appendix i - · pdf filethe current edition of bs5930 together with bs en iso 14688-1:2002,...
TRANSCRIPT
APPENDIX I
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
APPENDIX I – 2011 GROUND INVESTIGATION Introduction As part of a larger ground investigation, parts of the Phase 2 site were investigated on 16 May 2011 under the supervision of a geotechnical engineer from Crossfield Consulting Limited. The ground investigation was designed and supervised by qualified and experienced geo‐environmental specialists from Crossfield Consulting Limited. Where appropriate, and as outlined below, specialist drilling/sampling equipment was procured together with trained and experienced operators. Unless otherwise indicated, sampling and logging remained the responsibility of trained staff from Crossfield Consulting Limited and field records were prepared on site, during or immediately following drilling/sampling or in situ measurements/tests. The results of in situ tests are presented on the relevant record sheets in this Appendix and the data are summarised on Figure I‐1. An exploratory hole location plan is presented as Figure I‐2. Trial Pits Seven trial pits, denoted as TP1 to TP7, were excavated by a Volvo BL71 excavator. The trial pit records from the investigation are presented in this Appendix and these records include the descriptions and depths of the strata encountered, together with sample depths, groundwater observations and other pertinent comments. In situ hand vane tests were carried out on fine‐grained soils, where appropriate, to provide undrained shear strength data representative of the tested horizon. The tests were carried out using Pilcon‐Edeco hand vane tester, with extension rods in accordance with the site health and safety method statement. With reference to the guidance published in Serota & Jangle (1972), it is noted that this instrument is calibrated and scaled to provide a direct reading of undrained shear strength, such that application of additional correction factors on the recorded measurements is not necessary. Published correlations with undrained shear strength, as measured by immediate undrained triaxial tests, indicate this hand vane tester provides measurements with a significantly lower scatter in comparison to triaxial tests, with fewer anomalous results. Specific test measurements are listed on the exploratory hole records and a summary of the test data and instrument details are presented in this Appendix. Soil Samples Samples designated for geotechnical testing were collected, stored and transported in accordance with the published requirements for the specific tests scheduled, such that moisture content and soil structure integrity was maintained, as necessary for the test requirements. Geotechnical Laboratory Testing Selected samples of the soils encountered were submitted for analysis for the following tests:
Moisture content
Atterberg Limits
pH value
Water soluble sulphate
Total sulphur
Acid soluble sulphate The analyses were carried out by Structural Soils, a UKAS accredited laboratory, and the results are presented in this Appendix.
TRIAL PIT RECORDS KEY J Disturbed Jar Sample G Soil Sample in Glass Container
g Soil Sample in Glass Vial B Disturbed Bulk Sample C "Undisturbed" CBR Mould Sample (denoted Category A: OS-TK/W in BS EN 22475-1:2006) W Water Sample cfv Undrained Shear Strength (from hand vane shear vane test)
crv Undrained Remoulded Shear Strength FVT (from hand vane shear vane test) cfv * Undrained Shear Strength from Hand Vane Shear Strength Test on block sample dug from pit by excavator
Notes: 1. All measurement values on record sheets are uncorrected, unless otherwise indicated. 2. For corrected test values, refer to report. 3. Identification and classification of strata is based on the guidance published in
the current edition of BS5930 together with BS EN ISO 14688-1:2002, BS EN ISO 14688-2:2004, BS EN ISO 14689-1:2003
4. Consistency (soft, firm, stiff etc) relates to a manual test/inspection on site (in compliance with BS EN ISO 14688-1:2002 Section 5.14)
5. Undrained shear strength (low, medium, high etc) relates to in situ or laboratory test data and the associated assessed strength of a stratum (in compliance with BS EN ISO 14688-2:2004 Section 5.3 and Table 5).
6. The density of coarse-grained soils is based on SPT N values (or equivalent Dynamic Probe test or CPT data) as outlined in BS5930 and BS EN ISO 14688-2:2004.
7. Rock strength (weak, strong etc) is based on field identification (and/or strength test data), as outlined in BS EN ISO 14689-1:2003 Table 5.
Category B Samples
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.20 0.20
1.00 1.00
1.70 1.701.80 1.80
2.50 2.50
StrataType Ref. No. Strata Description
Depth1 0.00-0.20
(TOPSOIL)
cfv 140+120140+ 2 0.20-1.00J
(WEALD CLAY)
cfv# 3 1.00-1.70
(WEALD CLAY)
4 1.70-1.80
(WEALD CLAY)
5 1.80-2.50
(WEALD CLAY)
* Levels reproduced from a topographic survey provided by the Client# Unable to push hand vane into strata
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Reddish brown medium to coarse angular gravel of very weak MUDSTONE
(1)
(2)
(3)
(5)
Hard consistency brown desiccated humic clay with rare coarse subrounded flint gravel and with rootlets
Very stiff consistency high strength orangish brown mottled brown gravelly friable CLAY. Gravel is fine to medium angular very weak mudstone with iron staining
Very stiff consistency high strength light grey mottled orangish brown friable CLAY
Sample/Test
Remarks
Depth
0.900.90
1Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B
North
66.60 m O.D.*
SamplingStrength(kN/m2)
1.40
Stable whilst excavating
None Used
Light grey mottled brown medium to coarse angular gravel and cobbles of very weak MUDSTONE
(4)
Base of Pit
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.40 0.40
0.80 0.800.85 0.85
1.60 1.60
2.10 2.10
2.40 2.40
StrataType Ref. No. Strata Description
Depth1 0.00-0.40 Hard consistency brown desiccated humic clay with rootlets
(TOPSOIL)
J 2 0.40-0.80 Very stiff consistency orangish brown mottled light grey CLAY(WEALD CLAY)
3 0.80-0.85
(WEALD CLAY)
cfv 135140+132 4 0.85-1.60
(WEALD CLAY)
5 1.60-2.10
(WEALD CLAY)
6 2.10-2.40
* Levels reproduced from a topographic survey provided by the Client
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Very stiff consistency high strength light grey mottled orangish brown very friable CLAY
Dark greyish brown medium to coarse gravel of iron-stained MUDSTONE
(1)
(2)
(4)
Dark brown fine to medium angular gravel of very weak iron-stained MUDSTONE
0.90
Sample/Test
(6)
Base of Pit
Remarks
Depth
0.70
2Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B
West
66.10 m O.D.*
SamplingStrength(kN/m2)
Stable whilst excavating
None Used
(3)
Very stiff consistency light grey mottled orangish brown very gravelly very friable CLAY. Gravel is fine to coarse angular mudstone (WEALD CLAY)
(5)
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.45 0.45
1.90 1.90
2.40 2.40
StrataType Ref. No. Strata Description
Depth1 0.00-0.45
(TOPSOIL)
cfv 101 125 100 2 0.45-1.90J
(WEALD CLAY)
3 1.90-2.40
(WEALD CLAY)
* Levels reproduced from a topographic survey provided by the Client
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Sample/Test Strength(kN/m2)
Remarks
Depth
0.800.80
3Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B
Northeast
66.65 m O.D.*
(1)
Sampling
(2)
Stable whilst excavating
None Used
(3)
Base of Pit
Orangish brown mottled light grey medium to coarse angular gravel of MUDSTONE which is locally iron-stained
Very stiff consistency dark brown desiccated humic clay with rootlets
Very stiff consistency high strength orangish brown mottled brown mottled light grey friable CLAY
…becoming gravelly below 1.0 m depth. Gravel is fine angular very weak mudstone…with a horizon of dark greyish brown medium to coarse angular gravel of iron-stained MUDSTONE between 1.10 m and 1.15 m depth
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.40 0.40
0.60 0.60
1.25 1.25
1.95 1.95
StrataType Ref. No. Strata Description
Depth1 0.00-0.40
(TOPSOIL)
2 0.40-0.60
(WEALD CLAY)
cfv 134 115 137 3 0.60-1.25J
(WEALD CLAY)
4 1.25-1.95 Brown medium to coarse angular gravel of MUDSTONE(WEALD CLAY)…locally iron-stained at surface of horizon…with MUDSTONE cobbles below 1.8 m depth
* Levels reproduced from a topographic survey provided by the Client
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Stable whilst excavating
None Used
SamplingStrength(kN/m2)
(3)
4Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B
Northeast
66.50 m O.D.*
Remarks
Depth
(4)
Base of Pit
Sample/Test
0.901.20
Very stiff consistency high strength light grey mottled orangish brown friable CLAY
(1)
(2)
Hard consistency dark greyish brown desiccated humic clay with roots and rootlets
Very stiff consistency orangish brown mottled light grey friable CLAY with rootlets
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.30 0.30
1.20 1.20
2.10 2.10
StrataType Ref. No. Strata Description
Depth1 0.00-0.30
(TOPSOIL)
cfv 140+140+140+ 2 0.30-1.20J
(WEALD CLAY)
3 1.20-2.10
(WEALD CLAY)
* Levels reproduced from a topographic survey provided by the Client
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Remarks
Depth
1.051.05
5Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B
Southwest
67.15 m O.D.*
Strength(kN/m2)
Sample/TestSampling
(1)
Base of Pit
Stable whilst excavating
None Used
(2)
(3)
Light grey mottled brown fine to coarse angular gravel of MUDSTONE
…with a dark brown iron-stained horizon between 1.3 m and 1.5 m depth
Very stiff consistency greyish brown desiccated humic clay with roots and rootlets
Very stiff consistency high strength orangish brown mottled light grey very friable CLAY with roots and rootlets to 0.6 m depth
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.35 0.35
1.90 1.90
2.50 2.50
StrataType Ref. No. Strata Description
Depth1 0.00-0.35
(TOPSOIL)
cfv 122140+140+ 2 0.35-1.90J
(WEALD CLAY)
3 1.90-2.50
(WEALD CLAY)
* Levels reproduced from a topographic survey provided by the Client
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Stable whilst excavating
None Used
SamplingStrength(kN/m2)
Sample/Test
6Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B
West
65.60 m O.D.*
Remarks
Depth
0.550.70
Base of Pit
(1)
(2)
(3)
Very stiff to hard consistency greyish brown humic clay with rootlets
Very stiff consistency high strength light grey mottled orangish brown friable CLAY
…becoming gravelly CLAY below 1.5 m depth. Gravel is fine to coarse angular very weak mudstone
Brown fine to coarse angular gravel and cobbles of very weak to weak to medium strong MUDSTONE
…becoming greyish brown cobbles of medium strong MUDSTONE below 2.3 m depth
Project: London Road, Crawley Trial Pit
Sheet 1 of 1
Bearing: Shoring: Job No. CCL02061
Stability: Date: 16/05/2011
Plant: Volvo BL71 A C Water: None encountered
Logged by: CJW
Checked by:
Face A: Face B: Face C: Depth
0.35 0.35
2.00 2.00
2.30 2.30
StrataType Ref. No. Strata Description
Depth1 0.00-0.35
(TOPSOIL)
cfv 140+140+137 2 0.35-2.00J
(WEALD CLAY)
3 2.00-2.30
(WEALD CLAY)…mudstone becomes medium strong below 2.15 m depth
* Levels reproduced from a topographic survey provided by the Client
Symbols and abbreviations are explained on the accompanying key. All linear dimensions are in metres unless otherwise stated.
Sample/Test Strength(kN/m2)
…with fine to medium angular gravel of very weak mudstone below 1.3 m depth
Remarks
Depth
0.700.70
Sampling
7Crossfield Consulting LimitedTrial Pit Plan
Depth
Co-ordinates:
Ground Level: B Stable whilst excavating
None UsedSouth
64.95 m O.D.*
(3)
Light grey mottled orangish brown fine to coarse angular gravel and cobbles of very weak to weak to medium strong MUDSTONE
(1)
(2)
Hard consistency greyish brown desiccated humic clay with rootlets
Very stiff to hard consistency high strength orangish brown mottled light grey CLAY
Base of Pit
NOTE:
June 2011CCL02061.BM 72
Crossfield Consulting LimitedLondon Road, Crawley
UNDRAINED SHEAR STRENGTH vs DEPTH
Data from in situ hand vane tests in fine-grained soils.
FIGURE I-1
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
Undrained Shear Strength (kN/m2)
Depth (m
)
CROSSFIELD CONSULTING LIMITEDLONDON ROAD, CRAWLEY
(m) (%) (%) (%) (g/l SO4)
TP2 0.70 - 8.3 0.02 <0.02 0.03TP4 1.20 - 7.9 0.02 <0.02 0.03TP5 1.05 - 8.2 <0.01 <0.02 0.02TP7 0.70 - 8.4 0.02 <0.02 <0.01TP8 0.75 - 8.3 <0.01 <0.02 <0.01
TP10 1.10 - 7.7 0.01 0.03 0.09TP11 1.10 - 5.3 0.06 0.05 0.05TP12 0.85 - 8.4 0.01 <0.02 0.04
Certificate No: 581647 Page 3 of 3
Acid Soluble
Sulphate
Total Sulphur
Organic Matter
Water Soluble
SulphateBorehole Depth pH Value
Note: This testing was not performed by Structural Soils Ltd and was subcontracted
SUMMARY OF pH VALUE, SULPHUR & SULPHATE
Dra
wn
by:
PK
Dat
e: 3
0/04
/201
1T
empl
ate
Issu
e:
2
File
nam
e: 5
8164
7 /
CH
EM
ICA
L /
01_S
P.X
LS
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
FIGURE I‐2
EXPLORATORY HOLE LOCATION PLAN
Scale 1: 2,000
Reproduced from a topographic survey provided by the Client
TP7
TP4
TP6
TP3
TP5
TP1
TP2
APPENDIX II
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
APPENDIX II – SUPPLEMENTARY GROUND INVESTIGATION Introduction This Appendix and Appendix I, together with Sections 2 to 4 of the report, forms the Ground Investigation Report for the development described in the report, in compliance with the requirements of BS 5930:1999+A2:2010, BS EN1997‐1:2004(2007) and BS EN1997‐2:2007(2007). The site operations were carried out on 14 October 2013 under the supervision of a geotechnical engineer from Crossfield Consulting Limited. The scope and rationale for the design of the investigation is presented in Table II‐1. The ground investigation was designed and supervised by qualified and experienced geo‐environmental specialists from Crossfield Consulting Limited. Where appropriate, and as outlined below, specialist drilling/sampling equipment was procured together with trained and experienced operators. Unless otherwise indicated, sampling and logging remained the responsibility of trained staff from Crossfield Consulting Limited and field records were prepared on site, during or immediately following drilling/sampling or in situ measurements/tests. The results of in situ tests are presented on the relevant record sheets in this Appendix and the data are summarised on Figure II‐1. Details of any correction factors used in processing the test results are presented in the summary figures. An exploratory hole location plan is presented as Figure II‐2. Trial Pits Four trial pits, denoted as TP201 to TP204, were excavated by a JCB 3CX eco excavator. The trial pit records from the investigation are presented in this Appendix and these records include the descriptions and depths of the strata encountered, together with sample depths, groundwater observations and other pertinent comments. In situ hand vane tests were carried out on fine‐grained soils, where appropriate, to provide undrained shear strength data representative of the tested horizon. The tests were carried out using Pilcon‐Edeco hand vane tester, with extension rods in accordance with the site health and safety method statement. With reference to the guidance published in Serota & Jangle (1972), it is noted that this instrument is calibrated and scaled to provide a direct reading of undrained shear strength, such that application of additional correction factors on the recorded measurements is not necessary. Published correlations with undrained shear strength, as measured by immediate undrained triaxial tests, indicate this hand vane tester provides measurements with a significantly lower scatter in comparison to triaxial tests, with fewer anomalous results. Specific test measurements are listed on the exploratory hole records and a summary of the test data and instrument details are presented in this Appendix. Soil Samples Samples designated for geotechnical testing were collected, stored and transported in accordance with the published requirements for the specific tests scheduled, such that moisture content and soil structure integrity was maintained, as necessary for the test requirements.
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
Geotechnical Laboratory Testing The rationale for the geotechnical laboratory testing is set out in the Table II‐2. Selected samples of the soils encountered were submitted for analysis for the following tests:
Moisture content
Atterberg Limits
pH value
Water soluble sulphate The analyses were carried out by Chemtest and GEO Site & Testing Services Limited (GSTL), UKAS accredited laboratories, and the results are presented in this Appendix.
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
TABLE II‐1
RATIONALE FOR THE DESIGN OF THE GROUND INVESTIGATION
The scope of the ground investigation was designed with reference to the published geology and ground conditions indicated in the desk study information. In addition, reference was also made to the factual records within Appendix I. It is noted that the investigation works were constrained by access restrictions, in particular the presence of mature trees in the western margin of the site. In compliance with the guidance published in BS EN 1997‐2:2007, the ground investigation was designed to verify the preliminary ground model, established from the desk study information and to characterise the ground conditions within influencing distance of the proposed structures. In this regard, the exploratory holes were targeted within relevant areas of the site to provide information on the strata profile down to competent materials. With reference to the desk study information and the support requirements of the proposed development, it is evident that adequate support is provided by the strata that continue below the depths of the exploratory holes. In compliance with the guidance published in BS 10175:2011 and BS 5930:1999+A2:2010, the layout of the exploratory holes and sampling regime also considers the Conceptual Site Model and potential pollutant linkages, such that the spatial arrangement of the investigation provides the necessary information to support a risk assessment of the identified potential pollutant linkages.
Exploratory Hole and Technique
Rationale for Hole Location Depth (m) Sampling/In Situ Testing and Monitoring
TP201 to TP204
TP201 to TP203 were located in an area which was not part of the site boundary in 2011. TP204 was located in an area which wasn’t investigated in 2011 to provide additional coverage of the site
0.00‐2.20/2.40 Soil samples were collected from likely founding depth
Key TP X Machine dug trial pit
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
TABLE II‐2
RATIONALE FOR THE GEOTECHNICAL TESTING SUITE
Exploratory Hole and Sample
Selection Criteria Geotechnical Tests
TP201 1.00 m TP202 1.00 m TP203 0.60 m TP204 0.70 m
Classification and foundation design Moisture content Atterberg Limits
TP201 1.00 m TP202 1.00 m TP203 0.60 m TP204 0.70 m
Foundation concrete design classification pH Water soluble sulphate
TRIAL PIT RECORDS KEY J Disturbed Jar Sample G Soil Sample in Glass Container
g Soil Sample in Glass Vial B Disturbed Bulk Sample C "Undisturbed" CBR Mould Sample (denoted Category A: OS‐TK/W in BS EN 22475‐1:2006) W Water Sample cfv Undrained Shear Strength (from hand vane shear vane test)
crv Undrained Remoulded Shear Strength FVT (from hand vane shear vane test) cfv * Undrained Shear Strength from Hand Vane Shear Strength Test on block sample dug from pit by excavator
Notes: 1. All measurement values on record sheets are uncorrected, unless otherwise indicated. 2. For corrected test values, refer to report. 3. Identification and classification of strata is based on the guidance published in
the current edition of BS5930 together with BS EN ISO 14688‐1:2002, BS EN ISO 14688‐2:2004, BS EN ISO 14689‐1:2003
4. Consistency (soft, firm, stiff etc.) relates to a manual test/inspection on site (in compliance with BS EN ISO 14688‐1:2002 Section 5.14)
5. Undrained shear strength (low, medium, high etc.) relates to in situ or laboratory test data and the associated assessed strength of a stratum (in compliance with BS EN ISO 14688‐2:2004 Section 5.3 and Table 5).
6. The density of coarse‐grained soils is based on SPT N values (or equivalent Dynamic Probe test or CPT data) as outlined in BS5930 and BS EN ISO 14688‐2:2004.
7. Rock strength (weak, strong etc.) is based on field identification (and/or strength test data), as outlined in BS EN ISO 14689‐1:2003 Table 5.
Category B Samples
Hole Ref.
Project 1 of 1
Date Job No.
Shoring 65.5 m OD
Stability
CJW
B Water
0.20 0.20
1.30 1.30
2.40 2.40
Sampling Strata
Type Strength Ref. No. Strata Description
(kN/m2) Depth
1 0.00‐0.20
cfv 72,75,80 2 0.20‐1.30
JJ
…becoming very stiff consistency light grey mottled orangish brown friable CLAY/SILT with depth
3 1.30‐2.40
Remarks Notes
1. All logging and sampling in accordance with BS 5930:1999+A2:2010
2. Symbols and abbreviations are explained on the accompanying key
3. All linear dimensions are in metres unless otherwise stated
Trial Pit Record SheetPhase 2, Hydehurst Lane, Northgate, Crawley
Bearing:
Plant
Trial Pit
West
JCB 3CX eco
14/10/2013
None used
TP 201
Logged by Logged on
site during
excavation
Ground Level
Co‐ordinates
CCL02427
Sheet
Level estimated from a topographic survey provided by the Client
0.60
1.00
Checked byPlan
A
C
Face B Face CFace A
Stable whilst excavating
None encountered
Depth
Depth
Sample/Test
Grass over dark brown humic clay with roots and rootlets
(TOPSOIL)
Stiff consistency light greyish brown mottled orangish brown CLAY
(WEALD CLAY)
…becoming light grey mottled brown with depth
Depth
…becoming extremely weak MUDSTONE gravel below 1.2 m depth
Weak brown MUDSTONE ‐ excavates as medium to coarse angular gravel
(WEALD CLAY)
Base of Pit
(1)
(2)
(3)
Crossfield CONSULTINGThe Granary, White Hall Farm, Long Itchington, Warwickshire, CV47 9PU, t: 01926 815678, e: mail@crossfield‐consulting.co.uk
Hole Ref.
Project 1 of 1
Date Job No.
Shoring 66.0 m OD
Stability
CJW
B Water
0.45 0.45
1.20 1.20
2.30 2.30
Sampling Strata
Type Strength Ref. No. Strata Description
(kN/m2) Depth
1 0.00‐0.45
JJ 2 0.45‐1.20
3 1.20‐2.30 Weak light grey mottled brown MUDSTONE ‐ excavates as medium to coarse angular gravel
Remarks Notes
1. All logging and sampling in accordance with BS 5930:1999+A2:2010
2. Symbols and abbreviations are explained on the accompanying key
3. All linear dimensions are in metres unless otherwise stated
14/10/2013 CCL02427
Trial Pit Record Sheet TP 202Phase 2, Hydehurst Lane, Northgate, Crawley Sheet
Bearing: Northwest None used Ground Level
Plant JCB 3CX eco Stable whilst excavating Co‐ordinates
Depth
Trial Pit A Logged by Logged on
site during
excavationPlan None encountered Checked by
C
Depth Face A Face B Face C
Sample/Test
Depth
Brambles over firm to stiff consistency dark grey humic clay with roots and rootlets
(TOPSOIL)
1.00 Hard consistency orangish brown desiccated CLAY with roots
(WEALD CLAY)
…becoming light grey mottled orangish brown below 0.6 m depth
(WEALD CLAY)
…becoming dark brown and moderately strong below 1.9 m depth
Level estimated from a topographic survey provided by the Client
(1)
(2)
(3)
Base of Pit
Crossfield CONSULTINGThe Granary, White Hall Farm, Long Itchington, Warwickshire, CV47 9PU, t: 01926 815678, e: mail@crossfield‐consulting.co.uk
Hole Ref.
Project 1 of 1
Date Job No.
Shoring 66.5 m OD
Stability
CJW
B Water
0.40 0.40
1.30 1.30
1.50 1.50
2.30 2.30
Sampling Strata
Type Strength Ref. No. Strata Description
(kN/m2) Depth
1 0.00‐0.40
cfv 3 x 140+ 2 0.40‐1.30
JJ
3 1.30‐1.50 Moderately strong dark brown MUDSTONE ‐ excavates as medium to coarse angular gravel
4 1.50‐2.30 Extremely weak light grey mottled brown MUDSTONE ‐ excavates as fine to coarse angular gravel
Remarks Notes
1. All logging and sampling in accordance with BS 5930:1999+A2:2010
2. Symbols and abbreviations are explained on the accompanying key
3. All linear dimensions are in metres unless otherwise stated
14/10/2013 CCL02427
Trial Pit Record Sheet TP 203Phase 2, Hydehurst Lane, Northgate, Crawley Sheet
Bearing: Northwest None used Ground Level
Plant JCB 3CX eco Stable whilst excavating Co‐ordinates
Depth
Trial Pit A Logged by Logged on
site during
excavationPlan None encountered Checked by
C
Depth Face A Face B Face C
Sample/Test
Depth
Brambles over dark greyish brown desiccated humic clay with roots and rootlets
(TOPSOIL)
0.60 Hard consistency light brown mottled orangish brown desiccated CLAY with roots
0.60 (WEALD CLAY)
…becoming light grey mottled orangish brown with depth
(WEALD CLAY)
(WEALD CLAY)
Level estimated from a topographic survey provided by the Client
Base of Pit
(1)
(2)
(3)
(4)
Crossfield CONSULTINGThe Granary, White Hall Farm, Long Itchington, Warwickshire, CV47 9PU, t: 01926 815678, e: mail@crossfield‐consulting.co.uk
Hole Ref.
Project 1 of 1
Date Job No.
Shoring 65.5 m OD
Stability
CJW
B Water
0.25 0.25
1.10 1.10
2.20 2.20
Sampling Strata
Type Strength Ref. No. Strata Description
(kN/m2) Depth
1 0.00‐0.25
cfv 74,94,127 2 0.25‐1.10
JJ
3 1.10‐2.20
Remarks Notes
1. All logging and sampling in accordance with BS 5930:1999+A2:2010
2. Symbols and abbreviations are explained on the accompanying key
3. All linear dimensions are in metres unless otherwise stated
14/10/2013 CCL02427
Trial Pit Record Sheet TP 204Phase 2, Hydehurst Lane, Northgate, Crawley Sheet
Bearing: North None used Ground Level
Plant JCB 3CX eco Stable whilst excavating Co‐ordinates
Depth
Trial Pit A Logged by Logged on
site during
excavationPlan None encountered Checked by
C
Depth Face A Face B Face C
Sample/Test
Depth
Grass over soft to firm consistency greyish brown humic clay with roots and rootlets
(TOPSOIL)
0.70 Very stiff consistency light greyish brown mottled orangish brown CLAY
0.70 (WEALD CLAY)
(WEALD CLAY)
…becoming weak and brown mottled light grey below 2.0 m depth
Level estimated from a topographic survey provided by the Client
(1)
(2)
(3)
Base of Pit
Extremely weak orangish brown mottled light grey MUDSTONE ‐ excavates as fine to coarse
angular gravel
Crossfield CONSULTINGThe Granary, White Hall Farm, Long Itchington, Warwickshire, CV47 9PU, t: 01926 815678, e: mail@crossfield‐consulting.co.uk
Phase 2, Hydehurst Lane, Northgate, Crawley
CCL02427.BS86October 2013
FIGURE II‐1
Undrained Shear Strength (cu) Profile
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
0 25 50 75 100 125 150
Dep
th (m)
Cu Value (kN/m2)
2011 Investigation 2013 Investigation
Depot Road
Newmarket
CB8 0AL
Tel: 01638 606070
Please find enclosed the results of analysis for the samples received 17 Oct 2013.
Yours sincerely
Keith Jones, Technical Manager
Newmarket • Tamworth • Glasgow
Registered in England & Wales - Registration Number 6511736 - Registered Office: 11 Depot Road Newmarket Suffolk CB8 0AL
24 October 2013
Dear Caroline Walliss
Test Report Number 242107
Your Project Reference CCL02427- Phase 2, London Road, Crawley
Crossfield Consulting Ltd
The Granary
White Hall Farm
Long Itchington, Warwickshire
CV47 9PU
All soil samples will be retained for a period of one month and all water samples will be retained for 7 days following the date of the test report. Should you require an extended retention period then please detail your requirements in an email to [email protected]. Please be aware that charges may be applicable for extended sample storage. If you require any further assistance, please do not hesitate to contact the Customer Services team.
Notes to accompany report: • The in-house procedure is employed to identify materials and fibres in soils • The sample is examined by stereo-binocular and polarised light microscopy • Sample size is reduced by coning and quartering to obtain a representative sub-sample if necessary • The bulk identification is in accordance with the requirements of the analyst guide (HSG 248) • Samples associated with asbestos are retained for six months • The results relate only to the items tested as supplied by the client • Comments or interpretations are beyond the scope of UKAS accreditation
LABORATORY TEST REPORT
Crossfield Consulting Ltd
The Granary
White Hall Farm
Long Itchington, Warwickshire
CV47 9PU
FAO Caroline Walliss
MISC_PHYS
242107 242107 242107 242107
AJ30456 AJ30457 AJ30458 AJ30459
TP201 TP202 TP203 TP204
17/10/2013 17/10/2013 17/10/2013 17/10/2013
1.00m 1.00m 0.60m 0.70m
SOIL SOIL SOIL SOIL
SOP Determinand Cas No Units *
2030 Moisture % M 19.6 11.1 14.5 18
2030 Stones content (>50mm) % M <0.02 <0.02 <0.02 <0.02
2040 Soil colour M brown brown brown brown
2040 Soil texture M clay clay clay clay
2040 Other material M none none none none
SO4_PH
242107 242107 242107 242107
AJ30456 AJ30457 AJ30458 AJ30459
TP201 TP202 TP203 TP204
17/10/2013 17/10/2013 17/10/2013 17/10/2013
1.00m 1.00m 0.60m 0.70m
SOIL SOIL SOIL SOIL
SOP Determinand Cas No Units *
2010 pH M 7.4 7.2 7.3 8
2120 Sulfate (2:1 water soluble) as SO4 14808798 g l-¹ M 0.03 <0.01 <0.01 <0.01
Depth
Matrix
Results of analysis of sample
received 16/10/2013
Report Date
24/10/2013
Matrix
Login Batch No
Chemtest LIMS ID
Sample ID
Sample No
Sampling Date
Login Batch No
Chemtest LIMS ID
Sample ID
Sample No
Sampling Date
Depth
All tests undertaken between 17/10/13 and 22/10/13
This report should be interpreted in conjuction with the notes on the accompanying cover page
* Accreditation status
Report Page 2 of 2
LIMS Sample ID Range AJ30456 to AJ30459
2788
LaboratoryReport
GEO Site & Testing Services Ltd
Contract Number: 21146
Notes: Observations and Interpretations are outside the UKAS Accreditation* - denotes test included in laboratory scope of accreditation# - denotes test carried out by approved contractor
This certificate is issued in accordance with the accreditation requirements of the United Kingdom Accreditation Service. The results reported herein relate only to the material supplied to the laboratory. This certificate shall not be reproduced in full, without the prior written approval of the laboratory.
Approved Signatories:Alex Wynn (Associate Director) - Benjamin Sharp (Contracts Manager) - Emma Williams (Office Manager)Paul Evans (Quality/Technical Manager) - Vaughan Edwards (Managing Director)
Page 1 of 1GEO Site & Testing Services LtdUnit 4, Heol Aur, Dafen Ind Estate, Dafen, Llanelli, Carmarthenshire SA14 8QNTel: 01554 784040 Fax: 01554 784041 [email protected] geo.uk.com
Client's Reference: CCL02427 PO7937 Report Date: 29-10-2013
Client Crossfield ConsultingThe GranaryWhite Hall FarmLong ItchingtonWarwickshireCV47 9PU
Contract Title: Phase 2, London Road, CrawleyFor the attention of: Caroline Walliss
Date Received: 17-10-2013Date Commenced: 17-10-2013
Date Completed: 29-10-2013
Test Description Qty
Moisture Content1377 : 1990 Part 2 : 3.2 - UKAS *
4.0
4 Point Liquid & Plastic Limit (LL/PL)1377 : 1990 Part 2 : 4.3 & 5.3 - UKAS *
4.0
GEO/005
Test Report: Method of the Determination of the plastic limit and plasticity indexBS 1377 : Part 2 : 1990 Method 5
Client ref: CCL02427
Location:
Contract Number: 21146-171013
Hole/ Moisture Liquid Plastic Plasticity %
Sample Sample Content Limit Limit Index Passing Remarks
Number Type % % % % .425mm
Cl. 3.2 Cl. 4.3/4.4 Cl. 5. Cl. 6.
TP201 1.00 26 51 22 29 100 CH High Plasticity
TP202 1.00 12 45 19 26 100 CI Intermediate Plasticity
TP203 0.60 19 53 25 28 100 CH High Plasticity
TP204 0.70 23 56 25 31 100 CH High Plasticity
Symbols: NP : Non Plastic # : Liquid Limit and Plastic Limit Wet Sieved
Checked By Approved By:
Date Approved: 29.10.13
Phase 2, London Road, Crawley
PLASTICITY CHART FOR CASAGRANDE CLASSIFICATION.
BS 5930:1999+A2:2010
Depth
m
0
10
20
30
40
50
60
70
80
90
0 20 40 60 80 100 120
Pla
stic
ity
Inde
x (%
)
Liquid Limit (%)
CE CH CI CV CL
ME MV MH MI ML
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
FIGURE II‐2
EXPLORATORY HOLE LOCATION PLAN
Scale 1: 1,000
Reproduced from a topographic survey provided by the Client
TP4
TP203
TP7TP1
TP2
TP3
TP6TP5
Key
2011 Trial Pits
2013 Trial Pits
TP1
TP204
TP202
TP201
TP1
APPENDIX III
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
APPENDIX III – BASIS OF GEOTECHNICAL ASSESSMENT FOR FOUNDATIONS Geotechnical Design Category of Structure: 2 Design Working Life: Standard building structure (50 years) Design Approach: 1 1. Geotechnical Model On the basis of the ground investigation data, the following model of the ground conditions is considered appropriate for foundation design purposes:
Depth (m)
General Description of Strata
(and classification)
Parameter
Characteristic Value & Units
Remarks
0.00 to 0.35 Topsoil
15 kN/m3 BS 8002 (1994)
0.35 to 1.50
Very stiff consistency high strength orangish brown mottled light grey friable clay with mudstone gravel (Weald Clay)
cu øu
Modified PI
20 kN/m3
125 kN/m2 0° 23%
BS 8002 (1994) Based on site data Medium volume‐change potential NHBC (2013)
1.50 to >2.90
Fine to coarse angular gravel of very weak to moderately strong mudstone (Weald Clay)
UCS1
22 kN/m3
5 MPa BS 8002 (1994) Estimated from site data
Note: 1. UCS = Unconfined Compressive Strength Characteristic Depth to Groundwater (or groundwater level): >3.0 m Reference should be made to Sections 7 – 8 of the report for an assessment of overall ground stability, seismic risk, combined failure of the structure/ground, excessive settlements and potential soil‐volume changes (including heave). 2. Imposed Actions from Proposed Structure The following are generic values, based on the development proposed, as described in the report. In compliance with BS EN 1997‐1:2004, final designs should include consideration of the calculated imposed loads. Preliminary Values, for appraisal purposes: Imposed Load on Foundations: It is understood that typical column loads of the proposed building will be around 600 kN for perimeter columns and 1200 kN for internal columns.
Phase 2, Hydehurst Lane, Northgate, Crawley CCL02427.BS86 October 2013
Serviceability Limit Values Maximum Total Settlement: 25 mm Maximum Differential Settlement 15 mm If the structural loadings or serviceability criteria for the proposed structure vary significantly from the values presented above, further assessment will be required. 3. Geometry of Proposed Foundation Footing Width (assumed for assessment): 3 m maximum Footing Depth (assumed for assessment): Minimum 0.9 m 4. Shallow Foundations In assessing the allowable bearing pressures below structural foundations, a number of methods are used, as outlined below. 4.1. Fine Grained Soils Where the foundations are to be placed on these soils, the ultimate bearing capacity has been estimated using the method proposed by Terzaghi (1943) using total stress parameters. Partial factors have been considered in this assessment, in accordance with BS EN 1997‐1:2004 and the relevant National Annex. The recommended Nett Allowable Bearing Pressure is based on a value less than 0.3 times the ultimate bearing capacity and, therefore, the serviceability limit state will be satisfied where imposed serviceability loading is not greater than this value. 4.2. Rock Where foundations are to be placed on rock, the presumed bearing resistance is obtained from BS EN 1997‐1:2004 Figure G.1. As predicted settlement <0.5% of foundation width, a detailed serviceability limit calculation is not necessary.