aquatic research series 2010-03 measuring stream...

29
Ministry of Natural Resources A A A A A A A A Aq q q q qu u u u u ua a a a at t t t t t t t t t ti i i i i i i i ic c c c c c c c c c c c R R R R R R R R R R R R R R Re e e e e e e e e e e e e e e e e e e e e es s s s s s s s s s s s s se e e e e e e e e e e e e e ea a a a a a a a a a ar r r r r r r r r r r r r r rc c c c c c c c ch h h h h h h h h h h a a a a a a a a a a a a a an n n n n n n n n n n n n nd d d d d d d d d d d d d d d D D D D D D D De e e e e e e e e e ev v v v v v v ve e e e e e e e e e el l l l lo o o op p m m m me e e en n n nt t t S S S Se e ec c c c ct t t ti i i i io o o o o o o o o o o on n n n n n n n n n n A A A A A A A A A Aq q q q q q q q q u u u u u u u u u ua a a a a a a a at t t t t t t t ti i i i i i ic c c c c c c c c c c c R R R R R R R R R Re e e e e e e e e e e e e e e e e e e e e e e es s s s s s s s se e e e e ea a a a a ar r r r r r r r r r r r rc c c c c c c c c c ch h h h h h h h h h h h S S S S S S S Se e e e e e e e er r r r r ri i i i i ie e e es s 2 2 2 20 0 0 0 0 0 01 1 1 1 1 1 1 1 1 10 0 0 0 0 0 0- -0 0 03 3 3 3 3 M M M M M M M M M M M M Me e e e e e e e e ea a a a a a a a a a a as s s s s s s s s s su u u u u u u u u u u ur r r r r r r r r r ri i i i i i i i i in n n n n n n n n ng g g g g g g g g g g g S S S S St t t t tr re e e ea a a a a a am m m m m m m m m m T T T T T T T T T T T e e e e e e e e e e em m m m m m m m m m m mp p p p p p p p p p p p e e e e e e e e e e e er r r r r r r r r r r ra a a a a a a a a a at t t t t t t t t tu u u u u u u u u ur r r r r re e e e e e e e e e e U U U U U U U U U U U Us s s s s s s si i i i i i i i in n n n n n n n n n ng g g g g g g g D D D D D D D D D D D Da a a a a a a at t t t t t t t t t t t t t t t ta a a a a a a a a a a a a a L L L L L L L L L L L L L Lo o o o o o o o o o o o o o og g g g g g g g gg g g g g g g g g g e e e e e e e e e e e e e e e e e e er r r r r r r r rs s s s s s s s s s s s s s s s: : : : : : : : : : : : : : L L L L L L L L L L L L L L L L L L L L L L L L L L L L La a a a a a a a a a a a a a a a ab b b b b b b b b b b b bo o o o o o o o o o o o or r r r ra a a a a at t t t t t t t t to o o o o o o o o or r r r r r r r ry y y y y y y y y y y a a a a a a a a a a a a n n n n n n n n n n n n n n n n n n nd d d d d d d d d d d d d F F F F F F Fi i i i i i i ie e e e e e e e e e el l l l l ld d d d d d d d d d d d d T T T T T T T T T T T T T T T T T e e e e e e ec c c c c c c c c c c ch h h h h h h h h h h hn n n n n n n n n n ni i i i i i i iq q q q q q q q q q q q u u u u u u u u ue e e e e e e es s s s s s s N Ni N Ni Ni Ni N Ni N N Ni Ni N N N Nic ch c ch ch ch ch ch c ch ch ch chol ol ol ol ol ol ol o o o as as a as as as as as a as a as a E E E E E E E E E E E E E E E. . . . . . Jo Jo Jo Jo o Jo Jo Jo Jo J Jo o J Jone ne ne ne ne ne ne ne ne e ne es s s s s s s s s s 1 1 1 1 1 1 1 1 a a a a and nd nd nd d nd L L L L L L Lau au au u au u u u auri ri ri ri ri ri ri i i ri r e e e e e e e Al Al Al A Al A Al A A li li li li lin n n n 2 2 2 2 2 2

Upload: others

Post on 24-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

Ministry of Natural Resources

AAAAAAAAAqqqqquuuuuuaaaaatttttttttttiiiiiiiiicccccccccccc RRRRRRRRRRRRRRReeeeeeeeeeeeeeeeeeeeeesssssssssssssseeeeeeeeeeeeeeeaaaaaaaaaaarrrrrrrrrrrrrrrccccccccchhhhhhhhhhh aaaaaaaaaaaaaannnnnnnnnnnnnnddddddddddddddd DDDDDDDDeeeeeeeeeeevvvvvvvveeeeeeeeeeellllloooopppmmmmeeeennnnttt SSSSeeecccccttttiiiiioooooooooooonnnnnnnnnnn

AAAAAAAAAAqqqqqqqqqqquuuuuuuuuuaaaaaaaaatttttttttiiiiiiicccccccccccc RRRRRRRRRReeeeeeeeeeeeeeeeeeeeeeeessssssssseeeeeeaaaaaarrrrrrrrrrrrrccccccccccchhhhhhhhhhhh SSSSSSSSeeeeeeeeerrrrrriiiiiieeeess 2222000000011111111110000000--00033333 MMMMMMMMMMMMMeeeeeeeeeeaaaaaaaaaaaasssssssssssuuuuuuuuuuuurrrrrrrrrrriiiiiiiiiinnnnnnnnnngggggggggggggggggg SSSSStttttrreeeeaaaaaaammmmmmmmmm TTTTTTTTTTTeeeeeeeeeeemmmmmmmmmmmmppppppppppppppeeeeeeeeeeeerrrrrrrrrrrrraaaaaaaaaaattttttttttuuuuuuuuuurrrrrreeeeeeeeeee UUUUUUUUUUUUssssssssiiiiiiiiinnnnnnnnnnngggggggg DDDDDDDDDDDDaaaaaaaatttttttttttttttttaaaaaaaaaaaaaa LLLLLLLLLLLLLLooooooooooooooogggggggggggggggggggggeeeeeeeeeeeeeeeeeeerrrrrrrrrssssssssssssssss:::::::::::::: LLLLLLLLLLLLLLLLLLLLLLLLLLLLLaaaaaaaaaaaaaaaaabbbbbbbbbbbbbooooooooooooorrrrraaaaaattttttttttoooooooooorrrrrrrrryyyyyyyyyyyy aaaaaaaaaaaaaannnnnnnnnnnnnnnnnnnddddddddddddd FFFFFFFiiiiiiiieeeeeeeeeeelllllldddddddddddddd TTTTTTTTTTTTTTTTTeeeeeeecccccccccccchhhhhhhhhhhhnnnnnnnnnnniiiiiiiiqqqqqqqqqqqqquuuuuuuuueeeeeeeesssssss

NNiNNiNiNiNNiNNNiNiNNNNicchcchchchchchcchchchcholololololololooo asasaasasasasasaasaasa EE EEEEEEEEEEEEE..... . JoJoJoJooJoJoJoJoJJooJJoneneneneneneneneneeneesssssssssss11111111 a aa aandndndnddnd L LLL LL Lauauauuauuuuauriririririririiirir eeeee e e AlAlAlAAlAAlAA lililililinnnn222222

Page 2: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

Aquatic Research & Development Section Ontario.ca/aquaticresearch

Version 3.0 March 2010

1 Aquatic Research and Development Section, Ontario Ministry of Natural Resources, Trent University, DNA Building 2140 East Bank Drive, Peterborough, ON K9J 7B8

2 Aquatic Research and Development Section, Ontario Ministry of Natural Resources, RR4, 41 Hatchery Lane, Picton, ON K0K 2T0

© 2010, Queen’s Printer for OntarioPrinted in Ontario, Canada

MNR 52639ISBN 978-1-4435-2795-8 (PDF)

This publication was produced by:

Aquatic Research and Development SectionOntario Ministry of Natural Resources2140 East Bank DrivePeterborough, OntarioK9J 8M5

Online link to report can be found at: Ontario.ca/aquaticresearch

Citation: Jones, N.E. and L. Allin. 2010. Measuring Stream Temperature Using Data Loggers: Laboratory and Field Techniques. Ontario Ministry of Natural Resources, Aquatic Research and Development Section, OMNR-Trent University, Peterborough, Ontario. 28 pp.

Please send comments and suggestions on the manual to the River and Stream Ecology Lab, Aquatic Research and Development Section, [email protected]

Cette publication hautement spécialisée Measuring Stream Temperature Using Data Loggers: Laboratory and Field Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97, qui en exempte l’application de la

Loi sur les services en français. Pour obtenir de l’aide en français, veuillez communiqueravec le ministère des Richesses naturelles au [email protected].

Page 3: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

Ministry of Natural Resources

SUMMARY

Stream temperature is an aspect of water quality that affects every aquatic organism, and although not overly complex to measure, reliable measurements require careful planning. Stream temperatures vary considerably over both time and location. Although there has been some success relating single point-in-time temperature measurements to the thermal class of a stream we strongly advocate additional data gathered via data loggers to provide a time series that describes a stream’s thermal regime e.g., magnitude, duration and frequency, predictability, and fl ashiness. The methods described in this document were developed from considerable fi eld experience and are intended to assist others interested in measuring water temperature in fl owing waters. In this guide we provide advice in four areas including: (1) choosing a temperature data logger; (2) laboratory procedures; (3) fi eld procedures; and (4) retrieving and handling time-series temperature data. We also introduce ThermoStat, a tool for analyzing data in a consistent format for reporting purposes. This report is intended to help people conduct successful fi eld measurements to maximise the quality of their data and the information obtained.

RÉSUMÉ La température de la vapeur est un aspect de la qualité d’eau qui infl ue sur tous les organismes aquatiques, et même si sa mesure n’est pas excessivement complexe, elle demande quand même une préparation soigneuse. Les températures de vapeur varient de façon considérable dans l’espace et dans le temps. Même si nous avons pu relier une mesure de température à un moment donné à la classe thermique de la vapeur, nous encourageons fortement la collecte des données supplémentaires, à l’aide d’enregistreurs de données, pour obtenir une série chronologique décrivant le régime thermique d’une vapeur (c. à d. l’ampleur, la durée et la constance et le niveau de crue éclair). Les méthodes décrites dans le présent document ont été élaborées en se fondant sur les vastes expériences sur le terrain et visent à aider d’autres parties intéressées à mesurer la température de l’eau mouvante. Le présent guide contient des conseils dans quatre domaines, soit : (1) le choix de l’enregistreur de données de température; (2) les méthodes de laboratoire; (3) les marches à suivre sur le terrain; et (4) la récupération et la manutention d’une série chronologique de données de température. Nous présentons également l’outil ThermoStat utilisé pour analyser avec cohérence les données aux fi ns d’établissement de rapports. Ce rapport vise à aider les personnes à effectuer de bonnes mesures sur le terrain pour accroître autant que possible la qualité de leurs données et de l’information obtenue.

Page 4: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

3

Page 5: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

4

Table of Contents

Introduction ................................................................................................................... 5

Choosing a Temperature Data Logger ........................................................................ 7

Size of loggers .......................................................................................................................... 8

Accuracy and precision ........................................................................................................... 9

Type of data logger housing and durability .......................................................................... 9

Choosing a Sampling Interval .............................................................................................. 11

Laboratory Procedures............................................................................................... 12

Calibrating your data logger ................................................................................................. 12

Launching Procedures .......................................................................................................... 12

Field Procedures ......................................................................................................... 13

Placing the Logger in the Stream ........................................................................................ 14

Protecting your Data Logger in the Field............................................................................ 17

Documenting Logger Location and Site information ........................................................ 18

Safety ....................................................................................................................................... 19

Data Retrieval and Handling....................................................................................... 21

Exporting Data from Boxcar and Hoboware for ThermoStat .......................................... 22

Acknowledgments....................................................................................................... 23

Appendix...................................................................................................................... 25

Equipment List ........................................................................................................................ 25

Field Forms ............................................................................................................................. 26

Site Identification Summary .............................................................................................. 26 Stream Water Temperature: Data Logger...................................................................... 27

Page 6: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

5

Introduction

Thermal regime is of central importance in sustaining the ecological integrity of aquatic

ecosystems and limits the distribution and abundance of riverine species. Water

temperature can vary at small-scales (e.g., groundwater seeps) to large-scales (e.g.,

stream reaches). Similarly, water temperature can vary within hourly to annual time

scales. Temperature influences the overall water quality, rates of nutrient turnover,

metabolic activity, growth rates, timing of migration and spawning events and

distribution of stream organisms. Species-specific thermal preferences and tolerances

are the critical biological elements that define thermal habitat. Water temperature has

been described as the ‘abiotic master factor’ for fishes (Brett 1971; Poff et al.1997).

More recently, the “natural thermal regime” and its components: magnitude, frequency,

duration, timing and rate of change, have been acknowledged as fundamental variables

that must be incorporated in environmental flow standards (sensu Poff et al. 1997; Chu

et al. 2009; Olden and Naiman 2009).

Stream water temperatures are influenced by the source of stream water (e.g., ground

water, surface runoff, lake and wetland storage), solar radiation (including shading), air

temperature, land use practices, climate, precipitation and geologic setting (Stevens et

al. 1975). Temperature largely determines the formation, persistence, and break-up of

river ice which are important aspects of the physical character of streams and fish

habitat. Super-cooled water supports the formation of ice crystals in the water column

that accumulate as frazil ice; in turbulent water, this can be deposited on the riverbed to

form anchor ice. Anchor ice can grow to such an extent that it occludes the channel. It

can build up in shallow areas, forming ice dams that cause back-water effects. As

anchor ice thickens, it can become buoyant and float away, often taking with it parts of

the substratum. Frazil ice can have direct deleterious effects on fish by damaging the

delicate tissues of gills, even plugging the gills and suffocating the fish (Brown et al.

1994). Frazil can also accumulate beneath the ice sheet of slower reaches of the river,

forming hanging dams, which can fill most of the volume of pools and eliminate living

space for fish (Cunjak and Caissie 1994).

Page 7: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

6

Thermal alteration is the anthropogenic alteration of the natural thermal regime e.g.,

increase or decrease of water temperature. In general, at a local scale increases in

stream temperature arise from damming of water, loss of riparian vegetation, widening

of river channels, input of water from storm water ponds, and inputs of effluent water

used as a coolant by nuclear and coal-fired generating stations, and industrial

manufacturers. At the watershed scale water temperatures in river systems may be

altered by land-use within the watershed such as urban development, agriculture or

forest management. Stream temperature regimes are difficult to quantify, but available

evidence suggests that stream temperature regimes in many parts of North America are

now different from those that existed a century earlier. Alteration of these regimes in

turn may contribute to a decline of fishes e.g., salmonids. To best conserve and restore

river ecosystems, managers should restore the river's temperature regime, as closely as

possible, to its natural pattern of variability.

In 2004 the Ontario Ministry of Natural Resources, River and Stream Ecology Lab

embarked on a long-term study on the regional and temporal variation in the thermal

habitat of Great Lakes streams. During our six years of fieldwork we deployed over 400

temperature data loggers across the Great Lakes Basin. In addition, we received over

1000 files of temperature data from various agencies across Ontario. Many of the

agencies we contacted wanted to know more about assessing stream temperature and

thermal regime characteristics using data loggers, while others wanted some method to

store their temperature data for quick and orderly access. We learned a great deal

during our first year of sampling and data handling and thought this should be shared

amongst others looking to deploy temperature loggers to understand the thermal

characteristics of their streams. In addition to our on experiences we reviewed other

protocols and reports in the primary and gray literature e.g., Dunham et al. 2001, 2005;

Lewis et al. 2000; Zaroban 1999.

The purpose of this report is to provide guidance on the choice of logger, logger

deployment and retrieval, and data storage for people collecting stream temperature

data. This report is intended to help people reduce the observational variability, as

Page 8: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

7

opposed to natural variability of temperature data and to avoid differences in sampling

and analysis technique. While we do not specifically endorse the Onset Computer

Corporation series of temperature data loggers, most of our experience has been with

these loggers and most people collecting stream temperature data in Ontario use Onset

products.

Rationale for Measuring Stream Water Temperature Before heading out into the field or buying your loggers you should understand the

rationale for the proposed data collection. Ask yourself the following questions:

• what data are to be collected, time, places,

• duration of data collection, and

Examples of why we measure temperature include monitoring:

• pre- and post-treatment water temperature regimes.

• temperatures for fish related concerns (e.g., cold, cool, and warmwater guilds).

• temperatures in relation to point source influences (e.g., warm or cold water discharges).

• temperature patterns to validate or parameterize water temperature models (e.g.,

Bartholow 2000).

• temperatures to model responses of aquatic biota (e.g., Eaton et al. 1995).

Choosing a Temperature Data Logger This is the first important step in measuring stream water temperature. Similar to trends

in the personal computer industry, the sophistication of temperature data loggers has

increased during the past decade in mainly two directions, smaller and greater memory

capacity. There are many different types of data loggers on the market with a countless

array of options. Be sure your logger meets your needs. Think about the nature or type

of stream system you plan to monitor or study. Consider the following options and

features when purchasing a logger, longevity (memory capacity and battery life), size,

accuracy, precision, durability, waterproofness, battery type, and reliability. We strongly

advise that you discuss your needs with local distributors of stream data loggers and

with people who use loggers regularly.

Page 9: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

8

Longevity, memory capacity and battery life

Memory capacity is important if temperatures are to be recorded for long periods (e.g., >

1 year) or short sampling intervals (e.g., <15 min). Most data loggers today have a

minimum of 21k of memory that allows 21580 measurements. More measurements are

not necessarily better because data handling may become cumbersome. It may be

useful to create a table illustrating the number of observations generated given an

interval and recording length (Table 1) or how many days the logger can be used base

on various sampling intervals (Table 2). For example, 12 months recording with an

interval of 30 minutes will collect 17,280 measurements.

Table 1. The number of observations generated using varying time intervals (minutes). recording length (months).

Table 2. The number of days that can be recorded using varying time intervals (minutes) for a logger capable of 42,000 measurements. (

Size of loggers

Most temperature data loggers these days are small (e.g., 10 cm) although some may

require larger submersible cases. Generally the size of the logger is not an issue;

however, the smaller models may be more difficult to find in the field which might be

beneficial if vandalism or theft is a problem at the sampling locations.

Sampling interval (minutes) and number of observations Months 120 60 30 20 15 10

12 4320 8640 17280 25920 34560 43200

8 2880 5760 11520 17280 23040 28800

6 2160 4320 8640 12960 17280 21600

4 1440 2880 5760 8640 11520 14400

2 720 1440 2880 4320 5760 7200

Sampling interval (minutes) and number of observations

10 15 20 30 60 120

No. of Days 180 270 361 541 1084 2168

Page 10: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

9

Accuracy and precision

Most data loggers, when properly functioning, are very accurate and capable of

relatively precise ±1 to 0.2°C. However this accuracy may vary slightly with temperature

e.g., 0° to 50°C. Most manufacturers provide detailed information on the accuracy and

precision of their instruments. We found that loggers were accurate as described by

manufactures specifications e.g., accuracy: ± 0.2°C at 0° to 20°C. Bit resolution refers

to the smallest change that can be detected by the logger and is provided by most

manufactures. For example, some models with 8 bit resolution are sensitive to 0.16°C

whereas, higher bit models (12-bit) are capable of more precise measurements e.g.,

0.02°C.

Type of data logger housing and durability

Some data loggers are not submersible and must be deployed within sealed waterproof

housings. If you decide to use loggers that are made waterproof by using submersible

cases then you must consider two challenges. Data loggers within waterproof housings

are not in direct contact with the water, and are actually recording air temperatures

within the sealed housing. Heat transfer between the air within the housing and the

surrounding water is not immediate, but air temperatures within the housing should

track surrounding water temperatures (Figure 1). In laboratory tests where loggers were

subjected to extreme temperature differences, there is a short time lag (~30 mins)

required for the air within the housing to equilibrate with the surrounding water

temperature; whereas, for a waterproof logger (no housing) time lag is shorter (20 mins)

(Figure 2). The rate of change for the temperature is proportional to the temperature

difference. Thus, temperatures recorded from data loggers within housings may not

accurately track water temperatures on very short (e.g., 10 min) time scales.

Page 11: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

10

Figure 1. Comparison of two types of loggers, HoboTemp Pro and Hobo in submersible case in two different streams (a) a small

stream North Creek and (b) Shibagua River. North Creek is a small headwater steam on the southern border of the Shield and has

heavy riparian cover. Shibagua River is larger, off the Shield, and due to its size, the riparian vegetation has relatively little influence.

(a) North C reek

0

510

15

202530 N o case

C ased

(b) Shibagua R iver

0

5

10

15

20

25

30

Aug 3

Aug 10

Aug 17

Aug 24

Aug 31

Sept 7

D ate

Tem

pera

ture

(a ) North C reek

0

510

15

202530 N o case

C ased

(b) Shibagua R iver

0

5

10

15

20

25

30

Aug 3

Aug 10

Aug 17

Aug 24

Aug 31

Sept 7

D ate

Tem

pera

ture

Page 12: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

11

Hobo Temp Pro 1

Hobo Temp Pro 2

Cased 1

Cased 2

Hobo Temp Pro 1

Hobo Temp Pro 2

Cased 1

Cased 2

0

5

10

15

20

25

00 5 10 15 20 25 30 35 40 50

Minutes

Tem

pera

ture

0

5

10

15

20

25

0

5

10

15

20

25

30

5

10

15

20

25

30

0 5 10 15 20 25 30 35 40 50

(a)

(b)

Hobo Temp Pro 1

Hobo Temp Pro 2

Cased 1

Cased 2

Hobo Temp Pro 1

Hobo Temp Pro 2

Cased 1

Cased 2

0

5

10

15

20

25

00 5 10 15 20 25 30 35 40 50

Minutes

Tem

pera

ture

0

5

10

15

20

25

0

5

10

15

20

25

30

5

10

15

20

25

30

5

10

15

20

25

30

5

10

15

20

25

30

0 5 10 15 20 25 30 35 40 50

(a)

(b)

Figure 2. Comparison of two types of loggers, HoboTemp Pro and Hobo in submersible case, under two temperature change

scenarios (a) from room temperature down to zero oC by placing the loggers in ice water and (b) taking the loggers out of the ice

water to 30 oC tap water.

Loggers placed in clear or translucent cases may act as heat collectors and give

artificially high temperature values due to solar radiation warming inside the case (i.e.,

greenhouse effect. White, non-translucent cases are recommended to avoid solar

radiation warming. White cases, however, advertise their location and rarely remain

white for long due to algae growth.

Choosing a Sampling Interval

We suggest a sampling interval of 30 minutes although shorter intervals (e.g. 15 mins)

may be used in small, flashy streams or in relation to impact assessment (e.g.,

hydropower, urbanization). All this said, we strongly advice that a minimum of 30

Page 13: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

12

minutes be used. This time interval is also the preferred interval for analyses in

ThermoStat.

Laboratory Procedures

Pre-deployment is the second important step in measuring stream water temperature.

Too often we see loggers that were incorrectly programmed and launched resulting in

corrupted data and poor choice of sampling interval. In one case we obtained data

recorded every 0.5 seconds!

Calibrating your data logger

Regardless of the type of data logger used, it is good practice to make sure it is

functioning properly. Calibration is a relatively simple process and well worth the time,

given the consequences of inaccurate or no data. A procedure for calibrating data

loggers is the “ice bucket” method (see http://www.onsetcomp.com). The procedure

involves the following steps:

1. Deploy the data loggers at a short sampling interval (e.g., 1 minute).

2. Submerge data loggers in an insulated ice bath (e.g., a cooler with lots of ice and

water).

3. After at an hour, remove the data loggers and download the data. If the data

loggers are calibrated correctly the temperature readings should level-out at 0°C.

4. Check calibration both before and after data loggers are deployed and retrieved.

It is also advisable to use a NIST thermometer to test the accuracy of data

loggers at temperatures other than 0°C.

Launching Procedures

There are two ways of launching your data logger. Most popular is to program the

logger for a delayed start. A delayed start is recommended if the loggers will be

deployed at a later date or when you want your loggers synchronized so comparisons

among loggers (sites) can be made. Alternatively, you can set the logger to start

immediately. The latter method is rarely used today; however, older logger models

Page 14: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

13

typically do not have the delayed start option. We highly recommend synchronizing

loggers such that measurements are made at the same time e.g., 12:30, 13:00, 13:30

hrs. This synchronization makes statistical comparisons more valid. Regardless of the

method used, be sure to record the day and time the logger was deployed so you can

trim data at a later date. See Appendix I for suggested site identification and logger

field sheets. You might experience problems with your data if (i) the battery runs out, (ii)

the logger malfunctions, (iii) your loggers date and time was improperly set, (iv) you set

your logger to wrap around the current data, or (v) you did not physically place your

logger in a good location. Be aware of using daylight savings time (DST) or Greenwich

Mean Time (GMT).

Before the logger is deployed attach an identification tag (i.e. property of …, tidbit #,

please leave in water, contact number) to the logger with a cable tie. In the event that

the logger is found by a member of the public this tag may deter them from vandalism.

We have had people find our loggers and return them to us because of this tag.

The optic window on some loggers can become overgrown with algae. These algae can

be difficult to clean off in order to optically read the data. For some loggers a protective

boot can be purchased to protect the optical window. You should carry a tooth brush to

clean off the optic window. If the window on the tidbit V2 logger is dirty, the shuttle will

not be able to recognize the logger and will record a fail. Record on your field sheet the

type of logger, serial number and logger number. If needed replace faulty loggers with

fresh loggers. In the lab, try cleaning and downloading problem loggers again. If this

still fails to work, return the logger to seller where they should be able download via

other methods.

Field Procedures Field work is the third important step in measuring stream water temperature. Before

placing your logger in the stream you need to determine if the site will be frequented by

various users e.g. fishing, recreation etc. Ask yourself if the logger will be readily visible

to visitors? Are people going to tamper with it if they find it? Is this private or crown

Page 15: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

14

land? Is access going to be a problem in the future? Are beavers going to be a

problem? Will it be too dangerous or risky to access the stream (i.e., very steep, loose

rocks)? Look for fishing line and lures, beer cans, bottles, garbage and fire pits. In the

stream, look for any flow obstructions, try to avoid springs or seeps, make sure there is

mixing within the site and the water depth is sufficient even during low flow periods of

summer or winter. In Ontario, the best time to deploy and retrieve loggers is during the

low flow period of summer (July- September). You do not want to place your loggers too

deep that you cannot retrieve them the next year.

Placing the Logger in the Stream

It is well worth spending time on logger placement so that it is not lost. We have

successfully used three techniques for placing the logger in a stream or river. The

water depth and clarity will determine which technique to use (Table 3).

Table 3. Choosing an installation method depends on river or segment characteristics.

Type Turbid Bedrock dominated Dynamic alluvial Soft organic or silty

Staked Tethered Free-weight

Staked: Staking loggers involves using a 12-24” section of solid rebar 3/8-3/4” diameter

with a small hole 1/4” diameter at one end large enough to thread a small cable tie.

Make sure the hole in the rebar is sufficiently away from the end of the rebar to avoid

closure during hammering. This rebar is pounded into the substrate with a sledge

hammer or cupped pipe (mini post driver) (Figure 3). The cupped pipe is a solid bar of

metal 1” diameter with a short (3”) section of pipe welded onto the end. The rebar is

first hammered down to the water surface. Below the waterline we use the mini post

driver: hammering otherwise will lead to lots of splashing and misses. The cupped

portion of the driver leaves 2-4” of the rebar exposed. Attach the logger and tag via a

cable tie to the rebar. In many cases a flat rock can be placed on the exposed end of

the rebar thus concealing it from passer-by but do not impede water flow to the logger.

Page 16: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

15

Free-weight: If the water depth is suitable for wading/walking then take a long cable tie

(36-48 inches) or stainless-steel cable and attach the logger to a cinder block (Figure 4).

Carry the cinder block to your site location and physically place it securely in the stream.

Try to hide the cinder block by covering it with rocks but do not to impede water flow to

the logger.

Figure 3. A staked logger

(insert), mini post driver,

sledge, and stake.

Figure 4. Free-weight

e.g., cinder block.

Page 17: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

16

Tethered: If your water depth is greater than a metre or the stream is prone to moderate

turbidity then it is recommended that you use the tether technique (Figure 5). Other

notable factors are steep slopes, flashy streams, silt or clay substrates. This technique

will help you retrieve the logger upon return. To tether your logger:

1. Attach the logger and its information tag to a half cinder block with a large cable

tie. The logger should securely lie in the protective inner hole of the cider block.

This requires one small tie for the logger and one large tie for the block.

2. Cut a section of aircraft cable to an appropriate length needed to position the

logger.

3. Attach one end of the aircraft cable (1/8 -3/8” diameter) to a ½ cinder block with

an appropriately sized swage and use crimpers to clamp the swage onto the

cable.

4. At the other end of the cable attach a 12-24 inch section of solid rebar 3/8 to 3/4”

diameter with a small 1/4” diameter hole at one end large enough to thread the

cable. Make sure the hole in the rebar is sufficiently away from the end of the

rebar to avoid closure during hammering.

5. Throw the ½ cinder block into the river while holding on tight to the rebar.

6. Once the cinder block has settled to the bottom, hammer the rebar into the

substrate with a sledge hammer or cupped pipe (mini post driver) (Figure 3) so

the top is flush with the ground. Attach this end with a swage and use the

crimpers to clamp the swage onto the cable (Figure 5).

7. Make sure you place flagging tape in a tree close to the rebar and take a picture

so you can find it again.

8. Ensure the rebar and cable is flush to the bottom to avoid detection and

tampering. Placing a rock on top of the rebar helps keep it in place and hidden.

In shallow areas you might want to place rocks along the tether line to hide it

from view.

Make sure your tether line is long enough (double what you think is necessary). If you

are unsure of the water depth because of the turbidity use your pike pole to search for

Page 18: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

17

adequate water depth. We have had instances of tethered loggers drying up because

we did not use enough line to get out to deeper water.

Protecting your Data Logger in the Field

Try to protect your logger from human vandalism, flash flooding, eroding banks, ice

jams, drying out, freezing and animal disturbances. The best locations are on private

land. Private land and their owners deter access and help protect loggers from vandals.

Avoid high-use areas such as parks. If you must place a logger in a high use area,

camouflage your cinder block with rocks or paint. Aging cinder blocks take on the

colour of stream rocks over time. We have routinely used bridge crossings as stream

access points with few problems. Permanent structures such as bridge abutments and

large boulders offer a great deal of protection against high flow events, are

recognizable, and make good reference points. Try to use natural in stream rocks,

permanent log jams or boulders to secure your cinder block in the stream. The slower

Figure 5. Tethered half

cinder block.

Page 19: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

18

side of current breaks are also ideal locations for logger placement. We have had great

success with the free-weight and tethered methods. Try to avoid placing full cinder

blocks at the lip end of culverts, there are many beavers out there.

Ensure that water depth is sufficient so that the logger will not dry-out in summer or

freeze during the winter. If possible visually check loggers in the lowest flow periods in

the summer and winter. We check our loggers in the low flow period to ensure that

there is sufficient water i.e. no less than 0.3 m. Record the date, time and any

adjustments you made to the logger.

Documenting Logger Location and Site information

If your site will be hard for someone else to find, draw a map of its exact location and

attach it to your site identification form or field sheet. Remember you may not be the

person going back to the site to retrieve the loggers. In addition to a site sketch to help

locate the logger, we also strongly recommend recording the location of the logger in

the river with a GPS. Today’s GPS can even direct your travel route on roads to reach

your logger. A digital camera should be used to take a picture of the location of the

logger and surrounding reference structures e.g., large trees, bridges. Include the

person placing the logger in the picture at the exact location of the logger. The person

in the picture should point to the location of the submerged logger. Lastly, tie pieces of

flagging tape on tree branches directly perpendicular to the stream logger location.

These precautionary measures may seem cumbersome but it is much better than losing

a logger or spending an hour searching in the rain on a cold day in October. Finding

loggers in the field after one or two years can be challenging. Using the techniques

describe above will help you find the logger and retrieve your data.

On your data logger field sheet record the date (YYYY/MM/DD), the time (24 hour

clock), the deployment number, sampling interval of the logger, wetted stream width in

meters, depth of logger in meters, the degree of shading upstream based on riparian

vegetation height and stream width (high, medium or low), habitat type (pool or riffle),

Page 20: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

19

pre-calibration factor (if the logger was calibrated), location in stream, crew and any

other comments. An example field sheet is attached in the Appendix.

Although it is highly recommended that the site identification form be completely filled,

at a minimum, the stream name, UTM coordinates, and datum (e.g., NAD 83) should be

recorded. Site identification is crucial for ensuring that future users of the data know

where the data was collected. An example of our site identification field sheet is

attached in the Appendix. If you have loggers in the waterproof casings you should

lubricate the o-ring, and place a business card and desiccant pack inside.

Safety

It is highly recommended that you work in pairs, one person on shore and the other

person in the stream. If you are working on fast moving, large rivers or streams with

high algae/mosses which makes your footing very slippery you might want to wear a life

jacket (summer months) or a floater jacket (fall, winter and spring). It is also a good

idea to have a walking stick and polarized sunglasses to help see and feel the bottom

area of the stream. You should also carry a pair of gloves and wear them when

deploying and recovering loggers to avoid zebra mussel cuts, sharp rock cuts, cold

hands and other objects in the stream i.e. broken glass and wire fences. In some

situations, the person on shore should have a throw line handy. A hazard assessment,

safe operating procedures, and appropriate training should be conducted prior to

implementation of work.

Invasive Species Transfer

Note that invasive species transfer (e.g. Didymosphenia geminate) is a risk factor in this

work, particularly if you are visiting a number of streams over a large geographic area.

We encourage field staff to use waders that reduce transfer (no felt soles), wash their

waders between streams, and dry waders at the end of each day. Do not move used

cinder blocks among stream sites.

Spatial Thermal Variation and Sample Site Selection

Page 21: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

20

Typically resource staff want to collect temperature data representative of the stream.

This is easier said then done. Stream temperature will exhibit variation in time and

space (longitudinally, vertically, and laterally) the degree to which depends on a number

of factors. To obtain representative data consider how site and segment (1-103 m)

characteristics might influence your understanding of water temperature in a stream.

The following will strongly affect water temperature:

1) groundwater inflows, surface and subsurface;

2) side channels, confluence of tributaries;

3) landuse i.e. geology, forest cover/type, soils, riparian vegetation;

4) beaver ponds and other impoundments, natural and man-made;

5) wetlands, water withdrawals, effluent and sewage treatment plant discharge; and

6) channel morphology (particularly conditions that create isolated pools).

Abrupt changes in any of these factors may lead to sudden changes in water

temperature. Always place loggers in well mixed areas, but not in riffles prone to low

water flows, or in deep pools prone to hyporheic flows (transient groundwater). Deep

run and flat (glide) habitats are preferred locations. While the thalweg is certainly mixed

well and representative of a large volume of thermal habitat, sheer stresses are typically

highest there too.

Retrieving your Data Logger

Use the notes and pictures made during deployment to find the logger. Look for the

flagging tape that was placed perpendicular to the logger on the stream bank.

Depending on deployment technique, carry a pole with a hook on it so you can drag the

logger and cinder block up to shallower water. This pole will help you retrieve your

logger in turbid and/or deeply set loggers: it will also help you wade safely. If rebar was

used, look for the rock that was used to conceal the logger. A metal detector can be

used to find loggers (stake and tether) if other methods fail. If the logger is not found

then expand your search downstream of the most probable spot.

Page 22: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

21

After retrieving your data make sure you record the date (YYYY/MM/DD), time (24 hour

clock), post-calibration factor if desired, approximate wetted stream width in metres,

depth of logger in metres, signs of tampering, signs of logger drying out, crew and any

other comments. Follow the manufacturer’s directions for downloading data. Check the

battery level and replace dead or damaged loggers. See appendix II for the data logger

form.

Data Retrieval and Handling This is the fourth important step in measuring stream water temperature. We have seen

a high degree of variability in data formats and data corruption related to incorrectly

retrieving the data. We strongly recommend saving the raw data files for storage and

future access. Follow manufacturer’s instructions if you want to work with Microsoft

Excel. Note: we urge you to examine your date time data for errors in Excel.

We have created software for analyzing stream temperature data called ThermoStat.

This latest version of ThermoStat incorporates many of the great tools used in STATE

(Stream Temperature Analysis and Tool Exchange) and ThermoStat V1, and more, in a

desktop stand-alone platform. Go to http://people.trentu.ca/nicholasjones/tools.htm for

more information. Functionalities include:

• Automatically accept multiple data formats.

• Contain user defined settings for report output (e.g., Excel and Access friendly

files).

• Automatically analyze their data in a consistent format for reporting purposes.

• Error checking

• Thermographic explorer module

• Daily, monthly, seasonal and annual temperature statistics (mean, min, max,

range, SD).

• Days within optimal range and days above upper lethal for 40+ common species

in the Great Lakes.

Page 23: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

22

• User defined settings for unforeseen thermal criteria and species.

• Thermal guild statistics: warmwater, coolwater, and coldwater.

• Graphing temperature duration curves and area under the curve.

• Extremes: dates of thermal max and minimum temperature.

• Warming and cooling rates

The software is free. We ask that you send an email to nicholas.jones(AT)ontario.ca to

request the password. Your involvement will help guide decisions on further

development and investment. Your privacy will be respected and you will not be added

to someone else's mailing list. Check this website regularly for updates. Please do not

redistribute this software. If you know of someone else that may find this software useful

please direct them to this website to obtain their own copy directly.

We encourage you to review the ThermoStat Manual. Installation instructions are

provided in the manual. ThermoStat is programmed using Matlab and compiled as a

'standalone' package. However it is necessary to have the Matlab runtime environment

on your system which is bundled in the Zip file.

Exporting Data from Boxcar and Hoboware for ThermoStat

Export your data using the software supplied by your logger manufacturer (e.g.,

Hoboware), as a Text File. The data must be properly formatted for future use (e.g.,

ThermoStat see manual).

Storage and Archiving of Data: Field Sheets, Database, and Data

Once temperature and site identification data have been checked for errors, back-up all

data and digital photos. The raw field sheets and a copy of the data on disc should be

placed in an archive file box and stored in a heated location to avoid mildew and mould

problems. These are the originals and should never be handed-out.

Page 24: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

23

Hopefully you have a greater appreciation for obtaining quality time series data from

your temperature data loggers and will be better prepared for future temperature work.

Learn from our mistakes and the advice of others.

Acknowledgments We would like to thank all the people that have offered field advice and reviewed this

document.

Literature Cited

Bartholow, J.M. 2000. The Stream Segment and Stream Network Temperature Models: A Self-Study Course, Version 2.0 U.S. Geological Survey Open File Report 99-112. 276pp. (http://www.mesc.usgs.gov/training/if312.html)

Brett, J. R. 1971. Energetic responses of salmon to temperature. A study of some

thermal relations in the physiology and freshwater ecology of sockeye salmon (Oncorhynchus nerka). American Zoology 11: 99–113.

Brown, R. S., Stanislawski, S. S. and Mackay, W. C. 1994. Effects of frazil ice on fish. In

Prowse, T. D. (Ed.) Proceedings of the Workshop in Environmental Aspects of River Ice. pp. 261±278. NHRI Symposium Series No. 12, National Hydrology Research Institute, Saskatoon, Canada.

Chu, C., N.E., Jones, A.R. Piggott, J.M. Buttle. 2009. A simple method to classify the

thermal characteristics of streams from daily maximum air and water temperatures: revisited. North American Journal of Fisheries Management

Chu, C., N.E. Jones, and L. Allin. 2009. Linking thermal regime classification to climate

and landscape variables in Ontario. River Research and Applications. Cunjak, R. A. and Caissie, D. 1994. Frazil ice accumulation in a large salmon pool, in

the Mirimichi River, New Brunswick: ecological implications for overwintering fish. In Prowse, T. D. (Ed.) Proceedings of the Workshop in Environmental Aspects of River Ice. pp. 279±295. NHRI Symposium Series No. 12, National Hydrology Research Institute, Saskatoon, Canada.

Dunham, J., Rieman, B., Chandler, G. 2001. Development of field-based models of

suitable thermal regimes for interior Columbia basin salmonids. U.S.D.A. Forest Service Rocky Mountain Research Station Forestry Sciences Laboratory Boise, ID.

Dunham, J., G. Chandler, B. Rieman, D. Martin. 2005. Measuring stream temperature

with digital data loggers: a user's guide Gen. Tech. Rep. RMRS-GTR-150WWW. Fort Collins, CO: U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station. 15 p.

Page 25: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

24

Eaton, J. G., J. H. McCormick, B. E. Goodno, D. G. O'Brien, H. G. Stefany, M. Hondzo

and R. M. Scheller.1995. A field information-based system for estimating fish temperature tolerances. Fisheries 20(4):10-18.

Lewis, T.E., D.W. Lamphear, D.R. McCanne, A.S. Webb, J.P. Krieter, and W.D. Conroy.

2000. Regional Assessment of Stream Temperatures Across Northern California and Their Relationship to Various Landscape-Level and Site-Specific Attributes. Forest Science Project. Humbolt State University Foundation, Arcata, CA. 420pp.

Olden J.D., and R.J. Naiman. 2009 Incorporating thermal regimes into environmental

flows assessments: modifying dam operations to restore freshwater ecosystem integrity. Freshwater Biology doi:10.1111/j.1365-2427.2009.02179.x

Poff, N. L., J. D. Allan, M. B. Bain, J. R. Karr, K. L. Prestegaard, B. D. Richter, R. E.

Sparks and J. C. Stromberg. 1997. The Natural Flow Regime - A paradigm for river conservation and restoration. BioScience 47: 769-784.

Stevens, H.H., Jr. J. F. Ficke, and G.F. Smoot 1975. Water temperature – influential

factors, field measurement, and data presentation. Techniques of water-resources investigations of the United States Geological Survey, Book 1, Chapter D1. U. S. Department of the Interior. U. S. Government Printing Office, Washington, DC. 65p.

Zaroban, D.W. 1999. Protocol for placement and retrieval of temperature data loggers

in Idaho streams. Water quality monitoring protocols report #10. Idaho Department of Environmental Quality, Boise, ID.

Page 26: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

25

Appendix

Equipment List

life jackets polarized sunglasses first aid kit walking stick waders cell phone hook pole (pike) toolkit maps business cards gloves GPS unit and extra batteries Clipboard and field sheets, pencils calibrated loggers laptop computer inverter for lap top camera and batteries sledge hammer flagging tape cable cutters letters to landowners metal detector cinder blocks tags air craft cable 1/8 – 1/4 inch swages and crimper 1 or 2 foot length rebar 1/2 inch diameter cable ties (small, medium and large)

Page 27: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

26

Field Forms

Site Identification Summary

Stream Information Stream Name: Stream Code: Site Code:

Site Location UTM Coordinates: Grid: Easting: Northing:

Decimal degrees: Latitude Longitude

Geodetic Datum: (Check map legend or GPS set-up): NAD27 or NAD83

Site Description Township: Concession:

Lot: District:

Site Description: e.g., walk down path behind education centre. Walk to first bridge. Logger is beside

bridge under cedar tree.

Comments: Crew: Recorder:

Comments:

Page 28: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

27

Stream Water Temperature: Data Logger

Please provide a map if it would be difficult for another person to find the data logger. Picture? and #

Deployment of Logger Date (YYYY/MM/DD): ____________ Time: ____________ Deployment #: ____________

Sampling Interval: ____________ Lock #: ____________ Elevation(m): ____________

Wetted Width (m): ______________ Depth of Logger (m): ________________

Degree of shading upstream of site based on riparian vegetation height and stream width (circle): High Med Low Habitat Type (circle): Run Pool Riffle Pre-calibration Factor: _______

Deployment type: Staked Tethered Free-weight

Location in Stream:__________________________________________________________________________

__________________________________________________________________________________________

__________________________________________________________________________________________

Crew members and Comments_________________________________________________________________

Recovery of Logger Date (YYYY/MM/DD): ________________ Time: ____________ Post-calibration Factor: ________________

Approximate wetted Width (m): ___________________ Depth of Logger (m): ________________

Signs of Tampering: Yes No _______________________________________________________________

Signs of Logger Drying out: Yes No __________________________________________________

Crew: ____________________________________________________________________________________

Comments:_________________________________________________________________________________

File Information Owner of Data: ____________________________ Access Rights (circle): Yes No _________________

Filename: ________________________________ Quality Controlled (circle): Yes No ______________

Date of Data Download (YY/MM/DD): ________________ Time of Data Download: ________________

Page 29: Aquatic Research Series 2010-03 Measuring Stream ...nicholasjones/Measuring_Stream_Temperature.pdfField Techniques n’est disponible qu’en anglais en vertu du Règlement 411/97,

MNR 52639ISBN 978-1-4435-2795-8 (PDF)