................................................... 22

Inputs ........................................................................................................................................ 22

Connecting a detector without memory ..................................................................................... 23Figure 16. Dual loop Connecting a detector without memory............................................ 23

Connecting a detector with Latch .............................................................................................. 23Figure 17. Dual loop Connecting a detector with latch ...................................................... 23

Connecting a key switch............................................................................................................ 24Figure 18. Connecting a key switch with LED's................................................................. 24

Connecting a “nitewatch” system............................................................................................... 24Figure 19. Connecting a CP4005 Nitewatch PCB............................................................. 24

Page 6: Aritech CD7212 Install

Page 6 Installation manual for CD72/95/15012

Connecting a fire detector ......................................................................................................... 25Figure 20. Connecting a fire detector ................................................................................ 25

Outputs ..................................................................................................................................... 26

Connecting a relay or an LED.................................................................................................... 26Figure 21. Connecting a relay or an LED on the output .................................................... 26

Connecting an AS256 and AS294/394 sounder ........................................................................ 27Figure 22. Connecting the AS294/394 + internal siren AS256.......................................... 27Figure 23. Connecting the AS294/394 .............................................................................. 27

Connecting the GS600/610/710/711 shock sensor (CD72 only)................................................ 28Figure 24. Connecting the GS710/711 with separate alarm & tamper loops .................... 28Figure 25. Connecting the GS710/711 with combined alarm & tamper loops................... 28

Printer output............................................................................................................................. 29Figure 26. Printer connection ............................................................................................ 29

AS270/AS271 internal siren....................................................................................................... 30

SPECIFICATIONS .................................................................................................................. 31

PROGRAMMING MAP CD7212 .............................................................................................. 33

PROGRAMMING MAP CD95/15012 ....................................................................................... 37

Page 7: Aritech CD7212 Install

Installation manual for CD72/95/15012 Page 7

INSTALLATION GUIDELINES

The CD72, CD95/150 control panels have been designed, assembled and tested to meet current standardsof stability and resistance to electrical interference from the environment.

If the following guidelines are followed, the system should give many years of reliable service.

1. Ensure that there is a good earth for the alarm system.

A GOOD EARTH IS ESSENTIAL FOR EFFECTIVE RESISTANCE TO ELECTRICALINTERFERENCE

Do not forget to provide a (network) earth for the telephone dialler.

2. Maintain a good separation between low voltage and mains supply cables, and use separate points ofentry into the control panel cabinet.

3. Avoid loops of wire inside the control panel and route cables so they do not lay on top or underneaththe printed circuit board. The use of cable ties is recommended and improves neatness in the box.

4. Mains switching relays must NOT be fitted inside the control panel cabinet. The switching of theserelays may cause electrical interference.

4.1 Use a relay with good insulation between the contacts and the coil.

4.2 Place a suppression diode (e.g. a 1N4001) across the relay coil.

4.3 Relays connected to open collector outputs of the alarm system should be rated at 12 volts DCwith a coil impedance greater than 400 Ohms.

5. The remote bus cable is used for communication between the control panel and thekeypads/expanders. The greatest care should therefore be taken when installing this cable. NEVERsplit this cable into separate cables. Do not use cables with wires which are used for TELEPHONEconnections or for switching, for example, flashing lights, sirens or relays.

6. Avoid cable ducts and cable ways which contain mains power cables. This is particularly importantwhen such ducts contain cables supplying electric motors, fluorescent lights or 3-phase power. If this isnot possible, shielded cable should be used and the cable should be earthed at the control panel endONLY.

Page 8: Aritech CD7212 Install

Page 8 Installation manual for CD72/95/15012

BEFORE SWITCHING ON THE POWER

1. Detectors (or key switches) can be connected in two ways:

Conventional: One zone each is required for both tamper and the alarm. Both zones should beclosed with an end-loop resistor (4.7 kOhm). Program the ‘zones’ menu as ‘Alarm’

Figure 1. Separate alarm and tamper connection

Dual loop: The alarm and tamper are placed together in one zone. The zone has two end-loopresistors (4.7 kOhm) to differentiate between alarm and tamper. Figure 2 shows howthey are connected. Program the ‘zones’ menu as ‘Dual’.

Figure 2. Joint Connecting the alarm & tamper

This connection method gives the following input values:

The zone is Resistance Panel zonevoltages

Remote zonevoltages

Reaction

on standby 3k5 - 6k2 2.1 - 2.8 V 4.7 - 6.8 V none

triggered 6k6 - 11k7 2.9 - 3.6 V 6.9 - 8.6 V alarm

open > 12k7 > 3.7 V > 8.7 V tamper

short-circuited < 2k9 < 1.9 V < 4.6 V tamper

Table 1. Operation of the inputs

Page 9: Aritech CD7212 Install

Installation manual for CD72/95/15012 Page 9

2. Set the DIP switches of all the remote keypads and expanders.Remote 1 must be a keypad.CD72, remotes 2 to 4 must be keypads and remotes 5 and 6 expanders.CD95/150, remotes 2 to 8 can be keypads or expanders but remotes 9 to 16 must be expanders.

1 2 3 4

ON SD

Keypad 1

Keypad 1(all off)

1 2 3 4

ON SD

Remote 2

Keypad 2

1 2 3 4

ON SD

Remote 3

Keypad 3

1 2 3 4

ON SD

Remote 4

Keypad 4

CD95/150

CD72

1 2 3 4

ON SD

Remote 5

Expander 1

1 2 3 4

ON SD

Remote 6

Expander 2

1 2 3 4

ON SD

Remote 7

1 2 3 4

ON SD

Remote 8CD95/150

CD72

1 2 3 4

ON SD

Expander 9

1 2 3 4

ON SD

Expander 10

1 2 3 4

ON SD

Expander 11

1 2 3 4

ON SD

Expander 12CD95/150only

1 2 3 4

ON SD

Expander 13

1 2 3 4

ON SD

Expander 14

1 2 3 4

ON SD

Expander 15

1 2 3 4

ON SD

Expander 16CD95/150only

Figure 3. Overview of the dipswitches on remotes

3. Close the tamper switches on the remote keypads, expanders and the control panel. Also close allzones which can cause a direct alarm. If this is not done, the system will be triggered as soon as it isswitched on.

4. Remove link LK1 or JP1 from the PCB so that it returns to default settings.

Page 10: Aritech CD7212 Install

Page 10 Installation manual for CD72/95/15012

5. Supply only mains power to the control panel. The system will power up in the ARMED state. Anyzones that may be open will initiate a full alarm condition and the sounders will activate.

Do not use a battery to power the system when installing or changing the installation. If there is ashort circuit in the 12 volt power supply, the voltage regulators in the supply (together with the fuses)will prevent serious damage to the system The 12 volt power supply will decrease sharply in theevent of a short circuit.

If a short circuit should occur, remove the 12 volt connections one by one. When the connection withthe short circuit is removed the power supply will return to 12 volts.

NOTE: ONLY KEYPAD ONE IS OPERATIONAL.

Every time power is removed from the system the control panel memorises its status. If power isrestored to the panel, the system starts up again in this status (except if LK1/JP1 has been removed).

6. Enter ‘0’ followed by the default user code ‘1122’ at keypad 1. 'Disarm?’ is shown on the display.System then disarms.

If the sirens have been activated, these will now stop. The status of the system or the time and datewill now appear in the display.

7. Enter ‘0’ followed by the default engineer’s code ‘1278’ at keypad 1 and press ‘ââ’ to return toprogramming mode.

N.B. Do not forget to initialise additional keypads and expanders with the menu:‘INSTALL REMOTE’

Replace LK1/JP1.

Page 11: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 11

PROGRAMMING GUIDE

1. Take some time to become familiar with the overview of the programming maps which can be foundat the end of this manual.

2. Any programming changes made may not take effect until you exit programming mode.

3. If while programming an option the message “No Privilege” is displayed, the configuration is “SplitSystem” and you do not have access to all the areas. This may be caused by not obtaining “ExtendedAccess” (Maintenance menu), or because one or more of the areas are armed.

4. The following keys may be used:

Always enter a ‘0’ before entering anengineer/user code to prevent errors !

Under keys 1 to 9 there are 3 letters of thealphabet: press the keys repeatedly to enter firstthe number, then the lower case letters and thenthe upper case letters. Keys 9 and 0 have specialsymbols such as the comma and space.The arrows move the cursor during entry.Press ‘üü’ to accept an entry.Cancel an entry by pressing ‘X’.

To delete a character, overwrite with anothercharacter or a space.

Note: CD30xx stands for the keypads:CD3008, CD3048, CD3009 and CD3049

DISPLAY

ABC

1

DEF

2

GHI

3

JKL

4

MNO

5

PQR

6

STU

7

VWX

8

YZ

9Cursor left

á 0

Cursor right

â down up

End

Accept

X

ü

Figure 4. Keys on a CD30xx

Page 12: Aritech CD7212 Install

Page 12 Installation manual for the CD72/95/15012

RETURNING TO DEFAULT SETTINGS

There are two methods of returning the system (not the dialler) to default settings, these are:

1. The removal of JP1 (CD72) or LK1 (CD95/150). Subject to the ‘Engineers Lock’ not beingprogrammed, this method will return the panel to default settings without the use of an engineer’scode. Proceed as follows:

- Remove both the battery and the mains power.

- Remove jumper JP1/LK1.

- Connect the mains power. Only keypad 1 is operational. The software version is displayed on theother keypads (if present). As the default setting is “armed” any open zones will trigger the systemand the sounders will activate.Enter ‘0’ followed by the default code ‘1122’ to disarm the system.Use code ‘1278’ to return to programming mode.If the default codes are invalid, the system had ‘Engineers Lock’ blocking programmed.If the current engineers’ code is known use procedure 2, if not, then replacement of the PCB isthe only way to gain access to programming mode.

2. By programming. Use this method if ‘Engineers Lock’ blocking is active and the engineers’ code isknown. Proceed as follows:

- KEYPAD ONE MUST BE USED FOR THIS PROCEDUREALL AREAS MUST BE DISARMED

- Go to keypad 1.

- Enter the installation engineers’ code.

- If the system is split, you will be asked for an area number, enter 1, press ‘↓↓‘ and you will enterthe ‘Maintenance’ section of the engineers programming menu.Accept this ‘üü’ and use the down arrow key until ‘Extended Access’ is displayed.Accept this ‘üü‘ to gain extended access, then press ‘X’ to return to ‘Maintenance’.

- Press ‘7’, ‘6’ and ‘1’ successively. You are now in the menu ‘Miscellaneous’, ‘Factory Prog.Menu’, ‘Default Settings’. ‘Are you sure?’ flashes in the display.If ‘No Privilege’ appears, there are two possibilities:

◊ You are not at keypad 1

◊ The system is split and you do not have access to all areas. Check this using ‘ExtendedAccess’.

- Press accept (‘üü’). ‘Wait ...’ appears in the display.

- The system has now reverted to default settings.

Page 13: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 13

LEAVING PROGRAMMING MODE

Before leaving programming mode use the ‘Show Open Zones’ facility under the ‘Maintenance’ menu (menu1.3). If any zones shown are 24Hr zones (e.g. tamper or fire) the alarm will activate on leaving the engineers’programming mode.

If dual loop is programmed, the letter T will appear next to the zone number to indicate the tamper section ofthe loop is open.

Procedure:

a. Check for open 24Hr zones (see above).b. Press ‘X’ until ‘Goodbye’ is displayed.c. Press accept ‘üü’.

DIALLER

The use of the RD6203 dialler is recommended. This dialler fits inside the control panel cabinet and isconnected to the control panel’s PCB using the cable supplied. The dialler may also be programmed via thekeypad.

A separate manual is available for the dialler.

OTHER MANUALS

Programming Manual CD72 orCD95/150

A fully documented programming information manual. Separateversions for the CD72 and the CD95/150

User manual Details user options

Manager Manual A user manual which examines the options in more depth.Intended for the manager.

Programming Manual RD6203 Documented information on programming the RD6203 dialler

Page 14: Aritech CD7212 Install

Page 14 Installation manual for the CD72/95/15012

INSTALLATION GUIDE

WIRING DIAGRAMS CD72

Power supplyadjustment (DONOT ADJUST)

Printer connector

Fixing hole

Fixing hole Fixing hole

Cable entries

BATTERY230V connection

Transformer

Main PCB

Main PCB

RD6203 Dialler

To hold lid in place whileservicing the panel

Figure 5. CD72 cabinet

Page 15: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 15

∼ ∼ − +1 2 3 4

78910111213

−+−+−+

1415161718192021

2223242526272829

3031323334

35363738

F1

F2

F3

F4

F5

F6

J1

DCBA

3940414243

12345

Battery18VAC

To RD6203

Eprom

Processor

EEprom

JP1

Tamperswitch

external tampering

Ext. SirenTamper

Line Fault

to keypads andexpanders

Outputs

PL1

RS232printer

External siren (O/put 19)

Internal siren (O/put 18)

Aux. power

CD7203

Zones

1

8

See sectionspecifications

See sectionspecifications

Figure 6. CD72 control panel

Page 16: Aritech CD7212 Install

Page 16 Installation manual for the CD72/95/15012

WIRING DIAGRAMS CD95/150

Power supply adjustment (DO NOT ADJUST)

LED“power on”

Fixing hole

Memory cardconnector

Dialler connector

Input expandersocket

Main PCB

Fixing hole

RD6203 Dialler

BATTERY

Fixing hole

Mains cableentry

Transformer

Cable entries

Output expandersocket

Fixing hole

Printer connectorRS232

Fold lid down(CD95)

Figure 7. CD95 cabinet

Power supply adjustment (DO NOT ADJUST)Fixing hole

Dialler connector

Memory cardselector

Dialler connector

Output expandersocket

Printer connectorRS232

Mains cableentry

Fuse holder

Transformer

Screw holes for cover

Wall fixing holes

Cable fixingpoints

BATTERY

RD6203Dialler

Main PCB

Lift upPull forward

Opening the cabinet

Unscrew the screws (2x) Remove earth connection

Figure 8. CD150 cabinet

Page 17: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 17

Output Expander

Output41 to 48

1718192021222324

2526272829303132

333435363738

F1

Battery18VAC

To RD6203

Eprom

LK1

TamperSwitch

(CD95 only)

external tamperingtampersiren

line fault (in)

to keypads and remotes

Printer RS232

External siren O/put 50

Internal siren O/put 49

CD9503/CD15003

Zones

1

16

910111213141516

12345678

FTC/Reset (in)

3940414243444546

Outputs

1

8

910111213141516

12345678

CP4003Input

Expander

4748495051525354555657585960

DCBA-+-+-+-+

Poweroutput

Connectormemory card

zone 144 to 152

F2

F3

F4

F5

F6

F7

F8

12345678CD9005

See sectionSpecifications

Figure 9. CD95/150 control panel

Page 18: Aritech CD7212 Install

Page 18 Installation manual for the CD72/95/15012

OPENING CD3008 / CD3048 KEYPAD

Figure 10. Opening the CD3008 / CD3048 keypad

OPENING CD3009 / CD3049 KEYPAD

Figure 11. Opening the CD3009 / CD3049 keypad

Push

Push clip in withscrewdriver andlift up cover

Remove screw ifinstalled

Lift up

Page 19: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 19

CD3008 / CD3009 KEYPAD

Display contrastadjustment

Keypad addresssetting switches Cable entry from

top

Fixing hole

Push the side clipto remove PCB

Cable entry fromback

Cable entry frombottom

Fixing hole

Fixing hole

Extra screw tosecure lid

1 2 3

4 5 6

7 8 9

0

D

CB

A

4-wire busconnection

Buzzer volume adjustment

Figure 12. CD3008 / CD3009 keypad

CD3048 / CD3049 KEYPAD

Display contrastadjustment

Keypad addresssetting switches Cable entry from

top

Fixing hole

Push side clip toremove PCB

Cable entry fromback

Cable entry frombottom

Fixing hole

Fixing hole

Extra screw tosecure lid

1 2 3

4 5 6

7 8 9

0

Four-wire busconnectionD

C

BA

Buzzer volume adjustmentBuzzer

2

1

4

3

OB

ONZones

-

+

Power connection

OFF

Jumper to cutoff Buzzer

Figure 13. CD3048 / CD3049 keypad

Remote Connection toconnections CD 72 CD 95/150

A 38 50B 37 49C 36 48D 35 47

Page 20: Aritech CD7212 Install

Page 20 Installation manual for the CD72/95/15012

CD9031 EXPANDER

Cable entry fromtop

Fixing hole

Fixing hole

Fixing hole

Fixing hole

Lid tamperwith lid tamper = Link 1-2

without lid tamper = Link 2-3Expander Addresssetting switches

Cable entry fromback

Cable entry frombottom

Reversetampering

Zones

Outputs Four-wire busconnection

Covertampering

Processor

AC BDOAOBTAM

1

2

3

4

5

6

7

8

Figure 14. CD9031 expander

Remote Connection toconnections CD 72 CD 95/150

A 38 50B 37 49C 36 48D 35 47

Page 21: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 21

KEYPAD BACK TAMPER

• CD30xx base �.• When the keypad lid is not used, remove the hinge-slot blanking pieces from the base �and place them

in the hinge-slot openings �.• For back tamper protection fix the screw through the hole into the wall �.

Page 22: Aritech CD7212 Install

Page 22 Installation manual for the CD72/95/15012

CONNECTING AN EXTRA POWER SUPPLY

An auxiliary power supply will be required if the voltage is too low as a result of large cable runs or thecurrent demand is in excess of the panels current supply rating.

To connect an extra power supply the ‘+’ of the panel must not be connected to the ‘+’ of the auxiliary powersupply. Also do not connect the ‘+’ of different auxiliary power supplies together. If the auxiliary power supplyis used to power a remote expander/keypad, connect the “+” of the four wire bus (“A”) to the “+” of theauxiliary power supply. A common reference is obtained by connecting together all power supplies “-”.

IMPORTANT: NEVER INTERCONNECT POSITIVES OF POWER SUPPLIES. ALWAYS INTERCONNECT NEGATIVES OF

POWER SUPPLIES

A B C D-+

4-wire bus

Centralpowersupply

A B C D

4-wire bus ofkeypad orexpander

-

+

+ -41

D E

BU4

4K7 4K7

To “Power Monitor” zoneCD72/95/150

Auxiliary powersupply PG822

RC900

RC813

-+

Detector,siren, relay,

etc...

Detects failure ofthe mains power

Figure 15. Use of an extra power supply

INPUTS

Panel CD72 PanelCD95/150

Expander socketCD95/150

Numbering 1....8 1....16 145....152

Keypad 1 Keypad 2 Keypad 3 Keypad 4 Expander 5 Expander 6

CD72 9....12 13....16 17....20 21....24 9....16 17....24

Keypad 1 Remote 2 Remote 3 Remote 4 Remote 5 Remote 6 Remote 7 Remote 8

CD95/150 17....20 25....32 33....40 41....48 49....56 57....64 65....72 73....80Remote 9 Remote10 Remote11 Remote12 Remote13 Remote14 Remote15 Remote16

CD95/150 81....88 89....96 97....104 105....112 113....120 121....128 129....136 137....144

Table 2. Numbering of the inputs

Note: In the CD72 the expanders have priority over the keypads !

Page 23: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 23

CONNECTING A DETECTOR WITHOUT MEMORY

Input zonePower supply

4k7 4k7

SSAA7654321

Figure 16. Dual loop Connecting a detector without memory

CONNECTING A DETECTOR WITH LATCH

Power supply Input zoneOutput “Latch” Output “Walk test”

M WSSAA

4k74k7

1 2 3 4 5 6 7 8 9 10

Figure 17. Dual loop Connecting a detector with latch

Note: Before connecting, the cable between terminal 2 and terminal 10 should be removed!

Page 24: Aritech CD7212 Install

Page 24 Installation manual for the CD72/95/15012

CONNECTING A KEY SWITCH

Input zone “key”Key switch

C

NO

NC

C

NC

Tamper

+12V

Output“Arm/Disarm”

Output“System Clear”

4k7

4k7

“Programme outputs for negative applied”

Figure 18. Connecting a key switch with LED's

CONNECTING A “NITEWATCH” SYSTEM

CP 4005Light zone 1 /Light zone 2 /Daylight zone

Input zone4K7

4K7

Figure 19. Connecting a CP4005 Nitewatch PCB

Page 25: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 25

CONNECTING A FIRE DETECTOR

+O1-

1

5 2

16

NC

CD72/95/150

DB822+

DP803

NOC

4K7 4K7

To “fire” zone

2 3 4 5

RC213

4 1

23

7

DB602+

DP611/DI612/DT613

98

4K7 4K7

To “fire” zone

1 2 3 4 5

RC213

+O3O2

To sirencontrol (Sc)

This extra connection isonly necessary if acontinuous signal fromthe external siren isrequired

To terminal “5”of the RC213

relay.

OR

To “+”terminal ofthe panel

O1 = “Fire reset -”O2 = “External siren”O3 = “Fire -”

Figure 20. Connecting a fire detector

Note 1: If there are several detectors place them in parallel and cable the zones as described infigure 1 or 2 (see page 8).

Note 2: This connection also applied for detectors which require a reset after an alarm, e.g. theGS900 etc.

Note 3: The reset is performed after the second entry of a code after an alarm.

Note 4: Programme zone loop as “Dual”.

Note 5: Programme all outputs for negative applied “-”.

Page 26: Aritech CD7212 Install

Page 26 Installation manual for the CD72/95/15012

OUTPUTS

Panel Internal siren External siren Output expander

CD72 1....5 18 19

CD95/150 1....8 49 50 41....48

Keypad 1 Remote 2 Remote 3 Remote 4 Remote 5 Remote 6 Remote 7 Remote 8

OA OB OA OB OA OB OA OB OA OB OA OB OA OB OA OB

CD72 6 7 8 9 10 11 12 13 14 15 16 17

CD95/150 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Remote 9 Remote10 Remote11 Remote12 Remote13 Remote14 Remote15 Remote16

OA OB OA OB OA OB OA OB OA OB OA OB OA OB OA OB

CD150 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Table 3. Numbering of the outputs

NB: In a keypad OA is the buzzer. OB does not exist in a CD3008 / CD3009 keypad.

CONNECTING A RELAY OR AN LED

Output

+12 VoltNC NO

C

+12 Volt

R = 820

Output

Figure 21. Connecting a relay or an LED on the output

The resistor R is necessary to adjust the current. This may not be greater than 40 mA. For most LEDs,however, a current of approximately 15 mA is sufficient. The resistance calculation is as follows:

R VI

13,8V15 mA

13,8V 2V15mA

ledV787

When rounded off this is 820 Ohms.

Page 27: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 27

CONNECTING AN AS256 AND AS294/394 SOUNDER

3235

3336

1152

1051

T T + - T T + - BcSc

3033

3134

857

1354

1253

3939

AS256 AS294 / AS394

4K7

CD72CD95/150

Figure 22. Connecting the AS294/394 + internal siren AS256

Programming CD72 CD95/150

Beacon control 01 Int Sir Sy + 01 Int Sir Sy +Internal siren control 18 Int Sir Sy - 49 Int Sir Sy -

External siren control 19 Ext Sir Sy + 50 Ext Sir Sy +

Table 4. Programming for the sirens

NB: If the tampers must be placed in separate zones, they can be connected according to figure 1 (1 end-loop resistor) or figure 2 (2 end-loop resistors) (see page 8).

Figure 23. Connecting the AS294/394

Cut these 2 jumpers fornegative Hold-Off.The other 2 jumpers forpositive Hold-Off.

Page 28: Aritech CD7212 Install

Page 28 Installation manual for the CD72/95/15012

CONNECTING THE GS600/610/710/711 SHOCK SENSOR (CD72 ONLY)

Figure 24. Connecting the GS710/711 with separate alarm & tamper loops

Figure 25. Connecting the GS710/711 with combined alarm & tamper loops

Page 29: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 29

PRINTER OUTPUT

PL1 (CD72)PL4 (CD95/150)

PL1 (CD72)PL4 (CD95/150)

DB25RS232

DB9RS232

Figure 26. Printer connection

Page 30: Aritech CD7212 Install

Page 30 Installation manual for the CD72/95/15012

AS270/AS271 INTERNAL SIREN

Note:

*) This fixing screw is used for pry-off tamper.**) Screw to close siren.

Connection:

1. Tamper2. Tamper3. + 12V4. - 0V Speaker5. - 0V Beacon

Programming in the panel:

Connection Programming Output PanelAS270/AS271 Description Output connection

CD72 1 Tamper terminal 302 Tamper terminal 313 + 12V terminal 114 - 0V Internal siren 18 Internal siren - terminal 105 - 0V Flash/Beacon 18 Internal siren - terminal 10

CD95/150 1 Tamper terminal 352 Tamper terminal 363 + 12V terminal 524 - 0V Internal siren 49 Internal siren - terminal 515 - 0V Flash/Beacon 49 Internal siren - terminal 51

Page 31: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 31

SPECIFICATIONS

FUSES

CD72 CD95/150

230 V fuse 315 mA 20x5

F1 Battery 2 A 20x5

F2 Auxiliary power 1 A 20x5

F3 Internal siren 1 A 20x5

F4 External siren 1 A 20x5

F5 Dialler 1 A 20x5

F6 Remotes 1 A 20x5

230 V fuse 315 mA 20x5

F1 Dialler 800 mA 20x5

F2 Output 8 800 mA 20x5

F3 Auxiliary power 1 A 20x5

F4 Battery 3,15 A 20x5

F5 External siren 800 mA 20x5

F6 Internal siren 800 mA 20x5

F7 Remotes 800 mA 20x5

F8 Expander output 800 mA 20x5

230 VAC

Battery

secondary fuse 315 mA

12 Vdc, 16 Ah maximum for CD 72

12 Vdc, 24 Ah maximum for CD 95/150

Max. currentconsumption

Power consumption

CD 72

CD 95/150

CD 3008/3009

CD 3048/3049

CD 9031

RD 6203

max. 1.0 A, including remotes, dialler and unit for CD72

max. 2.0 A, including remotes, dialler and unit for CD95/150

typ. max.

66 mA

117 mA

26 mA 52 mA

30 mA 55 mA

26 mA

45 mA 95 mA

End of line resistors 4k7, 2 %, 0.25W

1 resistor for Alarm loop

2 resistors for Dual loop

Data bus

A

B

C

D

+ 12V

GND

Data in (to panel)

Data out (from panel)

Distance for data bus Max 1500m.

Page 32: Aritech CD7212 Install

Page 32 Installation manual for the CD72/95/15012

Dimensions (l x b x h)

CD 3008/3048

CD 3009/3049

CD 9031

CD 72/95

CD 150

160 x 120 x 35 (3 mm ABS)

160 x 120 x 35 (3 mm ABS)

175 x 125 x 37 (3 mm polycarbonate)

315 x 385 x 88 (1,25 mm steel plate)

475 x 460 x 160 (1,25 mm steel plate)

Output no. Location Output connected max. Zone no.

1 to 5 control panel 100 mA 1 to 8

6 to 17 remotes 40 mA 9 to 24

18 internal siren CD72 1A n/a

19 external siren CD72 1A n/a

Table 5. Overview of the inputs and outputs on the CD72

Output no. Location Output connected max. Zone no.

1 to 8 control panel 100 mA (output 8 = 1 A) 1 to 16

9 to 40 remotes 40 mA 17 to 144

41 to 48 expanders 100 mA (output 48 = 1 A) 145 to 152

49 internal siren CD95/150 1A n/a

50 external siren CD95/150 1A n/a

Table 6. Overview of the inputs and outputs on the CD95/150

Page 33: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 33

PROGRAMMING MAP CD7212Note: The quick code numbers in front of each menu item (i.e. 2.4.4 to jump to ‘Digi Cutout’) are also the section heading numbers in the‘Menu Contents’ chapter of the programming manual, where the items are explained.

Page 34: Aritech CD7212 Install

Page 34 Installation manual for the CD72/95/15012

Page 35: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 35

Page 36: Aritech CD7212 Install

Page 36 Installation manual for the CD72/95/15012

Page 37: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 37

PROGRAMMING MAP CD95/15012Note: The quick code numbers in front of each menu item (i.e. 2.4.4 to jump to ‘Digi Cutout’) are also the section heading numbers inthe ‘Menu Contents’ chapter of the programming manual, where the items are explained.

Page 38: Aritech CD7212 Install

Page 38 Installation manual for the CD72/95/15012

Page 39: Aritech CD7212 Install

Installation manual for the CD72/95/15012 Page 39

Page 40: Aritech CD7212 Install

Page 40 Installation manual for the CD72/95/15012