appendis3 iqa incoming material inspection flow chart
DESCRIPTION
incoming material inspectionTRANSCRIPT
IQA Incoming Material Inspection Flow Chart
PIC
Receiving
IQA/Receiving
IQA/Receiving
IQA/Receiving
IQA/IA
Buyer
Workcell/Buyer
IQA
IQA
IQA
PS:1. The creation of this flow chart is based on the document 35-IC30-GEN-018 and with new complementarity.
4.All QN concerning the material quality issue must be checked and signed by relevant QE,ME,Mfg and TE(if needed),and the IQA will notify the relevant SQE.
FORM#:50-IC30-GEN-018-06A
2. buyer must close the QN released by the IQA within 48 hours。IQA will announce the QN which can not be closed within the due date
3. For the QN replied by buyer,IQA will check it at least twice in a day。For the urgent QN,buyer should notify the IQA by call or E-mail,IQA must close it within 1 hour.
Start
IQA incoming material inspection
Incoming material inspection
pass or not?
release the QN through the SAP
Buyer deal with the QN as the coordinator
execute the usable decision
can be used or not
Check the packing,delivery
date and the manufacturer
DTS or not?
not
distinguish the RoHS material,store in waiting pass
to stockroom area
store in warehouse
Yes
buyer follows the QN, until the QN is closed by the workcell decision
buyer reply the IQA directly, or provide the usable deciding (UD01-UD10)
finish the inspection, close the Qn
End
Yes
not
not
Yes