  • CITY OF ST. ALBERTENGINEERING STANDARD

    DRAWINGSAPRIIL 2014

    APPENDIX A

  • Municipal Engineering Standards Drawing Index

    STANDARD DRAWINGS

    Drawing No. Drawing Name

    Revision (M/D/Y)

    PDF Page No.

    3.1 Depth of Cover & Vertical Separation Between Mains 04/23/14 6 3.2 9.0m Local (Residential) 02/25/15 7 3.3 11.0m Minor Collector (Residential & Commercial) 02/25/15 8 3.4

    12.0m Major Collector (Residential & Commercial) 02/25/15 9

    3.5 15.0m Undivided Arterial 02/25/15 10 3.6 20.5m Divided Arterial 02/25/15 11 3.7 Left Blank Intentionally 04/01/13 12 3.8 Left Blank Intentionally 04/01/13 13 3.9 Left Blank Intentionally 04/01/13 14 3.10 Cul-de-Sac Bulb – No Walkway 04/01/13 15 3.11 Cul-de-Sac Bulb – Monolithic Sidewalk 04/01/13 16 3.12 6.0m P.U.L. - Utility Easement 04/01/13 17 3.13 P.U.L. Section 04/01/13 18 3.14 Driveway Residential Crossing - 2 Car Garage (Max 7.5m) 04/15/15 19 3.15

    Driveway Residential Crossing - 3 Car Garage (Max 7.5m) 04/15/15 20

    3.16 Driveway Residential Crossing – For Small Lots (

  • Municipal Engineering Standards Drawing Index

    Drawing No. Drawing Name

    Revision (M/D/Y)

    PDF Page No.

    3.29

    Road Lines Template 04/01/13 36 3.30

    Pedestrian Crosswalk and Stop Bar Detail 04/01/13 37

    3.31

    11.0m Wide Collector Zebra Stripe Crosswalk Detail 04/01/13 38 3.32

    Arterial Zebra Stripe Crosswalk Detail 04/01/13 39

    3.33

    Stop Box Pavement Marking 04/01/13 40 3.34

    Crosswalks at Signalized Intersections 04/01/13 41

    3.35

    Lane and Lead In Lines 04/01/13 42 3.36

    Lateral Pavement Markings 04/01/13 43

    3.37 Crosswalks at Intersections, With Pedestrian Actuated Signals 04/01/13 44

    3.38 Crosswalks at Intersections, Midblock and T-Intersection with Pedestrian Flashers or Signs 04/01/13 45

    3.39 Guide Lines 04/01/13 46 3.40 Continuity Lines 04/01/13 47 3.41 Spacing of Turn Arrows in Forced Left Turn Lane 04/01/13 48 3.42 Spacing of Turn Arrows in Forced Right Turn Lane 04/01/13 49 3.43

    Spacing of Turn Arrows 04/01/13 50

    3.44 Two Lane Exit Forced Right with Through Right Option 04/01/13 51 3.45 Two Lane Exit Only on Right 04/01/13 52 3.46 Pavement Edge Lines at Yields and Merge Entrances 04/01/13 53 3.47 Merging / Diverging Gore Details 04/01/13 54 3.48 Merge Area 04/01/13 55 3.49 Left Turn Bay Marking With Slab-on Island 04/01/13 56 3.50 Diverge Area Opposing Flow 04/01/13 57 3.51

    Diverge Area Common Flow 04/01/13 58

    3.52

    Single Arrow 04/01/13 59 3.53

    Double Arrow 04/01/13 60

    3.54

    Merging Arrow 04/01/13 61 3.55

    Handicap Symbol 04/01/13 62

    4.1

    Extruded Concrete Sidewalk – Standard Detail 04/01/13 63 4.2 Typical Intersection Curb Ramp and Boulevard Ramp 04/01/13 64 4.3 Layout of Crosswalks and Ramps at Urban Intersections 04/01/13 65

    4.4 Sidewalk Ramp for Wheelchairs and Bicycles on Corner (Type C) 04/01/13 66

  • Municipal Engineering Standards Drawing Index

    Drawing No. Drawing Name

    Revision (M/D/Y)

    PDF Page No.

    4.5 Sidewalk Ramp for Wheelchairs or Bicycles on Corner (Type A) 04/01/13 67

    4.6

    Intersection Islands – Minimum Size 04/01/13 68 4.7

    Left Blank Intentionally 04/01/13 69

    4.8

    Roll Face Curb and Gutter (Mountable) 04/01/13 70 4.9

    150mm Standard Reverse Curb 250mm Gutter 04/01/13 71

    4.10 200mm Standard Curb with 300mm Gutter – REHAB Only 04/01/13 72 4.11

    200mm Standard Curb & 500mm Gutter 04/01/13 73

    4.12 Standard Barrier Curb & Curb Crossing 04/01/13 74 4.13 Drop Curb 04/01/13 75 5.1 Typical Hydrant Connection & Valve Placement 05/13/15 76

    5.2A 25mm Residential Water Service Connection (“CC”) 06/22/15 77 5.2B 50mm Residential Water Service Connection (“CC”) 06/22/15 78 5.2C Typical TVS Connection (Tapping Valve Sleeve) 05/13/15 79 5.3A Typical Service Location (6.5m boulevard) 06/12/15 80 5.3B Typical Service Connection (4.5m boulevard) 06/12/15 81 5.4 Typical Water Main Valve – TYPE A 06/22/15 82 5.5 Trenching Detail 04/01/13 83 5.6 Types of Pipe Bedding and Pipe Zone Backfill 04/01/13 84 5.7 Concrete Thrust Block Details for Water Mains 04/01/13 85 5.8 Augured Service (Residential) - Installation Details 04/01/13 86 5.9 Cathodic Protection for Watermain Fittings 04/01/13 87 5.10 Cathodic Protection for Hydrants 04/01/13 88 5.11 Cathodic Protection for Typical Water Service Connection 04/01/13 89 6.1 Standard 1200mm Diameter Manhole 10/03/14 90 6.2 Typical Perched Manhole for Pipes 600mm – 1050mm DIA 10/03/14 91 6.3 T-Riser Manhole 04/01/13 92 6.4 External Drop Manhole 04/01/13 93 6.5 Internal Drop Manhole 04/01/15 94 6.6 Sanitary Sewer Service with Riser 04/01/15 95 6.7 Floating Type Manhole Frame & Cover F-80 10/03/14 96

    6.8 Floating Type Manhole Frame and Cover with Gasket Seal F-90 10/03/14 97

    6.9 Standard F-39 Manhole Cover Plate 10/03/14 98

  • Municipal Engineering Standards Drawing Index

    Drawing No. Drawing Name

    Revision (M/D/Y)

    PDF Page No.

    7.1 Typical 900mm Diameter Catch Basin with K-7 Frame and Cover 10/03/14 99

    7.2 900mm Diameter Catch Basin with F-51 Two-Piece Frame & Cover 04/23/14 100

    7.3 1200mm Diameter Catch Basin Manhole with F-38/F39 Frame and Cover 10/03/14 101

    7.4 Typical Catch Basin Cover Details 04/01/13 102

    7.5 K-7 Type Catch Basin 04/01/13 103 7.6 Typical Sump Pump Connection 04/01/13 104 7.7 Typical Clean Out 04/01/13 105

    7.8A 3.0m Drainage Easement – Concrete Swale 500mm 06/12/15 106

    7.8B 3.0m Drainage Easement – High Back Concrete Swale 750mm 06/12/15 107

    7.8C 3.0m Drainage Easement – Concrete Swale 1000mm 06/12/15 108

    7.9 Lot Grading 03/17/14 109 7.10 Typical Walk-Out Basement - Lot Grading 04/01/13 110 7.11 Cross Section for Storm Water Retention Lake 04/01/13 111 7.12 Wick Drain Connection to Catch Basin 04/01/13 112

  • WATERMAIN

    PRIMARYPOWER

    CABLE TVTELEPHONE

    GAS

    SANITARYSEWER

    GAS

    STORMSEWER

    TYPICAL ROAD SECTION

    ROADWAY

    0.3 0.3

    0.5 0.5

    0.3 0.3

    SANITARY STORM WATER

    SANITARY STORM

    WATER WATER

    STORMSANITARY

    MINIMUM DEPTH OF COVER

    MINIMUM VERTICAL SEPARATION

    NOTES1. ALL DIMENSIONS IN METRES.2. UNDER NORMAL CONDITIONS, WATER MAINS SHALL CROSS ABOVE SEWERS WITH A SUFFICIENT VERTICAL

    SEPARATION TO ALLOW FOR PROPER BEDDING AND STRUCTURAL SUPPORT OF THE WATER AND SEWER MAINS.3. WHERE IT IS NECESSARY FOR THE WATERMAIN TO CROSS BELOW THE SEWER, THE WATERMAIN SHALL BE

    PROTECTED BY THE FOLLOWING: i. A VERTICAL SEPARATION OF AT LEAST 0.5m FROM OUTER DIAMETER (O.D.) OF THE WATERMAIN PIPE CROWN

    TO THE OUTER DIAMETER (O.D.) OF THE SEWER INVERT; ii. STRUCTURAL SUPPORT OF THE SEWER TO PREVENT EXCESSIVE JOINT DEFLECTION AND SETTLING; AND iii. CENTERING OF THE LENGTH OF WATERMAIN AT THE POINT OF CROSSING SO THAT THE JOINTS ARE

    EQUIDISTANT FROM THE SEWER BEING CROSSED.

    1.01.8

    2.65

    2.60

    1.00.3

    0.3

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    23/04/14

    BOTTOM OF ROAD

    WATERSANITARYSTORM

    CROSSING DUCT

    L.O.G.

    MIN1.5

    1.0

    PRIMARYPOWER

    CABLE TVTELEPHONE

    FINISHED GROUND FINISHED GROUND

    ⅊⅊

    1.0

    SHALLOWSTORM

    1.8

    NOTES1. ALL DIMENSIONS IN METRES.2. THE MINIMUM DEPTH OF COVER FOR SANITARY, STORM AND WATER MAINS INDICATED ABOVE CONSIDER FROST

    PROTECTION REQUIREMENTS ONLY.

    3. THE DESIGNED DEPTH OF COVER FOR SANITARY, STORM AND WATER MAINS SHALL BE ENGINEERED WITHCONSIDERATION TO:

    i. ADEQUATE DEPTH OF COVER FOR LOT SERVICES AT PROPERTY LINE.ii. OVERALL DEPTH OF COVER REQUIREMENTS FOR THE ENTIRE DEVELOPMENT AREA.iii. PIPE CROSSING CONFLICTS.

    4. DIRECTIONAL DRILLING OF SHALLOW UTILITIES SHALL ADHERE TO THE DEPTH RANGE SPECIFIED FOR A ROADCROSSING DUCT.

    9. SHALLOW STORM PIPES SHALL HAVE 1.8m MIN DEPTH OF COVER AND 2.9m MAX DEPTH OF COVER.

    BETWEEN MAINS

    PIPE CROWN

    PIPE OBVERT (OBV)

    PIPE INVERT (INV)

    WHERE:

    PIPE INNERDIAMETER (I.D.)

    PIPE OUTERDIAMETER (O.D.)

    WHERE:

    LOG LOG

  • 0.51.5 2.5

    4.5 9.0

    2.5 1.5 2.5

    6.5

    20.0

    130mm PARABOLIC CROWN

    WATER

    MAIN

    PRIMARY

    POWER

    CABLE TV

    TELEPHONE

    GAS

    SANITARY

    SEWER

    SHALLOW

    STORM

    POWER

    CABLE TV

    TELEPHONE

    1.0

    2.0

    1.25

    3.0

    R.O.W.

    P

    L L

    P

    F.O

    .C

    .

    F.O

    .C

    .

    LIGHT

    STANDARD

    HYDRANT

    2.03.25

    5.0

    1.0

    GAS

    STORM

    SEWER

    2.0

    1.5

    2-4m UTILITY

    R.O.W.

    SEPARATE WALK (2% CROSSFALL)

    NOTES:

    50mm TYPE ACR ASPHALT SURFACE COURSE

    75mm TYPE ACB ASPHALT BASE COURSE

    250mm GRANULAR BASE COURSE

    150mm MINIMUM PREPARED SUBGRADE

    MINIMUM ROAD STRUCTURE

    TYPICAL SECTION

    SHALLOW

    STORM

    100mm WICK DRAIN, TIED TO CATCH BASIN

    CURB & GUTTER

    BACKFILL

    300 mm

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    31/03/2014

    25/02/2015

    CURB & GUTTER

    BO

    ULE

    VA

    RD

    3%

    SLO

    PE

    2-4m UTILITY

    SEPERATE WALK

    (2% CROSSFALL)

    BO

    ULE

    VA

    RD

    3%

    SLO

    PE

    1. ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.

    2. ALL ROAD STRUCTURES ARE SUBJECT TO THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT

    AND THE FIELD CONDITIONS AT THE TIME OF CONSTRUCTION.

    3. TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF THE SIGHT LINES AT

    INTERSECTIONS, AND AS CLOSE TO PROPERTY LINES AS IS PRACTICABLE.

  • DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    23/04/2014

    25/02/2015

    NOTES:

    1. ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.

    2. ALL ROAD STRUCTURES ARE SUBJECT TO THE RECOMMENDATIONS IN THE GEOTCHNICAL REPORT AND THE FIELD

    CONDITIONS AT THE TIME OF CONSTRUCTIONS.

    3. TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS, AND AS CLOSE TO

    PROPERTY LINES AS IS PRACTICABLE.

    4. MOUNTABLE CURB AND GUTTER TO BE USED IN RESIDENTIAL DEVELOPMENTS WHERE DRIVEWAYS ARE PRESENT.

    5. STRAIGHT FACE CURB AND GUTTER TO BE USED FOR COMMERCIAL DEVELOPMENTS.

    0.5

    1.5 2.5

    4.511.0

    2.51.5

    2.5

    6.5

    22.0

    150mm PARABOLIC CROWN

    WATER

    MAIN

    PRIMARY

    POWER

    CABLE TV

    TELEPHONE

    GAS

    SANITARY

    SEWER

    SHALLOW

    STORM

    POWER

    CABLE TV

    TELEPHONE

    1.0

    2.0

    1.25

    3.0

    P

    L L

    P

    F.O

    .C

    .

    F.O

    .C

    .

    LIGHT

    STANDARD

    HYDRANT

    2.03.25

    5.0

    1.0

    GAS

    STORM

    SEWER

    2.0

    1.5

    SEPARATE WALK (2% CROSSFALL)

    TYPICAL SECTION

    SHALLOW

    STORM

    50mm TYPE ACO ASPHALT SURFACE COURSE

    125mm TYPE ACB ASPHALT BASE COURSE

    300mm GRANULAR BASE COURSE

    150mm MINIMUM PREPARED SUBGRADE

    MINIMUM ROAD STRUCTURE

    100mm WICK DRAIN, TIED TO CATCH BASIN

    CURB & GUTTER

    BACKFILL

    300mm

    R.O.W.

    2-4m UTILITY

    R.O.W.

    2-4m UTILITY

    CURB & GUTTER

    BO

    ULE

    VA

    RD

    3%

    SLO

    PE

    SEPERATE WALK

    (2% CROSSFALL)

    BO

    ULE

    VA

    RD

    3%

    SLO

    PE

  • 0.5 1.5 2.5

    4.5 12.0

    2.5 1.5 2.5

    6.5

    23.0

    170mm PARABOLIC CROWN

    WATER

    MAIN

    PRIMARY

    POWER

    CABLE TV

    TELEPHONE

    GAS

    SHALLOW

    STORM

    SANITARY

    SEWER

    POWER

    CABLE TV

    TELEPHONE

    1.0

    2.0

    1.25

    3.0

    F.O

    .C

    .

    F.O

    .C

    .

    LIGHT

    STANDARD

    HYDRANT

    2.0

    3.25

    5.0

    1.0

    GAS

    STORM

    SEWER

    2.0

    1.5

    TYPICAL SECTION

    50mm TYPE ACO ASPHALT SURFACE COURSE

    125mm TYPE ACB ASPHALT BASE COURSE

    300mm GRANULAR BASE COURSE

    150mm MINIMUM PREPARED SUBGRADE

    MINIMUM ROAD STRUCTURE

    SHALLOW

    STORM

    100mm WICK DRAIN, TIED TO CATCH BASIN

    CURB & GUTTER

    BACKFILL

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    23/04/2014

    25/02/2015

    300mm

    BO

    ULE

    VA

    RD

    3%

    SLO

    PE

    R.O.W.

    2-4m UTILITY

    R.O.W.

    2-4m UTILITY

    BO

    ULE

    VA

    RD

    3%

    SLO

    PE

    SEPARATE WALK (2% CROSSFALL)

    CURB & GUTTER

    SEPERATE WALK

    (2% CROSSFALL)

    NOTES:

    1. ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.

    2. ALL ROAD STRUCTURES ARE SUBJECT TO THE RECOMMENDATIONS IN THE GEOTCHNICAL REPORT AND THE FIELD

    CONDITIONS AT THE TIME OF CONSTRUCTIONS.

    3. TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS, AND AS CLOSE TO

    PROPERTY LINES AS IS PRACTICABLE.

    4. MOUNTABLE CURB AND GUTTER TO BE USED IN RESIDENTIAL DEVELOPMENTS WHERE DRIVEWAYS ARE PRESENT.

    5. STRAIGHT FACE CURB AND GUTTER TO BE USED FOR COMMERCIAL DEVELOPMENTS.

  • 180mm PARABOLIC CROWN

    15.0 2.0

    37.0

    2.01.0 1.56.5

    POWER CABLE

    7.25

    4

    :

    1

    3

    :

    1

    0.50.5

    1.5

    1.0

    7.25

    6.51.5

    1.5

    POWER CABLE

    4

    :

    1

    3

    :

    1

    SEPARATE WALK (2% CROSSFALL)

    0.5 0.5

    ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.2.

    TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS,1.

    NOTES:

    AND AS CLOSE TO PROPERTY LINES AS IS PRACTICABLE.

    TYPICAL SECTION

    300mm GRANULAR BASE COURSE

    50mm TYPE ACO ASPHALT SURFACE COURSE

    150mm TYPE ACB ASPHALT BASE COURSE

    BACKFILL

    MINIMUM ROAD STRUCTURE

    SCALE 1:10

    HYDRANT IF REQUIRED

    HYDRANT IF REQUIRED

    BERM REQUIRED WHEN RESIDENTIAL BACKS ONTO ARTERIAL

    CURB & GUTTER

    150mm MINIMUM PREPARED SUBGRADE

    100mm WICK DRAIN, TIED TO CATCH BASIN

    CURB & GUTTER

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    300mm

    BOULEVARD

    3% SLOPE

    SEPERATE WALK

    (2% CROSSFALL)

    5.0m

    EASEMENT

    5.0m

    EASEMENT

  • 8.0

    2.0

    45.0

    2.01.0

    1.5

    7.75

    POWER CABLE

    8.5

    4

    :

    1

    3

    :

    1

    1.00.5

    1.5

    1.0

    8.5

    7.75

    1.5

    0.501.0

    1.5

    PL L

    P

    SEPARATE WALK

    POWER CABLE

    4

    :

    1

    3

    :

    1

    4.58.0

    SEPARATE WALK

    2.5%

    2.5%

    7.75

    2% CROSSFALL2% CROSSFALL

    TOWARDS ROAD

    TOWARDS ROAD

    C

    L

    ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.3.

    TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS,1.

    NOTES:

    AND AS CLOSE TO PROPERTY LINES AS IS PRACTICABLE.

    TYPICAL SECTION

    HYDRANT

    BERM REQUIRED WHEN RESIDENTIAL BACKS ONTO ARTERIAL

    MINIMUM ROAD STRUCTURE

    CURB & GUTTER

    CURB

    & GUTTER

    300mm GRANULAR BASE GRANULAR

    50mm TYPE ACO ASPHALT SURFACE COURSE

    ALL UNDERGROUND UTILITY ALIGNMENT TO BE APPROVED UNDER SEPARATE APPLICATION.2.

    150mm TYPE ACB ASPHALT BASE COURSE

    150mm MINIMUM PREPARED SUBGRADE

    100mm WICK DRAIN, TIED TO CATCH BASIN

    BACKFILL

    CURB & GUTTER

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    300mm

    5.0m

    EASEMENT

    BOULEVARD

    3% SLOPE

    BOULEVARD

    3% SLOPE

    5.0m

    EASEMENT

  • DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • PR

    OP

    ER

    TY L

    INE

    FAC

    E O

    F C

    UR

    B

    PARARAMP LOCATED AT APPROXIMATEMID-POINT OF RETURN RADIUS (NOT TOCONFLICT WITH DRIVEWAY LOCATION)

    MOUNTABLE CURB & GUTTER

    20.0

    9.0

    ALL DIMENSIONS IN METRES.NOTES:1.

    6.54.5

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    R15.0(TYP.)

    R12.0

  • ALL DIMENSIONS IN METRES.SIDEWALK TO END AT PROPERTY LINE PRIOR TO CURB RETURN.

    2.

    NOTES:1.

    PR

    OP

    ER

    TY L

    INE

    FAC

    E O

    F C

    UR

    B

    T-BOLLARDS LOCATED AT BACK OFEASEMENT WHEN PUL PRESENT

    WALKWAY OR TRAIL

    PARARAMP LOCATED AT APPROXIMATEMID-POINT OF RETURN RADIUS (NOT TOCONFLICT WITH DRIVEWAY LOCATION)

    MOUNTABLE CURB & GUTTER

    20.0

    9.0

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    MONOLITHIC SIDEWALK

    R15.0(TYP)

    R12.0

  • CURB

    SIDEWALK

    UNIFORM FENCE

    PLPL

    FENCE

    VARIES 6.0m

    CURB

    EA

    SE

    ME

    NT

    0.150 mP TO FENCE

    SIDEWALK

    UNIFORM

    L

    EA

    SE

    ME

    NT

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    VARIES

    1.5mSIDEWALK

    0.150 mP TO FENCEL

    3.0m WALKWAYOR

  • 2.5% MAX

    2% CROSSFALL

    1% MIN 2%

    2%

    2%

    2.5% MAX

    1% MIN

    2%

    PL PL

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    VARIES VARIES0.5m 3.0m WALKWAY

    OR1.5m WALKWAY

    0.5mVARIES VARIES

    VARIES

  • SECTION A-A

    MOUNTABLE CURB

    MIN. 75mm OF COMPACTED GRANULAR FILL

    75

    125

    EXPANSION BOARD

    EXPANSION BOARD

    EXPANSION BOARD

    MIN. 2%

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    24/04/2014

    15/04/2015

    DWELLING

    GARAGE WIDTH

    SIDEWALK

    CITY PROPERTY

    A

    A

    600

    MIN 3000 TO 7500 MAX

    600

    MIN 4200 TO 8700 MAX

    1

    1

    TAPERED PORTION

    ON CITY PROPERTY

    OR 1:1

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.

    2. SIDEWALK CROSSFALL MIN. 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.

    3. NO DOWELING TO CURB OR SIDEWALK.

    4. MAINTAIN MINIMUM CLEARANCE OF 1.25m FROM DRIVEWAY EDGE TO EDGE OF NEAREST STREET FURNITURE.

    5. MAINTAIN MINIMUM CLEARANCE OF 1.5m FROM DRIVEWAY EDGE TO EDGE OF NEAREST TREE.

    6. CALL CITY ENGINEERING SERVICES TO INSPECT APRON FORMS BEFORE CONCRETE POUR.

    7. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

    8. THE WIDTH OF TAPERED APRON ARE NOT TO EXTEND BEYOND THE PROJECTION OF SIDE PROPERTY AT CURB.

    9. DRIVEWAYS CANNOT EXTEND INTO THE CUT CORNER OR CURB RETURN (BC/EC).

    10. APRON MATERIAL MUST BE A POURED IN PLACE CONCRETE.

    11. ASPHALT, PAVING STONES OR OTHER NON-POURED IN PLACE CONCRETE PRODUCTS WILL NOT BE PERMITTED FOR CITY APRONS.

    12. THE CITY RESERVES THE RIGHT TO REPLACE APRONS AND DRIVEWAYS THAT FALL UPON CITY PROPERTY WITH STANDARD CONCRETE IF

    INFRASTRUCTURE REPAIRS ARE REQUIRED.

    MAXIMUM DRIVEWAY

    WIDTH AT BACK OF

    SIDEWALK IS THE

    GARAGE WIDTH

    OR 7.5m

    WHICHEVER IS LESS

    MINIMUM 1.35m

    AT PROPERTY LINE

    IT IS NOT ACCEPTABLE TO

    EXTEND THE WALKWAY

    PORTION OF THE DRIVEWAY

    DIRECTLY TO THE BACK OF

    THE SIDEWALK IF IT EXCEEDS

    THE MAXIMUM DRIVEWAY

    WIDTH.

    PRIVATE PROPERTY

    OPTIONAL

    DRIVEWAY

    EXPANSION

    ON PRIVATE

    PROPERTY

    DRIVEWAY

    APRON

  • SECTION A-A

    MOUNTABLE CURB

    MIN. 75mm OF COMPACTED GRANULAR FILL

    75

    125

    EXPANSION BOARD

    EXPANSION BOARD

    EXPANSION BOARD

    MIN. 2%

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    24/04/2014

    15/04/2015

    DWELLING

    GARAGE WIDTH

    MAXIMUM DRIVEWAY

    WIDTH AT BACK OF

    SIDEWALK IS

    GARAGE WIDTH

    OR 7.5m

    WHICHEVER IS LESS

    SIDEWALK

    APRON

    A

    A

    600

    MIN 3000 TO 7500 MAX

    600

    MIN 4200 TO 8700 MAX

    1

    1

    TAPERED PORTION

    ON CITY PROPERTY

    OR 1:1

    CITY PROPERTY

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.

    2. SIDEWALK CROSSFALL MIN. 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.

    3. NO DOWELING TO CURB OR SIDEWALK.

    4. MAINTAIN MINIMUM CLEARANCE OF 1.25m FROM DRIVEWAY EDGE TO EDGE OF NEAREST STREET FURNITURE.

    5. MAINTAIN MINIMUM CLEARANCE OF 1.5m FROM DRIVEWAY EDGE TO EDGE OF NEAREST TREE.

    6. CALL CITY ENGINEERING SERVICES TO INSPECT APRON FORMS BEFORE CONCRETE POUR.

    7. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

    8. THE WIDTH OF TAPERED APRON ARE NOT TO EXTEND BEYOND THE PROJECTION OF SIDE PROPERTY AT CURB.

    9. DRIVEWAYS CANNOT EXTEND INTO THE CUT CORNER OR CURB RETURN (BC/EC).

    10. APRON MATERIAL MUST BE A POURED IN PLACE CONCRETE.

    11. ASPHALT, PAVING STONES OR OTHER NON-POURED IN PLACE CONCRETE PRODUCTS WILL NOT BE PERMITTED FOR CITY APRONS.

    12. THE CITY RESERVES THE RIGHT TO REPLACE APRONS AND DRIVEWAYS THAT FALL UPON CITY PROPERTY WITH STANDARD CONCRETE IF

    INFRASTRUCTURE REPAIRS ARE REQUIRED.

    MINIMUM 1.35m

    AT PROPERTY LINE

    IT IS NOT ACCEPTABLE TO

    EXTEND THE WALKWAY

    PORTION OF THE DRIVEWAY

    DIRECTLY TO THE BACK OF

    THE SIDEWALK IF IT EXCEEDS

    THE MAXIMUM DRIVEWAY

    WIDTH.

    PRIVATE PROPERTY

    OPTIONAL

    DRIVEWAY

    EXPANSION

    ON PRIVATE

    PROPERTY

    OPTIONAL

    DRIVEWAY

    EXPANSION

    ON PRIVATE

    PROPERTY

    DRIVEWAY

  • SECTION A-A

    MOUNTABLE CURB

    MIN. 75mm COMPACTED GRANULAR FILL

    75

    125

    EXPANSION BOARD

    EXPANSION BOARD

    EXPANSION BOARD

    MIN. 2%

    A

    A

    DWELLING DWELLING

    MIN. GAP 2.5m

    1.25m 1.25m

    600

    Min 3000 to 5500 Max

    600

    600

    600

    Min 4200 to 6700 Max

    Min 3000 to 5500 Max

    Min 4200 to 6700 Max

    DRIVEWAY DRIVEWAY

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    24/04/2014

    15/04/2015

    GARAGE WIDTH GARAGE WIDTH

    MAXIMUM DRIVEWAY

    WIDTH AT BACK OF

    SIDEWALK IS

    GARAGE WIDTH

    OR 5.5m

    WHICHEVER IS LESS

    APRON APRON

    SIDEWALK

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.

    2. SIDEWALK CROSSFALL MIN. 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.

    3. NO DOWELING TO CURB OR SIDEWALK.

    4. MAINTAIN MINIMUM CLEARANCE OF 1.25m FROM DRIVEWAY EDGE TO EDGE OF NEAREST STREET FURNITURE.

    5. MAINTAIN MINIMUM CLEARANCE OF 1.5m FROM DRIVEWAY EDGE TO EDGE OF NEAREST TREE.

    6. CALL CITY ENGINEERING SERVICES TO INSPECT APRON FORMS BEFORE CONCRETE POUR.

    7. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

    8. THE WIDTH OF TAPERED APRON ARE NOT TO EXTEND BEYOND THE PROJECTION OF SIDE PROPERTY AT CURB.

    9. DRIVEWAYS CANNOT EXTEND INTO THE CUT CORNER OR CURB RETURN (BC/EC).

    10. APRON MATERIAL MUST BE A POURED IN PLACE CONCRETE.

    11. ASPHALT, PAVING STONES OR OTHER NON-POURED IN PLACE CONCRETE PRODUCTS WILL NOT BE PERMITTED FOR CITY APRONS.

    12. THE CITY RESERVES THE RIGHT TO REPLACE APRONS AND DRIVEWAYS THAT FALL UPON CITY PROPERTY WITH STANDARD CONCRETE IF

    INFRASTRUCTURE REPAIRS ARE REQUIRED.

    MIN. GAP 2.5m

    HYDRANT

    M

    I

    N

    .

    1

    .

    2

    5

    m

    M

    I

    N

    .1

    .

    2

    5

    m

    MAXIMUM DRIVEWAY

    WIDTH AT BACK OF

    SIDEWALK IS

    GARAGE WIDTH

    OR 5.5m

    WHICHEVER IS LESS

    LOT WIDTH LESS THAN 12.2mLOT WIDTH LESS THAN 12.2m

  • PLAN

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    13/08/2013

    13/05/2015

    A

    A

    SECTION A-A

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%

    2. TYPICAL BOULEVARD CROSSFALL IS 3% FROM TOC ELEVATION UP TO THE PROPERTY LINE ELEVATION UNLESS OTHERWISE NOTED.

    3. COMMERCIAL CROSSING SHALL BE MIN. 180mm IN THICKNESS REINFORCED WITH 100 X 200 No. 6 STEEL WELDED WIRE MESH OR MIN.

    10M REBAR SPACED @ 300mm O.C. IN BOTH DIRECTIONS.

    4. EXISTING ROADWAY CURB AND GUTTER TO BE REMOVED & REPLACED WITH TAPER DROP CURB SECTIONS.

    5. MAINTAIN MIN 1.5m CLEARANCE TO NEAREST STREET FURNITURE, FIRE HYDRANT, AND TREES.

    6. COMMERCIAL CROSSING TO BE COMPLETED IN 2 POURS. FORM AND POUR THE CURB & GUTTER. INSTALL DOWELS AT THE

    CONNECTIONS TO EXISTING CONCRETE CURBS. INSTALL EXPANSION BOARD BETWEEN THE CURB & GUTTER AND THE CONCRETE

    APRON. POUR THE CONCRETE APRON. INSTALL EXPANSION BOARD AT THE CONNECTION TO THE EXISTING SIDEWALK (IF PRESENT).

    7. COMMERCIAL CROSSING TO BE CONSTRUCTED USING CONCRETE FROM CURB LINE TO PROPERTY LINE AND ACCOMMODATE ANY

    EXISTING SIDEWALK (IF PRESENT) WITH EXPANSION BOARDS.

    8. MINIMUM 3.0m x 3.0m SQUARE JOINTS SAWCUT INTO CONCRETE.

  • P

    L

    PLAN

    A

    A

    SAWCUT

    EXISTING

    CURB

    PROVIDE

    3 x 10M

    REBAR

    DOWELS

    SAWCUT

    EXISTING

    CURB

    PROVIDE

    3 x 10M

    REBAR

    DOWELS

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    150mm

    150mm

    9.0m MIN

    CO

    NC

    RE

    TE

    AP

    RO

    N

    CURB TO MATCH EXISTING

    P

    L

    1.5m SIDEWALK

    150mm COMPACTED GRANULAR FILL

    D

    R

    A

    IN

    A

    G

    E

    P

    L

    SECTION A-A

    DRAINAGE

    WIDTH TO

    MATCH AND MIRROR

    EXISTING GUTTER

    PAN

    200

    TYP.

    25

    TYP.

    EXPANSION BOARD

    6

    0

    1

    8

    0

    1

    5

    0

    CONCRETE OR

    ASPHALT PAVEMENT

    FOC = FACE OF CURB

    BOC = BACK OF CURB

    TOC = TOP OF CURB

    LOG = LIP OF GUTTER

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.

    2. TYPICAL BOULEVARD CROSSFALL IS 3% FROM TOC ELEVATION UP TO THE PROPERTY LINE ELEVATION UNLESS OTHERWISE NOTED.

    3. COMMERCIAL CROSSING SHALL BE MIN. 180mm IN THICKNESS REINFORCED WITH 100 X 200 No. 6 STEEL WELDED WIRE MESH OR MIN.

    10M REBAR SPACED @ 300mm O.C. IN BOTH DIRECTIONS.

    4. EXISTING ROADWAY CURB & GUTTER TO BE REMOVED & REPLACED WITH MIRRORED CONCRETE GUTTER.

    5. EXISTING ROADWAY CURB & GUTTER TO CONNECT TO CONCRETE APRON AS SHOWN.

    6. MAINTAIN MIN 1.5m CLEARANCE TO NEAREST STREET FURNITURE, FIRE HYDRANT, AND TREES.

    7. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.

    8. COMMERCIAL CROSSING TO BE COMPLETED IN 2 POURS. FORM AND POUR THE CURB AND GUTTER. INSTALL DOWELS AT THE

    CONNECTIONS TO EXISTING CONCRETE CURBS. INSTALL EXPANSION BOARDS. POUR THE CONCRETE APRON.

    9. COMMERCIAL CROSSING TO BE CONSTRUCTED USING CONCRETE FROM ROADWAY TO PROPERTY LINE.

    10. IF PRESENT, EXISTING SIDEWALK BETWEEN THE PEDESTRIAN RAMPS INSIDE THE CONCRETE APRON TO BE SAW CUT AND REMOVED.

    11. MINIMUM 3.0m x 3.0m SQUARE JOINTS SAWCUT INTO CONCRETE.

    5

    .

    0

    m

    R

    5

    .

    0

    m

    R

    BOC

    FOC

    SAWCUT AND REMOVE EXISTING SIDEWALK

    1

    5

    0

    150mm PREPARED SUBGRADE - 100% SPD

    13/08/2013

    STRAIGHT FACE CURB AND GUTTER

    LOG

    EXPANSION BOARD

    13/05/2015

    SQUARE OFF TRANSITION

    MIN. 500mm WIDTH

  • 30003000

    7300

    6.0m LANE

    CL

    1500

    VARIES

    LP

    75 SAG (ROLLED F.C.)100 SAG (VERT F.C.)

    DETAIL A

    450

    140 OR 200

    40R=150

    R=150

    PL

    DETAIL A

    25

    DROP CURB

    50

    150 x 150 STEEL MESH REINFORCING

    50mm COMPACTED GRANULAR FILL

    1:40SECTION A-A

    50

    NOTES:1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%2. SIDEWALK CROSSFALL TO 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.3. LANE APRONS SHALL BE MINIMUM 150mm THICK WITH 150 x 150 NO. 6 STEEL MESH REINFORCEMENT CAN SUBSTITUTE

    #10M OR BETTER REBAR @ 12" OC BOTH DIRECTIONS.4. EXISTING STANDARD CURB & GUTTER TO BE REMOVED AND REPLACED WITH TAPER AND DROP CURB SECTIONS.5. MAINTAIN MIN 1.5m CLEARANCE TO NEAREST STREET FURNITURE, FIRE HYDRANT, AND TREES.6. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED.

    150

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    EXPANSION BOARD

  • DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. ALL DIMENSIONS IN MILLIMETERS.2. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%3. CONCRETE REINFORCED WITH #10M OR BETTER REBAR PLACED AT 100mm DEEP AND 300mm EACH WAY.4. 50 mm DEEP TRANSVERSE SAWCUTS TO BE MADE AT 3.0mm C-C AND CAULKED WITH AN APPROVED SEALANT ALONG

    LIP OF GUTTER. (OR CONTRACTION JOINT DURING INSTALLATION.)

    EXPANSION BOARD

    2% 100

    150

    1253%

    EXPANSION BOARD

    250 150150 STANDARD REVERSE CURB & GUTTER

    1500SIDEWALK3500

    ROADWAY

    200mm PREPARED SUBGRADE

    200mm CONCRETE 30MPa

    BUS BAY

    A

    SIDEWALK

    A

    PLAN

    SECTION A-A

    MATCH AND MIRROR EXISTING GUTTER

    GUTTERCURB

  • 10M BAR

    2.2m

    125

    2.0% X-FALL

    STANDARD MONOWALK

    SECTION A-ASCALE: NTS

    EXPANSION BOARD

    5050mm COMPACTEDGRANULAR FILL TO

    98% S.P.D.

    CURB & GUTTER

    2.2m

    3.5m

    A

    A

    BUS PAD(USE FOR BUS SHELTER

    IF REQUIRED)

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR

    ENTRAINMENT 5% TO 7%2. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.

  • 125

    2.0% X-FALL

    1.5m

    SECTION A-A

    SCALE: NTS

    2.5m

    STOP AND SHELTER PAD

    SIDEWALK

    50

    75

    GRANULAR SUBGRADE

    COMPACTED TO 98% S.P.D.

    10M REBAR

    EXPANSION BOARDS

    CURB

    A

    A

    2.5m

    5.0m

    BUS STOP PAD

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.

    2. CONTRACTION JOINTS ARE TO BE PROVIDED AT A MINIMUM 3.0m SPACING.

    3. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.

    4. THE DEVELOPER IS RESPONSIBLE TO INSTALL BUS SHELTERS UPON ARTERIAL ROADS.

    5. THE DEVELOPER IS RESPONSIBLE TO INSTALL BUS SHELTERS UPON COLLECTOR ROADS ADJACENT TO MULTI-FAMILY SITES.

    6. CITY OF ST. ALBERT BRANDING STAMP TO BE PLACED IN THE CORNER AT THE BUS STOP PAD (AS SHOWN). THE EDGE OF THE

    STAMP IS TO BE LOCATED 80mm FROM THE EDGE AT THE BUS STOP PAD AND 80mm FROM THE BOC. APPLY A RELEASING

    AGENT TO THE SURFACE OF THE CONCRETE WHEN APPLYING THE BRANDING STAMP.

    7. BUS STOP BENCH MUST BE ANCHORED TO THE CONCRETE PAD.

    8. THE FRONT EDGE OF BUS STOP BENCH MUST BE SET BACK A MINIMUM 1.5m FROM THE FACE OF CURB AND ANGLED TO FACE

    DIRECTION OF TRAVEL. THE REAR EDGE OF THE BUS STOP BENCH MUST NOT EXTEND ONTO THE SIDEWALK.

    9. THE FRONT EDGE OF THE BUS STOP SHELTER MUST BE SET BACK A MINIMUM OF 1.0m FROM THE FACE OF CURB. THE REAR

    EDGE OF THE BUS STOP SHELTER (INCLUDING ANCHOR PLATE) MUST NOT EXTEND ONTO THE SIDEWALK.

    10. THE OPENING OF THE BUS STOP SHELTER MUST DIRECT USERS TO THE SIDEWALK.

    11. ADVERTISEMENTS UPON BUS STOP BENCHES AND SHELTERS ARE NOT PERMITTED WITHOUT WRITTEN CONSENT FROM THE

    CITY OF ST. ALBERT TRANSIT DEPARTMENT.

    01/10/2013

    VEHICLE DIRECTION OF TRAVEL

    FOC

    BOC

    0.5m - 2.5m

    80

    B

    E

    N

    C

    H

    9.0m

    BUS SHELTER PAD

    4.0m

    80

    BUS STOP

    SIGN POST

    50-150

    750

    12/03/2015

    SHELTER

    3.0% X-FALL

  • 125

    2.0% X-FALL

    1.5m

    SECTION A-ASCALE: NTS

    2.5mBUS PAD

    SIDEWALK

    5050mm

    COMPACTED GRANULARFILL AT 98% S.P.D. 10M BAR

    (TYP.)

    EXPANSION BOARDS

    CURB & GUTTER

    A

    A

    2.5m 5.0m

    BUS STOP PAD

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%2. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.3. CITY OF ST. ALBERT BRANDING STAMP TO BE PLACED IN THE CORNER AT THE BUS STOP PAD (AS SHOWN). THE EDGE OF THE STAMP IS

    TO BE LOCATED 80mm FROM THE EDGE AT THE BUS STOP PAD AND 80mm FROM THE BOC. APPLY A RELEASING AGENT TO THESURFACE OF THE CONCRETE WHEN APPLYING THE BRANDING STAMP.

    01/10/2013

    VEHICLE DIRECTION OF TRAVEL

    FOC

    BOC

    80mm80mm

    BENC

    H

  • 1 3/4" (44.45mm)

    900m

    m

    WASHER NYLOC STYLE

    LOCKING NUT

    SIGN BOARD

    NOTE:

    ALL FASTENING HARDWARE

    MUST HAVE NON-CORROSIVE

    COATING

    SIGN BOARD FASTENING DETAIL

    SIDEWALK OR PATH

    1.0m

    min 2.0m

    1.0m

    SIDEWALK

    X

    ACTUAL INCH & MILLIMETER SIZES

    1.75"

    2.00"

    2.25"

    2.50"

    WALL

    0.105"

    44.45mm

    50.80mm

    57.15mm

    63.50mm

    2.667mm

    1.875" 47.50mm

    3/8" GALVANIZED STEEL

    CONCRETE

    2" OM, 1 3/4" IM GALVANIZED STEEL

    APPROVED POSTS AND HARDWARE:

    GROUND & CONCRETE MOUNT:

    - TELESPAR.

    - SQUARE FIT.

    - EACH SIGN INSTALLATION REQUIRES

    A POST, BASE, AND BASE SLEEVE.

    1/2 X or 1.0m FROM FACE OF

    CURB, WHICH EVER IS LESS

    CONCRETE

    POST INSTALLATION DETAIL

    GROUND

    POST INSTALLATION DETAIL

    EXISTING GROUND

    1 3/4" GALVANIZED STEEL

    TELESPAR POST

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    max 3.0m

    min 2.0m

    max 3.0m

    min 2.0m

    max 3.0m

    10" (254mm)

    TELESPAR. WITH 7/16" HOLES EVERY

    INCH ON THE FULL LENGTH ON ALL

    4 SIDES OF THE SQUARE POST

    SQUARE BASE PLATE

    8" (203.2mm)

    7" (177.8mm)

    3/8" (9.53mm)

    5/8" (15.88mm)

    NOTES:

    1) WHERE AVAILABLE, MOUNT SIGNS TO EXISTING STREET POLES.

    2) OTHER THAN PARKING/STOPPING RESTRICTION SIGNS, MOUNT SIGNS

    PERPENDICULAR TO THE ROADWAY.

    3) DO NOT INSTALL POSTS WITH BREAKAWAY DEVICES UNLESS DIRECTED

    BY THE CITY.

    4) STEEL BANDING IS TO BE USED TO SUPPORT THE BRACKET AND HOLD

    THE SIGN THAT IS TO BE MOUNTED.

    5) USE "U'" SHAPED BRACKETS (PART UB021).

  • 150mm x 150mm DARK COLORED RECYCLED PLASTIC BOLLARD

    1.0

    CONCRETEBACKFILLED WITH

    AUGER HOLE 1.0

    75 m

    m 75m

    m

    GROUND LINE

    BOLLARDS LAYOUT FOR END OF THE ROAD STRUCTURE

    SID

    EW

    ALK

    SID

    EW

    ALK

    PR

    OP

    ER

    TY L

    INE

    PR

    OP

    ER

    TY L

    INE

    WA-8

    2400

    WA-8

    75mm WIDE RED REFLECTIVE TAPE

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    15/01/14DD/MM/YY

    2.02.5 2.0 2.0 2.5 2.52.52.5 2.0

    4.5 9.0 6.5

    NOTES:1. ALL UNITS IN METRES UNLESS NOTED OTHERWISE.2. BOLLARD SPACING MEASURED ON CENTRE OF BOLLARDS.3. A BOLLARD AND THE WARNING SIGN ARE TO BE PLACED AT THE CENTER LINE OF THE ROADWAY.4. BOLLARDS ARE TO BE SET PLUMB.5. THE TOP OF BOLLARD ELEVATION SHOULD BE CONSISTENT ALONG A SET OF BOLLARDS.

    CL

    TOP OF BOLLARD ELEVATION

  • NOTES1. ALL UNITS IN METRES UNLESS OTHERWISE NOTED.2. POSITION BOLLARDS MINIMUM 1.0m BEHIND UTILITY EASEMENT.3. CAN BE USED WITH 1.5m WALK OR NO SIDEWALK4. MAXIMUM WIDTH OF PUBLIC WORKS MAINTENANCE EQUIPMENT IS 73".5. BOLLARDS ARE TO BE SET PLUMB.6. THE TOP OF BOLLARD ELEVATION SHOULD MATCH ONE ANOTHER.

    1.751.75

    2.252.25

    6.0m P.U.L.

    PR

    OP

    ER

    TY L

    INE

    PR

    OP

    ER

    TY L

    INE

    1.0

    2-4m (TYP.)UTILITY

    EASEMENT

    PLAN

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    08/04/2014

    1.0

    CONCRETEBACKFILLED WITH

    AUGER HOLE 1.0

    75m

    m 75m

    m

    GROUND LINE

    75mm WIDEWHITE REFLECTIVETAPE

    150mm x 150mm DARK COLOREDRECYCLED PLASTIC BOLLARD

    DETAIL

    SIDEWALK

    1.5mCONCRETE WALK

    TOP OF BOLLARD ELEVATION

    2.5

    GAP2.35

    (92.5")

  • STYLE OF LINE DIMENSION (m) NAME/USE/COLOR

    SOLID

    BROKEN

    DENSEBROKEN

    WIDESOLID

    WIDEBROKEN

    DOUBLESOLID

    SIMULTANEOUSSOLID AND

    BROKEN

    DOUBLEBROKEN

    10cm

    10cm 6m

    3m

    10cm 0.5m

    0.05m

    20cm

    20cm 3.0m

    3.0m

    10cm

    10cm

    10cm

    10cm 3m 6m 3m

    10cm10cm

    10cm 3m 6m 3m

    -EDGE LINES (WHITE OR YELLOW)-DIRECTIONAL DIVIDING LINES (YELLOW)-LANE LINES PROHIBITING LANE CHANGES (WHITE)

    -LANE LINES (WHITE)

    -GUIDE LINES (eg. INTERSECTION MOVEMENTS) YELLOW OR WHITE.

    -EDGE LINES IN CRITICAL AREAS (WHITE ON THE RIGHT, YELLOW ON THE LEFT)-CONTINUITY LINES PROHIBITING LANE CHANGES (WHITE)

    -CONTINUITY LINES IN MERGING AND DIVERGING AREAS-FORCED TURN LANE (LANE ENDING)

    -DIRECTIONAL DIVIDING LINES (YELLOW)-LANE LINES WHERE LANE CHANGES FROM EITHER SIDE ARE PROHIBITED (WHITE)

    -DIRECTIONAL DIVIDING LINES, TWO-WAY LEFT TURN LANES (YELLOW)-LANE LINES WHERE LANE CHANGES FROM ONE SIDE ARE PROHIBITED (WHITE)

    -REVERSIBLE LANES (YELLOW)

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    10cm

  • SIDEWALK

    FACE OF CURB

    SIDEWALK

    FACE OF CURB

    MIN 0.65m FROM FOC

    10cm WHITE CROSSWALKLINE10cm YELLOW CENTERLINE

    MIN 1.0m

    30cm WHITESTOP BAR LINE

    NOTES:

    1. INLAID TRANSVERSE MARKINGS ARE TO BE MINIMUM 8mm DEEP2. YELLOW CENTER LINE IS TO BE CARRIED TO THE BACK CROSSWALK LINE3. THE STOP BAR IS TO BE PLACED PERPENDICULAR TO THE ROADWAY -

    MINIMUM DISTANCE TO THE CROSSWALK IS 1.0m

    MIN.3.0m

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 30cm

    60cmLIP OF GUTTER

    CURBFACE

    CENTRE OF ROAD

    3m

    1.80m 1.85m 1.85m 1.85m 1.85m 1.80m

    5.50m 5.50m

    11.0m

    LIP OF GUTTER

    CURBFACE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 60cm

    30 cm

    70cm

    EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL

    CENTRE OF ROAD

    SECONDARY LINE SECONDARY LINE

    LIP OFGUTTER

    CURBFACE

    70cm

    RIGHT TURN CUT-OFF

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    1.0 2.0

    3.0

    6.0

    1.02.0

    3.0

    6.0

    NOTES:1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE NOTED.2. ENTERING LANE LINES ARE 1.0m OFF OF ZEBRA BARS.3. ENTERING YELLOW CENTER LINE IS 1.0m OFF OF ZEBRA BARS.4. EXITING LANE LINES ARE 2.0m OFF OF ZEBRA BARS.5. EXITING YELLOW CENTER LINE IS 1.0m OFF OF ZEBRA BARS.

  • MIN 6m

    30cm STOP LINE

    NOTES:1. LENGTH OF STOP BOX TO BE DETERMINED BY TURNING TEMPLATES2. IF LANE LINES ARE 10cm WIDE, THEN THE LINE (RIGHT SIDE) OF THE PENALTY BOX SHALL BE

    10cm FROM BACK STOP BAR TO CROSSWALK.3. IF IT IS A TURN LANE, THE LANE LINES SHALL BE 20cm WIDE AND THE LINE (RIGHT SIDE) OF

    THE PENALTY BOX SHALL BE 20cm FROM BACK STOP BAR TO CROSSWALK.4. A 3.0m LANE LINE (20cm OR 10cm) SHALL RUN DIRECTLY OFF OF THE BACK STOP BAR.

    THEREFORE, TOTAL DISTANCE OF SOLID LINE FROM CROSSWALK TO FIRST GAP OF LANELINES PRIOR TO THE PENALTY BOX IS A MINIMUM OF 9.0m.

    30cm STOP LINE

    YC

    LY

    CL

    10cm CROSSWALK (MIN. 3.0m WIDE)10

    cm O

    R 2

    0cm

    LA

    NE

    LIN

    E

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    10cm CONTINUITY LINE OR 20cm CONTINUITY LINE

    10cm PENALTY BOX

  • 5.5m min

    3.0m

    1.0m min

    GORE STOPS AT CROSSWALK

    3.0m

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. LANE LINES STOP AT STOP BARS.2. CROSSWALK LINES RUN TO THE CURB.

  • MINORCOLLECTOR

    30m MIN

    MAJORCOLLECTOR

    ARTERIAL

    ARTERIAL

    30m MIN

    LANE LINE - LEAD-INON MAJOR COLLECTOR

    DIRECTIONAL DIVIDING LINELEAD-IN ON MINOR COLLECTOR

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • YY

    Y

    4

    1

    1

    1

    11

    2

    3

    3

    3

    3

    3

    3

    Y

    16.0

    4.65

    6.0

    FULL

    Y S

    IGN

    ALI

    ZED

    INTE

    RS

    EC

    TIO

    N

    MID

    -BLO

    CK

    PE

    DE

    STR

    IAN

    CR

    OS

    SIN

    G

    PE

    DE

    STR

    IAN

    AC

    TIV

    ATE

    D S

    IGN

    ALI

    ZED

    INTE

    RS

    EC

    TIO

    N

    3

    2

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    1.0

    2.0

    3.0

    6.0

    1.0

    2.0

    3.06.0

    NO

    TES

    :1.

    ALL

    DIM

    EN

    SIO

    NS

    AR

    E IN

    ME

    TRE

    S U

    NLE

    SS

    OTH

    ER

    WIS

    E N

    OTE

    D.

    2.E

    NTE

    RIN

    G L

    AN

    E L

    INE

    S A

    RE

    1.0

    m O

    FF O

    F ZE

    BR

    A B

    AR

    S.

    3.E

    NTE

    RIN

    G Y

    ELL

    OW

    CE

    NTE

    R L

    INE

    IS 1

    .0m

    OFF

    OF

    ZEB

    RA

    BA

    RS

    .4.

    EX

    ITIN

    G L

    AN

    E L

    INE

    S A

    RE

    2.0

    m O

    FF O

    F ZE

    BR

    A B

    AR

    S.

    5.E

    XIT

    ING

    YE

    LLO

    W C

    EN

    TER

    LIN

    E IS

    1.0

    m O

    FF O

    F ZE

    BR

    A B

    AR

    S.

  • SIGNAL POLE

    MIN. 3.0m

    16.0m

    4.65m MIN

    CROSSWALK

    STOP BAR

    STOP BAR

    16.0m

    16.0m

    STOP BAR

    STOP BAR

    STOP BAR

    STOP BAR

    4.65m MIN

    16.0m

    NOTES:1. LANE LINES RUN UP UNTIL THE STOP BAR

    AND EXIT OUT OF THE CROSSWALK.2. CENTER LINE RUNS UP TO THE FRONT

    CROSSWALK.

    SCENARIO 1:

    SCENARIO 2:

    SCENARIO 3:

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • SIGNAL POLE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 10cm YELLOW GUIDE LINELINE/GAP RATIO 0.5:0.5 20cm WHITE CONTINUITY LINE

    LINE/GAP RATIO 3:3

    10cm WHITE GUIDE LINELINE/GAP RATIO 0.5:0.5

    20cm WHITE CONTINUITY LINELINE/GAP RATIO 3:3

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 5.5m

    5.5m

    5.5m

    20cm WHITECONTINUITY LINE 3:3 CONTINUITY LINE

    NOT REQUIRED

    20cm WHITECONTINUITY LINE3:3

    20cm WHITECONTINUITY LINE 3:3

    20cm WHITECONTINUITY LINE

    3:3

    CONTINUITY LINENOT REQUIRED

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    10cm WHITE GORE LINE

  • 10cm WHITE LANE LINE 3:6 60m

    30m

    10cm WHITE LANE LINE 3:6

    80m 30m

    10cm WHITE LANE LINE 3:6

    20cm WHITE BROKEN LINE 3:3

    80m 30m

    SPEED LIMITS OF 60 km/h OR LESS

    SPEED LIMITS OF 70 km/h TO 90 km/h

    SPEED LIMITS OF 100 km/h OR GREATER

    120m

    260m

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    CENTERLINE OF ROAD

    CENTERLINE OF ROAD

    CENTERLINE OF ROAD

    20cm WHITE BROKEN LINE 3:3

    20cm WHITE BROKEN LINE 3:3

    CURB FACE

    CURB FACE

    CURB FACE

  • 10cm WHITE LANE LINE 3:6

    20cm WHITE BROKEN LINE 3:3

    60m

    30m

    20 cm WHITE BROKEN LINE 3:3

    80 m 30 m

    10 cm WHITE LANE LINE 3:6

    20 cm WHITE BROKEN LINE 3:3

    80 m 30 m

    SPEED LIMITS OF 60 km/h OR LESS

    SPEED LIMITS OF 70 km/h TO 90 km/h

    SPEED LIMITS OF 100 km/h OR GREATER

    120 m

    260 m

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    CENTERLINE OF ROAD

    CURB FACE

    10cm WHITE LANE LINE 3:6

    CENTERLINE OF ROAD

    CURB FACE

    CENTERLINE OF ROAD

    CURB FACE

  • 20cm

    WH

    ITE

    BR

    OK

    EN

    LIN

    E 3

    :3

    30m

    80m

    120m

    AD

    DIT

    ION

    AL

    AR

    RO

    WS

    SH

    OU

    LD B

    EA

    DD

    ED

    AT

    120

    m IN

    TER

    VA

    LS T

    O A

    MA

    XIM

    UM

    OF

    4 A

    RR

    OW

    S IN

    TO

    TAL

    40m

    20 c

    m W

    HIT

    E B

    RO

    KE

    N L

    INE

    3:3

    LAN

    E C

    HA

    NG

    E A

    RR

    OW

    RE

    QU

    IRE

    D F

    OR

    FO

    LLO

    WIN

    G

    -LE

    FT O

    R R

    IGH

    T LA

    NE

    DR

    OP

    -ME

    RG

    E L

    AN

    E G

    RE

    ATE

    R T

    HA

    N 2

    00 m

    -DO

    UB

    LE L

    AN

    E E

    NTR

    Y-U

    NP

    RO

    TEC

    TED

    TU

    RN

    LA

    NE

    -WH

    EN

    A T

    HR

    OU

    GH

    LA

    NE

    BE

    CO

    ME

    S A

    TU

    RN

    LA

    NE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 10cm WHITE EDGE LINE

    10cm WHITE SOLID LINE

    10cm WHITE EDGE LINE

    10cm WHITE SOLID LANE LINESTARTING AT BEGINNING OFCURVE

    CONTINUITY LINE LENGTHAND NUMBER OF ARROWS

    TRAVELTIME(sec)

    ROADWAYSPEED LIMIT

    (km/h)

    CONTINUITYLINE LENGTH

    (m)

    NUMBEROF

    ARROWS

    ARROWSPACING AT

    (m)

    448881212

    5060708090100110

    6060140140140260260

    1122233

    404040, 8040, 8040, 8040, 80, 12040, 80, 120

    FOR SPEEDS ABOVE 100 km/h OR 110 km/h ADDITIONAL ARROWSMAY BE ADDED IF SPACE IS AVAILABLE AT 120m

    20cm WHITE CONTINUITY LINE 3:3

    10cm WHITE BROKEN LINE 3:6

    40m

    80m

    120m

    SEE TABLEFOR

    CONTINUITYLINE LENGTH

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • CONTINUITY LINE LENGTHAND NUMBER OF ARROWS

    TRAVELTIME(sec)

    ROADWAYSPEED LIMIT

    (km/h)

    CONTINUITYLINE LENGTH

    (m)

    NUMBEROF

    ARROWS

    ARROWSPACING AT

    (m)

    448881212

    5060708090100110

    6060140140140260260

    1122233

    404040, 8040, 8040, 8040, 80, 12040, 80, 120

    FOR SPEEDS ABOVE 100 km/h OR 110 km/h ADDITIONAL ARROWSMAY BE ADDED IF SPACE IS AVAILABLE AT 120m

    SEE TABLEFOR

    CONTINUITYLINE LENGTH

    10 m

    10m

    10cm WHITE EDGE LINE

    10cm YELLOW EDGE LINE

    10cm WHITE EDGE LINE

    20cm WHITE EDGE LINE

    20cm WHITE LINE

    10cm DOUBLE WHITE SOLID LANE LINEBEGINNING AT TAIL END OF FIRST SETOF ARROWS

    10cm YELLOWEDGE LINE

    20cm WHITEGORE LINE

    40m

    80m

    120m

    20cm WHITE CONTINUITY LINE 3:3

    10cm WHITE LANE LINE 3:6

    10cm WHITE EDGE LINE10cm WHITE BROKEN LINE 3:6

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 10 cm WHITE EDGE LINE

    4 SECONDS OFTRAVEL TIME

    AT SPEED LIMIT

    10 cm WHITE EDGE LINE

    4 SECONDS OFTRAVEL TIME

    AT SPEED LIMIT 10 m

    10 cm WHITE EDGE LINE

    10 m10 m

    10 m

    END OF TAPER END OF TAPER

    10 cm WHITE SEPARATION 3:6

    10 cm YELLOW EDGE LINE

    20 cm WHITE CONTINUITYLINE LINE/GAP RATIO 3:3

    20 cm WHITE EDGE LINE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    TRANSITION POINT(TYP.)

    10mSPACING

  • 10m

    1.25m

    10cm SOLID EDGE LINE

    DIVERGING GORE DETAIL

    0.50m

    MERGING GORE DETAIL

    10cm SOLID EDGE LINE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 10 m

    10 c

    m W

    HIT

    E E

    DG

    E L

    INE

    EN

    D O

    F TA

    PE

    R

    4 S

    EC

    ON

    D O

    F TR

    AV

    EL

    TIM

    E A

    T S

    PE

    ED

    LIM

    IT

    5.5

    m

    10 m

    20 c

    m W

    HIT

    E E

    DG

    E L

    INE

    10 c

    m W

    HIT

    E E

    DG

    E L

    INE

    10 c

    m W

    HIT

    E E

    DG

    E L

    INE

    ED

    GE

    LIN

    E IF

    RE

    QU

    IRE

    D

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    TRA

    NS

    ITIO

    N P

    OIN

    T

    20 c

    m W

    HIT

    E L

    AN

    E L

    INE

    S 3

    :3

  • 10cm

    SO

    LID

    ED

    GE

    LIN

    E

    1.25m

    10m

    20cm

    CO

    NTI

    NU

    ITY

    LIN

    E 3

    :3

    10cm

    BR

    OK

    EN

    LIN

    E 3

    :6

    10cm

    YE

    LLO

    W C

    L

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 10m10m

    Y

    Y

    CE

    NTR

    E L

    INE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • ED

    GE

    LIN

    E IF

    RQ

    UIR

    ED

    10m

    TO B

    EG

    INN

    ING

    OF

    20 c

    m E

    DG

    E L

    INE

    10m

    GO

    RE

    AR

    EA

    10m

    5.5m

    20cm

    CO

    NTI

    NU

    ITY

    LIN

    E 3

    :3

    10cm

    WH

    ITE

    ED

    GE

    LIN

    E

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • DD/MM/YY Engineering Services

    75cm 75cm

    30cm

    38cm

    210c

    m

    30cm

    76cm

    300c

    m

    285c

    m

    225c

    m60

    cm

    30cm

    75cm

    75cm

    DD/MM/YY

    DD/MM/YY

  • 30cm

    75cm 75cm

    76cm

    75cm

    75cm

    32cm38cm

    210c

    m120cm

    30cm

    30cm

    328c

    m

    415c

    m

    30cm

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • 30cm

    114cm

    30cm

    128c

    m

    38cm

    44cm

    64cm

    285c

    m

    395c

    m

    30cm

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • R10

    5210

    10

    23

    4.8

    10

    36

    37

    27

    15 7

    38

    10

    822

    2

    2

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. ALL DIMENSIONS IN CENTIMETERS.

  • A

    A

    DETAIL #1

    SLOPEDSURFACE

    SLOPEDSURFACEMAXIMUM 6.0%

    1.5 1.5MINIMUM

    RAMPMINIMUM

    RAMPSECTION A-A

    100mm LINE

    100mm LINE300mm LINE

    0.6

    1.0

    2.5m MINIMUM (4.0m DESIRABLE)

    DETAIL SHOWINGCROSSWALK DIMENSIONS

    R=1.5

    R=1.5 R=1.5

    R=1.5

    R=12R=12

    R=3.0

    R=60R=60

    1.5m SIDEWALK1.5m SIDEWALK

    1.5m SIDEWALK1.5m SIDEWALK

    SEE DETAIL 2DETAIL #2

    1:250

    N.T.S.

    1:500

    TOP OF CURB

    10cm X 3m WIDTH 10cm X 3m WIDTH WHITE THERMOPLASTIC

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. SIDEWALK RAMPS MUST PROVIDE ACCESS DIRECTLY TO

    CROSSWALKS.2. THE SECTION OF CURB RAMP TYPE OS DEPENDANT ON THE

    LOCATION OF THE CROSSWALK RELATIVE TO THE CURB FACE.WHERE THE CURB RETURN RADIUS IS GREATER THAN OREQUAL TO 4.0m, ONE TYPE 2 RAMP CAN BE USED. WHERE THECURB RETURN RADIUS IS LESS THAN 4.0m, TYPE 1 RAMPS AREREQUIRED.

    3. WHERE CROSSWALKS ARE CONTROLLED BY SIGNALS WITH APUSH-BUTTON SYSTEM, THE SIDEWALKS AND RAMPS MUSTALLOW ACCESS BY WHEELCHAIR TO THE PUSH-BUTTON.

    4. REFER TO DRAWINGS 4.6 & 4.7 FOR DETAIL OF TYPE 1 ANDTYPE 2 RAMPS.

    5. ON A SHARP CORNER WHERE TWO TYPE 1 RAMPS ARE BEINGUSED, THE SLOPE ON THE FLARED AREAS CAN BE LESS THANTHE 8% MAX SLOPE SHOWN. THIS WILL PROVIDE A SMOOTHERSIDEWALK FOR GENERAL USE, ESPECIALLY FOR PEDESTRIANSWHO ARE NOT USING THE CROSSWALK.

    6. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE NOTED.

    FACE OFCURB

    LIP OFGUTTER

    3.5mLANES

    SEEDETAIL 1

    SIDEWALKSURFACE

    SLOPEDSURFACE

    MAXIMUM 6.0%

  • 200

    20025

    300

    75

    100

    ROD AT TIE-INS

    75

    100

    150

    25

    300

    EXTR

    UD

    ED

    SEC

    TIO

    N

    STANDARD BARRIER CURB

    CURB CROSSING BARRIER CURB

    FINISHED GRADE

    12.5M REINFORCING

    12.5M REINFORCINGRODS AT TIE-INS

    NOTES:

    1. ALL DIMENSIONS ARE IN MILLIMETRES.2. 30 MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75,

    AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5%-7%.

    12.5M REINFORCING ROD AT 2000 ON CENTRE

    12.5M REINFORCING ROD AT 2000 ON CENTRE

    TOP OF SUBGRADE

    TOP OF SUBGRADE

    ROAD STRUCTURE

    ROAD STRUCTURE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    15R

    180

    75

    265

    75

    200 MAX.150 MIN.

    FINISHED GRADE

    50R75

    375

    75

    EXTR

    UD

    ED

    SEC

    TIO

    N

    75

  • EXTR

    UD

    ED S

    ECTI

    ON

    15RF.

    O.C

    .

    L.O

    .G.

    DROP CURB

    NOTES:

    1. ALL DIMENSIONS ARE IN MILLIMETRES.2. 30 MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75,

    AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5%-7%.

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    15R

    25

    200

    10

    250150

    25

    215

    25

    4%

    B.O

    .C.

    L.O.G.

    T.O.C.

  • 900

    CONCRETE THRUST BLOCK

    A

    VALVE

    DRAINAGE PIT

    SECTION A-A

    150

    GATE VALVE

    WATER MAIN

    CONCRETE THRUST BLOCK

    A

    NOTE: 5.5 KG ZINC ANODE REQUIRED

    SEE DRAWING 5.10 CATHODIC PROTECTION

    TYPE 'A' VALVE FOR

    POLYETHYLENE

    6 MIL

    MECHANICALLY

    CONNECTED

    HYDRANT DRAIN

    2%

    HYDRANT

    PRECAST CONCRETE PAD

    CONCRETE THRUST

    BLOCK

    CONCRETE THRUST

    BLOCK

    OVER GRAVEL

    TO HYDRANT

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:

    1. THE HYDRANT SHALL BE PLACED ON A PRECAST 600 x

    600mm x 150 REINFORCED SULFATE-RESISTANT

    CONCRETE PAD OR A PRECAST 600 x 600 x 300

    UNREINFORCED CONCRETE PAD.

    2. A PIT FOR DRAINAGE 900 WIDE x 450mm LONG x 450 DEEP

    SHALL BE EXCAVATED AT THE FOOT OF THE HYDRANT

    3. THE SPACE AROUND THE BARREL AND 150mm ABOVE THE

    HYDRANT DRAIN SHALL BE FILLED WITH WASHED ROCK.

    4. 6MiL POLYETHYLENE SHALL BE PLACED OVER THE TOP OF

    THE WASHED ROCK TO PREVENT THE VOIDS FROM BEING

    FILLED WITH CLAY.

    5. BOTTOM OF HYDRANT FLANGE TO BE MINIMUM 50mm

    ABOVE TOP OF SIDEWALK FOR MAINTENANCE SERVICE.

    6. IN HIGH WATER TABLE AREAS ENSURE HYDRANT COMES

    WITH DRAIN PLUG AND PLUG IS INSTALLED.

    7. IF DRAIN PLUG IS INSTALLED; MARK HYDRANT WITH A

    50mm x 50mm BLUE SQUARE ON HYDRANT BODY, VISIBLE

    FROM ROAD.

    450

    450

    350+/-

    50mm

    PLAN

    PLUMPER PORT FACING

    THE ROADWAY

    13/05/15

    CAST IRON VALVE BOX

    HARD SURFACE

    TYPE 'C' VALVE FOR

    LANDSCAPED SURFACE

    VALVE STEM COMPLETE

    WITH ROCK GUARD

  • DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    P

    L

    GOOSE NECK

    SIDEWALKC

    OV

    ER

    M

    IN

    .

    PIPE MATERIAL NOTES:

    1. FOR 25mm PIPE DIAMETERS - USE TYPE K COPPER, PEXa

    (CROSS LINKED POLYETHYLENE), PEX-AL-PEX OR ACCEPTED

    ALTERNATE.

    2. FOR 50mm PIPE DIAMETERS - USE TYPE K COPPER PIPE OR

    ACCEPTED ALTERNATIVE.

    3. PIPE CLAMP TO BE ALL BRASS OR ACCEPTED ALTERNATE.

    4. PEXa PIPE REQUIRES 2" STAINLESS STEEL INSERTS BE

    PLACED ON BOTH SIDES OF THE "CC" CONNECTION.

    GENERAL NOTES:

    1. GOOSENECK IS REQUIRED AT SEWER CROSSINGS AND ARE

    TO BE BEDDED WITH SAND AND SANDBAGS.

    2. MAINSTOP TAPS SHALL BE A MIN. OF 600mm APART, AND NO

    LESS THAN 300mm TO A COUPLING OR COLLAR.

    3. WATER SERVICE SHALL BE ONE CONTINUOUS LENGTH.

    4. INVERT ELEVATION AT STUBBED END SHALL BE 3.0m BELOW

    ESTABLISHED FINISHED GRADE.

    5. NO HORIZONTAL GOOSENECK REQUIRED AT MAINSTOP.

    6. TAP INTO UPPER PORTION OF WATER MAIN, AT 10 AND 2

    O'CLOCK POSITIONS.

    7. HOME BUILDER TO INSTALL A COUPLING TO THE TERMINUS OF

    THE HOUSE SERVICE WHIP EXPOSED AT SURFACE AND

    CONTINUE THE WATER SERVICE TO THE HOUSE.

    8. CATHODIC PROTECTION MAY BE A REQUIREMENT IN AREAS

    OF HOT SOILS. ENSURE TO WET ANODE PRIOR TO BACKFILL.

    EXISTING SEWER MAIN

    300m

    m S

    AN

    D

    1.0

    0.15

    2-4m

    EASEMENT

    STAINLESS STEEL

    OPERATING SPINDLE

    C/W BRASS CLEVIS

    "CC" TO BE SUPPORTED UPON

    A SINGLE CHANNEL RECYCLED

    PLASTIC BLOCK (MIN. 40x200x200mm).

    - DO NOT STRAP/BOLT THE "CC"

    TO THE SUPPORTING BLOCK UNLESS

    "CC" CHAIR IS DENSO WRAPPED.

    - SET THE "CC" CENTERED

    UPON THE SUPPORTING BLOCK

    AND USE BACKFILL MATERIAL

    TO SET THE "CC" PLUMB.

    WATERMAIN

    MAINSTOP TAPPED

    AT CROWN OF MAIN

    WITH 1 TO 3 THREADS

    SHOWING

    DETAIL

    SECTION

    DETAIL

    PVC PIPE

    WHEN CITY OF ST. ALBERT BRASS CAP OF THE "CC"

    FALLS WITHIN CONCRETE, ENCLOSE IT WITH A SECTION

    OF 100mm PVC PIPE, (I.E. ON A DRIVEWAY)

    50 x 100 x 1500mm

    WOOD STAKE

    TOP 1.0m PAINTED

    FLOURESCENT RED

    "CC"

    GALVANIZED SLIDING

    UPPER SECTION

    22/06/15

    GALVANIZED SLIDING

    LOWER SECTION

    0.5

    EPOXY COATED BOOT

    TO BE DENSO WRAPPED

    PRIOR TO PLACEMENT

    OF WASHED ROCK

    WASHED ROCK

    DRAINAGE PIT

    DRAINAGE PIT NOTES:

    1. PIT EXCAVATION DIMENSIONS = 300mm LONG x 300mm WIDE x

    150mm DEEP BELOW THE "CC" AND SUPPORTING BLOCK.

    2.

    3. PLACE SUPPORTING BLOCK AND "CC" ASSEMBLY.

    4. FILL SPACE AROUND DENSO WRAPPED EPOXY COATED BOOT

    WITH WASHED ROCK TO THE TOP OF THE BOOT (200mm).

    5. COVER THE WASHED ROCK WITH 6 MIL POLYETHYLENE PRIOR TO

    BACKFILL TO PREVENT VOIDS FROM BEING FILLED WITH CLAY.

    0.2

    0.15

    0.3

    6 MIL

    POLYETHYLENE

    OVER WASHED

    ROCK

    25mm BRASS CAP

    CAP SANITARY

    SERVICE WITH

    REDUCER

    SERVICE INSTALLED

    AT MIN. 2% SLOPE

  • DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    GOOSE NECK

    CO

    VE

    R M

    IN

    .

    PIPE MATERIAL NOTES:

    1. FOR 50mm PIPE DIAMETERS - USE TYPE K COPPER PIPE OR

    ACCEPTED ALTERNATIVE.

    2. PIPE CLAMP TO BE ALL BRASS OR ACCEPTED ALTERNATE.

    GENERAL NOTES:

    1. GOOSENECK IS REQUIRED AT SEWER CROSSINGS AND ARE

    TO BE BEDDED WITH SAND AND SANDBAGS.

    2. MAINSTOP TAPS SHALL BE A MIN. OF 600mm APART, AND NO

    LESS THAN 300mm TO A COUPLING OR COLLAR.

    3. WATER SERVICE SHALL BE ONE CONTINUOUS LENGTH.

    4. INVERT ELEVATION AT STUBBED END SHALL BE 3.0m BELOW

    ESTABLISHED FINISHED GRADE.

    5. NO HORIZONTAL GOOSENECK REQUIRED AT MAINSTOP.

    6. TAP INTO UPPER PORTION OF WATER MAIN, AT 10 AND 2

    O'CLOCK POSITIONS.

    7. CATHODIC PROTECTION MAY BE A REQUIREMENT IN AREAS

    OF HOT SOILS. ENSURE TO WET ANODE PRIOR TO BACKFILL.

    EXISTING SEWER MAIN

    300m

    m S

    AN

    D

    STAINLESS STEEL

    OPERATING SPINDLE

    C/W BRASS CLEVIS

    "CC" TO BE SUPPORTED UPON

    A SINGLE CHANNEL RECYCLED

    PLASTIC BLOCK (MIN. 40x200x200mm).

    - DO NOT STRAP/BOLT THE "CC"

    TO THE SUPPORTING BLOCK UNLESS

    "CC" SADDLE IS DENSO WRAPPED.

    - SET THE "CC" CENTERED

    UPON THE SUPPORTING BLOCK

    AND USE BACKFILL MATERIAL

    TO SET THE "CC" PLUMB.

    WATERMAIN

    MAINSTOP TAPPED

    AT CROWN OF MAIN

    WITH 1 TO 3 THREADS

    SHOWING

    DETAIL

    SECTION

    DETAIL

    PVC PIPE

    WHEN CITY OF ST. ALBERT BRASS CAP OF THE "CC"

    FALLS WITHIN CONCRETE, ENCLOSE IT WITH A SECTION

    OF 100mm PVC PIPE, (I.E. ON A DRIVEWAY).

    "CC"

    GALVANIZED SLIDING

    UPPER SECTION

    22/06/2015

    GALVANIZED SLIDING

    LOWER SECTION

    EPOXY COATED BOOT

    TO BE DENSO WRAPPED

    PRIOR TO PLACEMENT

    OF WASHED ROCK.

    WASHED ROCK

    DRAINAGE PIT

    DRAINAGE PIT NOTES:

    1. PIT EXCAVATION DIMENSIONS = 300mm LONG x 300mm WIDE x

    150mm DEEP BELOW THE "CC" AND SUPPORTING BLOCK.

    2.

    3. PLACE SUPPORTING BLOCK AND "CC" ASSEMBLY.

    4. FILL SPACE AROUND DENSO WRAPPED EPOXY COATED BOOT

    WITH WASHED ROCK TO THE TOP OF THE BOOT (200mm).

    5. COVER THE WASHED ROCK WITH 6 MIL POLYETHYLENE PRIOR TO

    BACKFILL TO PREVENT VOIDS FROM BEING FILLED WITH CLAY.

    0.2

    0.15

    0.3

    6 MIL

    POLYETHYLENE

    OVER WASHED

    ROCK

    50mm BRASS CAP

  • CAST IRON VALVE BOX

    (PVC VALVE BOXES

    ARE NOT ACCEPTABLE)

    VALVE STEM COMPLETE

    WITH ROCKGUARD

    SAND OR APPROVED BACKFILL

    MATERIAL TO BE FILLED

    AROUND VALVE UP TO FLANGE

    AND FIRMLY TAMPED INTO PLACE.

    PLATFORM NOT TO REST ON ANY

    PART OF VALVE OR PIPE.

    50 X 100 X

    600 CONCRETE

    BLOCKING

    NOTES:

    1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%

    2. CONCRETE THRUST BLOCK REQUIRED FOR ALL WATER SERVICES GREATER THAN OR EQUAL TO 100m DIAMETER.

    3. HOT TAP VALVE AND SLEEVE TO BE DENSO-WRAPPED, CATHODICALLY PROTECTED, LEFT IN OPEN POSITION AND

    BURIED WITHOUT ROD OR BOX.

    WATER SHUT OFF VALVE

    SHALL BE TYPE 'A' (SHOWN)

    IN HARD SURFACES OR TYPE

    'C' IN LANDSCAPED AREAS.

    SEE NOTE 3

    CATHODIC PROTECTION

    5.5kg ZINC ANODE

    CONCRETE THRUST

    BLOCK

    MIN. DEPTH OF COVER 2.60m

    MAX. 2.90m

    SECT: TYPICAL TVS CONNECTION

    (TAPPING VALVE SLEEVE)

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    13/05/15

    DENSO-WRAP VALVE

    DENSO-WRAP VALVE

  • NO

    TE

    S:

    1. F

    OR

    C

    ON

    NE

    CT

    IO

    N T

    O T

    HE

    150m

    m S

    TO

    RM

    S

    ER

    VIC

    E R

    EF

    ER

    T

    O S

    TA

    ND

    AR

    D D

    RA

    WIN

    G N

    o. 7.6.

    2. P

    LA

    CE

    150 m

    m S

    TO

    RM

    S

    ER

    VIC

    E U

    PO

    N A

    N IN

    DE

    PE

    ND

    EN

    T LE

    DG

    E M

    IN

    IM

    UM

    0.5 m

    A

    BO

    VE

    S

    AN

    IT

    AR

    Y S

    ER

    VIC

    E IN

    VE

    RT

    .

    3. P

    IP

    E A

    LIG

    NM

    EN

    T T

    O B

    E W

    AT

    ER

    , S

    AN

    IT

    AR

    Y T

    HE

    N S

    TO

    RM

    S

    TA

    RT

    IN

    G F

    RO

    M D

    RIV

    EW

    AY

    .

    4. E

    NS

    UR

    E S

    TO

    RM

    S

    ER

    VIC

    E IS

    IN

    ST

    ALLE

    D U

    PO

    N A

    N IN

    DE

    PE

    ND

    EN

    T LE

    DG

    E A

    BO

    VE

    S

    AN

    IT

    AR

    Y A

    ND

    W

    AT

    ER

    .

    LE

    GE

    ND

    :

    R

    ED

    M

    AR

    KE

    R P

    OS

    T 2X

    4

    P

    LU

    G

    5. D

    IM

    EN

    SIO

    NS

    A

    RE

    IN

    M

    ET

    RE

    S U

    NLE

    SS

    O

    TH

    ER

    WIS

    E N

    OT

    ED

    .

    6. H

    OU

    SE

    O

    RIE

    NT

    AT

    IO

    N M

    AY

    V

    AR

    Y.

    7. S

    ER

    VIC

    E C

    ON

    NE

    CT

    IO

    NS

    S

    HA

    LL B

    E E

    XT

    EN

    DE

    D B

    EY

    ON

    D T

    HE

    G

    AS

    LIN

    E IN

    TO

    T

    HE

    LO

    T

    TO

    T

    ER

    MIN

    AT

    E A

    T 0.15 m

    F

    RO

    M T

    HE

    LO

    T E

    AS

    EM

    EN

    T B

    OU

    ND

    AR

    Y.

    8. R

    ED

    UC

    E T

    HE

    150 m

    m S

    AN

    IT

    AR

    Y S

    ER

    VIC

    E D

    OW

    N T

    O 100 m

    m A

    ND

    C

    AP

    T

    HE

    P

    LU

    G.

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    GA

    SG

    AS

    FA

    CE

    O

    F C

    UR

    BD

    RIV

    EW

    AY

    A

    PR

    ON

    TYPICAL DRIVEWAY

    PROPERTY LINE

    PR

    OP

    ER

    TY

    L

    IN

    E

    LOCATION

    VARIES

    UTILITY R.O.W.

    25

    m

    m W

    AT

    ER

    S

    ER

    VIC

    E

    15

    0 m

    m

    15

    0 m

    m

    CU

    RB

    S

    TO

    P (T

    YP

    )

    1.5

    0.15

    1.0

    SA

    NIT

    AR

    Y S

    ER

    VIC

    E

    5.0

    VA

    RIE

    S

    FR

    OM

    1

    .3

    5

    TO

    2

    .0

    15

    0 m

    m S

    HA

    LL

    OW

    S

    TO

    RM

    (3

    rd

    p

    ip

    e - if p

    re

    se

    nt)

    ST

    OR

    M S

    ER

    VIC

    E

    25

    m

    m W

    AT

    ER

    S

    ER

    VIC

    E

    15

    0 m

    m

    SA

    NIT

    AR

    Y S

    ER

    VIC

    E

    DR

    IV

    EW

    AY

    A

    PR

    ON

    2.02.5

    6.5

    WA

    TE

    RM

    AIN

    SA

    NIT

    AR

    Y S

    EW

    ER

    1.5

    0.3

    0.3

    0.3

    0.3

    TY

    PIC

    AL H

    OU

    SE

    LO

    CA

    TIO

    NT

    YP

    IC

    AL H

    OU

    SE

    LO

    CA

    TIO

    N

    ST

    OP

    (T

    YP

    )C

    UR

    B

    0.15

    WA

    TE

    R S

    ER

    VIC

    E 25 m

    m

    SA

    NIT

    AR

    Y S

    ER

    VIC

    E 150 m

    m

    ST

    OR

    M S

    ER

    VIC

    E 150 m

    m

    2.6

    2.3

    MIN

    2.0

    MIN

    2.0

    2.6

    2.3

    RO

    AD

    S

    ID

    E 'A

    '

    WIT

    H 6.5m

    B

    OU

    LE

    VA

    RD

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    SID

    EW

    AL

    K

    TYPICAL DRIVEWAY

    LOCATION

    PROPERTY LINE

    9. S

    AN

    IT

    AR

    Y A

    ND

    W

    AT

    ER

    S

    ER

    VIC

    ES

    S

    HA

    LL B

    E P

    LA

    CE

    D A

    T A

    D

    EP

    TH

    O

    F B

    UR

    Y O

    F 3.0 m

    A

    T P

    RO

    PE

    RT

    Y LIN

    E.

    10. S

    AN

    IT

    AR

    Y A

    ND

    S

    TO

    RM

    S

    ER

    VIC

    ES

    M

    US

    T H

    AV

    E A

    M

    IN

    IM

    UM

    C

    ON

    TIN

    UO

    US

    G

    RA

    DE

    O

    F 2%

    F

    RO

    M T

    HE

    M

    AIN

    T

    O P

    RO

    PE

    RT

    Y LIN

    E.

  • FA

    CE

    O

    F C

    UR

    B

    DR

    IV

    EW

    AY

    A

    PR

    ON

    TYPICAL DRIVEWAY

    PROPERTY LINE

    PR

    OP

    ER

    TY

    L

    IN

    E

    LOCATION

    VARIES

    UTILITY R.O.W.

    15

    0 m

    m

    1.5

    0.15

    1.0

    0.5

    4.5

    VA

    RIE

    S

    FR

    OM

    1

    .3

    5

    TO

    2

    .0

    ST

    OR

    M S

    EW

    ER

    ST

    OR

    M S

    ER

    VIC

    E

    PROPERTY LINE

    25

    m

    m W

    AT

    ER

    S

    ER

    VIC

    E

    15

    0 m

    m S

    AN

    IT

    AR

    Y S

    ER

    VIC

    E

    DR

    IV

    EW

    AY

    A

    PR

    ON

    LOCATION

    TYPICAL DRIVEWAY

    3.0

    0.3

    0.3

    0.3

    0.3

    TY

    PIC

    AL H

    OU

    SE

    LO

    CA

    TIO

    NT

    YP

    IC

    AL H

    OU

    SE

    LO

    CA

    TIO

    N

    CU

    RB

    S

    TO

    P (T

    YP

    )

    0.15

    NO

    TE

    S:

    1. F

    OR

    C

    ON

    NE

    CT

    IO

    N T

    O T

    HE

    150m

    m S

    TO

    RM

    S

    ER

    VIC

    E R

    EF

    ER

    T

    O S

    TA

    ND

    AR

    D D

    RA

    WIN

    G #7.6

    2. P

    LA

    CE

    150 m

    m S

    TO

    RM

    S

    ER

    VIC

    E U

    PO

    N A

    N IN

    DE

    PE

    ND

    EN

    T LE

    DG

    E M

    IN

    IM

    UM

    0.5 m

    A

    BO

    VE

    S

    AN

    IT

    AR

    Y S

    ER

    VIC

    E IN

    VE

    RT

    .

    3. P

    IP

    E A

    LIG

    NM

    EN

    T T

    O B

    E W

    AT

    ER

    , S

    AN

    IT

    AR

    Y T

    HE

    N S

    TO

    RM

    S

    TA

    RT

    IN

    G F

    RO

    M D

    RIV

    EW

    AY

    .

    4. E

    NS

    UR

    E S

    TO

    RM

    S

    ER

    VIC

    E IS

    IN

    ST

    ALLE

    D U

    PO

    N A

    N IN

    DE

    PE

    ND

    EN

    T LE

    DG

    E A

    BO

    VE

    S

    AN

    IT

    AR

    Y A

    ND

    W

    AT

    ER

    .

    LE

    GE

    ND

    :

    R

    ED

    M

    AR

    KE

    R P

    OS

    T 2X

    4

    P

    LU

    G

    5. D

    IM

    EN

    SIO

    NS

    A

    RE

    IN

    M

    ET

    RE

    S U

    NLE

    SS

    O

    TH

    ER

    WIS

    E N

    OT

    ED

    .

    6. H

    OU

    SE

    O

    RIE

    NT

    AT

    IO

    N M

    AY

    V

    AR

    Y.

    7. S

    ER

    VIC

    E C

    ON

    NE

    CT

    IO

    NS

    S

    HA

    LL B

    E E

    XT

    EN

    DE

    D B

    EY

    ON

    D T

    HE

    G

    AS

    LIN

    E IN

    TO

    T

    HE

    LO

    T

    TO

    T

    ER

    MIN

    AT

    E A

    T 0.15 m

    F

    RO

    M T

    HE

    LO

    T E

    AS

    EM

    EN

    T B

    OU

    ND

    AR

    Y.

    WA

    TE

    R S

    ER

    VIC

    E 25 m

    m

    SA

    NIT

    AR

    Y S

    ER

    VIC

    E 150 m

    m

    ST

    OR

    M S

    ER

    VIC

    E 150 m

    m

    2.6

    2.3

    MIN

    2

    .0

    MIN

    2

    .0

    2.6

    2.3

    15

    0 m

    m S

    AN

    IT

    AR

    Y S

    ER

    VIC

    E

    CU

    RB

    S

    TO

    P (T

    YP

    )

    25

    m

    m W

    AT

    ER

    S

    ER

    VIC

    E

    RO

    AD

    S

    ID

    E 'B

    '

    WIT

    H 4.5m

    B

    OU

    LE

    VA

    RD

    Date:

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY

    01/04/13

    Engineering Municipal Standards

    12/06/15

    SID

    EW

    AL

    K

    8. R

    ED

    UC

    E T

    HE

    150 m

    m S

    AN

    IT

    AR

    Y S

    ER

    VIC

    E D

    OW

    N T

    O 100 m

    m A

    ND

    C

    AP

    T

    HE

    P

    LU

    G.

    10. S

    AN

    IT

    AR

    Y A

    ND

    S

    TO

    RM

    S

    ER

    VIC

    ES

    M

    US

    T H

    AV

    E A

    M

    IN

    IM

    UM

    C

    ON

    TIN

    UO

    US

    G

    RA

    DE

    O

    F 2%

    F

    RO

    M T

    HE

    M

    AIN

    T

    O T

    HE

    P

    RO

    PE

    RT

    Y LIN

    E.

    9. S

    AN

    IT

    AR

    Y A

    ND

    W

    AT

    ER

    S

    ER

    VIC

    ES

    S

    HA

    LL B

    E P

    LA

    CE

    D A

    T A

    T D

    EP

    TH

    O

    F B

    UR

    Y O

    F 3.0 m

    A

    T P

    RO

    PE

    RT

    Y LIN

    E.

  • SECTION A-A

    PLAN

    A A

    300

    431

    WA

    TE

    R

    184

    165

    127

    48

    57

    CAST IRON VALVE BOX

    VALVE STEM COMPLETE

    WITH ROCKGUARD

    SAND OF APPROVED BACKFILL MATERIAL

    TO BE FILLED AROUND VALVE UP TO FLANGE

    AND FIRMLY TAMPED INTO PLACE. PLATFORM

    NOT TO REST ON ANY PART OF VALVE OR PIPE

    50 X 100 X 600 CONCRETE BLOCKING

    VALVE BOX SUPPORT PLATFORM CONSISTS OF 2-3

    LAYERS OF RECYCLED PLASTIC TIMBERS

    (2x4" OR 2x6" OR 2x8" OR SIMILAR).

    PLATFORM SHALL BE TAILORED TO VALVE TYPE AND

    HELD TOGETHER BY NAILS OR SCREWS.

    PLACE PLATFORM UPON ON TAMPED SAND AT LEVEL

    WITH THE FLANGE ON THE VALVE.

    (NOTE IF RECYCLED PLASTIC TIMBERS ARE NOT READILY

    AVAILABLE, THEN PRESSURE TREATED TIMBERS MAY BE

    USED AS AN ALTERNATE MATERIAL).

    CORED HANDHOLES

    STANDARD WATER PLUG

    NOTES:

    1. VALVE BOXES SHALL BE EXTERNALLY AND INTERNALLY COATED WITH ASPHALT OR EPOXY COATING.

    2. PVC VALVE BOXES ARE NOT PERMITTED.

    3. FOR CATHODIC PROTECTION SEE DWG. No. 5.9

    4. ALL DIMENSIONS IN MILLIMETERS UNLESS OTHERWISE NOTED.

    WATER MAIN OR HYDRANT LEAD

    MIN

    . D

    EP

    TH

    O

    F C

    OV

    ER

    2.65m

    Date:

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY

    01/04/13

    Engineering Municipal Standards

    22/06/15

    VALVE BOX SUPPORT PLATFORM

  • PVC

    5.5 kg (12 lbs)ZINC ANODE

    50mm

    VALVE

    ZINC ANODE5.5 kg ( 12 lb)

    CROSS

    PVC

    50mm

    FITTING

    BEDDING

    ANODE WIRE

    PVC

    DETAIL

    ANODE

    VALVE

    5.5 kg (12lb)ZINC ANODE

    PVC

    50m

    m PVC

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    REPLACE ANDCOMPACT CLAY

    NOTES:1. ALL ANODES TO BE 5.5kg ZINC.2. INSTALL ANODE AT PIPE DEPTH IN NATIVE SOIL.3. MIN. DISTANCE FROM ANODE TO PIPE IS 150mm4. MIN. DISTANCE FROM ANODE TO THRUST BLOCK IS 300mm5. ANODES TO BE EMBEDDED IN UNDISTURBED TRENCH WALL WITH A MIN. OF

    50mm OF NATIVE CLAY COVER AROUND ANODE.6. ANODE TO BE 'WETTED' WITH WATER PRIOR TO BACKFILL TO ACTIVATE THE

    ANODE.

  • DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:1. PIPE CAMP TO BE ALL BRASS OR ACCEPTED EQUIVALENT.2. FOR PEX-AL-PEX PIPE CATHODIC CLAMP REQUIRED TO

    SPINDLE ONLY.3. ZINC ANODES TO BE EMBEDDED INTO TRENCH WALL TO

    PROVIDE FOR A MINIMUM OF 50mm NATIVE CLAY COMPLETELYCOMPACTED AROUND ANODE.

    4. ZINC ANODE TO BE "WETTED" WITH A PAIL OF WATER PRIORTO BACKFILL TO ACTIVATE THE ANODE.

    CLAMP

    ZINC ANODE

    AND COMPACTREPLACE CLAY

    505.5 kg.

    DETAIL

    PL

    GAS MAIN

    GOOSE NECK

    SIDEWALK

    CO

    VE

    R M

    IN.

    EXISTING SEWER MAIN

    SHALLOWSTORM

    300m

    m S

    AN

    D

    1.0

    0.15

    1.0

    2-4mEASEMENT

    STAINLESS STEELOPERATING SPINDLEC/W BRONZE CLEVIS

    SUPPORT WITHCONCRETE BLOCK50 x 200 x 300

    5.5kg ZINCANODE

    WATERMAIN SECTION

    CLAMP

  • 600 MAX

    1200Ø

    635Ø

    SECTION A-A

    PLAN VIEW

    300 300

    5075

    20Ø SAFETY STEPS

    UNDISTURBED NATIVE SOIL ORMECHANICALLY COMPACTED TO98% S.P.D.

    FINISHED GRADEMANHOLE FRAME & COVER

    CONCRETE GRADE RINGS AS REQUIRED

    ECCENTRIC CONICAL TOP

    PRECAST CONCRETE BARRELS

    PRECAST PRE-BENCHED CONCRETE

    JOINTS

    BEDDING TOFIRST JOINT

    MANHOLE BASE C/W PIPE GASKET

    C/W CONFINED O-RING GASKET

    150°

    CL

    CLCL

    (MAX 3 FOR A TOTAL 450mm)

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    03/10/14

    NOTES:1. SAFETY STEPS TO BE SPACED AT 400 MAX.

    DISTANCE. LAST STEP TO BE 300 MAX. ABOVEBENCHING.

    2. CHANNELING AND BENCHING TO BE FINISHEDTO TROWEL SMOOTHNESS.

    3. COMPACT SAND BACKFILL AROUNDMANHOLES TO A MINIMUM OF 98% S.P.D. INLIFTS NOT EXCEEDING 150 MIN.

    4. FLAT TOP SECTION TO BE USED FORSHALLOW BURY MANHOLES OF UP TO 1.80m.

    5. ALL JOINTS TO BE SET WITH RUBBER GASKETAND FINISHED WITH NON-SHRINK GROUTINSIDE AND OUTSIDE FOR FULLCIRCUMFERENCE.

    6. THE PLACEMENT OF THE FIRST LADDERRUNG CAN VARY (BARREL SECTION ORGRADE RING INSERT) BUT MUST NOT EXCEED600MM FROM RIM TO FIRST RUNG.

    7. GRADE RINGS MUST BE SET PLUMB TO THEBARREL AND NOT BE STAGGERED.

    50-75mm PROJECTIONINTO MANHOLE

    WATERTIGHT

    MORTARED INSIDE AND OUT

  • 25 MPa CONCRETE

    SECTION A-A

    PLAN

    A A

    COVER LOCATION

    MORTARED INSIDE AND OUT

    d

    300

    20Ø SAFETY STEPS

    75

    300

    50

    NOTE:MATCH CROWNS

    (MAX 3 FOR A TOTAL 450mm)CONCRETE GRADE RINGS AS REQUIRED

    1800

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    03/10/14

    NOTES:1. d = 600mmØ TO 1050mmØ2. WHERE UNSUITABLE TRENCH

    CONDITIONS EXIST, CRUSHED ROCKWILL BE REQUIRED IN PLACE OFBEDDING MATERIAL BENEATHMANHOLE BASE.

    3. FLAT TOP SECTION TO BE USED FORSHALLOW BURY MANHOLES OF UP TO1.80m.

    4. SAFETY STEPS TO BE SPACED AT 400MAX. DISTANCE LAST STEP TO BE 300MAX. ABOVE BENCHING.

    5. CHANNELING AND BENCHING TO BEFINISHED TO TROWEL SMOOTHNESS.

    6. COMPACT SAND BACKFILL AROUNDMANHOLES TO A MINIMUM OF 98%S.P.D. IN LIFT NOT EXCEEDING 150 MIN.

    7. ALL JOINTS TO BE SET WITH RUBBERGASKET AND FINISHED WITHNON-SHRINK GROUT INSIDE ANDOUTSIDE FOR FULL CIRCUMFERENCE.

    8. THE PLACEMENT OF THE FIRSTLADDER RUNG CAN VARY (BARRELSECTION OR GRADE RING INSERT) BUTMUST NOT EXCEED 600MM FROM RIMTO FIRST RUNG.

    9. GRADE RINGS MUST BE SET PLUMB TOTHE BARREL AND NOT BE STAGGERED.

    FINISHED GRADE

    VARIES

    600MAX

    100MIN

    200 MIN

    200 MIN

    CEMENTMORTAR

    50-75mmPROJECTIONINTOMANHOLE

  • NOTES:

    COVER

    SECTION A-A

    B B

    A

    A

    1200Ø BARREL

    GROUT INSIDE & OUTSIDERUBBER GASKET JOINTS

    APPROVEDMANHOLE STEPS

    CLASS A 25MPa

    1200 M

    IN. DIA

    . PIPE

    SECTION B-B

    1200Ø

    3050 CLASS A BEDDING

    BEDDING

    MIN. 150MIN. 150

    UNDISTURBED NATIVE SOILOR MECHANICALLY COMPACTED TO98% S.P.D..

    1200 Ø

    1. THIS TYPE OF MANHOLE IS TO BE BUILT ONLY ON MAINS OF1200mm DIAMETER OR LARGER AND WHERE THERE IS NOCHANGE IN DIRECTION OF FLOW, I.E. A"STRAIGHT-THROUGH" FLOW.

    2. SAFETY STEPS TO BE SPACED AT 400 MAX. DISTANCE. LASTSTEP TO BE 300 MAX. ABOVE BENCHING.

    3. FLAT TOP SECTION TO BE USED FOR SHALLOW BURYMANHOLES OF UP TO 1.80m.

    4. CHANNELING AND BENCHING TO BE FINISHED TO TROWELSMOOTHNESS.

    5. COMPACT SAND BACKFILL AROUND MANHOLES TO AMINIMUM OF 98% S.P.D. IN LIFTS NOT EXCEEDING 150 MIN.

    6. ALL JOINTS TO BE SET WITH RUBBER GASKET AND FINISHEDWITH NON-SHRINK GROUT INSIDE AND OUTSIDE FOR FULLCIRCUMFERENCE.

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • A

    SECTION A-A

    A

    150 150

    PLAN SECTION B-B

    TEE FITTING, DIAMETER ASINCOMING SEWER

    INCOMING SEWER

    B B

    1:12 SLOPE

    MIN. 200

    PIPE BELL REQUIRED AT CONCRETE FACE.

    1200Ø

    CLASS A BEDDING (25MPa CONCRETE)

    NOTES:1. PRECAST CONCRETE COMPONENTS TO MEET CURRENT A.S.T.M. C478 STANDARDS.2. CAST IN PLACE CONCRETE TO BE 25 MPa AT 28 DAYS.3. CHANNELING AND BENCHING TO BE FINISHED TO TROWEL SMOOTHNESS.4. COMPACT BACKFILL AROUND MANHOLES TO A MINIMUM OF 98% STANDARD PROCTOR DENSITY.

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

  • INTO MAIN SEWER

    FORMING SMOOTH FLOW CHANNEL

    ELBOW AND BENCH TO MID-HEIGHT

    PROVIDE CONCRETE SUPPORT FOR

    TO SECURE DROP PIPE

    PIPE STRAPS @ MIN. 500 O/C

    USE STAINLESS STEEL

    INLET SEWER

    MIN. 50 DROP

    R=450min. AND

    SEWER

    INLET

    SIZE AS INLET SEWER

    PVC DROP PIPE- SAME

    SECTION A-A

    1

    12

    SLOPED UPWARD TO MH

    MID-HEIGHT OF PIPE AND

    BENCHING TO AT LEAST

    USE PRE-BENCHED BASE

    MANHOLE BARREL

    FLO

    W C

    HA

    NN

    EL

    WALL AT 1:12

    6 x 40 STAINLESS STEEL STRAPS

    ANCHOR BOLTS

    EXPANSION TYPE

    BRACKET DETAIL

    PIPE INVERT

    AA

    TEE

    DD/MM/YY

    DD/MM/YY

    Engineering Services

    DD/MM/YY Engineering Municipal Standards

    NOTES:

    1. MAXIMUM INLET SEWER OF 250 DIA.

    2. DROP PIPE SIZE TO EQUAL INLET SIZE.

    3. TEE FITTING TO BE APPROVED PRIOR TO ORDERING.

    4. CAST IN PLACE CONCRETE 25 MPa IN 28 DAYS.

    5. MANHOLE BASE TO BE PRE-BENCHED.

    6. FOR SANITARY SEWER - MIN DROP 0.75m TO MAX 3.0m THEN EXTERNAL DROP.

    7. FOR STORM SEWER - MIN DROP 1.5m TO MAX 3.0m THEN EXTERNAL DROP.

    0.75m MIN TO 3.0m MAX

    1200 MIN

    SECTION THROUGH MANHOLE

  • SLAB TOP TO SUIT FRAME AND COVER

    COMPACTED TO 98% S.P.D.APPROVED GRANULAR MATERIAL

    PIPE TO BE USED WHERE LEADGRADE. (FULL LENGTH OFLEAD @ MINIMUM OF 1.0%

    ENTERS CATCH BASIN)

    MIN. 250 DIAMETER CATCH BASIN

    PRECAST CONCRETE BASE

    600 MIN. SUMP

    900Ø

    1500 mm MIN.

    LC

    UNDISTURBED NATIVE SOIL ORMECHANICALLY COMPACTEDTO 98% S.P.D.

    WATERTIGHT JOINTS WITH

    PIPE

    CL

    O RINGS GASKETSPRECAST JOINTS C/W CONFINED

    NON-SHRINKING GROUT INSIDE AND OUTSIDE FOR FULL CIRCUMFERENCE

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    03/10/14

    NOTES:1. PRECAST CONCRETE COMPONENTS TO MEET CURRENT A.S.T.M. C478 STANDARDS.2. CAST IN PLACE CONCRETE TO BE 25 MPa AT 28 DAYS.3. ALL GRADE RING JOINTS TO BE FINISHED WITH RAM NECK MATERIAL AND FINISHED WITH

    NON-SHRINK GROUT INSIDE AND OUTSIDE FOR FULL CIRCUMFERENCE. THIS INCLUDESJOINTS BETWEEN GRADE RINGS, GRADE RINGS AND FRAMES, AND BETWEEN GRADERINGS AND SLAB TOPS.

    4. ALL BARREL JOINTS TO BE RUBBER GASKET WITH NON-SHRINK GROUT INSIDE & OUT.5. ALL WICK DRAINS TO EXTEND 100mm - 150mm INTO CATCH BASIN.6. GRADE RINGS MUST BE SET PLUMB TO THE BARREL AND NOT BE STAGGERED.

    K-7 FRAME AND COVER

    CONCRETE GRADE RINGS AS REQUIRED(MAX 3 FOR A TOTAL OF 450mm)

    50-75mm

    MORTARED INSIDE AND OUT

  • BACK OF TOP OF CURB

    FACE OF CURB

    LIP OF GUTTER

    PRECAST

    900 Ø PRECAST CONCRETECATCH BASIN BARREL

    MIN 250Ø CATCH BASIN LEAD @ MINIMUM 1.0% GRADE

    WATERTIGHT JOINT

    SECTION B-B

    SECTION A-A

    150 MIN

    CONCRETE

    AA

    B

    B

    98% S.P.D.OR MECHANICALLY COMPACTED TO UNDISTURBED NATIVE SOLID SOIL

    900mmØ

    MIN 150

    MIN 150

    GRATE TO BE DEPRESSEDBY 40mm OR TO SECOND COURSEPAVEMENT DEPTH

    SIDE INLET TO BE RECESSED MIN 25mmFROM FACE OF CURB

    FACE OF CURB

    WITH NON-SHRINK

    F-51 GUTTER FRAME AND GRATE

    GROUT FINISH

    1500mmMIN.

    600mm MIN.SUMP

    CL

    PRECAST CONCRETE BASE

    C/W CONFINEDO-RINGS GASKETS

    SLAB TEE TOP

    NOTES:1. WICK DRAINS TO EXTEND 100mm - 150mm INTO CATCH BASIN.2. PRECAST CONCRETE COMPONENTS TO MEET CURRENT ASTM C478 STANDARDS.3. CAST IN PLACE CONCRETE TO BE 25MPa AT 28DAYS.4. SUPPLY NORWOOD TYPE NF-51, TROJAN TYPE K-1A-2 PIECE OR APPROVED EQUIVALENT.

    (ALL JOINTS TO BE FINISHED WITH NON-SHRINK GROUTINSIDE AND OUTSIDE FOR FULL CIRCUMFERENCE.)

    DD/MM/YY

    DD/MM/YY Engineering Services

    DD/MM/YY Engineering Municipal Standards

    23/04/2014

    50-75mm

    F-51 SIDE INLET FRAME AND GRATE

    (A FULL LENGTH OF PIPE SHALL BE USED WHERETHE CATCHBASIN LEAD ENTERS THE CATCHBASIN.)