applied controls analytical system integration 2014 national sales meeting cga: continuous gas...
TRANSCRIPT
![Page 1: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/1.jpg)
Applied Controls Analytical System Integration
2014 National Sales Meeting
CGA: Continuous Gas Analyzers Analyzer or Application – The Question
Bruce Herman - ABB Process Analytics
![Page 2: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/2.jpg)
© Copyright 2014 ABB
All rights reserved
“The information contained in this document is to be used only for the purpose intended. Any unauthorized use, reproduction, distribution or disclosure to third parties without
permission is strictly forbidden. ABB reserves all of its intellectual property rights in and to the information and the document.”
![Page 3: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/3.jpg)
ANALYZERS and APPLICATIONS
• name where ABB sells CGA analyzers
• identify measuring points in the major applications
• select the right analyzer modules for applications
![Page 4: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/4.jpg)
Agenda - Focus Points • CGA• The Frankfurt Connection
PRESENTATION FOCUS
• Product overview• CGA: AO2000
CGA –the product
• Where do you find CGA • Emissions • Process
APPLICATIONS
• POI• (Points of Interest) DIALOG
![Page 5: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/5.jpg)
Advance Optima –• Available for >15 years• Powerful controller logic • Class 1, Groups A,B,C,D,
Div 2 • Engineered
ADVANCE OPTIMA 2000
Reliable – Economic – Powerful
![Page 6: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/6.jpg)
Continuous Gas Analyzers
COCO2
NOxO2
Sample Handling
The Benefits of an Integrated Analyzer Concept
![Page 7: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/7.jpg)
The most important area of applications for continuous gas analysis. Combustion processes can be found in many different industrial areas,
![Page 8: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/8.jpg)
COMBUSTION PROCESSES • the generation of heat
• and electricity,
• Process steam production,
• Municipal and hazardous waste incineration,
• Surface treatment for example in annealing processes,
• Melting processes as used in metal or glass production,
• Roasting process for example iron ore roasting, sintering,
• Steel production and
• Cement production, … to name only the most important.
![Page 9: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/9.jpg)
• CO2, H2O, N2 expected
• CO, HC, excess O2 incomplete combusion
• SO2, NOx Sulfur in fuel, N2
• HCl, HF (Waste Incin)
• Hg, Particulates
![Page 10: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/10.jpg)
![Page 11: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/11.jpg)
Combustion efficiency Ideal combustion needs the right amount of oxygen.
The oxygen value can be measured with a paramagnetic oxygen analyzer
![Page 12: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/12.jpg)
Efficiency of DeNOx process Nitrogen oxide and nitrogen dioxide are a major cause for environmental damage.
These components are removed by injection of ammonia.
The injection of ammonia is regulated via the NO/NO2 concentration in the exhaust gas. The efficiency of this process is controlled by monitoring the outlet for excess ammonia. Analyzers used are infrared photometer
Infrared for NO or alternatively ultra-violet photomete for NO and NO2, and laser
analyzer for NH3 measurement.
![Page 13: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/13.jpg)
Electrostatic precipitator The typical measuring component is carbon monoxide.
Since CO is a flammable gas this measurement represents a safety measurement to avoid explosions.
Infrared photometer.
![Page 14: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/14.jpg)
Efficiency of the DeSOx process (desulfurization) The efficiency of the flue gas desulfurization is monitored
by measurement of SO2 with Infrared.
Alternately UV
![Page 15: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/15.jpg)
![Page 16: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/16.jpg)
The analyzer modulesmodule name type typical
Uras 26 NDIR photometer CO, CO2
Limas11 IR IR photometer CO,CO2,
HCl
Limas11 UVLimas 23 UV
UV photometer NO, NOx
Magnos 206 Paramagnetic, dumbbell
O2
Magnos27 Heavy duty O2
Caldos 27 Fast silicon sensor, TC
H2
Caldos 25 Glass coated TC ChlorineNH3, SO2
FIDAS24 Flame ionization
Fidas24NMHC
Flame ionization Non-meth HC, VOC
ZO23 Zirconium dioxide O2 traces
LS4000 Laser in-situ O2, CO, NH3
Oxygen cell chemical O2
![Page 17: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/17.jpg)
ADVANCE OPTIMA 2000
ABB
![Page 18: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/18.jpg)
Analyzer Modules
Infrared Analyzer Module ABB Uras 26 CO
CO2SO2NOCH4….
![Page 19: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/19.jpg)
Uras26Fulfils all the requirements for a lot of applications
High Stability of zero and span point<1% drift per week
High Sensitivityand smallest measuring ranges 0... 5 ppm CO2
High Selectivitysmallest cross sensitivities optimized for the main applications
Smallest detection limits< 20 ppb in a range of 0…5 ppm CO2
Suppressed range like 98…100 Vol% N2O
High repeatability< 0,5% of the range
Gas filled detector
Membrane condensator
Sample cell
![Page 20: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/20.jpg)
N2
CO SO2
NO CH4
N2
N2
N2
N2
NO
CH4
N2
N2
N2
CO
SO2
p
Infrared, Principle
ABB Uras 14with 4 measured componentsand calibration cells
![Page 21: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/21.jpg)
Analyzer Modules
Photometer Analyzer Modules ABB Limas 11-UV/IRABB Limas 23 UV NO
SO2NO2
NOx = NO + NO2
![Page 22: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/22.jpg)
Limas 11-UV Various Measuring components: NO, NO2, SO2, H2S, CS2, COS, Cl2 and NH3
Low measuring ranges: 10 ppm NO,
High Selectivity by best choice of- Interference and Gas Filter- Internal cross-sensitivity correction
High Stability due to electrodeless source & unique 4-Beam Method
Compact & economical solution for flammable, corrosive & toxic process gases
Calibration without test gas bottles
Simple adaption to the measuring task
![Page 23: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/23.jpg)
Limas 11 - Schematic DrawingM
M M
Source FW1
FW2
CU
D2
D1
MC
CL1CL2
CL3
BS
IR - Source M MotorFW1 Filter wheel 1FW2 Filter wheel 2
BS Beam splitterMC Measuring cuvetteCL1,2,3 Collimator lensesD1,2 Detectors
CU Calibration unitIF Interference filtersGF Gas filters
IF
GF
GF
IM1
IR1
IM2
t
IR2
t
![Page 24: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/24.jpg)
Analyzer Modules
Oxygen Analyzer ModulesMagnos 206/27
![Page 25: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/25.jpg)
Magnos – and Oxygen Technology
•Magnos206•Measurement in many applications•Very few interferences •Paramagnetic analyzer•Measuring with a dumbbell
•Magnos27• Preferred for rugged
applications• No moving parts • Paramagnetic analyzer • Measuring using thermal
character
•Electrochemical • Simple and economical
•Laser Diode • In Situ • NOT Paramagnetic
![Page 26: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/26.jpg)
Magnos 206Fast, Reliable MeasurementMagneto-Mechanical Principle
![Page 27: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/27.jpg)
Magnos27 Technology
N
S
N
S
Paramagnetism of oxygen
Two chamber system (measurement and reference)
Measurement chamber is located in a magnetic field
Temperature dependent resistors
Measurement effect: Increased circulatory flow proportional to oxygen concentration measured through thermal conductivity.
![Page 28: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/28.jpg)
N
S
Temperature dependentresistors
( Pt/Glass ... ca. 180 °C )
Bypass
60 °C
Magnos 27Robust Measuring Cell Thermomagnetic Principle
![Page 29: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/29.jpg)
Oxygen SensorExtended Range of Application,Suited for Stack Gas Monitoring
PTFE Membrane
Cathode ( Au )
Anode ( Pb )
-
+
Sample gas
Electrolyte ( acidic )
![Page 30: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/30.jpg)
LS4000 (TDL) Overview
In situ tunable diode laser analyzer
Measurement of oxygen (from 0-1 to 0-100Vol%)
Stand-alone operation
Compact & flameproof housing approved for use in hazardous areas (ATEX/IECEx/FM/CSA) (Class I, Div 1)
Dynamic correction of changing process conditions
![Page 31: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/31.jpg)
LS4000Product overview
![Page 32: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/32.jpg)
Caldos 25Highly corrosion resistantglass coated resistors
![Page 33: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/33.jpg)
Caldos 25Independent of Ambient PressureSophisticated Measuring Cell
Reference side Measuring side
Bypass
Glass-coated
Glass
60 °C
![Page 34: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/34.jpg)
Caldos 17Fast Measurement
![Page 35: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/35.jpg)
Analyzer Modules
FID Analyzer ModuleFIDAS24
![Page 36: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/36.jpg)
Fidas24Key Features at a Glance
New FID analyzer for Advance Optima and EasyLine series
Continuous hydrocarbon and non-methane hydrocarbon analysis
Large operating range: from low ppm to high vol%
Easy to operate
![Page 37: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/37.jpg)
AO2000 Series Analyzers
![Page 38: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/38.jpg)
AO2000 Series Analyzers
![Page 39: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/39.jpg)
AO2000 Series Analyzers
![Page 40: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/40.jpg)
![Page 41: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/41.jpg)
APPLICATIONS • Power Generation • CEMENT KILNS • boilers• furnaces • heaters• incinerators • (if it burns…. )
CEMS – 70%
• Cement Kilns • CO2 in hydrocarbons• CO in hydrogen• H2 in Cl2 • H2 in Hydrocarbons (nitrogen header..) • O2 deficiency • FID, incinerators, Hydrocarbon in water
PROCESS – 30%
• NO and NO2 measurements for CEMS (LIMAS23 and LIMAS11) • Landfill gas measurements
• CH4, CO2, O2 • GREENHOUSE GAS• CSA has a regulation
• Nitric Acid Plants • NO/NO2 ratio issues • Partner Partnering
Special Emphasis
![Page 42: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/42.jpg)
Integrated Remote Control Full Access to Gas Analyzers Functionality
![Page 43: Applied Controls Analytical System Integration 2014 National Sales Meeting CGA: Continuous Gas Analyzers Analyzer or Application – The Question Bruce Herman](https://reader038.vdocuments.us/reader038/viewer/2022110321/56649cf15503460f949c0683/html5/thumbnails/43.jpg)
Thank You For Your Time