appropriate law cost techniques in rural water supply schemes
DESCRIPTION
APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES. H,M.GUNAPALA(E/A) RWS-Unit Monaragala MAHINDA DISSANAYAKE RWS-Unit Badulla. Why we need Law cost techniques ?. To minimized the overall cost in rural water supply scheme’s. What are the law cost techniques. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/1.jpg)
APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES
H,M.GUNAPALA(E/A)RWS-Unit MonaragalaMAHINDA DISSANAYAKERWS-Unit Badulla
![Page 2: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/2.jpg)
WHY WE NEED LAW COST TECHNIQUES ?
To minimized the overall cost in rural water supply scheme’s
![Page 3: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/3.jpg)
WHAT ARE THE LAW COST TECHNIQUES
Ferrocement Ground reservoir's Ferrocement elevated Tanks Ferrocement roughing filter’s Ferrocement Slow sand filter’s
FERROCEMENT TECHNIQUES COULD BE BEST OPTION
![Page 4: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/4.jpg)
Plastic shell roughing filter’sPlastic shell rainwater harvesting tank
Other techniques
NEXT
![Page 5: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/5.jpg)
Ferrocement Ground reservoir's
Back
![Page 6: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/6.jpg)
FERROCEMENT ELEVATED TANKS
Back
![Page 7: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/7.jpg)
FERROCEMENT ROUGHING FILTER’S
Back
![Page 8: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/8.jpg)
FERROCEMENT SLOW SAND FILTER’S
Back
![Page 9: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/9.jpg)
PLASTIC SHELL ROUGHING FILTER’S
Back
![Page 10: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/10.jpg)
PLASTIC SHELL RAINWATER HARVESTING TANK
Back
![Page 11: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/11.jpg)
SRI LANKA CHRONOLOGICAL ORDER 1980 –Sarvodaya/Danida Project(capacity up
to 10 - 15 Cm) 1990 – CWSSP Project (capacity up to 40
Cm) 1995-NWS&DB – Small town water supply
and sanitation project (capacity up to 40 Cm)
2000-NWS&DB – ADM 3rd project (capacity up to 100
Cm)
![Page 12: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/12.jpg)
HOW TO CONSTRUCT FERROCEMENT TANK ?
Tank Base Tank wall Tank Dome
PARTS OF FEROCEMENT TANK
NEXT
![Page 13: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/13.jpg)
TANK BASE
Back
![Page 14: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/14.jpg)
TANK WALL
Back
![Page 15: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/15.jpg)
TANK DOME
Back
![Page 16: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/16.jpg)
CONSTRUCTION MISTAKES OCCURRED DURING CONSTRUCTION PERIOD Pipes arrangement (inlet,outlet &wash out pipe) not
placing correct place Tank wall not align correctly Dome is not construct ' correct shape Wall thickness is increased than recommended thickness 4.5 mm dia GI wire not connected to base properly 4.5 mm dia
GI wire is not fixed to the wall in correct distance Neglect water cement ratio Neglect quality of materials Curing is not done properly
NEXT
![Page 17: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/17.jpg)
PIPES ARRANGEMENT (INLET,OUTLET &WASH OUT PIPE) NOT PLACING CORRECT PLACE
Back
![Page 18: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/18.jpg)
TANK WALL NOT ALIGN CORRECTLY
Back
![Page 19: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/19.jpg)
DOME IS NOT CONSTRUCT ' CORRECT SHAPE
Back
![Page 20: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/20.jpg)
4.5 MM DIA GI WIRE NOT CONNECTED TO BASE PROPERLY
Back
![Page 21: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/21.jpg)
4.5 MM DIA GI WIRE IS NOT FIXED TO THE WALL IN CORRECT DISTANCE
Back
![Page 22: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/22.jpg)
OUT COMES OF CONSTRUCTION MISTAKES Tank will be out of shape Water leak can be occurred Construction cost would be increased Durability of the tank would be decreased
NEXT
![Page 23: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/23.jpg)
TANK WILL BE OUT OF SHAPE
BACK
![Page 24: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/24.jpg)
WATER LEAK CAN BE OCCURRED
BACK
![Page 25: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/25.jpg)
COMPARISON OF FEROCEMENT TANK &CONCRETE TANK(ADB 3RD PROJECT-MONARAGALA)
Table -01
Table -02
NEXT
![Page 26: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/26.jpg)
Tank option
Cost in SLR
Tank Base concrete
Wall concrete
Concrete cover slab
Ferro cement wall & dome
Structural frame work
R/F & mesh
shuttering Pipes, specials etc
Total
50 cum Ferro cement tank
20020
---
---
37240
---- 50820
---- 46480 154560
50cum concrete tank
58870
79520
23450
----
---- 134890 66640 49630 413000
60 cum Ferro cement Tower
66500
----
----
47250
91630 208460 107660 144130 585900
60 cum concrete Tower
84770
134400
32200
----
161700 30930 195300 161000 1078700
Table 1
BACK
![Page 27: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/27.jpg)
Description
Cost for Ferro cement tank SLR
Cost for concrete tank SLR
Percentage reduction compared to concrete tank
30 cum ground tank110740 280000 60 %
50 cum ground tank154560 413000 67 %
30 cum elevated tank 6.8m (height)341180 585900 42 %
60 cum elevated tank 9 m (height) 665630 1078700 38 %
BACK
![Page 28: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/28.jpg)
HOW TO REPAIR FERROCEMENT TANKS
![Page 29: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/29.jpg)
![Page 30: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/30.jpg)
![Page 31: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/31.jpg)
VIDEO – 01VIDEO – 02VIDEO – 03
How to repair ferrocement tanks
![Page 32: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/32.jpg)
ADVANTAGES OF FERROCEMENT TECHNOLLOOGY Law cost for general types of constructions Simplicity in technology Not much skill labour required Required tools and equipment can be found
easily Light weight and therefore easy handling Easy repairs and maintenance Adequate strength for rural development Adequate durability Protection against sunshine and flooding Easy removal
![Page 33: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/33.jpg)
OTHER APPLICATION OF FERROCEMENT TECHNIQUES Intake well dome Water pond Patrician wall Domestic water storage tank Rainwater harvesting tanks toilets Chlorine house
NEXT
![Page 34: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/34.jpg)
INTAKE WELL DOME
BACK
![Page 35: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/35.jpg)
INTAKE WELL DOME
VIDEO
BACK
![Page 36: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/36.jpg)
WATER POND
BACK
![Page 37: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/37.jpg)
PATRICIANS WALL
BACK
![Page 38: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/38.jpg)
DOMESTIC WATER STORAGE TANK
BACK
![Page 39: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/39.jpg)
RAINWATER HARVESTING TANKS
BACK
![Page 40: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/40.jpg)
TOILETS
BACK
![Page 41: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/41.jpg)
BACK
![Page 42: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/42.jpg)
OTHER APPLICATION-FOREIGN COUNTRIES
![Page 43: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/43.jpg)
OTHER APPLICATION-FOREIGN COUNTRIES
![Page 44: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/44.jpg)
Other application-foreign countries
![Page 45: APPROPRIATE LAW COST TECHNIQUES IN RURAL WATER SUPPLY SCHEMES](https://reader035.vdocuments.us/reader035/viewer/2022062410/5681638a550346895dd47a2d/html5/thumbnails/45.jpg)
THANK YOU