CITY OF ST. ALBERTENGINEERING STANDARD
DRAWINGSAPRIIL 2014
APPENDIX A
-
Municipal Engineering Standards Drawing Index
STANDARD DRAWINGS
Drawing No. Drawing Name
Revision (M/D/Y)
PDF Page No.
3.1 Depth of Cover & Vertical Separation Between Mains 04/23/14 6 3.2 9.0m Local (Residential) 02/25/15 7 3.3 11.0m Minor Collector (Residential & Commercial) 02/25/15 8 3.4
12.0m Major Collector (Residential & Commercial) 02/25/15 9
3.5 15.0m Undivided Arterial 02/25/15 10 3.6 20.5m Divided Arterial 02/25/15 11 3.7 Left Blank Intentionally 04/01/13 12 3.8 Left Blank Intentionally 04/01/13 13 3.9 Left Blank Intentionally 04/01/13 14 3.10 Cul-de-Sac Bulb – No Walkway 04/01/13 15 3.11 Cul-de-Sac Bulb – Monolithic Sidewalk 04/01/13 16 3.12 6.0m P.U.L. - Utility Easement 04/01/13 17 3.13 P.U.L. Section 04/01/13 18 3.14 Driveway Residential Crossing - 2 Car Garage (Max 7.5m) 04/15/15 19 3.15
Driveway Residential Crossing - 3 Car Garage (Max 7.5m) 04/15/15 20
3.16 Driveway Residential Crossing – For Small Lots (
-
Municipal Engineering Standards Drawing Index
Drawing No. Drawing Name
Revision (M/D/Y)
PDF Page No.
3.29
Road Lines Template 04/01/13 36 3.30
Pedestrian Crosswalk and Stop Bar Detail 04/01/13 37
3.31
11.0m Wide Collector Zebra Stripe Crosswalk Detail 04/01/13 38 3.32
Arterial Zebra Stripe Crosswalk Detail 04/01/13 39
3.33
Stop Box Pavement Marking 04/01/13 40 3.34
Crosswalks at Signalized Intersections 04/01/13 41
3.35
Lane and Lead In Lines 04/01/13 42 3.36
Lateral Pavement Markings 04/01/13 43
3.37 Crosswalks at Intersections, With Pedestrian Actuated Signals 04/01/13 44
3.38 Crosswalks at Intersections, Midblock and T-Intersection with Pedestrian Flashers or Signs 04/01/13 45
3.39 Guide Lines 04/01/13 46 3.40 Continuity Lines 04/01/13 47 3.41 Spacing of Turn Arrows in Forced Left Turn Lane 04/01/13 48 3.42 Spacing of Turn Arrows in Forced Right Turn Lane 04/01/13 49 3.43
Spacing of Turn Arrows 04/01/13 50
3.44 Two Lane Exit Forced Right with Through Right Option 04/01/13 51 3.45 Two Lane Exit Only on Right 04/01/13 52 3.46 Pavement Edge Lines at Yields and Merge Entrances 04/01/13 53 3.47 Merging / Diverging Gore Details 04/01/13 54 3.48 Merge Area 04/01/13 55 3.49 Left Turn Bay Marking With Slab-on Island 04/01/13 56 3.50 Diverge Area Opposing Flow 04/01/13 57 3.51
Diverge Area Common Flow 04/01/13 58
3.52
Single Arrow 04/01/13 59 3.53
Double Arrow 04/01/13 60
3.54
Merging Arrow 04/01/13 61 3.55
Handicap Symbol 04/01/13 62
4.1
Extruded Concrete Sidewalk – Standard Detail 04/01/13 63 4.2 Typical Intersection Curb Ramp and Boulevard Ramp 04/01/13 64 4.3 Layout of Crosswalks and Ramps at Urban Intersections 04/01/13 65
4.4 Sidewalk Ramp for Wheelchairs and Bicycles on Corner (Type C) 04/01/13 66
-
Municipal Engineering Standards Drawing Index
Drawing No. Drawing Name
Revision (M/D/Y)
PDF Page No.
4.5 Sidewalk Ramp for Wheelchairs or Bicycles on Corner (Type A) 04/01/13 67
4.6
Intersection Islands – Minimum Size 04/01/13 68 4.7
Left Blank Intentionally 04/01/13 69
4.8
Roll Face Curb and Gutter (Mountable) 04/01/13 70 4.9
150mm Standard Reverse Curb 250mm Gutter 04/01/13 71
4.10 200mm Standard Curb with 300mm Gutter – REHAB Only 04/01/13 72 4.11
200mm Standard Curb & 500mm Gutter 04/01/13 73
4.12 Standard Barrier Curb & Curb Crossing 04/01/13 74 4.13 Drop Curb 04/01/13 75 5.1 Typical Hydrant Connection & Valve Placement 05/13/15 76
5.2A 25mm Residential Water Service Connection (“CC”) 06/22/15 77 5.2B 50mm Residential Water Service Connection (“CC”) 06/22/15 78 5.2C Typical TVS Connection (Tapping Valve Sleeve) 05/13/15 79 5.3A Typical Service Location (6.5m boulevard) 06/12/15 80 5.3B Typical Service Connection (4.5m boulevard) 06/12/15 81 5.4 Typical Water Main Valve – TYPE A 06/22/15 82 5.5 Trenching Detail 04/01/13 83 5.6 Types of Pipe Bedding and Pipe Zone Backfill 04/01/13 84 5.7 Concrete Thrust Block Details for Water Mains 04/01/13 85 5.8 Augured Service (Residential) - Installation Details 04/01/13 86 5.9 Cathodic Protection for Watermain Fittings 04/01/13 87 5.10 Cathodic Protection for Hydrants 04/01/13 88 5.11 Cathodic Protection for Typical Water Service Connection 04/01/13 89 6.1 Standard 1200mm Diameter Manhole 10/03/14 90 6.2 Typical Perched Manhole for Pipes 600mm – 1050mm DIA 10/03/14 91 6.3 T-Riser Manhole 04/01/13 92 6.4 External Drop Manhole 04/01/13 93 6.5 Internal Drop Manhole 04/01/15 94 6.6 Sanitary Sewer Service with Riser 04/01/15 95 6.7 Floating Type Manhole Frame & Cover F-80 10/03/14 96
6.8 Floating Type Manhole Frame and Cover with Gasket Seal F-90 10/03/14 97
6.9 Standard F-39 Manhole Cover Plate 10/03/14 98
-
Municipal Engineering Standards Drawing Index
Drawing No. Drawing Name
Revision (M/D/Y)
PDF Page No.
7.1 Typical 900mm Diameter Catch Basin with K-7 Frame and Cover 10/03/14 99
7.2 900mm Diameter Catch Basin with F-51 Two-Piece Frame & Cover 04/23/14 100
7.3 1200mm Diameter Catch Basin Manhole with F-38/F39 Frame and Cover 10/03/14 101
7.4 Typical Catch Basin Cover Details 04/01/13 102
7.5 K-7 Type Catch Basin 04/01/13 103 7.6 Typical Sump Pump Connection 04/01/13 104 7.7 Typical Clean Out 04/01/13 105
7.8A 3.0m Drainage Easement – Concrete Swale 500mm 06/12/15 106
7.8B 3.0m Drainage Easement – High Back Concrete Swale 750mm 06/12/15 107
7.8C 3.0m Drainage Easement – Concrete Swale 1000mm 06/12/15 108
7.9 Lot Grading 03/17/14 109 7.10 Typical Walk-Out Basement - Lot Grading 04/01/13 110 7.11 Cross Section for Storm Water Retention Lake 04/01/13 111 7.12 Wick Drain Connection to Catch Basin 04/01/13 112
-
WATERMAIN
PRIMARYPOWER
CABLE TVTELEPHONE
GAS
SANITARYSEWER
GAS
STORMSEWER
TYPICAL ROAD SECTION
ROADWAY
0.3 0.3
0.5 0.5
0.3 0.3
SANITARY STORM WATER
SANITARY STORM
WATER WATER
STORMSANITARY
MINIMUM DEPTH OF COVER
MINIMUM VERTICAL SEPARATION
NOTES1. ALL DIMENSIONS IN METRES.2. UNDER NORMAL CONDITIONS, WATER MAINS SHALL CROSS ABOVE SEWERS WITH A SUFFICIENT VERTICAL
SEPARATION TO ALLOW FOR PROPER BEDDING AND STRUCTURAL SUPPORT OF THE WATER AND SEWER MAINS.3. WHERE IT IS NECESSARY FOR THE WATERMAIN TO CROSS BELOW THE SEWER, THE WATERMAIN SHALL BE
PROTECTED BY THE FOLLOWING: i. A VERTICAL SEPARATION OF AT LEAST 0.5m FROM OUTER DIAMETER (O.D.) OF THE WATERMAIN PIPE CROWN
TO THE OUTER DIAMETER (O.D.) OF THE SEWER INVERT; ii. STRUCTURAL SUPPORT OF THE SEWER TO PREVENT EXCESSIVE JOINT DEFLECTION AND SETTLING; AND iii. CENTERING OF THE LENGTH OF WATERMAIN AT THE POINT OF CROSSING SO THAT THE JOINTS ARE
EQUIDISTANT FROM THE SEWER BEING CROSSED.
1.01.8
2.65
2.60
1.00.3
0.3
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
23/04/14
BOTTOM OF ROAD
WATERSANITARYSTORM
CROSSING DUCT
L.O.G.
MIN1.5
1.0
PRIMARYPOWER
CABLE TVTELEPHONE
FINISHED GROUND FINISHED GROUND
⅊⅊
1.0
SHALLOWSTORM
1.8
NOTES1. ALL DIMENSIONS IN METRES.2. THE MINIMUM DEPTH OF COVER FOR SANITARY, STORM AND WATER MAINS INDICATED ABOVE CONSIDER FROST
PROTECTION REQUIREMENTS ONLY.
3. THE DESIGNED DEPTH OF COVER FOR SANITARY, STORM AND WATER MAINS SHALL BE ENGINEERED WITHCONSIDERATION TO:
i. ADEQUATE DEPTH OF COVER FOR LOT SERVICES AT PROPERTY LINE.ii. OVERALL DEPTH OF COVER REQUIREMENTS FOR THE ENTIRE DEVELOPMENT AREA.iii. PIPE CROSSING CONFLICTS.
4. DIRECTIONAL DRILLING OF SHALLOW UTILITIES SHALL ADHERE TO THE DEPTH RANGE SPECIFIED FOR A ROADCROSSING DUCT.
9. SHALLOW STORM PIPES SHALL HAVE 1.8m MIN DEPTH OF COVER AND 2.9m MAX DEPTH OF COVER.
BETWEEN MAINS
PIPE CROWN
PIPE OBVERT (OBV)
PIPE INVERT (INV)
WHERE:
PIPE INNERDIAMETER (I.D.)
PIPE OUTERDIAMETER (O.D.)
WHERE:
LOG LOG
-
0.51.5 2.5
4.5 9.0
2.5 1.5 2.5
6.5
20.0
130mm PARABOLIC CROWN
WATER
MAIN
PRIMARY
POWER
CABLE TV
TELEPHONE
GAS
SANITARY
SEWER
SHALLOW
STORM
POWER
CABLE TV
TELEPHONE
1.0
2.0
1.25
3.0
R.O.W.
P
L L
P
F.O
.C
.
F.O
.C
.
LIGHT
STANDARD
HYDRANT
2.03.25
5.0
1.0
GAS
STORM
SEWER
2.0
1.5
2-4m UTILITY
R.O.W.
SEPARATE WALK (2% CROSSFALL)
NOTES:
50mm TYPE ACR ASPHALT SURFACE COURSE
75mm TYPE ACB ASPHALT BASE COURSE
250mm GRANULAR BASE COURSE
150mm MINIMUM PREPARED SUBGRADE
MINIMUM ROAD STRUCTURE
TYPICAL SECTION
SHALLOW
STORM
100mm WICK DRAIN, TIED TO CATCH BASIN
CURB & GUTTER
BACKFILL
300 mm
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
31/03/2014
25/02/2015
CURB & GUTTER
BO
ULE
VA
RD
3%
SLO
PE
2-4m UTILITY
SEPERATE WALK
(2% CROSSFALL)
BO
ULE
VA
RD
3%
SLO
PE
1. ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.
2. ALL ROAD STRUCTURES ARE SUBJECT TO THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT
AND THE FIELD CONDITIONS AT THE TIME OF CONSTRUCTION.
3. TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF THE SIGHT LINES AT
INTERSECTIONS, AND AS CLOSE TO PROPERTY LINES AS IS PRACTICABLE.
-
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
23/04/2014
25/02/2015
NOTES:
1. ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.
2. ALL ROAD STRUCTURES ARE SUBJECT TO THE RECOMMENDATIONS IN THE GEOTCHNICAL REPORT AND THE FIELD
CONDITIONS AT THE TIME OF CONSTRUCTIONS.
3. TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS, AND AS CLOSE TO
PROPERTY LINES AS IS PRACTICABLE.
4. MOUNTABLE CURB AND GUTTER TO BE USED IN RESIDENTIAL DEVELOPMENTS WHERE DRIVEWAYS ARE PRESENT.
5. STRAIGHT FACE CURB AND GUTTER TO BE USED FOR COMMERCIAL DEVELOPMENTS.
0.5
1.5 2.5
4.511.0
2.51.5
2.5
6.5
22.0
150mm PARABOLIC CROWN
WATER
MAIN
PRIMARY
POWER
CABLE TV
TELEPHONE
GAS
SANITARY
SEWER
SHALLOW
STORM
POWER
CABLE TV
TELEPHONE
1.0
2.0
1.25
3.0
P
L L
P
F.O
.C
.
F.O
.C
.
LIGHT
STANDARD
HYDRANT
2.03.25
5.0
1.0
GAS
STORM
SEWER
2.0
1.5
SEPARATE WALK (2% CROSSFALL)
TYPICAL SECTION
SHALLOW
STORM
50mm TYPE ACO ASPHALT SURFACE COURSE
125mm TYPE ACB ASPHALT BASE COURSE
300mm GRANULAR BASE COURSE
150mm MINIMUM PREPARED SUBGRADE
MINIMUM ROAD STRUCTURE
100mm WICK DRAIN, TIED TO CATCH BASIN
CURB & GUTTER
BACKFILL
300mm
R.O.W.
2-4m UTILITY
R.O.W.
2-4m UTILITY
CURB & GUTTER
BO
ULE
VA
RD
3%
SLO
PE
SEPERATE WALK
(2% CROSSFALL)
BO
ULE
VA
RD
3%
SLO
PE
-
0.5 1.5 2.5
4.5 12.0
2.5 1.5 2.5
6.5
23.0
170mm PARABOLIC CROWN
WATER
MAIN
PRIMARY
POWER
CABLE TV
TELEPHONE
GAS
SHALLOW
STORM
SANITARY
SEWER
POWER
CABLE TV
TELEPHONE
1.0
2.0
1.25
3.0
F.O
.C
.
F.O
.C
.
LIGHT
STANDARD
HYDRANT
2.0
3.25
5.0
1.0
GAS
STORM
SEWER
2.0
1.5
TYPICAL SECTION
50mm TYPE ACO ASPHALT SURFACE COURSE
125mm TYPE ACB ASPHALT BASE COURSE
300mm GRANULAR BASE COURSE
150mm MINIMUM PREPARED SUBGRADE
MINIMUM ROAD STRUCTURE
SHALLOW
STORM
100mm WICK DRAIN, TIED TO CATCH BASIN
CURB & GUTTER
BACKFILL
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
23/04/2014
25/02/2015
300mm
BO
ULE
VA
RD
3%
SLO
PE
R.O.W.
2-4m UTILITY
R.O.W.
2-4m UTILITY
BO
ULE
VA
RD
3%
SLO
PE
SEPARATE WALK (2% CROSSFALL)
CURB & GUTTER
SEPERATE WALK
(2% CROSSFALL)
NOTES:
1. ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.
2. ALL ROAD STRUCTURES ARE SUBJECT TO THE RECOMMENDATIONS IN THE GEOTCHNICAL REPORT AND THE FIELD
CONDITIONS AT THE TIME OF CONSTRUCTIONS.
3. TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS, AND AS CLOSE TO
PROPERTY LINES AS IS PRACTICABLE.
4. MOUNTABLE CURB AND GUTTER TO BE USED IN RESIDENTIAL DEVELOPMENTS WHERE DRIVEWAYS ARE PRESENT.
5. STRAIGHT FACE CURB AND GUTTER TO BE USED FOR COMMERCIAL DEVELOPMENTS.
-
180mm PARABOLIC CROWN
15.0 2.0
37.0
2.01.0 1.56.5
POWER CABLE
7.25
4
:
1
3
:
1
0.50.5
1.5
1.0
7.25
6.51.5
1.5
POWER CABLE
4
:
1
3
:
1
SEPARATE WALK (2% CROSSFALL)
0.5 0.5
ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.2.
TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS,1.
NOTES:
AND AS CLOSE TO PROPERTY LINES AS IS PRACTICABLE.
TYPICAL SECTION
300mm GRANULAR BASE COURSE
50mm TYPE ACO ASPHALT SURFACE COURSE
150mm TYPE ACB ASPHALT BASE COURSE
BACKFILL
MINIMUM ROAD STRUCTURE
SCALE 1:10
HYDRANT IF REQUIRED
HYDRANT IF REQUIRED
BERM REQUIRED WHEN RESIDENTIAL BACKS ONTO ARTERIAL
CURB & GUTTER
150mm MINIMUM PREPARED SUBGRADE
100mm WICK DRAIN, TIED TO CATCH BASIN
CURB & GUTTER
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
300mm
BOULEVARD
3% SLOPE
SEPERATE WALK
(2% CROSSFALL)
5.0m
EASEMENT
5.0m
EASEMENT
-
8.0
2.0
45.0
2.01.0
1.5
7.75
POWER CABLE
8.5
4
:
1
3
:
1
1.00.5
1.5
1.0
8.5
7.75
1.5
0.501.0
1.5
PL L
P
SEPARATE WALK
POWER CABLE
4
:
1
3
:
1
4.58.0
SEPARATE WALK
2.5%
2.5%
7.75
2% CROSSFALL2% CROSSFALL
TOWARDS ROAD
TOWARDS ROAD
C
L
ALL DIMENSIONS IN METRES, UNLESS OTHERWISE NOTED.3.
TRANSFORMERS AND SWITCHBOXES MUST BE LOCATED OUTSIDE OF SIGHT LINES AT INTERSECTIONS,1.
NOTES:
AND AS CLOSE TO PROPERTY LINES AS IS PRACTICABLE.
TYPICAL SECTION
HYDRANT
BERM REQUIRED WHEN RESIDENTIAL BACKS ONTO ARTERIAL
MINIMUM ROAD STRUCTURE
CURB & GUTTER
CURB
& GUTTER
300mm GRANULAR BASE GRANULAR
50mm TYPE ACO ASPHALT SURFACE COURSE
ALL UNDERGROUND UTILITY ALIGNMENT TO BE APPROVED UNDER SEPARATE APPLICATION.2.
150mm TYPE ACB ASPHALT BASE COURSE
150mm MINIMUM PREPARED SUBGRADE
100mm WICK DRAIN, TIED TO CATCH BASIN
BACKFILL
CURB & GUTTER
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
300mm
5.0m
EASEMENT
BOULEVARD
3% SLOPE
BOULEVARD
3% SLOPE
5.0m
EASEMENT
-
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
PR
OP
ER
TY L
INE
FAC
E O
F C
UR
B
PARARAMP LOCATED AT APPROXIMATEMID-POINT OF RETURN RADIUS (NOT TOCONFLICT WITH DRIVEWAY LOCATION)
MOUNTABLE CURB & GUTTER
20.0
9.0
ALL DIMENSIONS IN METRES.NOTES:1.
6.54.5
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
R15.0(TYP.)
R12.0
-
ALL DIMENSIONS IN METRES.SIDEWALK TO END AT PROPERTY LINE PRIOR TO CURB RETURN.
2.
NOTES:1.
PR
OP
ER
TY L
INE
FAC
E O
F C
UR
B
T-BOLLARDS LOCATED AT BACK OFEASEMENT WHEN PUL PRESENT
WALKWAY OR TRAIL
PARARAMP LOCATED AT APPROXIMATEMID-POINT OF RETURN RADIUS (NOT TOCONFLICT WITH DRIVEWAY LOCATION)
MOUNTABLE CURB & GUTTER
20.0
9.0
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
MONOLITHIC SIDEWALK
R15.0(TYP)
R12.0
-
CURB
SIDEWALK
UNIFORM FENCE
PLPL
FENCE
VARIES 6.0m
CURB
EA
SE
ME
NT
0.150 mP TO FENCE
SIDEWALK
UNIFORM
L
EA
SE
ME
NT
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
VARIES
1.5mSIDEWALK
0.150 mP TO FENCEL
3.0m WALKWAYOR
-
2.5% MAX
2% CROSSFALL
1% MIN 2%
2%
2%
2.5% MAX
1% MIN
2%
PL PL
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
VARIES VARIES0.5m 3.0m WALKWAY
OR1.5m WALKWAY
0.5mVARIES VARIES
VARIES
-
SECTION A-A
MOUNTABLE CURB
MIN. 75mm OF COMPACTED GRANULAR FILL
75
125
EXPANSION BOARD
EXPANSION BOARD
EXPANSION BOARD
MIN. 2%
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
24/04/2014
15/04/2015
DWELLING
GARAGE WIDTH
SIDEWALK
CITY PROPERTY
A
A
600
MIN 3000 TO 7500 MAX
600
MIN 4200 TO 8700 MAX
1
1
TAPERED PORTION
ON CITY PROPERTY
OR 1:1
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.
2. SIDEWALK CROSSFALL MIN. 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.
3. NO DOWELING TO CURB OR SIDEWALK.
4. MAINTAIN MINIMUM CLEARANCE OF 1.25m FROM DRIVEWAY EDGE TO EDGE OF NEAREST STREET FURNITURE.
5. MAINTAIN MINIMUM CLEARANCE OF 1.5m FROM DRIVEWAY EDGE TO EDGE OF NEAREST TREE.
6. CALL CITY ENGINEERING SERVICES TO INSPECT APRON FORMS BEFORE CONCRETE POUR.
7. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
8. THE WIDTH OF TAPERED APRON ARE NOT TO EXTEND BEYOND THE PROJECTION OF SIDE PROPERTY AT CURB.
9. DRIVEWAYS CANNOT EXTEND INTO THE CUT CORNER OR CURB RETURN (BC/EC).
10. APRON MATERIAL MUST BE A POURED IN PLACE CONCRETE.
11. ASPHALT, PAVING STONES OR OTHER NON-POURED IN PLACE CONCRETE PRODUCTS WILL NOT BE PERMITTED FOR CITY APRONS.
12. THE CITY RESERVES THE RIGHT TO REPLACE APRONS AND DRIVEWAYS THAT FALL UPON CITY PROPERTY WITH STANDARD CONCRETE IF
INFRASTRUCTURE REPAIRS ARE REQUIRED.
MAXIMUM DRIVEWAY
WIDTH AT BACK OF
SIDEWALK IS THE
GARAGE WIDTH
OR 7.5m
WHICHEVER IS LESS
MINIMUM 1.35m
AT PROPERTY LINE
IT IS NOT ACCEPTABLE TO
EXTEND THE WALKWAY
PORTION OF THE DRIVEWAY
DIRECTLY TO THE BACK OF
THE SIDEWALK IF IT EXCEEDS
THE MAXIMUM DRIVEWAY
WIDTH.
PRIVATE PROPERTY
OPTIONAL
DRIVEWAY
EXPANSION
ON PRIVATE
PROPERTY
DRIVEWAY
APRON
-
SECTION A-A
MOUNTABLE CURB
MIN. 75mm OF COMPACTED GRANULAR FILL
75
125
EXPANSION BOARD
EXPANSION BOARD
EXPANSION BOARD
MIN. 2%
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
24/04/2014
15/04/2015
DWELLING
GARAGE WIDTH
MAXIMUM DRIVEWAY
WIDTH AT BACK OF
SIDEWALK IS
GARAGE WIDTH
OR 7.5m
WHICHEVER IS LESS
SIDEWALK
APRON
A
A
600
MIN 3000 TO 7500 MAX
600
MIN 4200 TO 8700 MAX
1
1
TAPERED PORTION
ON CITY PROPERTY
OR 1:1
CITY PROPERTY
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.
2. SIDEWALK CROSSFALL MIN. 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.
3. NO DOWELING TO CURB OR SIDEWALK.
4. MAINTAIN MINIMUM CLEARANCE OF 1.25m FROM DRIVEWAY EDGE TO EDGE OF NEAREST STREET FURNITURE.
5. MAINTAIN MINIMUM CLEARANCE OF 1.5m FROM DRIVEWAY EDGE TO EDGE OF NEAREST TREE.
6. CALL CITY ENGINEERING SERVICES TO INSPECT APRON FORMS BEFORE CONCRETE POUR.
7. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
8. THE WIDTH OF TAPERED APRON ARE NOT TO EXTEND BEYOND THE PROJECTION OF SIDE PROPERTY AT CURB.
9. DRIVEWAYS CANNOT EXTEND INTO THE CUT CORNER OR CURB RETURN (BC/EC).
10. APRON MATERIAL MUST BE A POURED IN PLACE CONCRETE.
11. ASPHALT, PAVING STONES OR OTHER NON-POURED IN PLACE CONCRETE PRODUCTS WILL NOT BE PERMITTED FOR CITY APRONS.
12. THE CITY RESERVES THE RIGHT TO REPLACE APRONS AND DRIVEWAYS THAT FALL UPON CITY PROPERTY WITH STANDARD CONCRETE IF
INFRASTRUCTURE REPAIRS ARE REQUIRED.
MINIMUM 1.35m
AT PROPERTY LINE
IT IS NOT ACCEPTABLE TO
EXTEND THE WALKWAY
PORTION OF THE DRIVEWAY
DIRECTLY TO THE BACK OF
THE SIDEWALK IF IT EXCEEDS
THE MAXIMUM DRIVEWAY
WIDTH.
PRIVATE PROPERTY
OPTIONAL
DRIVEWAY
EXPANSION
ON PRIVATE
PROPERTY
OPTIONAL
DRIVEWAY
EXPANSION
ON PRIVATE
PROPERTY
DRIVEWAY
-
SECTION A-A
MOUNTABLE CURB
MIN. 75mm COMPACTED GRANULAR FILL
75
125
EXPANSION BOARD
EXPANSION BOARD
EXPANSION BOARD
MIN. 2%
A
A
DWELLING DWELLING
MIN. GAP 2.5m
1.25m 1.25m
600
Min 3000 to 5500 Max
600
600
600
Min 4200 to 6700 Max
Min 3000 to 5500 Max
Min 4200 to 6700 Max
DRIVEWAY DRIVEWAY
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
24/04/2014
15/04/2015
GARAGE WIDTH GARAGE WIDTH
MAXIMUM DRIVEWAY
WIDTH AT BACK OF
SIDEWALK IS
GARAGE WIDTH
OR 5.5m
WHICHEVER IS LESS
APRON APRON
SIDEWALK
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.
2. SIDEWALK CROSSFALL MIN. 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.
3. NO DOWELING TO CURB OR SIDEWALK.
4. MAINTAIN MINIMUM CLEARANCE OF 1.25m FROM DRIVEWAY EDGE TO EDGE OF NEAREST STREET FURNITURE.
5. MAINTAIN MINIMUM CLEARANCE OF 1.5m FROM DRIVEWAY EDGE TO EDGE OF NEAREST TREE.
6. CALL CITY ENGINEERING SERVICES TO INSPECT APRON FORMS BEFORE CONCRETE POUR.
7. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
8. THE WIDTH OF TAPERED APRON ARE NOT TO EXTEND BEYOND THE PROJECTION OF SIDE PROPERTY AT CURB.
9. DRIVEWAYS CANNOT EXTEND INTO THE CUT CORNER OR CURB RETURN (BC/EC).
10. APRON MATERIAL MUST BE A POURED IN PLACE CONCRETE.
11. ASPHALT, PAVING STONES OR OTHER NON-POURED IN PLACE CONCRETE PRODUCTS WILL NOT BE PERMITTED FOR CITY APRONS.
12. THE CITY RESERVES THE RIGHT TO REPLACE APRONS AND DRIVEWAYS THAT FALL UPON CITY PROPERTY WITH STANDARD CONCRETE IF
INFRASTRUCTURE REPAIRS ARE REQUIRED.
MIN. GAP 2.5m
HYDRANT
M
I
N
.
1
.
2
5
m
M
I
N
.1
.
2
5
m
MAXIMUM DRIVEWAY
WIDTH AT BACK OF
SIDEWALK IS
GARAGE WIDTH
OR 5.5m
WHICHEVER IS LESS
LOT WIDTH LESS THAN 12.2mLOT WIDTH LESS THAN 12.2m
-
PLAN
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
13/08/2013
13/05/2015
A
A
SECTION A-A
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%
2. TYPICAL BOULEVARD CROSSFALL IS 3% FROM TOC ELEVATION UP TO THE PROPERTY LINE ELEVATION UNLESS OTHERWISE NOTED.
3. COMMERCIAL CROSSING SHALL BE MIN. 180mm IN THICKNESS REINFORCED WITH 100 X 200 No. 6 STEEL WELDED WIRE MESH OR MIN.
10M REBAR SPACED @ 300mm O.C. IN BOTH DIRECTIONS.
4. EXISTING ROADWAY CURB AND GUTTER TO BE REMOVED & REPLACED WITH TAPER DROP CURB SECTIONS.
5. MAINTAIN MIN 1.5m CLEARANCE TO NEAREST STREET FURNITURE, FIRE HYDRANT, AND TREES.
6. COMMERCIAL CROSSING TO BE COMPLETED IN 2 POURS. FORM AND POUR THE CURB & GUTTER. INSTALL DOWELS AT THE
CONNECTIONS TO EXISTING CONCRETE CURBS. INSTALL EXPANSION BOARD BETWEEN THE CURB & GUTTER AND THE CONCRETE
APRON. POUR THE CONCRETE APRON. INSTALL EXPANSION BOARD AT THE CONNECTION TO THE EXISTING SIDEWALK (IF PRESENT).
7. COMMERCIAL CROSSING TO BE CONSTRUCTED USING CONCRETE FROM CURB LINE TO PROPERTY LINE AND ACCOMMODATE ANY
EXISTING SIDEWALK (IF PRESENT) WITH EXPANSION BOARDS.
8. MINIMUM 3.0m x 3.0m SQUARE JOINTS SAWCUT INTO CONCRETE.
-
P
L
PLAN
A
A
SAWCUT
EXISTING
CURB
PROVIDE
3 x 10M
REBAR
DOWELS
SAWCUT
EXISTING
CURB
PROVIDE
3 x 10M
REBAR
DOWELS
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
150mm
150mm
9.0m MIN
CO
NC
RE
TE
AP
RO
N
CURB TO MATCH EXISTING
P
L
1.5m SIDEWALK
150mm COMPACTED GRANULAR FILL
D
R
A
IN
A
G
E
P
L
SECTION A-A
DRAINAGE
WIDTH TO
MATCH AND MIRROR
EXISTING GUTTER
PAN
200
TYP.
25
TYP.
EXPANSION BOARD
6
0
1
8
0
1
5
0
CONCRETE OR
ASPHALT PAVEMENT
FOC = FACE OF CURB
BOC = BACK OF CURB
TOC = TOP OF CURB
LOG = LIP OF GUTTER
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.
2. TYPICAL BOULEVARD CROSSFALL IS 3% FROM TOC ELEVATION UP TO THE PROPERTY LINE ELEVATION UNLESS OTHERWISE NOTED.
3. COMMERCIAL CROSSING SHALL BE MIN. 180mm IN THICKNESS REINFORCED WITH 100 X 200 No. 6 STEEL WELDED WIRE MESH OR MIN.
10M REBAR SPACED @ 300mm O.C. IN BOTH DIRECTIONS.
4. EXISTING ROADWAY CURB & GUTTER TO BE REMOVED & REPLACED WITH MIRRORED CONCRETE GUTTER.
5. EXISTING ROADWAY CURB & GUTTER TO CONNECT TO CONCRETE APRON AS SHOWN.
6. MAINTAIN MIN 1.5m CLEARANCE TO NEAREST STREET FURNITURE, FIRE HYDRANT, AND TREES.
7. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.
8. COMMERCIAL CROSSING TO BE COMPLETED IN 2 POURS. FORM AND POUR THE CURB AND GUTTER. INSTALL DOWELS AT THE
CONNECTIONS TO EXISTING CONCRETE CURBS. INSTALL EXPANSION BOARDS. POUR THE CONCRETE APRON.
9. COMMERCIAL CROSSING TO BE CONSTRUCTED USING CONCRETE FROM ROADWAY TO PROPERTY LINE.
10. IF PRESENT, EXISTING SIDEWALK BETWEEN THE PEDESTRIAN RAMPS INSIDE THE CONCRETE APRON TO BE SAW CUT AND REMOVED.
11. MINIMUM 3.0m x 3.0m SQUARE JOINTS SAWCUT INTO CONCRETE.
5
.
0
m
R
5
.
0
m
R
BOC
FOC
SAWCUT AND REMOVE EXISTING SIDEWALK
1
5
0
150mm PREPARED SUBGRADE - 100% SPD
13/08/2013
STRAIGHT FACE CURB AND GUTTER
LOG
EXPANSION BOARD
13/05/2015
SQUARE OFF TRANSITION
MIN. 500mm WIDTH
-
30003000
7300
6.0m LANE
CL
1500
VARIES
LP
75 SAG (ROLLED F.C.)100 SAG (VERT F.C.)
DETAIL A
450
140 OR 200
40R=150
R=150
PL
DETAIL A
25
DROP CURB
50
150 x 150 STEEL MESH REINFORCING
50mm COMPACTED GRANULAR FILL
1:40SECTION A-A
50
NOTES:1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%2. SIDEWALK CROSSFALL TO 2% TOWARDS THE ROAD UNLESS OTHERWISE AUTHORIZED.3. LANE APRONS SHALL BE MINIMUM 150mm THICK WITH 150 x 150 NO. 6 STEEL MESH REINFORCEMENT CAN SUBSTITUTE
#10M OR BETTER REBAR @ 12" OC BOTH DIRECTIONS.4. EXISTING STANDARD CURB & GUTTER TO BE REMOVED AND REPLACED WITH TAPER AND DROP CURB SECTIONS.5. MAINTAIN MIN 1.5m CLEARANCE TO NEAREST STREET FURNITURE, FIRE HYDRANT, AND TREES.6. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED.
150
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
EXPANSION BOARD
-
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. ALL DIMENSIONS IN MILLIMETERS.2. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%3. CONCRETE REINFORCED WITH #10M OR BETTER REBAR PLACED AT 100mm DEEP AND 300mm EACH WAY.4. 50 mm DEEP TRANSVERSE SAWCUTS TO BE MADE AT 3.0mm C-C AND CAULKED WITH AN APPROVED SEALANT ALONG
LIP OF GUTTER. (OR CONTRACTION JOINT DURING INSTALLATION.)
EXPANSION BOARD
2% 100
150
1253%
EXPANSION BOARD
250 150150 STANDARD REVERSE CURB & GUTTER
1500SIDEWALK3500
ROADWAY
200mm PREPARED SUBGRADE
200mm CONCRETE 30MPa
BUS BAY
A
SIDEWALK
A
PLAN
SECTION A-A
MATCH AND MIRROR EXISTING GUTTER
GUTTERCURB
-
10M BAR
2.2m
125
2.0% X-FALL
STANDARD MONOWALK
SECTION A-ASCALE: NTS
EXPANSION BOARD
5050mm COMPACTEDGRANULAR FILL TO
98% S.P.D.
CURB & GUTTER
2.2m
3.5m
A
A
BUS PAD(USE FOR BUS SHELTER
IF REQUIRED)
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR
ENTRAINMENT 5% TO 7%2. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.
-
125
2.0% X-FALL
1.5m
SECTION A-A
SCALE: NTS
2.5m
STOP AND SHELTER PAD
SIDEWALK
50
75
GRANULAR SUBGRADE
COMPACTED TO 98% S.P.D.
10M REBAR
EXPANSION BOARDS
CURB
A
A
2.5m
5.0m
BUS STOP PAD
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%.
2. CONTRACTION JOINTS ARE TO BE PROVIDED AT A MINIMUM 3.0m SPACING.
3. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.
4. THE DEVELOPER IS RESPONSIBLE TO INSTALL BUS SHELTERS UPON ARTERIAL ROADS.
5. THE DEVELOPER IS RESPONSIBLE TO INSTALL BUS SHELTERS UPON COLLECTOR ROADS ADJACENT TO MULTI-FAMILY SITES.
6. CITY OF ST. ALBERT BRANDING STAMP TO BE PLACED IN THE CORNER AT THE BUS STOP PAD (AS SHOWN). THE EDGE OF THE
STAMP IS TO BE LOCATED 80mm FROM THE EDGE AT THE BUS STOP PAD AND 80mm FROM THE BOC. APPLY A RELEASING
AGENT TO THE SURFACE OF THE CONCRETE WHEN APPLYING THE BRANDING STAMP.
7. BUS STOP BENCH MUST BE ANCHORED TO THE CONCRETE PAD.
8. THE FRONT EDGE OF BUS STOP BENCH MUST BE SET BACK A MINIMUM 1.5m FROM THE FACE OF CURB AND ANGLED TO FACE
DIRECTION OF TRAVEL. THE REAR EDGE OF THE BUS STOP BENCH MUST NOT EXTEND ONTO THE SIDEWALK.
9. THE FRONT EDGE OF THE BUS STOP SHELTER MUST BE SET BACK A MINIMUM OF 1.0m FROM THE FACE OF CURB. THE REAR
EDGE OF THE BUS STOP SHELTER (INCLUDING ANCHOR PLATE) MUST NOT EXTEND ONTO THE SIDEWALK.
10. THE OPENING OF THE BUS STOP SHELTER MUST DIRECT USERS TO THE SIDEWALK.
11. ADVERTISEMENTS UPON BUS STOP BENCHES AND SHELTERS ARE NOT PERMITTED WITHOUT WRITTEN CONSENT FROM THE
CITY OF ST. ALBERT TRANSIT DEPARTMENT.
01/10/2013
VEHICLE DIRECTION OF TRAVEL
FOC
BOC
0.5m - 2.5m
80
B
E
N
C
H
9.0m
BUS SHELTER PAD
4.0m
80
BUS STOP
SIGN POST
50-150
750
12/03/2015
SHELTER
3.0% X-FALL
-
125
2.0% X-FALL
1.5m
SECTION A-ASCALE: NTS
2.5mBUS PAD
SIDEWALK
5050mm
COMPACTED GRANULARFILL AT 98% S.P.D. 10M BAR
(TYP.)
EXPANSION BOARDS
CURB & GUTTER
A
A
2.5m 5.0m
BUS STOP PAD
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. 30MPa CONCRETE IN 28 DAYS, SLUMP 75 MAX, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%2. UNITS IN MILLIMETERS UNLESS OTHERWISE INDICATED.3. CITY OF ST. ALBERT BRANDING STAMP TO BE PLACED IN THE CORNER AT THE BUS STOP PAD (AS SHOWN). THE EDGE OF THE STAMP IS
TO BE LOCATED 80mm FROM THE EDGE AT THE BUS STOP PAD AND 80mm FROM THE BOC. APPLY A RELEASING AGENT TO THESURFACE OF THE CONCRETE WHEN APPLYING THE BRANDING STAMP.
01/10/2013
VEHICLE DIRECTION OF TRAVEL
FOC
BOC
80mm80mm
BENC
H
-
1 3/4" (44.45mm)
900m
m
WASHER NYLOC STYLE
LOCKING NUT
SIGN BOARD
NOTE:
ALL FASTENING HARDWARE
MUST HAVE NON-CORROSIVE
COATING
SIGN BOARD FASTENING DETAIL
SIDEWALK OR PATH
1.0m
min 2.0m
1.0m
SIDEWALK
X
ACTUAL INCH & MILLIMETER SIZES
1.75"
2.00"
2.25"
2.50"
WALL
0.105"
44.45mm
50.80mm
57.15mm
63.50mm
2.667mm
1.875" 47.50mm
3/8" GALVANIZED STEEL
CONCRETE
2" OM, 1 3/4" IM GALVANIZED STEEL
APPROVED POSTS AND HARDWARE:
GROUND & CONCRETE MOUNT:
- TELESPAR.
- SQUARE FIT.
- EACH SIGN INSTALLATION REQUIRES
A POST, BASE, AND BASE SLEEVE.
1/2 X or 1.0m FROM FACE OF
CURB, WHICH EVER IS LESS
CONCRETE
POST INSTALLATION DETAIL
GROUND
POST INSTALLATION DETAIL
EXISTING GROUND
1 3/4" GALVANIZED STEEL
TELESPAR POST
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
max 3.0m
min 2.0m
max 3.0m
min 2.0m
max 3.0m
10" (254mm)
TELESPAR. WITH 7/16" HOLES EVERY
INCH ON THE FULL LENGTH ON ALL
4 SIDES OF THE SQUARE POST
SQUARE BASE PLATE
8" (203.2mm)
7" (177.8mm)
3/8" (9.53mm)
5/8" (15.88mm)
NOTES:
1) WHERE AVAILABLE, MOUNT SIGNS TO EXISTING STREET POLES.
2) OTHER THAN PARKING/STOPPING RESTRICTION SIGNS, MOUNT SIGNS
PERPENDICULAR TO THE ROADWAY.
3) DO NOT INSTALL POSTS WITH BREAKAWAY DEVICES UNLESS DIRECTED
BY THE CITY.
4) STEEL BANDING IS TO BE USED TO SUPPORT THE BRACKET AND HOLD
THE SIGN THAT IS TO BE MOUNTED.
5) USE "U'" SHAPED BRACKETS (PART UB021).
-
150mm x 150mm DARK COLORED RECYCLED PLASTIC BOLLARD
1.0
CONCRETEBACKFILLED WITH
AUGER HOLE 1.0
75 m
m 75m
m
GROUND LINE
BOLLARDS LAYOUT FOR END OF THE ROAD STRUCTURE
SID
EW
ALK
SID
EW
ALK
PR
OP
ER
TY L
INE
PR
OP
ER
TY L
INE
WA-8
2400
WA-8
75mm WIDE RED REFLECTIVE TAPE
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
15/01/14DD/MM/YY
2.02.5 2.0 2.0 2.5 2.52.52.5 2.0
4.5 9.0 6.5
NOTES:1. ALL UNITS IN METRES UNLESS NOTED OTHERWISE.2. BOLLARD SPACING MEASURED ON CENTRE OF BOLLARDS.3. A BOLLARD AND THE WARNING SIGN ARE TO BE PLACED AT THE CENTER LINE OF THE ROADWAY.4. BOLLARDS ARE TO BE SET PLUMB.5. THE TOP OF BOLLARD ELEVATION SHOULD BE CONSISTENT ALONG A SET OF BOLLARDS.
CL
TOP OF BOLLARD ELEVATION
-
NOTES1. ALL UNITS IN METRES UNLESS OTHERWISE NOTED.2. POSITION BOLLARDS MINIMUM 1.0m BEHIND UTILITY EASEMENT.3. CAN BE USED WITH 1.5m WALK OR NO SIDEWALK4. MAXIMUM WIDTH OF PUBLIC WORKS MAINTENANCE EQUIPMENT IS 73".5. BOLLARDS ARE TO BE SET PLUMB.6. THE TOP OF BOLLARD ELEVATION SHOULD MATCH ONE ANOTHER.
1.751.75
2.252.25
6.0m P.U.L.
PR
OP
ER
TY L
INE
PR
OP
ER
TY L
INE
1.0
2-4m (TYP.)UTILITY
EASEMENT
PLAN
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
08/04/2014
1.0
CONCRETEBACKFILLED WITH
AUGER HOLE 1.0
75m
m 75m
m
GROUND LINE
75mm WIDEWHITE REFLECTIVETAPE
150mm x 150mm DARK COLOREDRECYCLED PLASTIC BOLLARD
DETAIL
SIDEWALK
1.5mCONCRETE WALK
TOP OF BOLLARD ELEVATION
2.5
GAP2.35
(92.5")
-
STYLE OF LINE DIMENSION (m) NAME/USE/COLOR
SOLID
BROKEN
DENSEBROKEN
WIDESOLID
WIDEBROKEN
DOUBLESOLID
SIMULTANEOUSSOLID AND
BROKEN
DOUBLEBROKEN
10cm
10cm 6m
3m
10cm 0.5m
0.05m
20cm
20cm 3.0m
3.0m
10cm
10cm
10cm
10cm 3m 6m 3m
10cm10cm
10cm 3m 6m 3m
-EDGE LINES (WHITE OR YELLOW)-DIRECTIONAL DIVIDING LINES (YELLOW)-LANE LINES PROHIBITING LANE CHANGES (WHITE)
-LANE LINES (WHITE)
-GUIDE LINES (eg. INTERSECTION MOVEMENTS) YELLOW OR WHITE.
-EDGE LINES IN CRITICAL AREAS (WHITE ON THE RIGHT, YELLOW ON THE LEFT)-CONTINUITY LINES PROHIBITING LANE CHANGES (WHITE)
-CONTINUITY LINES IN MERGING AND DIVERGING AREAS-FORCED TURN LANE (LANE ENDING)
-DIRECTIONAL DIVIDING LINES (YELLOW)-LANE LINES WHERE LANE CHANGES FROM EITHER SIDE ARE PROHIBITED (WHITE)
-DIRECTIONAL DIVIDING LINES, TWO-WAY LEFT TURN LANES (YELLOW)-LANE LINES WHERE LANE CHANGES FROM ONE SIDE ARE PROHIBITED (WHITE)
-REVERSIBLE LANES (YELLOW)
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
10cm
-
SIDEWALK
FACE OF CURB
SIDEWALK
FACE OF CURB
MIN 0.65m FROM FOC
10cm WHITE CROSSWALKLINE10cm YELLOW CENTERLINE
MIN 1.0m
30cm WHITESTOP BAR LINE
NOTES:
1. INLAID TRANSVERSE MARKINGS ARE TO BE MINIMUM 8mm DEEP2. YELLOW CENTER LINE IS TO BE CARRIED TO THE BACK CROSSWALK LINE3. THE STOP BAR IS TO BE PLACED PERPENDICULAR TO THE ROADWAY -
MINIMUM DISTANCE TO THE CROSSWALK IS 1.0m
MIN.3.0m
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
30cm
60cmLIP OF GUTTER
CURBFACE
CENTRE OF ROAD
3m
1.80m 1.85m 1.85m 1.85m 1.85m 1.80m
5.50m 5.50m
11.0m
LIP OF GUTTER
CURBFACE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
60cm
30 cm
70cm
EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL EQUAL
CENTRE OF ROAD
SECONDARY LINE SECONDARY LINE
LIP OFGUTTER
CURBFACE
70cm
RIGHT TURN CUT-OFF
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
1.0 2.0
3.0
6.0
1.02.0
3.0
6.0
NOTES:1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE NOTED.2. ENTERING LANE LINES ARE 1.0m OFF OF ZEBRA BARS.3. ENTERING YELLOW CENTER LINE IS 1.0m OFF OF ZEBRA BARS.4. EXITING LANE LINES ARE 2.0m OFF OF ZEBRA BARS.5. EXITING YELLOW CENTER LINE IS 1.0m OFF OF ZEBRA BARS.
-
MIN 6m
30cm STOP LINE
NOTES:1. LENGTH OF STOP BOX TO BE DETERMINED BY TURNING TEMPLATES2. IF LANE LINES ARE 10cm WIDE, THEN THE LINE (RIGHT SIDE) OF THE PENALTY BOX SHALL BE
10cm FROM BACK STOP BAR TO CROSSWALK.3. IF IT IS A TURN LANE, THE LANE LINES SHALL BE 20cm WIDE AND THE LINE (RIGHT SIDE) OF
THE PENALTY BOX SHALL BE 20cm FROM BACK STOP BAR TO CROSSWALK.4. A 3.0m LANE LINE (20cm OR 10cm) SHALL RUN DIRECTLY OFF OF THE BACK STOP BAR.
THEREFORE, TOTAL DISTANCE OF SOLID LINE FROM CROSSWALK TO FIRST GAP OF LANELINES PRIOR TO THE PENALTY BOX IS A MINIMUM OF 9.0m.
30cm STOP LINE
YC
LY
CL
10cm CROSSWALK (MIN. 3.0m WIDE)10
cm O
R 2
0cm
LA
NE
LIN
E
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
10cm CONTINUITY LINE OR 20cm CONTINUITY LINE
10cm PENALTY BOX
-
5.5m min
3.0m
1.0m min
GORE STOPS AT CROSSWALK
3.0m
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. LANE LINES STOP AT STOP BARS.2. CROSSWALK LINES RUN TO THE CURB.
-
MINORCOLLECTOR
30m MIN
MAJORCOLLECTOR
ARTERIAL
ARTERIAL
30m MIN
LANE LINE - LEAD-INON MAJOR COLLECTOR
DIRECTIONAL DIVIDING LINELEAD-IN ON MINOR COLLECTOR
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
YY
Y
4
1
1
1
11
2
3
3
3
3
3
3
Y
16.0
4.65
6.0
FULL
Y S
IGN
ALI
ZED
INTE
RS
EC
TIO
N
MID
-BLO
CK
PE
DE
STR
IAN
CR
OS
SIN
G
PE
DE
STR
IAN
AC
TIV
ATE
D S
IGN
ALI
ZED
INTE
RS
EC
TIO
N
3
2
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
1.0
2.0
3.0
6.0
1.0
2.0
3.06.0
NO
TES
:1.
ALL
DIM
EN
SIO
NS
AR
E IN
ME
TRE
S U
NLE
SS
OTH
ER
WIS
E N
OTE
D.
2.E
NTE
RIN
G L
AN
E L
INE
S A
RE
1.0
m O
FF O
F ZE
BR
A B
AR
S.
3.E
NTE
RIN
G Y
ELL
OW
CE
NTE
R L
INE
IS 1
.0m
OFF
OF
ZEB
RA
BA
RS
.4.
EX
ITIN
G L
AN
E L
INE
S A
RE
2.0
m O
FF O
F ZE
BR
A B
AR
S.
5.E
XIT
ING
YE
LLO
W C
EN
TER
LIN
E IS
1.0
m O
FF O
F ZE
BR
A B
AR
S.
-
SIGNAL POLE
MIN. 3.0m
16.0m
4.65m MIN
CROSSWALK
STOP BAR
STOP BAR
16.0m
16.0m
STOP BAR
STOP BAR
STOP BAR
STOP BAR
4.65m MIN
16.0m
NOTES:1. LANE LINES RUN UP UNTIL THE STOP BAR
AND EXIT OUT OF THE CROSSWALK.2. CENTER LINE RUNS UP TO THE FRONT
CROSSWALK.
SCENARIO 1:
SCENARIO 2:
SCENARIO 3:
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
SIGNAL POLE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
10cm YELLOW GUIDE LINELINE/GAP RATIO 0.5:0.5 20cm WHITE CONTINUITY LINE
LINE/GAP RATIO 3:3
10cm WHITE GUIDE LINELINE/GAP RATIO 0.5:0.5
20cm WHITE CONTINUITY LINELINE/GAP RATIO 3:3
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
5.5m
5.5m
5.5m
20cm WHITECONTINUITY LINE 3:3 CONTINUITY LINE
NOT REQUIRED
20cm WHITECONTINUITY LINE3:3
20cm WHITECONTINUITY LINE 3:3
20cm WHITECONTINUITY LINE
3:3
CONTINUITY LINENOT REQUIRED
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
10cm WHITE GORE LINE
-
10cm WHITE LANE LINE 3:6 60m
30m
10cm WHITE LANE LINE 3:6
80m 30m
10cm WHITE LANE LINE 3:6
20cm WHITE BROKEN LINE 3:3
80m 30m
SPEED LIMITS OF 60 km/h OR LESS
SPEED LIMITS OF 70 km/h TO 90 km/h
SPEED LIMITS OF 100 km/h OR GREATER
120m
260m
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
CENTERLINE OF ROAD
CENTERLINE OF ROAD
CENTERLINE OF ROAD
20cm WHITE BROKEN LINE 3:3
20cm WHITE BROKEN LINE 3:3
CURB FACE
CURB FACE
CURB FACE
-
10cm WHITE LANE LINE 3:6
20cm WHITE BROKEN LINE 3:3
60m
30m
20 cm WHITE BROKEN LINE 3:3
80 m 30 m
10 cm WHITE LANE LINE 3:6
20 cm WHITE BROKEN LINE 3:3
80 m 30 m
SPEED LIMITS OF 60 km/h OR LESS
SPEED LIMITS OF 70 km/h TO 90 km/h
SPEED LIMITS OF 100 km/h OR GREATER
120 m
260 m
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
CENTERLINE OF ROAD
CURB FACE
10cm WHITE LANE LINE 3:6
CENTERLINE OF ROAD
CURB FACE
CENTERLINE OF ROAD
CURB FACE
-
20cm
WH
ITE
BR
OK
EN
LIN
E 3
:3
30m
80m
120m
AD
DIT
ION
AL
AR
RO
WS
SH
OU
LD B
EA
DD
ED
AT
120
m IN
TER
VA
LS T
O A
MA
XIM
UM
OF
4 A
RR
OW
S IN
TO
TAL
40m
20 c
m W
HIT
E B
RO
KE
N L
INE
3:3
LAN
E C
HA
NG
E A
RR
OW
RE
QU
IRE
D F
OR
FO
LLO
WIN
G
-LE
FT O
R R
IGH
T LA
NE
DR
OP
-ME
RG
E L
AN
E G
RE
ATE
R T
HA
N 2
00 m
-DO
UB
LE L
AN
E E
NTR
Y-U
NP
RO
TEC
TED
TU
RN
LA
NE
-WH
EN
A T
HR
OU
GH
LA
NE
BE
CO
ME
S A
TU
RN
LA
NE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
10cm WHITE EDGE LINE
10cm WHITE SOLID LINE
10cm WHITE EDGE LINE
10cm WHITE SOLID LANE LINESTARTING AT BEGINNING OFCURVE
CONTINUITY LINE LENGTHAND NUMBER OF ARROWS
TRAVELTIME(sec)
ROADWAYSPEED LIMIT
(km/h)
CONTINUITYLINE LENGTH
(m)
NUMBEROF
ARROWS
ARROWSPACING AT
(m)
448881212
5060708090100110
6060140140140260260
1122233
404040, 8040, 8040, 8040, 80, 12040, 80, 120
FOR SPEEDS ABOVE 100 km/h OR 110 km/h ADDITIONAL ARROWSMAY BE ADDED IF SPACE IS AVAILABLE AT 120m
20cm WHITE CONTINUITY LINE 3:3
10cm WHITE BROKEN LINE 3:6
40m
80m
120m
SEE TABLEFOR
CONTINUITYLINE LENGTH
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
CONTINUITY LINE LENGTHAND NUMBER OF ARROWS
TRAVELTIME(sec)
ROADWAYSPEED LIMIT
(km/h)
CONTINUITYLINE LENGTH
(m)
NUMBEROF
ARROWS
ARROWSPACING AT
(m)
448881212
5060708090100110
6060140140140260260
1122233
404040, 8040, 8040, 8040, 80, 12040, 80, 120
FOR SPEEDS ABOVE 100 km/h OR 110 km/h ADDITIONAL ARROWSMAY BE ADDED IF SPACE IS AVAILABLE AT 120m
SEE TABLEFOR
CONTINUITYLINE LENGTH
10 m
10m
10cm WHITE EDGE LINE
10cm YELLOW EDGE LINE
10cm WHITE EDGE LINE
20cm WHITE EDGE LINE
20cm WHITE LINE
10cm DOUBLE WHITE SOLID LANE LINEBEGINNING AT TAIL END OF FIRST SETOF ARROWS
10cm YELLOWEDGE LINE
20cm WHITEGORE LINE
40m
80m
120m
20cm WHITE CONTINUITY LINE 3:3
10cm WHITE LANE LINE 3:6
10cm WHITE EDGE LINE10cm WHITE BROKEN LINE 3:6
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
10 cm WHITE EDGE LINE
4 SECONDS OFTRAVEL TIME
AT SPEED LIMIT
10 cm WHITE EDGE LINE
4 SECONDS OFTRAVEL TIME
AT SPEED LIMIT 10 m
10 cm WHITE EDGE LINE
10 m10 m
10 m
END OF TAPER END OF TAPER
10 cm WHITE SEPARATION 3:6
10 cm YELLOW EDGE LINE
20 cm WHITE CONTINUITYLINE LINE/GAP RATIO 3:3
20 cm WHITE EDGE LINE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
TRANSITION POINT(TYP.)
10mSPACING
-
10m
1.25m
10cm SOLID EDGE LINE
DIVERGING GORE DETAIL
0.50m
MERGING GORE DETAIL
10cm SOLID EDGE LINE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
10 m
10 c
m W
HIT
E E
DG
E L
INE
EN
D O
F TA
PE
R
4 S
EC
ON
D O
F TR
AV
EL
TIM
E A
T S
PE
ED
LIM
IT
5.5
m
10 m
20 c
m W
HIT
E E
DG
E L
INE
10 c
m W
HIT
E E
DG
E L
INE
10 c
m W
HIT
E E
DG
E L
INE
ED
GE
LIN
E IF
RE
QU
IRE
D
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
TRA
NS
ITIO
N P
OIN
T
20 c
m W
HIT
E L
AN
E L
INE
S 3
:3
-
10cm
SO
LID
ED
GE
LIN
E
1.25m
10m
20cm
CO
NTI
NU
ITY
LIN
E 3
:3
10cm
BR
OK
EN
LIN
E 3
:6
10cm
YE
LLO
W C
L
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
10m10m
Y
Y
CE
NTR
E L
INE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
ED
GE
LIN
E IF
RQ
UIR
ED
10m
TO B
EG
INN
ING
OF
20 c
m E
DG
E L
INE
10m
GO
RE
AR
EA
10m
5.5m
20cm
CO
NTI
NU
ITY
LIN
E 3
:3
10cm
WH
ITE
ED
GE
LIN
E
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
DD/MM/YY Engineering Services
75cm 75cm
30cm
38cm
210c
m
30cm
76cm
300c
m
285c
m
225c
m60
cm
30cm
75cm
75cm
DD/MM/YY
DD/MM/YY
-
30cm
75cm 75cm
76cm
75cm
75cm
32cm38cm
210c
m120cm
30cm
30cm
328c
m
415c
m
30cm
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
30cm
114cm
30cm
128c
m
38cm
44cm
64cm
285c
m
395c
m
30cm
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
R10
5210
10
23
4.8
10
36
4°
37
27
15 7
38
10
822
2
2
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. ALL DIMENSIONS IN CENTIMETERS.
-
A
A
DETAIL #1
SLOPEDSURFACE
SLOPEDSURFACEMAXIMUM 6.0%
1.5 1.5MINIMUM
RAMPMINIMUM
RAMPSECTION A-A
100mm LINE
100mm LINE300mm LINE
0.6
1.0
2.5m MINIMUM (4.0m DESIRABLE)
DETAIL SHOWINGCROSSWALK DIMENSIONS
R=1.5
R=1.5 R=1.5
R=1.5
R=12R=12
R=3.0
R=60R=60
1.5m SIDEWALK1.5m SIDEWALK
1.5m SIDEWALK1.5m SIDEWALK
SEE DETAIL 2DETAIL #2
1:250
N.T.S.
1:500
TOP OF CURB
10cm X 3m WIDTH 10cm X 3m WIDTH WHITE THERMOPLASTIC
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. SIDEWALK RAMPS MUST PROVIDE ACCESS DIRECTLY TO
CROSSWALKS.2. THE SECTION OF CURB RAMP TYPE OS DEPENDANT ON THE
LOCATION OF THE CROSSWALK RELATIVE TO THE CURB FACE.WHERE THE CURB RETURN RADIUS IS GREATER THAN OREQUAL TO 4.0m, ONE TYPE 2 RAMP CAN BE USED. WHERE THECURB RETURN RADIUS IS LESS THAN 4.0m, TYPE 1 RAMPS AREREQUIRED.
3. WHERE CROSSWALKS ARE CONTROLLED BY SIGNALS WITH APUSH-BUTTON SYSTEM, THE SIDEWALKS AND RAMPS MUSTALLOW ACCESS BY WHEELCHAIR TO THE PUSH-BUTTON.
4. REFER TO DRAWINGS 4.6 & 4.7 FOR DETAIL OF TYPE 1 ANDTYPE 2 RAMPS.
5. ON A SHARP CORNER WHERE TWO TYPE 1 RAMPS ARE BEINGUSED, THE SLOPE ON THE FLARED AREAS CAN BE LESS THANTHE 8% MAX SLOPE SHOWN. THIS WILL PROVIDE A SMOOTHERSIDEWALK FOR GENERAL USE, ESPECIALLY FOR PEDESTRIANSWHO ARE NOT USING THE CROSSWALK.
6. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE NOTED.
FACE OFCURB
LIP OFGUTTER
3.5mLANES
SEEDETAIL 1
SIDEWALKSURFACE
SLOPEDSURFACE
MAXIMUM 6.0%
-
200
20025
300
75
100
ROD AT TIE-INS
75
100
150
25
300
EXTR
UD
ED
SEC
TIO
N
STANDARD BARRIER CURB
CURB CROSSING BARRIER CURB
FINISHED GRADE
12.5M REINFORCING
12.5M REINFORCINGRODS AT TIE-INS
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES.2. 30 MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75,
AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5%-7%.
12.5M REINFORCING ROD AT 2000 ON CENTRE
12.5M REINFORCING ROD AT 2000 ON CENTRE
TOP OF SUBGRADE
TOP OF SUBGRADE
ROAD STRUCTURE
ROAD STRUCTURE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
15R
180
75
265
75
200 MAX.150 MIN.
FINISHED GRADE
50R75
375
75
EXTR
UD
ED
SEC
TIO
N
75
-
EXTR
UD
ED S
ECTI
ON
15RF.
O.C
.
L.O
.G.
DROP CURB
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES.2. 30 MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75,
AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5%-7%.
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
15R
25
200
10
250150
25
215
25
4%
B.O
.C.
L.O.G.
T.O.C.
-
900
CONCRETE THRUST BLOCK
A
VALVE
DRAINAGE PIT
SECTION A-A
150
GATE VALVE
WATER MAIN
CONCRETE THRUST BLOCK
A
NOTE: 5.5 KG ZINC ANODE REQUIRED
SEE DRAWING 5.10 CATHODIC PROTECTION
TYPE 'A' VALVE FOR
POLYETHYLENE
6 MIL
MECHANICALLY
CONNECTED
HYDRANT DRAIN
2%
HYDRANT
PRECAST CONCRETE PAD
CONCRETE THRUST
BLOCK
CONCRETE THRUST
BLOCK
OVER GRAVEL
TO HYDRANT
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:
1. THE HYDRANT SHALL BE PLACED ON A PRECAST 600 x
600mm x 150 REINFORCED SULFATE-RESISTANT
CONCRETE PAD OR A PRECAST 600 x 600 x 300
UNREINFORCED CONCRETE PAD.
2. A PIT FOR DRAINAGE 900 WIDE x 450mm LONG x 450 DEEP
SHALL BE EXCAVATED AT THE FOOT OF THE HYDRANT
3. THE SPACE AROUND THE BARREL AND 150mm ABOVE THE
HYDRANT DRAIN SHALL BE FILLED WITH WASHED ROCK.
4. 6MiL POLYETHYLENE SHALL BE PLACED OVER THE TOP OF
THE WASHED ROCK TO PREVENT THE VOIDS FROM BEING
FILLED WITH CLAY.
5. BOTTOM OF HYDRANT FLANGE TO BE MINIMUM 50mm
ABOVE TOP OF SIDEWALK FOR MAINTENANCE SERVICE.
6. IN HIGH WATER TABLE AREAS ENSURE HYDRANT COMES
WITH DRAIN PLUG AND PLUG IS INSTALLED.
7. IF DRAIN PLUG IS INSTALLED; MARK HYDRANT WITH A
50mm x 50mm BLUE SQUARE ON HYDRANT BODY, VISIBLE
FROM ROAD.
450
450
350+/-
50mm
PLAN
PLUMPER PORT FACING
THE ROADWAY
13/05/15
CAST IRON VALVE BOX
HARD SURFACE
TYPE 'C' VALVE FOR
LANDSCAPED SURFACE
VALVE STEM COMPLETE
WITH ROCK GUARD
-
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
P
L
GOOSE NECK
SIDEWALKC
OV
ER
M
IN
.
PIPE MATERIAL NOTES:
1. FOR 25mm PIPE DIAMETERS - USE TYPE K COPPER, PEXa
(CROSS LINKED POLYETHYLENE), PEX-AL-PEX OR ACCEPTED
ALTERNATE.
2. FOR 50mm PIPE DIAMETERS - USE TYPE K COPPER PIPE OR
ACCEPTED ALTERNATIVE.
3. PIPE CLAMP TO BE ALL BRASS OR ACCEPTED ALTERNATE.
4. PEXa PIPE REQUIRES 2" STAINLESS STEEL INSERTS BE
PLACED ON BOTH SIDES OF THE "CC" CONNECTION.
GENERAL NOTES:
1. GOOSENECK IS REQUIRED AT SEWER CROSSINGS AND ARE
TO BE BEDDED WITH SAND AND SANDBAGS.
2. MAINSTOP TAPS SHALL BE A MIN. OF 600mm APART, AND NO
LESS THAN 300mm TO A COUPLING OR COLLAR.
3. WATER SERVICE SHALL BE ONE CONTINUOUS LENGTH.
4. INVERT ELEVATION AT STUBBED END SHALL BE 3.0m BELOW
ESTABLISHED FINISHED GRADE.
5. NO HORIZONTAL GOOSENECK REQUIRED AT MAINSTOP.
6. TAP INTO UPPER PORTION OF WATER MAIN, AT 10 AND 2
O'CLOCK POSITIONS.
7. HOME BUILDER TO INSTALL A COUPLING TO THE TERMINUS OF
THE HOUSE SERVICE WHIP EXPOSED AT SURFACE AND
CONTINUE THE WATER SERVICE TO THE HOUSE.
8. CATHODIC PROTECTION MAY BE A REQUIREMENT IN AREAS
OF HOT SOILS. ENSURE TO WET ANODE PRIOR TO BACKFILL.
EXISTING SEWER MAIN
300m
m S
AN
D
1.0
0.15
2-4m
EASEMENT
STAINLESS STEEL
OPERATING SPINDLE
C/W BRASS CLEVIS
"CC" TO BE SUPPORTED UPON
A SINGLE CHANNEL RECYCLED
PLASTIC BLOCK (MIN. 40x200x200mm).
- DO NOT STRAP/BOLT THE "CC"
TO THE SUPPORTING BLOCK UNLESS
"CC" CHAIR IS DENSO WRAPPED.
- SET THE "CC" CENTERED
UPON THE SUPPORTING BLOCK
AND USE BACKFILL MATERIAL
TO SET THE "CC" PLUMB.
WATERMAIN
MAINSTOP TAPPED
AT CROWN OF MAIN
WITH 1 TO 3 THREADS
SHOWING
DETAIL
SECTION
DETAIL
PVC PIPE
WHEN CITY OF ST. ALBERT BRASS CAP OF THE "CC"
FALLS WITHIN CONCRETE, ENCLOSE IT WITH A SECTION
OF 100mm PVC PIPE, (I.E. ON A DRIVEWAY)
50 x 100 x 1500mm
WOOD STAKE
TOP 1.0m PAINTED
FLOURESCENT RED
"CC"
GALVANIZED SLIDING
UPPER SECTION
22/06/15
GALVANIZED SLIDING
LOWER SECTION
0.5
EPOXY COATED BOOT
TO BE DENSO WRAPPED
PRIOR TO PLACEMENT
OF WASHED ROCK
WASHED ROCK
DRAINAGE PIT
DRAINAGE PIT NOTES:
1. PIT EXCAVATION DIMENSIONS = 300mm LONG x 300mm WIDE x
150mm DEEP BELOW THE "CC" AND SUPPORTING BLOCK.
2.
3. PLACE SUPPORTING BLOCK AND "CC" ASSEMBLY.
4. FILL SPACE AROUND DENSO WRAPPED EPOXY COATED BOOT
WITH WASHED ROCK TO THE TOP OF THE BOOT (200mm).
5. COVER THE WASHED ROCK WITH 6 MIL POLYETHYLENE PRIOR TO
BACKFILL TO PREVENT VOIDS FROM BEING FILLED WITH CLAY.
0.2
0.15
0.3
6 MIL
POLYETHYLENE
OVER WASHED
ROCK
25mm BRASS CAP
CAP SANITARY
SERVICE WITH
REDUCER
SERVICE INSTALLED
AT MIN. 2% SLOPE
-
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
GOOSE NECK
CO
VE
R M
IN
.
PIPE MATERIAL NOTES:
1. FOR 50mm PIPE DIAMETERS - USE TYPE K COPPER PIPE OR
ACCEPTED ALTERNATIVE.
2. PIPE CLAMP TO BE ALL BRASS OR ACCEPTED ALTERNATE.
GENERAL NOTES:
1. GOOSENECK IS REQUIRED AT SEWER CROSSINGS AND ARE
TO BE BEDDED WITH SAND AND SANDBAGS.
2. MAINSTOP TAPS SHALL BE A MIN. OF 600mm APART, AND NO
LESS THAN 300mm TO A COUPLING OR COLLAR.
3. WATER SERVICE SHALL BE ONE CONTINUOUS LENGTH.
4. INVERT ELEVATION AT STUBBED END SHALL BE 3.0m BELOW
ESTABLISHED FINISHED GRADE.
5. NO HORIZONTAL GOOSENECK REQUIRED AT MAINSTOP.
6. TAP INTO UPPER PORTION OF WATER MAIN, AT 10 AND 2
O'CLOCK POSITIONS.
7. CATHODIC PROTECTION MAY BE A REQUIREMENT IN AREAS
OF HOT SOILS. ENSURE TO WET ANODE PRIOR TO BACKFILL.
EXISTING SEWER MAIN
300m
m S
AN
D
STAINLESS STEEL
OPERATING SPINDLE
C/W BRASS CLEVIS
"CC" TO BE SUPPORTED UPON
A SINGLE CHANNEL RECYCLED
PLASTIC BLOCK (MIN. 40x200x200mm).
- DO NOT STRAP/BOLT THE "CC"
TO THE SUPPORTING BLOCK UNLESS
"CC" SADDLE IS DENSO WRAPPED.
- SET THE "CC" CENTERED
UPON THE SUPPORTING BLOCK
AND USE BACKFILL MATERIAL
TO SET THE "CC" PLUMB.
WATERMAIN
MAINSTOP TAPPED
AT CROWN OF MAIN
WITH 1 TO 3 THREADS
SHOWING
DETAIL
SECTION
DETAIL
PVC PIPE
WHEN CITY OF ST. ALBERT BRASS CAP OF THE "CC"
FALLS WITHIN CONCRETE, ENCLOSE IT WITH A SECTION
OF 100mm PVC PIPE, (I.E. ON A DRIVEWAY).
"CC"
GALVANIZED SLIDING
UPPER SECTION
22/06/2015
GALVANIZED SLIDING
LOWER SECTION
EPOXY COATED BOOT
TO BE DENSO WRAPPED
PRIOR TO PLACEMENT
OF WASHED ROCK.
WASHED ROCK
DRAINAGE PIT
DRAINAGE PIT NOTES:
1. PIT EXCAVATION DIMENSIONS = 300mm LONG x 300mm WIDE x
150mm DEEP BELOW THE "CC" AND SUPPORTING BLOCK.
2.
3. PLACE SUPPORTING BLOCK AND "CC" ASSEMBLY.
4. FILL SPACE AROUND DENSO WRAPPED EPOXY COATED BOOT
WITH WASHED ROCK TO THE TOP OF THE BOOT (200mm).
5. COVER THE WASHED ROCK WITH 6 MIL POLYETHYLENE PRIOR TO
BACKFILL TO PREVENT VOIDS FROM BEING FILLED WITH CLAY.
0.2
0.15
0.3
6 MIL
POLYETHYLENE
OVER WASHED
ROCK
50mm BRASS CAP
-
CAST IRON VALVE BOX
(PVC VALVE BOXES
ARE NOT ACCEPTABLE)
VALVE STEM COMPLETE
WITH ROCKGUARD
SAND OR APPROVED BACKFILL
MATERIAL TO BE FILLED
AROUND VALVE UP TO FLANGE
AND FIRMLY TAMPED INTO PLACE.
PLATFORM NOT TO REST ON ANY
PART OF VALVE OR PIPE.
50 X 100 X
600 CONCRETE
BLOCKING
NOTES:
1. 30MPa CONCRETE IN 28 DAYS, SLUMP 25 TO 75, AGGREGATE SIZE 25 MAX, AIR ENTRAINMENT 5% TO 7%
2. CONCRETE THRUST BLOCK REQUIRED FOR ALL WATER SERVICES GREATER THAN OR EQUAL TO 100m DIAMETER.
3. HOT TAP VALVE AND SLEEVE TO BE DENSO-WRAPPED, CATHODICALLY PROTECTED, LEFT IN OPEN POSITION AND
BURIED WITHOUT ROD OR BOX.
WATER SHUT OFF VALVE
SHALL BE TYPE 'A' (SHOWN)
IN HARD SURFACES OR TYPE
'C' IN LANDSCAPED AREAS.
SEE NOTE 3
CATHODIC PROTECTION
5.5kg ZINC ANODE
CONCRETE THRUST
BLOCK
MIN. DEPTH OF COVER 2.60m
MAX. 2.90m
SECT: TYPICAL TVS CONNECTION
(TAPPING VALVE SLEEVE)
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
13/05/15
DENSO-WRAP VALVE
DENSO-WRAP VALVE
-
NO
TE
S:
1. F
OR
C
ON
NE
CT
IO
N T
O T
HE
150m
m S
TO
RM
S
ER
VIC
E R
EF
ER
T
O S
TA
ND
AR
D D
RA
WIN
G N
o. 7.6.
2. P
LA
CE
150 m
m S
TO
RM
S
ER
VIC
E U
PO
N A
N IN
DE
PE
ND
EN
T LE
DG
E M
IN
IM
UM
0.5 m
A
BO
VE
S
AN
IT
AR
Y S
ER
VIC
E IN
VE
RT
.
3. P
IP
E A
LIG
NM
EN
T T
O B
E W
AT
ER
, S
AN
IT
AR
Y T
HE
N S
TO
RM
S
TA
RT
IN
G F
RO
M D
RIV
EW
AY
.
4. E
NS
UR
E S
TO
RM
S
ER
VIC
E IS
IN
ST
ALLE
D U
PO
N A
N IN
DE
PE
ND
EN
T LE
DG
E A
BO
VE
S
AN
IT
AR
Y A
ND
W
AT
ER
.
LE
GE
ND
:
R
ED
M
AR
KE
R P
OS
T 2X
4
P
LU
G
5. D
IM
EN
SIO
NS
A
RE
IN
M
ET
RE
S U
NLE
SS
O
TH
ER
WIS
E N
OT
ED
.
6. H
OU
SE
O
RIE
NT
AT
IO
N M
AY
V
AR
Y.
7. S
ER
VIC
E C
ON
NE
CT
IO
NS
S
HA
LL B
E E
XT
EN
DE
D B
EY
ON
D T
HE
G
AS
LIN
E IN
TO
T
HE
LO
T
TO
T
ER
MIN
AT
E A
T 0.15 m
F
RO
M T
HE
LO
T E
AS
EM
EN
T B
OU
ND
AR
Y.
8. R
ED
UC
E T
HE
150 m
m S
AN
IT
AR
Y S
ER
VIC
E D
OW
N T
O 100 m
m A
ND
C
AP
T
HE
P
LU
G.
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
GA
SG
AS
FA
CE
O
F C
UR
BD
RIV
EW
AY
A
PR
ON
TYPICAL DRIVEWAY
PROPERTY LINE
PR
OP
ER
TY
L
IN
E
LOCATION
VARIES
UTILITY R.O.W.
25
m
m W
AT
ER
S
ER
VIC
E
15
0 m
m
15
0 m
m
CU
RB
S
TO
P (T
YP
)
1.5
0.15
1.0
SA
NIT
AR
Y S
ER
VIC
E
5.0
VA
RIE
S
FR
OM
1
.3
5
TO
2
.0
15
0 m
m S
HA
LL
OW
S
TO
RM
(3
rd
p
ip
e - if p
re
se
nt)
ST
OR
M S
ER
VIC
E
25
m
m W
AT
ER
S
ER
VIC
E
15
0 m
m
SA
NIT
AR
Y S
ER
VIC
E
DR
IV
EW
AY
A
PR
ON
2.02.5
6.5
WA
TE
RM
AIN
SA
NIT
AR
Y S
EW
ER
1.5
0.3
0.3
0.3
0.3
TY
PIC
AL H
OU
SE
LO
CA
TIO
NT
YP
IC
AL H
OU
SE
LO
CA
TIO
N
ST
OP
(T
YP
)C
UR
B
0.15
WA
TE
R S
ER
VIC
E 25 m
m
SA
NIT
AR
Y S
ER
VIC
E 150 m
m
ST
OR
M S
ER
VIC
E 150 m
m
2.6
2.3
MIN
2.0
MIN
2.0
2.6
2.3
RO
AD
S
ID
E 'A
'
WIT
H 6.5m
B
OU
LE
VA
RD
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
SID
EW
AL
K
TYPICAL DRIVEWAY
LOCATION
PROPERTY LINE
9. S
AN
IT
AR
Y A
ND
W
AT
ER
S
ER
VIC
ES
S
HA
LL B
E P
LA
CE
D A
T A
D
EP
TH
O
F B
UR
Y O
F 3.0 m
A
T P
RO
PE
RT
Y LIN
E.
10. S
AN
IT
AR
Y A
ND
S
TO
RM
S
ER
VIC
ES
M
US
T H
AV
E A
M
IN
IM
UM
C
ON
TIN
UO
US
G
RA
DE
O
F 2%
F
RO
M T
HE
M
AIN
T
O P
RO
PE
RT
Y LIN
E.
-
FA
CE
O
F C
UR
B
DR
IV
EW
AY
A
PR
ON
TYPICAL DRIVEWAY
PROPERTY LINE
PR
OP
ER
TY
L
IN
E
LOCATION
VARIES
UTILITY R.O.W.
15
0 m
m
1.5
0.15
1.0
0.5
4.5
VA
RIE
S
FR
OM
1
.3
5
TO
2
.0
ST
OR
M S
EW
ER
ST
OR
M S
ER
VIC
E
PROPERTY LINE
25
m
m W
AT
ER
S
ER
VIC
E
15
0 m
m S
AN
IT
AR
Y S
ER
VIC
E
DR
IV
EW
AY
A
PR
ON
LOCATION
TYPICAL DRIVEWAY
3.0
0.3
0.3
0.3
0.3
TY
PIC
AL H
OU
SE
LO
CA
TIO
NT
YP
IC
AL H
OU
SE
LO
CA
TIO
N
CU
RB
S
TO
P (T
YP
)
0.15
NO
TE
S:
1. F
OR
C
ON
NE
CT
IO
N T
O T
HE
150m
m S
TO
RM
S
ER
VIC
E R
EF
ER
T
O S
TA
ND
AR
D D
RA
WIN
G #7.6
2. P
LA
CE
150 m
m S
TO
RM
S
ER
VIC
E U
PO
N A
N IN
DE
PE
ND
EN
T LE
DG
E M
IN
IM
UM
0.5 m
A
BO
VE
S
AN
IT
AR
Y S
ER
VIC
E IN
VE
RT
.
3. P
IP
E A
LIG
NM
EN
T T
O B
E W
AT
ER
, S
AN
IT
AR
Y T
HE
N S
TO
RM
S
TA
RT
IN
G F
RO
M D
RIV
EW
AY
.
4. E
NS
UR
E S
TO
RM
S
ER
VIC
E IS
IN
ST
ALLE
D U
PO
N A
N IN
DE
PE
ND
EN
T LE
DG
E A
BO
VE
S
AN
IT
AR
Y A
ND
W
AT
ER
.
LE
GE
ND
:
R
ED
M
AR
KE
R P
OS
T 2X
4
P
LU
G
5. D
IM
EN
SIO
NS
A
RE
IN
M
ET
RE
S U
NLE
SS
O
TH
ER
WIS
E N
OT
ED
.
6. H
OU
SE
O
RIE
NT
AT
IO
N M
AY
V
AR
Y.
7. S
ER
VIC
E C
ON
NE
CT
IO
NS
S
HA
LL B
E E
XT
EN
DE
D B
EY
ON
D T
HE
G
AS
LIN
E IN
TO
T
HE
LO
T
TO
T
ER
MIN
AT
E A
T 0.15 m
F
RO
M T
HE
LO
T E
AS
EM
EN
T B
OU
ND
AR
Y.
WA
TE
R S
ER
VIC
E 25 m
m
SA
NIT
AR
Y S
ER
VIC
E 150 m
m
ST
OR
M S
ER
VIC
E 150 m
m
2.6
2.3
MIN
2
.0
MIN
2
.0
2.6
2.3
15
0 m
m S
AN
IT
AR
Y S
ER
VIC
E
CU
RB
S
TO
P (T
YP
)
25
m
m W
AT
ER
S
ER
VIC
E
RO
AD
S
ID
E 'B
'
WIT
H 4.5m
B
OU
LE
VA
RD
Date:
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY
01/04/13
Engineering Municipal Standards
12/06/15
SID
EW
AL
K
8. R
ED
UC
E T
HE
150 m
m S
AN
IT
AR
Y S
ER
VIC
E D
OW
N T
O 100 m
m A
ND
C
AP
T
HE
P
LU
G.
10. S
AN
IT
AR
Y A
ND
S
TO
RM
S
ER
VIC
ES
M
US
T H
AV
E A
M
IN
IM
UM
C
ON
TIN
UO
US
G
RA
DE
O
F 2%
F
RO
M T
HE
M
AIN
T
O T
HE
P
RO
PE
RT
Y LIN
E.
9. S
AN
IT
AR
Y A
ND
W
AT
ER
S
ER
VIC
ES
S
HA
LL B
E P
LA
CE
D A
T A
T D
EP
TH
O
F B
UR
Y O
F 3.0 m
A
T P
RO
PE
RT
Y LIN
E.
-
SECTION A-A
PLAN
A A
300
431
WA
TE
R
184
165
127
48
57
CAST IRON VALVE BOX
VALVE STEM COMPLETE
WITH ROCKGUARD
SAND OF APPROVED BACKFILL MATERIAL
TO BE FILLED AROUND VALVE UP TO FLANGE
AND FIRMLY TAMPED INTO PLACE. PLATFORM
NOT TO REST ON ANY PART OF VALVE OR PIPE
50 X 100 X 600 CONCRETE BLOCKING
VALVE BOX SUPPORT PLATFORM CONSISTS OF 2-3
LAYERS OF RECYCLED PLASTIC TIMBERS
(2x4" OR 2x6" OR 2x8" OR SIMILAR).
PLATFORM SHALL BE TAILORED TO VALVE TYPE AND
HELD TOGETHER BY NAILS OR SCREWS.
PLACE PLATFORM UPON ON TAMPED SAND AT LEVEL
WITH THE FLANGE ON THE VALVE.
(NOTE IF RECYCLED PLASTIC TIMBERS ARE NOT READILY
AVAILABLE, THEN PRESSURE TREATED TIMBERS MAY BE
USED AS AN ALTERNATE MATERIAL).
CORED HANDHOLES
STANDARD WATER PLUG
NOTES:
1. VALVE BOXES SHALL BE EXTERNALLY AND INTERNALLY COATED WITH ASPHALT OR EPOXY COATING.
2. PVC VALVE BOXES ARE NOT PERMITTED.
3. FOR CATHODIC PROTECTION SEE DWG. No. 5.9
4. ALL DIMENSIONS IN MILLIMETERS UNLESS OTHERWISE NOTED.
WATER MAIN OR HYDRANT LEAD
MIN
. D
EP
TH
O
F C
OV
ER
2.65m
Date:
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY
01/04/13
Engineering Municipal Standards
22/06/15
VALVE BOX SUPPORT PLATFORM
-
PVC
5.5 kg (12 lbs)ZINC ANODE
50mm
VALVE
ZINC ANODE5.5 kg ( 12 lb)
CROSS
PVC
50mm
FITTING
BEDDING
ANODE WIRE
PVC
DETAIL
ANODE
VALVE
5.5 kg (12lb)ZINC ANODE
PVC
50m
m PVC
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
REPLACE ANDCOMPACT CLAY
NOTES:1. ALL ANODES TO BE 5.5kg ZINC.2. INSTALL ANODE AT PIPE DEPTH IN NATIVE SOIL.3. MIN. DISTANCE FROM ANODE TO PIPE IS 150mm4. MIN. DISTANCE FROM ANODE TO THRUST BLOCK IS 300mm5. ANODES TO BE EMBEDDED IN UNDISTURBED TRENCH WALL WITH A MIN. OF
50mm OF NATIVE CLAY COVER AROUND ANODE.6. ANODE TO BE 'WETTED' WITH WATER PRIOR TO BACKFILL TO ACTIVATE THE
ANODE.
-
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:1. PIPE CAMP TO BE ALL BRASS OR ACCEPTED EQUIVALENT.2. FOR PEX-AL-PEX PIPE CATHODIC CLAMP REQUIRED TO
SPINDLE ONLY.3. ZINC ANODES TO BE EMBEDDED INTO TRENCH WALL TO
PROVIDE FOR A MINIMUM OF 50mm NATIVE CLAY COMPLETELYCOMPACTED AROUND ANODE.
4. ZINC ANODE TO BE "WETTED" WITH A PAIL OF WATER PRIORTO BACKFILL TO ACTIVATE THE ANODE.
CLAMP
ZINC ANODE
AND COMPACTREPLACE CLAY
505.5 kg.
DETAIL
PL
GAS MAIN
GOOSE NECK
SIDEWALK
CO
VE
R M
IN.
EXISTING SEWER MAIN
SHALLOWSTORM
300m
m S
AN
D
1.0
0.15
1.0
2-4mEASEMENT
STAINLESS STEELOPERATING SPINDLEC/W BRONZE CLEVIS
SUPPORT WITHCONCRETE BLOCK50 x 200 x 300
5.5kg ZINCANODE
WATERMAIN SECTION
CLAMP
-
600 MAX
1200Ø
635Ø
SECTION A-A
PLAN VIEW
300 300
5075
20Ø SAFETY STEPS
UNDISTURBED NATIVE SOIL ORMECHANICALLY COMPACTED TO98% S.P.D.
FINISHED GRADEMANHOLE FRAME & COVER
CONCRETE GRADE RINGS AS REQUIRED
ECCENTRIC CONICAL TOP
PRECAST CONCRETE BARRELS
PRECAST PRE-BENCHED CONCRETE
JOINTS
BEDDING TOFIRST JOINT
MANHOLE BASE C/W PIPE GASKET
C/W CONFINED O-RING GASKET
150°
CL
CLCL
(MAX 3 FOR A TOTAL 450mm)
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
03/10/14
NOTES:1. SAFETY STEPS TO BE SPACED AT 400 MAX.
DISTANCE. LAST STEP TO BE 300 MAX. ABOVEBENCHING.
2. CHANNELING AND BENCHING TO BE FINISHEDTO TROWEL SMOOTHNESS.
3. COMPACT SAND BACKFILL AROUNDMANHOLES TO A MINIMUM OF 98% S.P.D. INLIFTS NOT EXCEEDING 150 MIN.
4. FLAT TOP SECTION TO BE USED FORSHALLOW BURY MANHOLES OF UP TO 1.80m.
5. ALL JOINTS TO BE SET WITH RUBBER GASKETAND FINISHED WITH NON-SHRINK GROUTINSIDE AND OUTSIDE FOR FULLCIRCUMFERENCE.
6. THE PLACEMENT OF THE FIRST LADDERRUNG CAN VARY (BARREL SECTION ORGRADE RING INSERT) BUT MUST NOT EXCEED600MM FROM RIM TO FIRST RUNG.
7. GRADE RINGS MUST BE SET PLUMB TO THEBARREL AND NOT BE STAGGERED.
50-75mm PROJECTIONINTO MANHOLE
WATERTIGHT
MORTARED INSIDE AND OUT
-
25 MPa CONCRETE
SECTION A-A
PLAN
A A
COVER LOCATION
MORTARED INSIDE AND OUT
d
300
20Ø SAFETY STEPS
75
300
50
NOTE:MATCH CROWNS
(MAX 3 FOR A TOTAL 450mm)CONCRETE GRADE RINGS AS REQUIRED
1800
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
03/10/14
NOTES:1. d = 600mmØ TO 1050mmØ2. WHERE UNSUITABLE TRENCH
CONDITIONS EXIST, CRUSHED ROCKWILL BE REQUIRED IN PLACE OFBEDDING MATERIAL BENEATHMANHOLE BASE.
3. FLAT TOP SECTION TO BE USED FORSHALLOW BURY MANHOLES OF UP TO1.80m.
4. SAFETY STEPS TO BE SPACED AT 400MAX. DISTANCE LAST STEP TO BE 300MAX. ABOVE BENCHING.
5. CHANNELING AND BENCHING TO BEFINISHED TO TROWEL SMOOTHNESS.
6. COMPACT SAND BACKFILL AROUNDMANHOLES TO A MINIMUM OF 98%S.P.D. IN LIFT NOT EXCEEDING 150 MIN.
7. ALL JOINTS TO BE SET WITH RUBBERGASKET AND FINISHED WITHNON-SHRINK GROUT INSIDE ANDOUTSIDE FOR FULL CIRCUMFERENCE.
8. THE PLACEMENT OF THE FIRSTLADDER RUNG CAN VARY (BARRELSECTION OR GRADE RING INSERT) BUTMUST NOT EXCEED 600MM FROM RIMTO FIRST RUNG.
9. GRADE RINGS MUST BE SET PLUMB TOTHE BARREL AND NOT BE STAGGERED.
FINISHED GRADE
VARIES
600MAX
100MIN
200 MIN
200 MIN
CEMENTMORTAR
50-75mmPROJECTIONINTOMANHOLE
-
NOTES:
COVER
SECTION A-A
B B
A
A
1200Ø BARREL
GROUT INSIDE & OUTSIDERUBBER GASKET JOINTS
APPROVEDMANHOLE STEPS
CLASS A 25MPa
1200 M
IN. DIA
. PIPE
SECTION B-B
1200Ø
3050 CLASS A BEDDING
BEDDING
MIN. 150MIN. 150
UNDISTURBED NATIVE SOILOR MECHANICALLY COMPACTED TO98% S.P.D..
1200 Ø
1. THIS TYPE OF MANHOLE IS TO BE BUILT ONLY ON MAINS OF1200mm DIAMETER OR LARGER AND WHERE THERE IS NOCHANGE IN DIRECTION OF FLOW, I.E. A"STRAIGHT-THROUGH" FLOW.
2. SAFETY STEPS TO BE SPACED AT 400 MAX. DISTANCE. LASTSTEP TO BE 300 MAX. ABOVE BENCHING.
3. FLAT TOP SECTION TO BE USED FOR SHALLOW BURYMANHOLES OF UP TO 1.80m.
4. CHANNELING AND BENCHING TO BE FINISHED TO TROWELSMOOTHNESS.
5. COMPACT SAND BACKFILL AROUND MANHOLES TO AMINIMUM OF 98% S.P.D. IN LIFTS NOT EXCEEDING 150 MIN.
6. ALL JOINTS TO BE SET WITH RUBBER GASKET AND FINISHEDWITH NON-SHRINK GROUT INSIDE AND OUTSIDE FOR FULLCIRCUMFERENCE.
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
A
SECTION A-A
A
150 150
PLAN SECTION B-B
TEE FITTING, DIAMETER ASINCOMING SEWER
INCOMING SEWER
B B
1:12 SLOPE
MIN. 200
PIPE BELL REQUIRED AT CONCRETE FACE.
1200Ø
CLASS A BEDDING (25MPa CONCRETE)
NOTES:1. PRECAST CONCRETE COMPONENTS TO MEET CURRENT A.S.T.M. C478 STANDARDS.2. CAST IN PLACE CONCRETE TO BE 25 MPa AT 28 DAYS.3. CHANNELING AND BENCHING TO BE FINISHED TO TROWEL SMOOTHNESS.4. COMPACT BACKFILL AROUND MANHOLES TO A MINIMUM OF 98% STANDARD PROCTOR DENSITY.
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
-
INTO MAIN SEWER
FORMING SMOOTH FLOW CHANNEL
ELBOW AND BENCH TO MID-HEIGHT
PROVIDE CONCRETE SUPPORT FOR
TO SECURE DROP PIPE
PIPE STRAPS @ MIN. 500 O/C
USE STAINLESS STEEL
INLET SEWER
MIN. 50 DROP
R=450min. AND
SEWER
INLET
SIZE AS INLET SEWER
PVC DROP PIPE- SAME
SECTION A-A
1
12
SLOPED UPWARD TO MH
MID-HEIGHT OF PIPE AND
BENCHING TO AT LEAST
USE PRE-BENCHED BASE
MANHOLE BARREL
FLO
W C
HA
NN
EL
WALL AT 1:12
6 x 40 STAINLESS STEEL STRAPS
ANCHOR BOLTS
EXPANSION TYPE
BRACKET DETAIL
PIPE INVERT
AA
TEE
DD/MM/YY
DD/MM/YY
Engineering Services
DD/MM/YY Engineering Municipal Standards
NOTES:
1. MAXIMUM INLET SEWER OF 250 DIA.
2. DROP PIPE SIZE TO EQUAL INLET SIZE.
3. TEE FITTING TO BE APPROVED PRIOR TO ORDERING.
4. CAST IN PLACE CONCRETE 25 MPa IN 28 DAYS.
5. MANHOLE BASE TO BE PRE-BENCHED.
6. FOR SANITARY SEWER - MIN DROP 0.75m TO MAX 3.0m THEN EXTERNAL DROP.
7. FOR STORM SEWER - MIN DROP 1.5m TO MAX 3.0m THEN EXTERNAL DROP.
0.75m MIN TO 3.0m MAX
1200 MIN
SECTION THROUGH MANHOLE
-
SLAB TOP TO SUIT FRAME AND COVER
COMPACTED TO 98% S.P.D.APPROVED GRANULAR MATERIAL
PIPE TO BE USED WHERE LEADGRADE. (FULL LENGTH OFLEAD @ MINIMUM OF 1.0%
ENTERS CATCH BASIN)
MIN. 250 DIAMETER CATCH BASIN
PRECAST CONCRETE BASE
600 MIN. SUMP
900Ø
1500 mm MIN.
LC
UNDISTURBED NATIVE SOIL ORMECHANICALLY COMPACTEDTO 98% S.P.D.
WATERTIGHT JOINTS WITH
PIPE
CL
O RINGS GASKETSPRECAST JOINTS C/W CONFINED
NON-SHRINKING GROUT INSIDE AND OUTSIDE FOR FULL CIRCUMFERENCE
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
03/10/14
NOTES:1. PRECAST CONCRETE COMPONENTS TO MEET CURRENT A.S.T.M. C478 STANDARDS.2. CAST IN PLACE CONCRETE TO BE 25 MPa AT 28 DAYS.3. ALL GRADE RING JOINTS TO BE FINISHED WITH RAM NECK MATERIAL AND FINISHED WITH
NON-SHRINK GROUT INSIDE AND OUTSIDE FOR FULL CIRCUMFERENCE. THIS INCLUDESJOINTS BETWEEN GRADE RINGS, GRADE RINGS AND FRAMES, AND BETWEEN GRADERINGS AND SLAB TOPS.
4. ALL BARREL JOINTS TO BE RUBBER GASKET WITH NON-SHRINK GROUT INSIDE & OUT.5. ALL WICK DRAINS TO EXTEND 100mm - 150mm INTO CATCH BASIN.6. GRADE RINGS MUST BE SET PLUMB TO THE BARREL AND NOT BE STAGGERED.
K-7 FRAME AND COVER
CONCRETE GRADE RINGS AS REQUIRED(MAX 3 FOR A TOTAL OF 450mm)
50-75mm
MORTARED INSIDE AND OUT
-
BACK OF TOP OF CURB
FACE OF CURB
LIP OF GUTTER
PRECAST
900 Ø PRECAST CONCRETECATCH BASIN BARREL
MIN 250Ø CATCH BASIN LEAD @ MINIMUM 1.0% GRADE
WATERTIGHT JOINT
SECTION B-B
SECTION A-A
150 MIN
CONCRETE
AA
B
B
98% S.P.D.OR MECHANICALLY COMPACTED TO UNDISTURBED NATIVE SOLID SOIL
900mmØ
MIN 150
MIN 150
GRATE TO BE DEPRESSEDBY 40mm OR TO SECOND COURSEPAVEMENT DEPTH
SIDE INLET TO BE RECESSED MIN 25mmFROM FACE OF CURB
FACE OF CURB
WITH NON-SHRINK
F-51 GUTTER FRAME AND GRATE
GROUT FINISH
1500mmMIN.
600mm MIN.SUMP
CL
PRECAST CONCRETE BASE
C/W CONFINEDO-RINGS GASKETS
SLAB TEE TOP
NOTES:1. WICK DRAINS TO EXTEND 100mm - 150mm INTO CATCH BASIN.2. PRECAST CONCRETE COMPONENTS TO MEET CURRENT ASTM C478 STANDARDS.3. CAST IN PLACE CONCRETE TO BE 25MPa AT 28DAYS.4. SUPPLY NORWOOD TYPE NF-51, TROJAN TYPE K-1A-2 PIECE OR APPROVED EQUIVALENT.
(ALL JOINTS TO BE FINISHED WITH NON-SHRINK GROUTINSIDE AND OUTSIDE FOR FULL CIRCUMFERENCE.)
DD/MM/YY
DD/MM/YY Engineering Services
DD/MM/YY Engineering Municipal Standards
23/04/2014
50-75mm
F-51 SIDE INLET FRAME AND GRATE
(A FULL LENGTH OF PIPE SHALL BE USED WHERETHE CATCHBASIN LEAD ENTERS THE CATCHBASIN.)