arc tracking test 18 from nasa-std-6001
DESCRIPTION
Arc Tracking Test 18 from NASA-STD-6001. Purpose: Determine ability of wire insulation materials or constructions to resist arc tracking and access damage caused by initial arcing and restrike events - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Arc Tracking Test 18 from NASA-STD-6001](https://reader035.vdocuments.us/reader035/viewer/2022081512/56813b0e550346895da3b70d/html5/thumbnails/1.jpg)
May 2000 MAPTIS Presentation 1
SME initiative
Arc TrackingTest 18 from NASA-STD-6001
• Purpose: Determine ability of wire insulation materials or constructions to resist arc tracking and access damage caused by initial arcing and restrike events
• Phenomena whereby an arc between two or more wires, once initiated, will sustain itself through a conductive path provided by degradation of the insulation for a measurable length
![Page 2: Arc Tracking Test 18 from NASA-STD-6001](https://reader035.vdocuments.us/reader035/viewer/2022081512/56813b0e550346895da3b70d/html5/thumbnails/2.jpg)
May 2000 MAPTIS Presentation 2
SME initiative
Arc TrackingTest in Progress
• Typical Specimen– 7 wire bundle 46 cm in length
• Arc Initiation– Short circuit of conductor ends by dry
graphite powder• Test Conditions
– Worst-case environment– 5 kW, 400 Hz, 3-phase, 200 volt/ 50
amps RMS• Acceptance Criteria
– Wire configuration is resistant to arc tracking if it does not exhibit arc propagation on either initial or reapplication of power