    Plena Voice Alarm SystemApplication Note: Swimming pools

    Introduction

    The Plena Voice Alarm System is the ideal sound

    management solution or swimming pools. A voice alarm

    system or a swimming pool requires voice alarm

    unctionality as well as public address unctionality or

    regular announcements and (optional) background

    music (BGM). To ensure that all visitors in the relatively

    noisy pool area hear emergency messages, the power

    output or that zone is relatively high. Other areas,

    such as the changing rooms and oces, have lower

    power requirements. Swimming pools and other indoor

    sports and recreational acilities are typical examples o

    smaller applications with ew zones. The main priorities

    are excellent speech intelligibility and compliance with

    EN 54, ISO 7240 and EN 60849 standards, although

    music in diferent areas is optional. All necessary

    requirements and more are met by the Plena system.

    f EN 54-16, ISO 7240-16 and EN 60849 certied

    f For small- to medium-sized applications

    with up to 60 zones

    f Built-in intelligent message manager

    f Plug-and-play installation with PC congurability

    f Interconnects via CAT5 cable

  • 7/27/2019 Application Reference EnUS 1892198667

    2/4

    2

    Summary of requirements

    f Typically up to 6 zones

    f Good speech intelligibility is the main priority

    f High power requirement in the noisy pool area

    f Firemans panel by re exit

    f Call station in oce/reception

    f Additional public address unctions or

    announcements

    f Background music (BGM)

    Solution for a 6-zone system

    The Plena Voice Alarm System Controller handles

    routing to up to 6 zones, so no additional routers are

    required. The oce/reception is equipped with a call

    station plus keypad or individually addressing zones,

    while a remans panel (with overall priority) is built in

    by the emergency exit. The Plena Voice Alarm System is

    a two-channel system, so BGM can still be provided in

    zones not receiving a call.

    The Plena Voice Alarm System is designed or

    plug-and-play installation, and is easily congured

    using DIP switches or sotware or more advanced

    conguration. Once congured, the PC is disconnected.

    System interconnections are made using standard RJ45

    connectors and CAT5 cabling. Up to 255 spoken

    evacuation messages can be stored. Messages can also

    be merged to allow more exible use o pre-recorded

    messages.

  • 7/27/2019 Application Reference EnUS 1892198667

    3/4

    3

    5

    4

    3

    2

    1

    6

    Zone 1-5

    System description

    The system controller has a built-in 240 W power

    amplier, making it possible to drive up to 40

    loudspeakers with a power handling capacity o 6 W

    each. The pool area requires high-power music horn

    loudspeakers qualied or use in a high humidity

    atmosphere. The snack bar uses cabinet loudspeakers

    or music reproduction. The zones are dened as

    indicated in the table. An additional Plena Power

    Amplier is used or two-channel operation and as a

    spare amplier.

    1 Controller

    2 Remote control panel

    3 Call station

    4 Call station keypad

    5 240 W power

    amplier

    6 BGM source

    Zones

    Zone 1 Indoor pool area 5 x 30 W horn loudspeakers

    Zone 2 Childrens pool area 2 x 10 W horn loudspeakers

    Zone 3 Changing rooms 4 x 6 W ceiling loudspeakers

    Zone 4 Snack bar 4 x 6 W cabinet loudspeakers

    Zone 5 Oce 2 x 6 W cabinet loudspeakers

    Total 230 W

  • 7/27/2019 Application Reference EnUS 1892198667

    4/4

    4

    Bosch Security Systems

    To learn more about our

    product ofering, please visit

    www.boschsecurity.com

    or send an e-mail to

    [email protected]

    Bosch Security Systems, 2011

    Printed in the Netherlands

    Modications reserved

    PA-EH-en-06_4998144694_03

    Complete security solutions

    Bosch Security Systems ofers a wide range o security,

    saety, and communication solutions that are relied

    upon every day in applications and places around the

    world, rom government acilities and public venues to

    businesses, schools and homes.

    For more information about the Plena Voice Alarm

    System, please feel free to contact your nearest

    Bosch representative or visit our website:

    www.boschsecurity.com.

    Future-proof upgrade

    More zones and extra power per zone can be added by

    incorporating additional routers (up to 60 zones) and

    Plena Power Ampliers (up to 1000 W per 6 zones).

    Certied solutions

    For the installation to be ully EVAC-certied,

    loudspeakers and cabling must also conorm to the

    relevant standards. Bosch can provide training and

    certication or partner installers details available

    on request.