System prior to dewatering worksite Baffle shifts to stabilize system Dewatered worksite; baffle has stabilized the system TM AQUA-BARRIER IS A WATER FILLED DAM THAT UTILIZES A PATENTED INTERNAL BAFFLE FOR STABILITY Available for Rent or Purchase Compact for Shipping & Storage Environmentally Friendly Available for Rent or Purchase Compact for Shipping & Storage Environmentally Friendly TM AQUA-BARRIER AN ESSENTIAL COMPONENT OF YOUR PIPELINE CONSTRUCTION PROJECT COMPACT IN SHIPPING & STORAGE TM AQUA-BARRIER OFFERS UNIQUE ACCESSORIES TO FACILITATE INFIELD USE DRAIN PORTS REPAIRABILITY END PIPELOOPS FILL PORTS 41232 Park 290 Drive, Bldg A • Waller, TX 77484 Schedule # GS-07F-0543N

Upload: darren-miller

Post on 14-Aug-2015

55 views

Category:

Documents


0 download

TRANSCRIPT

System prior to dewatering worksite Baffle shifts to stabilize system Dewatered worksite;baffle has stabilized the system

TM

AQUA-BARRIER IS A WATER FILLED DAM THAT UTILIZES A PATENTED

INTERNAL BAFFLE FOR STABILITY

Available for Rent or Purchase Compact for Shipping & Storage

Environmentally Friendly

Available for Rent or Purchase Compact for Shipping & Storage

Environmentally Friendly

TM

AQUA-BARRIER

AN ESSENTIAL COMPONENT

OF YOUR

PIPELINE CONSTRUCTION PROJECT

COMPACT IN

SHIPPING & STORAGE

TMAQUA-BARRIER OFFERS UNIQUEACCESSORIES TO FACILITATE INFIELD USE

DRAIN PORTS

REPAIRABILITY

END PIPELOOPS

FILL PORTS

41232 Park 290 Drive, Bldg A • Waller, TX 77484

Schedule

# GS-07F-0543N

PIPELINE INSTALLATION & REPAIRPipeline repair or replacement projects can be complex, particularly when water is present. We understand that pipeline repairs often require completion in a short time frame. Aqua-Barriers™ provide the fastest cofferdam method available. The next time that you are confronted with a temporary cofferdam need, let us save you time and money.

The Canal Block Formation is

beneficial when working in narrow

channels. Water pumps or

diversion pipes can be utilized to

maintain appropriate upstream

water levels.

PIPELINE INSTALLATION & REPAIR

PARTIAL BLOCK FORMATION

COMPLETE ENCLOSURE FORMATION

CANAL BLOCK FORMATION

T h e C o m p l e t e

Enclosure Formation

is beneficial when

access to the shoreline

is difficult.

The Partial Block Formation is

beneficial when creating a work area

on a shoreline.

Aqua-Barrier™ Water Inflated Dam Product Specification

1.1 Specification A water-inflated temporary dam shall consist of the following: 1) The water inflated dam will consist of a self contained, single tube with an

inner restraint baffle(s)/diaphragm(s) stabilization system. The water-inflated dam must have the ability to stand alone, without any additional external mechanical or gravitational stabilization devices, as a positive water barrier and water management system.

2) The water-inflated dam shall be produced from heavy gauge polyvinyl chloride (PVC) reinforced

with polyester. The PVC fabric used to create the inflatable dam will be infield repairable utilizing a vinyl adhesive and patch material.

3) The water-inflated dam must maintain mechanical stability in addition to providing anti rolling when exposed to uneven hydrostatic pressure from either side

4) The self-contained water inflated dam shall have threaded fill ports and drain ports for rapid inflation and draining. The dam will be equipped with end lifting loops used to control the dam with equipment during the installation and removal process.

5) Method for connecting the individual units together will consist of overlapping the end of the units a specific length which will create a watertight connection. No other devices or methods for connecting the barriers are required.

1.2 Aqua-Barrier™ Product Description Aqua-Barriers™ are water-inflated dams used to control invasive water in floodwater situations, a means of water management to provide access to underwater areas for construction and maintenance operations, hazardous liquid containment, sediment retention in environmentally sensitive areas in addition to a continually expanding list of water control related applications. Aqua-Barriers™ are a single tube devise with a patented inner restraint baffle(s)/diaphragm(s) stabilizing system required for stability. 1.3 Dam size requirements The water-inflated temporary dam height shall be determined as follows: 1) Static water height conditions shall not exceed 75% of the properly filled height of the barrier. 2) Dynamic water height conditions shall not exceed stated value during hydrodynamic installation

procedures (See dynamic installation instructions for complete list of requirements). 3) Installation site criteria are required for assessment of all relevant factors. Excess slope, high water velocities, dynamic loads resulting from wave actions, mounting surface irregularities, and changes in interrelated hydrological conditions can increase the required water inflated dam height verses retention height requirements.

Hydro-Solutions, Inc. 5119 Ashley Court Houston, TX 77041 Ph 800-245-0199 Fax 832/243-9109

Aqua-Barrier™ Water Inflated Dam Product Specification

1.1 Specification A water-inflated temporary dam shall consist of the following: 1) The water inflated dam will consist of a self contained, single tube with an

inner restraint baffle(s)/diaphragm(s) stabilization system. The water-inflated dam must have the ability to stand alone, without any additional external mechanical or gravitational stabilization devices, as a positive water barrier and water management system.

2) The water-inflated dam shall be produced from heavy gauge polyvinyl chloride (PVC) reinforced

with polyester. The PVC fabric used to create the inflatable dam will be infield repairable utilizing a vinyl adhesive and patch material.

3) The water-inflated dam must maintain mechanical stability in addition to providing anti rolling when exposed to uneven hydrostatic pressure from either side

4) The self-contained water inflated dam shall have threaded fill ports and drain ports for rapid inflation and draining. The dam will be equipped with end lifting loops used to control the dam with equipment during the installation and removal process.

5) Method for connecting the individual units together will consist of overlapping the end of the units a specific length which will create a watertight connection. No other devices or methods for connecting the barriers are required.

1.2 Aqua-Barrier™ Product Description Aqua-Barriers™ are water-inflated dams used to control invasive water in floodwater situations, a means of water management to provide access to underwater areas for construction and maintenance operations, hazardous liquid containment, sediment retention in environmentally sensitive areas in addition to a continually expanding list of water control related applications. Aqua-Barriers™ are a single tube devise with a patented inner restraint baffle(s)/diaphragm(s) stabilizing system required for stability. 1.3 Dam size requirements The water-inflated temporary dam height shall be determined as follows: 1) Static water height conditions shall not exceed 75% of the properly filled height of the barrier. 2) Dynamic water height conditions shall not exceed stated value during hydrodynamic installation

procedures (See dynamic installation instructions for complete list of requirements). 3) Installation site criteria are required for assessment of all relevant factors. Excess slope, high water velocities, dynamic loads resulting from wave actions, mounting surface irregularities, and changes in interrelated hydrological conditions can increase the required water inflated dam height verses retention height requirements.

Hydro-Solutions, Inc. 41232 Park 290 Road Bldg A Waller, TX 77484 800/245-0199

AQUA-BARRIER FEATURES AND BENEFITS

PATENTED BAFFLE SYSTEM:

The Aqua-Barrier utilizes a patented fixed internal baffle system which insures a

safe and stable system. When the Aqua-Barrier is exposed to uneven hydrostatic

pressure, the internal baffle system locks into place. The Aqua-Barriers’ system

provides stability & safety.

USER FRIENDLY:

Aqua-Barriers have a unique lifting loop on each end which enables a track hoe

arm to control the barrier while installing and removing. This allows for

minimal manual labor during the installation & removal process.

ENVIRONMENTALLY FRIENDLY:

Aqua-Barriers are installed using the available water source at the jobsite with

minimal adverse impact to the environment. Post job restoration is not needed

using Aqua-Barriers. Simple drain and remove the barriers from the water with

little or no turbidity.

LARGE SCALE JOBS:

Multiple Aqua-Barriers can be connected together to cover large areas. The

Aqua-Barriers are connected to one another by utilizing a simple overlapping

procedure that requires no additional time during the installation and no

potentially hazardous underwater work

SAVE TIME AND MONEY:

Aqua-Barriers install in less time than most conventional cofferdam methods.

Approximately 500 linear feet of Aqua-Barriers can be installed in 1 day using 6

men, 2 track hoes and 2 water pumps

DURABILITY:

Aqua-Barriers are made with a scrim reinforced PVC material and industrial

grade fittings and intended to be reused numerous times. The Aqua-Barrier

system is infield repairable in wet or dry conditions utilizing a repair kit which

is provided with each order.

AQUA-BARRIER REFERRALS - PIPELINE & UTILITY LINE PROJECTS

Submar Michael Gallup 805 Dunn St. Houma, LA 70360 985/ 868-0001 325 linear feet of the 6-ft high Aqua Barriers were used for pipeline repair outside of Riverside Arkansas. This was the company's first use of the Aqua Barriers. Customer said "the product worked well and we are very pleased." Marathon Petroleum Company Alan Schulze 539 South Main Street Findlay, OH 45840 419/957-5235 140 linear feet of 8-ft high Aqua-Barriers were used for pipeline inspection; used instead of sandbags. B and G Pipeline Company Monte Himshoot PO Box 1285 Searcy, AR 72145 501/305-3677 200 linear feet of 8-ft high Aqua-Barriers were used for a pipeline project in Central, AR. Geeding Construction Greg Geeding 600 Hwy H Troy, MO 63379 314/486-5361 400 linear feet of 8-ft high Aqua-Barriers were used for a pipeline repair in the middle of a lake. Customer said “the product exceeded my expectations.” McCizer Pipeline Inc Larry McCabe 1416 S Evening St Judsonia, AR 72081 501/729-1147 100 linear feet of 4-ft high Aqua-Barriers were used for a pipeline dig project in Russellville, AR.

Latex Construction Matt Sullivan PO Box 43406 Atlanta, GA 30336 404/691-0349 75 linear feet of 6ft. high Aqua- Barriers were used on the Atlanta Gas Light pipeline project. Sunland Construction Co. Shannon Jet 5401 Kauloosa Tuscaloosa, AL 35405 205/750-2004 150 linear feet of 8ft high Aqua-Barriers were used to do an installation on Mill Creek. Cravens Partners, LTD Travis Schulze 7700 San Felipe, Suite 485 Houston, TX 77251-1660 713/300-1526 50 linear feet of 4ft high Aqua-Barriers were used to replace water line under bayou. Juniper Hill Golf Course Dudley Darling 202 Brigham Street Northboro, MA 01532 508/393-2444 (2) 8ft x 30ft Aqua-Barriers were used for a pump station intake repair project. Unity Construction Co., Inc. Alan Hamby 3941 Flint Hill Road Powder Springs, GA 30127 770/943-9886 225 linear feet of 6ft high Aqua-Barriers were used for installation of raw water intake for Newnan Utilities in Newnan, GA Florida Gas Transmission Co. Gary Corless 601 S. Lake Destiny, Suite 450 Maitland, FL 32751 407/838-7109 200 linear feet of 8ft high Aqua-Barriers were used for pipeline repair in Orlando, FL.

Mears Group, Inc. Jay Fluharty 4500 N. Mission Rosebush, MI 48878 989/433-2929 (1) 8ft x 55ft Aqua-Barrier was used for a waterline installation project in Knoxville, TN. Foutz & Bursum Gill Millstine PO Box 187 Bloomfield, NM 878413 505/634-4000 (2) 4ft x 50ft Aqua-Barriers were used for gas pipeline repair in San Carlos, AZ. Tanner Pipeline Poke Naquin 68022 I 10 East Baytown, TX 77521 281/839-3905 200 linear feet of 4ft high Aqua-Barriers were used for pipeline installation projects crossing several streams in Nashville, TN Koch Pipeline Will Swisher 8606 IH 37 Corpus Christi, TX 78409 361/242-5536 275 linear feet of 7ft high Aqua-Barriers were used for pipeline repair projects in sensitive wetland areas in and around Corpus Christi. Latex Construction Tom Cochran 51455 St. Hwy 255 Bay Minette, AL 36507 251/580-3317 200 linear feet of 7ft high Aqua-Barriers were used to install pipeline across several environmentally sensitive streams in the Mobile, AL area.

Progressive Pipeline Company Mike Castle, Jr. PO Drawer 100 Livingston, AL 35470 205/652-6512 (2) 7ft x 75ft Aqua-Barriers were used in a pipeline installation project for Florida Gas project located in an environmentally sensitive wetlands area with access restrictions Wanasek Corporation Jim Wanasek 29606 Durand Avenue Burlington, WI 53105 262/763-3561 400 linear feet of 6ft high Aqua-Barriers were used for a sewer line installation in Burlington, WI across the Fox River. Worked 24hrs/day and was able to complete the project in 5 days – (two days ahead of schedule) ET Mackenzie Bob Farrier 4248 West Saginaw Grand Ledge, MI 48837 517/627-8408 325 linear feet of 7ft high Aqua-Barriers were used for sewer line crossing in Lansing, MI. Work completed in just 1 week. Anderson Underground Dave Anderson 1202 Ipsen Road Belvidere, IL 61008 815/332-5700 525 linear feet of 6ft high Aqua-Barriers were used to install utility line across 300ft wide Fox River in Oswego, IL. Work completed in 5 days Brown Builders James Brown 2807 Clinard Drive Springfield, TN 37172 615/384-5654 (1) 8ft x 50ft and (3) 6ft x 75ft Aqua-Barriers were purchased for utility line installation that crossed several streams in Springfield, TN

US Pipeline, Inc. Johnny Pee 11767 Katy Fwy, Suite 100 Houston, TX 77079 281/531-6100 600 linear feet of 6ft high and 300 linear feet of 4ft high Aqua-Barriers were used to cross a stream in Towner, ND for the Alliance Pipeline project. The barriers were successfully deployed and removed in just 7 days. Dominion Transmission Tom Verden PO Box 2450 Clarksburg, WV 26302 304/623-8000 Aqua-Barriers were used in Tompkins, County, NY to install gas pipeline across a stream. Bryant Electric Co., Inc. Richard Money PO Box 4819 Archdale, NC 27263-1811 910/434-9232 6ft high Aqua-Barriers were used to dewater a portion of the Roanoke River to allow for the installation of a pipeline.