app 20.75 database

229
Application 20.75 Modbus Database US Liquid Pulse Meter, KF Curve Modbus Index Description Data Type Hex Value Access Notes Level A,B,C Locked FP Locked Serial Info: This data is accessed using Modbus function code 03 for reads and 16 for writes. Boolean data bit are packed 8 to a byte. 1 Custom Data Packet 1 Cust Pack 0001 R/W R/W, , R R (see indexes 3001 to 3040) 201 Custom Data Packet 2 Cust Pack 00C9 R/W R/W, , R R (see indexes 3041 to 3056) 401 Custom Data Packet 3 Cust Pack 0191 R/W R/W, , R R (see indexes 3057 to 3096) Info: This data is accessed using Modbus function code 03. For Method 2, the register count is the desired record number. 701 Archive 1 Data Record (Method 1) Archive 02BD R R, , R 702 Archive 2 Data Record (Method 1) Archive 02BE R R, , R 703 Archive 3 Data Record (Method 1) Archive 02BF R R, , R 704 Archive 4 Data Record (Method 1) Archive 02C0 R R, , R 705 Archive 5 Data Record (Method 1) Archive 02C1 R R, , R 706 Archive 6 Data Record (Method 1) Archive 02C2 R R, , R 707 Archive 7 Data Record (Method 1) Archive 02C3 R R, , R 708 Archive 8 Data Record (Method 1) Archive 02C4 R R, , R 709 Archive 9 Data Record (Method 1) Archive 02C5 R R, , R 710 Archive 10 Data Record (Method 1) Archive 02C6 R R, , R 711 Alarm Log Data Record (Method 1) Archive 02C7 R R, , R 712 Audit Log Data Record (Method 1) Archive 02C8 R R, , R 721 Archive 1 Data Record (Method 2) Archive 02D1 R R, , R 722 Archive 2 Data Record (Method 2) Archive 02D2 R R, , R 723 Archive 3 Data Record (Method 2) Archive 02D3 R R, , R 724 Archive 4 Data Record (Method 2) Archive 02D4 R R, , R 725 Archive 5 Data Record (Method 2) Archive 02D5 R R, , R 726 Archive 6 Data Record (Method 2) Archive 02D6 R R, , R 727 Archive 7 Data Record (Method 2) Archive 02D7 R R, , R 728 Archive 8 Data Record (Method 2) Archive 02D8 R R, , R 729 Archive 9 Data Record (Method 2) Archive 02D9 R R, , R 730 Archive 10 Data Record (Method 2) Archive 02DA R R, , R 731 Alarm Log Data Record (Method 2) Archive 02DB R R, , R 732 Audit Log Data Record (Method 2) Archive 02DC R R, , R Page1 of 229 1/25/2013

Upload: eka-pramudia-santoso

Post on 11-Jan-2016

40 views

Category:

Documents


0 download

DESCRIPTION

App 20.75 Database

TRANSCRIPT

Page 1: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Info: This data is accessed using Modbus function code 03 for reads and 16 for writes. Boolean data bit are packed 8 to a byte.

1 Custom Data Packet 1 Cust Pack 0001 R/W R/W, ‐, R R(see indexes 3001 to 3040)

201 Custom Data Packet 2 Cust Pack 00C9 R/W R/W, ‐,  R R(see indexes 3041 to 3056)

401 Custom Data Packet 3 Cust Pack 0191 R/W R/W, ‐, R R(see indexes 3057 to 3096)

Info: This data is accessed using Modbus function code 03. For Method 2, the register count is the desired record number.

701 Archive 1 Data Record (Method 1) Archive 02BD R R, ‐, R702 Archive 2 Data Record (Method 1) Archive 02BE R R, ‐, R703 Archive 3 Data Record (Method 1) Archive 02BF R R, ‐, R704 Archive 4 Data Record (Method 1) Archive 02C0 R R, ‐, R705 Archive 5 Data Record (Method 1) Archive 02C1 R R, ‐, R706 Archive 6 Data Record (Method 1) Archive 02C2 R R, ‐, R707 Archive 7 Data Record (Method 1) Archive 02C3 R R, ‐, R708 Archive 8 Data Record (Method 1) Archive 02C4 R R, ‐, R709 Archive 9 Data Record (Method 1) Archive 02C5 R R, ‐, R710 Archive 10 Data Record (Method 1) Archive 02C6 R R, ‐, R711 Alarm Log Data Record (Method 1) Archive 02C7 R R, ‐, R712 Audit Log Data Record (Method 1) Archive 02C8 R R, ‐, R

721 Archive 1 Data Record (Method 2) Archive 02D1 R R, ‐, R722 Archive 2 Data Record (Method 2) Archive 02D2 R R, ‐, R723 Archive 3 Data Record (Method 2) Archive 02D3 R R, ‐, R724 Archive 4 Data Record (Method 2) Archive 02D4 R R, ‐, R725 Archive 5 Data Record (Method 2) Archive 02D5 R R, ‐, R726 Archive 6 Data Record (Method 2) Archive 02D6 R R, ‐, R727 Archive 7 Data Record (Method 2) Archive 02D7 R R, ‐, R728 Archive 8 Data Record (Method 2) Archive 02D8 R R, ‐, R729 Archive 9 Data Record (Method 2) Archive 02D9 R R, ‐, R730 Archive 10 Data Record (Method 2) Archive 02DA R R, ‐, R731 Alarm Log Data Record (Method 2) Archive 02DB R R, ‐, R732 Audit Log Data Record (Method 2) Archive 02DC R R, ‐, R

Page1 of 229 1/25/2013

Page 2: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

751 Archive 1 Date/Time Record (Method 1) Arch Date 02EF R R, ‐, R752 Archive 2 Date/Time Record (Method 1) Arch Date 02F0 R R, ‐, R753 Archive 3 Date/Time Record (Method 1) Arch Date 02F1 R R, ‐, R754 Archive 4 Date/Time Record (Method 1) Arch Date 02F2 R R, ‐, R755 Archive 5 Date/Time Record (Method 1) Arch Date 02F3 R R, ‐, R756 Archive 6 Date/Time Record (Method 1) Arch Date 02F4 R R, ‐, R757 Archive 7 Date/Time Record (Method 1) Arch Date 02F5 R R, ‐, R758 Archive 8 Date/Time Record (Method 1) Arch Date 02F6 R R, ‐, R759 Archive 9 Date/Time Record (Method 1) Arch Date 02F7 R R, ‐, R760 Archive 10 Date/Time Record (Method 1) Arch Date 02F8 R R, ‐, R

761 Alarm Log Date/Time Record (Method 1) Arch Date 02F9 R R, ‐, R762 Audit Log Date/Time Record (Method 1) Arch Date 02FA R R, ‐, R

771 Archive 1 Date/Time Record (Method 2) Arch Date 0303 R R, ‐, R772 Archive 2 Date/Time Record (Method 2) Arch Date 0304 R R, ‐, R773 Archive 3 Date/Time Record (Method 2) Arch Date 0305 R R, ‐, R774 Archive 4 Date/Time Record (Method 2) Arch Date 0306 R R, ‐, R775 Archive 5 Date/Time Record (Method 2) Arch Date 0307 R R, ‐, R776 Archive 6 Date/Time Record (Method 2) Arch Date 0308 R R, ‐, R777 Archive 7 Date/Time Record (Method 2) Arch Date 0309 R R, ‐, R778 Archive 8 Date/Time Record (Method 2) Arch Date 030A R R, ‐, R779 Archive 9 Date/Time Record (Method 2) Arch Date 030B R R, ‐, R780 Archive 10 Date/Time Record (Method 2) Arch Date 030C R R, ‐, R

781 Alarm Log Date/Time Record (Method 2) Arch Date 030D R R, ‐, R782 Audit Log Date/Time Record (Method 2) Arch Date 030E R R, ‐, R

Indexes 1001 through 1024 indicate the status of the flow computer physical digital I/O points.

Info: Never set a physical I/O point which has been assigned as an input as this could cause a DC voltage to appear on the input terminals of that point which may conflict with any voltage already present on those terminals.

1001 ‐ 1024 Digital I/O Point 1 ‐ 24 Boolean 03E9 R/W R/W, ‐, R R

Indexes 1025 through 1088 contain to results of programmable boolean statements 25 through 88.

Info: Boolean data is accessed using Modbus function codes 01 for reads and 05 for single point writes and 15 for multiple point writes. 

Page2 of 229 1/25/2013

Page 3: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Boolean data is packed 8 points to a byte when reading. 

Info: Boolean data points 1057‐1088 are available for user alarms. Example: 1030:1088=1002 1088: High Filter DP. Make 1088 follows the status of Digital Point #2. When true, Alarm message will be placed in the Alarm log and on Alarm screen. 

1025 ‐ 1088 Boolean Point 25 ‐ 88 Boolean 0401 R/W You may read from or write to these variables, but anything that you write may be overwritten by the flow computer depending upon the logic functions programmed into the logic statement.

 R/W, ‐, R   R

1089 ‐ 1099 Programmable Pulses Boolean 0441 R Points 1089 to 1099 are paired with floating point variables 7089 to 7099. Numeric data placed in 7089 can be output as pulses by assigning a digital I/O point to 1089.

  R, ‐, R   R

Info: Registers 1n01‐1n04 (n=1,2,3,4) & 1801‐1804Used to assign accumulators to front panel counters or digital I/O point.

1101 Meter 1 Gross Pulses Boolean 044D R Used to assign accumulator to the front panel counters or digital I/O points.

  R, ‐, R   R

1102 Meter 1 Net (GSV) Pulses Boolean 044E R Used to assign accumulator to the front panel counters or digital I/O points.

  R, ‐, R   R

1103 Meter 1 Mass Pulses Boolean 044F R Used to assign accumulator to the front panel counters or digital I/O points.

  R, ‐, R   R

1104 Meter 1 Net Standard Volume (NSV) Pulses

Boolean 0450 R Used to assign accumulator to the front panel counters or digital I/O points.

  R, ‐, R   R

1105 Meter 1 Active Flag Boolean 0451 R True if flow pulses above threshold frequency.   R, ‐, R   R

1106 Meter 1 is being Proved Boolean 0452 R Activates during proving of this meter.   R, ‐, R   R

Page3 of 229 1/25/2013

Page 4: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1107 Meter 1 New Alarm Flag Boolean 0453 R Clears if alarm acknowledged.   R, ‐, R   R

1108 Meter 1 Batch End Acknowledge (Toggle ON/OFF)

Boolean 0454 R   R, ‐, R   R

1109 Meter 1 Auto Prove Problem Boolean 0455 R Ten consecutive attempts to auto‐prove have failed.   R, ‐, R   R

1110 Meter 1 Batch Preset Reached Boolean 0456 R Batch total equal or exceeds the batch preset   R, ‐, R R

1111 Meter 1 Batch Preset Warning Flag Boolean 0457 R  R, ‐, R R1112 Meter 1 Batch End Acknowledge (500mS) Boolean 0458 R   R, ‐, R R

1113 Meter 1 Calculation Out of Range Alarm Boolean 0459 R  R, ‐, R R1114 Meter 1 Density Pressure Override In Use Boolean 045A R   R, ‐, R R

1115 Meter 1 Auto Prove Flag Boolean 045B R Indicates that meter #1 will be automatically proved based on changes in flow rate or meter run time.

  R, ‐, R R

1116 Meter 1 Temperature Override In Use Boolean 045C R  R, ‐, R R1117 Meter 1 Pressure Override In Use Boolean 045D R  R, ‐, R R1118 Meter 1 Density Override In Use Boolean 045E R  R, ‐, R R1119 Meter 1 Density Temperature Override In 

UseBoolean 045F R   R, ‐, R R

1120 Meter 1 Flowrate Low Low Alarm Boolean 0460 R  R, ‐, R R1121 Meter 1 Flowrate Low Alarm Boolean 0461 R  R, ‐, R R1122 Meter 1 Flowrate High Alarm Boolean 0462 R  R, ‐, R R1123 Meter 1 Flowrate High High Alarm Boolean 0463 R  R, ‐, R R1124 Meter 1 Temperature Transducer Fail 

LowBoolean 0464 R   R, ‐, R R

1125 Meter 1 Temperature Low Alarm Boolean 0465 R  R, ‐, R R1126 Meter 1 Temperature High Alarm Boolean 0466 R  R, ‐, R R1127 Meter 1 Temperature Transducer Fail 

HighBoolean 0467 R   R, ‐, R R

1128 Meter 1 Pressure Transducer Fail Low Boolean 0468 R  R, ‐, R RPage4 of 229 1/25/2013

Page 5: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1129 Meter 1 Pressure Low Alarm Boolean 0469 R  R, ‐, R R1130 Meter 1 Pressure High Alarm Boolean 046A R  R, ‐, R R1131 Meter 1 Pressure Transducer Fail High Boolean 046B R  R, ‐, R R1132 Meter 1 Gravity/Density Transducer Fail 

LowBoolean 046C R   R, ‐, R R

1133 Meter 1 Gravity/Density Low Alarm Boolean 046D R  R, ‐, R R1134 Meter 1 Gravity/Density High Alarm Boolean 046E R  R, ‐, R R1135 Meter 1 Gravity/Density Transducer Fail 

HighBoolean 046F R   R, ‐, R R

1136 Meter 1 Dens.Temperature Transducer Fail Low

Boolean 0470 R   R, ‐, R R

1137 Meter 1 Dens.Temperature Low Alarm Boolean 0471 R  R, ‐, R R1138 Meter 1 Dens.Temperature High Alarm Boolean 0472 R  R, ‐, R R1139 Meter 1 Dens.Temperature Transducer 

Fail HighBoolean 0473 R   R, ‐, R R

1144 Meter 1 Dens. Pressure Transducer Fail Low

Boolean 0478 R   R, ‐, R R

1145 Meter 1 Dens. Pressure Low Alarm Boolean 0479 R  R, ‐, R R1146 Meter 1 Dens. Pressure High Alarm Boolean 047A R  R, ‐, R R1147 Meter 1 Dens. Pressure Transducer Fail 

HighBoolean 047B R   R, ‐, R R

1148 Meter 1 Dual Pulse comparator Alarm Boolean 047C R  R, ‐, R R1149 Meter 1 Dual Pulse Channel A Failed Boolean 047D R  R, ‐, R R1150 Meter 1 Dual Pulse Channel B Failed Boolean 047E R  R, ‐, R R1151 Meter 1 Dual Pulse Channel A or B Failed Boolean 047F R   R, ‐, R R

1154 Meter 1 Any Alarm (Existing or New Alarm)

Boolean 0482 R   R, ‐, R R

1155 Meter 1 Meter Inactive 500 mS Flag Boolean 0483 R  R, ‐, R R1156 Meter 1 Batch In Progress Flag Boolean 0484 R  R, R, R R

Page5 of 229 1/25/2013

Page 6: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1157 Meter 1 Batch Start Acknowledge Boolean 0485 R Set for 500mS when 1727 ‐1730 command is received.   R, R, R R

1158 Meter 1 Batch Suspended Boolean 0486 R True when batch is in progress but meter is inactive.   R, R, R R

1159 Meter 1 Day End Flag (500mS) Boolean 0487 R  R, ‐, R R

Info: Registers 1n60‐1n75 Data obtained via RS‐485 link with Micro Mo on device.

1160 Meter 1 Micro Motion EPROM Checksum Fail

Boolean 0488 R   R, ‐, R R

1161 Meter 1 Micro Motion Transmitter Config Changed

Boolean 0489 R   R, ‐, R R

1162 Meter 1 Micro Motion Sensor Failure Boolean 048A R  R, ‐, R R1163 Meter 1 Micro Motion Temperature 

Sensor FailureBoolean 048B R   R, ‐, R R

1164 Meter 1 Micro Motion Input Overrange Boolean 048C R  R, ‐, R R1165 Meter 1 Micro Motion Frequency 

OverrangeBoolean 048D R   R, ‐, R R

1166 Meter 1 Micro Motion Transmitter Not Configured

Boolean 048E R   R, ‐, R R

1167 Meter 1 Micro Motion Real‐Time Interrupt Fail

Boolean 048F R   R, ‐, R R

1168 Meter 1 Micro Motion Milliamp Output Saturated

Boolean 0490 R   R, ‐, R R

1169 Meter 1 Micro Motion Milliamp Output Fixed

Boolean 0491 R   R, ‐, R R

1170 Meter 1 Micro Motion Density Out Of Limits

Boolean 0492 R   R, ‐, R R

Page6 of 229 1/25/2013

Page 7: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1171 Meter 1 Micro Motion Zeroing Operation Failure

Boolean 0493 R   R, ‐, R R

1172 Meter 1 Micro Motion Transmitter Electronics Fail

Boolean 0494 R   R, ‐, R R

1173 Meter 1 Micro Motion Slug Flow Boolean 0495 R  R, ‐, R R1174 Meter 1 Micro Motion Self Calibration In 

ProgressBoolean 0496 R   R, ‐, R R

1175 Meter 1 Micro Motion Power Reset Occurred

Boolean 0497 R   R, ‐, R R

1176 Meter 1 Re‐Calculate Batch Report (500 mS Flag)

Boolean 0498 R   R, ‐, R R

1177 Meter 1 Correctable Totalizer Error Occurrec

Boolean 0499 R Primary totalizer checksum error secondary totalizer checksum OK.

  R, ‐, R R

1178 Meter 1 Non Correctable Totalizer Error Boolean 049A R Primary and secondary totalizers reset to zero because both checksum incorrect.

  R, ‐, R R

1183 Meter 1 HART device type mismatch the Temperature assignment

Boolean 049F R   R, ‐, R R

1184 Meter 1 HART device type mismatch the Pressure assignment

Boolean 04A0 R   R, ‐, R R

1185 Meter 1 HART device type mismatch the Density Temp assignment

Boolean 04A1 R   R, ‐, R R

1186 Meter 1 HART device type mismatch the Density Pressure assignment

Boolean 04A2 R   R, ‐, R R

1187 Meter 1 Temperature HART device lost communication alarm

Boolean 04A3 R   R, ‐, R R

Page7 of 229 1/25/2013

Page 8: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1188 Meter 1 Pressure HART device lost communication alarm

Boolean 04A4 R   R, ‐, R R

1189 Meter 1 Density Temperature HART device lost communication alarm

Boolean 04A5 R   R, ‐, R R

1190 Meter 1 Density Pressure HART device lost communication alarm

Boolean 04A6 R   R, ‐, R R

1198 Meter 1 Batch End Flag ‐ No Stack Operation.

Boolean 04AE R   R, ‐, R R

1201 ‐ 1299 Meter 2 Status (Same as 1101 ‐ 1199)

Boolean 04B1 R   R, ‐, R R

1301 ‐ 1399 Meter 3 Status (Same as 1101 ‐ 1199)

Boolean 0515 R   R, ‐, R R

1401 ‐ 1499 Meter 4 Status (Same as 1101 ‐ 1199)

Boolean 0579 R   R, ‐, R R

Indexes 1501 through 1699 are uncommitted boolean flags which can be used as scratchpad variables used to store results of boolean statementsor data received over a modbus link.

1501 ‐ 1649 Scratchpad Boolean Boolean 05DD R/W R/W, ‐, R R1650 ‐ 1699 Scratchpad One‐shot (2Sec) Boolean 0672 R/W These boolean points remain activated for exactly 2 

seconds after they have been written to. R/W, ‐, R R

The following command registers most are edge triggered and reset automatically after the action occurs.ie: You set them and forget about them.

Info: Registers 1700‐1800 Hardware Interaction: Unreliable operation will result if a command which has been assigned to a digital I/O point directly also needs to be activThis is because the ON/Off state of the digital I/O point overwrites the command point every 100msec and most command point actions are only triggered every 500 msec

1701 Prover Seal OK Boolean 06A5 R/W R/W, ‐, R R1702 End Batch Station Boolean 06A6 R/W R/W, W, R Y R

Page8 of 229 1/25/2013

Page 9: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1703 End Batch Meter 1 Boolean 06A7 R/W R/W, W, R Y R1704 End Batch Meter 2 Boolean 06A8 R/W R/W, W, R Y R1705 End Batch Meter 3 Boolean 06A9 R/W R/W, W, R Y R1706 End Batch Meter 4 Boolean 06AA R/W R/W, W, R Y R1707 Station Change Product Strobe Boolean 06AB R/W R/W, ‐, R R1708 Prove Request Meter 1 Boolean 06AC R/W R/W, W, R Y R1709 Prove Request Meter 2 Boolean 06AD R/W R/W, W, R Y R1710 Prove Request Meter 3 Boolean 06AE R/W R/W, W, R Y R1711 Prove Request Meter 4 Boolean 06AF R/W R/W, W, R Y R1712 Alarm Acknowledge Boolean 06B0 R/W R/W, ‐, R Y R1713 Reset Power Fail Boolean 06B1 R/W R/W, ‐, R R1714 Trial Prove Request Meter 1 Boolean 06B2 R/W R/W, W, R Y R1715 Trial Prove Request Meter 2 Boolean 06B3 R/W R/W, W, R Y R1716 Trial Prove Request Meter 3 Boolean 06B4 R/W R/W, W, R Y R1717 Trial Prove Request Meter 4 Boolean 06B5 R/W R/W, W, R Y R1718 Prove Abort Request Boolean 06B6 R/W R/W, W, R Y R1719 Request Snapshot Report Boolean 06B7 R/W R/W, ‐, R Y R1720 Send Snapshot Report to Modbus Buffer Boolean 06B8 R/W R/W, ‐, R R1721 Send Alarm Report to Modbus Buffer Boolean 06B9 R/W R/W, ‐, R R1722 PID 1 Permissive Boolean 06BA R/W R/W, ‐, R R1723 PID 2 Permissive Boolean 06BB R/W R/W, ‐, R R1724 PID 3 Permissive Boolean 06BC R/W R/W, ‐, R R1725 PID 4 Permissive Boolean 06BD R/W R/W, ‐, R R1726 Prover Start Permissive Boolean 06BE R/W R/W, ‐, R R1727 PID 1 Start Command Boolean 06BF R/W R/W, ‐, R Y R1728 PID 2 Start Command Boolean 06C0 R/W R/W, ‐, R Y R1729 PID 3 Start Command Boolean 06C1 R/W R/W, ‐, R Y R1730 PID 4 Start Command Boolean 06C2 R/W R/W, ‐, R Y R1731 Compact Prover Piston Downstream Boolean 06C3 R/W R/W, ‐, R R1732 Alarm Acknowledge Meter 1 Boolean 06C4 R/W R/W, ‐, R R1733 Alarm Acknowledge Meter 2 Boolean 06C5 R/W R/W, ‐, R R1734 Alarm Acknowledge Meter 3 Boolean 06C6 R/W R/W, ‐, R R1735 Alarm Acknowledge Meter 4 Boolean 06C7 R/W R/W, ‐, R R1736 Disable Meter 1 Boolean 06C8 R/W R/W, ‐, R R1737 Disable Meter 2 Boolean 06C9 R/W R/W, ‐, R R1738 Disable Meter 3 Boolean 06CA R/W R/W, ‐, R R1739 Disable Meter 4 Boolean 06CB R/W R/W, ‐, R R1741 Remote Up Arrow Key Boolean 06CD R/W R/W, ‐, R R

Page9 of 229 1/25/2013

Page 10: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1742 Remote Down Arrow Key Boolean 06CE R/W R/W, ‐, R R1743 Product Select Bit 0 Boolean 06CF R/W R/W, ‐, R R1744 Product Select Bit 1 Boolean 06D0 R/W R/W, ‐, R R1745 Product Select Bit 2 Boolean 06D1 R/W R/W, ‐, R R1746 Product Select Bit 3 Boolean 06D2 R/W R/W, ‐, R R1747 Change Product Strobe Meter 1 Boolean 06D3 R/W R/W, ‐, R R1748 Change Product Strobe Meter 2 Boolean 06D4 R/W R/W, ‐, R R1749 Change Product Strobe Meter 3 Boolean 06D5 R/W R/W, ‐, R R1750 Change Product Strobe Meter 4 Boolean 06D6 R/W R/W, ‐, R R1751 Freeze All Analog Inputs Boolean 06D7 R/W R/W, ‐, R R1752 PID 1 Second Permissive Boolean 06D8 R/W R/W, ‐, R R1753 PID 2 Second Permissive Boolean 06D9 R/W R/W, ‐, R R1754 PID 3 Second Permissive Boolean 06DA R/W R/W, ‐, R R1755 PID 4 Second Permissive Boolean 06DB R/W R/W, ‐, R R1760 Freeze All Totalizers Boolean 06E0 R/W R/W, ‐, R R1761 Disable Station Boolean 06E1 R/W R/W, ‐, R R1762 Remote Print Previous Batch Report 1 Boolean 06E2 R/W R/W, ‐, R R1763 Remote Print Previous Batch Report 2 Boolean 06E3 R/W R/W, ‐, R R1764 Remote Print Previous Batch Report 3 Boolean 06E4 R/W R/W, ‐, R R1765 Remote Print Previous Batch Report 4 Boolean 06E5 R/W R/W, ‐, R R1766 Remote Print Previous Batch Report 5 Boolean 06E6 R/W R/W, ‐, R R1767 Remote Print Previous Batch Report 6 Boolean 06E7 R/W R/W, ‐, R R1768 Remote Print Previous Batch Report 7 Boolean 06E8 R/W R/W, ‐, R R1769 Remote Print Previous Batch Report 8 Boolean 06E9 R/W R/W, ‐, R R1770 Remote Print Previous Daily Report 1 Boolean 06EA R/W R/W, ‐, R R1771 Remote Print Previous Daily Report 2 Boolean 06EB R/W R/W, ‐, R R1772 Remote Print Previous Daily Report 3 Boolean 06EC R/W R/W, ‐, R R1773 Remote Print Previous Daily Report 4 Boolean 06ED R/W R/W, ‐, R R1774 Remote Print Previous Daily Report 5 Boolean 06EE R/W R/W, ‐, R R1775 Remote Print Previous Daily Report 6 Boolean 06EF R/W R/W, ‐, R R1776 Remote Print Previous Daily Report 7 Boolean 06F0 R/W R/W, ‐, R R1777 Remote Print Previous Daily Report 8 Boolean 06F1 R/W R/W, ‐, R R1778 Remote Print Previous Prove Report 1 Boolean 06F2 R/W R/W, ‐, R R1779 Remote Print Previous Prove Report 2 Boolean 06F3 R/W R/W, ‐, R R1780 Remote Print Previous Prove Report 3 Boolean 06F4 R/W R/W, ‐, R R1781 Remote Print Previous Prove Report 4 Boolean 06F5 R/W R/W, ‐, R R1782 Remote Print Previous Prove Report 5 Boolean 06F6 R/W R/W, ‐, R R1783 Remote Print Previous Prove Report 6 Boolean 06F7 R/W R/W, ‐, R R

Page10 of 229 1/25/2013

Page 11: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1784 Remote Print Previous Prove Report 7 Boolean 06F8 R/W R/W, ‐, R R1785 Remote Print Previous Prove Report 8 Boolean 06F9 R/W R/W, ‐, R R1786 Remote Print Alarm Report Boolean 06FA R/W R/W, ‐, R R1787 Implement Last Proved Meter Factor Boolean 06FB R/W R/W, R/W, R R1788 PID 1 Shutdown Command Boolean 06FC R/W R/W, ‐, R Y R1789 PID 2 Shutdown Command Boolean 06FD R/W R/W, ‐, R Y R1790 PID 3 Shutdown Command Boolean 06FE R/W R/W, ‐, R Y R1791 PID 4 Shutdown Command Boolean 06FF R/W R/W, ‐, R Y R1792 PID 1 Stop Command Boolean 0700 R/W R/W, ‐, R Y R1793 PID 2 Stop Command Boolean 0701 R/W R/W, ‐, R Y R1794 PID 3 Stop Command Boolean 0702 R/W R/W, ‐, R Y R1795 PID 4 Stop Command Boolean 0703 R/W R/W, ‐, R Y R1796 Archive Run Command Boolean 0704 R/W R/W, ‐, R N R1797 Re‐configure Archive File Command Boolean 0705 R/W R/W, ‐, R N R1798 Station Batch Re‐Calculate & Print 

CommandBoolean 0706 R/W  R/W, ‐, R Y R

1801 Station Positive Gross Pulses Boolean 0709 R  R, ‐, R R1802 Station Positive Net (GSV) Pulses Boolean 070A R  R, ‐, R R1803 Station Positive Mass Pulses Boolean 070B R  R, ‐, R R1804 Station Positive Net Standard Volume 

(NSV)Boolean 070C R   R, ‐, R R

1805 Station Negative Gross Volume Boolean 070D R  R, ‐, R R1806 Station Negative Net Volume (NSV) Boolean 070E R  R, ‐, R R1807 Station Negative Mass Boolean 070F R  R, ‐, R R1808 Station Negative Net Standard Volume 

(NSV)Boolean 0710 R   R, ‐, R R

1809 Station Flowrate Low Low Alarm Boolean 0711 R Alarm checking is based on gross flowrate.   R, ‐, R R

1810 Station Flowrate Low Alarm Boolean 0712 R Alarm checking is based on gross flowrate.   R, ‐, R R

1811 Station Flowrate High Alarm Boolean 0713 R Alarm checking is based on gross flowrate.   R, ‐, R R

1812 Station Flowrate High High Alarm Boolean 0714 R Alarm checking is based on gross flowrate.   R, ‐, R R

1813 Station Gravity Rate of Change Flag Boolean 0715 R  R, ‐, R RPage11 of 229 1/25/2013

Page 12: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1814 Station Delayed, Gravity Rate of Change Flag

Boolean 0716 R   R, ‐, R R

1815 Station Any Alarm (Existing or New Alarm)

Boolean 0717 R   R, ‐, R R

1816 Station New Alarm Flag Boolean 0718 R  R, ‐, R R1817 Station Batch End Acknowledge (Toggle 

ON/OFF)Boolean 0719 R   R, ‐, R R

1818 Station Batch Preset Warning Flag Boolean 071A R  R, ‐, R R1819 Station Batch Preset Reached Boolean 071B R  R, ‐, R R1820 Station Product ID Bit 0 Boolean 071C R  R, ‐, R R1821 Station Product ID Bit 1 Boolean 071D R  R, ‐, R R1822 Station Product ID Bit 2 Boolean 071E R  R, ‐, R R1823 Station Product ID Bit 3 Boolean 071F R  R, ‐, R R1824 Run Switching Threshold Flag 1 Boolean 0720 R  R, ‐, R R1825 Run Switching Threshold Flag 2 Boolean 0721 R  R, ‐, R R1826 Run Switching Threshold Flag 3 Boolean 0722 R  R, ‐, R R1827 Leak Detection Freeze Command Was 

ReceivedBoolean 0723 R   R, ‐, R R

1828 Contract Day Start Flag (500mS) Boolean 0724 R  R, ‐, R R1829 Power Failed Flag (Set after power up) Boolean 0725 R  R, ‐, R R1830 Print Buffer Full Flag Boolean 0726 R  R, ‐, R R1831 Hour Start Flag (500mS) Boolean 0727 R  R, ‐, R R1832 Week Start Flag (Set at Contract Day Start 

Monday)Boolean 0728 R   R, ‐, R R

1833 Month Start Flag (Day Start 1st Day of Month)

Boolean 0729 R   R, ‐, R R

1834 Year Start Flag (Day Start Jan.1st) Boolean 072A R  R, ‐, R R1835 Station Batch End Flag (500mS) Boolean 072B R  R, ‐, R R1836 Local Snapshot Printed (500mS) Boolean 072C R  R, ‐, R R1837 EPROM Error Detected Boolean 072D R  R, ‐, R R1838 Peer to Peer Master Flag Boolean 072E R  R, ‐, R R

Page12 of 229 1/25/2013

Page 13: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1839 Station Batch End Flag(500mS) ‐ No Stack Operation

Boolean 072F R   R, ‐, R R

Info:  Registers 184‐1841 The system limits the maximum number of statement evaluations to 100 to protect against possible lock‐ups due to recursive loops. Any additional statement evaluations are ignored.

1840 Boolean Statement Alarm Boolean 0730 R The system limits the maximum number of statement evaluations to 100 to protect against possible lock‐ups due to recursive loops.

  R, ‐, R R

1841 Variable Statement Alarm Boolean 0731 R The system limits the maximum number of statement evaluations to 100 to protect against possible lock‐ups due to recursive loops.

  R, ‐, R R

1842 Peer to Peer Transaction 1 Communication Error

Boolean 0732 R   R, ‐, R R

1843 Peer to Peer Transaction 2 Communication Error

Boolean 0733 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1844 Peer to Peer Transaction 3 Communication Error

Boolean 0734 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1845 Peer to Peer Transaction 4 Communication Error

Boolean 0735 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1846 Peer to Peer Transaction 5 Communication Error

Boolean 0736 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1847 Peer to Peer Transaction 6 Communication Error

Boolean 0737 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1848 Peer to Peer Transaction 7 Communication Error

Boolean 0738 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

Page13 of 229 1/25/2013

Page 14: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1849 Peer to Peer Transaction 8 Communication Error

Boolean 0739 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1850 Peer to Peer Transaction 9 Communication Error

Boolean 073A R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1851 Peer to Peer Transaction 10 Communication Error

Boolean 073B R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1852 Peer to Peer Transaction 11 Communication Error

Boolean 073C R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1853 Peer to Peer Transaction 12 Communication Error

Boolean 073D R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1854 Peer to Peer Transaction 13 Communication Error

Boolean 073E R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1855 Peer to Peer Transaction 14 Communication Error

Boolean 073F R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1856 Peer to Peer Transaction 15 Communication Error

Boolean 0740 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1857 Peer to Peer Transaction 16 Communication Error

Boolean 0741 R If a slave is involved in multiple transactions which fail, only the first will be flagged.

  R, ‐, R R

1858 Day Start Flag (@ 00:00:00) for 500 mS Boolean 0742 R  R, ‐, R R1859 Week Start Flag (@ 00:00:00 Monday) Boolean 0743 R  R, ‐, R R1860 Month Start Flag (@ 00:00:00 1st Day of 

Month)Boolean 0744 R   R, ‐, R R

1861 Year Start Flag (@ 00:00:00 Jan.1st) Boolean 0745 R  R, ‐, R R1862 Station Density Transducer Failed to Low Boolean 0746 R   R, ‐, R R

1863 Station Density Low Alarm Boolean 0747 R  R, ‐, R R1864 Station Density High Alarm Boolean 0748 R  R, ‐, R R

Page14 of 229 1/25/2013

Page 15: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1865 Station Density Transducer Failed to High Boolean 0749 R   R, ‐, R R

1866 Station Density Temp Transducer Failed to Low

Boolean 074A R   R, ‐, R R

1867 Station Density Temperature Low Alarm Boolean 074B R  R, ‐, R R1868 Station Density Temperature High Alarm Boolean 074C R  R, ‐, R R1869 Station Density Temp Transducer Failed 

to HighBoolean 074D R   R, ‐, R R

1870 Station Density Pressure Transducer Failed to Low

Boolean 074E R   R, ‐, R R

1871 Station Density Pressure Low Alarm Boolean 074F R  R, ‐, R R1872 Station Density Pressure High Alarm Boolean 0750 R  R, ‐, R R1873 Station Density Pressure Transducer 

Failed to HighBoolean 0751 R   R, ‐, R R

1874 Viscosity Printed on Report Flag Boolean 0752 R  R, ‐, R R1875 Net Standard Volume Printed on Report 

FlagBoolean 0753 R   R, ‐, R R

1876 Re‐calculate Batch Flag (500 mS) Boolean 0754 R  R, ‐, R R1877 Print CTPL on Report Flag Boolean 0755 R  R, ‐, R R1878 Previous Batch Alarm Occurred Flag Boolean 0756 R  R, ‐, R R1879 Previous Batch Rollover Occurred Flag Boolean 0757 R  R, ‐, R R1880 Previous Daily Rollover Occurred Flag Boolean 0758 R  R, ‐, R R1882 Day End Flag (500mS) Boolean 075A R  R, ‐, R R1883 Auxiliary Input 1 Transducer Failed to 

LowBoolean 075B R   R, ‐, R R

1884 Auxiliary Input 1 Low Alarm Boolean 075C R  R, ‐, R R1885 Auxiliary Input 1 High Alarm Boolean 075D R  R, ‐, R R1886 Auxiliary Input 1 Transducer Failed to 

HighBoolean 075E R   R, ‐, R R

Page15 of 229 1/25/2013

Page 16: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1887 Auxiliary Input 2 Transducer Failed to Low

Boolean 075F R   R, ‐, R R

1888 Auxiliary Input 2 Low Alarm Boolean 0760 R  R, ‐, R R1889 Auxiliary Input 2 High Alarm Boolean 0761 R  R, ‐, R R1890 Auxiliary Input 2 Transducer Failed to 

HighBoolean 0762 R   R, ‐, R R

1891 Auxiliary Input 3 Transducer Failed to Low

Boolean 0763 R   R, ‐, R R

1892 Auxiliary Input 3 Low Alarm Boolean 0764 R  R, ‐, R R1893 Auxiliary Input 3 High Alarm Boolean 0765 R  R, ‐, R R1894 Auxiliary Input 3 Transducer Failed to 

LowBoolean 0766 R   R, ‐, R R

1895 Auxiliary Input 4 Transducer Failed to High

Boolean 0767 R   R, ‐, R R

1896 Auxiliary Input 4 Low Alarm Boolean 0768 R  R, ‐, R R1897 Auxiliary Input 4 High Alarm Boolean 0769 R  R, ‐, R R1898 Auxiliary Input 4 Transducer Failed to 

HighBoolean 076A R   R, ‐, R R

1899 Net Total @ 2nd Ref.T Printed on Report Flag

Boolean 076B R   R, ‐, R R

Prover booleans (2nd digit of index is 9 which defines as prover)

1901 Inlet Pressure Low Alarm Boolean 076D R Modbus register 1981 indicates the same status.   R, ‐, R R

1902 Inlet Pressure High Alarm Boolean 076E R Modbus register 1982 indicates the same status.   R, ‐, R R

1903 Outlet Pressure Low Alarm Boolean 076F R Modbus register 1985 indicates the same status.   R, ‐, R R

1904 Outlet Pressure High Alarm Boolean 0770 R Modbus register 1986 indicates the same status.   R, ‐, R R

Page16 of 229 1/25/2013

Page 17: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1905 Inlet Temperature Low Alarm Boolean 0771 R Modbus register 1989 indicates the same status.   R, ‐, R R

1906 Inlet Temperature High Alarm Boolean 0772 R Modbus register 1990 indicates the same status.   R, ‐, R R

1907 Outlet Temperature Low Alarm Boolean 0773 R Modbus register 1993 indicates the same status.   R, ‐, R R

1908 Outlet Temperature High Alarm Boolean 0774 R Modbus register 1994 indicates the same status.   R, ‐, R R

1909 Prover Temperature Unstable ‐ Prove Aborted

Boolean 0775 R   R, ‐, R R

1910 Temperature Deviation Between Pv & Meter Exceed

Boolean 0776 R   R, ‐, R R

1911 Prove Sequence Completed(Stay True Until Next Pv)

Boolean 0777 R   R, ‐, R R

1912 Prove Sequence Aborted ‐ Did Not Complete

Boolean 0778 R   R, ‐, R R

1913 Sphere in Flight Forward Direction Boolean 0779 R  R, ‐, R R1914 Sphere in Flight Reverse Direction Boolean 077A R  R, ‐, R R1915 Overtravel Forward Direction Boolean 077B R  R, ‐, R R1916 Overtravel Reverse Direction Boolean 077C R  R, ‐, R R1917 Launch Forward (2 Seconds Pulse) Boolean 077D R  R, ‐, R R1918 Launch Reverse (2 Seconds Pulse) Boolean 077E R  R, ‐, R R1919 Run Repeatability Deviation Limit 

ExceededBoolean 077F R   R, ‐, R R

1920 Prover Seal Not OK ‐ Prove Aborted Boolean 0780 R  R, ‐, R R1921 Flowrate Was Unstable ‐ Prove Aborted Boolean 0781 R  R, ‐, R R1922 No Prover Permissive ‐ Prove Aborted Boolean 0782 R  R, ‐, R R1923 Meter Factor Obtained Was Not 

ImplementedBoolean 0783 R   R, ‐, R R

1924 Proving Meter Was Not Active ‐ Prove Aborted

Boolean 0784 R   R, ‐, R R

Page17 of 229 1/25/2013

Page 18: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1925 Plenum Charge Required Boolean 0785 R  R, ‐, R R1926 Plenum Vent Required Boolean 0786 R  R, ‐, R R1927 Compact Prover Run Command Output Boolean 0787 R  R, ‐, R R1928 Prove Sequence Successfully Completed 

Flag (500mS)Boolean 0788 R   R, ‐, R R

1929 Inlet Temperature Override In Use Flag Boolean 0789 R  R, ‐, R R1930 Outlet Temperature Override In Use Flag Boolean 078A R   R, ‐, R R

1931 Inlet Pressure Override In Use Flag Boolean 078B R  R, ‐, R R1932 Outlet Pressure Override In Use Flag Boolean 078C R  R, ‐, R R

These flags are used to cause data to be condi onally printed on the prove report.

1933 Mass Prove Flag(Conditionally Printed Flag)

Boolean 078D R   R, ‐, R R

1934 Net Prove Flag (Conditionally Printed Flag)

Boolean 078E R   R, ‐, R R

1935 Mass Prove Report Flag (Conditionally Printed Flag)

Boolean 078F R   R, ‐, R R

1936 Net Prove Report Flag(Conditionally Printed Flag)

Boolean 0790 R   R, ‐, R R

1937 Prover Inactivity ‐ Prove Aborted Boolean 0791 R  R, ‐, R R1938 MF Repeatability In Use Flag(Printed Pv 

Rpt Flag)Boolean 0792 R   R, ‐, R R

1939 Count Repeatability In Use Flag(Printed Pv Rpt Flag)

Boolean 0793 R   R, ‐, R R

1940 Prover Density Transducer Failed to Low Boolean 0794 R   R, ‐, R R

1941 Prover Density Low Alarm Boolean 0795 R  R, ‐, R R1942 Prover Density High Alarm Boolean 0796 R  R, ‐, R R

Page18 of 229 1/25/2013

Page 19: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1943 Prover Density Transducer Failed to High Boolean 0797 R   R, ‐, R R

1944 Prover Density Temp Transducer Failed to Low

Boolean 0798 R   R, ‐, R R

1945 Prover Density Temp Low Alarm Boolean 0799 R  R, ‐, R R1946 Prover Density Temp High Alarm Boolean 079A R  R, ‐, R R1947 Prover Density Temp Transducer Failed to 

HighBoolean 079B R   R, ‐, R R

1948 Prover Density Pressure Transducer Failed to Low

Boolean 079C R   R, ‐, R R

1949 Prover Density Pressure Low Alarm Boolean 079D R  R, ‐, R R1950 Prover Density Pressure High Alarm Boolean 079E R  R, ‐, R R1951 Prover Density Pressure Transducer 

Failed to HighBoolean 079F R   R, ‐, R R

1952 Print Density on Mass Prove Report Flag Boolean 07A0 R   R, ‐, R R

1953 Print Cplp, Cplm on Volumetric Prove Report Flag

Boolean 07A1 R   R, ‐, R R

1954 Run Complete Flag (500mS) Boolean 07A2 R  R, ‐, R R1955 Viscosity Linearization Proving Mode Flag Boolean 07A3 R   R, ‐, R R

1956 Non‐Viscosity Linearization Proving Mode Flag

Boolean 07A4 R   R, ‐, R R

1957 Proving Meter API 11.1 2004 Flag Boolean 07A5 R  R, ‐, R R1958 Proving Meter Non‐API 11.1 2004 Flag Boolean 07A6 R  R, ‐, R R1959 Print 4 Decimal for Correction Factors on 

Pv RptBoolean 07A7 R   R, ‐, R R

Page19 of 229 1/25/2013

Page 20: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1960 Print 5 Decimal for Correction Factors on Pv Rpt

Boolean 07A8 R   R, ‐, R R

1961 Print 6 Decimal for Correction Factors on Pv Rpt

Boolean 07A9 R   R, ‐, R R

1962 Print 4 Decimal for Meter Factors on Pv Report

Boolean 07AA R   R, ‐, R R

1963 Print 5 Decimal for Meter Factors on Pv Report

Boolean 07AB R   R, ‐, R R

1964 Print 6 Decimal for Meter Factors on Pv Report

Boolean 07AC R   R, ‐, R R

1965 Print 5 Decimal for Intermediate Meter Factors

Boolean 07AD R   R, ‐, R R

1966 Print 6 Decimal for Intermediate Meter Factors

Boolean 07AE R   R, ‐, R R

1967 Print 7 Decimal for Intermediate Meter Factors

Boolean 07AF R   R, ‐, R R

1968 Print Run 1 on Prove Report Flag Boolean 07B0 R  R, ‐, R R1969 Print Run 2 on Prove Report Flag Boolean 07B1 R  R, ‐, R R1970 Print Run 3 on Prove Report Flag Boolean 07B2 R  R, ‐, R R1971 Print Run 4 on Prove Report Flag Boolean 07B3 R  R, ‐, R R1972 Print Run 5 on Prove Report Flag Boolean 07B4 R  R, ‐, R R1973 Print Run 6 on Prove Report Flag Boolean 07B5 R  R, ‐, R R1974 Print Run 7 on Prove Report Flag Boolean 07B6 R  R, ‐, R R1975 Print Run 8 on Prove Report Flag Boolean 07B7 R  R, ‐, R R1976 Print Run 9 on Prove Report Flag Boolean 07B8 R  R, ‐, R R1977 Print Run 10 on Prove Report Flag Boolean 07B9 R  R, ‐, R R1978 Printer Offline Alarm When Prove Passes 

are PrintingBoolean 07BA R   R, ‐,   R R

1980 Inlet Pressure Transducer Fail to Low Boolean 07BC R  R, ‐, R RPage20 of 229 1/25/2013

Page 21: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

1981 Inlet Pressure Low Alarm Boolean 07BD R  R, ‐, R R1982 Inlet Pressure High Alarm Boolean 07BE R  R, ‐, R R1983 Inlet Pressure Transducer Fail to High Boolean 07BF R  R, ‐, R R1984 Outlet Pressure Transducer Fail to Low Boolean 07C0 R  R, ‐, R R1985 Outlet Pressure Low Alarm Boolean 07C1 R  R, ‐, R R1986 Outlet Pressure High Alarm Boolean 07C2 R  R, ‐, R R1987 Outlet Pressure Transducer Fail to High Boolean 07C3 R   R, ‐, R R

1988 Inlet Temperature Transducer Fail to Low Boolean 07C4 R   R, ‐, R R

1989 Inlet Temperature Low Alarm Boolean 07C5 R  R, ‐, R R1990 Inlet Temperature High Alarm Boolean 07C6 R  R, ‐, R R1991 Inlet Temperature Transducer Fail to High Boolean 07C7 R   R, ‐, R R

1992 Outlet Temperature Transducer Fail to Low

Boolean 07C8 R   R, ‐, R R

1993 Outlet Temperature Low Alarm Boolean 07C9 R  R, ‐, R R1994 Outlet Temperature High Alarm Boolean 07CA R  R, ‐, R R1995 Outlet Temperature Transducer Fail to 

HighBoolean 07CB R   R, ‐, R R

1996 Print Abandoned Run 4 Flag Boolean 07CC R  R, ‐, R R1997 Print Abandoned Run 3 Flag Boolean 07CD R  R, ‐, R R1998 Print Abandoned Run 2 Flag Boolean 07CE R  R, ‐, R R1999 Print Abandoned Run 1 Flag Boolean 07CF R  R, ‐, R R

2101 Meter 1 Current Batch Gross Total Rollover Flag

Boolean 0835 R   R, ‐, R R

2102 Meter 1 Current Batch Net Total Rollover Flag

Boolean 0836 R   R, ‐, R R

2103 Meter 1 Current Batch Mass Total Rollover Flag

Boolean 0837 R   R, ‐, R R

Page21 of 229 1/25/2013

Page 22: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2104 Meter 1 Current Batch NSV Rollover Flag Boolean 0838 R   R, ‐, R R

2105 Meter 1 Current Cumulative Gross Rollover Flag

Boolean 0839 R   R, ‐, R R

2106 Meter 1 Current Cumulative Net Rollover Flag

Boolean 083A R   R, ‐, R R

2107 Meter 1 Current Cumulative Mass Rollover Flag

Boolean 083B R   R, ‐, R R

2108 Meter 1 Current Cumulative NSV Rollover Flag

Boolean 083C R   R, ‐, R R

2109 Meter 1 Daily Gross Total Rollover Flag Boolean 083D R   R, ‐, R R

2110 Meter 1 Daily Net Total Rollover Flag Boolean 083E R  R, ‐, R R2111 Meter 1 Daily Mass Total Rollover Flag Boolean 083F R  R, ‐, R R2112 Meter 1 Daily NSV Rollover Flag Boolean 0840 R  R, ‐, R R2113 Meter 1 Daily Cumulative Gross Rollover 

FlagBoolean 0841 R   R, ‐, R R

2114 Meter 1 Daily Cumulative Net Rollover Flag

Boolean 0842 R   R, ‐, R R

2115 Meter 1 Daily Cumulative Mass Rollover Flag

Boolean 0843 R   R, ‐, R R

2116 Meter 1 Daily Cumulative NSV Rollover Flag

Boolean 0844 R   R, ‐, R R

2117 Meter 1 Prev Batch 'n' Batch Gross Rollover Flag

Boolean 0845 R   R, ‐, R R

2118 Meter 1 Prev Batch 'n' Batch Net Rollover Flag

Boolean 0846 R   R, ‐, R R

Page22 of 229 1/25/2013

Page 23: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2119 Meter 1 Prev Batch 'n' Batch Mass Rollover Flag

Boolean 0847 R   R, ‐, R R

2120 Meter 1 Prev Batch 'n' Batch NSV Rollover Flag

Boolean 0848 R   R, ‐, R R

2121 Meter 1 Prev Batch 'n' Cum Gross Rollover Flag

Boolean 0849 R   R, ‐, R R

2122 Meter 1 Prev Batch 'n' Cum Net Rollover Flag

Boolean 084A R   R, ‐, R R

2123 Meter 1 Prev Batch 'n' Cum Mass Rollover Flag

Boolean 084B R   R, ‐, R R

2124 Meter 1 Prev Batch 'n' Cum NSV Rollover flag

Boolean 084C R   R, ‐, R R

2125 Meter 1 Prev Daily Gross Total Rollover Flag

Boolean 084D R   R, ‐, R R

2126 Meter 1 Prev Daily Net Total Rollover Flag Boolean 084E R   R, ‐, R R

2127 Meter 1 Prev Daily Mass Total Rollover Flag

Boolean 084F R   R, ‐, R R

2128 Meter 1 Prev Daily NSV Rollover Flag Boolean 0850 R  R, ‐, R R2129 Meter 1 Prev Daily Cum Gross Rollover 

FlagBoolean 0851 R   R, ‐, R R

2130 Meter 1 Prev Daily Cum Net Rollover Flag Boolean 0852 R   R, ‐, R R

2131 Meter 1 Prev Daily Cum Mass Rollover Flag

Boolean 0853 R   R, ‐, R R

Page23 of 229 1/25/2013

Page 24: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2132 Meter 1 Prev Daily Cum NSV Rollover Flag Boolean 0854 R   R, ‐, R R

2133 Meter 1 Current Batch 2nd Net Total Rollover Flag

Boolean 0855 R   R, ‐, R R

2134 Meter 1 Current Daily 2nd Net Total Rollover Flag

Boolean 0856 R   R, ‐, R R

2135 Meter 1 Prev Batch 'n' 2nd Net Rollover Flag

Boolean 0857 R   R, ‐, R R

2136 Meter 1 Prev Daily 2nd Net Total Rollover Flag

Boolean 0858 R   R, ‐, R R

2137 Meter 1 Product in Use BCD Bit 0 Boolean 0859 R  R, ‐, R R2138 Meter 1 Product in Use BCD Bit 1 Boolean 085A R  R, ‐, R R2139 Meter 1 Product in Use BCD Bit 2 Boolean 085B R  R, ‐, R R2140 Meter 1 Product in Use BCD Bit 3 Boolean 085C R  R, ‐, R R2141 Meter 1 Non‐Ammonia Flag Boolean 085D R  R, ‐, R R2142 Meter 1 Ammonia Flag Boolean 085E R  R, ‐, R R2150 Meter 1 Previous Batch Use CTPL Flag Boolean 0866 R  R, ‐, R R2192 Meter 1 Gross Increment Exceed Limits Boolean 0890 R  R, ‐, R R2193 Meter 1 Net Increment Exceed Limits Boolean 0891 R  R, ‐, R R2194 Meter 1 Mass Increment Exceed Limits Boolean 0892 R  R, ‐, R R2195 Meter 1 NSV Increment Exceed Limits Boolean 0893 R  R, ‐, R R2199 Reserved

2201 ‐ 2299 Meter 2 (Same as 2101 ‐ 2199) Boolean 0899 R  R, ‐, R R2301 ‐ 2399 Meter 3 (Same as 2101 ‐ 2199) Boolean 08FD R  R, ‐, R R2401 ‐ 2499 Meter 4 (Same as 2101 ‐ 2199) Boolean 0961 R  R, ‐, R R

2601 Auxiliary Input 1 Override in Use Flag Boolean 0A29 R  R, ‐, R R2602 Auxiliary Input 2 Override in Use Flag Boolean 0A2A R  R, ‐, R R2603 Auxiliary Input 3 Override in Use Flag Boolean 0A2B R  R, ‐, R R2604 Auxiliary Input 4 Override in Use Flag Boolean 0A2C R  R, ‐, R R2605 Inlet Temperature Override in Use Flag Boolean 0A2D R  R, ‐, R R

Page24 of 229 1/25/2013

Page 25: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2606 Outlet Temperature Override in Use Flag Boolean 0A2E R   R, ‐, R R

2607 Inlet Pressure Override in Use Flag Boolean 0A2F R  R, ‐, R R2608 Outlet Pressure Override in Use Flag Boolean 0A30 R  R, ‐, R R2609 Switch Bar Temperature Override in Use 

FlagBoolean 0A31 R   R, ‐, R R

2610 Switch Bar Temperature Fail Low Boolean 0A32 R  R, ‐, R R2611 Swithc Bar Temperature Low Alarm Boolean 0A33 R  R, ‐, R R2612 Switch Bar Temperature High Alarm Boolean 0A34 R  R, ‐, R R2613 Switch Bar Temperature Fail High Boolean 0A35 R  R, ‐, R R2614 Reserved2615 Reserved2616 Reserved2617 Reserved2618 Reserved2619 Reserved2620 Calibration Data Checksum Error Boolean 0A3C R  R, ‐, R R2621 System Initialized Flag Boolean 0A3D R  R, ‐, R R2622 Day Light Savings Time Boolean 0A3E R  R, ‐, R R2623 Archive Memory Alarm (0=OK, 1=Alarm) Boolean 0A3F R  R, R, R R2630 Reserved2631 Serial 1 as Ethernet Port (0=No, 1=Yes) Boolean 0A47 R   R, ‐, R R

2632 Serial 2 as Ethernet Port (0=No, 1=Yes) Boolean 0A48 R   R, ‐, R R

2633 Serial 3 as Ethernet Port (0=No, 1=Yes) Boolean 0A49 R   R, ‐, R R

2634 Serial 4 as Ethernet Port (0=No, 1=Yes) Boolean 0A4A R   R, ‐, R R

2635 Serial 5 as Ethernet Port (0=No, 1=Yes) Boolean 0A4B R   R, ‐, R R

2636 Serial 6 as Ethernet Port (0=No, 1=Yes) Boolean 0A4C R   R, ‐, R R

2637 SE‐1 Ethernet Mode (0=V0, 1=V2) Boolean 0A4D R  R, ‐, R R2638 SE‐2 Ethernet Mode (0=V0, 1=V2) Boolean 0A4E R  R, ‐, R R2639 SE‐3 Ethernet Mode (0=V0, 1=V2) Boolean 0A4F R  R, ‐, R R2640 SE‐1 Ethernet Printer 1 Error Boolean 0A50 R  R, ‐, R R

Page25 of 229 1/25/2013

Page 26: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2641 SE‐1 Ethernet Printer 2 Error Boolean 0A51 R  R, ‐, R R2642 ‐ 2645 Reserved2646 SE‐2 Ethernet Printer 1 Error Boolean 0A56 R  R, ‐, R R2647 SE‐2 Ethernet Printer 2 Error Boolean 0A57 R  R, ‐, R R2648 ‐ 2651 Reserved2652 SE‐3 Ethernet Printer 1 Error Boolean 0A5C R  R, ‐, R R2653 SE‐3 Ethernet Printer 2 Error Boolean 0A5D R  R, ‐, R R2654 ‐ 2657 Reserved2658 SE‐1 Ethernet Link Down Boolean 0A62 R  R, ‐, R R2659 SE‐2 Ethernet Link Down Boolean 0A63 R  R, ‐, R R2660 SE‐3 Ethernet Link Down Boolean 0A64 R  R, ‐, R R2661 Station HART device type mismatch the 

Density Temp assignmentBoolean 0A65 R   R, ‐, R R

2662 Station HART device type mismatch the Density Pressure assignment

Boolean 0A66 R   R, ‐, R R

2663 HART device type mismatch the Inlet Temperature assignment

Boolean 0A67 R   R, ‐, R R

2664 HART device type mismatch the Outlet Temperature assignment

Boolean 0A68 R   R, ‐, R R

2665 HART device type mismatch the Inlet Pressure assignment

Boolean 0A69 R   R, ‐, R R

2666 HART device type mismatch the Outlet Pressure assignment

Boolean 0A6A R   R, ‐, R R

2667 HART device type mismatch the Pv Density Temperature assignment

Boolean 0A6B R   R, ‐, R R

2668 HART device type mismatch the Pv Density Pressure assignment

Boolean 0A6C R   R, ‐, R R

2669 HART device type mismatch the Switch Bar Temperature assignment

Boolean 0A6D R   R, ‐, R R

Page26 of 229 1/25/2013

Page 27: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2670 HART device type mismatch the Plenum Pressure assignment

Boolean 0A6E R   R, ‐, R R

2671 Station Density Temperature HART device lost communication alarm

Boolean 0A6F R   R, ‐, R R

2672 Station Density Pressure HART device lost communication alarm

Boolean 0A70 R   R, ‐, R R

2673 Inlet Temperature HART device lost communication alarm

Boolean 0A71 R   R, ‐, R R

2674 Outlet Temperature HART device lost communication alarm

Boolean 0A72 R   R, ‐, R R

2675 Inlet Pressure HART device lost communication alarm

Boolean 0A73 R   R, ‐, R R

2676 Outlet Pressure HART device lost communication alarm

Boolean 0A74 R   R, ‐, R R

2677 Pv Density Temperature HART device lost communication alarm

Boolean 0A75 R   R, ‐, R R

2678 Pv Density Pressure HART device lost communication alarm

Boolean 0A76 R   R, ‐, R R

2679 Switch Bar Temperature HART device lost communication alarm

Boolean 0A77 R   R, ‐, R R

2680 Plenum Pressure HART device lost communication alarm

Boolean 0A78 R   R, ‐, R R

2681 ‐ 2699 Reserved

The following are command booleans which cause some action to occur.Most are edge triggered and reset automatically after the action occurs, ie: You set them and forget about them.

Page27 of 229 1/25/2013

Page 28: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2701 Data Packet 1 to Serial Port 1 Boolean 0A8D R/W R/W, ‐, R R2702 Data Packet 2 to Serial Port 1 Boolean 0A8E R/W R/W, ‐, R R2703 Data Packet 3 to Serial Port 1 Boolean 0A8F R/W R/W, ‐, R R2704 Data Packet 1 to Serial Port 2 Boolean 0A90 R/W R/W, ‐, R R2705 Data Packet 2 to Serial Port 2 Boolean 0A91 R/W R/W, ‐, R R2706 Data Packet 3 to Serial Port 2 Boolean 0A92 R/W R/W, ‐, R R2707 Data Packet 1 to Serial Port 3 Boolean 0A93 R/W R/W, ‐, R R2708 Data Packet 2 to Serial Port 3 Boolean 0A94 R/W R/W, ‐, R R2709 Data Packet 3 to Serial Port 3 Boolean 0A95 R/W R/W, ‐, R R2710 Data Packet 1 to Serial Port 4 Boolean 0A96 R/W R/W, ‐, R R2711 Data Packet 2 to Serial Port 4 Boolean 0A97 R/W R/W, ‐, R R2712 Data Packet 3 to Serial Port 4 Boolean 0A98 R/W R/W, ‐, R R2713 Other Watchdog Status (Redundancy 

Mode)Boolean 0A99 R/W R/W, ‐, R R

2714 Other Master Status (Redundancy Mode) Boolean 0A9A R/W R/W, ‐, R R

2715 Assume Master Status Command (Redundancy Mode)

Boolean 0A9B R/W R/W, ‐, R R

2716 Assume Slave Status Command(Redundancy Mode)

Boolean 0A9C R/W R/W, ‐, R R

2729 ‐ 2732 Reserved2741 Force Day End Meter 1 Boolean 0AB5 R/W R/W, ‐, R Y R2742 Force Day End Meter 2 Boolean 0AB6 R/W R/W, ‐, R Y R2743 Force Day End Meter 3 Boolean 0AB7 R/W R/W, ‐, R Y R2744 Force Day End Meter 4 Boolean 0AB8 R/W R/W, ‐, R Y R2745 Force Day End Station Boolean 0AB9 R/W R/W, ‐, R Y R2746 Remote Request to Print Audit Report Boolean 0ABA R/W R/W, ‐, R R2747 Force Discovery Mode (Set From 

OmniCom)Boolean 0ABB R/W R/W, ‐, R R

2747 ‐ 2750 Reserved2751 End Batch Meter 1 ‐ No Stack Operation Boolean 0ABF R/W R/W, W, R Y R2752 End Batch Meter 2 ‐ No Stack Operation Boolean 0AC0 R/W R/W, W, R Y R2753 End Batch Meter 3 ‐ No Stack Operation Boolean 0AC1 R/W R/W, W, R Y R2754 End Batch Meter 4 ‐ No Stack Operation Boolean 0AC2 R/W R/W, W, R Y R

Page28 of 229 1/25/2013

Page 29: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2755 End Batch Station ‐ No Stack Operation Boolean 0AC3 R/W R/W, W, R Y R2756 Recalculate and Print Selected Batch ‐ 

Meter 1Boolean 0AC4 R/W R/W, ‐, R Y R

2757 Recalculate and Print Selected Batch ‐ Meter 2

Boolean 0AC5 R/W R/W, ‐, R Y R

2758 Recalculate and Print Selected Batch ‐ Meter 3

Boolean 0AC6 R/W R/W, ‐, R Y R

2759 Recalculate and Print Selected Batch ‐ Meter 4

Boolean 0AC7 R/W R/W, ‐, R Y R

2760 Serial 1 Has Ethernet Printers(0=No, 1=Yes)

Boolean 0AC8 R/W  R/W, ‐, R R

2761 Reserved2762 Serial 2 Has Ethernet Printers(0=No, 

1=Yes)Boolean 0ACA R/W  R/W, ‐, R R

2763 Reserved2764 Serial 3 Has Ethernet Printers(0=No, 

1=Yes)Boolean 0ACC R/W  R/W, ‐, R R

2765 Reserved2766 Serial 4 Has Ethernet Printers(0=No, 

1=Yes)Boolean 0ACE R/W  R/W, ‐, R R

2767 Reserved2768 Serial 5 Has Ethernet Printers(0=No, 

1=Yes)Boolean 0AD0 R/W  R/W, ‐, R R

2769 Reserved2770 Serial 6 Has Ethernet Printers(0=No, 

1=Yes)Boolean 0AD2 R/W  R/W, ‐, R R

2771 ‐ 2774 Reserved

Page29 of 229 1/25/2013

Page 30: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2775 SE‐1 Ethernet Set Configuration Status Command

Boolean 0AD7 R/W  R/W, ‐, R R

2776 SE‐2 Ethernet Set Configuration Status Command

Boolean 0AD8 R/W  R/W, ‐, R R

2777 SE‐3 Ethernet Set Configuration Status Command

Boolean 0AD9 R/W  R/W, ‐, R R

2778 ‐ 2799 Reserved

2801 Station Current Batch Gross Total Rollover Flag

Boolean 0AF1 R   R, ‐, R R

2802 Station Current Batch Net Total Rollover Flag

Boolean 0AF2 R   R, ‐, R R

2803 Station Current Batch Mass Total Rollover Flag

Boolean 0AF3 R   R, ‐, R R

2804 Station Current Batch Net Standard Total Rollover Flag

Boolean 0AF4 R   R, ‐, R R

2805 Station Current Batch Cum Gross Rollover Flag

Boolean 0AF5 R   R, ‐, R R

2806 Station Current Batch Cum Net Rollover Flag

Boolean 0AF6 R   R, ‐, R R

2807 Station Current Batch Cum Mass Rollover Flag

Boolean 0AF7 R   R, ‐, R R

2808 Station Current Batch Cum NSV Rollover Flag

Boolean 0AF8 R   R, ‐, R R

2809 Station Daily Gross Total Rollover Flag Boolean 0AF9 R   R, ‐, R R

2810 Station Daily Net Total Rollover Flag Boolean 0AFA R  R, ‐, R RPage30 of 229 1/25/2013

Page 31: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2811 Station Daily Mass Total Rollover Flag Boolean 0AFB R  R, ‐, R R2812 Station Daily Net Standard Total Rollover 

FlagBoolean 0AFC R   R, ‐, R R

2813 Station Daily Cumulative Gross Rollover Flag

Boolean 0AFD R   R, ‐, R R

2814 Station Daily Cumulative Net Rollover Flag

Boolean 0AFE R   R, ‐, R R

2815 Station Daily Cumulative Mass Rollover Flag

Boolean 0AFF R   R, ‐, R R

2816 Station Daily Cumulative NSV Rollover Flag

Boolean 0B00 R   R, ‐, R R

2817 Station Prev Batch 'n' Batch Gross Rollover Flag

Boolean 0B01 R   R, ‐, R R

2818 Station Prev Batch 'n' Batch Net Rollover Flag

Boolean 0B02 R   R, ‐, R R

2819 Station Prev Batch 'n' Batch Mass Rollover Flag

Boolean 0B03 R   R, ‐, R R

2820 Station Prev Batch 'n' Batch NSV Rollover Flag

Boolean 0B04 R   R, ‐, R R

2821 Station Previous Batch 'n' Cum Gross Rollover Flag

Boolean 0B05 R   R, ‐, R R

2822 Station Previous Batch 'n' Cum Net Rollover Flag

Boolean 0B06 R   R, ‐, R R

2823 Station Previous Batch 'n' Cum Mass Rollover Flag

Boolean 0B07 R   R, ‐, R R

Page31 of 229 1/25/2013

Page 32: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2824 Station Previous Batch 'n' Cum NSV Rollover Flag

Boolean 0B08 R   R, ‐, R R

2825 Station Previous Daily Gross Rollover Flag Boolean 0B09 R   R, ‐, R R

2826 Station Previous Daily Net Rollover Flag Boolean 0B0A R   R, ‐, R R

2827 Station Previous Daily Mass Rollover Flag Boolean 0B0B R   R, ‐, R R

2828 Station Previous Daily Net Standard Rollover Flag

Boolean 0B0C R   R, ‐, R R

2829 Station Previous Day Cum Gross Rollover Flag

Boolean 0B0D R   R, ‐, R R

2830 Station Previous Day Cumulative Net Rollover Flag

Boolean 0B0E R   R, ‐, R R

2831 Station Previous Day Cum Mass Rollover Flag

Boolean 0B0F R   R, ‐, R R

2832 Station Previous Day Cum NSV Rollover Flag

Boolean 0B10 R   R, ‐, R R

2833 Station Current Batch 2nd Net Total Rollover Flag

Boolean 0B11 R   R, ‐, R R

2834 Station Current Daily 2nd Net Total Rollover Flag

Boolean 0B12 R   R, ‐, R R

2835 Station Previous Batch 'n' 2nd Net Rollover Flag

Boolean 0B13 R   R, ‐, R R

2836 Station Previous Day 2nd Net Rollover Flag

Boolean 0B14 R   R, ‐, R R

Page32 of 229 1/25/2013

Page 33: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2840 Flash Jumper in Enable Position Boolean 0B18 R  R, ‐,  R R2841 Non‐Ammonia Format Report Flag Boolean 0B19 R  R, ‐, R R2842 Ammonia Format Report Flag Boolean 0B1A R  R, ‐, R R2843 Auxiliary Input 1 HART Device Lost 

Communication AlarmBoolean 0B1B R   R, ‐, R R

2844 Auxiliary Input 2 HART Device Lost Communication Alarm

Boolean 0B1C R   R, ‐, R R

2845 Auxiliary Input 3 HART Device Lost Communication Alarm

Boolean 0B1D R   R, ‐, R R

2846 Auxiliary Input 4 HART Device Lost Communication Alarm

Boolean 0B1E R   R, ‐, R R

2852 Print 4 Decimal for Correction Factors Batch Rpt

Boolean 0B24 R   R, ‐, R R

2853 Print 5 Decimal for Correction Factors Batch Rpt

Boolean 0B25 R   R, ‐, R R

2854 Print 6 Decimal for Correction Factors Batch Rpt

Boolean 0B26 R   R, ‐, R R

2855 Print 4 Decimal for Meter Factor on Batch Report

Boolean 0B27 R   R, ‐, R R

2856 Print 5 Decimal for Meter Factor on Batch Report

Boolean 0B28 R   R, ‐, R R

2857 Print 6 Decimal for Meter Factor on Batch Report

Boolean 0B29 R   R, ‐, R R

2858 Print 0 Decimal Place for Gross & Net Totalizer

Boolean 0B2A R   R, ‐, R R

Page33 of 229 1/25/2013

Page 34: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

2859 Print 1 Decimal Place for Gross & Net Totalizer

Boolean 0B2B R   R, ‐, R R

2860 Print 2 Decimal Places for Gross & Net Totalizer

Boolean 0B2C R   R, ‐, R R

2861 Print 3 Decimal Places for Gross & Net Totalizer

Boolean 0B2D R   R, ‐, R R

2862 Reserved2863 Watchdog Status (Redundancy Mode) Boolean 0B2F R  R, ‐, R R2864 Master Status (Redundancy Mode) Boolean 0B30 R  R, ‐, R R2865 Print 0 Decimal Place for Mass Totalizer Boolean 0B31 R   R, ‐, R R

2866 Print 1 Decimal Place for Mass Totalizer Boolean 0B32 R   R, ‐, R R

2867 Print 2 Decimal Places for Mass Totalizer Boolean 0B33 R   R, ‐, R R

2868 Print 3 Decimal Places for Mass Totalizer Boolean 0B34 R   R, ‐, R R

2897 ‐ 2899 Reserved

These indexs define the 16‐bit integer contents of the 'Custom Data Packet'

3001 Packet 1 Starting Index 1 UINT‐16 0BB9 R/W R/W, ‐, R N R3002 Packet 1 Number of Index Points 1 UINT‐16 0BBA R/W R/W, ‐, R N R3003 Packet 1 Starting Index 2 UINT‐16 0BBB R/W R/W, ‐, R N R3004 Packet 1 Number of Index Points 2 UINT‐16 0BBC R/W R/W, ‐, R N R3005 Packet 1 Starting Index 3 UINT‐16 0BBD R/W R/W, ‐, R N R3006 Packet 1 Number of Index Points 3 UINT‐16 0BBE R/W R/W, ‐, R N R3007 Packet 1 Starting Index 4 UINT‐16 0BBF R/W R/W, ‐, R N R3008 Packet 1 Number of Index Points 4 UINT‐16 0BC0 R/W R/W, ‐, R N R3009 Packet 1 Starting Index 5 UINT‐16 0BC1 R/W R/W, ‐, R N R3010 Packet 1 Number of Index Points 5 UINT‐16 0BC2 R/W R/W, ‐, R N R

Page34 of 229 1/25/2013

Page 35: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3011 Packet 1 Starting Index 6 UINT‐16 0BC3 R/W R/W, ‐, R N R3012 Packet 1 Number of Index Points 6 UINT‐16 0BC4 R/W R/W, ‐, R N R3013 Packet 1 Starting Index 7 UINT‐16 0BC5 R/W R/W, ‐, R N R3014 Packet 1 Number of Index Points 7 UINT‐16 0BC6 R/W R/W, ‐, R N R3015 Packet 1 Starting Index 8 UINT‐16 0BC7 R/W R/W, ‐, R N R3016 Packet 1 Number of Index Points 8 UINT‐16 0BC8 R/W R/W, ‐, R N R3017 Packet 1 Starting Index 9 UINT‐16 0BC9 R/W R/W, ‐, R N R3018 Packet 1 Number of Index Points 9 UINT‐16 0BCA R/W R/W, ‐, R N R3019 Packet 1 Starting Index 10 UINT‐16 0BCB R/W R/W, ‐, R N R3020 Packet 1 Number of Index Points 10 UINT‐16 0BCC R/W R/W, ‐, R N R3021 Packet 1 Starting Index 11 UINT‐16 0BCD R/W R/W, ‐, R N R3022 Packet 1 Number of Index Points 11 UINT‐16 0BCE R/W R/W, ‐, R N R3023 Packet 1 Starting Index 12 UINT‐16 0BCF R/W R/W, ‐, R N R3024 Packet 1 Number of Index Points 12 UINT‐16 0BD0 R/W R/W, ‐, R N R3025 Packet 1 Starting Index 13 UINT‐16 0BD1 R/W R/W, ‐, R N R3026 Packet 1 Number of Index Points 13 UINT‐16 0BD2 R/W R/W, ‐, R N R3027 Packet 1 Starting Index 14 UINT‐16 0BD3 R/W R/W, ‐, R N R3028 Packet 1 Number of Index Points 14 UINT‐16 0BD4 R/W R/W, ‐, R N R3029 Packet 1 Starting Index 15 UINT‐16 0BD5 R/W R/W, ‐, R N R3030 Packet 1 Number of Index Points 15 UINT‐16 0BD6 R/W R/W, ‐, R N R3031 Packet 1 Starting Index 16 UINT‐16 0BD7 R/W R/W, ‐, R N R3032 Packet 1 Number of Index Points 16 UINT‐16 0BD8 R/W R/W, ‐, R N R3033 Packet 1 Starting Index 17 UINT‐16 0BD9 R/W R/W, ‐, R N R3034 Packet 1 Number of Index Points 17 UINT‐16 0BDA R/W R/W, ‐, R N R3035 Packet 1 Starting Index 18 UINT‐16 0BDB R/W R/W, ‐, R N R3036 Packet 1 Number of Index Points 18 UINT‐16 0BDC R/W R/W, ‐, R N R3037 Packet 1 Starting Index 19 UINT‐16 0BDD R/W R/W, ‐, R N R3038 Packet 1 Number of Index Points 19 UINT‐16 0BDE R/W R/W, ‐, R N R3039 Packet 1 Starting Index 20 UINT‐16 0BDF R/W R/W, ‐, R N R3040 Packet 1 Number of Index Points 20 UINT‐16 0BE0 R/W R/W, ‐, R N R3041 Packet 2 Starting Index 1 UINT‐16 0BE1 R/W R/W, ‐, R N R3042 Packet 2 Number of Index Pts UINT‐16 0BE2 R/W R/W, ‐, R N R3043 Packet 2 Starting Index 2 UINT‐16 0BE3 R/W R/W, ‐, R N R3044 Packet 2 Number of Index Pts UINT‐16 0BE4 R/W R/W, ‐, R N R3045 Packet 2 Starting Index 3 UINT‐16 0BE5 R/W R/W, ‐, R N R3046 Packet 2 Number of Index Pts UINT‐16 0BE6 R/W R/W, ‐, R N R3047 Packet 2 Starting Index 4 UINT‐16 0BE7 R/W R/W, ‐, R N R3048 Packet 2 Number of Index Pts UINT‐16 0BE8 R/W R/W, ‐, R N R

Page35 of 229 1/25/2013

Page 36: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3049 Packet 2 Starting Index 5 UINT‐16 0BE9 R/W R/W, ‐, R N R3050 Packet 2 Number of Index Pts UINT‐16 0BEA R/W R/W, ‐, R N R3051 Packet 2 Starting Index 6 UINT‐16 0BEB R/W R/W, ‐, R N R3052 Packet 2 Number of Index Pts UINT‐16 0BEC R/W R/W, ‐, R N R3053 Packet 2 Starting Index 7 UINT‐16 0BED R/W R/W, ‐, R N R3054 Packet 2 Number of Index Pts UINT‐16 0BEE R/W R/W, ‐, R N R3055 Packet 2 Starting Index 8 UINT‐16 0BEF R/W R/W, ‐, R N R3056 Packet 2 Number of Index Pts UINT‐16 0BF0 R/W R/W, ‐, R N R3057 Packet 3 Starting Index 1 UINT‐16 0BF1 R/W R/W, ‐, R N R3058 Packet 3 Number of Index Pts UINT‐16 0BF2 R/W R/W, ‐, R N R3059 Packet 3 Starting Index 2 UINT‐16 0BF3 R/W R/W, ‐, R N R3060 Packet 3 Number of Index Pts UINT‐16 0BF4 R/W R/W, ‐, R N R3061 Packet 3 Starting Index 3 UINT‐16 0BF5 R/W R/W, ‐, R N R3062 Packet 3 Number of Index Pts UINT‐16 0BF6 R/W R/W, ‐, R N R3063 Packet 3 Starting Index 4 UINT‐16 0BF7 R/W R/W, ‐, R N R3064 Packet 3 Number of Index Pts UINT‐16 0BF8 R/W R/W, ‐, R N R3065 Packet 3 Starting Index 5 UINT‐16 0BF9 R/W R/W, ‐, R N R3066 Packet 3 Number of Index Pts UINT‐16 0BFA R/W R/W, ‐, R N R3067 Packet 3 Starting Index 6 UINT‐16 0BFB R/W R/W, ‐, R N R3068 Packet 3 Number of Index Pts UINT‐16 0BFC R/W R/W, ‐, R N R3069 Packet 3 Starting Index 7 UINT‐16 0BFD R/W R/W, ‐, R N R3070 Packet 3 Number of Index Pts UINT‐16 0BFE R/W R/W, ‐, R N R3071 Packet 3 Starting Index 8 UINT‐16 0BFF R/W R/W, ‐, R N R3072 Packet 3 Number of Index Pts UINT‐16 0C00 R/W R/W, ‐, R N R3073 Packet 3 Starting Index 9 UINT‐16 0C01 R/W R/W, ‐, R N R3074 Packet 3 Number of Index Pts UINT‐16 0C02 R/W R/W, ‐, R N R3075 Packet 3 Starting Index 10 UINT‐16 0C03 R/W R/W, ‐, R N R3076 Packet 3 Number of Index Pts UINT‐16 0C04 R/W R/W, ‐, R N R3077 Packet 3 Starting Index 11 UINT‐16 0C05 R/W R/W, ‐, R N R3078 Packet 3 Number of Index Pts UINT‐16 0C06 R/W R/W, ‐, R N R3079 Packet 3 Starting Index 12 UINT‐16 0C07 R/W R/W, ‐, R N R3080 Packet 3 Number of Index Pts UINT‐16 0C08 R/W R/W, ‐, R N R3081 Packet 3 Starting Index 13 UINT‐16 0C09 R/W R/W, ‐, R N R3082 Packet 3 Number of Index Pts UINT‐16 0C0A R/W R/W, ‐, R N R3083 Packet 3 Starting Index 14 UINT‐16 0C0B R/W R/W, ‐, R N R3084 Packet 3 Number of Index Pts UINT‐16 0C0C R/W R/W, ‐, R N R3085 Packet 3 Starting Index 15 UINT‐16 0C0D R/W R/W, ‐, R N R3086 Packet 3 Number of Index Pts UINT‐16 0C0E R/W R/W, ‐, R N R

Page36 of 229 1/25/2013

Page 37: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3087 Packet 3 Starting Index 16 UINT‐16 0C0F R/W R/W, ‐, R N R3088 Packet 3 Number of Index Pts UINT‐16 0C10 R/W R/W, ‐, R N R3089 Packet 3 Starting Index 17 UINT‐16 0C11 R/W R/W, ‐, R N R3090 Packet 3 Number of Index Pts UINT‐16 0C12 R/W R/W, ‐, R N R3091 Packet 3 Starting Index 18 UINT‐16 0C13 R/W R/W, ‐, R N R3092 Packet 3 Number of Index Pts UINT‐16 0C14 R/W R/W, ‐, R N R3093 Packet 3 Starting Index 19 UINT‐16 0C15 R/W R/W, ‐, R N R3094 Packet 3 Number of Index Pts UINT‐16 0C16 R/W R/W, ‐, R N R3095 Packet 3 Starting Index 20 UINT‐16 0C17 R/W R/W, ‐, R N R3096 Packet 3 Number of Index Pts UINT‐16 0C18 R/W R/W, ‐, R N R3097 Alarm Timer ( 0 ‐ 128 Seconds) UINT‐16 0C19 R/W R/W, ‐, R Y R3098 Digits of Totalizer (0=9, 1=8) UINT‐16 0C1A R/W R/W, ‐, R N R3099 Select Batch Preset 

Unit(0=Net,1=Gross,2=Mass)UINT‐16 0C1B R/W  R/W, R, R N R

16 Bit Integer Data.

3101 Meter 1 Temperature Override Code UINT‐16 0C1D R/W R/W, ‐, R Y R3102 Meter 1 Pressure Override Code UINT‐16 0C1E R/W R/W, ‐, R Y R3103 Meter 1 Gravity/Density Override Code UINT‐16 0C1F R/W R/W, ‐, R Y R3104 Meter 1 Density Temperature Override 

CodeUINT‐16 0C20 R/W  R/W, ‐, R Y R

3105 Meter 1 Density Pressure Override Code UINT‐16 0C21 R/W R/W, ‐, R Y R3106 Meter 1 Flowmeter Active Threshold Hz UINT‐16 0C22 R/W R/W, ‐, R N R3107 Meter 1 Prover Volume Select UINT‐16 0C23 R/W For Brooks small volume prover, 

0=use downstream prove volume 1=use upstream prove volume

 R/W, ‐, R N R

3108 Meter 1 Auto Prove Enable (0=No, 1=Yes) UINT‐16 0C24 R/W  R/W, ‐, R Y R

3110 Meter 1 LCF used in Gross(IV), 0=No, 1=Yes

UINT‐16 0C26 R/W  R/W, ‐, R N R

3113 Meter 1 MF used in Net/Mass (0=No, 1=Yes)

UINT‐16 0C29 R/W  R/W, ‐, R N R

Page37 of 229 1/25/2013

Page 38: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3114 Meter 1 Temperature Compensated (0=No,1=Yes)

UINT‐16 0C2A R/W  R/W, ‐, R N R

3115 Meter 1 Select 0=PD Meter,1=Helical Turbine

UINT‐16 0C2B R/W  R/W, ‐, R N R

3116 Meter 1 Use Auxiliary Input 'n' as %S&W UINT‐16 0C2C R/W  R/W, ‐, R N R

3117 Meter 1 Use Auxiliary Input 'n' as Viscosity

UINT‐16 0C2D R/W  R/W, ‐, R N R

3118 Meter 1 Micro Motion Alarm Word UINT‐16 0C2E R  R, ‐, R3119 Meter 1 Valve Mode. 1=Manual 0=Auto UINT‐16 0C2F R/W R/W, ‐, R Y R3120 Meter 1 Setpoint Mode 1=Local 

0=Remote(Read Only)UINT‐16 0C30 R/W  R/W, ‐, R Y R

3121 Meter 1 PID Loop in Control, 1=Sec. 0=Primary

UINT‐16 0C31 R   R, ‐, R

3122 Meter 1 K Factor 1 Frequency Point UINT‐16 0C32 R/W R/W, ‐, R N R3123 Meter 1 K Factor 2 Frequency Point UINT‐16 0C33 R/W R/W, ‐, R N R3124 Meter 1 K Factor 3 Frequency Point UINT‐16 0C34 R/W R/W, ‐, R N R3125 Meter 1 K Factor 4 Frequency Point UINT‐16 0C35 R/W R/W, ‐, R N R3126 Meter 1 K Factor 5 Frequency Point UINT‐16 0C36 R/W R/W, ‐, R N R3127 Meter 1 K Factor 6 Frequency Point UINT‐16 0C37 R/W R/W, ‐, R N R3128 Meter 1 K Factor 7 Frequency Point UINT‐16 0C38 R/W R/W, ‐, R N R3129 Meter 1 K Factor 8 Frequency Point UINT‐16 0C39 R/W R/W, ‐, R N R3130 Meter 1 K Factor 9 Frequency Point UINT‐16 0C3A R/W R/W, ‐, R N R3131 Meter 1 K Factor 10 Frequency Point UINT‐16 0C3B R/W R/W, ‐, R N R3132 Meter 1 K Factor 11 Frequency Point UINT‐16 0C3C R/W R/W, ‐, R N R3133 Meter 1 K Factor 12 Frequency Point UINT‐16 0C3D R/W R/W, ‐, R N R3134 Meter 1 comparator Error Threshold UINT‐16 0C3E R/W R/W, ‐, R Y R

Info: Registers 3n40, 3n42, 3n44, 4n492s complement number based on span entries 17176‐17189. Values express as percentage of span in tenth percent increments; i.e. 1000 represents 100%.

Info: Registers 3n41, 3n43, 3n45, 3n50Unsigned integer totalizer cumulative based.  They roll at 65536.

Page38 of 229 1/25/2013

Page 39: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Info: Registers 3n46, 3n47, 3n482s complement number based on the 4‐20 mA spans. Values are expressed as percentages of span in tenth percent; i.e. 1000 equal 100%

3140 Meter 1 Net Flowrate % ( 0 ‐ 999) UINT‐16 0C44 R  R, ‐, R R3141 Meter 1 Net Total 16 Bits UINT‐16 0C45 R Unsigned integer totalizer cumulative based. It rolls at 

65536.  R, ‐, R R

3142 Meter 1 Gross Flowrate % ( 0 ‐ 999) UINT‐16 0C46 R  R, ‐, R R3143 Meter 1 Gross Total 16 Bits UINT‐16 0C47 R Unsigned integer totalizer cumulative based. It rolls at 

65536.  R, ‐, R R

3144 Meter 1 Mass Flowrate % ( 0 ‐ 999) UINT‐16 0C48 R  R, ‐, R R3145 Meter 1 Mass Total 16 Bits UINT‐16 0C49 R Unsigned integer totalizer cumulative based. It rolls at 

65536.  R, ‐, R R

3146 Meter 1 Pressure % ( 0 ‐ 999) UINT‐16 0C4A R  R, ‐, R R3147 Meter 1 Temperature % ( 0 ‐ 999) UINT‐16 0C4B R  R, ‐, R R3148 Meter 1 Gravity/Density % ( 0 ‐ 999) UINT‐16 0C4C R  R, ‐, R R3149 Meter 1 Net Standard Flowrate % ( 0 ‐ 

999)UINT‐16 0C4D R   R, ‐, R R

3150 Meter 1 Net Standard Total 16 Bits UINT‐16 0C4E R Unsigned integer totalizer cumulative based. It rolls at 65536.

  R, ‐, R R

3151 Meter 1 Move Previous Batch 'n' to Print Area

UINT‐16 0C4F R/W  R/W, ‐, R Y R

3152 Meter 1 Previous Batch 'n'  of Calculation Times

UINT‐16 0C50 R   R, ‐, R R

3201 ‐ 3299 Meter 2 (Same as 3101 ‐ 3199) UINT‐16 0C81 R/W R/W, ‐, R R3301 ‐ 3399 Meter 3 (Same as 3101 ‐ 3199) UINT‐16 0CE5 R/W R/W, ‐, R R3401 ‐ 3499 Meter 4 (Same as 3101 ‐ 3199) UINT‐16 0D49 R/W R/W, ‐, R R

16 Bit Integer Data. (Scratchpad Variables)

3501 ‐ 3599 Scratchpad Variable UINT‐16 0DAD R/W R/W, ‐, R RPage39 of 229 1/25/2013

Page 40: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

16 Bit Integer Data. (Defines Index & Decimal of User Display Variables)

3601 User Display 1 Variable 1 Index UINT‐16 0E11 R/W R/W, ‐, R N R3602 User Display 1 Var 1 Decimal Places UINT‐16 0E12 R/W R/W, ‐, R N R3603 User Display 1 Variable 2 Index UINT‐16 0E13 R/W R/W, ‐, R N R3604 User Display 1 Var 2 Decimal Places UINT‐16 0E14 R/W R/W, ‐, R N R3605 User Display 1 Variable 3 Index UINT‐16 0E15 R/W R/W, ‐, R N R3606 User Display 1 Var 3 Decimal Places UINT‐16 0E16 R/W R/W, ‐, R N R3607 User Display 1 Variable 4 Index UINT‐16 0E17 R/W R/W, ‐, R N R3608 User Display 1 Var 4 Decimal Places UINT‐16 0E18 R/W R/W, ‐, R N R3609 User Display 2 Variable 1 Index UINT‐16 0E19 R/W R/W, ‐, R N R3610 User Display 2 Var 1 Decimal Places UINT‐16 0E1A R/W R/W, ‐, R N R3611 User Display 2 Variable 2 Index UINT‐16 0E1B R/W R/W, ‐, R N R3612 User Display 2 Var 2 Decimal Places UINT‐16 0E1C R/W R/W, ‐, R N R3613 User Display 2 Variable 3 Index UINT‐16 0E1D R/W R/W, ‐, R N R3614 User Display 2 Var 3 Decimal Places UINT‐16 0E1E R/W R/W, ‐, R N R3615 User Display 2 Variable 4 Index UINT‐16 0E1F R/W R/W, ‐, R N R3616 User Display 2 Var 4 Decimal Places UINT‐16 0E20 R/W R/W, ‐, R N R3617 User Display 3 Variable 1 Index UINT‐16 0E21 R/W R/W, ‐, R N R3618 User Display 3 Var 1 Decimal Places UINT‐16 0E22 R/W R/W, ‐, R N R3619 User Display 3 Variable 2 Index UINT‐16 0E23 R/W R/W, ‐, R N R3620 User Display 3 Var 2 Decimal Places UINT‐16 0E24 R/W R/W, ‐, R N R3621 User Display 3 Variable 3 Index UINT‐16 0E25 R/W R/W, ‐, R N R3622 User Display 3 Var 3 Decimal Places UINT‐16 0E26 R/W R/W, ‐, R N R3623 User Display 3 Variable 4 Index UINT‐16 0E27 R/W R/W, ‐, R N R3624 User Display 3 Var 4 Decimal Places UINT‐16 0E28 R/W R/W, ‐, R N R3625 User Display 4 Variable 1 Index UINT‐16 0E29 R/W R/W, ‐, R N R3626 User Display 4 Var 1 Decimal Places UINT‐16 0E2A R/W R/W, ‐, R N R3627 User Display 4 Variable 2 Index UINT‐16 0E2B R/W R/W, ‐, R N R3628 User Display 4 Var 2 Decimal Places UINT‐16 0E2C R/W R/W, ‐, R N R3629 User Display 4 Variable 3 Index UINT‐16 0E2D R/W R/W, ‐, R N R3630 User Display 4 Var 3 Decimal Places UINT‐16 0E2E R/W R/W, ‐, R N R3631 User Display 4 Variable 4 Index UINT‐16 0E2F R/W R/W, ‐, R N R3632 User Display 4 Var 4 Decimal Places UINT‐16 0E30 R/W R/W, ‐, R N R3633 User Display 5 Variable 1 Index UINT‐16 0E31 R/W R/W, ‐, R N R3634 User Display 5 Var 1 Decimal Places UINT‐16 0E32 R/W R/W, ‐, R N R3635 User Display 5 Variable 2 Index UINT‐16 0E33 R/W R/W, ‐, R N R

Page40 of 229 1/25/2013

Page 41: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3636 User Display 5 Var 2 Decimal Places UINT‐16 0E34 R/W R/W, ‐, R N R3637 User Display 5 Variable 3 Index UINT‐16 0E35 R/W R/W, ‐, R N R3638 User Display 5 Var 3 Decimal Places UINT‐16 0E36 R/W R/W, ‐, R N R3639 User Display 5 Variable 4 Index UINT‐16 0E37 R/W R/W, ‐, R N R3640 User Display 5 Var 4 Decimal Places UINT‐16 0E38 R/W R/W, ‐, R N R3641 User Display 6 Variable 1 Index UINT‐16 0E39 R/W R/W, ‐, R N R3642 User Display 6 Var 1 Decimal Places UINT‐16 0E3A R/W R/W, ‐, R N R3643 User Display 6 Variable 2 Index UINT‐16 0E3B R/W R/W, ‐, R N R3644 User Display 6 Var 2 Decimal Places UINT‐16 0E3C R/W R/W, ‐, R N R3645 User Display 6 Variable 3 Index UINT‐16 0E3D R/W R/W, ‐, R N R3646 User Display 6 Var 3 Decimal Places UINT‐16 0E3E R/W R/W, ‐, R N R3647 User Display 6 Variable 4 Index UINT‐16 0E3F R/W R/W, ‐, R N R3648 User Display 6 Var 4 Decimal Places UINT‐16 0E40 R/W R/W, ‐, R N R3649 User Display 7 Variable 1 Index UINT‐16 0E41 R/W R/W, ‐, R N R3650 User Display 7 Var 1 Decimal Places UINT‐16 0E42 R/W R/W, ‐, R N R3651 User Display 7 Variable 2 Index UINT‐16 0E43 R/W R/W, ‐, R N R3652 User Display 7 Var 2 Decimal Places UINT‐16 0E44 R/W R/W, ‐, R N R3653 User Display 7 Variable 3 Index UINT‐16 0E45 R/W R/W, ‐, R N R3654 User Display 7 Var 3 Decimal Places UINT‐16 0E46 R/W R/W, ‐, R N R3655 User Display 7 Variable 4 Index UINT‐16 0E47 R/W R/W, ‐, R N R3656 User Display 7 Var 4 Decimal Places UINT‐16 0E48 R/W R/W, ‐, R N R3657 User Display 8 Variable 1 Index UINT‐16 0E49 R/W R/W, ‐, R N R3658 User Display 8 Var 1 Decimal Places UINT‐16 0E4A R/W R/W, ‐, R N R3659 User Display 8 Variable 2 Index UINT‐16 0E4B R/W R/W, ‐, R N R3660 User Display 8 Var 2 Decimal Places UINT‐16 0E4C R/W R/W, ‐, R N R3661 User Display 8 Variable 3 Index UINT‐16 0E4D R/W R/W, ‐, R N R3662 User Display 8 Var 3 Decimal Places UINT‐16 0E4E R/W R/W, ‐, R N R3663 User Display 8 Variable 4 Index UINT‐16 0E4F R/W R/W, ‐, R N R3664 User Display 8 Var 4 Decimal Places UINT‐16 0E50 R/W R/W, ‐, R N R3665 ‐ 3670 Reserved3697 ‐ 3699 Reserved

16 Bit Integer Data

3701 Archive 701 Maximum Records UINT‐16 0E75 R/W R/W, R, R R3702 Archive 701 Current Record Number UINT‐16 0E76 R  R, R, R R3703 Archive 701 Request Record Number UINT‐16 0E77 R/W R/W, R/W, R/W R3704 Archive 702 Maximum Records UINT‐16 0E78 R/W R/W, R, R R

Page41 of 229 1/25/2013

Page 42: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3705 Archive 702 Current Record Number UINT‐16 0E79 R  R, R, R R3706 Archive 702 Request Record Number UINT‐16 0E7A R/W R/W, R/W, R/W R3707 Archive 703 Maximum Records UINT‐16 0E7B R/W R/W, R, R R3708 Archive 703 Current Record Number UINT‐16 0E7C R  R, R, R R3709 Archive 703 Request Record Number UINT‐16 0E7D R/W R/W, R/W, R/W R3710 Archive 704 Maximum Records UINT‐16 0E7E R/W R/W, R, R R3711 Archive 704 Current Record Number UINT‐16 0E7F R  R, R, R R3712 Archive 704 Request Record Number UINT‐16 0E80 R/W R/W, R/W, R/W R3713 Archive 705 Maximum Records UINT‐16 0E81 R/W R/W, R, R R3714 Archive 705 Current Record Number UINT‐16 0E82 R  R, R, R R3715 Archive 705 Request Record Number UINT‐16 0E83 R/W R/W, R/W, R/W R3716 Archive 706 Maximum Records UINT‐16 0E84 R/W R/W, R, R R3717 Archive 706 Current Record Number UINT‐16 0E85 R  R, R, R R3718 Archive 706 Request Record Number UINT‐16 0E86 R/W R/W, R/W, R/W R3719 Archive 707 Maximum Records UINT‐16 0E87 R/W R/W, R, R R3720 Archive 707 Current Record Number UINT‐16 0E88 R  R, R, R R3721 Archive 707 Request Record Number UINT‐16 0E89 R/W R/W, R/W, R/W R3722 Archive 708 Maximum Records UINT‐16 0E8A R/W R/W, R, R R3723 Archive 708 Current Record Number UINT‐16 0E8B R  R, R, R R3724 Archive 708 Request Record Number UINT‐16 0E8C R/W R/W, R/W, R/W R3725 Archive 709 Maximum Records UINT‐16 0E8D R/W R/W, R, R R3726 Archive 709 Current Record Number UINT‐16 0E8E R  R, R, R R3727 Archive 709 Request Record Number UINT‐16 0E8F R/W R/W, R/W, R/W R3728 Archive 710 Maximum Records UINT‐16 0E90 R/W R/W, R, R R3729 Archive 710 Current Record Number UINT‐16 0E91 R  R, R, R R3730 Archive 710 Request Record Number UINT‐16 0E92 R/W R/W, R/W, R/W R3731 Archive 711 Maximum Records UINT‐16 0E93 R/W R/W, R, R R3732 Archive 711 Current Record Number UINT‐16 0E94 R  R, R, R R3733 Archive 711 Request Record Number UINT‐16 0E95 R/W R/W, R/W, R/W R3734 Archive 712 Maximum Records UINT‐16 0E96 R/W R/W, R, R R3735 Archive 712 Current Record Number UINT‐16 0E97 R  R, R,  R R3736 Archive 712 Request Record Number UINT‐16 0E98 R/W R/W, R/W, R/W R3737 Archive File Status (0=OK, 1=Error) UINT‐16 0E99 R  R, ‐, R R3738 Time Tag in MMDDor DDMM Format UINT‐16 0E9A R  R, ‐, R R3739 Time Tag in YYHH Format UINT‐16 0E9B R  R, ‐, R R3740 Time Tag in MMSS Format UINT‐16 0E9C R  R, ‐, R R

Page42 of 229 1/25/2013

Page 43: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3741 New Archive File Exists Bit (B0=Arc701, B9=Arc710)

UINT‐16 0E9D R   R, ‐, R R

3742 ‐ 3744 Reserved3745 Batch End ‐ No Stack Operation (0=No, 

1=Yes)UINT‐16 0EA1 R/W  R/W, ‐, R N R

3746 Starting Index of Displayed Database Registers

UINT‐16 0EA2 R/W  R/W, ‐, R Y R

3747 Default Snapshot Report Template (Y/N) UINT‐16 0EA3 R/W R/W, ‐, R N R3748 Default Batch Report Template (Y/N) UINT‐16 0EA4 R/W R/W, ‐, R N R3749 Default Daily Report Template (Y/N) UINT‐16 0EA5 R/W R/W, ‐, R N R3750 Default Prove Report Template (Y/N) UINT‐16 0EA6 R/W R/W, ‐, R N R3769 Number of Historical Alarms to Be 

RetrievedUINT‐16 0EB9 R/W R/W, R/W, R/W Y R

3781 Product  1 Use Observed Density Y/N (API 11.1)

UINT‐16 0EC5 R/W  R/W, ‐, R Y R

Product  1 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3782 Product  2 Use Observed Density Y/N (API 11.1)

UINT‐16 0EC6 R/W  R/W, ‐, R Y R

Product  2 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3783 Product  3 Use Observed Density Y/N (API 11.1)

UINT‐16 0EC7 R/W  R/W, ‐, R Y R

Product  3 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3784 Product  4 Use Observed Density Y/N (API 11.1)

UINT‐16 0EC8 R/W  R/W, ‐, R Y R

Page43 of 229 1/25/2013

Page 44: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Product  4 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3785 Product  5 Use Observed Density Y/N (API 11.1)

UINT‐16 0EC9 R/W  R/W, ‐, R Y R

Product  5 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3786 Product  6 Use Observed Density Y/N (API 11.1)

UINT‐16 0ECA R/W  R/W, ‐, R Y R

Product  6 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3787 Product  7 Use Observed Density Y/N (API 11.1)

UINT‐16 0ECB R/W  R/W, ‐, R Y R

Product  7 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3788 Product  8 Use Observed Density Y/N (API 11.1)

UINT‐16 0ECC R/W  R/W, ‐, R Y R

Product  8 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3789 Product  9 Use Observed Density Y/N (API 11.1)

UINT‐16 0ECD R/W  R/W, ‐, R Y R

Product  9 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3790 Product  10 Use Observed Density Y/N (API 11.1)

UINT‐16 0ECE R/W  R/W, ‐, R Y R

Page44 of 229 1/25/2013

Page 45: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Product  10 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3791 Product  11 Use Observed Density Y/N (API 11.1)

UINT‐16 0ECF R/W  R/W, ‐, R Y R

Product  11 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3792 Product  12 Use Observed Density Y/N (API 11.1)

UINT‐16 0ED0 R/W  R/W, ‐, R Y R

Product  12 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3793 Product  13 Use Observed Density Y/N (API 11.1)

UINT‐16 0ED1 R/W  R/W, ‐, R Y R

Product  13 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3794 Product  14 Use Observed Density Y/N (API 11.1)

UINT‐16 0ED2 R/W  R/W, ‐, R Y R

Product  14 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3795 Product  15 Use Observed Density Y/N (API 11.1)

UINT‐16 0ED3 R/W  R/W, ‐, R Y R

Product  15 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3796 Product  16 Use Observed Density Y/N (API 11.1)

UINT‐16 0ED4 R/W  R/W, ‐, R Y R

Page45 of 229 1/25/2013

Page 46: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Product  16 Use API 11.1 Pressure Correction(Y/N)

R/W  R/W, ‐, R Y R

3797 ‐ 3799 Reserved

16 Bit Integer Data

Info: Register 3800To avoid flushing the audit trail, audit events other than complete ‘downloads’ to the flow computer are usually not documented in the ‘audit trail’ unless serial port passwRigorous auditing of a serial port or group of serial ports can be activated by placing the appropriate hexadecimal code in 3800  (S= Serial Port).00 00 00 AA = Audit S1 00 00 AA 00 = Audit S2 00 AA 00 00 = Audit S3 AA 00 00 00 = Audit S4 00 00 00 05 = Audit S5 00 00 00 50 = Audit S6To monitor mul ple ports; e.g: A

Info: Registers 3803, 3805, 3807Unsigned integer totalizers cumulative based. They roll at 65536.

Info: Registers 3802, 3804, 3806, 3808, 3809, 38102s complement numbers based on span entries 17176 through 17189. Values expressed as percentages of span in tenth percent increments. i.e. 1000 represents 100.0%. No over range or under range checking is done.

3800 Special Diagnostic Function UINT‐16 0ED8 R/W R/W, ‐, R RUsed to enable 'Audit Trail'reporting of all serial port

3801 Station Running Product Number UINT‐16 0ED9 R  R, ‐, R R3802 Station Current Net(GSV) Flowrate UINT‐16 0EDA R  R, ‐, R R3803 Station Net Total 16 Bits UINT‐16 0EDB R  R, ‐, R R3804 Station Current Gross (IV) Flowrate % (0 ‐ 

999)UINT‐16 0EDC R   R, ‐, R R

3805 Station Gross (IV) Total 16 Bits UINT‐16 0EDD R  R, ‐, R R3806 Station Mass Flowrate % (0 ‐ 999) UINT‐16 0EDE R  R, ‐, R R3807 Station Mass Total 16 Bits UINT‐16 0EDF R  R, ‐, R R3808 Station Pressure % (0 ‐999) UINT‐16 0EE0 R  R, ‐, R R3809 Station Temperature % (0 ‐999) UINT‐16 0EE1 R  R, ‐, R R3810 Station Gravity/Density % (0 ‐999) UINT‐16 0EE2 R  R, ‐, R R3811 Allen Bradley ‐CRC Error Counter UINT‐16 0EE3 R  R, ‐, R R3812 Allen Bradley ‐ Message Type Error 

CounterUINT‐16 0EE4 R   R, ‐, R R

Page46 of 229 1/25/2013

Page 47: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3813 Product  1 Table Select UINT‐16 0EE5 R/W R/W, R, R N R3814 Product  2 Table Select UINT‐16 0EE6 R/W R/W, R, R N R3815 Product  3 Table Select UINT‐16 0EE7 R/W R/W, R, R N R3816 Product  4 Table Select UINT‐16 0EE8 R/W R/W, R, R N R3817 Product  5 Table Select UINT‐16 0EE9 R/W R/W, R, R N R3818 Product  6 Table Select UINT‐16 0EEA R/W R/W, R, R N R3819 Product  7 Table Select UINT‐16 0EEB R/W R/W, R, R N R3820 Product  8 Table Select UINT‐16 0EEC R/W R/W, R, R N R3821 Product  9 Table Select UINT‐16 0EED R/W R/W, R, R N R3822 Product  10 Table Select UINT‐16 0EEE R/W R/W, R, R N R3823 Product  11 Table Select UINT‐16 0EEF R/W R/W, R, R N R3824 Product  12 Table Select UINT‐16 0EF0 R/W R/W, R, R N R3825 Product  13 Table Select UINT‐16 0EF1 R/W R/W, R, R N R3826 Product  14 Table Select UINT‐16 0EF2 R/W R/W, R, R N R3827 Product  15 Table Select UINT‐16 0EF3 R/W R/W, R, R N R3828 Product  16 Table Select UINT‐16 0EF4 R/W R/W, R, R N R3829 Flowrate Average Factor UINT‐16 0EF5 R/W R/W, ‐, R N R3830 Print Priority UINT‐16 0EF6 R/W R/W, ‐, R N R3831 Number of Nulls After CR UINT‐16 0EF7 R/W R/W, ‐, R N R3832 Print Interval in Minutes UINT‐16 0EF8 R/W R/W, ‐, R N R3833 Weekly Batch Select ( 1 ‐ 7) UINT‐16 0EF9 R/W R/W, ‐, R N R3834 Monthly Batch Select ( 1 ‐ 31) UINT‐16 0EFA R/W R/W, ‐, R N R3835 Hourly Batch Select(Y/N) UINT‐16 0EFB R/W R/W, ‐, R N R3837 Common Batch Stack (Y/N) UINT‐16 0EFD R/W R/W, R, R Y R3838 Clear Daily at Batch End UINT‐16 0EFE R/W R/W, ‐, R N R3840 Dual Pulse Delay Cycle UINT‐16 0F00 R/W R/W, ‐, R N R3842 Select Date 0=dd/mm/yy, 1=mm/dd/yy UINT‐16 0F02 R/W R/W, R, R Y R3843 M1 SEQ 1 PROD NO (or 1) UINT‐16 0F03 R/W R/W, R/W, R Y R3844 M1 SEQ 2 PROD NO (or 2) UINT‐16 0F04 R/W R/W, R/W, R Y R3845 M1 SEQ 3 PROD NO (or 3) UINT‐16 0F05 R/W R/W, R/W, R Y R3846 M1 SEQ 4 PROD NO (or 4) UINT‐16 0F06 R/W R/W, R/W, R Y R3847 M1 SEQ 5 PROD NO (or 5) UINT‐16 0F07 R/W R/W, R/W, R Y R3848 M1 SEQ 6 PROD NO (or 6) UINT‐16 0F08 R/W R/W, R/W, R Y R3849 M2 SEQ 1 PROD NO (or 7) UINT‐16 0F09 R/W R/W, R/W, R Y R3850 M2 SEQ 2 PROD NO (or 8) UINT‐16 0F0A R/W R/W, R/W, R Y R3851 M2 SEQ 3 PROD NO (or 9) UINT‐16 0F0B R/W R/W, R/W, R Y R3852 M2 SEQ 4 PROD NO (or 10) UINT‐16 0F0C R/W R/W, R/W, R Y R3853 M2 SEQ 5 PROD NO (or 11) UINT‐16 0F0D R/W R/W, R/W, R Y R

Page47 of 229 1/25/2013

Page 48: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3854 M2 SEQ 6 PROD NO (or 12) UINT‐16 0F0E R/W R/W, R/W, R Y R3855 M3 SEQ 1 PROD NO (or 13) UINT‐16 0F0F R/W R/W, R/W, R Y R3856 M3 SEQ 2 PROD NO (or 14) UINT‐16 0F10 R/W R/W, R/W, R Y R3857 M3 SEQ 3 PROD NO (or 15) UINT‐16 0F11 R/W R/W, R/W, R Y R3858 M3 SEQ 4 PROD NO (or 16) UINT‐16 0F12 R/W R/W, R/W, R Y R3859 M3 SEQ 5 PROD NO (or 17) UINT‐16 0F13 R/W R/W, R/W, R Y R3860 M3 SEQ 6 PROD NO (or 18) UINT‐16 0F14 R/W R/W, R/W, R Y R3861 M4 SEQ 1 PROD NO (or 19) UINT‐16 0F15 R/W R/W, R/W, R Y R3862 M4 SEQ 2 PROD NO (or 20) UINT‐16 0F16 R/W R/W, R/W, R Y R3863 M4 SEQ 3 PROD NO (or 21) UINT‐16 0F17 R/W R/W, R/W, R Y R3864 M4 SEQ 4 PROD NO (or 22) UINT‐16 0F18 R/W R/W, R/W, R Y R3865 M4 SEQ 5 PROD NO (or 23) UINT‐16 0F19 R/W R/W, R/W, R Y R3866 M4 SEQ 6 PROD NO (or 24) UINT‐16 0F1A R/W R/W, R/W, R Y R3867 CURRENT HOUR UINT‐16 0F1B R/W R/W, ‐, R R3868 CURRENT MINUTE UINT‐16 0F1C R/W R/W, ‐, R R3869 CURRENT SECOND UINT‐16 0F1D R/W R/W, ‐, R R3870 CURRENT MONTH UINT‐16 0F1E R/W R/W, ‐, R R3871 CURRENT DATE UINT‐16 0F1F R/W R/W, ‐, R R3872 CURRENT YEAR UINT‐16 0F20 R/W R/W, ‐, R R3873 DAY OF WEEK UINT‐16 0F21 R/W R/W, ‐, R R3874 Disable Daily Report (0=No, 1=Yes) UINT‐16 0F22 R/W R/W, ‐, R N R3875 Julian Day( of days since first day of 

January)UINT‐16 0F23 R   R, ‐, R R

3876 Station Density Override Code UINT‐16 0F24 R/W R/W, ‐, R Y R3877 Station Density Temperature Override 

CodeUINT‐16 0F25 R/W  R/W, ‐, R Y R

3878 Station Density Pressure Override Code UINT‐16 0F26 R/W R/W, ‐, R Y R3879 Station Move Previous 'n' Batch to Print 

AreaUINT‐16 0F27 R/W  R/W, ‐, R Y R

3880 Density Factor Select Product 1 UINT‐16 0F28 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

Page48 of 229 1/25/2013

Page 49: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3881 Density Factor Select Product 2 UINT‐16 0F29 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3882 Density Factor Select Product 3 UINT‐16 0F2A R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3883 Density Factor Select Product 4 UINT‐16 0F2B R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3884 Density Factor Select Product 5 UINT‐16 0F2C R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3885 Density Factor Select Product 6 UINT‐16 0F2D R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3886 Density Factor Select Product 7 UINT‐16 0F2E R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3887 Density Factor Select Product 8 UINT‐16 0F2F R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

Page49 of 229 1/25/2013

Page 50: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3888 Density Factor Select Product 9 UINT‐16 0F30 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3889 Density Factor Select Product 10 UINT‐16 0F31 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3890 Density Factor Select Product 11 UINT‐16 0F32 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3891 Density Factor Select Product 12 UINT‐16 0F33 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3892 Density Factor Select Product 13 UINT‐16 0F34 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3893 Density Factor Select Product 14 UINT‐16 0F35 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

3894 Density Factor Select Product 15 UINT‐16 0F36 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

Page50 of 229 1/25/2013

Page 51: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3895 Density Factor Select Product 16 UINT‐16 0F37 R/W 0=DCF A.1=DCF B.2=Product DCF.

 R/W, ‐, R N R

16 Bit Integer Data

3901 Prove Run UINT‐16 0F3D R  R, R, R R3902 Proving Meter Number UINT‐16 0F3E R  R, R, R R3903 Outlet Pressure % (0 ‐ 999) UINT‐16 0F3F R  R, ‐, R R3904 Outlet Temperature % (0 ‐ 999) UINT‐16 0F40 R  R, ‐, R R3905 Inlet Pressure % ( 0 ‐ 999) UINT‐16 0F41 R  R, ‐, R R3906 Inlet Temperature % ( 0 ‐ 999) UINT‐16 0F42 R  R, ‐, R R3907 Prove Counts UINT‐16 0F43 R  R, ‐, R R3908 Prover Density/Gravity Override Code UINT‐16 0F44 R/W R/W, ‐, R Y R3909 Prover Dens Temperature Override Code UINT‐16 0F45 R/W R/W, ‐, R Y R3910 Prover Dens Pressure Override Code UINT‐16 0F46 R/W R/W, ‐, R Y R3911 Enable Trial Prove Report(0=N,1=Y) UINT‐16 0F47 R/W R/W, ‐, R Y R3912 Number of Passes/Run UINT‐16 0F48 R/W R/W, R, R Y R3913 Number of Prover Runs to Avg UINT‐16 0F49 R/W R/W, ‐, R Y R3914 Number of Total Prove Runs UINT‐16 0F4A R/W R/W, ‐, R Y R3915 Inactivity Timer (Seconds) UINT‐16 0F4B R/W R/W, ‐, R Y R3916 Temp Stability Sample Time UINT‐16 0F4C R/W R/W, ‐, R Y R3917 Override Code Inlet Temperature UINT‐16 0F4D R/W R/W, ‐, R Y R3918 Override Code Outlet Temperature UINT‐16 0F4E R/W R/W, ‐, R Y R3919 Override Code Inlet Pressure UINT‐16 0F4F R/W R/W, ‐, R Y R3920 Override Code Outlet Pressure UINT‐16 0F50 R/W R/W, ‐, R Y R3921 Prover Type UINT‐16 0F51 R/W 0=Unidirectional Pipe prover

1=Bi‐directional pipe prover2=Uni‐directional compact prover3=Bi‐directional small volume prover4=Master meter prover5=2 series prover

 R/W, R, R Y R

3922 Automatic Implement Prove MF UINT‐16 0F52 R/W R/W, R/W, R Y R3923 Apply Meter Factor Retroactively (Y/N) UINT‐16 0F53 R/W R/W, ‐, R Y R3924 Prover Density Stability Timer UINT‐16 0F54 R/W R/W, ‐, R Y R

Page51 of 229 1/25/2013

Page 52: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

3925 Flow Stable Period (min) UINT‐16 0F55 R/W R/W, ‐, R Y R3926 Meter Down Period (Hours) UINT‐16 0F56 R/W R/W, ‐, R Y R3927 Print Passes ? (0=No, 1=Yes) UINT‐16 0F57 R/W R/W, ‐, R Y R3928 Run Repeatibility on MF (0=No, 1=Yes) UINT‐16 0F58 R/W R/W, R, R Y R3929 Archive All Prove Report (0=No, 1=Yes) UINT‐16 0F59 R/W R/W, ‐, R Y R3930 Proving Meter Temperature 

CompensatedUINT‐16 0F5A R   R, ‐, R R

3931 Proving Run Number Last ‐ 3 UINT‐16 0F5B R  R, R, R R3932 Proving Run Number Last ‐ 2 UINT‐16 0F5C R  R, R, R R3933 Proving Run Number Last ‐ 1 UINT‐16 0F5D R  R, R, R R3934 Proving Run Number Last UINT‐16 0F5E R  R, R, R R3935 Proving Run Number 1st Run UINT‐16 0F5F R  R, R, R R3936 Proving Run Number 2nd Run UINT‐16 0F60 R  R, R, R R3937 Proving Run Number 3rd Run UINT‐16 0F61 R  R, R, R R3938 Proving Run Number 4th Run UINT‐16 0F62 R  R, R, R R3939 Proving Run Number 5th Run UINT‐16 0F63 R  R, R, R R3940 Proving Run Number 6th Run UINT‐16 0F64 R  R, R, R R3941 Proving Run Number 7th Run UINT‐16 0F65 R  R, R, R R3942 Proving Run Number 8th Run UINT‐16 0F66 R  R, R, R R3943 Proving Run Number 9th Run UINT‐16 0F67 R  R, R, R R3944 Proving Run Number 10th Run UINT‐16 0F68 R  R, R, R R3945 Current Prove Passes UINT‐16 0F69 R  R, R, R R3947 Switch Bar Temperature Override Code UINT‐16 0F6B R/W R/W, ‐, R Y R

4000 s are 8 char Ascii strings (4 registers each)The 2nd digit defines the meter run Info: These ASCII string variables are accessed using Modbus function codes 03 for reads and 16 for writes.

Info: The index number of each string refers to the complete string which occupies the space of 4 registers. It must be accessed as a complete unit. You can not read or writEach point counts as one point in the normal OMNI Modbus mode.

Info: Modicon Compatable Mode – For the purpose of point count only, each string counts as 4 registers. The starting address of the string still applies.

4101 Meter 1 Running Batch ‐ Start Date ASCII‐8 1005 R  R, R, R R4102 Meter 1 Running Batch ‐ Start Time ASCII‐8 1006 R  R, R, R R

Info: Registers 4n03, 4n04 ‐ Last batch end for this meter run.

Page52 of 229 1/25/2013

Page 53: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4103 Meter 1 Last Batch Ended Date ASCII‐8 1007 R  R, ‐, R R4104 Meter 1 Last Batch Ended Time ASCII‐8 1008 R  R, ‐, R R4105 Meter 1 Running Product Name ASCII‐8 1009 R  R, ‐, R R4106 Meter 1 Current Calculation Mode ASCII‐8 100A R  R, ‐, R R4107 Meter 1 Current Batch ID (Chars 1 ‐ 8) ASCII‐8 100B R  R, ‐, R R4108 Meter 1 Current Batch ID (Chars 9 ‐ 16) ASCII‐8 100C R   R, ‐, R R

4109 Meter 1 Meter Factor Used in Net/Mass ASCII‐8 100D R  R, ‐, R R4110 Meter 1 Linear Correction Factor Used in 

GrossASCII‐8 100E R   R, ‐, R R

4111 Meter 1 Meter Serial Number ASCII‐8 100F R/W R/W, ‐, R N R4112 Meter 1 Meter Size ASCII‐8 1010 R/W R/W, ‐, R N R4113 Meter 1 Meter Model ASCII‐8 1011 R/W R/W, ‐, R N R4114 Meter 1 Meter ID ASCII‐8 1012 R/W R/W, ‐, R N R4115 Meter 1 Flow Meter/DP Low Tag ASCII‐8 1013 R/W R/W, ‐, R N R4117 Meter 1 Temperature Transmitter Tag ASCII‐8 1015 R/W R/W, ‐, R N R4118 Meter 1 Pressure Transmitter Tag ASCII‐8 1016 R/W R/W, ‐, R N R4119 Meter 1 Gravity/Density Transmitter Tag ASCII‐8 1017 R/W  R/W, ‐, R N R

4120 Meter 1 Density Temperature Transmitter Tag

ASCII‐8 1018 R/W  R/W, ‐, R N R

4121 Meter 1 Density Pressure Transmitter Tag ASCII‐8 1019 R/W  R/W, ‐, R N R

4122 Meter 1 PID Output Tag ASCII‐8 101A R/W R/W, ‐, R N R4126 Meter 1 Day Start Time ASCII‐8 101E R  R, ‐, R R4127 Meter 1 Day Start Date ASCII‐8 101F R  R, ‐, R R4129 ‐ 4130 Reserved4131 Meter 1 Previous Batch 'n' Batch Start 

DateASCII‐8 1023 R   R, ‐, R R

4132 Meter 1 Previous Batch 'n' Batch Start Time

ASCII‐8 1024 R   R, ‐, R R

Page53 of 229 1/25/2013

Page 54: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4133 Meter 1 Previous Batch 'n' Batch End Date

ASCII‐8 1025 R   R, ‐, R R

4134 Meter 1 Previous Batch 'n' Batch End Time

ASCII‐8 1026 R   R, ‐, R R

4135 Meter 1 Previous Batch 'n' Product Name ASCII‐8 1027 R   R, ‐, R R

4136 Meter 1 Previous Batch 'n' Calculation Mode

ASCII‐8 1028 R   R, ‐, R R

4137 Meter 1 Previous Batch 'n' Batch ID (Chars 1 ‐ 8)

ASCII‐8 1029 R   R, ‐, R R

4138 Meter 1 Previous Batch 'n' Batch ID (Chars 9 ‐16)

ASCII‐8 102A R   R, ‐, R R

4139 Meter 1 Previous Batch 'n' MF Used in Net/Mass

ASCII‐8 102B R   R, ‐, R R

4140 Meter 1 Previous Day Start Time ASCII‐8 102C R  R, ‐, R R4141 Meter 1 Previous Day Start Date ASCII‐8 102D R  R, ‐, R R4142 Meter 1 Previous Day End Time ASCII‐8 102E R  R, ‐, R R4143 Meter 1 Previous Day End Date ASCII‐8 102F R  R, ‐, R R4145 Meter 1 Previous Day Product Name ASCII‐8 1031 R  R, ‐, R R4146 Meter 1 Previous Day Calculation Mode ASCII‐8 1032 R  R, ‐, R R4147 Reserved4148 Reserved4149 Meter 1 Previous Day Meter Factor Used 

in Net/MassASCII‐8 1035 R   R, ‐, R R

4150 Meter 1 Previous Day Linear Correction Factor Used in Gross

ASCII‐8 1036 R   R, ‐, R R

4151 ‐ 4199 Reserved

4201 ‐ 4299 Meter 2 (Same as 4101 ‐ 4199) ASCII‐8 1069 R/W R/W, ‐, R RPage54 of 229 1/25/2013

Page 55: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4301 ‐ 4399 Meter 3 (Same as 4101 ‐ 4199) ASCII‐8 10CD R/W R/W, ‐, R R4401 ‐ 4499 Meter 4 (Same as 4101 ‐ 4199) ASCII‐8 1131 R/W R/W, ‐, R R

8 Char Ascii String. (Scratchpad Strings)

4501 ‐ 4599 Scratchpad Variable ASCII‐8 1195 R/W R/W, ‐, R R

User Display Key Presses and Tags (8 char Ascii strings)

4601 User Display 1 Variable 1 Tag ASCII‐8 11F9 R/W R/W, ‐, R N R4602 User Display 1 Variable 2 Tag ASCII‐8 11FA R/W R/W, ‐, R N R4603 User Display 1 Variable 3 Tag ASCII‐8 11FB R/W R/W, ‐, R N R4604 User Display 1 Variable 4 Tag ASCII‐8 11FC R/W R/W, ‐, R N R4605 User Display 2 Variable 1 Tag ASCII‐8 11FD R/W R/W, ‐, R N R4606 User Display 2 Variable 2 Tag ASCII‐8 11FE R/W R/W, ‐, R N R4607 User Display 2 Variable 3 Tag ASCII‐8 11FF R/W R/W, ‐, R N R4608 User Display 2 Variable 4 Tag ASCII‐8 1200 R/W R/W, ‐, R N R4609 User Display 3 Variable 1 Tag ASCII‐8 1201 R/W R/W, ‐, R N R4610 User Display 3 Variable 2 Tag ASCII‐8 1202 R/W R/W, ‐, R N R4611 User Display 3 Variable 3 Tag ASCII‐8 1203 R/W R/W, ‐, R N R4612 User Display 3 Variable 4 Tag ASCII‐8 1204 R/W R/W, ‐, R N R4613 User Display 4 Variable 1 Tag ASCII‐8 1205 R/W R/W, ‐, R N R4614 User Display 4 Variable 2 Tag ASCII‐8 1206 R/W R/W, ‐, R N R4615 User Display 4 Variable 3 Tag ASCII‐8 1207 R/W R/W, ‐, R N R4616 User Display 4 Variable 4 Tag ASCII‐8 1208 R/W R/W, ‐, R N R4617 User Display 5 Variable 1 Tag ASCII‐8 1209 R/W R/W, ‐, R N R4618 User Display 5 Variable 2 Tag ASCII‐8 120A R/W R/W, ‐, R N R4619 User Display 5 Variable 3 Tag ASCII‐8 120B R/W R/W, ‐, R N R4620 User Display 5 Variable 4 Tag ASCII‐8 120C R/W R/W, ‐, R N R4621 User Display 6 Variable 1 Tag ASCII‐8 120D R/W R/W, ‐, R N R4622 User Display 6 Variable 2 Tag ASCII‐8 120E R/W R/W, ‐, R N R4623 User Display 6 Variable 3 Tag ASCII‐8 120F R/W R/W, ‐, R N R4624 User Display 6 Variable 4 Tag ASCII‐8 1210 R/W R/W, ‐, R N R4625 User Display 7 Variable 1 Tag ASCII‐8 1211 R/W R/W, ‐, R N R4626 User Display 7 Variable 2 Tag ASCII‐8 1212 R/W R/W, ‐, R N R4627 User Display 7 Variable 3 Tag ASCII‐8 1213 R/W R/W, ‐, R N R4628 User Display 7 Variable 4 Tag ASCII‐8 1214 R/W R/W, ‐, R N R4629 User Display 8 Variable 1 Tag ASCII‐8 1215 R/W R/W, ‐, R N R

Page55 of 229 1/25/2013

Page 56: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4630 User Display 8 Variable 2 Tag ASCII‐8 1216 R/W R/W, ‐, R N R4631 User Display 8 Variable 3 Tag ASCII‐8 1217 R/W R/W, ‐, R N R4632 User Display 8 Variable 4 Tag ASCII‐8 1218 R/W R/W, ‐, R N R4633 User Display 1 Key Press ASCII‐8 1219 R/W R/W, ‐, R N R4634 User Display 2 Key Press ASCII‐8 121A R/W R/W, ‐, R N R4635 User Display 3 Key Press ASCII‐8 121B R/W R/W, ‐, R N R4636 User Display 4 Key Press ASCII‐8 121C R/W R/W, ‐, R N R4637 User Display 5 Key Press ASCII‐8 121D R/W R/W, ‐, R N R4638 User Display 6 Key Press ASCII‐8 121E R/W R/W, ‐, R N R4639 User Display 7 Key Press ASCII‐8 121F R/W R/W, ‐, R N R4640 User Display 8 Key Press ASCII‐8 1220 R/W R/W, ‐, R N R4641 ‐ 4699 Reserved

Station Ascii strings (8 char same as meter run strings)

4701 ‐ 4706 Reserved4707 Auxiliary Input 1 Tag ASCII‐8 1263 R/W R/W, ‐, R N R4708 Auxiliary Input 2 Tag ASCII‐8 1264 R/W R/W, ‐, R N R4709 Auxiliary Input 3 Tag ASCII‐8 1265 R/W R/W, ‐, R N R4710 Auxiliary Input 4 Tag ASCII‐8 1266 R/W R/W, ‐, R N R4711 Previous Batch Start Date ‐ Station ASCII‐8 1267 R  R, ‐, R  4712 Previous Batch Start Time ‐ Station ASCII‐8 1268 R  R, ‐, R  4713 Previous Batch End Date ‐ Station ASCII‐8 1269 R  R, ‐, R4714 Previous Batch End Time ‐ Station ASCII‐8 126A R  R, ‐, R

Station Ascii strings (8 char same as meter run strings)

4801 Station Batch Start Date ASCII‐8 12C1 R  R, R, R R4802 Station Batch Start Time ASCII‐8 12C2 R  R, R, R R4803 Station Batch End Date ASCII‐8 12C3 R  R, ‐, R R4804 Station Batch End Time ASCII‐8 12C4 R  R, ‐, R R4805 Station Running Product Name ASCII‐8 12C5 R  R, ‐, R R4806 Station Current Calculation Mode ASCII‐8 12C6 R  R, ‐, R R4807 Date of Last Configuration Data Change ASCII‐8 12C7 R  R, ‐, R R4808 Time of Last Configuration Data Change ASCII‐8 12C8 R  R, ‐, R R4809 Reserved4810 Condensed Printing String ASCII‐8 12CA R  R, ‐, R R4811 Uncondensed Printing String ASCII‐8 12CB R  R, ‐, R R

Page56 of 229 1/25/2013

Page 57: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4812 Day Light Saving Starts ASCII‐8 12CC R/W R/W, ‐, R N R4813 Day Light Saving Ends ASCII‐8 12CD R/W R/W, ‐, R N R4814 Station Gravity/Density Tag ASCII‐8 12CE R/W R/W, ‐, R N R4815 Station ID ASCII‐8 12CF R/W R/W, ‐, R N R4816 Station Density Temperature Tag ASCII‐8 12D0 R/W R/W, ‐, R N R4817 Station Density Pressure Tag ASCII‐8 12D1 R/W R/W, ‐, R N R4818 Interval Start Time ASCII‐8 12D2 R/W R/W, ‐, R N R4819 Daily Report Time ASCII‐8 12D3 R/W R/W, ‐, R N R4820 Product 1 Name ASCII‐8 12D4 R/W R/W, R, R N R4821 Product 2 Name ASCII‐8 12D5 R/W R/W, R, R N R4822 Product 3 Name ASCII‐8 12D6 R/W R/W, R, R N R4823 Product 4 Name ASCII‐8 12D7 R/W R/W, R, R N R4824 Product 5 Name ASCII‐8 12D8 R/W R/W, R, R N R4825 Product 6 Name ASCII‐8 12D9 R/W R/W, R, R N R4826 Product 7 Name ASCII‐8 12DA R/W R/W, R, R N R4827 Product 8 Name ASCII‐8 12DB R/W R/W, R, R N R4828 Product 9 Name ASCII‐8 12DC R/W R/W, R, R N R4829 Product 10 Name ASCII‐8 12DD R/W R/W, R, R N R4830 Product 11 Name ASCII‐8 12DE R/W R/W, R, R N R4831 Product 12 Name ASCII‐8 12DF R/W R/W, R, R N R4832 Product 13 Name ASCII‐8 12E0 R/W R/W, R, R N R4833 Product 14 Name ASCII‐8 12E1 R/W R/W, R, R N R4834 Product 15 Name ASCII‐8 12E2 R/W R/W, R, R N R4835 Product 16 Name ASCII‐8 12E3 R/W R/W, R, R N R4836 Computer ID ASCII‐8 12E4 R/W R/W, R, R N R4837 Company Name (Chars  1‐ 8) ASCII‐8 12E5 R/W R/W, R, R N R4838 Company Name (Chars  9‐16) ASCII‐8 12E6 R/W R/W, R, R N R4839 Company Name (Chars 17‐24) ASCII‐8 12E7 R/W R/W, R, R N R4840 Company Name (Chars 25‐32) ASCII‐8 12E8 R/W R/W, R, R N R4841 Company Name (Chars 33‐40) ASCII‐8 12E9 R/W R/W, R, R N R4842 Station Location (Chars  1‐ 8) ASCII‐8 12EA R/W R/W, R, R N R4843 Station Location (Chars  9‐16) ASCII‐8 12EB R/W R/W, R, R N R4844 Station Location (Chars 17‐24) ASCII‐8 12EC R/W R/W, R, R N R4845 Station Location (Chars 25‐32) ASCII‐8 12ED R/W R/W, R, R N R4846 Station Location (Chars 33‐40) ASCII‐8 12EE R/W R/W, R, R N R

4847 Current Date ASCII‐8 12EF R/W R/W, R, R Y R4848 Current Time ASCII‐8 12F0 R/W R/W,  R, R Y R

Page57 of 229 1/25/2013

Page 58: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4849 Software Version No ASCII‐8 12F1 R  R,  R, R R4850 Password / EPROM Checksum ASCII‐8 12F2 R/W Write command will allow to enter the password.

Read command will allow to read back the EPROM checksum.

R/W, R/W, R/W N  R

4851 Reserved4852 M1 SEQ 1 Batch ID (or Current) (ch 1‐8) ASCII‐8 12F4 R/W  R/W, R/W, R Y R

4853 M1 SEQ 1 Batch ID (or Current) (ch 9‐16) ASCII‐8 12F5 R/W  R/W, R/W, R Y R

4854 M1 SEQ 2 Batch ID (or 1) (ch 1‐8) ASCII‐8 12F6 R/W R/W, R/W, R Y R4855 M1 SEQ 2 Batch ID (or 1) (ch 9‐16) ASCII‐8 12F7 R/W R/W, R/W, R Y R4856 M1 SEQ 3 Batch ID (or 2) (ch 1‐8) ASCII‐8 12F8 R/W R/W, R/W, R Y R4857 M1 SEQ 3 Batch ID (or 2) (ch 9‐16) ASCII‐8 12F9 R/W R/W, R/W, R Y R4858 M1 SEQ 4 Batch ID (or 3) (ch 1‐8) ASCII‐8 12FA R/W R/W, R/W, R Y R4859 M1 SEQ 4 Batch ID (or 3) (ch 9‐16) ASCII‐8 12FB R/W R/W, R/W, R Y R4860 M1 SEQ 5 Batch ID (or 4) (ch 1‐8) ASCII‐8 12FC R/W R/W, R/W, R Y R4861 M1 SEQ 5 Batch ID (or 4) (ch 9‐16) ASCII‐8 12FD R/W R/W, R/W, R Y R4862 M1 SEQ 6 Batch ID (or 5) (ch 1‐8) ASCII‐8 12FE R/W R/W, R/W, R Y R4863 M1 SEQ 6 Batch ID (or 5) (ch 9‐16) ASCII‐8 12FF R/W R/W, R/W, R Y R4864 M2 SEQ 1 Batch ID (or 6) (ch 1‐8) ASCII‐8 1300 R/W R/W, R/W, R Y R4865 M2 SEQ 1 Batch ID (or 6) (ch 9‐16) ASCII‐8 1301 R/W R/W, R/W, R Y R4866 M2 SEQ 2 Batch ID (or 7) (ch 1‐8) ASCII‐8 1302 R/W R/W, R/W, R Y R4867 M2 SEQ 2 Batch ID (or 7) (ch 9‐16) ASCII‐8 1303 R/W R/W, R/W, R Y R4868 M2 SEQ 3 Batch ID (or 8) (ch 1‐8) ASCII‐8 1304 R/W R/W, R/W, R Y R4869 M2 SEQ 3 Batch ID (or 8) (ch 9‐16) ASCII‐8 1305 R/W R/W, R/W, R Y R4870 M2 SEQ 4 Batch ID (or 9) (ch 1‐8) ASCII‐8 1306 R/W R/W, R/W, R Y R4871 M2 SEQ 4 Batch ID (or 9) (ch 9‐16) ASCII‐8 1307 R/W R/W, R/W, R Y R4872 M2 SEQ 5 Batch ID (or 10) (ch 1‐8) ASCII‐8 1308 R/W R/W, R/W, R Y R4873 M2 SEQ 5 Batch ID (or 10) (ch 9‐16) ASCII‐8 1309 R/W R/W, R/W, R Y R4874 M2 SEQ 6 Batch ID (or 11) (ch 1‐8) ASCII‐8 130A R/W R/W, R/W, R Y R4875 M2 SEQ 6 Batch ID (or 11) (ch 9‐16) ASCII‐8 130B R/W R/W, R/W, R Y R4876 M3 SEQ 1 Batch ID (or 12) (ch 1‐8) ASCII‐8 130C R/W R/W, R/W, R Y R4877 M3 SEQ 1 Batch ID (or 12) (ch 9‐16) ASCII‐8 130D R/W R/W, R/W, R Y R4878 M3 SEQ 2 Batch ID (or 13) (ch 1‐8) ASCII‐8 130E R/W R/W, R/W, R Y R4879 M3 SEQ 2 Batch ID (or 13) (ch 9‐16) ASCII‐8 130F R/W R/W, R/W, R Y R4880 M3 SEQ 3 Batch ID (or 14) (ch 1‐8) ASCII‐8 1310 R/W R/W, R/W, R Y R4881 M3 SEQ 3 Batch ID (or 14) (ch 9‐16) ASCII‐8 1311 R/W R/W, R/W, R Y R

Page58 of 229 1/25/2013

Page 59: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4882 M3 SEQ 4 Batch ID (or 15) (ch 1‐8) ASCII‐8 1312 R/W R/W, R/W, R Y R4883 M3 SEQ 4 Batch ID (or 15) (ch 9‐16) ASCII‐8 1313 R/W R/W, R/W, R Y R4884 M3 SEQ 5 Batch ID (or 16) (ch 1‐8) ASCII‐8 1314 R/W R/W, R/W, R Y R4885 M3 SEQ 5 Batch ID (or 16) (ch 9‐16) ASCII‐8 1315 R/W R/W, R/W, R Y R4886 M3 SEQ 6 Batch ID (or 17) (ch 1‐8) ASCII‐8 1316 R/W R/W, R/W, R Y R4887 M3 SEQ 6 Batch ID (or 17) (ch 9‐16) ASCII‐8 1317 R/W R/W, R/W, R Y R4888 M4 SEQ 1 Batch ID (or 18) (ch 1‐8) ASCII‐8 1318 R/W R/W, R/W, R Y R4889 M4 SEQ 1 Batch ID (or 18) (ch 9‐16) ASCII‐8 1319 R/W R/W, R/W, R Y R4890 M4 SEQ 2 Batch ID (or 19) (ch 1‐8) ASCII‐8 131A R/W R/W, R/W, R Y R4891 M4 SEQ 2 Batch ID (or 19) (ch 9‐16) ASCII‐8 131B R/W R/W, R/W, R Y R4892 M4 SEQ 3 Batch ID (or 20) (ch 1‐8) ASCII‐8 131C R/W R/W, R/W, R Y R4893 M4 SEQ 3 Batch ID (or 20) (ch 9‐16) ASCII‐8 131D R/W R/W, R/W, R Y R4894 M4 SEQ 4 Batch ID (or 21) (ch 1‐8) ASCII‐8 131E R/W R/W, R/W, R Y R4895 M4 SEQ 4 Batch ID (or 21) (ch 9‐16) ASCII‐8 131F R/W R/W, R/W, R Y R4896 M4 SEQ 5 Batch ID (or 22) (Ch 1‐8) ASCII‐8 1320 R/W R/W, R/W, R Y R4897 M4 SEQ 5 Batch ID (or 22) (Ch 9‐16) ASCII‐8 1321 R/W R/W, R/W, R Y R4898 M4 SEQ 6 Batch ID (or 23) (ch 1‐8) ASCII‐8 1322 R/W R/W, R/W, R Y R4899 M4 SEQ 6 Batch ID (or 23) (ch 9‐16) ASCII‐8 1323 R/W R/W, R/W, R Y R

Prover Ascii strings (8 char)

4901 Prove Meter Product Name ASCII‐8 1325 R  R, ‐, R R4902 Prove Meter Calc Mode Text ASCII‐8 1326 R  R, ‐, R R4903 Prove Meter Batch ID (Char 1 ‐ 8) ASCII‐8 1327 R  R, ‐, R R4904 Prove Meter Batch ID (Char 9 ‐ 16) ASCII‐8 1328 R  R, ‐, R R4905 Prove Meter Serial Number ASCII‐8 1329 R  R, ‐, R R4906 Prove Meter Size ASCII‐8 132A R  R, ‐, R R4907 Prove Meter Model ASCII‐8 132B R  R, ‐, R R4908 Prove Meter ID ASCII‐8 132C R  R, ‐, R R4909 Prove Meter Tag ASCII‐8 132D R  R, ‐, R R4911 Inlet Temperature Tag ASCII‐8 132F R/W R/W, ‐, R N R4912 Outlet Temperature Tag ASCII‐8 1330 R/W R/W, ‐, R N R4913 Inlet Pressure Tag ASCII‐8 1331 R/W R/W, ‐, R N R4914 Outlet Pressure Tag ASCII‐8 1332 R/W R/W, ‐, R N R4915 Plenum Pressure Tag ASCII‐8 1333 R/W R/W, ‐, R N R4916 Prover Density/Gravity Tag ASCII‐8 1334 R/W R/W, ‐, R R4917 Prover Density Temperature Tag ASCII‐8 1335 R/W R/W, ‐, R N R4918 Prover Density Pressure Tag ASCII‐8 1336 R/W R/W, ‐, R N R

Page59 of 229 1/25/2013

Page 60: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

4920 Reserved4921 Prove Date ASCII‐8 1339 R  R, ‐, R R4922 Prove Time ASCII‐8 133A R  R, ‐, R R4923 Table Text ASCII‐8 133B R  R, ‐, R R4924 Prove Meter Product Name ASCII‐8 133C R  R, ‐, R R4925 Prove Meter ID ASCII‐8 133D R  R, ‐, R R4926 Prove Meter Serial ASCII‐8 133E R  R, ‐, R R4927 Prove Meter Size ASCII‐8 133F R  R, ‐, R R4928 Prove Meter Model ASCII‐8 1340 R  R, ‐, R R4929 Previous Meter Factor Date ASCII‐8 1341 R  R, ‐, R R4930 Previous Meter Factor Time ASCII‐8 1342 R  R, ‐, R R4931 Result String(Char 1 ‐ 8) ASCII‐8 1343 R  R, R, R R4932 Result String(Char 9 ‐ 16) ASCII‐8 1344 R  R, R, R R4933 Result String(Char 17 ‐ 24) ASCII‐8 1345 R  R, R, R R4934 Result String(Char 25 ‐ 32) ASCII‐8 1346 R  R, R, R R4935 Reason String(Char 1 ‐ 8) ASCII‐8 1347 R  R, R, R R4936 Reason String(Char 9 ‐ 16) ASCII‐8 1348 R  R, R, R R4937 Reason String(Char 17 ‐ 24) ASCII‐8 1349 R  R, R, R R4938 Reason String(Char 25 ‐ 32) ASCII‐8 134A R  R, R, R R4939 Master Meter ID ASCII‐8 134B R  R, ‐, R R4940 Master Meter Serial Number ASCII‐8 134C R  R, ‐, R R4941 Master Meter Size ASCII‐8 134D R  R, ‐, R R4942 Master Meter Model ASCII‐8 134E R  R, ‐, R R4944 Switch Bar Temperature Tag ASCII‐8 1350 R/W R/W, ‐, R N R4945 ‐ 4949 Reserved

32 Bit long integersMeter factors, Mole %s, VCFs and Cpls are interpreted as x.xxxxTotalizers are the same resolution as that displayed on LCD

Info: Registers 5n02‐5n12, 5801‐5812,5870‐5873The increment for all totalizers depends upon the ‘totalizer resolution’ setting shown in the ‘factor setup ‘menu of OmniCom. They can only be changed via the keypad entries made in the ‘password maintenance’ menu after ‘Resetting all Totalizers’

5101 Meter 1 Batch in Progress ‐ Gross Total UINT‐32 13ED R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, R, R R

Page60 of 229 1/25/2013

Page 61: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5102 Meter 1 Batch in Progress ‐ Net Total UINT‐32 13EE R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, R, R R

5103 Meter 1 Batch in Progress ‐ Mass Total UINT‐32 13EF R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, R, R R

5104 Meter 1 Batch in Progress ‐ Energy/NSV Total

UINT‐32 13F0 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, R, R R

5105 Meter 1 Cumulative Gross Total UINT‐32 13F1 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5106 Meter 1 Cumulative Net Total UINT‐32 13F2 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5107 Meter 1 Cumulative Mass Total UINT‐32 13F3 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5108 Meter 1 Cumulative Energy/NSV Total UINT‐32 13F4 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5109 Meter 1 Daily Gross Total UINT‐32 13F5 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5110 Meter 1 Daily Net Total UINT‐32 13F6 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5111 Meter 1 Daily Mass Total UINT‐32 13F7 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5112 Meter 1 Daily Energy/NSV Total UINT‐32 13F8 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

Info: Registers 5n13, 5n14, 5n15, 5n21‐5n38, 5n41These variables are stored with 4 places after the implied decimal point. i.e. 10000 is interpreted as 1.000

Page61 of 229 1/25/2013

Page 62: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5113 Meter 1 Meter Factor UINT‐32 13F9 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5114 Meter 1 Batch FWA/TWA Meter Factor UINT‐32 13FA R The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

  R, R, R R

5115 Meter 1 Daily FWA/TWA Meter Factor UINT‐32 13FB R The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

  R, ‐, R R

5116 Meter 1 Batch Preset Remaining UINT‐32 13FC R in BBLs or Klbs.   R, R, R R

5117 Meter 1 Running Product Number UINT‐32 13FD R  R, R, R R5118 Meter 1 comparator Error Counts UINT‐32 13FE R Non‐resetable error counts for 207425 and higher. 

Resetable error counts moved to 15544 for 207425 and higher.For the previous release this entry is reset when good pulses greater than the maximum good pulses.

  R, ‐, R R

5119 Meter 1 Batch Number UINT‐32 13FF R  R, ‐, R R5120 Meter 1 Raw Input Counts (500mS) UINT‐32 1400 R  R, ‐, R R5121 Meter 1 Meter Factor ‐ Product 1 UINT‐32 1401 R/W The implied decimal places is stored depending on the 

setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5122 Meter 1 Meter Factor ‐ Product 2 UINT‐32 1402 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

Page62 of 229 1/25/2013

Page 63: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5123 Meter 1 Meter Factor ‐ Product 3 UINT‐32 1403 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5124 Meter 1 Meter Factor ‐ Product 4 UINT‐32 1404 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5125 Meter 1 Meter Factor ‐ Product 5 UINT‐32 1405 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5126 Meter 1 Meter Factor ‐ Product 6 UINT‐32 1406 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5127 Meter 1 Meter Factor ‐ Product 7 UINT‐32 1407 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5128 Meter 1 Meter Factor ‐ Product 8 UINT‐32 1408 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5129 Meter 1 Meter Factor ‐ Product 9 UINT‐32 1409 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

Page63 of 229 1/25/2013

Page 64: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5130 Meter 1 Meter Factor ‐ Product 10 UINT‐32 140A R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5131 Meter 1 Meter Factor ‐ Product 11 UINT‐32 140B R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5132 Meter 1 Meter Factor ‐ Product 12 UINT‐32 140C R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5133 Meter 1 Meter Factor ‐ Product 13 UINT‐32 140D R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5134 Meter 1 Meter Factor ‐ Product 14 UINT‐32 140E R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5135 Meter 1 Meter Factor ‐ Product 15 UINT‐32 140F R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5136 Meter 1 Meter Factor ‐ Product 16 UINT‐32 1410 R/W The implied decimal places is stored depending on the setting of Modbus Register 13391. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

 R/W, ‐, R N R

5137 Meter 1 MF Change ‐ Retroactive Barrels/M3

UINT‐32 1411 R/W  R/W, ‐, R Y R

Page64 of 229 1/25/2013

Page 65: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5138 Meter 1 Batch Preset Warning Barrels/M3

UINT‐32 1412 R/W Data entered via serial link is expected to be multiplied by 10000 and need to be divided by 10000 when read this data point.

 R/W, ‐, R Y R

5139 Meter 1 Previous Day Closing Mass Total UINT‐32 1413 R   R, ‐, R R

5140 Meter 1 Previous Day Closing NSV Total UINT‐32 1414 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5141 Meter 1 Micro Motion Frequency UINT‐32 1415 R  R, ‐, R R5142 Meter 1 Micro Motion Mass Total UINT‐32 1416 R  R, ‐, R R5143 Meter 1 Hour in Progress ‐ Raw Counts UINT‐32 1417 R  R, ‐, R R5144 Meter 1 Hour in Progress ‐ Gross Total UINT‐32 1418 R The increment for the gross totalizers depends upon 

the gross totalizer resolution setting.  R, ‐, R R

5145 Meter 1 Hour in Progress ‐ Net Total UINT‐32 1419 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5146 Meter 1 Hour in Progress ‐ Mass Total UINT‐32 141A R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5147 Meter 1 Hour in Progress ‐ Energy/NSV Total

UINT‐32 141B R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5148 Meter 1 Batch in Progress ‐ Raw Counts UINT‐32 141C R  R, ‐, R R5149 Meter 1 Daily in Progress ‐ Raw Counts UINT‐32 141D R  R, ‐, R R5150 Meter 1 Previous Batch 'n' Gross Total UINT‐32 141E R The increment for the gross totalizers depends upon 

the gross totalizer resolution setting.  R, ‐, R R

5151 Meter 1 Previous Batch 'n' Net Total UINT‐32 141F R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5152 Meter 1 Previous Batch 'n' Mass Total UINT‐32 1420 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

Page65 of 229 1/25/2013

Page 66: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5153 Meter 1 Previous Batch 'n' Energy/NSV Total

UINT‐32 1421 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5154 Meter 1 Previous Day's Gross Total UINT‐32 1422 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5155 Meter 1 Previous Day's Net Total UINT‐32 1423 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5156 Meter 1 Previous Day's Mass Total UINT‐32 1424 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5157 Meter 1 Previous Day's Energy/NSV Total UINT‐32 1425 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5158 Meter 1 Current Batch ‐ Opening Gross Total

UINT‐32 1426 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5159 Meter 1 Current Batch ‐ Opening Net Total

UINT‐32 1427 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5160 Meter 1 Current Batch ‐ Opening Mass Total

UINT‐32 1428 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5161 Meter 1 Current Batch ‐ Opening Energy/NSV Total

UINT‐32 1429 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5162 Meter 1 Today's Opening Gross Total UINT‐32 142A R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5163 Meter 1 Today's Opening Net Total UINT‐32 142B R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5164 Meter 1 Today's Opening Mass Total UINT‐32 142C R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

Page66 of 229 1/25/2013

Page 67: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5165 Meter 1 Today's Opening Energy/NSV Total

UINT‐32 142D R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5166 Meter 1 Cumulative Gross Total @ Freeze Command

UINT‐32 142E R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5167 Meter 1 Cumulative Net Total @ Freeze Command

UINT‐32 142F R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5168 Meter 1 Cumulative Mass Total @ Freeze Command

UINT‐32 1430 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5169 Meter 1 Cum Energy/NSV Total @ Freeze Command

UINT‐32 1431 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5170 Meter 1 Increment Integer (500mS) ‐ Gross

UINT‐32 1432 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5171 Meter 1 Increment Integer (500mS) ‐ Net UINT‐32 1433 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5172 Meter 1 Increment Integer (500mS) ‐ Mass

UINT‐32 1434 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5173 Meter 1 Increment Integer (500mS) ‐ Energy/NSV

UINT‐32 1435 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5174 Meter 1 Previous Hourly ‐ Gross Total UINT‐32 1436 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5175 Meter 1 Previous Hourly ‐ Net Total UINT‐32 1437 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5176 Meter 1 Previous Hourly ‐ Mass Total UINT‐32 1438 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

Page67 of 229 1/25/2013

Page 68: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5177 Meter 1 Previous Hourly ‐ Energy/NSV Total

UINT‐32 1439 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5178 Meter 1 Prev Batch 'n' ‐ Opening Gross Total

UINT‐32 143A R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5179 Meter 1 Prev Batch 'n' ‐ Opening Net Total

UINT‐32 143B R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5180 Meter 1 Prev Batch 'n' ‐ Opening Mass Total

UINT‐32 143C R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5181 Meter 1 Prev Batch 'n' ‐ Opening Energy/NSV Total

UINT‐32 143D R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R   R

5182 Meter 1 Previous Day's ‐ Opening Gross Total

UINT‐32 143E R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5183 Meter 1 Previous Day's ‐ Opening Net Total

UINT‐32 143F R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5184 Meter 1 Previous Day's ‐ Opening Mass Total

UINT‐32 1440 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

5185 Meter 1 Previous Day's ‐ Opening Energy/NSV Total

UINT‐32 1441 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5186 Meter 1 Prev Batch 'n' ‐ Closing Gross Total

UINT‐32 1442 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5187 Meter 1 Prev Batch 'n' ‐ Closing Net Total UINT‐32 1443 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5188 Meter 1 Prev Batch 'n' ‐ Closing Mass Total

UINT‐32 1444 R The increment for the mass totalizers depends on the mass totalizer resolution setting.

  R, ‐, R R

Page68 of 229 1/25/2013

Page 69: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5189 Meter 1 Prev Batch 'n' ‐ Closing Energy/NSV Total

UINT‐32 1445 R The increment for the NSV totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5190 Meter 1 Previous Batch 'n' ‐ Batch Number

UINT‐32 1446 R   R, ‐, R R

5191 Meter 1 Previous Batch 'n' ‐ Product Number

UINT‐32 1447 R   R, ‐, R R

5192 Meter 1 Current Product Gross Opening Total

UINT‐32 1448 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5193 Meter 1 Current Product Gross Totalizer UINT‐32 1449 R   R, ‐, R R

5194 Meter 1 Previous Day Closing Gross Total UINT‐32 144A R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5195 Meter 1 Previous Day Closing Net Total UINT‐32 144B R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5196 Meter 1 Batch Net @ 2nd Reference Temperature

UINT‐32 144C R   R, ‐, R R

5197 Meter 1 Daily Net @ 2nd Reference Temperature

UINT‐32 144D R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5198 Meter 1 Prev Batch 'n' Net @ 2nd Ref Temperature

UINT‐32 144E R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5199 Meter 1 Prev Day's Net @ 2nd Ref Temperature

UINT‐32 144F R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5201 ‐ 5299 Meter 2 (Same as 5101 ‐ 5199) UINT‐32 1451 R/W R/W, ‐, R R5301 ‐ 5399 Meter 3 (Same as 5101 ‐ 5199) UINT‐32 14B5 R/W R/W, ‐, R R5401 ‐ 5499 Meter 4 (Same as 5101 ‐ 5199) UINT‐32 1519 R/W R/W, ‐, R R

32 Bit long integers. (Scratchpad Variables)Page69 of 229 1/25/2013

Page 70: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5501 ‐ 5599 Scratchpad Variable UINT‐32 157D R/W R/W, ‐, R R

32 Bit long integers (2nd digit 8 specifies station)

5601 Product 1 Meter1 Product Gross Opening Totalizer

UINT‐32 15E1 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5602 Product 1 Meter1 Product Gross Totalizer UINT‐32 15E2 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5603 Product 1 Meter2 Product Gross Opening Totalizer

UINT‐32 15E3 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5604 Product 1 Meter2 Product Gross Totalizer UINT‐32 15E4 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5605 Product 1 Meter3 Product Gross Opening Totalizer

UINT‐32 15E5 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5606 Product 1 Meter3 Product Gross Totalizer UINT‐32 15E6 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5607 Product 1 Meter4 Product Gross Opening Totalizer

UINT‐32 15E7 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5608 Product 1 Meter4 Product Gross Totalizer UINT‐32 15E8 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page70 of 229 1/25/2013

Page 71: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5609 Product 1 Station Product Gross Opening Totalizer

UINT‐32 15E9 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5610 Product 1 Station Product Gross Totalizer UINT‐32 15EA R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5611 Product 2 Meter1 Product Gross Opening Totalizer

UINT‐32 15EB R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5612 Product 2 Meter1 Product Gross Totalizer UINT‐32 15EC R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5613 Product 2 Meter2 Product Gross Opening Totalizer

UINT‐32 15ED R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5614 Product 2 Meter2 Product Gross Totalizer UINT‐32 15EE R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5615 Product 2 Meter3 Product Gross Opening Totalizer

UINT‐32 15EF R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5616 Product 2 Meter3 Product Gross Totalizer UINT‐32 15F0 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5617 Product 2 Meter4 Product Gross Opening Totalizer

UINT‐32 15F1 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page71 of 229 1/25/2013

Page 72: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5618 Product 2 Meter4 Product Gross Totalizer UINT‐32 15F2 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5619 Product 2 Station Product Gross Opening Totalizer

UINT‐32 15F3 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5620 Product 2 Station Product Gross Totalizer UINT‐32 15F4 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5621 Product 3 Meter1 Product Gross Opening Totalizer

UINT‐32 15F5 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5622 Product 3 Meter1 Product Gross Totalizer UINT‐32 15F6 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5623 Product 3 Meter2 Product Gross Opening Totalizer

UINT‐32 15F7 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5624 Product 3 Meter2 Product Gross Totalizer UINT‐32 15F8 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5625 Product 3 Meter3 Product Gross Opening Totalizer

UINT‐32 15F9 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5626 Product 3 Meter3 Product Gross Totalizer UINT‐32 15FA R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page72 of 229 1/25/2013

Page 73: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5627 Product 3 Meter4 Product Gross Opening Totalizer

UINT‐32 15FB R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5628 Product 3 Meter4 Product Gross Totalizer UINT‐32 15FC R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5629 Product 3 Station Product Gross Opening Totalizer

UINT‐32 15FD R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5630 Product 3 Station Product Gross Totalizer UINT‐32 15FE R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5631 Product 4 Meter1 Product Gross Opening Totalizer

UINT‐32 15FF R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5632 Product 4 Meter1 Product Gross Totalizer UINT‐32 1600 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5633 Product 4 Meter2 Product Gross Opening Totalizer

UINT‐32 1601 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5634 Product 4 Meter2 Product Gross Totalizer UINT‐32 1602 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5635 Product 4 Meter3 Product Gross Opening Totalizer

UINT‐32 1603 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page73 of 229 1/25/2013

Page 74: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5636 Product 4 Meter3 Product Gross Totalizer UINT‐32 1604 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5637 Product 4 Meter4 Product Gross Opening Totalizer

UINT‐32 1605 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5638 Product 4 Meter4 Product Gross Totalizer UINT‐32 1606 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5639 Product 4 Station Product Gross Opening Totalizer

UINT‐32 1607 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5640 Product 4 Station Product Gross Totalizer UINT‐32 1608 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5641 Product 5 Meter1 Product Gross Opening Totalizer

UINT‐32 1609 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5642 Product 5 Meter1 Product Gross Totalizer UINT‐32 160A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5643 Product 5 Meter2 Product Gross Opening Totalizer

UINT‐32 160B R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5644 Product 5 Meter2 Product Gross Totalizer UINT‐32 160C R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page74 of 229 1/25/2013

Page 75: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5645 Product 5 Meter3 Product Gross Opening Totalizer

UINT‐32 160D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5646 Product 5 Meter3 Product Gross Totalizer UINT‐32 160E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5647 Product 5 Meter4 Product Gross Opening Totalizer

UINT‐32 160F R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5648 Product 5 Meter4 Product Gross Totalizer UINT‐32 1610 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5649 Product 5 Station Product Gross Opening Totalizer

UINT‐32 1611 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5650 Product 5 Station Product Gross Totalizer UINT‐32 1612 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5651 Product 6 Meter1 Product Gross Opening Totalizer

UINT‐32 1613 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5652 Product 6 Meter1 Product Gross Totalizer UINT‐32 1614 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5653 Product 6 Meter2 Product Gross Opening Totalizer

UINT‐32 1615 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page75 of 229 1/25/2013

Page 76: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5654 Product 6 Meter2 Product Gross Totalizer UINT‐32 1616 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5655 Product 6 Meter3 Product Gross Opening Totalizer

UINT‐32 1617 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5656 Product 6 Meter3 Product Gross Totalizer UINT‐32 1618 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5657 Product 6 Meter4 Product Gross Opening Totalizer

UINT‐32 1619 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5658 Product 6 Meter4 Product Gross Totalizer UINT‐32 161A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5659 Product 6 Station Product Gross Opening Totalizer

UINT‐32 161B R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5660 Product 6 Station Product Gross Totalizer UINT‐32 161C R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5661 Product 7 Meter1 Product Gross Opening Totalizer

UINT‐32 161D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5662 Product 7 Meter1 Product Gross Totalizer UINT‐32 161E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page76 of 229 1/25/2013

Page 77: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5663 Product 7 Meter2 Product Gross Opening Totalizer

UINT‐32 161F R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5664 Product 7 Meter2 Product Gross Totalizer UINT‐32 1620 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5665 Product 7 Meter3 Product Gross Opening Totalizer

UINT‐32 1621 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5666 Product 7 Meter3 Product Gross Totalizer UINT‐32 1622 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5667 Product 7 Meter4 Product Gross Opening Totalizer

UINT‐32 1623 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5668 Product 7 Meter4 Product Gross Totalizer UINT‐32 1624 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5669 Product 7 Station Product Gross Opening Totalizer

UINT‐32 1625 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5670 Product 7 Station Product Gross Totalizer UINT‐32 1626 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5671 Product 8 Meter1 Product Gross Opening Totalizer

UINT‐32 1627 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page77 of 229 1/25/2013

Page 78: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5672 Product 8 Meter1 Product Gross Totalizer UINT‐32 1628 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5673 Product 8 Meter2 Product Gross Opening Totalizer

UINT‐32 1629 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5674 Product 8 Meter2 Product Gross Totalizer UINT‐32 162A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5675 Product 8 Meter3 Product Gross Opening Totalizer

UINT‐32 162B R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5676 Product 8 Meter3 Product Gross Totalizer UINT‐32 162C R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5677 Product 8 Meter4 Product Gross Opening Totalizer

UINT‐32 162D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5678 Product 8 Meter4 Product Gross Totalizer UINT‐32 162E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5679 Product 8 Station Product Gross Opening Totalizer

UINT‐32 162F R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5680 Product 8 Station Product Gross Totalizer UINT‐32 1630 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

Page78 of 229 1/25/2013

Page 79: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5681 Product 9 Meter1 Product Gross Opening Totalizer

UINT‐32 1631 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5682 Product 9 Meter1 Product Gross Totalizer UINT‐32 1632 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5683 Product 9 Meter2 Product Gross Opening Totalizer

UINT‐32 1633 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5684 Product 9 Meter2 Product Gross Totalizer UINT‐32 1634 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5685 Product 9 Meter3 Product Gross Opening Totalizer

UINT‐32 1635 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5686 Product 9 Meter3 Product Gross Totalizer UINT‐32 1636 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5687 Product 9 Meter4 Product Gross Opening Totalizer

UINT‐32 1637 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5688 Product 9 Meter4 Product Gross Totalizer UINT‐32 1638 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5689 Product 9 Station Product Gross Opening Totalizer

UINT‐32 1639 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

Page79 of 229 1/25/2013

Page 80: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5690 Product 9 Station Product Gross Totalizer UINT‐32 163A R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5691 Product10 Meter1 Product Gross Opening Totalizer

UINT‐32 163B R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5692 Product10 Meter1 Product Gross Totalizer

UINT‐32 163C R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5693 Product10 Meter2 Product Gross Opening Totalizer

UINT‐32 163D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5694 Product10 Meter2 Product Gross Totalizer

UINT‐32 163E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5695 Product10 Meter3 Product Gross Opening Totalizer

UINT‐32 163F R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5696 Product10 Meter3 Product Gross Totalizer

UINT‐32 1640 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5697 Product10 Meter4 Product Gross Opening Totalizer

UINT‐32 1641 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5698 Product10 Meter4 Product Gross Totalizer

UINT‐32 1642 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page80 of 229 1/25/2013

Page 81: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5699 Product10 Station Product Gross Opening Totalizer

UINT‐32 1643 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5700 Product10 Station Product Gross Totalizer

UINT‐32 1644 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5701 Product11 Meter1 Product Gross Opening Totalizer

UINT‐32 1645 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5702 Product11 Meter1 Product Gross Totalizer

UINT‐32 1646 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5703 Product11 Meter2 Product Gross Opening Totalizer

UINT‐32 1647 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5704 Product11 Meter2 Product Gross Totalizer

UINT‐32 1648 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5705 Product11 Meter3 Product Gross Opening Totalizer

UINT‐32 1649 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5706 Product11 Meter3 Product Gross Totalizer

UINT‐32 164A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5707 Product11 Meter4 Product Gross Opening Totalizer

UINT‐32 164B R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page81 of 229 1/25/2013

Page 82: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5708 Product11 Meter4 Product Gross Totalizer

UINT‐32 164C R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5709 Product11 Station Product Gross Opening Totalizer

UINT‐32 164D R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5710 Product11 Station Product Gross Totalizer

UINT‐32 164E R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5711 Product12 Meter1 Product Gross Opening Totalizer

UINT‐32 164F R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5712 Product12 Meter1 Product Gross Totalizer

UINT‐32 1650 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5713 Product12 Meter2 Product Gross Opening Totalizer

UINT‐32 1651 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5714 Product12 Meter2 Product Gross Totalizer

UINT‐32 1652 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5715 Product12 Meter3 Product Gross Opening Totalizer

UINT‐32 1653 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5716 Product12 Meter3 Product Gross Totalizer

UINT‐32 1654 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page82 of 229 1/25/2013

Page 83: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5717 Product12 Meter4 Product Gross Opening Totalizer

UINT‐32 1655 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5718 Product12 Meter4 Product Gross Totalizer

UINT‐32 1656 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5719 Product12 Station Product Gross Opening Totalizer

UINT‐32 1657 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5720 Product12 Station Product Gross Totalizer

UINT‐32 1658 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5721 Product13 Meter1 Product Gross Opening Totalizer

UINT‐32 1659 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5722 Product13 Meter1 Product Gross Totalizer

UINT‐32 165A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5723 Product13 Meter2 Product Gross Opening Totalizer

UINT‐32 165B R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5724 Product13 Meter2 Product Gross Totalizer

UINT‐32 165C R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5725 Product13 Meter3 Product Gross Opening Totalizer

UINT‐32 165D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page83 of 229 1/25/2013

Page 84: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5726 Product13 Meter3 Product Gross Totalizer

UINT‐32 165E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5727 Product13 Meter4 Product Gross Opening Totalizer

UINT‐32 165F R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5728 Product13 Meter4 Product Gross Totalizer

UINT‐32 1660 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5729 Product13 Station Product Gross Opening Totalizer

UINT‐32 1661 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5730 Product13 Station Product Gross Totalizer

UINT‐32 1662 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5731 Product14 Meter1 Product Gross Opening Totalizer

UINT‐32 1663 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5732 Product14 Meter1 Product Gross Totalizer

UINT‐32 1664 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5733 Product14 Meter2 Product Gross Opening Totalizer

UINT‐32 1665 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5734 Product14 Meter2 Product Gross Totalizer

UINT‐32 1666 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page84 of 229 1/25/2013

Page 85: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5735 Product14 Meter3 Product Gross Opening Totalizer

UINT‐32 1667 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5736 Product14 Meter3 Product Gross Totalizer

UINT‐32 1668 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5737 Product14 Meter4 Product Gross Opening Totalizer

UINT‐32 1669 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5738 Product14 Meter4 Product Gross Totalizer

UINT‐32 166A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5739 Product14 Station Product Gross Opening Totalizer

UINT‐32 166B R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5740 Product14 Station Product Gross Totalizer

UINT‐32 166C R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5741 Product15 Meter1 Product Gross Opening Totalizer

UINT‐32 166D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5742 Product15 Meter1 Product Gross Totalizer

UINT‐32 166E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5743 Product15 Meter2 Product Gross Opening Totalizer

UINT‐32 166F R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

Page85 of 229 1/25/2013

Page 86: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5744 Product15 Meter2 Product Gross Totalizer

UINT‐32 1670 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5745 Product15 Meter3 Product Gross Opening Totalizer

UINT‐32 1671 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5746 Product15 Meter3 Product Gross Totalizer

UINT‐32 1672 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5747 Product15 Meter4 Product Gross Opening Totalizer

UINT‐32 1673 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5748 Product15 Meter4 Product Gross Totalizer

UINT‐32 1674 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5749 Product15 Station Product Gross Opening Totalizer

UINT‐32 1675 R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5750 Product15 Station Product Gross Totalizer

UINT‐32 1676 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

5751 Product16 Meter1 Product Gross Opening Totalizer

UINT‐32 1677 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5752 Product16 Meter1 Product Gross Totalizer

UINT‐32 1678 R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

Page86 of 229 1/25/2013

Page 87: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5753 Product16 Meter2 Product Gross Opening Totalizer

UINT‐32 1679 R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5754 Product16 Meter2 Product Gross Totalizer

UINT‐32 167A R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5755 Product16 Meter3 Product Gross Opening Totalizer

UINT‐32 167B R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5756 Product16 Meter3 Product Gross Totalizer

UINT‐32 167C R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5757 Product16 Meter4 Product Gross Opening Totalizer

UINT‐32 167D R Non‐resettable gross totalizer by Product and Meter Run at the beginning of the batch.

  R, ‐, R R

5758 Product16 Meter4 Product Gross Totalizer

UINT‐32 167E R Non‐resettable gross totalizer by Product and Meter Run for the current batch.

  R, ‐, R R

5759 Product16 Station Product Gross Opening Totalizer

UINT‐32 167F R Non‐resettable gross totalizer by Product for the Station at the beginning of the batch.

  R, ‐, R R

5760 Product16 Station Product Gross Totalizer

UINT‐32 1680 R Non‐resettable gross totalizer by Product for the Station during the current batch.

  R, ‐, R R

32 Bit long integers

5801 Station Batch in Progress ‐ Gross Total UINT‐32 16A9 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, R, R R

Page87 of 229 1/25/2013

Page 88: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5802 Station Batch in Progress ‐ Net Total UINT‐32 16AA R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, R, R R

5803 Station Batch in Progress ‐ Mass Total UINT‐32 16AB R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, R, R R

5804 Station Batch in Progress ‐ Energy/NSV Total

UINT‐32 16AC R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, R, R R

5805 Station Cumulative Gross Total UINT‐32 16AD R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5806 Station Cumulative Net Total UINT‐32 16AE R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5807 Station Cumulative Mass Total UINT‐32 16AF R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5808 Station Cumulative Energy/NSV Total UINT‐32 16B0 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5809 Station Daily Gross Total UINT‐32 16B1 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5810 Station Daily Net Total UINT‐32 16B2 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5811 Station Daily Mass Total UINT‐32 16B3 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5812 Station Daily Energy/NSV Total UINT‐32 16B4 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5813 Station Previous Daily Closing ‐ Mass Total

UINT‐32 16B5 R   R, ‐, R R

5814 Station Line Pack Remaining UINT‐32 16B6 R  R, ‐, R R5815 Station Batch Preset Warning UINT‐32 16B7 R  R, ‐, R R

Page88 of 229 1/25/2013

Page 89: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5816 Station Batch Preset Remaining UINT‐32 16B8 R  R, R, R R5817 Station Running Product ID UINT‐32 16B9 R  R, ‐, R R5818 Station Batch Number UINT‐32 16BA R  R, ‐, R R5819 Meter1 Current Batch Size (or Sequence 

1)UINT‐32 16BB R/W  R/W, R/W, R Y R

5820 Meter1 Sequence 2 Batch Size (or Sequence 2)

UINT‐32 16BC R/W  R/W, R/W, R Y R

5821 Meter1 Sequence 3 Batch Size (or Sequence 3)

UINT‐32 16BD R/W  R/W, R/W, R Y R

5822 Meter1 Sequence 4 Batch Size (or Sequence 4)

UINT‐32 16BE R/W  R/W, R/W, R Y R

5823 Meter1 Sequence 5 Batch Size (or Sequence 5)

UINT‐32 16BF R/W  R/W, R/W, R Y R

5824 Meter1 Sequence 6 Batch Size (or Sequence 6)

UINT‐32 16C0 R/W  R/W, R/W, R Y R

5825 Meter2 Current Batch Size (or Sequence 7)

UINT‐32 16C1 R/W  R/W, R/W, R Y R

5826 Meter2 Sequence 2 Batch Size (or Sequence 8)

UINT‐32 16C2 R/W  R/W, R/W, R Y R

5827 Meter2 Sequence 3 Batch Size (or Sequence 9)

UINT‐32 16C3 R/W  R/W, R/W, R Y R

5828 Meter2 Sequence 4 Batch Size (or Sequence 10)

UINT‐32 16C4 R/W  R/W, R/W, R Y R

5829 Meter2 Sequence 5 Batch Size (or Sequence 11)

UINT‐32 16C5 R/W  R/W, R/W, R Y R

Page89 of 229 1/25/2013

Page 90: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5830 Meter2 Sequence 6 Batch Size (or Sequence 12)

UINT‐32 16C6 R/W  R/W, R/W, R Y R

5831 Meter3 Current Batch Size (or Sequence 13)

UINT‐32 16C7 R/W  R/W, R/W, R Y R

5832 Meter3 Sequence 2 Batch Size (or Sequence 14)

UINT‐32 16C8 R/W  R/W, R/W, R Y R

5833 Meter3 Sequence 3 Batch Size (or Sequence 15)

UINT‐32 16C9 R/W  R/W, R/W, R Y R

5834 Meter3 Sequence 4 Batch Size (or Sequence 16)

UINT‐32 16CA R/W  R/W, R/W, R Y R

5835 Meter3 Sequence 5 Batch Size (or Sequence 17)

UINT‐32 16CB R/W  R/W, R/W, R Y R

5836 Meter3 Sequence 6 Batch Size (or Sequence 18)

UINT‐32 16CC R/W  R/W, R/W, R Y R

5837 Meter4 Current Batch Size (or Sequence 19)

UINT‐32 16CD R/W  R/W, R/W, R Y R

5838 Meter4 Sequence 2 Batch Size (or Sequence 20)

UINT‐32 16CE R/W  R/W, R/W, R Y R

5839 Meter4 Sequence 3 Batch Size (or Sequence 21)

UINT‐32 16CF R/W  R/W, R/W, R Y R

5840 Meter4 Sequence 4 Batch Size (or Sequence 22)

UINT‐32 16D0 R/W  R/W, R/W, R Y R

5841 Meter4 Sequence 5 Batch Size (or Sequence 23)

UINT‐32 16D1 R/W  R/W, R/W, R Y R

Page90 of 229 1/25/2013

Page 91: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5842 Meter4 Sequence 6 Batch Size (or Sequence 24)

UINT‐32 16D2 R/W  R/W, R/W, R Y R

5843 Station Previous Daily Closing ‐ NSV UINT‐32 16D3 R  R, ‐, R R5844 Station Hour in Progress ‐ Gross Total UINT‐32 16D4 R The increment for the gross totalizers depends upon 

the gross totalizer resolution setting.  R, ‐, R R

5845 Station Hour in Progress ‐ Net Total UINT‐32 16D5 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5846 Station Hour in Progress ‐ Mass Total UINT‐32 16D6 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5847 Station Hour in Progress ‐ Energy/NSV Total

UINT‐32 16D7 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5848 Time in hhmmss Format UINT‐32 16D8 R  R, ‐, R R5849 Date in yymmdd Format UINT‐32 16D9 R  R, ‐, R R5850 Station Previous Batch 'n' ‐ Gross Total UINT‐32 16DA R The increment for the gross totalizers depends upon 

the gross totalizer resolution setting.  R, ‐, R R

5851 Station Previous Batch 'n' ‐ Net Total UINT‐32 16DB R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5852 Station Previous Batch 'n' ‐ Mass Total UINT‐32 16DC R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5853 Station Previous Batch 'n' ‐ Energy/NSV Total

UINT‐32 16DD R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5854 Station Previous Day's Gross Total UINT‐32 16DE R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5855 Station Previous Day's Net Total UINT‐32 16DF R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

Page91 of 229 1/25/2013

Page 92: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5856 Station Previous Day's Mass Total UINT‐32 16E0 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5857 Station Previous Day's Energy/NSV Total UINT‐32 16E1 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5858 Station Current Batch ‐ Opening Gross Total

UINT‐32 16E2 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5859 Station Current Batch ‐ Opening Net Total UINT‐32 16E3 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5860 Station Current Batch ‐ Opening Mass Total

UINT‐32 16E4 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5861 Station Current Batch ‐ Opening Energy/NSV Total

UINT‐32 16E5 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5862 Station Today's Opening Gross Total UINT‐32 16E6 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5863 Station Today's Opening Net Total UINT‐32 16E7 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5864 Station Today's Opening Mass Total UINT‐32 16E8 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5865 Station Today's Opening Energy/NSV Total

UINT‐32 16E9 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5866 Station Cum Gross Total @ Freeze Command

UINT‐32 16EA R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5867 Station Cum Net Total @ Freeze Command

UINT‐32 16EB R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

Page92 of 229 1/25/2013

Page 93: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5868 Station Cum Mass Total @ Freeze Command

UINT‐32 16EC R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5869 Station Cum Energy/NSV Total @ Freeze Command

UINT‐32 16ED R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5870 Station Increment Integer (500mS) ‐ Gross

UINT‐32 16EE R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5871 Station Increment Integer (500mS) ‐ Net UINT‐32 16EF R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5872 Station Increment Integer (500mS) ‐ Mass UINT‐32 16F0 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5873 Station Increment Integer (500mS) ‐ Energy/NSV

UINT‐32 16F1 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5874 Station Previous Hourly ‐ Gross Total UINT‐32 16F2 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5875 Station Previous Hourly ‐ Net Total UINT‐32 16F3 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5876 Station Previous Hourly ‐ Mass Total UINT‐32 16F4 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5877 Station Previous Hourly ‐ Energy/NSV Total

UINT‐32 16F5 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5878 Station Previous Batch 'n' ‐ Opening Gross Total

UINT‐32 16F6 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5879 Station Previous Batch 'n' ‐ Opening Net Total

UINT‐32 16F7 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

Page93 of 229 1/25/2013

Page 94: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5880 Station Previous Batch 'n' ‐ Opening Mass Total

UINT‐32 16F8 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5881 Station Previous Batch 'n' ‐ Opening Energy/NSV Total

UINT‐32 16F9 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5882 Station Previous Day's ‐ Opening Gross Total

UINT‐32 16FA R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5883 Station Previous Day's ‐ Opening Net Total

UINT‐32 16FB R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5884 Station Previous Day's ‐ Opening Mass Total

UINT‐32 16FC R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5885 Station Previous Day's ‐ Opening Energy/NSV Total

UINT‐32 16FD R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5886 Station Previous Batch 'n' ‐ Closing Gross Total

UINT‐32 16FE R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5887 Station Previous Batch 'n' ‐ Closing Net Total

UINT‐32 16FF R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5888 Station Previous Batch 'n' ‐ Closing Mass Total

UINT‐32 1700 R The increment for the mass totalizers depends upon the mass totalizer resolution setting.

  R, ‐, R R

5889 Station Prev Batch 'n' ‐ Closing Energy/NSV Total

UINT‐32 1701 R The increment for the NSV totalizers depends upon the NSV totalizer resolution setting.

  R, ‐, R R

5890 Station Previous Batch 'n' ‐ Batch Number UINT‐32 1702 R   R, ‐, R R

5891 Station Previous Batch 'n' ‐ Product Number

UINT‐32 1703 R   R, ‐, R R

Page94 of 229 1/25/2013

Page 95: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5892 Station Current Product Gross Opening Total

UINT‐32 1704 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5893 Station Current Product Gross Total UINT‐32 1705 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5894 Station Previous Day's ‐ Closing Gross Total

UINT‐32 1706 R The increment for the gross totalizers depends upon the gross totalizer resolution setting.

  R, ‐, R R

5895 Station Previous Day's ‐ Closing Net Total UINT‐32 1707 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5896 Station Batch Net @ 2nd Reference Temperature

UINT‐32 1708 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5897 Station Daily Net @ 2nd Reference Temperature

UINT‐32 1709 R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5898 Station Prev Batch 'n' Net @ 2nd Ref Temperature

UINT‐32 170A R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

5899 Station Prev Day's Net @ 2nd Reference Temperature

UINT‐32 170B R The increment for the net totalizers depends upon the net totalizer resolution setting.

  R, ‐, R R

32 Bit long integers (2nd digit 9 specifies prover)

5901 Prove Counts UINT‐32 170D R  R, R, R R5902 Current TDVOL UINT‐32 170E R Timer pulses accumulated between detectors 

switches, the TDVOL has an implied 6 decimal places.TDVOL is in microseconds.

  R, ‐, R R

5903 Current TDFMP UINT‐32 170F R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.It's in microseconds.

  R, ‐, R R

Page95 of 229 1/25/2013

Page 96: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5920 Total Linear Correction Factored Pulses 1st Run

UINT‐32 1720 R   R, ‐, R R

5921 Total Linear Correction Factored Pulses 2nd Run

UINT‐32 1721 R   R, ‐, R R

5922 Total Linear Correction Factored Pulses 3rd Run

UINT‐32 1722 R   R, ‐, R R

5923 Total Linear Correction Factored Pulses 4th Run

UINT‐32 1723 R   R, ‐, R R

5924 Total Linear Correction Factored Pulses 5th Run

UINT‐32 1724 R   R, ‐, R R

5925 Total Linear Correction Factored Pulses 6th Run

UINT‐32 1725 R   R, ‐, R R

5926 Total Linear Correction Factored Pulses 7th Run

UINT‐32 1726 R   R, ‐, R R

5927 Total Linear Correction Factored Pulses 8th Run

UINT‐32 1727 R   R, ‐, R R

5928 Total Linear Correction Factored Pulses 9th Run

UINT‐32 1728 R   R, ‐, R R

5929 Total Linear Correction Factored Pulses 10th Run

UINT‐32 1729 R   R, ‐, R R

5930 Net Total Since Last MF Implemented UINT‐32 172A R  R, ‐, R R5931 Prove Report Number UINT‐32 172B R  R, ‐, R R5932 Totalizer Reading Previous Prove UINT‐32 172C R  R, ‐, R R5933 Net/Mass Totalizer Reading This Prove UINT‐32 172D R  R, ‐, R R

Page96 of 229 1/25/2013

Page 97: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5934 Forward Pulses 4th Last Run UINT‐32 172E R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5935 Total Pulses 4th Last Run UINT‐32 172F R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5936 Forward Pulses 3rd Last Run UINT‐32 1730 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5937 Total Pulses 3rd Last Run UINT‐32 1731 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5938 Forward Pulses 2nd Last Run UINT‐32 1732 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5939 Total Pulses 2nd Last Run UINT‐32 1733 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5940 Forward Pulses Last Run UINT‐32 1734 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

Page97 of 229 1/25/2013

Page 98: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5941 Total Pulses Last Run UINT‐32 1735 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5942 Forward Pulses 1st Run UINT‐32 1736 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5943 Total Pulses 1st Run UINT‐32 1737 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5944 Forward Pulses 2nd Run UINT‐32 1738 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5945 Total Pulses 2nd Run UINT‐32 1739 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5946 Forward Pulses 3rd Run UINT‐32 173A R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5947 Total Pulses 3rd Run UINT‐32 173B R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

Page98 of 229 1/25/2013

Page 99: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5948 Forward Pulses 4th Run UINT‐32 173C R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5949 Total Pulses 4th Run UINT‐32 173D R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5950 Forward Pulses 5th Run UINT‐32 173E R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5951 Total Pulses 5th Run UINT‐32 173F R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5952 Forward Pulses 6th Run UINT‐32 1740 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5953 Total Pulses 6th Run UINT‐32 1741 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5954 Forward Pulses 7th Run UINT‐32 1742 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

Page99 of 229 1/25/2013

Page 100: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5955 Total Pulses 7th Run UINT‐32 1743 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5956 Forward Pulses 8th Run UINT‐32 1744 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5957 Total Pulses 8th Run UINT‐32 1745 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5958 Forward Pulses 9th Run UINT‐32 1746 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5959 Total Pulses 9th Run UINT‐32 1747 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5960 Forward Pulses 10th Run UINT‐32 1748 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5961 Total Pulses 10th Run UINT‐32 1749 R When using a compact or a small volume prover this data point has an implied 3 decimal places. On conventional pipe provers this point has 0 decimal places.

  R, R, R R

5962 Previous Prove Meter Factor UINT‐32 174A R  R, R, R R5963 Actual Meter Factor ‐ Current Prove UINT‐32 174B R  R, R, R R5964 Flowmeter Frequency 1st Run UINT‐32 174C R  R, ‐, R R

Page100 of 229 1/25/2013

Page 101: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5965 Flowmeter Frequency 2nd Run UINT‐32 174D R  R, ‐, R R5966 Flowmeter Frequency 3rd Run UINT‐32 174E R  R, ‐, R R5967 Flowmeter Frequency 4th Run UINT‐32 174F R  R, ‐, R R5968 Flowmeter Frequency 5th Run UINT‐32 1750 R  R, ‐, R R5969 Flowmeter Frequency 6th Run UINT‐32 1751 R  R, ‐, R R5970 Flowmeter Frequency 7th Run UINT‐32 1752 R  R, ‐, R R5971 Flowmeter Frequency 8th Run UINT‐32 1753 R  R, ‐, R R5972 Flowmeter Frequency 9th Run UINT‐32 1754 R  R, ‐, R R5973 Flowmeter Frequency 10th Run UINT‐32 1755 R  R, ‐, R R5974 Compact Prover TDVOL 1st Run UINT‐32 1756 R Timer pulses accumulated between detectors 

switches, the TDVOL has an implied 6 decimal places.  R, ‐, R R

5975 Compact Prover TDFMP 1st Run UINT‐32 1757 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5976 Compact Prover TDVOL 2nd Run UINT‐32 1758 R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5977 Compact Prover TDFMP 2nd Run UINT‐32 1759 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5978 Compact Prover TDVOL 3rd Run UINT‐32 175A R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5979 Compact Prover TDFMP 3rd Run UINT‐32 175B R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5980 Compact Prover TDVOL 4th Run UINT‐32 175C R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

Page101 of 229 1/25/2013

Page 102: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5981 Compact Prover TDFMP 4th Run UINT‐32 175D R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5982 Compact Prover TDVOL 5th Run UINT‐32 175E R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5983 Compact Prover TDFMP 5th Run UINT‐32 175F R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5984 Compact Prover TDVOL 6th Run UINT‐32 1760 R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5985 Compact Prover TDFMP 6th Run UINT‐32 1761 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5986 Compact Prover TDVOL 7th Run UINT‐32 1762 R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5987 Compact Prover TDFMP 7th Run UINT‐32 1763 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5988 Compact Prover TDVOL 8th Run UINT‐32 1764 R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5989 Compact Prover TDFMP 8th Run UINT‐32 1765 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

Page102 of 229 1/25/2013

Page 103: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

5990 Compact Prover TDVOL 9th Run UINT‐32 1766 R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5991 Compact Prover TDFMP 9th Run UINT‐32 1767 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5992 Compact Prover TDVOL 10th Run UINT‐32 1768 R Timer pulses accumulated between detectors switches, the TDVOL has an implied 6 decimal places.

  R, ‐, R R

5993 Compact Prover TDFMP 10th Run UINT‐32 1769 R Timer pulses accumulated between first flow pulse after each detector switches, the TDFMP has an implied 6 decimal places.

  R, ‐, R R

5994 Meter Factor ‐ Trial Prove UINT‐32 176A R The implied decimal places is stored depending on the setting of Modbus Register 13393. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

  R, ‐, R R

5995 Meter Factor ‐ Linear UINT‐32 176B R The implied decimal places is stored depending on the setting of Modbus Register 13393. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

  R, ‐, R R

5996 Meter Factor ‐ GSVp/GSVm UINT‐32 176C R The implied decimal places is stored depending on the setting of Modbus Register 13393. 10000 is interpreted as 1.0000 if 4 decimal places is selected.

  R, ‐, R R

IEEE floating point data6385 ‐ 6400 Reserved

32 Bit long integers

6105 Reserved6166 ‐ 6199 Reserved

IEEE floating point dataPage103 of 229 1/25/2013

Page 104: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7001 Analog Output 1 (0 to 100%) Float 1B59 R  R, ‐, R R7002 Analog Output 2 (0 to 100%) Float 1B5A R  R, ‐, R R7003 Analog Output 3 (0 to 100%) Float 1B5B R  R, ‐, R R7004 Analog Output 4 (0 to 100%) Float 1B5C R  R, ‐, R R

7005 Analog Output 5 (0 to 100%) Float 1B5D R  R, ‐, R R7006 Analog Output 6 (0 to 100%) Float 1B5E R  R, ‐, R R7007 Analog Output 7 (0 to 100%) Float 1B5F R  R, ‐, R R7008 Analog Output 8 (0 to 100%) Float 1B60 R  R, ‐, R R7009 Analog Output 9 (0 to 100%) Float 1B61 R  R, ‐, R R7010 Analog Output 10 (0 to 100%) Float 1B62 R  R, ‐, R R7011 Analog Output 11 (0 to 100%) Float 1B63 R  R, ‐, R R7012 Analog Output 12 (0 to 100%) Float 1B64 R  R, ‐, R R7019 Reserved7020 Reserved7021 Reserved7022 Reserved7023 Reserved7024 Reserved7025 Programmable Variable 1 Float 1B71 R/W Database  points 7025 to 7088 have been assigned as 

user variables.The value contained in these variable depends on the associated program statement which is evaluated every 500mS. You may read this variable at any time or you may write to this variable but anything you write may be overwritten by the flow computer depending on the evaluation of the statement.

 R/W, ‐, R R

7026 Programmable Variable 2 Float 1B72 R/W R/W, ‐, R R7027 Programmable Variable 3 Float 1B73 R/W R/W, ‐, R R7028 Programmable Variable 4 Float 1B74 R/W R/W, ‐, R R7029 Programmable Variable 5 Float 1B75 R/W R/W, ‐, R R7030 Programmable Variable 6 Float 1B76 R/W R/W, ‐, R R7031 Programmable Variable 7 Float 1B77 R/W R/W, ‐, R R7032 Programmable Variable 8 Float 1B78 R/W R/W, ‐, R R7033 Programmable Variable 9 Float 1B79 R/W R/W, ‐, R R7034 Programmable Variable 10 Float 1B7A R/W R/W, ‐, R R

Page104 of 229 1/25/2013

Page 105: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7035 Programmable Variable 11 Float 1B7B R/W R/W, ‐, R R7036 Programmable Variable 12 Float 1B7C R/W R/W, ‐, R R7037 Programmable Variable 13 Float 1B7D R/W R/W, ‐, R R7038 Programmable Variable 14 Float 1B7E R/W R/W, ‐, R R7039 Programmable Variable 15 Float 1B7F R/W R/W, ‐, R R7040 Programmable Variable 16 Float 1B80 R/W R/W, ‐, R R7041 Programmable Variable 17 Float 1B81 R/W R/W, ‐, R R7042 Programmable Variable 18 Float 1B82 R/W R/W, ‐, R R7043 Programmable Variable 19 Float 1B83 R/W R/W, ‐, R R7044 Programmable Variable 20 Float 1B84 R/W R/W, ‐, R R7045 Programmable Variable 21 Float 1B85 R/W R/W, ‐, R R7046 Programmable Variable 22 Float 1B86 R/W R/W, ‐, R R7047 Programmable Variable 23 Float 1B87 R/W R/W, ‐, R R7048 Programmable Variable 24 Float 1B88 R/W R/W, ‐, R R7049 Programmable Variable 25 Float 1B89 R/W R/W, ‐, R R7050 Programmable Variable 26 Float 1B8A R/W R/W, ‐, R R7051 Programmable Variable 27 Float 1B8B R/W R/W, ‐, R R7052 Programmable Variable 28 Float 1B8C R/W R/W, ‐, R R7053 Programmable Variable 29 Float 1B8D R/W R/W, ‐, R R7054 Programmable Variable 30 Float 1B8E R/W R/W, ‐, R R7055 Programmable Variable 31 Float 1B8F R/W R/W, ‐, R R7056 Programmable Variable 32 Float 1B90 R/W R/W, ‐, R R7057 Programmable Variable 33 Float 1B91 R/W R/W, ‐, R R7058 Programmable Variable 34 Float 1B92 R/W R/W, ‐, R R7059 Programmable Variable 35 Float 1B93 R/W R/W, ‐, R R7060 Programmable Variable 36 Float 1B94 R/W R/W, ‐, R R7061 Programmable Variable 37 Float 1B95 R/W R/W, ‐, R R7062 Programmable Variable 38 Float 1B96 R/W R/W, ‐, R R7063 Programmable Variable 39 Float 1B97 R/W R/W, ‐, R R7064 Programmable Variable 40 Float 1B98 R/W R/W, ‐, R R7065 Programmable Variable 41 Float 1B99 R/W R/W, ‐, R R7066 Programmable Variable 42 Float 1B9A R/W R/W, ‐, R R7067 Programmable Variable 43 Float 1B9B R/W R/W, ‐, R R7068 Programmable Variable 44 Float 1B9C R/W R/W, ‐, R R7069 Programmable Variable 45 Float 1B9D R/W R/W, ‐, R R7070 Programmable Variable 46 Float 1B9E R/W R/W, ‐, R R7071 Programmable Variable 47 Float 1B9F R/W R/W, ‐, R R7072 Programmable Variable 48 Float 1BA0 R/W R/W, ‐, R R

Page105 of 229 1/25/2013

Page 106: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7073 Programmable Variable 49 Float 1BA1 R/W R/W, ‐, R R7074 Programmable Variable 50 Float 1BA2 R/W R/W, ‐, R R7075 Programmable Variable 51 Float 1BA3 R/W R/W, ‐, R R7076 Programmable Variable 52 Float 1BA4 R/W R/W, ‐, R R7077 Programmable Variable 53 Float 1BA5 R/W R/W, ‐, R R7078 Programmable Variable 54 Float 1BA6 R/W R/W, ‐, R R7079 Programmable Variable 55 Float 1BA7 R/W R/W, ‐, R R7080 Programmable Variable 56 Float 1BA8 R/W R/W, ‐, R R7081 Programmable Variable 57 Float 1BA9 R/W R/W, ‐, R R7082 Programmable Variable 58 Float 1BAA R/W R/W, ‐, R R7083 Programmable Variable 59 Float 1BAB R/W R/W, ‐, R R7084 Programmable Variable 60 Float 1BAC R/W R/W, ‐, R R7085 Programmable Variable 61 Float 1BAD R/W R/W, ‐, R R7086 Programmable Variable 62 Float 1BAE R/W R/W, ‐, R R7087 Programmable Variable 63 Float 1BAF R/W R/W, ‐, R R7088 Programmable Variable 64 Float 1BB0 R/W R/W, ‐, R R7089 Programmable Pulse Ouput Register Float 1BB1 R/W Points 7089 to 7099 are paired with Boolean point 

variables 1089 to 1099. Numeric data placed in  7089 can be output as pulses by assigning a digital I/O point to 1089.

 R/W, ‐, R R

7090 Programmable Pulse Ouput Register Float 1BB2 R/W R/W, ‐, R R7091 Programmable Pulse Ouput Register Float 1BB3 R/W R/W, ‐, R R7092 Programmable Pulse Ouput Register Float 1BB4 R/W R/W, ‐, R R7093 Programmable Pulse Ouput Register Float 1BB5 R/W R/W, ‐, R R7094 Programmable Pulse Ouput Register Float 1BB6 R/W R/W, ‐, R R7095 Programmable Pulse Ouput Register Float 1BB7 R/W R/W, ‐, R R7096 Programmable Pulse Ouput Register Float 1BB8 R/W R/W, ‐, R R7097 Programmable Pulse Ouput Register Float 1BB9 R/W R/W, ‐, R R7098 Programmable Pulse Ouput Register Float 1BBA R/W R/W, ‐, R R7099 Programmable Pulse Ouput Register Float 1BBB R/W R/W, ‐, R R

Floating point data (2nd digit defines meter run number)

Info: Registers 7n01 ‐ 7n04  urrent Live values updated every 500mSec

7101 Meter 1 Gross Flowrate Float 1BBD R Bbl/hr   R, R, R R

Page106 of 229 1/25/2013

Page 107: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7102 Meter 1 Net Flowrate Float 1BBE R Bbl/hr   R, R, R R

7103 Meter 1 Mass Flowrate Float 1BBF R Klb/hr.   R, R, R R

7104 Meter 1 Net Standard Flowrate Float 1BC0 R Bbl/hr   R, R, R R

Info: Registers 7n05 ‐ 7n17  Current value in use now.

7105 Meter 1 Temperature Float 1BC1 R/W Current value in use Deg.F. This register may be written if input souce is 99.

 R/W, R, R R

7106 Meter 1 Pressure Float 1BC2 R/W Current value in use psig. This register may be written if input souce is 99.

 R/W, R, R R

7107 Meter 1 Propylene/Ethylene or Density in Use

Float 1BC3 R Propylene, Ethylene density in lb/ft3.   R, R, R R

7108 Meter 1 Unfactored Density Float 1BC4 R/W gm/cc.This register may be written if input source is 99.

 R/W, R, R R

7109 Meter 1 Flowing Density Float 1BC5 R gm/cc.   R, R, R R

7110 Meter 1 Density Temperature Float 1BC6 R/W Current value in use Deg.F. This register may be written if input souce is 99.

 R/W, ‐, R R

7111 Meter 1 Density Pressure Float 1BC7 R/W Current value in use psig. This register may be written if input souce is 99.

 R/W, ‐, R R

7112 Meter 1 API Flowing Float 1BC8 R  R, ‐, R R7113 Meter 1 API @60 / API @ Ref. 

TemperatureFloat 1BC9 R   R, ‐, R R

7114 Meter 1 SG Flowing Float 1BCA R  R, ‐, R RPage107 of 229 1/25/2013

Page 108: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7115 Meter 1 SG @60 Deg.F Float 1BCB R  R, R, R R7116 Meter 1 VCF Float 1BCC R  R, ‐, R R7117 Meter 1 CPL Float 1BCD R  R, ‐, R R7118 Meter 1 Current Batch Average 

TemperatureFloat 1BCE R   R, ‐, R R

7119 Meter 1 Current Batch Average Pressure Float 1BCF R  R, ‐, R R7120 Meter 1 Current Batch Avg Density Float 1BD0 R Average flowing density in gm/cc.   R, ‐, R R

7121 Meter 1 Current Batch Average Density Temperature

Float 1BD1 R Deg.F   R, ‐, R R

7122 Meter 1 Current Batch Average Density Pressure

Float 1BD2 R psig.   R, ‐, R R

7123 Meter 1 Current Batch Average API Flowing

Float 1BD3 R   R, ‐, R R

7124 Meter 1 Current Batch Average API60/API @ Ref T

Float 1BD4 R   R, ‐, R R

7125 Meter 1 Current Batch Average SG Flowing

Float 1BD5 R   R, ‐, R R

7126 Meter 1 Current Batch Average SG60/Density@ Ref.T

Float 1BD6 R   R, ‐, R R

7127 Meter 1 Current Batch Average VCF Float 1BD7 R  R, ‐, R R7128 Meter 1 Current Batch Average CPL Float 1BD8 R  R, ‐, R R7129 Meter 1 Daily Average Temperature Float 1BD9 R Deg.F   R, ‐, R R

7130 Meter 1 Daily Average Pressure Float 1BDA R psig.   R, ‐, R R

7131 Meter 1 Daily Average Density Float 1BDB R Daily average flowing density in gm/cc.   R, ‐, R R

Page108 of 229 1/25/2013

Page 109: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7132 Meter 1 Daily Average Density Temperature

Float 1BDC R Deg.F.   R, ‐, R R

7133 Meter 1 Daily Average Density Pressure Float 1BDD R psig.   R, ‐, R R

7134 Meter 1 Daily Average API Flowing Float 1BDE R  R, ‐, R R7135 Meter 1 Daily Average API60/API @ Ref.T Float 1BDF R   R, ‐, R R

7136 Meter 1 Daily Average SG Flowing Float 1BE0 R  R, ‐, R R7137 Meter 1 Daily Average SG60/Density @ 

Ref.TFloat 1BE1 R   R, ‐, R R

Info: Registers 7n38 ‐ 7n40  Current values in use now. The Data in these variables may be calculated real  me or the same data as entered elsewhere depending on the flu

7138 Meter 1 Daily Average VCF Float 1BE2 R  R, ‐, R R7139 Meter 1 Daily Average CPL Float 1BE3 R  R, ‐, R R7140 Meter 1 Current K Factor Float 1BE4 R  R, ‐, R R7141 Meter 1 Current Batch FWA K Factor Float 1BE5 R  R, ‐, R R7142 Meter 1 Daily FWA K Factor Float 1BE6 R  R, ‐, R R7143 Meter 1 Densitometer Factor in Use Float 1BE7 R  R, ‐, R R7144 Meter 1 Densitometer Factor ‐ B Float 1BE8 R/W R/W, ‐, R N R7145 Meter 1 Z Factor of Carbon Dioxide Float 1BE9 R  R, ‐, R R7146 Meter 1 Current Viscosity cSt Float 1BEA R  R, ‐, R R7147 Meter 1 LCF Coefficient b Float 1BEB R/W R/W, ‐, R N R7148 Meter 1 LCF Coefficient a Float 1BEC R/W R/W, ‐, R N R7149 Meter 1 Linear Correction Factor Float 1BED R  R, ‐, R R7150 Meter 1 LCF Coefficient c Float 1BEE R/W R/W, ‐, R N R7151 Meter 1 LCF Coefficient d Float 1BEF R/W R/W, ‐, R N R7152 Meter 1 LCF Coefficient e Float 1BF0 R/W R/W, ‐, R N R7153 Meter 1 LCF Coefficient f Float 1BF1 R/W R/W, ‐, R N R7154 Meter 1 LCF Coefficient g Float 1BF2 R/W R/W, ‐, R N R

Info: Registers 7n61, 7n62Indicates meter run gross or mass flowrate depending on which units are selected.

7161 Meter 1 Flowrate Lo‐Lim Float 1BF9 R/W R/W, ‐, R Y RPage109 of 229 1/25/2013

Page 110: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7162 Meter 1 Flowrate Hi‐Lim Float 1BFA R/W R/W, ‐, R Y R7163 Meter 1 Temp Lo‐Lim Float 1BFB R/W R/W, ‐, R Y R7164 Meter 1 Temp Hi‐Lim Float 1BFC R/W R/W, ‐, R Y R7165 Meter 1 Temp Override Float 1BFD R/W R/W, ‐, R Y R7166 Meter 1 Temp @ 4 mA Float 1BFE R/W R/W, ‐, R N R7167 Meter 1 Temp @ 20mA Float 1BFF R/W R/W, ‐, R N R7168 Meter 1 Press Lo‐Lim Float 1C00 R/W R/W, ‐, R Y R7169 Meter 1 Press Hi‐Lim Float 1C01 R/W R/W, ‐, R Y R7170 Meter 1 Press Override Float 1C02 R/W R/W, ‐, R Y R7171 Meter 1 Press @ 4 mA Float 1C03 R/W R/W, ‐, R N R7172 Meter 1 Press @ 20mA Float 1C04 R/W R/W, ‐, R N R7173 Meter 1 Gravity/Density Lo‐Lim Float 1C05 R/W R/W, ‐, R Y R7174 Meter 1 Gravity/Density Hi‐Lim Float 1C06 R/W R/W, ‐, R Y R7175 Meter 1 Gravity/Density Override Float 1C07 R/W R/W, ‐, R Y R7176 Meter 1 Gravity/Density @ 4 mA Float 1C08 R/W R/W, ‐, R N R7177 Meter 1 Gravity/Density @ 20mA Float 1C09 R/W R/W, ‐, R N R7178 Meter 1 Density Temp Lo‐Limit Float 1C0A R/W R/W, ‐, R Y R7179 Meter 1 Density Temp Hi‐Limit Float 1C0B R/W R/W, ‐, R Y R7180 Meter 1 Density Temp Override Float 1C0C R/W R/W, ‐, R Y R7181 Meter 1 Density Temp @ 4 mA Float 1C0D R/W R/W, ‐, R N R7182 Meter 1 Density Temp @ 20mA Float 1C0E R/W R/W, ‐, R N R7183 Meter 1 Density Pres Lo‐Limit Float 1C0F R/W R/W, ‐, R Y R7184 Meter 1 Density Pres Hi‐Limit Float 1C10 R/W R/W, ‐, R Y R7185 Meter 1 Density Pres Override Float 1C11 R/W R/W, ‐, R Y R7186 Meter 1 Density Pres @ 4 mA Float 1C12 R/W R/W, ‐, R N R7187 Meter 1 Density Pres @ 20mA Float 1C13 R/W R/W, ‐, R N R7188 Meter 1 Density Correction Factor A Float 1C14 R/W R/W, ‐, R N R7189 Meter 1 Dens Const 1 (K0/K0/D0/K0) Float 1C15 R/W R/W, ‐, R N R7190 Meter 1 Dens Const 2 (K1/K1/T0/K1) Float 1C16 R/W R/W, ‐, R N R7191 Meter 1 Dens Const 3 (K2/K2/K/K2) Float 1C17 R/W R/W, ‐, R N R7192 Meter 1 Dens Const 4 

(K18/Tcal/Tcoef/K18)Float 1C18 R/W  R/W, ‐, R N R

7193 Meter 1 Dens Const 5 (K19/Kt1/Tcal/K19) Float 1C19 R/W  R/W, ‐, R N R

Page110 of 229 1/25/2013

Page 111: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7194 Meter 1 Dens Const 6 (K20A/Kt2/Pcoef/K3)

Float 1C1A R/W  R/W, ‐, R N R

7195 Meter 1 Dens Const 7 (K20B/Kt3/Pcal/K4) Float 1C1B R/W  R/W, ‐, R N R

7196 Meter 1 Dens Const 8 (K21A/Pc/CalGasConstant)

Float 1C1C R/W  R/W, ‐, R N R

7197 Meter 1 Dens Const 9 (K21B/Kp1/SpecificHeatRatio)

Float 1C1D R/W  R/W, ‐, R N R

7198 Meter 1 Dens Const 10 (Kr/Kp2) Float 1C1E R/W R/W, ‐, R N R7199 Meter 1 Dens Const 11 (Kj/Kp3) Float 1C1F R/W R/W, ‐, R N R

7201 ‐ 7299 Meter 2 (Same as 7101 ‐ 7199) Float 1C21 R/W R/W, ‐, R R7301 ‐ 7399 Meter 3 (Same as 7101 ‐ 7199) Float 1C85 R/W R/W, ‐, R R7401 ‐ 7499 Meter 4 (Same as 7101 ‐ 7199) Float 1CE9 R/W R/W, ‐, R R

Floating point data. (Scratchpad Variables)

7501 ‐ 7599 Scratchpad Variable Float 1D4D R/W R/W, ‐, R R

Floating point data

Info: Registers  7640‐7643,7650‐7653,7660‐7663,7670‐7673,7680‐7683These variables represent the incremental flow which is accumulated each 500mSec calculation cycle in float format (also see 5n70 registers for integer format)

Info: Registers  7634‐7636,7644‐7646,7654‐7656,7664‐7666,7674‐7676Flowing variables are snapshot and stored here when Leak Detection Freeze command (1760) is received. (also see points 5n66) 

7601 PID 1 Local Setpoint Float 1DB1 R  R, ‐, R R7602 PID 1 Primary Setpoint Used Float 1DB2 R  R, ‐, R R7603 PID 1 Remote Setpoint Float 1DB3 R/W R/W, ‐, R R7604 PID 1 Output % Float 1DB4 R/W R/W, ‐, R R7605 PID 1 Secondary Setpoint Float 1DB5 R/W R/W, ‐, R R7606 PID 2 Local Setpoint Float 1DB6 R  R, ‐, R R7607 PID 2 Primary Setpoint Used Float 1DB7 R  R, ‐, R R

Page111 of 229 1/25/2013

Page 112: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7608 PID 2 Remote Setpoint Float 1DB8 R/W R/W, ‐, R R7609 PID 2 Output % Float 1DB9 R/W R/W, ‐, R R7610 PID 2 Secondary Setpoint Float 1DBA R/W R/W, ‐, R R7611 PID 3 Local Setpoint Float 1DBB R  R, ‐, R R7612 PID 3 Primary Setpoint Used Float 1DBC R  R, ‐, R R7613 PID 3 Remote Setpoint Float 1DBD R/W R/W, ‐, R R7614 PID 3 Output % Float 1DBE R/W R/W, ‐, R R7615 PID 3 Secondary Setpoint Float 1DBF R/W R/W, ‐, R R7616 PID 4 Local Setpoint Float 1DC0 R  R, ‐, R R7617 PID 4 Primary Setpoint Used Float 1DC1 R  R, ‐, R R7618 PID 4 Remote Setpoint Float 1DC2 R/W R/W, ‐, R R7619 PID 4 Output % Float 1DC3 R/W R/W, ‐, R R7620 PID 4 Secondary Setpoint Float 1DC4 R/W R/W, ‐, R R7621 Reserved7622 Reserved7623 Reserved7624 Meter 1 Equilibrium Pressure Float 1DC8 R psig.   R, ‐, R R

7625 Meter 2 Equilibrium Pressure Float 1DC9 R psig.   R, ‐, R R

7626 Meter 3 Equilibrium Pressure Float 1DCA R psig.   R, ‐, R R

7627 Meter 4 Equilibrium Pressure Float 1DCB R psig.   R, ‐, R R

7628 Prover Equilibrium Pressure Float 1DCC R psig.   R, ‐, R R

7629 Meter 1 Vapor Pressure @ 100 Deg.F Float 1DCD R  R, ‐, R R7630 Meter 2 Vapor Pressure @ 100 Deg.F Float 1DCE R  R, ‐, R R7631 Meter 3 Vapor Pressure @ 100 Deg.F Float 1DCF R  R, ‐, R R7632 Meter 4 Vapor Pressure @ 100 Deg.F Float 1DD0 R  R, ‐, R R7633 Prover Vapor Pressure @ 100 Deg.F Float 1DD1 R  R, ‐, R R7634 Meter 1 Temperature at Freeze 

CommandFloat 1DD2 R   R, ‐, R R

Page112 of 229 1/25/2013

Page 113: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7635 Meter 1 Pressure at Freeze Command Float 1DD3 R  R, ‐, R R7636 Meter 1 Density at Freeze Command Float 1DD4 R  R, ‐, R R7637 Reserved7638 Reserved7639 Reserved7640 Meter 1 Gross Increment per 500 mS Float 1DD8 R  R, ‐, R R7641 Meter 1 Net Increment per 500mS Float 1DD9 R  R, ‐, R R7642 Meter 1 Mass Increment per 500mS Float 1DDA R  R, ‐, R R7643 Meter 1 Energy or NSV Increment per 

500mSFloat 1DDB R   R, ‐, R R

7644 Meter 2 Temperature at Freeze Command

Float 1DDC R   R, ‐, R R

7645 Meter 2 Pressure at Freeze Command Float 1DDD R  R, ‐, R R7646 Meter 2 Density at Freeze Command Float 1DDE R  R, ‐, R R7647 Reserved7648 Reserved7649 Reserved7650 Meter 2 Gross Increment per 500mS Float 1DE2 R  R, ‐, R R7651 Meter 2 Net Increment per 500mS Float 1DE3 R  R, ‐, R R7652 Meter 2 Mass Increment per 500mS Float 1DE4 R  R, ‐, R R7653 Meter 2 Energy or NSV Increment per 

500mSFloat 1DE5 R   R, ‐, R R

7654 Meter 3 Temperature at Freeze Command

Float 1DE6 R   R, ‐, R R

7655 Meter 3 Pressure at Freeze Command Float 1DE7 R  R, ‐, R R7656 Meter 3 Density at Freeze Command Float 1DE8 R  R, ‐, R R7657 Reserved7658 Reserved7659 Reserved7660 Meter 3 Gross Increment per 500mS Float 1DEC R  R, ‐, R R7661 Meter 3 Net Increment per 500mS Float 1DED R  R, ‐, R R7662 Meter 3 Mass Increment per 500mS Float 1DEE R  R, ‐, R R7663 Meter 3 Energy or NSV Increment per 

500mSFloat 1DEF R   R, ‐, R R

Page113 of 229 1/25/2013

Page 114: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7664 Meter 4 Temperature at Freeze Command

Float 1DF0 R   R, ‐, R R

7665 Meter 4 Pressure at Freeze Command Float 1DF1 R  R, ‐, R R7666 Meter 4 Density at Freeze Command Float 1DF2 R  R, ‐, R R7667 Reserved7668 Reserved7669 Reserved7670 Meter 4 Gross Increment per 500mS Float 1DF6 R  R, ‐, R R7671 Meter 4 Net Increment per 500mS Float 1DF7 R  R, ‐, R R7672 Meter 4 Mass Increment per 500mS Float 1DF8 R  R, ‐, R R7673 Meter 4 Energy or NSV Increment per 

500mSFloat 1DF9 R   R, ‐, R R

7674 Station Temperature at Freeze Command Float 1DFA R  R, ‐, R R7675 Station Pressure at Freeze Command Float 1DFB R  R, ‐, R R7676 Station Density at Freeze Command Float 1DFC R  R, ‐, R R7677 Reserved7678 Reserved7679 Reserved7680 Station Gross Increment per 500mS Float 1E00 R  R, ‐, R R7681 Station Net Increment per 500mS Float 1E01 R  R, ‐, R R7682 Station Mass Increment per 500mS Float 1E02 R  R, ‐, R R7683 Station Energy or NSV Increment per 

500mSFloat 1E03 R   R, ‐, R R

7684 ‐ 7698 Reserved7699 2nd Reference Temperature Float 1E13 R  R, ‐, R R

IEEE floating point data

7701 Analog Input 1 (0 to 100%) Float 1E15 R  R, ‐, R R7702 Analog Input 2 (0 to 100%) Float 1E16 R  R, ‐, R R7703 Analog Input 3 (0 to 100%) Float 1E17 R  R, ‐, R R7704 Analog Input 4 (0 to 100%) Float 1E18 R  R, ‐, R R7705 Analog Input 5 (0 to 100%) Float 1E19 R  R, ‐, R R7706 Analog Input 6 (0 to 100%) Float 1E1A R  R, ‐, R R7707 Analog Input 7 (0 to 100%) Float 1E1B R  R, ‐, R R7708 Analog Input 8 (0 to 100%) Float 1E1C R  R, ‐, R R

Page114 of 229 1/25/2013

Page 115: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7709 Analog Input 9 (0 to 100%) Float 1E1D R  R, ‐, R R7710 Analog Input 10 (0 to 100%) Float 1E1E R  R, ‐, R R7711 Analog Input 11 (0 to 100%) Float 1E1F R  R, ‐, R R7712 Analog Input 12 (0 to 100%) Float 1E20 R  R, ‐, R R7713 Analog Input 13 (0 to 100%) Float 1E21 R  R, ‐, R R7714 Analog Input 14 (0 to 100%) Float 1E22 R  R, ‐, R R7715 Analog Input 15 (0 to 100%) Float 1E23 R  R, ‐, R R7716 Analog Input 16 (0 to 100%) Float 1E24 R  R, ‐, R R7717 Analog Input 17 (0 to 100%) Float 1E25 R  R, ‐, R R7718 Analog Input 18 (0 to 100%) Float 1E26 R  R, ‐, R R7719 Analog Input 19 (0 to 100%) Float 1E27 R  R, ‐, R R7720 Analog Input 20 (0 to 100%) Float 1E28 R  R, ‐, R R7721 Analog Input 21 (0 to 100%) Float 1E29 R  R, ‐, R R7722 Analog Input 22 (0 to 100%) Float 1E2A R  R, ‐, R R7723 Analog Input 23 (0 to 100%) Float 1E2B R  R, ‐, R R7724 Analog Input 24 (0 to 100%) Float 1E2C R  R, ‐, R R7725 ‐ 7770 Reserved7779 ‐ 7782 Reserved7783 Meter 1 Seq 2 Batch Size Float 1E67 R/W Read or write sequence #2 batch size in floating point 

format. R/W, ‐, R R

7784 Meter 2 Seq 2 Batch Size Float 1E68 R/W Read or write sequence #2 batch size in floating point format.

 R/W, ‐, R R

7785 Meter 3 Seq 2 Batch Size Float 1E69 R/W Read or write sequence #2 batch size in floating point format.

 R/W, ‐, R R

7786 Meter 4 Seq 2 Batch Size Float 1E6A R/W Read or write sequence #2 batch size in floating point format.

 R/W, ‐, R R

7787 Meter 1 Seq 1 Batch Size Float 1E6B R/W Read or write sequence #1 batch size in floating point format.

 R/W, ‐, R R

7788 Meter 2 Seq 1 Batch Size Float 1E6C R/W Read or write sequence #1 batch size in floating point format.

 R/W, ‐, R R

Page115 of 229 1/25/2013

Page 116: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7789 Meter 3 Seq 1 Batch Size Float 1E6D R/W Read or write sequence #1 batch size in floating point format.

 R/W, ‐, R R

7790 Meter 4 Seq 1 Batch Size Float 1E6E R/W Read or write sequence #1 batch size in floating point format.

 R/W, ‐, R R

7791 Meter 1 Batch Preset Warning Float 1E6F R/W Read or write batch preset warning in floating point format.

 R/W, ‐, R R

7792 Meter 2 Batch Preset Warning Float 1E70 R/W Read or write batch preset warning in floating point format.

 R/W, ‐, R R

7793 Meter 3 Batch Preset Warning Float 1E71 R/W Read or write batch preset warning in floating point format.

 R/W, ‐, R R

7794 Meter 4 Batch Preset Warning Float 1E72 R/W Read or write batch preset warning in floating point format.

 R/W, ‐, R R

7795 Station Batch Preset Warning Float 1E73 R/W Read or write batch preset warning in floating point format.

 R/W, ‐, R R

7796 Meter 1 Meter Factor Float 1E74 R/W Read or write current Meter Factor in floating point format.

 R/W, ‐, R R

7797 Meter 2 Meter Factor Float 1E75 R/W Read or write current Meter Factor in floating point format.

 R/W, ‐, R R

7798 Meter 3 Meter Factor Float 1E76 R/W Read or write current Meter Factor in floating point format.

 R/W, ‐, R R

7799 Meter 4 Meter Factor Float 1E77 R/W Read or write current Meter Factor in floating point format.

 R/W, ‐, R R

Floating point data (2nd digit 8 defines station or product related data)

7801 Station Gross Flowrate Float 1E79 R Bbl/hr.   R, ‐, R R

Page116 of 229 1/25/2013

Page 117: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7802 Station Net Flowrate Float 1E7A R Bbl/hr.   R, ‐, R R

7803 Station Mass Flowrate Float 1E7B R Klb/hr.   R, ‐, R R

7804 Station NSV Flowrate Float 1E7C R Bbl/hr.   R, ‐, R R

7805 Station Gravity/Density Float 1E7D R  R, ‐, R R7806 Station Density Temperature Float 1E7E R/W Current value in use Deg.F. This register may be 

written if input souce is 99. R/W, ‐, R R

7807 Station Density Pressure Float 1E7F R/W Current value in use psig. This register may be written if input souce is 99.

 R/W, ‐, R R

7808 Switch Bar Temperature Float 1E80 R/W Current value in use Deg.F. This register may be written if input souce is 99.

 R/W, R, R R

7809 Auxiliary Input 1 Float 1E81 R/W This register may be written if input source is 99.  R/W, ‐, R R

7810 Auxiliary Input 2 Float 1E82 R/W This register may be written if input source is 99.  R/W, ‐, R R

7811 Auxiliary Input 3 Float 1E83 R/W This register may be written if input source is 99.  R/W, ‐, R R

7812 Auxiliary Input 4 Float 1E84 R/W This register may be written if input source is 99.  R/W, ‐, R R

7813 Current Time HHMMSS Float 1E85 R  R, ‐, R R7814 Current Date YYMMDD Float 1E86 R  R, ‐, R R7816 Reserved7821 Product 1  API Override/Alpha/Vapor 

PressureFloat 1E8D R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

Page117 of 229 1/25/2013

Page 118: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Product 1 Equilibrium Pressure R/W If product algorithm is selected as NGL (code 40).  R/W, ‐, R Y R

7822 Product 1  SG  Override Float 1E8E R/W R/W, ‐, R Y R7823 Product 2  API Override/Alpha/Vapor 

PressureFloat 1E8F R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

Product 2 Equilibrium Pressure R/W If product algorithm is selected as NGL (code 40).  R/W, ‐, R Y R

7824 Product 2  SG  Override Float 1E90 R/W R/W, ‐, R Y R7825 Product 3  API Override/Alpha/Vapor 

PressureFloat 1E91 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7826 Product 3  SG  Override Float 1E92 R/W R/W, ‐, R Y R7827 Product 4  API Override/Alpha/Vapor 

PressureFloat 1E93 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7828 Product 4  SG  Override Float 1E94 R/W R/W, ‐, R Y R

Page118 of 229 1/25/2013

Page 119: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7829 Product 5  API Override/Alpha/Vapor Pressure

Float 1E95 R/W If product algorithm is selected as table 24C or special liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7830 Product 5  SG  Override Float 1E96 R/W R/W, ‐, R Y R7831 Product 6  API Override/Alpha/Vapor 

PressureFloat 1E97 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7832 Product 6  SG  Override Float 1E98 R/W R/W, ‐, R Y R7833 Product 7  API Override/Alpha/Vapor 

PressureFloat 1E99 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7834 Product 7  SG  Override Float 1E9A R/W R/W, ‐, R Y R7835 Product 8  API Override/Alpha/Vapor 

PressureFloat 1E9B R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7836 Product 8  SG  Override Float 1E9C R/W R/W, ‐, R Y R

Page119 of 229 1/25/2013

Page 120: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7837 Product 9  API Override/Alpha/Vapor Pressure

Float 1E9D R/W If product algorithm is selected as table 24C or special liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7838 Product 9  SG  Override Float 1E9E R/W R/W, ‐, R Y R7839 Product 10  API Override/Alpha/Vapor 

PressureFloat 1E9F R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7840 Product 10 SG  Override Float 1EA0 R/W R/W, ‐, R Y R7841 Product 11  API Override/Alpha/Vapor 

PressureFloat 1EA1 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7842 Product 11 SG  Override Float 1EA2 R/W R/W, ‐, R Y R7843 Product 12 API Override/Alpha/Vapor 

PressureFloat 1EA3 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7844 Product 12 SG  Override Float 1EA4 R/W R/W, ‐, R Y R

Page120 of 229 1/25/2013

Page 121: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7845 Product 13  API Override/Alpha/Vapor Pressure

Float 1EA5 R/W If product algorithm is selected as table 24C or special liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7846 Product 13 SG  Override Float 1EA6 R/W R/W, ‐, R Y R7847 Product 14  API Override/Alpha/Vapor 

PressureFloat 1EA7 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7848 Product 14 SG  Override Float 1EA8 R/W R/W, ‐, R Y R7849 Product 15  API Override/Alpha/Vapor 

PressureFloat 1EA9 R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7850 Product 15 SG  Override Float 1EAA R/W R/W, ‐, R Y R7851 Product 16  API Override/Alpha/Vapor 

PressureFloat 1EAB R/W If product algorithm is selected as table 24C or special 

liquid of API 11.1 2002, this point will be pointed to Alpha of this product.If product algorithm is selected as GPA TP16 or table 23/24E, this point will be pointed to vapor pressure.Otherwise this point will be pointed to API Override.

 R/W, ‐, R Y R

7852 Product 16 SG  Override Float 1EAC R/W R/W, ‐, R Y R7853 Station Flowrate Low‐Limit Float 1EAD R/W R/W, ‐, R Y R7854 Station Flowrate High‐Limit Float 1EAE R/W R/W, ‐, R Y R

Page121 of 229 1/25/2013

Page 122: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7855 Run Switching Threshold Low 1 Float 1EAF R/W R/W, ‐, R N R7856 Run Switching Threshold High 1 Float 1EB0 R/W R/W, ‐, R N R7857 Run Switching Threshold Low 2 Float 1EB1 R/W R/W, ‐, R N R7858 Run Switching Threshold High 2 Float 1EB2 R/W R/W, ‐, R N R7859 Run Switching Threshold Low 3 Float 1EB3 R/W R/W, ‐, R N R7860 Run Switching Threshold High 3 Float 1EB4 R/W R/W, ‐, R N R7861 Station Pressure Low‐Limit Float 1EB5 R/W R/W, ‐, R Y R7862 Station Pressure High‐Limit Float 1EB6 R/W R/W, ‐, R Y R7863 Station Pressure Override Float 1EB7 R/W R/W, ‐, R Y R7864 Station Pressure @ 4 mA Float 1EB8 R/W R/W, ‐, R N R7865 Station Pressure @ 20mA Float 1EB9 R/W R/W, ‐, R N R7866 Station Gravity/Density Low‐Limit Float 1EBA R/W R/W, ‐, R Y R7867 Station Gravity/Density High‐Limit Float 1EBB R/W R/W, ‐, R Y R7868 Station Gravity/Density Override Float 1EBC R/W R/W, ‐, R Y R7869 Station Gravity/Density @ 4 mA Float 1EBD R/W R/W, ‐, R N R7870 Station Gravity/Density @ 20mA Float 1EBE R/W R/W, ‐, R N R7871 Station Density Temp Low‐Limit Float 1EBF R/W R/W, ‐, R Y R7872 Station Density Temp High‐Limit Float 1EC0 R/W R/W, ‐, R Y R7873 Station Density Temp Override Float 1EC1 R/W R/W, ‐, R Y R7874 Station Density Temp @ 4 mA Float 1EC2 R/W R/W, ‐, R N R7875 Station Density Temp @ 20mA Float 1EC3 R/W R/W, ‐, R N R7876 Station Density Correction Factor Float 1EC4 R/W R/W, ‐, R N R7877 Station Dens Const 1 (K0/K0/D0/K0) Float 1EC5 R/W R/W, ‐, R N R7878 Station Dens Const 2 (K1/K1/T0/K1) Float 1EC6 R/W R/W, ‐, R N R7879 Station Dens Const 3 (K2/K2/K/K2) Float 1EC7 R/W R/W, ‐, R N R7880 Station Dens Const 4 (K18/Tc/Tcoef/K18) Float 1EC8 R/W  R/W, ‐, R N R

7881 Station Dens Const 5 (K19/Kt1/Tcal/K19) Float 1EC9 R/W  R/W, ‐, R N R

7882 Station Dens Const 6 (K20A/Kt2/Pcoef/K3)

Float 1ECA R/W  R/W, ‐, R N R

7883 Station Dens Const 7 (K20B/Kt3/Pcal/K4) Float 1ECB R/W  R/W, ‐, R N R

7884 Station Dens Const 8 (K21A/Pc/K5) Float 1ECC R/W R/W, ‐, R N RPage122 of 229 1/25/2013

Page 123: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7885 Station Dens Const 9 (K21B/Kp1/G) Float 1ECD R/W R/W, ‐, R N R7886 Station Dens Const 10 (Kr/Kp2) Float 1ECE R/W R/W, ‐, R N R7887 Station Dens Const 11 (Kj/Kp3) Float 1ECF R/W R/W, ‐, R N R7888 Weight of Water lbm/BBL or Kg/M3 Float 1ED0 R/W R/W, ‐, R N R7889 Gravity Rate of Change Float 1ED1 R/W R/W, ‐, R N R7890 Line Pack Delay (Net Barrels/M3) Float 1ED2 R/W R/W, ‐, R N R7891 Atmospheric Pressure Float 1ED3 R/W R/W, ‐, R N R7892 Base Temperature Float 1ED4 R/W R/W, ‐, R N R7893 Gram/CC to Lb/Ft3 Float 1ED5 R/W R/W, ‐, R N R7894 Base Pressure Float 1ED6 R/W R/W, ‐, R N R7896 Startup Flow of Auto Prove Float 1ED8 R/W R/W, ‐, R Y R7897 Max Flow Between Proves for Auto Prove Float 1ED9 R/W  R/W, ‐, R Y R

7898 Min Flow Rate Change of Auto Prove Float 1EDA R/W R/W, ‐, R Y R7899 Delta Flow Rate(Flow Unstable Check) 

ProveFloat 1EDB R/W  R/W, ‐, R Y R

Floating point (Prover related data)

7901 Inlet Temperature Float 1EDD R  R, ‐, R R7902 Outlet Temperature Float 1EDE R  R, ‐, R R7903 Prover Temperature in Use Float 1EDF R  R, R, R R7904 Inlet Pressure Float 1EE0 R  R, ‐, R R7905 Outlet Pressure Float 1EE1 R  R, ‐, R R7906 Prover Pressure in Use Float 1EE2 R  R, R, R R7907 Plenum Pressure Float 1EE3 R  R, ‐, R R7908 Prover Run Time Float 1EE4 R  R, ‐, R R7909 Master Prove Volume Float 1EE5 R  R, ‐, R R7910 Tester Meter Volume Float 1EE6 R  R, ‐, R R7911 Calculated Plenum Pressure Float 1EE7 R  R, ‐, R R7912 Prover Api/Sg/Density Float 1EE8 R  R, ‐, R R7913 Prover Density Temperature Float 1EE9 R  R, ‐, R R7914 Prover Density Pressure Float 1EEA R  R, ‐, R R7915 Prover Uncorrected Density Float 1EEB R  R, ‐, R R7916 Prover Density Float 1EEC R  R, R, R R7917 Invar Rod Temperature Float 1EED R/W R/W, ‐, R Y R7918 Overtravel (Barrels/M3) Float 1EEE R/W R/W, ‐, R N R

Page123 of 229 1/25/2013

Page 124: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7919 Prover Volume Barrels/M3 Float 1EEF R/W R/W, R , R N R7920 Prover Diameter Inches/mm Float 1EF0 R/W R/W, ‐, R N R7921 Prover Wall Thickness Inches/mm Float 1EF1 R/W R/W, ‐, R N R7922 Mod of Elastic Property Float 1EF2 R/W R/W, ‐, R N R7923 Coeff. of Cubic Expansion Float 1EF3 R/W R/W, ‐, R N R7924 Base Pressure Float 1EF4 R/W R/W, ‐, R N R7925 Sample Delta Float 1EF5 R/W R/W, ‐, R Y R7926 Temperature Deviation Float 1EF6 R/W R/W, ‐, R Y R7927 Count Deviation % Float 1EF7 R/W R/W, ‐, R Y R7928 Acceptable Meter Factor Dev % Float 1EF8 R/W R/W, ‐, R Y R7929 Inlet Temperature Low Limit Float 1EF9 R/W R/W, ‐, R Y R7930 Inlet Temperature High Limit Float 1EFA R/W R/W, ‐, R Y R7931 Inlet Temperature Override Float 1EFB R/W R/W, ‐, R Y R7932 Inlet Temperature @ 4 mA Float 1EFC R/W R/W, ‐, R N R7933 Inlet Temperature @ 20mA Float 1EFD R/W R/W, ‐, R N R7934 Outlet Temperature Low Limit Float 1EFE R/W R/W, ‐, R Y R7935 Outlet Temperature High Limit Float 1EFF R/W R/W, ‐, R Y R7936 Outlet Temperature Override Float 1F00 R/W R/W, ‐, R Y R7937 Outlet Temperature @ 4 mA Float 1F01 R/W R/W, ‐, R N R7938 Outlet Temperature @ 20mA Float 1F02 R/W R/W, ‐, R N R7939 Inlet Pressure Low Limit Float 1F03 R/W R/W, ‐, R Y R7940 Inlet Pressure High Limit Float 1F04 R/W R/W, ‐, R Y R7941 Inlet Pressure Override Float 1F05 R/W R/W, ‐, R Y R7942 Inlet Pressure @ 4 mA Float 1F06 R/W R/W, ‐, R N R7943 Inlet Pressure @ 20mA Float 1F07 R/W R/W, ‐, R N R7944 Outlet Pressure Low Limit Float 1F08 R/W R/W, ‐, R Y R7945 Outlet Pressure High Limit Float 1F09 R/W R/W, ‐, R Y R7946 Outlet Pressure Override Float 1F0A R/W R/W, ‐, R Y R7947 Outlet Pressure @ 4 mA Float 1F0B R/W R/W, ‐, R N R7948 Outlet Pressure @ 20mA Float 1F0C R/W R/W, ‐, R N R7949 Flow Rate %Change Threshold Float 1F0D R/W R/W, ‐, R Y R7950 Linear Thermal Coeff Float 1F0E R/W R/W, ‐, R N R7951 Plenum Pressure Constant Float 1F0F R/W R/W, ‐, R N R7952 Plenum Deadband % Float 1F10 R/W R/W, ‐, R Y R7953 Plenum Pressure @  4mA Float 1F11 R/W R/W, ‐, R N R7954 Plenum Pressure @ 20mA Float 1F12 R/W R/W, ‐, R N R7955 Prover Volume Upstream Float 1F13 R/W R/W, ‐, R N R7956 SG60/DEN15 @ MF Implemented Float 1F14 R  R, ‐, R R

Page124 of 229 1/25/2013

Page 125: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7957 Temperature @ MF Implemented Float 1F15 R  R, ‐, R R7958 Pressure @ MF Implemented Float 1F16 R  R, ‐, R R7959 Prover Volume Float 1F17 R  R, ‐, R R7960 Diameter Inches/Millimeters Float 1F18 R/W R/W, ‐, R N R7961 Wall Thickness Float 1F19 R/W R/W, ‐, R N R7962 Elasticity Float 1F1A R/W R/W, ‐, R N R7963 Cubic Expansion Factor Float 1F1B R/W R/W, ‐, R N R7964 K Factor (Average Runs) Float 1F1C R  R, ‐, R R7965 Master Meter K Factor Float 1F1D R  R, ‐, R R7966 Flowrate @ Meter Factor Implemented Float 1F1E R  R, R, R R7967 Avg Meter Temperature Last ‐ 3 Run Float 1F1F R  R, R, R R7968 Avg Meter Pressure Last ‐ 3 Run Float 1F20 R  R, R, R R7969 Avg Prover Temperature Last ‐ 3 Run Float 1F21 R  R, R, R R7970 Avg Prover Pressure Last ‐ 3 Run Float 1F22 R  R, R, R R7971 Avg API60/Sg@60F/Density@15C Last ‐ 3 

RunFloat 1F23 R   R, R, R R

7972 Avg Flowrate Last ‐ 3 Run Float 1F24 R  R, R, R R7973 Avg Meter Temperature Last ‐ 2 Run Float 1F25 R  R, R, R R7974 Avg Meter Pressure Last ‐ 2 Run Float 1F26 R  R, R, R R7975 Avg Prover Temperature Last ‐ 2 Run Float 1F27 R  R, R, R R7976 Avg Prover Pressure Last ‐ 2 Run Float 1F28 R  R, R, R R7977 Avg API60/Sg@60F/Density@15C Last ‐ 2 

RunFloat 1F29 R   R, R, R R

7978 Avg Flowrate Last ‐ 2 Run Float 1F2A R  R, R, R R7979 Avg Meter Temperature Last ‐ 1 Run Float 1F2B R  R, R, R R7980 Avg Meter Pressure Last ‐ 1 Run Float 1F2C R  R, R, R R7981 Avg Prover Temperature Last ‐ 1 Run Float 1F2D R  R, R, R R7982 Avg Prover Pressure Last ‐ 1 Run Float 1F2E R  R, R, R R7983 Avg API60/Sg@60F/Density@15C Last ‐ 1 

RunFloat 1F2F R   R, R, R R

7984 Avg Flowrate Last ‐ 1 Run Float 1F30 R  R, R, R R7985 Avg Meter Temperature Last ‐ 0 Run Float 1F31 R  R, R, R R7986 Avg Meter Pressure Last ‐ 0 Run Float 1F32 R  R, R, R R7987 Avg Prover Temperature Last ‐ 0 Run Float 1F33 R  R, R, R R7988 Avg Prover Pressure Last ‐ 0 Run Float 1F34 R  R, R, R R

Page125 of 229 1/25/2013

Page 126: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

7989 Avg API60/Sg@60F/Density@15C Last ‐ 0 Run

Float 1F35 R   R, R, R R

7990 Avg Flowrate Last ‐ 0 Run Float 1F36 R  R, R, R R7991 Avg Meter Temperature 1st Run Float 1F37 R  R, R, R R7992 Avg Meter Pressure 1st Run Float 1F38 R  R, R, R R7993 Avg Prover Temperature 1st Run Float 1F39 R  R, R, R R7994 Avg Prover Pressure 1st Run Float 1F3A R  R, R, R R7995 Avg API60/Sg@60F/Density@15C 1st Run Float 1F3B R   R, R, R R

7996 Avg Meter Flowrate 1st Run Float 1F3C R  R, R, R R7997 Avg Meter Temperature 2nd Run Float 1F3D R  R, R, R R7998 Avg Meter Pressure 2nd Run Float 1F3E R  R, R, R R7999 Avg Prover Temperature 2nd Run Float 1F3F R  R, R, R R8000 Avg Prover Pressure 2nd Run Float 1F40 R  R, R, R R8001 Avg API60/Sg@60F/Density@15C 2nd 

RunFloat 1F41 R   R, R, R R

8002 Avg Meter Flowrate 2nd Run Float 1F42 R  R, R, R R8003 Avg Meter Temperature 3rd Run Float 1F43 R  R, R, R R8004 Avg Meter Pressure 3rd Run Float 1F44 R  R, R, R R8005 Avg Prover Temperature 3rd Run Float 1F45 R  R, R, R R8006 Avg Prover Pressure 3rd Run Float 1F46 R  R, R, R R8007 Avg API60/Sg@60F/Density@15C 3rd 

RunFloat 1F47 R   R, R, R R

8008 Avg Meter Flowrate 3rd Run Float 1F48 R  R, R, R R8009 Avg Meter Temperature 4th Run Float 1F49 R  R, R, R R8010 Avg Meter Pressure 4th Run Float 1F4A R  R, R, R R8011 Avg Prover Temperature 4th Run Float 1F4B R  R, R, R R8012 Avg Prover Pressure 4th Run Float 1F4C R  R, R, R R8013 Avg API60/Sg@60F/Density@15C 4th Run Float 1F4D R   R, R, R R

8014 Avg Meter Flowrate 4th Run Float 1F4E R  R, R, R R8015 Avg Meter Temperature 5th Run Float 1F4F R  R, R, R R8016 Avg Meter Pressure 5th Run Float 1F50 R  R, R, R R8017 Avg Prover Temperature 5th Run Float 1F51 R  R, R, R R8018 Avg Prover Pressure 5th Run Float 1F52 R  R, R, R R8019 Avg API60/Sg@60F/Density@15C 5th Run Float 1F53 R   R, R, R R

Page126 of 229 1/25/2013

Page 127: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8020 Avg Meter Flowrate 5th Run Float 1F54 R  R, R, R R8021 Avg Meter Temperature 6th Run Float 1F55 R  R, R, R R8022 Avg Meter Pressure 6th Run Float 1F56 R  R, R, R R8023 Avg Prover Temperature 6th Run Float 1F57 R  R, R, R R8024 Avg Prover Pressure 6th Run Float 1F58 R  R, R, R R8025 Avg API60/Sg@60F/Density@15C 6th Run Float 1F59 R   R, R, R R

8026 Avg Meter Flowrate 6th Run Float 1F5A R  R, R, R R8027 Avg Meter Temperature 7th Run Float 1F5B R  R, R, R R8028 Avg Meter Pressure 7th Run Float 1F5C R  R, R, R R8029 Avg Prover Temperature 7th Run Float 1F5D R  R, R, R R8030 Avg Prover Pressure 7th Run Float 1F5E R  R, R, R R8031 Avg API60/Sg@60F/Density@15C 7th Run Float 1F5F R   R, R, R R

8032 Avg Meter Flowrate 7th Run Float 1F60 R  R, R, R R8033 Avg Meter Temperature 8th Run Float 1F61 R  R, R, R R8034 Avg Meter Pressure 8th Run Float 1F62 R  R, R, R R8035 Avg Prover Temperature 8th Run Float 1F63 R  R, R, R R8036 Avg Prover Pressure 8th Run Float 1F64 R  R, R, R R8037 Avg API60/Sg@60F/Density@15C 8th Run Float 1F65 R   R, R, R R

8038 Avg Meter Flowrate 8th Run Float 1F66 R  R, R, R R8039 Avg Meter Temperature 9th Run Float 1F67 R  R, R, R R8040 Avg Meter Pressure 9th Run Float 1F68 R  R, R, R R8041 Avg Prover Temperature 9th Run Float 1F69 R  R, R, R R8042 Avg Prover Pressure 9th Run Float 1F6A R  R, R, R R8043 Avg API60/Sg@60F/Density@15C 9th Run Float 1F6B R   R, R, R R

8044 Avg Meter Flowrate 9th Run Float 1F6C R  R, R, R R8045 Avg Meter Temperature 10th Run Float 1F6D R  R, R, R R8046 Avg Meter Pressure 10th Run Float 1F6E R  R, R, R R8047 Avg Prover Temperature 10th Run Float 1F6F R  R, R, R R8048 Avg Prover Pressure 10th Run Float 1F70 R  R, R, R R8049 Avg API60/Sg@60F/Density@15C 10th 

RunFloat 1F71 R   R, R, R R

8050 Avg Meter Flowrate 10th Run Float 1F72 R  R, R, R R8051 Average Counts of Runs Float 1F73 R  R, R, R R8052 Average Meter Temperature of Runs Float 1F74 R  R, R, R R

Page127 of 229 1/25/2013

Page 128: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8053 Average Meter Pressure of Runs Float 1F75 R  R, R, R R8054 Average Prover Temperature of Runs Float 1F76 R  R, R, R R8055 Average Prover Pressure of Runs Float 1F77 R  R, R, R R8056 Average API60/SG60/[email protected] of 

RunsFloat 1F78 R   R, R, R R

8057 Average Proving Meter Flowrate of Runs Float 1F79 R  R, R, R R8058 Counts/Meter Factor % Deviation 

Between RunsFloat 1F7A R   R, R, R R

8059 Ctsp Float 1F7B R  R, ‐, R R8060 Cpsp Float 1F7C R  R, ‐, R R8061 Ctlp Float 1F7D R  R, ‐, R R8062 Cplp Float 1F7E R  R, ‐, R R8063 CCFp(Combined Correct Factor of Prover) Float 1F7F R   R, ‐, R R

8064 Corrected Prover Volume Float 1F80 R  R, ‐, R R8065 Proving Meter Volume Float 1F81 R  R, ‐, R R8066 Ctlm Float 1F82 R  R, ‐, R R8067 Cplm Float 1F83 R  R, ‐, R R8068 CCFm(Combined Correct Factor of 

Proving Meter)Float 1F84 R   R, ‐, R R

8069 Corrected Meter Volume Float 1F85 R  R, ‐, R R8070 Average Counts * LCF Float 1F86 R  R, ‐, R R8071 MF Deviation % From Previous MF Float 1F87 R  R, R, R R8072 Actual K Factor Float 1F88 R  R, ‐, R R8073 Average Proving Meter Flow Hertz Float 1F89 R  R, ‐, R R8074 Prover Compressibility F Factor Float 1F8A R  R, ‐, R R8075 Proving Meter Compressibility F Factor Float 1F8B R  R, ‐, R R8076 Average Meter Density of Runs Float 1F8C R  R, ‐, R R8077 Average Sg@60F/Density@15C Float 1F8D R  R, ‐, R R8078 Average LCF Float 1F8E R  R, ‐, R R8079 Average Viscosity of Runs Float 1F8F R  R, ‐, R R8080 Master Meter Volume 1st Run Float 1F90 R  R, R, R R8081 Master Meter MF 1st Run Float 1F91 R  R, R, R R8082 Master Meter CTL 1st Run Float 1F92 R  R, R, R R

Page128 of 229 1/25/2013

Page 129: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8083 Master Meter CPL 1st Run Float 1F93 R  R, R, R R8084 Master Meter CCF 1st Run Float 1F94 R  R, R, R R8085 Master Meter Corrected Volume 1st Run Float 1F95 R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 1st Run

R   R,  R,  R R

8086 Proving Meter Volume 1st Run Float 1F96 R  R, R, R R8087 Proving Meter CTL 1st Run Float 1F97 R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 1st Run

R   R,  R,  R R

8088 Proving Meter CPL 1st Run Float 1F98 R  R, R, R R8089 Proving Meter CCF 1st Run Float 1F99 R  R, R, R R8090 Proving Meter Corrected Volume 1st Run Float 1F9A R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 1st Run

R   R,  R,  R R

8091 Master Meter Proving MF 1st Run Float 1F9B R  R, R, R R8092 Master Meter Volume 2nd Run Float 1F9C R  R, R, R R8093 Master Meter MF 2nd Run Float 1F9D R  R, R, R R8094 Master Meter CTL 2nd Run Float 1F9E R  R, R, R R8095 Master Meter CPL 2nd Run Float 1F9F R  R, R, R R8096 Master Meter CCF 2nd Run Float 1FA0 R  R, R, R R8097 Master Meter Corrected Volume 2nd Run Float 1FA1 R   R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 2nd Run

R   R,  R,  R R

8098 Proving Meter Volume 2nd Run Float 1FA2 R  R, R, R R8099 Proving Meter CTL 2nd Run Float 1FA3 R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 2nd Run

R   R,  R,  R R

8100 Proving Meter CPL 2nd Run Float 1FA4 R  R, R, R R8101 Proving Meter CCF 2nd Run Float 1FA5 R  R, R, R R8102 Proving Meter Corrected Volume 2nd 

RunFloat 1FA6 R   R, R, R R

Page129 of 229 1/25/2013

Page 130: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 2nd Run

R   R,  R,  R R

8103 Master Meter Proving MF 2nd Run Float 1FA7 R  R, R, R R8104 Master Meter Volume 3rd Run Float 1FA8 R  R, R, R R8105 Master Meter MF 3rd Run Float 1FA9 R  R, R, R R8106 Master Meter CTL 3rd Run Float 1FAA R  R, R, R R8107 Master Meter CPL 3rd Run Float 1FAB R  R, R, R R8108 Master Meter CCF 3rd Run Float 1FAC R  R, R, R R8109 Master Meter Corrected Volume 3rd Run Float 1FAD R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 3rd Run

R   R,  R,  R R

8110 Proving Meter Volume 3rd Run Float 1FAE R  R, R, R R8111 Proving Meter CTL 3rd Run Float 1FAF R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 3rd Run

R   R,  R,  R R

8112 Proving Meter CPL 3rd Run Float 1FB0 R  R, R, R R8113 Proving Meter CCF 3rd Run Float 1FB1 R  R, R, R R8114 Proving Meter Corrected Volume 3rd Run Float 1FB2 R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 3rd Run

R   R,  R,  R R

8115 Master Meter Proving MF 3rd Run Float 1FB3 R  R, R, R R8116 Master Meter Volume 4th Run Float 1FB4 R  R, R, R R8117 Master Meter MF 4th Run Float 1FB5 R  R, R, R R8118 Master Meter CTL 4th Run Float 1FB6 R  R, R, R R8119 Master Meter CPL 4th Run Float 1FB7 R  R, R, R R8120 Master Meter CCF 4th Run Float 1FB8 R  R, R, R R8121 Master Meter Corrected Volume 4th Run Float 1FB9 R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 4th Run

R   R,  R,  R R

8122 Proving Meter Volume 4th Run Float 1FBA R  R, R, R R8123 Proving Meter CTL 4th Run Float 1FBB R  R, R, R R

Page130 of 229 1/25/2013

Page 131: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Pipe/Small Volume Prover Average Proving Meter SG60 4th Run

R   R,  R,  R R

8124 Proving Meter CPL 4th Run Float 1FBC R  R, R, R R8125 Proving Meter CCF 4th Run Float 1FBD R  R, R, R R8126 Proving Meter Corrected Volume 4th Run Float 1FBE R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 4th Run

R   R,  R,  R R

8127 Master Meter Proving MF 4th Run Float 1FBF R  R, R, R R8128 Master Meter Volume 5th Run Float 1FC0 R  R, R, R R8129 Master Meter MF 5th Run Float 1FC1 R  R, R, R R8130 Master Meter CTL 5th Run Float 1FC2 R  R, R, R R8131 Master Meter CPL 5th Run Float 1FC3 R  R, R, R R8132 Master Meter CCF 5th Run Float 1FC4 R  R, R, R R8133 Master Meter Corrected Volume 5th Run Float 1FC5 R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 5th Run

R   R,  R,  R R

8134 Proving Meter Volume 5th Run Float 1FC6 R  R, R, R R8135 Proving Meter CTL 5th Run Float 1FC7 R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 5th Run

R   R,  R,  R R

8136 Proving Meter CPL 5th Run Float 1FC8 R  R, R, R R8137 Proving Meter CCF 5th Run Float 1FC9 R  R, R, R R8138 Proving Meter Corrected Volume 5th Run Float 1FCA R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 5th Run

R   R,  R,  R R

8139 Master Meter Proving MF 5th Run Float 1FCB R  R, R, R R8140 Master Meter Volume 6th Run Float 1FCC R  R, R, R R8141 Master Meter MF 6th Run Float 1FCD R  R, R, R R8142 Master Meter CTL 6th Run Float 1FCE R  R, R, R R8143 Master Meter CPL 6th Run Float 1FCF R  R, R, R R8144 Master Meter CCF 6th Run Float 1FD0 R  R, R, R R

Page131 of 229 1/25/2013

Page 132: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8145 Master Meter Corrected Volume 6th Run Float 1FD1 R  R, R, R RMaster Meter Mass Pulses Proving ‐ Master Meter Total Pulses 6th Run

R   R,  R,  R R

8146 Proving Meter Volume 6th Run Float 1FD2 R  R, R, R R8147 Proving Meter CTL 6th Run Float 1FD3 R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 6th Run

R   R,  R,  R R

8148 Proving Meter CPL 6th Run Float 1FD4 R  R, R, R R8149 Proving Meter CCF 6th Run Float 1FD5 R  R, R, R R8150 Proving Meter Corrected Volume 6th Run Float 1FD6 R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 6th Run

R   R,  R,  R R

8151 Master Meter Proving MF 6th Run Float 1FD7 R  R, R, R R8152 Master Meter Volume 7th Run Float 1FD8 R  R, R, R R8153 Master Meter MF 7th Run Float 1FD9 R  R, R, R R8154 Master Meter CTL 7th Run Float 1FDA R  R, R, R R8155 Master Meter CPL 7th Run Float 1FDB R  R, R, R R8156 Master Meter CCF 7th Run Float 1FDC R  R, R, R R8157 Master Meter Corrected Volume 7th Run Float 1FDD R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 7th Run

R   R,  R,  R R

8158 Proving Meter Volume 7th Run Float 1FDE R  R, R, R R8159 Proving Meter CTL 7th Run Float 1FDF R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 7th Run

R   R,  R,  R R

8160 Proving Meter CPL 7th Run Float 1FE0 R  R, R, R R8161 Proving Meter CCF 7th Run Float 1FE1 R  R, R, R R8162 Proving Meter Corrected Volume 7th Run Float 1FE2 R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 7th Run

R   R,  R,  R R

Page132 of 229 1/25/2013

Page 133: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8163 Master Meter Proving MF 7th Run Float 1FE3 R  R, R, R R8164 Master Meter Volume 8th Run Float 1FE4 R  R, R, R R8165 Master Meter MF 8th Run Float 1FE5 R  R, R, R R8166 Master Meter CTL 8th Run Float 1FE6 R  R, R, R R8167 Master Meter CPL 8th Run Float 1FE7 R  R, R, R R8168 Master Meter CCF 8th Run Float 1FE8 R  R, R, R R8169 Master Meter Corrected Volume 8th Run Float 1FE9 R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 8th Run

R   R,  R,  R R

8170 Proving Meter Volume 8th Run Float 1FEA R  R, R, R R8171 Proving Meter CTL 8th Run Float 1FEB R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG 8th Run

R   R,  R,  R R

8172 Proving Meter CPL 8th Run Float 1FEC R  R, R, R R8173 Proving Meter CCF 8th Run Float 1FED R  R, R, R R8174 Proving Meter Corrected Volume 8th Run Float 1FEE R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 8th Run

R   R,  R,  R R

8175 Master Meter Proving MF 8th Run Float 1FEF R  R, R, R R8176 Master Meter Volume 9th Run Float 1FF0 R  R, R, R R8177 Master Meter MF 9th Run Float 1FF1 R  R, R, R R8178 Master Meter CTL 9th Run Float 1FF2 R  R, R, R R8179 Master Meter CPL 9th Run Float 1FF3 R  R, R, R R8180 Master Meter CCF 9th Run Float 1FF4 R  R, R, R R8181 Master Meter Corrected Volume 9th Run Float 1FF5 R  R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 9th Run

R   R,  R,  R R

8182 Proving Meter Volume 9th Run Float 1FF6 R  R, R, R R8183 Proving Meter CTL 9th Run Float 1FF7 R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 9th Run

R   R,  R,  R R

8184 Proving Meter CPL 9th Run Float 1FF8 R  R, R, R RPage133 of 229 1/25/2013

Page 134: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8185 Proving Meter CCF 9th Run Float 1FF9 R  R, R, R R8186 Proving Meter Corrected Volume 9th Run Float 1FFA R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 9th Run

R   R,  R,  R R

8187 Master Meter Proving MF 9th Run Float 1FFB R  R, R, R R8188 Master Meter Volume 10th Run Float 1FFC R  R, R, R R8189 Master Meter MF 10th Run Float 1FFD R  R, R, R R8190 Master Meter CTL 10th Run Float 1FFE R  R, R, R R8191 Master Meter CPL 10th Run Float 1FFF R  R, R, R R8192 Master Meter CCF 10th Run Float 2000 R  R, R, R R8193 Master Meter Corrected Volume 10th 

RunFloat 2001 R   R, R, R R

Master Meter Mass Pulses Proving ‐ Master Meter Total Pulses 10th Run

R   R,  R,  R R

8194 Proving Meter Volume 10th Run Float 2002 R  R, R, R R8195 Proving Meter CTL 10th Run Float 2003 R  R, R, R R

Pipe/Small Volume Prover Average Proving Meter SG60 10th Run

R   R,  R,  R R

8196 Proving Meter CPL 10th Run Float 2004 R  R, R, R R8197 Proving Meter CCF 10th Run Float 2005 R  R, R, R R8198 Proving Meter Corrected Volume 10th 

RunFloat 2006 R   R, R, R R

Master Meter Mass Pulses Proving ‐ Test Meter Total Pulses 10th Run

R   R,  R,  R R

8199 Master Meter Proving MF 10th Run Float 2007 R  R, R, R R8200 Series 1 Average Counts Float 2008 R  R, ‐, R R8201 Series 1 Average Meter Temperature Float 2009 R  R, ‐, R R8202 Series 1 Average Meter Pressure Float 200A R  R, ‐, R R8203 Series 1 Average Prover Temperature Float 200B R  R, ‐, R R8204 Series 1 Average Prover Pressure Float 200C R  R, ‐, R R8205 Series 1 Average Gravity @ 60F/Ref.T Float 200D R  R, ‐, R R8206 Series 1 Average Flowrate Float 200E R  R, ‐, R R

Page134 of 229 1/25/2013

Page 135: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8207 Series 1 Ctsp Float 200F R  R, ‐, R R8208 Series 1 Cpsp Float 2010 R  R, ‐, R R8209 Series 1 Ctlp Float 2011 R  R, ‐, R R8210 Series 1 Cplp Float 2012 R  R, ‐, R R8211 Series 1 Net Prover Volume Float 2013 R  R, ‐, R R8212 Series 1 Ctlm Float 2014 R  R, ‐, R R8213 Series 1 Cplm Float 2015 R  R, ‐, R R8214 Series 1 Meter Gross Volume Float 2016 R  R, ‐, R R8215 Series 1 Meter Net Volume Float 2017 R  R, ‐, R R8216 Series 1 Prover Volume @ Pv Pressure Float 2018 R  R, ‐, R R8217 Series 2 Prover Volume @ Pv Pressure Float 2019 R  R, ‐, R R8218 Series 1 Meter Factor Float 201A R  R, ‐, R R8219 Series 2 Meter Factor Float 201B R  R, ‐, R R8220 Proving Meter Observed Gravity Float 201C R  R, ‐, R R8221 Proving Meter Density Temperature Float 201D R  R, ‐, R R8222 Proving Meter API60/API@15C Float 201E R  R, ‐, R R8223 Proving Meter SG60/Density@15C Float 201F R  R, ‐, R R8224 Proving Meter Temperature Float 2020 R  R, ‐, R R8225 Proving Meter Pressure Float 2021 R  R, ‐, R R8226 Proving Meter Flowrate Float 2022 R  R, ‐, R R8227 Proving Meter Density Float 2023 R  R, ‐, R R8228 Proving Meter SG @ 60 Deg.F/Density @ 

15CFloat 2024 R   R, ‐, R R

8229 Proving Meter API @ 60 Deg.F Float 2025 R  R, ‐, R R8230 Proving Meter Gross Flowrate Float 2026 R  R, ‐, R R8231 Mass Pulses Proving Prover Temperature 

1st RunFloat 2027 R   R, R, R R

8232 Mass Pulses Proving Prover Pressure 1st Run

Float 2028 R   R, R, R R

8233 Mass Pulses Proving Prover Density 1st Run

Float 2029 R   R, R, R R

Linear Prover Viscosity 1st Run R  R, R, R R

Page135 of 229 1/25/2013

Page 136: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8234 Mass Pulses Proving Meter Temperature 1st Run

Float 202A R   R, R, R R

8235 Mass Pulses Proving Meter Pressure 1st Run

Float 202B R   R, R, R R

8236 Mass Pulses Proving Meter Density 1st Run

Float 202C R   R, R, R R

8237 Mass Pulses Proving Meter Density @ Ref T 1st Run

Float 202D R   R, R, R R

8238 Mass Pulses Proving Ctlp 1st Run Float 202E R  R, R, R R8239 Mass Pulses Proving Cplp 1st Run Float 202F R  R, R, R R8240 Mass Pulses Proving Ctlm 1st Run Float 2030 R  R, R, R R8241 Mass Pulses Proving Cplm 1st Run Float 2031 R  R, R, R R8242 Mass Pulses Proving Ctsp 1st Run Float 2032 R  R, R, R R

Linear Proving LCF 1st Run R  R, R, R R8243 Mass Pulses Proving Cpsp 1st Run Float 2033 R  R, R, R R8244 Mass Pulses Proving Prover Volume 1st 

RunFloat 2034 R   R, R, R R

8245 Mass Pulses Proving Prover Mass 1st Run Float 2035 R   R, R, R R

8246 Mass Pulses Proving Meter Mass 1st Run Float 2036 R   R, R, R R

8247 Mass Pulses Proving Meter Factor 1st Run Float 2037 R   R, R, R R

8248 Mass Pulses Proving Prover Temperature 2nd Run

Float 2038 R   R, R, R R

8249 Mass Pulses Proving Prover Pressure 2nd Run

Float 2039 R   R, R, R R

Page136 of 229 1/25/2013

Page 137: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8250 Mass Pulses Proving Prover Density 2nd Run

Float 203A R   R, R, R R

Linear Proving Viscosity 2nd Run R  R, R, R R8251 Mass Pulses Proving Meter Temperature 

2nd RunFloat 203B R   R, R, R R

8252 Mass Pulses Proving Meter Pressure 2nd Run

Float 203C R   R, R, R R

8253 Mass Pulses Proving Meter Density 2nd Run

Float 203D R   R, R, R R

8254 Mass Pulses Proving Meter Density @Ref T 2nd Run

Float 203E R   R, R, R R

8255 Mass Pulses Proving Ctlp 2nd Run Float 203F R  R, R, R R8256 Mass Pulses Proving Cplp 2nd Run Float 2040 R  R, R, R R8257 Mass Pulses Proving Ctlm 2nd Run Float 2041 R  R, R, R R8258 Mass Pulses Proving Cplm 2nd Run Float 2042 R  R, R, R R8259 Mass Pulses Proving Ctsp 2nd Run Float 2043 R  R, R, R R

Linear Proving LCF 2nd Run R  R, R, R R8260 Mass Pulses Proving Cpsp 2nd Run Float 2044 R  R, R, R R8261 Mass Pulses Proving Prover Volume 2nd 

RunFloat 2045 R   R, R, R R

8262 Mass Pulses Proving Prover Mass 2nd Run Float 2046 R   R, R, R R

8263 Mass Pulses Proving Meter Mass 2nd Run Float 2047 R   R, R, R R

8264 Mass Pulses Proving Meter Factor 2nd Run

Float 2048 R   R, R, R R

8265 Mass Pulses Proving Prover Temperature 3rd Run

Float 2049 R   R, R, R R

Page137 of 229 1/25/2013

Page 138: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8266 Mass Pulses Proving Prover Pressure 3rd Run

Float 204A R   R, R, R R

8267 Mass Pulses Proving Prover Density 3rd Run

Float 204B R   R, R, R R

Linear Proving Viscosity 3rd Run R  R, R, R R8268 Mass Pulses Proving Meter Temperature 

3rd RunFloat 204C R   R, R, R R

8269 Mass Pulses Proving Meter Pressure 3rd Run

Float 204D R   R, R, R R

8270 Mass Pulses Proving Meter Density 3rd Run

Float 204E R   R, R, R R

8271 Mass Pulses Proving Meter Density @Ref T 3rd Run

Float 204F R   R, R, R R

8272 Mass Pulses Proving Ctlp 3rd Run Float 2050 R  R, R, R R8273 Mass Pulses Proving Cplp 3rd Run Float 2051 R  R, R, R R8374 Mass Pulses Proving Ctlm 3rd Run Float 20B6 R  R, R, R R8275 Mass Pulses Proving Cplm 3rd Run Float 2053 R  R, R, R R8276 Mass Pulses Proving Ctsp 3rd Run Float 2054 R  R, R, R R

Linear Proving LCF 3rd Run R  R, R, R R8277 Mass Pulses Proving Cpsp 3rd Run Float 2055 R  R, R, R R8278 Mass Pulses Proving Prover Volume 3rd 

RunFloat 2056 R   R, R, R R

8279 Mass Pulses Proving Prover Mass 3rd Run Float 2057 R   R, R, R R

8280 Mass Pulses Proving Meter Mass 3rd Run Float 2058 R   R, R, R R

8281 Mass Pulses Proving Meter Factor 3rd Run

Float 2059 R   R, R, R R

Page138 of 229 1/25/2013

Page 139: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8282 Mass Pulses Proving Prover Temperature 4th Run

Float 205A R   R, R, R R

8283 Mass Pulses Proving Prover Pressure 4th Run

Float 205B R   R, R, R R

8284 Mass Pulses Proving Prover Density 4th Run

Float 205C R   R, R, R R

Linear Proving Viscosity 4th Run R  R, R, R R8285 Mass Pulses Proving Meter Temperature 

4th RunFloat 205D R   R, R, R R

8286 Mass Pulses Proving Meter Pressure 4th Run

Float 205E R   R, R, R R

8287 Mass Pulses Proving Meter Density 4th Run

Float 205F R   R, R, R R

8288 Mass Pulses Proving Meter Density @Ref T 4th Run

Float 2060 R   R, R, R R

8289 Mass Pulses Proving Ctlp 4th Run Float 2061 R  R, R, R R8290 Mass Pulses Proving Cplp 4th Run Float 2062 R  R, R, R R8291 Mass Pulses Proving Ctlm 4th Run Float 2063 R  R, R, R R8292 Mass Pulses Proving Cplm 4th Run Float 2064 R  R, R, R R8293 Mass Pulses Proving Ctsp 4th Run Float 2065 R  R, R, R R

Linear Proving LCF 4th Run R  R, R, R R8294 Mass Pulses Proving Cpsp 4th Run Float 2066 R  R, R, R R8295 Mass Pulses Proving Prover Volume 4th 

RunFloat 2067 R   R, R, R R

8296 Mass Pulses Proving Prover Mass 4th Run Float 2068 R   R, R, R R

8297 Mass Pulses Proving Meter Mass 4th Run Float 2069 R   R, R, R R

Page139 of 229 1/25/2013

Page 140: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8298 Mass Pulses Proving Meter Factor 4th Run

Float 206A R   R, R, R R

8299 Mass Pulses Proving Prover Temperature 5th Run

Float 206B R   R, R, R R

8300 Mass Pulses Proving Prover Pressure 5th Run

Float 206C R   R, R, R R

8301 Mass Pulses Proving Prover Density 5th Run

Float 206D R   R, R, R R

Linear Proving Viscosity 5th Run R  R, R, R R8302 Mass Pulses Proving Meter Temperature 

5th RunFloat 206E R   R, R, R R

8303 Mass Pulses Proving Meter Pressure 5th Run

Float 206F R   R, R, R R

8304 Mass Pulses Proving Meter Density 5th Run

Float 2070 R   R, R, R R

8305 Mass Pulses Proving Meter Density @Ref T 5th Run

Float 2071 R   R, R, R R

8306 Mass Pulses Proving Ctlp 5th Run Float 2072 R  R, R, R R8307 Mass Pulses Proving Cplp 5th Run Float 2073 R  R, R, R R8308 Mass Pulses Proving Ctlm 5th Run Float 2074 R  R, R, R R8309 Mass Pulses Proving Cplm 5th Run Float 2075 R  R, R, R R8310 Mass Pulses Proving Ctsp 5th Run Float 2076 R  R, R, R R

Linear Proving LCF 5th Run R  R, R, R R8311 Mass Pulses Proving Cpsp 5th Run Float 2077 R  R, R, R R8312 Mass Pulses Proving Prover Volume 5th 

RunFloat 2078 R   R, R, R R

8313 Mass Pulses Proving Prover Mass 5th Run Float 2079 R   R, R, R R

Page140 of 229 1/25/2013

Page 141: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8314 Mass Pulses Proving Meter Mass 5th Run Float 207A R   R, R, R R

8315 Mass Pulses Proving Meter Factor 5th Run

Float 207B R   R, R, R R

8316 Mass Pulses Proving Prover Temperature 6th Run

Float 207C R   R, R, R R

8317 Mass Pulses Proving Prover Pressure 6th Run

Float 207D R   R, R, R R

8318 Mass Pulses Proving Prover Density 6th Run

Float 207E R   R, R, R R

Linear Proving Viscosity 6th Run R  R, R, R R8319 Mass Pulses Proving Meter Temperature 

6th RunFloat 207F R   R, R, R R

8320 Mass Pulses Proving Meter Pressure 6th Run

Float 2080 R   R, R, R R

8321 Mass Pulses Proving Meter Density 6th Run

Float 2081 R   R, R, R R

8322 Mass Pulses Proving Meter Density @Ref T 6th Run

Float 2082 R   R, R, R R

8323 Mass Pulses Proving Ctlp 6th Run Float 2083 R  R, R, R R8324 Mass Pulses Proving Cplp 6th Run Float 2084 R  R, R, R R8325 Mass Pulses Proving Ctlm 6th Run Float 2085 R  R, R, R R8326 Mass Pulses Proving Cplm 6th Run Float 2086 R  R, R, R R8327 Mass Pulses Proving Ctsp 6th Run Float 2087 R  R, R, R R

Linear Proving LCF 6th Run R  R, R, R R8328 Mass Pulses Proving Cpsp 6th Run Float 2088 R  R, R, R R8329 Mass Pulses Proving Prover Volume 6th 

RunFloat 2089 R   R, R, R R

Page141 of 229 1/25/2013

Page 142: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8330 Mass Pulses Proving Prover Mass 6th Run Float 208A R   R, R, R R

8331 Mass Pulses Proving Meter Mass 6th Run Float 208B R   R, R, R R

8332 Mass Pulses Proving Meter Factor 6th Run

Float 208C R   R, R, R R

8333 Mass Pulses Proving Prover Temperature 7th Run

Float 208D R   R, R, R R

8334 Mass Pulses Proving Prover Pressure 7th Run

Float 208E R   R, R, R R

8335 Mass Pulses Proving Prover Density 7th Run

Float 208F R   R, R, R R

Linear Proving Viscosity 7th Run R  R, R, R R8336 Mass Pulses Proving Meter Temperature 

7th RunFloat 2090 R   R, R, R R

8337 Mass Pulses Proving Meter Pressure 7th Run

Float 2091 R   R, R, R R

8338 Mass Pulses Proving Meter Density 7th Run

Float 2092 R   R, R, R R

8339 Mass Pulses Proving Meter Density @Ref T 7th Run

Float 2093 R   R, R, R R

8340 Mass Pulses Proving Ctlp 7th Run Float 2094 R  R, R, R R8341 Mass Pulses Proving Cplp 7th Run Float 2095 R  R, R, R R8342 Mass Pulses Proving Ctlm 7th Run Float 2096 R  R, R, R R8343 Mass Pulses Proving Cplm 7th Run Float 2097 R  R, R, R R8344 Mass Pulses Proving Ctsp 7th Run Float 2098 R  R, R, R R

Linear Proving LCF 7th Run R  R, R, R8345 Mass Pulses Proving Cpsp 7th Run Float 2099 R  R, R, R R

Page142 of 229 1/25/2013

Page 143: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8346 Mass Pulses Proving Prover Volume 7th Run

Float 209A R   R, R, R R

8347 Mass Pulses Proving Prover Mass 7th Run Float 209B R   R, R, R R

8348 Mass Pulses Proving Meter Mass 7th Run Float 209C R   R, R, R R

8349 Mass Pulses Proving Meter Factor 7th Run

Float 209D R   R, R, R R

8350 Mass Pulses Proving Prover Temperature 8th Run

Float 209E R   R, R, R R

8351 Mass Pulses Proving Prover Pressure 8th Run

Float 209F R   R, R, R R

8352 Mass Pulses Proving Prover Density 8th Run

Float 20A0 R   R, R, R R

Linear Proving Viscosity 8th Run R  R, R, R R8353 Mass Pulses Proving Meter Temperature 

8th RunFloat 20A1 R   R, R, R R

8354 Mass Pulses Proving Meter Pressure 8th Run

Float 20A2 R   R, R, R R

8355 Mass Pulses Proving Meter Density 8th Run

Float 20A3 R   R, R, R R

8356 Mass Pulses Proving Meter Density @Ref T 8th Run

Float 20A4 R   R, R, R R

8357 Mass Pulses Proving Ctlp 8th Run Float 20A5 R  R, R, R R8358 Mass Pulses Proving Cplp 8th Run Float 20A6 R  R, R, R R8359 Mass Pulses Proving Ctlm 8th Run Float 20A7 R  R, R, R R8360 Mass Pulses Proving Cplm 8th Run Float 20A8 R  R, R, R R8361 Mass Pulses Proving Ctsp 8th Run Float 20A9 R  R, R, R R

Page143 of 229 1/25/2013

Page 144: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Linear Proving LCF 8th Run R  R, R, R R8362 Mass Pulses Proving Cpsp 8th Run Float 20AA R  R, R, R R8363 Mass Pulses Proving Prover Volume 8th 

RunFloat 20AB R   R, R, R R

8364 Mass Pulses Proving Prover Mass 8th Run Float 20AC R   R, R, R R

8365 Mass Pulses Proving Meter Mass 8th Run Float 20AD R   R, R, R R

8366 Mass Pulses Proving Meter Factor 8th Run

Float 20AE R   R, R, R R

8367 Mass Pulses Proving Prover Temperature 9th Run

Float 20AF R   R, R, R R

8368 Mass Pulses Proving Prover Pressure 9th Run

Float 20B0 R   R, R, R R

8369 Mass Pulses Proving Prover Density 9th Run

Float 20B1 R   R, R, R R

Linear Proving Viscosity 9th Run R  R, R, R R8370 Mass Pulses Proving Meter Temperature 

9th RunFloat 20B2 R   R, R, R R

8371 Mass Pulses Proving Meter Pressure 9th Run

Float 20B3 R   R, R, R R

8372 Mass Pulses Proving Meter Density 9th Run

Float 20B4 R   R, R, R R

8373 Mass Pulses Proving Meter Density @Ref T 9th Run

Float 20B5 R   R, R, R R

8374 Mass Pulses Proving Ctlp 9th Run Float 20B6 R  R, R, R R8375 Mass Pulses Proving Cplp 9th Run Float 20B7 R  R, R, R R8376 Mass Pulses Proving Ctlm 9th Run Float 20B8 R  R, R, R R

Page144 of 229 1/25/2013

Page 145: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8377 Mass Pulses Proving Cplm 9th Run Float 20B9 R  R, R, R R8378 Mass Pulses Proving Ctsp 9th Run Float 20BA R  R, R, R R

Linear Proving LCF 9th Run R  R, R, R R8379 Mass Pulses Proving Cpsp 9th Run Float 20BB R  R, R, R R8380 Mass Pulses Proving Prover Volume 9th 

RunFloat 20BC R   R, R, R R

8381 Mass Pulses Proving Prover Mass 9th Run Float 20BD R   R, R, R R

8382 Mass Pulses Proving Meter Mass 9th Run Float 20BE R   R, R, R R

8383 Mass Pulses Proving Meter Factor 9th Run

Float 20BF R   R, R, R R

8384 Mass Pulses Proving Prover Temperature 10th Run

Float 20C0 R   R, R, R R

8385 Mass Pulses Proving Prover Pressure 10th Run

Float 20C1 R   R, R, R R

8386 Mass Pulses Proving Prover Density 10th Run

Float 20C2 R   R, R, R R

Linear Proving Viscosity 10th Run R  R, R, R R8387 Mass Pulses Proving Meter Temperature 

10th RunFloat 20C3 R   R, R, R R

8388 Mass Pulses Proving Meter Pressure 10th Run

Float 20C4 R   R, R, R R

8389 Mass Pulses Proving Meter Density 10th Run

Float 20C5 R   R, R, R R

8390 Mass Pulses Proving Meter Density @Ref T 10th Run

Float 20C6 R   R, R, R R

8391 Mass Pulses Proving Ctlp 10th Run Float 20C7 R  R, R, R RPage145 of 229 1/25/2013

Page 146: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8392 Mass Pulses Proving Cplp 10th Run Float 20C8 R  R, R, R R8393 Mass Pulses Proving Ctlm 10th Run Float 20C9 R  R, R, R R8394 Mass Pulses Proving Cplm 10th Run Float 20CA R  R, R, R R8395 Mass Pulses Proving Ctsp 10th Run Float 20CB R  R, R, R R

Linear Proving LCF 10th Run R  R, R, R R8396 Mass Pulses Proving Cpsp 10th Run Float 20CC R  R, R, R R8397 Mass Pulses Proving Prover Volume 10th 

RunFloat 20CD R   R, R, R R

8398 Mass Pulses Proving Prover Mass 10th Run

Float 20CE R   R, R, R R

8399 Mass Pulses Proving Meter Mass 10th Run

Float 20CF R   R, R, R R

8400 Mass Pulses Proving Meter Factor 10th Run

Float 20D0 R   R, R, R R

8401 Linear Meter Volume Float 20D1 R  R, ‐, R R8402 Linear Corrected Meter Volume Float 20D2 R  R, ‐, R R8403 Average Prover Density of Runs Float 20D3 R  R, ‐, R R8404 Prover CTPL Float 20D4 R  R, ‐, R R8405 Proving Meter CTPL Float 20D5 R  R, ‐, R R8406 ‐ 8410 Reserved8411 Master Meter LCF 1st Run Float 20DB R  R, ‐, R R8412 Master Meter Viscosity 1st Run Float 20DC R  R, ‐, R R8413 Master Meter linear Volume 1st Run Float 20DD R  R, ‐, R R8414 Test Meter LCF 1st Run Float 20DE R  R, ‐, R R8415 Test Meter Viscosity 1st Run Float 20DF R  R, ‐, R R8416 Test Meter linear Volume 1st Run Float 20E0 R  R, ‐, R R8417 Linear Meter Factor 1st Run Float 20E1 R  R, ‐, R R8418 Master Meter LCF 2nd Run Float 20E2 R  R, ‐, R R8419 Master Meter Viscosity 2nd Run Float 20E3 R  R, ‐, R R8420 Master Meter linear Volume 2nd Run Float 20E4 R  R, ‐, R R8421 Test Meter LCF 2nd Run Float 20E5 R  R, ‐, R R8422 Test Meter Viscosity 2nd Run Float 20E6 R  R, ‐, R R8423 Test Meter linear Volume 2nd Run Float 20E7 R  R, ‐, R R8424 Linear Meter Factor 2nd Run Float 20E8 R  R, ‐, R R

Page146 of 229 1/25/2013

Page 147: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8425 Master Meter LCF 3rd Run Float 20E9 R  R, ‐, R R8426 Master Meter Viscosity 3rd Run Float 20EA R  R, ‐, R R8427 Master Meter Linear Volume 3rd Run Float 20EB R  R, ‐, R R8428 Test Meter LCF 3rd Run Float 20EC R  R, ‐, R R8429 Test Meter Viscosity 3rd Run Float 20ED R  R, ‐, R R8430 Test Meter Linear Volume 3rd Run Float 20EE R  R, ‐, R R8431 Linear Meter Factor 3rd Run Float 20EF R  R, ‐, R R8432 Master Meter LCF 4th Run Float 20F0 R  R, ‐, R R8433 Master Meter Viscosity 4th Run Float 20F1 R  R, ‐, R R8434 Master Meter Linear Volume 4th Run Float 20F2 R  R, ‐, R R8435 Test Meter LCF 4th Run Float 20F3 R  R, ‐, R R8436 Test Meter Viscosity 4th Run Float 20F4 R  R, ‐, R R8437 Test Meter Linear Volume 4th Run Float 20F5 R  R, ‐, R R8438 Linear Meter Factor 4th Run Float 20F6 R  R, ‐, R R8439 Master Meter LCF 5th Run Float 20F7 R  R, ‐, R R8440 Master Meter Viscosity 5th Run Float 20F8 R  R, ‐, R R8441 Master Meter Linear Volume 5th Run Float 20F9 R  R, ‐, R R8442 Test Meter LCF 5th Run Float 20FA R  R, ‐, R R8443 Test Meter Viscosity 5th Run Float 20FB R  R, ‐, R R8444 Test Meter Linear Volume 5th Run Float 20FC R  R, ‐, R R8445 Linear Meter Factor 5th Run Float 20FD R  R, ‐, R R8446 Master Meter LCF 6th Run Float 20FE R  R, ‐, R R8447 Master Meter Viscosity 6th Run Float 20FF R  R, ‐, R R8448 Master Meter Linear Volume 6th Run Float 2100 R  R, ‐, R R8449 Test Meter LCF 6th Run Float 2101 R  R, ‐, R R8450 Test Meter Viscosity 6th Run Float 2102 R  R, ‐, R R8451 Test Meter Linear Volume 6th Run Float 2103 R  R, ‐, R R8452 Linear Meter Factor 6th Run Float 2104 R  R, ‐, R R8453 Master Meter LCF 7th Run Float 2105 R  R, ‐, R R8454 Master Meter Viscosity 7th Run Float 2106 R  R, ‐, R R8455 Master Meter Linear Volume 7th Run Float 2107 R  R, ‐, R R8456 Test Meter LCF 7th Run Float 2108 R  R, ‐, R R8457 Test Meter Viscosity 7th Run Float 2109 R  R, ‐, R R8458 Test Meter Linear Volume 7th Run Float 210A R  R, ‐, R R8459 Linear Meter Factor 7th Run Float 210B R  R, ‐, R R8460 Master Meter LCF 8th Run Float 210C R  R, ‐, R R8461 Master Meter Viscosity 8th Run Float 210D R  R, ‐, R R8462 Master Meter Linear Volume 8th Run Float 210E R  R, ‐, R R

Page147 of 229 1/25/2013

Page 148: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8463 Test Meter LCF 8th Run Float 210F R  R, ‐, R R8464 Test Meter Viscosity 8th Run Float 2110 R  R, ‐, R R8465 Test Meter Linear Volume 8th Run Float 2111 R  R, ‐, R R8466 Linear Meter Factor 8th Run Float 2112 R  R, ‐, R R8467 Master Meter LCF 9th Run Float 2113 R  R, ‐, R R8468 Master Meter Viscosity 9th Run Float 2114 R  R, ‐, R R8469 Master Meter Linear Volume 9th Run Float 2115 R  R, ‐, R R8470 Test Meter LCF 9th Run Float 2116 R  R, ‐, R R8471 Test Meter Viscosity 9th Run Float 2117 R  R, ‐, R R8472 Test Meter Linear Volume 9th Run Float 2118 R  R, ‐, R R8473 Linear Meter Factor 9th Run Float 2119 R  R, ‐, R R8474 Master Meter LCF 10th Run Float 211A R  R, ‐, R R8475 Master Meter Viscosity 10th Run Float 211B R  R, ‐, R R8476 Master Meter Linear Volume 10th Run Float 211C R  R, ‐, R R8477 Test Meter LCF 10th Run Float 211D R  R, ‐, R R8478 Test Meter Viscosity 10th Run Float 211E R  R, ‐, R R8479 Test Meter Linear Volume 10th Run Float 211F R  R, ‐, R R8480 Linear Meter Factor 10th Run Float 2120 R  R, ‐, R R8481 Master Meter Proving /Mass Pulses 

Proving CTPLP 1st RunFloat 2121 R   R, ‐, R R

8482 Master Meter Proving /Mass Pulses Proving CTPLP 2nd Run

Float 2122 R   R, ‐, R R

8483 Master Meter Proving /Mass Pulses Proving CTPLP 3rd Run

Float 2123 R   R, ‐, R R

8484 Master Meter Proving /Mass Pulses Proving CTPLP 4th Run

Float 2124 R   R, ‐, R R

8485 Master Meter Proving /Mass Pulses Proving CTPLP 5th Run

Float 2125 R   R, ‐, R R

8486 Master Meter Proving /Mass Pulses Proving CTPLP 6th Run

Float 2126 R   R, ‐, R R

Page148 of 229 1/25/2013

Page 149: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8487 Master Meter Proving /Mass Pulses Proving CTPLP 7th Run

Float 2127 R   R, ‐, R R

8488 Master Meter Proving /Mass Pulses Proving CTPLP 8th Run

Float 2128 R   R, ‐, R R

8489 Master Meter Proving /Mass Pulses Proving CTPLP 9th Run

Float 2129 R   R, ‐, R R

8490 Master Meter Proving /Mass Pulses Proving CTPLP 10th Run

Float 212A R   R, ‐, R R

8491 ‐ 8499 Reserved

Floating Point Variables

8501 Meter 1 Previous Batch 'n' Avg Temperature

Float 2135 R   R, ‐, R R

8502 Meter 1 Previous Batch 'n' Avg Pressure Float 2136 R   R, ‐, R R

8503 Meter 1 Previous Batch 'n' Avg Density Float 2137 R gm/cc   R, ‐, R R

8504 Meter 1 Previous Batch 'n' Avg VCF Float 2138 R  R, ‐, R R8505 Meter 1 Previous Batch 'n' Avg CPL Float 2139 R  R, ‐, R R8506 Meter 1 Previous Batch 'n' Avg MF Float 213A R  R, ‐, R R8507 Meter 1 Previous Batch 'n' Avg SG Float 213B R  R, ‐, R R8508 Meter 1 Previous Batch 'n' Avg 

SG60/[email protected] 213C R/W  R/W, ‐, R Y R

8509 Meter 1 Previous Batch 'n' Avg DensityTemperature

Float 213D R   R, ‐, R R

8510 Meter 1 Previous Batch 'n' Avg Density Pressure

Float 213E R   R, ‐, R R

Page149 of 229 1/25/2013

Page 150: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8511 Meter 1 Prev Batch'n' Avg DensityCorrectionFactor

Float 213F R   R, ‐, R R

8512 Meter 1 Prev Batch'n' Avg Unfactored Density

Float 2140 R gm/cc   R, ‐, R R

8513 Meter 1 Prev Batch'n' Avg K Factor Float 2141 R  R, ‐, R R8514 Meter 1 Prev Batch'n' Avg Viscosity Float 2142 R  R, ‐, R R8515 Meter 1 Prev Batch'n' Avg LCF Float 2143 R  R, ‐, R R8516 Meter 1 Prev Batch'n' Avg G. Flowrate Float 2144 R  R, ‐, R R8517 Meter 1 Prev Batch'n' Avg %S&W Float 2145 R/W R/W, ‐, R Y R8518 Meter 1 Prev Batch'n' Avg Equilibrium 

PressureFloat 2146 R   R, ‐, R R

8519 Meter 1 Prev Batch'n' Avg API60 Float 2147 R/W R/W, ‐, R Y R8520 Meter 1 Previous Hour Avg Temperature. Float 2148 R  R, ‐, R R8521 Meter 1 Previous Hour Avg Pressure Float 2149 R  R, ‐, R R8522 Meter 1 Previous Hour Avg Density Float 214A R gm/cc   R, ‐, R R

8523 Meter 1 Previous Hour Avg SG @60 deg.F Float 214B R   R, ‐, R R

8524 Meter 1 Previous Hour Avg K Factor Float 214C R  R, ‐, R R8525 Meter 1 Previous Hour Avg MF Float 214D R  R, ‐, R R8526 Meter 1 Previous Hour Avg % S&W Float 214E R  R, ‐, R R8527 Meter 1 Previous Batch 'n' Avg CTPL Float 214F R  R, ‐, R R8528 Meter 1 Current Batch Avg CTPL Float 2150 R  R, ‐, R R8530 Meter 1 Previous Daily Avg API60 Float 2152 R  R, ‐, R R8531 Meter 1 Previous Daily Avg Temperature Float 2153 R  R, ‐, R R8532 Meter 1 Previous Daily Avg Pressure Float 2154 R  R, ‐, R R8533 Meter 1 Previous Daily Avg Density Float 2155 R gm/cc   R, ‐, R R

8534 Meter 1 Previous Daily Avg VCF Float 2156 R  R, ‐, R R8535 Meter 1 Previous Daily Avg CPL Float 2157 R  R, ‐, R R8536 Meter 1 Previous Daily Avg Meter Factor Float 2158 R   R, ‐, R R

8537 Meter 1 Previous Daily Avg SG Float 2159 R  R, ‐, R R

Page150 of 229 1/25/2013

Page 151: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8538 Meter 1 Previous Daily Avg SG60/[email protected]

Float 215A R   R, ‐, R R

8539 Meter 1 Previous Daily Avg Density Temperature

Float 215B R   R, ‐, R R

8540 Meter 1 Previous Daily Avg Density Pressure

Float 215C R   R, ‐, R R

8541 Meter 1 Previous Daily Avg DensityCorrectionFactor

Float 215D R   R, ‐, R R

8542 Meter 1 Previous Daily Avg Unfactored Density

Float 215E R gm/cc   R, ‐, R R

8543 Meter 1 Previous Daily Avg K Factor Float 215F R  R, ‐, R R8544 Meter 1 Previous Daily Avg Viscosity Float 2160 R  R, ‐, R R8545 Meter 1 Previous Daily Avg LCF Float 2161 R  R, ‐, R R8546 Meter 1 Previous Daily Avg G. Flowrate Float 2162 R  R, ‐, R R8547 Meter 1 Previous Daily Avg %S&W Float 2163 R  R, ‐, R R8548 Meter 1 Previous Daily Avg Equilibrium 

PressureFloat 2164 R   R, ‐, R R

8549 Meter 1 Previous Daily Gross in Float Format

Float 2165 R   R, ‐, R R

8550 Meter 1 Previous Daily Net in Float Format

Float 2166 R   R, ‐, R R

8551 Meter 1 Previous Daily Mass in Float Format

Float 2167 R   R, ‐, R R

8552 Meter 1 Previous Daily NSV in Float Format

Float 2168 R   R, ‐, R R

8553 Meter 1 Previous Daily Net @ 2nd Ref T in Float

Float 2169 R   R, ‐, R R

Page151 of 229 1/25/2013

Page 152: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8554 Meter 1 Previous Daily Avg CTPL Float 216A R  R, ‐, R R8555 Meter 1 Current Daily Avg CTPL Float 216B R  R, ‐, R R8556 Meter 1 Current Hour Avg 

Temperature(Transducer)Float 216C R   R, ‐, R R

8557 Meter 1 Current Hour Avg Pressure (Transducer)

Float 216D R   R, ‐, R R

8558 Meter 1 Current Hour Avg Gravity (Transducer)

Float 216E R   R, ‐, R R

8559 Meter 1 Current Hour Avg Density Tem(Transducer)

Float 216F R   R, ‐, R R

8560 Meter 1 Current Hour Avg Density Pressure(Trans)

Float 2170 R   R, ‐, R R

8561 Meter 1 Current Batch Avg DensityCorrectionFactor

Float 2171 R   R, ‐, R R

8562 Meter 1 Current Daily Avg DensityCorrectionFactor

Float 2172 R   R, ‐, R R

8563 Meter 1 Current Batch Avg Unfactored Density

Float 2173 R gm/cc   R, ‐, R R

8564 Meter 1 Current Daily Avg Unfactored Density

Float 2174 R   R, ‐, R R

8570 Meter 1 Current Hourly Avg Temperature Float 217A R  R, ‐, R R8571 Meter 1 Current Hourly Avg Pressure Float 217B R  R, ‐, R R8572 Meter 1 Current Hourly Avg Flowing 

DensityFloat 217C R gm/cc   R, ‐, R R

8573 Meter 1 Current Hourly Avg SG60/[email protected]

Float 217D R   R, ‐, R R

8574 Meter 1 Current Hourly Avg K Factor/DP Float 217E R  R, ‐, R RPage152 of 229 1/25/2013

Page 153: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8575 Meter 1 Current Hourly Avg MF or Density

Float 217F R Hourly average Meter Factor.   R, ‐, R R

8576 Meter 1 Current Hourly Avg %S&W Float 2180 R  R, ‐, R R8577 Meter 1 Current Batch Avg Viscosity Float 2181 R  R, ‐, R R8578 Meter 1 Current Batch Avg LCF Float 2182 R  R, ‐, R R8579 Meter 1 Current Batch Avg Gross 

FlowrateFloat 2183 R   R, ‐, R R

8580 Meter 1 Current Daily Avg Viscosity Float 2184 R  R, ‐, R R8581 Meter 1 Current Daily Avg LCF Float 2185 R  R, ‐, R R8582 Meter 1 Current Daily Avg Gross Flowrate Float 2186 R   R, ‐, R R

8583 Meter 1 Current Daily Avg %S&W Float 2187 R  R, ‐, R R8584 Meter 1 Current Batch Avg %S&W Float 2188 R  R, ‐, R R8585 Meter 1 Current Ctpl (API 11.1 2004) Float 2189 R  R, ‐, R R8586 Meter 1 Previous Batch Gross in Float 

FormatFloat 218A R   R, ‐, R R

8587 Meter 1 Previous Batch Net in Float Format

Float 218B R   R, ‐, R R

8588 Meter 1 Previous Batch Mass in Float Format

Float 218C R   R, ‐, R R

8589 Meter 1 Previous Batch Energy/NSV in Float Format

Float 218D R   R, ‐, R R

8590 Meter 1 Previous Batch Net @ 2nd Ref.T Float 218E R  R, ‐, R R8591 Meter 1 Calculated Sg60/Den15 if Table 

24C/54CFloat 218F R   R, ‐, R R

8592 Meter 1 Density Kg/m3 @60F &Ref P (API11.1 2004)

Float 2190 R   R, ‐, R R

Page153 of 229 1/25/2013

Page 154: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8593 Meter 1 Dens kg/m3 at AlternateT&P(API 11.1 2004)

Float 2191 R   R, ‐, R R

8594 Meter 1 Meter Density/SG Float 2192 R in gm/cc   R, ‐, R R

8595 Meter 1 Meter Sg Float 2193 R  R, ‐, R R8596 Meter 1 Water Density in kg/m3 (Table 

select 27)Float 2194 R   R, ‐, R R

8597 Meter 1 Current % S&W Float 2195 R/W This register may be written when use Modbus is selected for BS&W input source.

 R/W, ‐, R R

8598 Meter 1 Current CSW Float 2196 R  R, ‐, R R8599 Meter 1 VCF @ 2nd Reference 

TemperatureFloat 2197 R   R, ‐, R R

8601 ‐ 8699 Meter 2 (Same as 8501 ‐ 8599) Float 2199 R  R, ‐, R R8701 ‐ 8799 Meter 3 (Same as 8501 ‐ 8599) Float 21FD R  R, ‐, R8801 ‐ 8899 Meter 4 (Same as 8501 ‐ 8599) Float 2261 R  R, ‐, R R

Floating point (define station)

8901 Station Previous Batch 'n' Avg Temperature

Float 22C5 R   R, ‐, R R

8902 Station Previous Batch 'n' Avg Pressure Float 22C6 R   R, ‐, R R

8903 Station Previous Batch 'n' Avg Density Float 22C7 R Density unit is gm/cc.   R, ‐, R R

8904 Station Previous Batch 'n' Avg VCF Float 22C8 R  R, ‐, R R8905 Station Previous Batch 'n' Avg CPL Float 22C9 R  R, ‐, R R8906 Station Previous Batch 'n' Avg MF Float 22CA R  R, ‐, R R8907 Station Previous Batch 'n' Avg SG Float 22CB R  R, ‐, R R8908 Station Previous Batch 'n' Avg 

SG60/[email protected] 22CC R   R, ‐, R R

Page154 of 229 1/25/2013

Page 155: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8909 Station Previous Batch 'n' Avg Density Temperature

Float 22CD R   R, ‐, R R

8910 Station Previous Batch 'n' Avg Density Pressure

Float 22CE R   R, ‐, R R

8911 Station Prev Batch 'n' Avg DensityCorrectionFactor

Float 22CF R   R, ‐, R R

8912 Station Prev Batch 'n' Avg Unfactored Dens gm/cc

Float 22D0 R Density unit is gm/cc.   R, ‐, R R

8913 Station Previous Batch 'n' Avg K Factor Float 22D1 R   R, ‐, R R

8914 Station Previous Batch 'n' Avg Viscosity Float 22D2 R   R, ‐, R R

8915 Station Previous Batch 'n' Avg LCF Float 22D3 R  R, ‐, R R8916 Station Previous Batch 'n' Avg G. Flowrate Float 22D4 R   R, ‐, R R

8917 Station Previous Batch 'n' Avg %S&W Float 22D5 R  R, ‐, R R8918 Station Previous Batch 'n' Avg Equil 

PressureFloat 22D6 R   R, ‐, R R

8919 Station Previous Batch 'n' Avg API60 Float 22D7 R  R, ‐, R R8920 Station Previous Batch 'n' Avg API Float 22D8 R  R, ‐, R R8921 Reserved8922 Reserved8923 Reserved8924 Reserved8925 Reserved8926 Reserved8927 Station Previous Batch 'n' Avg CTPL Float 22DF R  R, ‐, R R8928 Reserved8929 Reserved8930 Reserved8931 Station Previous Daily Avg Temperature Float 22E3 R  R, ‐, R R8932 Station Previous Daily Avg Pressure Float 22E4 R  R, ‐, R R

Page155 of 229 1/25/2013

Page 156: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8933 Station Previous Daily Avg Density gm/cc Float 22E5 R Density unit is gm/cc.   R, ‐, R R

8934 Station Previous Daily Avg VCF Float 22E6 R  R, ‐, R R8935 Station Previous Daily Avg CPL Float 22E7 R  R, ‐, R R8936 Station Previous Daily Avg Meter Factor Float 22E8 R   R, ‐, R R

8937 Station Previous Daily Avg SG Float 22E9 R  R, ‐, R R8938 Station Previous Daily Avg SG @ 60 Deg.F Float 22EA R   R, ‐, R R

8939 Station Previous Daily Avg Density Temperature

Float 22EB R   R, ‐, R R

8940 Station Previous Daily Avg Density Pressure

Float 22EC R   R, ‐, R R

8941 Station Previous Daily Avg DensityCorrectionFactor

Float 22ED R   R, ‐, R R

8942 Station Prev Daily Avg Unfactored Density gm/cc

Float 22EE R Density unit is gm/cc.   R, ‐, R R

8943 Station Previous Daily Avg K Factor Float 22EF R  R, ‐, R R8944 Station Previous Daily Avg Viscosity Float 22F0 R  R, ‐, R R8945 Station Previous Daily Avg LCF Float 22F1 R  R, ‐, R R8946 Station Previous Daily Avg G. Flowrate Float 22F2 R  R, ‐, R R8947 Station Previous Daily Avg %S&W Float 22F3 R  R, ‐, R R8948 Station Previous Daily Avg Equilibrium 

PressureFloat 22F4 R   R, ‐, R R

8949 Station Previous Daily Gross Total in Float Format

Float 22F5 R   R, ‐, R R

8950 Station Previous Daily Net Total in Float Format

Float 22F6 R   R, ‐, R R

Page156 of 229 1/25/2013

Page 157: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8951 Station Previous Daily Mass Total in Float Format

Float 22F7 R   R, ‐, R R

8952 Station Previous Daily NSV in Float Format

Float 22F8 R   R, ‐, R R

8953 Station Previous Daily 2nd Net in Float Format

Float 22F9 R   R, ‐, R R

8954 Station Previous Daily Avg API Float 22FA R  R, ‐, R R8955 Station Previous Daily Avg API60 Float 22FB R  R, ‐, R R8956 Station Previous Daily Avg CTPL Float 22FC R  R, ‐, R R8957 Reserved8958 Reserved8959 Reserved8960 Reserved8961 Station Current Batch Avg Temperature Float 2301 R  R, ‐, R R8962 Station Current Batch Avg Pressure Float 2302 R  R, ‐, R R8963 Station Current Batch Avg Density gm/cc Float 2303 R Density unit is gm/cc.   R, ‐, R R

8964 Station Current Batch Avg VCF Float 2304 R  R, ‐, R R8965 Station Current Batch Avg CPL Float 2305 R  R, ‐, R R8966 Station Current Batch Avg MF Float 2306 R  R, ‐, R R8967 Station Current Batch Avg SG Float 2307 R  R, ‐, R R8968 Station Current Batch Avg SG @60 Deg.F Float 2308 R  R, ‐, R R8969 Station Current Batch Avg Density 

TemperatureFloat 2309 R   R, ‐, R R

8970 Station Current Batch Avg Density Pressure

Float 230A R   R, ‐, R R

8971 Station Current Batch Avg DensityCorrectionFactor

Float 230B R   R, ‐, R R

8972 Station Current Batch Avg Unfactored Density gm/cc

Float 230C R Density unit is gm/cc.   R, ‐, R R

Page157 of 229 1/25/2013

Page 158: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8973 Station Current Batch Avg K Factor Float 230D R  R, ‐, R R8974 Station Current Batch Avg Viscosity Float 230E R  R, ‐, R R8975 Station Current Batch Avg LCF Float 230F R  R, ‐, R R8976 Station Current Batch Avg Gross Flowrate Float 2310 R   R, ‐, R R

8977 Station Current Batch Avg %S&W Float 2311 R  R, ‐, R R8978 Station Current Batch Avg Equilibrium 

PressureFloat 2312 R   R, ‐, R R

8979 Station Current Batch Avg API60 Float 2313 R  R, ‐, R R8980 Station Current Batch Avg API Float 2314 R  R, ‐, R R8981 Reserved8982 Reserved8983 Reserved8984 Reserved8985 Reserved8986 Station Previous Batch Gross Total in 

Float FormatFloat 231A R   R, ‐, R R

8987 Station Previous Batch Net Total in Float Format

Float 231B R   R, ‐, R R

8988 Station Previous Batch Mass Total in Float Format

Float 231C R   R, ‐, R R

8989 Station Previous Batch Energy/NSV in Float Format

Float 231D R   R, ‐, R R

8990 Station Previous Batch Net Total @ 2nd Ref.T

Float 231E R   R, ‐, R R

8991 Reserved8992 Reserved8993 Reserved8994 Reserved8995 Reserved8996 Reserved

Page158 of 229 1/25/2013

Page 159: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

8997 Reserved8998 Reserved8999 Reserved

9000 index numbers are actually Ascii data buffers (max 5k bytes each)Use function 65 (read) and 66 (write) to access.

9001 Snapshot Report Template Buffer 2329 R/W R/W, ‐, R R9002 Batch Report Template Buffer 232A R/W R/W, ‐, R R9003 Daily Report Template Buffer 232B R/W R/W, ‐, R R9004 Prove Report Template Buffer 232C R/W R/W, ‐, R R

9101 Last Batch Report Buffer 238D R  R, ‐, R R9102 2nd Previous Batch Report Buffer 238E R  R, ‐, R R9103 3rd Previous Batch Report Buffer 238F R  R, ‐, R R9104 4th Previous Batch Report Buffer 2390 R  R, ‐, R R9105 5th Previous Batch Report Buffer 2391 R  R, ‐, R R9106 6th Previous Batch Report Buffer 2392 R  R, ‐, R R9107 7th Previous Batch Report Buffer 2393 R  R, ‐, R R9108 8th Previous Batch Report Buffer 2394 R  R, ‐, R R

9201 Last Prove Report Buffer 23F1 R  R, ‐, R R9202 2nd Previous Prove Report Buffer 23F2 R  R, ‐, R R9203 3rd Previous Prove Report Buffer 23F3 R  R, ‐, R R9204 4th Previous Prove Report Buffer 23F4 R  R, ‐, R R9205 5th Previous Prove Report Buffer 23F5 R  R, ‐, R R9206 6th Previous Prove Report Buffer 23F6 R  R, ‐, R R9207 7th Previous Prove Report Buffer 23F7 R  R, ‐, R R9208 8th Previous Prove Report Buffer 23F8 R  R, ‐, R R

9301 Last Daily Report Buffer 2455 R  R, ‐, R R9302 2nd Previous Daily Report Buffer 2456 R  R, ‐, R R9303 3rd Previous Daily Report Buffer 2457 R  R, ‐, R R9304 4th Previous Daily Report Buffer 2458 R  R, ‐, R R9305 5th Previous Daily Report Buffer 2459 R  R, ‐, R R9306 6th Previous Daily Report Buffer 245A R  R, ‐, R R9307 7th Previous Daily Report Buffer 245B R  R, ‐, R R9308 8th Previous Daily Report Buffer 245C R  R, ‐, R R

Page159 of 229 1/25/2013

Page 160: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

9401 Last Snapshot Report Buffer 24B9 R  R, ‐, R R9402 Modbus Report Transmit Buffer Buffer 24BA R  R, ‐, R R

16 Bit integer data needed by OmniCom

Info: Registers 13001‐18999Flow computer configuration data is especially critical to the correct operation of the flow computer. Any modification of this data while operating the flow computer couldunpredictable results which could cause measurement or control errors.Users are encouraged to consult with OMNI Flow Computer, Inc. before manipulating configuration data directly via a serial port or programmable variable statement.

13001 Meter 1 Flowmeter I/O Point UINT‐16 32C9 R/W R/W, R, R N R13002 Temperature 1 I/O Point UINT‐16 32CA R/W R/W, R, R N R13003 Temperature 1 Type UINT‐16 32CB R/W R/W, R, R N R13004 Pressure 1 I/O Point UINT‐16 32CC R/W R/W, R, R N R13005 Density/Gravity 1 I/O Point UINT‐16 32CD R/W R/W, R, R N R13006 Density/Gravity 1 Type UINT‐16 32CE R/W R/W, R, R N R13007 Density/Gravity 1 Temperature I/O Point UINT‐16 32CF R/W  R/W, R, R N R

13008 Density/Gravity 1 Temperature Type UINT‐16 32D0 R/W R/W, R, R N R13009 Density/Gravity 1 Pressure I/O Point UINT‐16 32D1 R/W R/W, R, R N R13010 Density/Gravity 1 @ Reference Condition 

(Y/N)UINT‐16 32D2 R/W  R/W, R, R N R

13013 Meter 1 Dual Pulse (0=No, 1=Yes) UINT‐16 32D5 R/W R/W, R, R N R13014 Meter 2 Flowmeter I/O Point UINT‐16 32D6 R/W R/W, R, R N R13015 Temperature 2 I/O Point UINT‐16 32D7 R/W R/W, R, R N R13016 Temperature 2 Type UINT‐16 32D8 R/W R/W, R, R N R13017 Pressure 2 I/O Point UINT‐16 32D9 R/W R/W, R, R N R13018 Density/Gravity 2 I/O Point UINT‐16 32DA R/W R/W, R, R N R13019 Density/Gravity 2 Type UINT‐16 32DB R/W R/W, R, R N R13020 Density/Gravity 2 Temperature I/O Point UINT‐16 32DC R/W  R/W, R, R N R

13021 Density/Gravity 2 Temperature Type UINT‐16 32DD R/W R/W, R, R N R13022 Density/Gravity 2 Pressure I/O Point UINT‐16 32DE R/W R/W, R, R N R

Page160 of 229 1/25/2013

Page 161: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13023 Density/Gravity 2 @ Reference Condition (Y/N)

UINT‐16 32DF R/W  R/W, R, R N R

13026 Meter 2 Dual Pulse (0=No, 1=Yes) UINT‐16 32E2 R/W R/W, R, R N R13027 Meter 3 Flowmeter I/O Point UINT‐16 32E3 R/W R/W, R, R N R13028 Temperature 3 I/O Point UINT‐16 32E4 R/W R/W, R, R N R13029 Temperature 3 Type UINT‐16 32E5 R/W R/W, R, R N R13030 Pressure 3 I/O Point UINT‐16 32E6 R/W R/W, R, R N R13031 Density/Gravity 3 I/O Point UINT‐16 32E7 R/W R/W, R, R N R13032 Density/Gravity 3 Type UINT‐16 32E8 R/W R/W, R, R N R13033 Density/Gravity 3 Temperature I/O Point UINT‐16 32E9 R/W  R/W, R, R N R

13034 Density/Gravity 3 Temperature Type UINT‐16 32EA R/W R/W, R, R N R13035 Density/Gravity 3 Pressure I/O Point UINT‐16 32EB R/W R/W, R, R N R13036 Density/Gravity 3 @ Reference Condition 

(Y/N)UINT‐16 32EC R/W  R/W, R, R N R

13039 Meter 3 Dual Pulse (0=No, 1=Yes) UINT‐16 32EF R/W R/W, R, R N R13040 Meter 4 Flowmeter I/O Point UINT‐16 32F0 R/W R/W, R, R N R13041 Temperature 4 I/O Point UINT‐16 32F1 R/W R/W, R, R N R13042 Temperature 4 Type UINT‐16 32F2 R/W R/W, R, R N R13043 Pressure 4 I/O Point UINT‐16 32F3 R/W R/W, R, R N R13044 Density/Gravity 4 I/O Point UINT‐16 32F4 R/W R/W, R, R N R13045 Density/Gravity 4 Type UINT‐16 32F5 R/W R/W, R, R N R13046 Density/Gravity 4 Temperature I/O Point UINT‐16 32F6 R/W  R/W, R, R N R

13047 Density/Gravity 4 Temperature Type UINT‐16 32F7 R/W R/W, R, R N R13048 Density/Gravity 4 Pressure I/O Point UINT‐16 32F8 R/W R/W, R, R N R13049 Density/Gravity 4 @ Reference Condition 

(Y/N)UINT‐16 32F9 R/W  R/W, R, R N R

13052 Meter 4 Dual Pulse (0=No, 1=Yes) UINT‐16 32FC R/W R/W, R, R N R13053 Prover Inlet Temperature I/O Point UINT‐16 32FD R/W R/W, R, R N R13054 Prover Inlet Temperature Type UINT‐16 32FE R/W R/W, R, R N R13055 Prover Outlet Temperature I/O Point UINT‐16 32FF R/W R/W, R, R N R13056 Prover Outlet Temperature Type UINT‐16 3300 R/W R/W, R, R N R

Page161 of 229 1/25/2013

Page 162: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13057 Prover Inlet Pressure I/O Point UINT‐16 3301 R/W R/W, R, R N R13058 Prover Outlet Pressure I/O Point UINT‐16 3302 R/W R/W, R, R N R13059 Prover Plenum Pressure I/O Point UINT‐16 3303 R/W R/W, R, R N R13060 Prover Density Temperature I/O Point UINT‐16 3304 R/W R/W, R, R N R13061 Prover Density Temperature Type UINT‐16 3305 R/W R/W, R, R N R13062 Prover Density Pressure I/O Point UINT‐16 3306 R/W R/W, R, R N R13063 Gravity Sample Time (in Second) UINT‐16 3307 R/W R/W, R, R N R13064 Station Density/Gravity Pressure I/O 

PointUINT‐16 3308 R/W  R/W, R, R N R

13065 Station Density/Gravity I/O Point UINT‐16 3309 R/W R/W, R, R N R13066 Station Density/Gravity Type UINT‐16 330A R/W R/W, R, R N R13067 Station Density/Gravity Temperature I/O 

PointUINT‐16 330B R/W  R/W, R, R N R

13068 Station Density/Gravity Temperature Type

UINT‐16 330C R/W  R/W, R, R N R

13069 Prover Density I/O Point UINT‐16 330D R/W R/W, R, R N R13070 Prover Density Type UINT‐16 330E R/W R/W, ‐, R N R13073 Number of SE Module UINT‐16 3311 R    R,   R, R R13074 Type 0=3000 1=6000 UINT‐16 3312 R    R,   R, R R13075 Number of A Combo Module UINT‐16 3313 R    R, ‐, R R13076 Number of B Combo Module UINT‐16 3314 R    R, ‐, R R13077 Number of C Combo Module UINT‐16 3315 R    R, ‐, R R13078 Number of Digital I/O UINT‐16 3316 R    R, ‐, R R13079 Number of Serial I/O UINT‐16 3317 R    R, ‐, R R13080 Number of E Combo Module UINT‐16 3318 R    R, ‐, R R13081 Number of H Combo Module UINT‐16 3319 R    R, ‐, R R13082 Number of ED Combo Module UINT‐16 331A R    R, ‐, R R13085 Select Serial 1 as Modbus (0=N,1=Y) UINT‐16 331D R/W R/W, ‐, R N R13086 Serial Port ID UINT‐16 331E R    R,   R, R R13087 Serial 1 Baud Rate UINT‐16 331F R/W R/W, ‐, R N R13088 Serial 1 Data Bits UINT‐16 3320 R/W R/W, ‐, R N R13089 Serial 1 Stop Bits UINT‐16 3321 R/W R/W, ‐, R N R13090 Serial 1 Parity UINT‐16 3322 R/W R/W, ‐, R N R13091 Serial 1 Xmit Delay UINT‐16 3323 R/W R/W, ‐, R N R13092 Serial 1 Modbus ID UINT‐16 3324 R/W R/W, ‐, R N R

Page162 of 229 1/25/2013

Page 163: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13093 Serial 1 RTU/Ascii UINT‐16 3325 R/W R/W, ‐, R N R13094 Serial 1 Enable CRC Checking UINT‐16 3326 R/W R/W, ‐, R N R13095 Serial 1 Modicon 984 Compatible UINT‐16 3327 R/W R/W, ‐, R N R13096 Serial 2 Baud Rate UINT‐16 3328 R/W R/W, ‐, R N R13097 Serial 2 Data Bits UINT‐16 3329 R/W R/W, ‐, R N R13098 Serial 2 Stop Bits UINT‐16 332A R/W R/W, ‐, R N R13099 Serial 2 Parity UINT‐16 332B R/W R/W, ‐, R N R13100 Serial 2 Xmit Delay UINT‐16 332C R/W R/W, ‐, R N R13101 Serial 2 Modbus ID UINT‐16 332D R/W R/W, ‐, R N R13102 Serial 2 RTU/Ascii UINT‐16 332E R/W R/W, ‐, R N R13103 Serial 2 Enable CRC Checking UINT‐16 332F R/W R/W, ‐, R N R13104 Serial 2 Modicon 984 Compatible UINT‐16 3330 R/W R/W, ‐, R N R13105 Number of HART HT Module UINT‐16 3331 R   R, R, R R13108 Serial 3 Baud Rate UINT‐16 3334 R/W R/W, ‐, R N R13109 Serial 3 Data Bits UINT‐16 3335 R/W R/W, ‐, R N R13110 Serial 3 Stop Bits UINT‐16 3336 R/W R/W, ‐, R N R13111 Serial 3 Parity UINT‐16 3337 R/W R/W, ‐, R N R13112 Serial 3 Xmit Delay UINT‐16 3338 R/W R/W, ‐, R N R13113 Serial 3 Modbus ID UINT‐16 3339 R/W R/W, ‐, R N R13114 Serial 3 Protocol Type UINT‐16 333A R/W R/W, ‐, R N R13115 Serial 3 Enable CRC Checking UINT‐16 333B R/W R/W, ‐, R N R13116 Serial 3 Modicon 984 Compatible UINT‐16 333C R/W R/W, ‐, R N R13117 Number of HART HM Module UINT‐16 333D R   R, R,         R R13118 Switch Bar Temperature I/O Point UINT‐16 333E R/W R/W, ‐, R N R13119 Switch Bar Temperature I/O Type UINT‐16 333F R/W R/W, ‐, R N R13120 Serial 4 Baud Rate UINT‐16 3340 R/W R/W, ‐, R N R13121 Serial 4 Data Bits UINT‐16 3341 R/W R/W, ‐, R N R13122 Serial 4 Stop Bits UINT‐16 3342 R/W R/W, ‐, R N R13123 Serial 4 Parity UINT‐16 3343 R/W R/W, ‐, R N R13124 Serial 4 Xmit Delay UINT‐16 3344 R/W R/W, ‐, R N R13125 Serial 4 CRC Checking UINT‐16 3345 R/W R/W, ‐, R N R13126 Serial 4 ID UINT‐16 3346 R/W R/W, ‐, R N R13127 Serial 4 Protocol Type UINT‐16 3347 R/W R/W, ‐, R N R13128 Serial 4 Modicon 984 or BCC/CRC Sel UINT‐16 3348 R/W R/W, ‐, R N R13129 PID 1 Remote Setpt Assign Pt UINT‐16 3349 R/W R/W, ‐, R N R13130 PID 1 Primary Assign Pt UINT‐16 334A R/W R/W, ‐, R N R13131 PID 1 Secondary Assign Pt UINT‐16 334B R/W R/W, ‐, R N R13132 PID 1 Primary Action 0=Fwd 1=Rev UINT‐16 334C R/W R/W, ‐, R N R

Page163 of 229 1/25/2013

Page 164: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13133 PID 1 Secondary Action 0=Fwd 1=Rev UINT‐16 334D R/W R/W, ‐, R N R13134 PID 1 Error Select 0=Lo 1=Hi UINT‐16 334E R/W R/W, ‐, R N R13135 PID 1 Startup Mode  0=Last 1=Manual UINT‐16 334F R/W R/W, ‐, R N R13136 PID 2 Remote Setpt Assign Pt UINT‐16 3350 R/W R/W, ‐, R N R13137 PID 2 Primary Assign Pt UINT‐16 3351 R/W R/W, ‐, R N R13138 PID 2 Secondary Assign Pt UINT‐16 3352 R/W R/W, ‐, R N R13139 PID 2 Primary Action 0=Fwd 1=Rev UINT‐16 3353 R/W R/W, ‐, R N R13140 PID 2 Secondary Action 0=Fwd 1=Rev UINT‐16 3354 R/W R/W, ‐, R N R13141 PID 2 Error Select 0=Lo 1=Hi UINT‐16 3355 R/W R/W, ‐, R N R13142 PID 2 Startup Mode  0=Last  1=Manual UINT‐16 3356 R/W R/W, ‐, R N R13143 PID 3 Remote Setpt Assign Pt UINT‐16 3357 R/W R/W, ‐, R N R13144 PID 3 Primary Assign Pt UINT‐16 3358 R/W R/W, ‐, R N R13145 PID 3 Secondary Assign Pt UINT‐16 3359 R/W R/W, ‐, R N R13146 PID 3 Primary Action 0=Fwd 1=Rev UINT‐16 335A R/W R/W, ‐, R N R13147 PID 3 Secondary Action 0=Fwd 1=Rev UINT‐16 335B R/W R/W, ‐, R N R13148 PID 3 Error Select 0=Lo 1=Hi UINT‐16 335C R/W R/W, ‐, R N R13149 PID 3 Startup Mode  0=Last  1=Manual UINT‐16 335D R/W R/W, ‐, R N R13150 PID 4 Remote Setpt Assign Pt UINT‐16 335E R/W R/W, ‐, R N R13151 PID 4 Primary Assign Pt UINT‐16 335F R/W R/W, ‐, R N R13152 PID 4 Secondary Assign Pt UINT‐16 3360 R/W R/W, ‐, R N R13153 PID 4 Primary Action 0=Fwd 1=Rev UINT‐16 3361 R/W R/W, ‐, R N R13154 PID 4 Secondary Action 0=Fwd 1=Rev UINT‐16 3362 R/W R/W, ‐, R N R13155 PID 4 Error Select 0=Lo 1=Hi UINT‐16 3363 R/W R/W, ‐, R N R13156 PID 4 Startup Mode  0=Last  1=Manual UINT‐16 3364 R/W R/W, ‐, R N R

13157 Auxiliary Input 1 I/O Point UINT‐16 3365 R/W R/W, R, R N R13158 Auxiliary Input 2 I/O Point UINT‐16 3366 R/W R/W, R, R N R13159 Auxiliary Input 3 I/O Point UINT‐16 3367 R/W R/W, R, R N R13160 Auxiliary Input 4 I/O Point UINT‐16 3368 R/W R/W, R, R N R13161 PLC Group 1 Starting Address UINT‐16 3369 R/W R/W, ‐, R N R13162 PLC Group 1 Index 1 UINT‐16 336A R/W R/W, ‐, R N R13163 PLC Group 1 Number of Points 1 UINT‐16 336B R/W R/W, ‐, R N R13164 PLC Group 1 Index 2 UINT‐16 336C R/W R/W, ‐, R N R13165 PLC Group 1 Number of Points 2 UINT‐16 336D R/W R/W, ‐, R N R13166 PLC Group 1 Index 3 UINT‐16 336E R/W R/W, ‐, R N R13167 PLC Group 1 Number of Points 3 UINT‐16 336F R/W R/W, ‐, R N R13168 PLC Group 1 Index 4 UINT‐16 3370 R/W R/W, ‐, R N R13169 PLC Group 1 Number of Points 4 UINT‐16 3371 R/W R/W, ‐, R N R

Page164 of 229 1/25/2013

Page 165: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13170 PLC Group 1 Index 5 UINT‐16 3372 R/W R/W, ‐, R N R13171 PLC Group 1 Number of Points 5 UINT‐16 3373 R/W R/W, ‐, R N R13172 PLC Group 1 Index 6 UINT‐16 3374 R/W R/W, ‐, R N R13173 PLC Group 1 Number of Points 6 UINT‐16 3375 R/W R/W, ‐, R N R13174 PLC Group 1 Index 7 UINT‐16 3376 R/W R/W, ‐, R N R13175 PLC Group 1 Number of Points 7 UINT‐16 3377 R/W R/W, ‐, R N R13176 PLC Group 1 Index 8 UINT‐16 3378 R/W R/W, ‐, R N R13177 PLC Group 1 Number of Points 8 UINT‐16 3379 R/W R/W, ‐, R N R13178 PLC Group 1 Index 9 UINT‐16 337A R/W R/W, ‐, R N R13179 PLC Group 1 Number of Points 9 UINT‐16 337B R/W R/W, ‐, R N R13180 PLC Group 1 Index 10 UINT‐16 337C R/W R/W, ‐, R N R13181 PLC Group 1 Number of Points 10 UINT‐16 337D R/W R/W, ‐, R N R13182 PLC Group 1 Index 11 UINT‐16 337E R/W R/W, ‐, R N R13183 PLC Group 1 Number of Points 11 UINT‐16 337F R/W R/W, ‐, R N R13184 PLC Group 1 Index 12 UINT‐16 3380 R/W R/W, ‐, R N R13185 PLC Group 1 Number of Points 12 UINT‐16 3381 R/W R/W, ‐, R N R13186 PLC Group 1 Index 13 UINT‐16 3382 R/W R/W, ‐, R N R13187 PLC Group 1 Number of Points 13 UINT‐16 3383 R/W R/W, ‐, R N R13188 PLC Group 1 Index 14 UINT‐16 3384 R/W R/W, ‐, R N R13189 PLC Group 1 Number of Points 14 UINT‐16 3385 R/W R/W, ‐, R N R13190 PLC Group 1 Index 15 UINT‐16 3386 R/W R/W, ‐, R N R13191 PLC Group 1 Number of Points 15 UINT‐16 3387 R/W R/W, ‐, R N R13192 PLC Group 1 Index 16 UINT‐16 3388 R/W R/W, ‐, R N R13193 PLC Group 1 Number of Points 16 UINT‐16 3389 R/W R/W, ‐, R N R13194 PLC Group 2 Starting Address UINT‐16 338A R/W R/W, ‐, R N R13195 PLC Group 2 Index 1 UINT‐16 338B R/W R/W, ‐, R N R13196 PLC Group 2 Number of Points 1 UINT‐16 338C R/W R/W, ‐, R N R13197 PLC Group 2 Index 2 UINT‐16 338D R/W R/W, ‐, R N R13198 PLC Group 2 Number of Points 2 UINT‐16 338E R/W R/W, ‐, R N R13199 PLC Group 2 Index 3 UINT‐16 338F R/W R/W, ‐, R N R13200 PLC Group 2 Number of Points 3 UINT‐16 3390 R/W R/W, ‐, R N R13201 PLC Group 2 Index 4 UINT‐16 3391 R/W R/W, ‐, R N R13202 PLC Group 2 Number of Points 4 UINT‐16 3392 R/W R/W, ‐, R N R13203 PLC Group 2 Index 5 UINT‐16 3393 R/W R/W, ‐, R N R13204 PLC Group 2 Number of Points 5 UINT‐16 3394 R/W R/W, ‐, R N R13205 PLC Group 2 Index 6 UINT‐16 3395 R/W R/W, ‐, R N R13206 PLC Group 2 Number of Points 6 UINT‐16 3396 R/W R/W, ‐, R N R13207 PLC Group 2 Index 7 UINT‐16 3397 R/W R/W, ‐, R N R

Page165 of 229 1/25/2013

Page 166: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13208 PLC Group 2 Number of Points 7 UINT‐16 3398 R/W R/W, ‐, R N R13209 PLC Group 2 Index 8 UINT‐16 3399 R/W R/W, ‐, R N R13210 PLC Group 2 Number of Points 8 UINT‐16 339A R/W R/W, ‐, R N R13211 PLC Group 2 Index 9 UINT‐16 339B R/W R/W, ‐, R N R13212 PLC Group 2 Number of Points 9 UINT‐16 339C R/W R/W, ‐, R N R13213 PLC Group 2 Index 10 UINT‐16 339D R/W R/W, ‐, R N R13214 PLC Group 2 Number of Points 10 UINT‐16 339E R/W R/W, ‐, R N R13215 PLC Group 2 Index 11 UINT‐16 339F R/W R/W, ‐, R N R13216 PLC Group 2 Number of Points 11 UINT‐16 33A0 R/W R/W, ‐, R N R13217 PLC Group 2 Index 12 UINT‐16 33A1 R/W R/W, ‐, R N R13218 PLC Group 2 Number of Points 12 UINT‐16 33A2 R/W R/W, ‐, R N R13219 PLC Group 2 Index 13 UINT‐16 33A3 R/W R/W, ‐, R N R13220 PLC Group 2 Number of Points 13 UINT‐16 33A4 R/W R/W, ‐, R N R13221 PLC Group 2 Index 14 UINT‐16 33A5 R/W R/W, ‐, R N R13222 PLC Group 2 Number of Points 14 UINT‐16 33A6 R/W R/W, ‐, R N R13223 PLC Group 2 Index 15 UINT‐16 33A7 R/W R/W, ‐, R N R13224 PLC Group 2 Number of Points 15 UINT‐16 33A8 R/W R/W, ‐, R N R13225 PLC Group 2 Index 16 UINT‐16 33A9 R/W R/W, ‐, R N R13226 PLC Group 2 Number of Points 16 UINT‐16 33AA R/W R/W, ‐, R N R13227 PLC Group 3 Starting Address UINT‐16 33AB R/W R/W, ‐, R N R13228 PLC Group 3 Index 1 UINT‐16 33AC R/W R/W, ‐, R N R13229 PLC Group 3 Number of Points 1 UINT‐16 33AD R/W R/W, ‐, R N R13230 PLC Group 3 Index 2 UINT‐16 33AE R/W R/W, ‐, R N R13231 PLC Group 3 Number of Points 2 UINT‐16 33AF R/W R/W, ‐, R N R13232 PLC Group 3 Index 3 UINT‐16 33B0 R/W R/W, ‐, R N R13233 PLC Group 3 Number of Points 3 UINT‐16 33B1 R/W R/W, ‐, R N R13234 PLC Group 3 Index 4 UINT‐16 33B2 R/W R/W, ‐, R N R13235 PLC Group 3 Number of Points 4 UINT‐16 33B3 R/W R/W, ‐, R N R13236 PLC Group 3 Index 5 UINT‐16 33B4 R/W R/W, ‐, R N R13237 PLC Group 3 Number of Points 5 UINT‐16 33B5 R/W R/W, ‐, R N R13238 PLC Group 3 Index 6 UINT‐16 33B6 R/W R/W, ‐, R N R13239 PLC Group 3 Number of Points 6 UINT‐16 33B7 R/W R/W, ‐, R N R13240 PLC Group 3 Index 7 UINT‐16 33B8 R/W R/W, ‐, R N R13241 PLC Group 3 Number of Points 7 UINT‐16 33B9 R/W R/W, ‐, R N R13242 PLC Group 3 Index 8 UINT‐16 33BA R/W R/W, ‐, R N R13243 PLC Group 3 Number of Points 8 UINT‐16 33BB R/W R/W, ‐, R N R13244 PLC Group 3 Index 9 UINT‐16 33BC R/W R/W, ‐, R N R13245 PLC Group 3 Number of Points 9 UINT‐16 33BD R/W R/W, ‐, R N R

Page166 of 229 1/25/2013

Page 167: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13246 PLC Group 3 Index 10 UINT‐16 33BE R/W R/W, ‐, R N R13247 PLC Group 3 Number of Points 10 UINT‐16 33BF R/W R/W, ‐, R N R13248 PLC Group 3 Index 11 UINT‐16 33C0 R/W R/W, ‐, R N R13249 PLC Group 3 Number of Points 11 UINT‐16 33C1 R/W R/W, ‐, R N R13250 PLC Group 3 Index 12 UINT‐16 33C2 R/W R/W, ‐, R N R13251 PLC Group 3 Number of Points 12 UINT‐16 33C3 R/W R/W, ‐, R N R13252 PLC Group 3 Index 13 UINT‐16 33C4 R/W R/W, ‐, R N R13253 PLC Group 3 Number of Points 13 UINT‐16 33C5 R/W R/W, ‐, R N R13254 PLC Group 3 Index 14 UINT‐16 33C6 R/W R/W, ‐, R N R13255 PLC Group 3 Number of Points 14 UINT‐16 33C7 R/W R/W, ‐, R N R13256 PLC Group 3 Index 15 UINT‐16 33C8 R/W R/W, ‐, R N R13257 PLC Group 3 Number of Points 15 UINT‐16 33C9 R/W R/W, ‐, R N R13258 PLC Group 3 Index 16 UINT‐16 33CA R/W R/W, ‐, R N R13259 PLC Group 3 Number of Points 16 UINT‐16 33CB R/W R/W, ‐, R N R13260 PLC Group 4 Starting Address UINT‐16 33CC R/W R/W, ‐, R N R13261 PLC Group 4 Index 1 UINT‐16 33CD R/W R/W, ‐, R N R13262 PLC Group 4 Number of Points 1 UINT‐16 33CE R/W R/W, ‐, R N R13263 PLC Group 4 Index 2 UINT‐16 33CF R/W R/W, ‐, R N R13264 PLC Group 4 Number of Points 2 UINT‐16 33D0 R/W R/W, ‐, R N R13265 PLC Group 4 Index 3 UINT‐16 33D1 R/W R/W, ‐, R N R13266 PLC Group 4 Number of Points 3 UINT‐16 33D2 R/W R/W, ‐, R N R13267 PLC Group 4 Index 4 UINT‐16 33D3 R/W R/W, ‐, R N R13268 PLC Group 4 Number of Points 4 UINT‐16 33D4 R/W R/W, ‐, R N R13269 PLC Group 4 Index 5 UINT‐16 33D5 R/W R/W, ‐, R N R13270 PLC Group 4 Number of Points 5 UINT‐16 33D6 R/W R/W, ‐, R N R13271 PLC Group 4 Index 6 UINT‐16 33D7 R/W R/W, ‐, R N R13272 PLC Group 4 Number of Points 6 UINT‐16 33D8 R/W R/W, ‐, R N R13273 PLC Group 5 Starting Address UINT‐16 33D9 R/W R/W, ‐, R N R13274 PLC Group 5 Index 1 UINT‐16 33DA R/W R/W, ‐, R N R13275 PLC Group 5 Number of Points 1 UINT‐16 33DB R/W R/W, ‐, R N R13276 PLC Group 5 Index 2 UINT‐16 33DC R/W R/W, ‐, R N R13277 PLC Group 5 Number of Points 2 UINT‐16 33DD R/W R/W, ‐, R N R13278 PLC Group 5 Index 3 UINT‐16 33DE R/W R/W, ‐, R N R13279 PLC Group 5 Number of Points 3 UINT‐16 33DF R/W R/W, ‐, R N R13280 PLC Group 5 Index 4 UINT‐16 33E0 R/W R/W, ‐, R N R13281 PLC Group 5 Number of Points 4 UINT‐16 33E1 R/W R/W, ‐, R N R13282 PLC Group 5 Index 5 UINT‐16 33E2 R/W R/W, ‐, R N R13283 PLC Group 5 Number of Points 5 UINT‐16 33E3 R/W R/W, ‐, R N R

Page167 of 229 1/25/2013

Page 168: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13284 PLC Group 5 Index 6 UINT‐16 33E4 R/W R/W, ‐, R N R13285 PLC Group 5 Number of Points 6 UINT‐16 33E5 R/W R/W, ‐, R N R13289 Meter 1 Mass Pulses (0=N,1=Y) UINT‐16 33E9 R/W R/W, R, R N R13290 Meter 2 Mass Pulses (0=N,1=Y) UINT‐16 33EA R/W R/W, R, R N R13291 Meter 3 Mass Pulses (0=N,1=Y) UINT‐16 33EB R/W R/W, R, R N R13292 Meter 4 Mass Pulses (0=N,1=Y) UINT‐16 33EC R/W R/W, R, R N R13293 Auxiliary Input 1 Type UINT‐16 33ED R/W R/W, ‐, R N R13294 Auxiliary Input 2 Type UINT‐16 33EE R/W R/W, ‐, R N R13295 Auxiliary Input 3 Type UINT‐16 33EF R/W R/W, ‐, R N R13296 Auxiliary Input 4 Type UINT‐16 33F0 R/W R/W, ‐, R N R13297 Start Batch with Current Time/Date Even 

Meter is Not Active(Y/N)UINT‐16 33F1 R/W  R/W, ‐, R Y R

13298 Reserved13299 Reserved13300 Next Master ID (For Peer to Peer) UINT‐16 33F4 R/W R/W, ‐, R R13301 Current Master ID (For Peer to Peer) UINT‐16 33F5 R/W R/W, ‐, R R13302 Peer/Peer 1 Slave ID UINT‐16 33F6 R/W R/W, ‐, R N R13303 Peer/Peer 1 Read/Write UINT‐16 33F7 R/W R/W, ‐, R N R13304 Peer/Peer 1 Source Index UINT‐16 33F8 R/W R/W, ‐, R N R13305 Peer/Peer 1 Number of Points UINT‐16 33F9 R/W R/W, ‐, R N R13306 Peer/Peer 1 Destination Index UINT‐16 33FA R/W R/W, ‐, R N R13307 Peer/Peer 2 Slave ID UINT‐16 33FB R/W R/W, ‐, R N R13308 Peer/Peer 2 Read/Write UINT‐16 33FC R/W R/W, ‐, R N R13309 Peer/Peer 2 Source Index UINT‐16 33FD R/W R/W, ‐, R N R13310 Peer/Peer 2 Number of Points UINT‐16 33FE R/W R/W, ‐, R N R13311 Peer/Peer 2 Destination Index UINT‐16 33FF R/W R/W, ‐, R N R13312 Peer/Peer 3 Slave ID UINT‐16 3400 R/W R/W, ‐, R N R13313 Peer/Peer 3 Read/Write UINT‐16 3401 R/W R/W, ‐, R N R13314 Peer/Peer 3 Source Index UINT‐16 3402 R/W R/W, ‐, R N R13315 Peer/Peer 3 Number of Points UINT‐16 3403 R/W R/W, ‐, R N R13316 Peer/Peer 3 Destination Index UINT‐16 3404 R/W R/W, ‐, R N R13317 Peer/Peer 4 Slave ID UINT‐16 3405 R/W R/W, ‐, R N R13318 Peer/Peer 4 Read/Write UINT‐16 3406 R/W R/W, ‐, R N R13319 Peer/Peer 4 Source Index UINT‐16 3407 R/W R/W, ‐, R N R13320 Peer/Peer 4 Number of Points UINT‐16 3408 R/W R/W, ‐, R N R13321 Peer/Peer 4 Destination Index UINT‐16 3409 R/W R/W, ‐, R N R13322 Peer/Peer 5 Slave ID UINT‐16 340A R/W R/W, ‐, R N R

Page168 of 229 1/25/2013

Page 169: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13323 Peer/Peer 5 Read/Write UINT‐16 340B R/W R/W, ‐, R N R13324 Peer/Peer 5 Source Index UINT‐16 340C R/W R/W, ‐, R N R13325 Peer/Peer 5 Number of Points UINT‐16 340D R/W R/W, ‐, R N R13326 Peer/Peer 5 Destination Index UINT‐16 340E R/W R/W, ‐, R N R13327 Peer/Peer 6 Slave ID UINT‐16 340F R/W R/W, ‐, R N R13328 Peer/Peer 6 Read/Write UINT‐16 3410 R/W R/W, ‐, R N R13329 Peer/Peer 6 Source Index UINT‐16 3411 R/W R/W, ‐, R N R13330 Peer/Peer 6 Number of Points UINT‐16 3412 R/W R/W, ‐, R N R13331 Peer/Peer 6 Destination Index UINT‐16 3413 R/W R/W, ‐, R N R13332 Peer/Peer 7 Slave ID UINT‐16 3414 R/W R/W, ‐, R N R13333 Peer/Peer 7 Read/Write UINT‐16 3415 R/W R/W, ‐, R N R13334 Peer/Peer 7 Source Index UINT‐16 3416 R/W R/W, ‐, R N R13335 Peer/Peer 7 Number of Points UINT‐16 3417 R/W R/W, ‐, R N R13336 Peer/Peer 7 Destination Index UINT‐16 3418 R/W R/W, ‐, R N R13337 Peer/Peer 8 Slave ID UINT‐16 3419 R/W R/W, ‐, R N R13338 Peer/Peer 8 Read/Write UINT‐16 341A R/W R/W, ‐, R N R13339 Peer/Peer 8 Source Index UINT‐16 341B R/W R/W, ‐, R N R13340 Peer/Peer 8 Number of Points UINT‐16 341C R/W R/W, ‐, R N R13341 Peer/Peer 8 Destination Index UINT‐16 341D R/W R/W, ‐, R N R13342 Peer/Peer 9 Slave ID UINT‐16 341E R/W R/W, ‐, R N R13343 Peer/Peer 9 Read/Write UINT‐16 341F R/W R/W, ‐, R N R13344 Peer/Peer 9 Source Index UINT‐16 3420 R/W R/W, ‐, R N R13345 Peer/Peer 9 Number of Points UINT‐16 3421 R/W R/W, ‐, R N R13346 Peer/Peer 9 Destination Index UINT‐16 3422 R/W R/W, ‐, R N R13347 Peer/Peer 10 Slave ID UINT‐16 3423 R/W R/W, ‐, R N R13348 Peer/Peer 10 Read/Write UINT‐16 3424 R/W R/W, ‐, R N R13349 Peer/Peer 10 Source Index UINT‐16 3425 R/W R/W, ‐, R N R13350 Peer/Peer 10 Number of Points UINT‐16 3426 R/W R/W, ‐, R N R13351 Peer/Peer 10 Destination Index UINT‐16 3427 R/W R/W, ‐, R N R13352 Peer/Peer 11 Slave ID UINT‐16 3428 R/W R/W, ‐, R N R13353 Peer/Peer 11 Read/Write UINT‐16 3429 R/W R/W, ‐, R N R13354 Peer/Peer 11 Source Index UINT‐16 342A R/W R/W, ‐, R N R13355 Peer/Peer 11 Number of Points UINT‐16 342B R/W R/W, ‐, R N R13356 Peer/Peer 11 Destination Index UINT‐16 342C R/W R/W, ‐, R N R13357 Peer/Peer 12 Slave ID UINT‐16 342D R/W R/W, ‐, R N R13358 Peer/Peer 12 Read/Write UINT‐16 342E R/W R/W, ‐, R N R13359 Peer/Peer 12 Source Index UINT‐16 342F R/W R/W, ‐, R N R13360 Peer/Peer 12 Number of Points UINT‐16 3430 R/W R/W, ‐, R N R

Page169 of 229 1/25/2013

Page 170: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13361 Peer/Peer 12 Destination Index UINT‐16 3431 R/W R/W, ‐, R N R13362 Peer/Peer 13 Slave ID UINT‐16 3432 R/W R/W, ‐, R N R13363 Peer/Peer 13 Read/Write UINT‐16 3433 R/W R/W, ‐, R N R13364 Peer/Peer 13 Source Index UINT‐16 3434 R/W R/W, ‐, R N R13365 Peer/Peer 13 Number of Points UINT‐16 3435 R/W R/W, ‐, R N R13366 Peer/Peer 13 Destination Index UINT‐16 3436 R/W R/W, ‐, R N R13367 Peer/Peer 14 Slave ID UINT‐16 3437 R/W R/W, ‐, R N R13368 Peer/Peer 14 Read/Write UINT‐16 3438 R/W R/W, ‐, R N R13369 Peer/Peer 14 Source Index UINT‐16 3439 R/W R/W, ‐, R N R13370 Peer/Peer 14 Number of Points UINT‐16 343A R/W R/W, ‐, R N R13371 Peer/Peer 14 Destination Index UINT‐16 343B R/W R/W, ‐, R N R13372 Peer/Peer 15 Slave ID UINT‐16 343C R/W R/W, ‐, R N R13373 Peer/Peer 15 Read/Write UINT‐16 343D R/W R/W, ‐, R N R13374 Peer/Peer 15 Source Index UINT‐16 343E R/W R/W, ‐, R N R13375 Peer/Peer 15 Number of Points UINT‐16 343F R/W R/W, ‐, R N R13376 Peer/Peer 15 Destination Index UINT‐16 3440 R/W R/W, ‐, R N R13377 Peer/Peer 16 Slave ID UINT‐16 3441 R/W R/W, ‐, R N R13378 Peer/Peer 16 Read/Write UINT‐16 3442 R/W R/W, ‐, R N R13379 Peer/Peer 16 Source Index UINT‐16 3443 R/W R/W, ‐, R N R13380 Peer/Peer 16 Number of Points UINT‐16 3444 R/W R/W, ‐, R N R13381 Peer/Peer 16 Destination Index UINT‐16 3445 R/W R/W, ‐, R N R13382 Next Master ID in Peer to Peer Comm UINT‐16 3446 R/W R/W, ‐, R N R13383 Maximum Number of Units in Peer/Peer UINT‐16 3447 R/W R/W, ‐, R N R13384 Retry Timer Peer/Peer UINT‐16 3448 R/W R/W, ‐, R N R13385 Activate Redundancy UINT‐16 3449 R/W R/W, ‐, R N R13386 Decimal Places for Gross Totalizer UINT‐16 344A R/W R/W, R, R N R13388 Decimal Places for Mass Totalizer UINT‐16 344C R/W R/W, R, R N R13390 Decimal Places of Factors Batch Rpt UINT‐16 344E R/W R/W, R, R N R13391 Decimal Places of MF Batch Report UINT‐16 344F R/W R/W, R, R N R13392 Decimal Places of Factors Prove Rpt UINT‐16 3450 R/W R/W, R, R N R13393 Decimal Places of MF Prove Report UINT‐16 3451 R/W R/W, R, R N R13395 Peer to Peer Default Mastership When 

Power Up(0=No,1=Yes)UINT‐16 3453 R/W  R/W, ‐, R N R

13396 Auxiliary Input 1 Override Code UINT‐16 3454 R/W R/W, ‐, R Y R13397 Auxiliary Input 2 Override Code UINT‐16 3455 R/W R/W, ‐, R Y R13398 Auxiliary Input 3 Override Code UINT‐16 3456 R/W R/W, ‐, R Y R13399 Auxiliary Input 4 Override Code UINT‐16 3457 R/W R/W, ‐, R Y R

Page170 of 229 1/25/2013

Page 171: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13402 Temperature 1 Damping Code UINT‐16 345A R/W R/W, ‐, R N R13403 Pressure 1 Damping Code UINT‐16 345B R/W R/W, ‐, R N R13404 Density Temperature 1 Damping Code UINT‐16 345C R/W R/W, ‐, R N R13405 Density Pressure 1 Damping Code UINT‐16 345D R/W R/W, ‐, R N R13408 Temperature 2 Damping Code UINT‐16 3460 R/W R/W, ‐, R N R13409 Pressure 2 Damping Code UINT‐16 3461 R/W R/W, ‐, R N R13410 Density Temperature 2 Damping Code UINT‐16 3462 R/W R/W, ‐, R N R13411 Density Pressure 2 Damping Code UINT‐16 3463 R/W R/W, ‐, R N R13414 Temperature 3 Damping Code UINT‐16 3466 R/W R/W, ‐, R N R13415 Pressure 3 Damping Code UINT‐16 3467 R/W R/W, ‐, R N R13416 Density Temperature 3 Damping Code UINT‐16 3468 R/W R/W, ‐, R N R13417 Density Pressure 3 Damping Code UINT‐16 3469 R/W R/W, ‐, R N R13420 Temperature 4 Damping Code UINT‐16 346C R/W R/W, ‐, R N R13421 Pressure 4 Damping Code UINT‐16 346D R/W R/W, ‐, R N R13422 Density Temperature 4 Damping Code UINT‐16 346E R/W R/W, ‐, R N R13423 Density Pressure 4 Damping Code UINT‐16 346F R/W R/W, ‐, R N R13424 Station Density Temp Damping Code UINT‐16 3470 R/W R/W, ‐, R N R13425 Station Density Pres Damping Code UINT‐16 3471 R/W R/W, ‐, R N R13426 Inlet Temperature Damping Code UINT‐16 3472 R/W R/W, ‐, R N R13427 Outlet Temperature Damping Code UINT‐16 3473 R/W R/W, ‐, R N R13428 Inlet Pressure Damping Code UINT‐16 3474 R/W R/W, ‐, R N R13429 Outlet Pressure Damping Code UINT‐16 3475 R/W R/W, ‐, R N R13430 Plenum Pressure Damping Code UINT‐16 3476 R/W R/W, ‐, R N R13431 Prover Density Temp Damping Code UINT‐16 3477 R/W R/W, ‐, R N R13432 Prover Density Pressure Damping Code UINT‐16 3478 R/W R/W, ‐, R N R13433 Auxiliary Input 1 Damping Code UINT‐16 3479 R/W R/W, ‐, R N R13434 Auxiliary Input 2 Damping Code UINT‐16 347A R/W R/W, ‐, R N R13435 Auxiliary Input 3 Damping Code UINT‐16 347B R/W R/W, ‐, R N R13436 Auxiliary Input 4 Damping Code UINT‐16 347C R/W R/W, ‐, R N R13437 Enable Alarm Checking When Meter 1 

InactiveUINT‐16 347D R/W  R/W, ‐, R N R

13438 Enable Alarm Checking When Meter 2 Inactive

UINT‐16 347E R/W  R/W, ‐, R N R

13439 Enable Alarm Checking When Meter 3 Inactive

UINT‐16 347F R/W  R/W, ‐, R N R

Page171 of 229 1/25/2013

Page 172: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13440 Enable Alarm Checking When Meter 4 Inactive

UINT‐16 3480 R/W  R/W, ‐, R N R

13441 Switch Bar Temperature Damping Code UINT‐16 3481 R/W R/W, ‐, R N R13449 Default Status Screen (0=No, 1=Yes) UINT‐16 3489 R/W R/W, ‐, R N R13450 Insert Batch Stack Meter 1 UINT‐16 348A R/W R/W, R/W, R Y R13451 Insert Batch Stack Meter 2 UINT‐16 348B R/W R/W, R/W, R Y R13452 Insert Batch Stack Meter 3 UINT‐16 348C R/W R/W, R/W, R Y R13453 Insert Batch Stack Meter 4 UINT‐16 348D R/W R/W, R/W, R Y R13454 Insert Batch Stack Station UINT‐16 348E R/W R/W, R/W, R Y R13455 Delete Batch Stack Meter 1 UINT‐16 348F R/W R/W, R/W, R Y R13456 Delete Batch Stack Meter 2 UINT‐16 3490 R/W R/W, R/W, R Y R13457 Delete Batch Stack Meter 3 UINT‐16 3491 R/W R/W, R/W, R Y R13458 Delete Batch Stack Meter 4 UINT‐16 3492 R/W R/W, R/W, R Y R13459 Delete Batch Stack Station UINT‐16 3493 R/W R/W, R/W, R Y R13460 Remote Key Press UINT‐16 3494 R/W R/W, R/W, R/W R13461 Beep Counts UINT‐16 3495 R/W R/W, ‐, R R13462 Redundancy Master PID 1 Valve Mode UINT‐16 3496 R/W R/W, ‐, R R13463 Redundancy Master PID 1 Setpt Mode UINT‐16 3497 R/W R/W, ‐, R R13464 Redundancy Master PID 2 Valve Mode UINT‐16 3498 R/W R/W, ‐, R R13465 Redundancy Master PID 2 Setpt Mode UINT‐16 3499 R/W R/W, ‐, R R13466 Redundancy Master PID 3 Valve Mode UINT‐16 349A R/W R/W, ‐, R R13467 Redundancy Master PID 3 Setpt Mode UINT‐16 349B R/W R/W, ‐, R R13468 Redundancy Master PID 4 Valve Mode UINT‐16 349C R/W R/W, ‐, R R13469 Redundancy Master PID 4 Setpt Mode UINT‐16 349D R/W R/W, ‐, R R13470 Redundancy Slave PID 1 Valve Mode UINT‐16 349E R/W R/W, ‐, R R13471 Redundancy Slave PID 1 Setpt Mode UINT‐16 349F R/W R/W, ‐, R R13472 Redundancy Slave PID 2 Valve Mode UINT‐16 34A0 R/W R/W, ‐, R R13473 Redundancy Slave PID 2 Setpt Mode UINT‐16 34A1 R/W R/W, ‐, R R13474 Redundancy Slave PID 3 Valve Mode UINT‐16 34A2 R/W R/W, ‐, R R13475 Redundancy Slave PID 3 Setpt Mode UINT‐16 34A3 R/W R/W, ‐, R R13476 Redundancy Slave PID 4 Valve Mode UINT‐16 34A4 R/W R/W, ‐, R R13477 Redundancy Slave PID 4 Setpt Mode UINT‐16 34A5 R/W R/W, ‐, R R13478 Serial 5 Baud Rate UINT‐16 34A6 R/W R/W, ‐, R N R13479 Serial 5 Data Bits UINT‐16 34A7 R/W R/W, ‐, R N R13480 Serial 5 Stop Bits UINT‐16 34A8 R/W R/W, ‐, R N R13481 Serial 5 Parity UINT‐16 34A9 R/W R/W, ‐, R N R13482 Serial 5 Xmit Delay UINT‐16 34AA R/W R/W, ‐, R N R

Page172 of 229 1/25/2013

Page 173: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13483 Serial 5 Modbus ID UINT‐16 34AB R/W R/W, ‐, R N R13484 Serial 5 RTU/Ascii UINT‐16 34AC R/W R/W, ‐, R N R13485 Serial 5 Enable CRC Checking UINT‐16 34AD R/W R/W, ‐, R N R13486 Serial 5 Modicon 984 Compatible UINT‐16 34AE R/W R/W, ‐, R N R13487 Reserved13488 Reserved13489 Serial 6 Baud Rate UINT‐16 34B1 R/W R/W, ‐, R N R13490 Serial 6 Data Bits UINT‐16 34B2 R/W R/W, ‐, R N R13491 Serial 6 Stop Bits UINT‐16 34B3 R/W R/W, ‐, R N R13492 Serial 6 Parity UINT‐16 34B4 R/W R/W, ‐, R N R13493 Serial 6 Xmit Delay UINT‐16 34B5 R/W R/W, ‐, R N R13494 Serial 6 Modbus ID UINT‐16 34B6 R/W R/W, ‐, R N R13495 Serial 6 RTU/Ascii UINT‐16 34B7 R/W R/W, ‐, R N R13496 Serial 6 Enable CRC Checking UINT‐16 34B8 R/W R/W, ‐, R N R13497 Serial 6 Modicon 984 Compatible UINT‐16 34B9 R/W R/W, ‐, R N R13498 Reserved13499 Reserved13500 Archive 701 1 Starting Index UINT‐16 34BC R/W R/W, R, R N R13501 Archive 701 1 Number of Points UINT‐16 34BD R/W R/W, R, R N R13502 Archive 701 2 Starting Index UINT‐16 34BE R/W R/W, R, R N R13503 Archive 701 2 Number of Points UINT‐16 34BF R/W R/W, R, R N R13504 Archive 701 3 Starting Index UINT‐16 34C0 R/W R/W, R, R N R13505 Archive 701 3 Number of Points UINT‐16 34C1 R/W R/W, R, R N R13506 Archive 701 4 Starting Index UINT‐16 34C2 R/W R/W, R, R N R13507 Archive 701 4 Number of Points UINT‐16 34C3 R/W R/W, R, R N R13508 Archive 701 5 Starting Index UINT‐16 34C4 R/W R/W, R, R N R13509 Archive 701 5 Number of Points UINT‐16 34C5 R/W R/W, R, R N R13510 Archive 701 6 Starting Index UINT‐16 34C6 R/W R/W, R, R N R13511 Archive 701 6 Number of Points UINT‐16 34C7 R/W R/W, R, R N R13512 Archive 701 7 Starting Index UINT‐16 34C8 R/W R/W, R, R N R13513 Archive 701 7 Number of Points UINT‐16 34C9 R/W R/W, R, R N R13514 Archive 701 8 Starting Index UINT‐16 34CA R/W R/W, R, R N R13515 Archive 701 8 Number of Points UINT‐16 34CB R/W R/W, R, R N R13516 Archive 701 9 Starting Index UINT‐16 34CC R/W R/W, R, R N R13517 Archive 701 9 Number of Points UINT‐16 34CD R/W R/W, R, R N R13518 Archive 701 10 Starting Index UINT‐16 34CE R/W R/W, R, R N R13519 Archive 701 10 Number of Points UINT‐16 34CF R/W R/W, R, R N R13520 Archive 701 11 Starting Index UINT‐16 34D0 R/W R/W, R, R N R

Page173 of 229 1/25/2013

Page 174: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13521 Archive 701 11 Number of Points UINT‐16 34D1 R/W R/W, R, R N R13522 Archive 701 12 Starting Index UINT‐16 34D2 R/W R/W, R, R N R13523 Archive 701 12 Number of Points UINT‐16 34D3 R/W R/W, R, R N R13524 Archive 701 13 Starting Index UINT‐16 34D4 R/W R/W, R, R N R13525 Archive 701 13 Number of Points UINT‐16 34D5 R/W R/W, R, R N R13526 Archive 701 14 Starting Index UINT‐16 34D6 R/W R/W, R, R N R13527 Archive 701 14 Number of Points UINT‐16 34D7 R/W R/W, R, R N R13528 Archive 701 15 Starting Index UINT‐16 34D8 R/W R/W, R, R N R13529 Archive 701 15 Number of Points UINT‐16 34D9 R/W R/W, R, R N R13530 Archive 701 16 Starting Index UINT‐16 34DA R/W R/W, R, R N R13531 Archive 701 16 Number of Points UINT‐16 34DB R/W R/W, R, R N R13532 Product 1 Use API 11.1 CTL*CPL (0=No, 

1=Yes)UINT‐16 34DC R/W  R/W, R, R Y R

13533 Product 2 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34DD R/W  R/W, R, R Y R

13534 Product 3 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34DE R/W  R/W, R, R Y R

13535 Product 4 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34DF R/W  R/W, R, R Y R

13536 Product 5 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34E0 R/W  R/W, R, R Y R

13537 Product 6 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34E1 R/W  R/W, R, R Y R

13538 Product 7 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34E2 R/W  R/W, R, R Y R

13539 Product 8 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 34E3 R/W  R/W, R, R Y R

13540 Archive 702 1 Starting Index UINT‐16 34E4 R/W R/W, R, R N R13541 Archive 702 1 Number of Points UINT‐16 34E5 R/W R/W, R, R N R13542 Archive 702 2 Starting Index UINT‐16 34E6 R/W R/W, R, R N R

Page174 of 229 1/25/2013

Page 175: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13543 Archive 702 2 Number of Points UINT‐16 34E7 R/W R/W, R, R N R13544 Archive 702 3 Starting Index UINT‐16 34E8 R/W R/W, R, R N R13545 Archive 702 3 Number of Points UINT‐16 34E9 R/W R/W, R, R N R13546 Archive 702 4 Starting Index UINT‐16 34EA R/W R/W, R, R N R13547 Archive 702 4 Number of Points UINT‐16 34EB R/W R/W, R, R N R13548 Archive 702 5 Starting Index UINT‐16 34EC R/W R/W, R, R N R13549 Archive 702 5 Number of Points UINT‐16 34ED R/W R/W, R, R N R13550 Archive 702 6 Starting Index UINT‐16 34EE R/W R/W, R, R N R13551 Archive 702 6 Number of Points UINT‐16 34EF R/W R/W, R, R N R13552 Archive 702 7 Starting Index UINT‐16 34F0 R/W R/W, R, R N R13553 Archive 702 7 Number of Points UINT‐16 34F1 R/W R/W, R, R N R13554 Archive 702 8 Starting Index UINT‐16 34F2 R/W R/W, R, R N R13555 Archive 702 8 Number of Points UINT‐16 34F3 R/W R/W, R, R N R13556 Archive 702 9 Starting Index UINT‐16 34F4 R/W R/W, R, R N R13557 Archive 702 9 Number of Points UINT‐16 34F5 R/W R/W, R, R N R13558 Archive 702 10 Starting Index UINT‐16 34F6 R/W R/W, R, R N R13559 Archive 702 10 Number of Points UINT‐16 34F7 R/W R/W, R, R N R13560 Archive 702 11 Starting Index UINT‐16 34F8 R/W R/W, R, R N R13561 Archive 702 11 Number of Points UINT‐16 34F9 R/W R/W, R, R N R13562 Archive 702 12 Starting Index UINT‐16 34FA R/W R/W, R, R N R13563 Archive 702 12 Number of Points UINT‐16 34FB R/W R/W, R, R N R13564 Archive 702 13 Starting Index UINT‐16 34FC R/W R/W, R, R N R13565 Archive 702 13 Number of Points UINT‐16 34FD R/W R/W, R, R N R13566 Archive 702 14 Starting Index UINT‐16 34FE R/W R/W, R, R N R13567 Archive 702 14 Number of Points UINT‐16 34FF R/W R/W, R, R N R13568 Archive 702 15 Starting Index UINT‐16 3500 R/W R/W, R, R N R13569 Archive 702 15 Number of Points UINT‐16 3501 R/W R/W, R, R N R13570 Archive 702 16 Starting Index UINT‐16 3502 R/W R/W, R, R N R13571 Archive 702 16 Number of Points UINT‐16 3503 R/W R/W, R, R N R13572 Product 9 Use API 11.1 CTL*CPL (0=No, 

1=Yes)UINT‐16 3504 R/W  R/W, R, R Y R

13573 Product 10 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 3505 R/W  R/W, R, R Y R

13574 Product 11 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 3506 R/W  R/W, R, R Y R

Page175 of 229 1/25/2013

Page 176: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13575 Product 12 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 3507 R/W  R/W, R, R Y R

13576 Product 13 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 3508 R/W  R/W, R, R Y R

13577 Product 14 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 3509 R/W  R/W, R, R Y R

13578 Product 15 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 350A R/W  R/W, R, R Y R

13579 Product 16 Use API 11.1 CTL*CPL (0=No, 1=Yes)

UINT‐16 350B R/W  R/W, R, R Y R

13580 Archive 703 1 Starting Index UINT‐16 350C R/W R/W, R, R N R13581 Archive 703 1 Number of Points UINT‐16 350D R/W R/W, R, R N R13582 Archive 703 2 Starting Index UINT‐16 350E R/W R/W, R, R N R13583 Archive 703 2 Number of Points UINT‐16 350F R/W R/W, R, R N R13584 Archive 703 3 Starting Index UINT‐16 3510 R/W R/W, R, R N R13585 Archive 703 3 Number of Points UINT‐16 3511 R/W R/W, R, R N R13586 Archive 703 4 Starting Index UINT‐16 3512 R/W R/W, R, R N R13587 Archive 703 4 Number of Points UINT‐16 3513 R/W R/W, R, R N R13588 Archive 703 5 Starting Index UINT‐16 3514 R/W R/W, R, R N R13589 Archive 703 5 Number of Points UINT‐16 3515 R/W R/W, R, R N R13590 Archive 703 6 Starting Index UINT‐16 3516 R/W R/W, R, R N R13591 Archive 703 6 Number of Points UINT‐16 3517 R/W R/W, R, R N R13592 Archive 703 7 Starting Index UINT‐16 3518 R/W R/W, R, R N R13593 Archive 703 7 Number of Points UINT‐16 3519 R/W R/W, R, R N R13594 Archive 703 8 Starting Index UINT‐16 351A R/W R/W, R, R N R13595 Archive 703 8 Number of Points UINT‐16 351B R/W R/W, R, R N R13596 Archive 703 9 Starting Index UINT‐16 351C R/W R/W, R, R N R13597 Archive 703 9 Number of Points UINT‐16 351D R/W R/W, R, R N R13598 Archive 703 10 Starting Index UINT‐16 351E R/W R/W, R, R N R13599 Archive 703 10 Number of Points UINT‐16 351F R/W R/W, R, R N R13600 Archive 703 11 Starting Index UINT‐16 3520 R/W R/W, R, R N R13601 Archive 703 11 Number of Points UINT‐16 3521 R/W R/W, R, R N R13602 Archive 703 12 Starting Index UINT‐16 3522 R/W R/W, R, R N R

Page176 of 229 1/25/2013

Page 177: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13603 Archive 703 12 Number of Points UINT‐16 3523 R/W R/W, R, R N R13604 Archive 703 13 Starting Index UINT‐16 3524 R/W R/W, R, R N R13605 Archive 703 13 Number of Points UINT‐16 3525 R/W R/W, R, R N R13606 Archive 703 14 Starting Index UINT‐16 3526 R/W R/W, R, R N R13607 Archive 703 14 Number of Points UINT‐16 3527 R/W R/W, R, R N R13608 Archive 703 15 Starting Index UINT‐16 3528 R/W R/W, R, R N R13609 Archive 703 15 Number of Points UINT‐16 3529 R/W R/W, R, R N R13610 Archive 703 16 Starting Index UINT‐16 352A R/W R/W, R, R N R13611 Archive 703 16 Number of Points UINT‐16 352B R/W R/W, R, R N R13620 Archive 704 1 Starting Index UINT‐16 3534 R/W R/W, R, R N R13621 Archive 704 1 Number of Points UINT‐16 3535 R/W R/W, R, R N R13622 Archive 704 2 Starting Index UINT‐16 3536 R/W R/W, R, R N R13623 Archive 704 2 Number of Points UINT‐16 3537 R/W R/W, R, R N R13624 Archive 704 3 Starting Index UINT‐16 3538 R/W R/W, R, R N R13625 Archive 704 3 Number of Points UINT‐16 3539 R/W R/W, R, R N R13626 Archive 704 4 Starting Index UINT‐16 353A R/W R/W, R, R N R13627 Archive 704 4 Number of Points UINT‐16 353B R/W R/W, R, R N R13628 Archive 704 5 Starting Index UINT‐16 353C R/W R/W, R, R N R13629 Archive 704 5 Number of Points UINT‐16 353D R/W R/W, R, R N R13630 Archive 704 6 Starting Index UINT‐16 353E R/W R/W, R, R N R13631 Archive 704 6 Number of Points UINT‐16 353F R/W R/W, R, R N R13632 Archive 704 7 Starting Index UINT‐16 3540 R/W R/W, R, R N R13633 Archive 704 7 Number of Points UINT‐16 3541 R/W R/W, R, R N R13634 Archive 704 8 Starting Index UINT‐16 3542 R/W R/W, R, R N R13635 Archive 704 8 Number of Points UINT‐16 3543 R/W R/W, R, R N R13636 Archive 704 9 Starting Index UINT‐16 3544 R/W R/W, R, R N R13637 Archive 704 9 Number of Points UINT‐16 3545 R/W R/W, R, R N R13638 Archive 704 10 Starting Index UINT‐16 3546 R/W R/W, R, R N R13639 Archive 704 10 Number of Points UINT‐16 3547 R/W R/W, R, R N R13640 Archive 704 11 Starting Index UINT‐16 3548 R/W R/W, R, R N R13641 Archive 704 11 Number of Points UINT‐16 3549 R/W R/W, R, R N R13642 Archive 704 12 Starting Index UINT‐16 354A R/W R/W, R, R N R13643 Archive 704 12 Number of Points UINT‐16 354B R/W R/W, R, R N R13644 Archive 704 13 Starting Index UINT‐16 354C R/W R/W, R, R N R13645 Archive 704 13 Number of Points UINT‐16 354D R/W R/W, R, R N R13646 Archive 704 14 Starting Index UINT‐16 354E R/W R/W, R, R N R13647 Archive 704 14 Number of Points UINT‐16 354F R/W R/W, R, R N R13648 Archive 704 15 Starting Index UINT‐16 3550 R/W R/W, R, R N R

Page177 of 229 1/25/2013

Page 178: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13649 Archive 704 15 Number of Points UINT‐16 3551 R/W R/W, R, R N R13650 Archive 704 16 Starting Index UINT‐16 3552 R/W R/W, R, R N R13651 Archive 704 16 Number of Points UINT‐16 3553 R/W R/W, R, R N R13652 Meter 1 Batch Sequence 1 Product 

Gravity AdjustUINT‐16 3554 R 0=No Gravity Adjustment

1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

  R, R, R Y R

13653 Meter 1 Batch Sequence 2 Product Gravity Adjust

UINT‐16 3555 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13654 Meter 1 Batch Sequence 3 Product Gravity Adjust

UINT‐16 3556 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13655 Meter 1 Batch Sequence 4 Product Gravity Adjust

UINT‐16 3557 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13656 Meter 1 Batch Sequence 5 Product Gravity Adjust

UINT‐16 3558 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13657 Meter 1 Batch Sequence 6 Product Gravity Adjust

UINT‐16 3559 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13658 Meter 2 Batch Seq 1/Common Batch Stack Seq 7 Gravity Adjust

UINT‐16 355A R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13659 Meter 2 Batch Seq 2/Common Batch Stack Seq 8 Gravity Adjust

UINT‐16 355B R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13660 Archive 705 1 Starting Index UINT‐16 355C R/W R/W, R, R N R13661 Archive 705 1 Number of Points UINT‐16 355D R/W R/W, R, R N R13662 Archive 705 2 Starting Index UINT‐16 355E R/W R/W, R, R N R

Page178 of 229 1/25/2013

Page 179: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13663 Archive 705 2 Number of Points UINT‐16 355F R/W R/W, R, R N R13664 Archive 705 3 Starting Index UINT‐16 3560 R/W R/W, R, R N R13665 Archive 705 3 Number of Points UINT‐16 3561 R/W R/W, R, R N R13666 Archive 705 4 Starting Index UINT‐16 3562 R/W R/W, R, R N R13667 Archive 705 4 Number of Points UINT‐16 3563 R/W R/W, R, R N R13668 Archive 705 5 Starting Index UINT‐16 3564 R/W R/W, R, R N R13669 Archive 705 5 Number of Points UINT‐16 3565 R/W R/W, R, R N R13670 Archive 705 6 Starting Index UINT‐16 3566 R/W R/W, R, R N R13671 Archive 705 6 Number of Points UINT‐16 3567 R/W R/W, R, R N R13672 Archive 705 7 Starting Index UINT‐16 3568 R/W R/W, R, R N R13673 Archive 705 7 Number of Points UINT‐16 3569 R/W R/W, R, R N R13674 Archive 705 8 Starting Index UINT‐16 356A R/W R/W, R, R N R13675 Archive 705 8 Number of Points UINT‐16 356B R/W R/W, R, R N R13676 Archive 705 9 Starting Index UINT‐16 356C R/W R/W, R, R N R13677 Archive 705 9 Number of Points UINT‐16 356D R/W R/W, R, R N R13678 Archive 705 10 Starting Index UINT‐16 356E R/W R/W, R, R N R13679 Archive 705 10 Number of Points UINT‐16 356F R/W R/W, R, R N R13680 Archive 705 11 Starting Index UINT‐16 3570 R/W R/W, R, R N R13681 Archive 705 11 Number of Points UINT‐16 3571 R/W R/W, R, R N R13682 Archive 705 12 Starting Index UINT‐16 3572 R/W R/W, R, R N R13683 Archive 705 12 Number of Points UINT‐16 3573 R/W R/W, R, R N R13684 Archive 705 13 Starting Index UINT‐16 3574 R/W R/W, R, R N R13685 Archive 705 13 Number of Points UINT‐16 3575 R/W R/W, R, R N R13686 Archive 705 14 Starting Index UINT‐16 3576 R/W R/W, R, R N R13687 Archive 705 14 Number of Points UINT‐16 3577 R/W R/W, R, R N R13688 Archive 705 15 Starting Index UINT‐16 3578 R/W R/W, R, R N R13689 Archive 705 15 Number of Points UINT‐16 3579 R/W R/W, R, R N R13690 Archive 705 16 Starting Index UINT‐16 357A R/W R/W, R, R N R13691 Archive 705 16 Number of Points UINT‐16 357B R/W R/W, R, R N R13692 Meter 2 Batch Seq 3/Common Batch 

Stack Seq 9 Gravity AdjustUINT‐16 357C R/W 0=No Gravity Adjustment

1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13693 Meter 2 Batch Seq 4/Common Batch Stack Seq 10 Gravity Adjust

UINT‐16 357D R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

Page179 of 229 1/25/2013

Page 180: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13694 Meter 2 Batch Seq 5/Common Batch Stack Seq 11 Gravity Adjust

UINT‐16 357E R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13695 Meter 2 Batch Seq 6/Common Batch Stack Seq 12 Gravity Adjust

UINT‐16 357F R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13696 Meter 3 Batch Seq 1/Common Batch Stack Seq 13 Gravity Adjust

UINT‐16 3580 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13697 Meter 3 Batch Seq 2/Common Batch Stack Seq 14 Gravity Adjust

UINT‐16 3581 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13698 Meter 3 Batch Seq 3/Common Batch Stack Seq 15 Gravity Adjust

UINT‐16 3582 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13699 Meter 3 Batch Seq 4/Common Batch Stack Seq 16 Gravity Adjust

UINT‐16 3583 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13700 Archive 706 1 Starting Index UINT‐16 3584 R/W R/W, R, R N R13701 Archive 706 1 Number of Points UINT‐16 3585 R/W R/W, R, R N R13702 Archive 706 2 Starting Index UINT‐16 3586 R/W R/W, R, R N R13703 Archive 706 2 Number of Points UINT‐16 3587 R/W R/W, R, R N R13704 Archive 706 3 Starting Index UINT‐16 3588 R/W R/W, R, R N R13705 Archive 706 3 Number of Points UINT‐16 3589 R/W R/W, R, R N R13706 Archive 706 4 Starting Index UINT‐16 358A R/W R/W, R, R N R13707 Archive 706 4 Number of Points UINT‐16 358B R/W R/W, R, R N R13708 Archive 706 5 Starting Index UINT‐16 358C R/W R/W, R, R N R13709 Archive 706 5 Number of Points UINT‐16 358D R/W R/W, R, R N R13710 Archive 706 6 Starting Index UINT‐16 358E R/W R/W, R, R N R13711 Archive 706 6 Number of Points UINT‐16 358F R/W R/W, R, R N R13712 Archive 706 7 Starting Index UINT‐16 3590 R/W R/W, R, R N R13713 Archive 706 7 Number of Points UINT‐16 3591 R/W R/W, R, R N R

Page180 of 229 1/25/2013

Page 181: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13714 Archive 706 8 Starting Index UINT‐16 3592 R/W R/W, R, R N R13715 Archive 706 8 Number of Points UINT‐16 3593 R/W R/W, R, R N R13716 Archive 706 9 Starting Index UINT‐16 3594 R/W R/W, R, R N R13717 Archive 706 9 Number of Points UINT‐16 3595 R/W R/W, R, R N R13718 Archive 706 10 Starting Index UINT‐16 3596 R/W R/W, R, R N R13719 Archive 706 10 Number of Points UINT‐16 3597 R/W R/W, R, R N R13720 Archive 706 11 Starting Index UINT‐16 3598 R/W R/W, R, R N R13721 Archive 706 11 Number of Points UINT‐16 3599 R/W R/W, R, R N R13722 Archive 706 12 Starting Index UINT‐16 359A R/W R/W, R, R N R13723 Archive 706 12 Number of Points UINT‐16 359B R/W R/W, R, R N R13724 Archive 706 13 Starting Index UINT‐16 359C R/W R/W, R, R N R13725 Archive 706 13 Number of Points UINT‐16 359D R/W R/W, R, R N R13726 Archive 706 14 Starting Index UINT‐16 359E R/W R/W, R, R N R13727 Archive 706 14 Number of Points UINT‐16 359F R/W R/W, R, R N R13728 Archive 706 15 Starting Index UINT‐16 35A0 R/W R/W, R, R N R13729 Archive 706 15 Number of Points UINT‐16 35A1 R/W R/W, R, R N R13730 Archive 706 16 Starting Index UINT‐16 35A2 R/W R/W, R, R N R13731 Archive 706 16 Number of Points UINT‐16 35A3 R/W R/W, R, R N R13732 Meter 3 Batch Seq 5/Common Batch 

Stack Seq 17 Gravity AdjustUINT‐16 35A4 R/W 0=No Gravity Adjustment

1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13733 Meter 3 Batch Seq 6/Common Batch Stack Seq 18 Gravity Adjust

UINT‐16 35A5 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13734 Meter 4 Batch Seq 1/Common Batch Stack Seq 19 Gravity Adjust

UINT‐16 35A6 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13735 Meter 4 Batch Seq 2/Common Batch Stack Seq 20 Gravity Adjust

UINT‐16 35A7 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13736 Meter 4 Batch Seq 3/Common Batch Stack Seq 21 Gravity Adjust

UINT‐16 35A8 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

Page181 of 229 1/25/2013

Page 182: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13737 Meter 4 Batch Seq 4/Common Batch Stack Seq 22 Gravity Adjust

UINT‐16 35A9 R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13738 Meter 4 Batch Seq 5/Common Batch Stack Seq 23 Gravity Adjust

UINT‐16 35AA R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13739 Meter 4 Batch Seq 6/Common Batch Stack Seq 24 Gravity Adjust

UINT‐16 35AB R/W 0=No Gravity Adjustment1=Adjust SG at batch stack shift.2=Adjust API at batch stack shift.

 R/W, R, R Y R

13740 Archive 707 1 Starting Index UINT‐16 35AC R/W R/W, R, R N R13741 Archive 707 1 Number of Points UINT‐16 35AD R/W R/W, R, R N R13742 Archive 707 2 Starting Index UINT‐16 35AE R/W R/W, R, R N R13743 Archive 707 2 Number of Points UINT‐16 35AF R/W R/W, R, R N R13744 Archive 707 3 Starting Index UINT‐16 35B0 R/W R/W, R, R N R13728 Archive 707 3 Number of Points UINT‐16 35A0 R/W R/W, R, R N R13746 Archive 707 4 Starting Index UINT‐16 35B2 R/W R/W, R, R N R13747 Archive 707 4 Number of Points UINT‐16 35B3 R/W R/W, R, R N R13748 Archive 707 5 Starting Index UINT‐16 35B4 R/W R/W, R, R N R13749 Archive 707 5 Number of Points UINT‐16 35B5 R/W R/W, R, R N R13750 Archive 707 6 Starting Index UINT‐16 35B6 R/W R/W, R, R N R13745 Archive 707 6 Number of Points UINT‐16 35B1 R/W R/W, R, R N R13752 Archive 707 7 Starting Index UINT‐16 35B8 R/W R/W, R, R N R13753 Archive 707 7 Number of Points UINT‐16 35B9 R/W R/W, R, R N R13754 Archive 707 8 Starting Index UINT‐16 35BA R/W R/W, R, R N R13755 Archive 707 8 Number of Points UINT‐16 35BB R/W R/W, R, R N R13756 Archive 707 9 Starting Index UINT‐16 35BC R/W R/W, R, R N R13757 Archive 707 9 Number of Points UINT‐16 35BD R/W R/W, R, R N R13758 Archive 707 10 Starting Index UINT‐16 35BE R/W R/W, R, R N R13759 Archive 707 10 Number of Points UINT‐16 35BF R/W R/W, R, R N R13760 Archive 707 11 Starting Index UINT‐16 35C0 R/W R/W, R, R N R13761 Archive 707 11 Number of Points UINT‐16 35C1 R/W R/W, R, R N R13762 Archive 707 12 Starting Index UINT‐16 35C2 R/W R/W, R, R N R13763 Archive 707 12 Number of Points UINT‐16 35C3 R/W R/W, R, R N R13764 Archive 707 13 Starting Index UINT‐16 35C4 R/W R/W, R, R N R13765 Archive 707 13 Number of Points UINT‐16 35C5 R/W R/W, R, R N R

Page182 of 229 1/25/2013

Page 183: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13766 Archive 707 14 Starting Index UINT‐16 35C6 R/W R/W, R, R N R13767 Archive 707 14 Number of Points UINT‐16 35C7 R/W R/W, R, R N R13768 Archive 707 15 Starting Index UINT‐16 35C8 R/W R/W, R, R N R13769 Archive 707 15 Number of Points UINT‐16 35C9 R/W R/W, R, R N R13770 Archive 707 16 Starting Index UINT‐16 35CA R/W R/W, R, R N R13771 Archive 707 16 Number of Points UINT‐16 35CB R/W R/W, R, R N R13777 ‐ 13779 Reserved13780 Archive 708 1 Starting Index UINT‐16 35D4 R/W R/W, R, R N R13781 Archive 708 1 Number of Points UINT‐16 35D5 R/W R/W, R, R N R13782 Archive 708 2 Starting Index UINT‐16 35D6 R/W R/W, R, R N R13783 Archive 708 2 Number of Points UINT‐16 35D7 R/W R/W, R, R N R13784 Archive 708 3 Starting Index UINT‐16 35D8 R/W R/W, R, R N R13785 Archive 708 3 Number of Points UINT‐16 35D9 R/W R/W, R, R N R13786 Archive 708 4 Starting Index UINT‐16 35DA R/W R/W, R, R N R13787 Archive 708 4 Number of Points UINT‐16 35DB R/W R/W, R, R N R13788 Archive 708 5 Starting Index UINT‐16 35DC R/W R/W, R, R N R13789 Archive 708 5 Number of Points UINT‐16 35DD R/W R/W, R, R N R13790 Archive 708 6 Starting Index UINT‐16 35DE R/W R/W, R, R N R13791 Archive 708 6 Number of Points UINT‐16 35DF R/W R/W, R, R N R13792 Archive 708 7 Starting Index UINT‐16 35E0 R/W R/W, R, R N R13793 Archive 708 7 Number of Points UINT‐16 35E1 R/W R/W, R, R N R13794 Archive 708 8 Starting Index UINT‐16 35E2 R/W R/W, R, R N R13795 Archive 708 8 Number of Points UINT‐16 35E3 R/W R/W, R, R N R13796 Archive 708 9 Starting Index UINT‐16 35E4 R/W R/W, R, R N R13797 Archive 708 9 Number of Points UINT‐16 35E5 R/W R/W, R, R N R13798 Archive 708 10 Starting Index UINT‐16 35E6 R/W R/W, R, R N R13799 Archive 708 10 Number of Points UINT‐16 35E7 R/W R/W, R, R N R13800 Archive 708 11 Starting Index UINT‐16 35E8 R/W R/W, R, R N R13801 Archive 708 11 Number of Points UINT‐16 35E9 R/W R/W, R, R N R13802 Archive 708 12 Starting Index UINT‐16 35EA R/W R/W, R, R N R13803 Archive 708 12 Number of Points UINT‐16 35EB R/W R/W, R, R N R13804 Archive 708 13 Starting Index UINT‐16 35EC R/W R/W, R, R N R13805 Archive 708 13 Number of Points UINT‐16 35ED R/W R/W, R, R N R13806 Archive 708 14 Starting Index UINT‐16 35EE R/W R/W, R, R N R13807 Archive 708 14 Number of Points UINT‐16 35EF R/W R/W, R, R N R13808 Archive 708 15 Starting Index UINT‐16 35F0 R/W R/W, R, R N R13809 Archive 708 15 Number of Points UINT‐16 35F1 R/W R/W, R, R N R13810 Archive 708 16 Starting Index UINT‐16 35F2 R/W R/W, R, R N R

Page183 of 229 1/25/2013

Page 184: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13811 Archive 708 16 Number of Points UINT‐16 35F3 R/W R/W, R, R N R13812 ‐ 13819 Reserved13820 Archive 709 1 Starting Index UINT‐16 35FC R/W R/W, R, R N R13821 Archive 709 1 Number of Points UINT‐16 35FD R/W R/W, R, R N R13822 Archive 709 2 Starting Index UINT‐16 35FE R/W R/W, R, R N R13823 Archive 709 2 Number of Points UINT‐16 35FF R/W R/W, R, R N R13824 Archive 709 3 Starting Index UINT‐16 3600 R/W R/W, R, R N R13825 Archive 709 3 Number of Points UINT‐16 3601 R/W R/W, R, R N R13826 Archive 709 4 Starting Index UINT‐16 3602 R/W R/W, R, R N R13827 Archive 709 4 Number of Points UINT‐16 3603 R/W R/W, R, R N R13828 Archive 709 5 Starting Index UINT‐16 3604 R/W R/W, R, R N R13829 Archive 709 5 Number of Points UINT‐16 3605 R/W R/W, R, R N R13830 Archive 709 6 Starting Index UINT‐16 3606 R/W R/W, R, R N R13831 Archive 709 6 Number of Points UINT‐16 3607 R/W R/W, R, R N R13832 Archive 709 7 Starting Index UINT‐16 3608 R/W R/W, R, R N R13833 Archive 709 7 Number of Points UINT‐16 3609 R/W R/W, R, R N R13834 Archive 709 8 Starting Index UINT‐16 360A R/W R/W, R, R N R13835 Archive 709 8 Number of Points UINT‐16 360B R/W R/W, R, R N R13836 Archive 709 9 Starting Index UINT‐16 360C R/W R/W, R, R N R13837 Archive 709 9 Number of Points UINT‐16 360D R/W R/W, R, R N R13838 Archive 709 10 Starting Index UINT‐16 360E R/W R/W, R, R N R13839 Archive 709 10 Number of Points UINT‐16 360F R/W R/W, R, R N R13840 Archive 709 11 Starting Index UINT‐16 3610 R/W R/W, R, R N R13841 Archive 709 11 Number of Points UINT‐16 3611 R/W R/W, R, R N R13842 Archive 709 12 Starting Index UINT‐16 3612 R/W R/W, R, R N R13843 Archive 709 12 Number of Points UINT‐16 3613 R/W R/W, R, R N R13844 Archive 709 13 Starting Index UINT‐16 3614 R/W R/W, R, R N R13845 Archive 709 13 Number of Points UINT‐16 3615 R/W R/W, R, R N R13846 Archive 709 14 Starting Index UINT‐16 3616 R/W R/W, R, R N R13847 Archive 709 14 Number of Points UINT‐16 3617 R/W R/W, R, R N R13848 Archive 709 15 Starting Index UINT‐16 3618 R/W R/W, R, R N R13849 Archive 709 15 Number of Points UINT‐16 3619 R/W R/W, R, R N R13850 Archive 709 16 Starting Index UINT‐16 361A R/W R/W, R, R N R13851 Archive 709 16 Number of Points UINT‐16 361B R/W R/W, R, R N R13860 Archive 710 1 Starting Index UINT‐16 3624 R/W R/W, R, R N R13861 Archive 710 1 Number of Points UINT‐16 3625 R/W R/W, R, R N R13862 Archive 710 2 Starting Index UINT‐16 3626 R/W R/W, R, R N R13863 Archive 710 2 Number of Points UINT‐16 3627 R/W R/W, R, R N R

Page184 of 229 1/25/2013

Page 185: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13864 Archive 710 3 Starting Index UINT‐16 3628 R/W R/W, R, R N R13865 Archive 710 3 Number of Points UINT‐16 3629 R/W R/W, R, R N R13866 Archive 710 4 Starting Index UINT‐16 362A R/W R/W, R, R N R13867 Archive 710 4 Number of Points UINT‐16 362B R/W R/W, R, R N R13868 Archive 710 5 Starting Index UINT‐16 362C R/W R/W, R, R N R13869 Archive 710 5 Number of Points UINT‐16 362D R/W R/W, R, R N R13870 Archive 710 6 Starting Index UINT‐16 362E R/W R/W, R, R N R13871 Archive 710 6 Number of Points UINT‐16 362F R/W R/W, R, R N R13872 Archive 710 7 Starting Index UINT‐16 3630 R/W R/W, R, R N R13873 Archive 710 7 Number of Points UINT‐16 3631 R/W R/W, R, R N R13874 Archive 710 8 Starting Index UINT‐16 3632 R/W R/W, R, R N R13875 Archive 710 8 Number of Points UINT‐16 3633 R/W R/W, R, R N R13876 Archive 710 9 Starting Index UINT‐16 3634 R/W R/W, R, R N R13877 Archive 710 9 Number of Points UINT‐16 3635 R/W R/W, R, R N R13878 Archive 710 10 Starting Index UINT‐16 3636 R/W R/W, R, R N R13879 Archive 710 10 Number of Points UINT‐16 3637 R/W R/W, R, R N R13880 Archive 710 11 Starting Index UINT‐16 3638 R/W R/W, R, R N R13881 Archive 710 11 Number of Points UINT‐16 3639 R/W R/W, R, R N R13882 Archive 710 12 Starting Index UINT‐16 363A R/W R/W, R, R N R13883 Archive 710 12 Number of Points UINT‐16 363B R/W R/W, R, R N R13884 Archive 710 13 Starting Index UINT‐16 363C R/W R/W, R, R N R13885 Archive 710 13 Number of Points UINT‐16 363D R/W R/W, R, R N R13886 Archive 710 14 Starting Index UINT‐16 363E R/W R/W, R, R N R13887 Archive 710 14 Number of Points UINT‐16 363F R/W R/W, R, R N R13888 Archive 710 15 Starting Index UINT‐16 3640 R/W R/W, R, R N R13889 Archive 710 15 Number of Points UINT‐16 3641 R/W R/W, R, R N R13890 Archive 710 16 Starting Index UINT‐16 3642 R/W R/W, R, R N R13891 Archive 710 16 Number of Points UINT‐16 3643 R/W R/W, R, R N R13900 Archive 701 Trigger Boolean UINT‐16 364C R/W R/W, R, R N R13901 Archive 702 Trigger Boolean UINT‐16 364D R/W R/W, R, R N R13902 Archive 703 Trigger Boolean UINT‐16 364E R/W R/W, R, R N R13903 Archive 704 Trigger Boolean UINT‐16 364F R/W R/W, R, R N R13904 Archive 705 Trigger Boolean UINT‐16 3650 R/W R/W, R, R N R13905 Archive 706 Trigger Boolean UINT‐16 3651 R/W R/W, R, R N R13906 Archive 707 Trigger Boolean UINT‐16 3652 R/W R/W, R, R N R13907 Archive 708 Trigger Boolean UINT‐16 3653 R/W R/W, R, R N R13908 Archive 709 Trigger Boolean UINT‐16 3654 R/W R/W, R, R N R13909 Archive 710 Trigger Boolean UINT‐16 3655 R/W R/W, R, R N R

Page185 of 229 1/25/2013

Page 186: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

13910 ‐ 13919 Reserved13920 Archive Run (0=No, 1=Yes) UINT‐16 3660 R/W R/W, R, R N R13921 Re‐Configure Archive (0=No, 1=Yes) UINT‐16 3661 R/W R/W, R, R N R13930 ‐ 13961 Archive 711 Starting Index UINT‐16 366A R/W R/W, R, R R13962 ‐ 13993 Archive 712 Starting Index UINT‐16 368A R/W R/W, R, R R13998 ‐ 13999 Reserved

16 character Ascii strings

14001 Boolean Point 25 ASCII‐16 36B1 R/W R/W, ‐, R N R14002 Boolean Point 26 ASCII‐16 36B2 R/W R/W, ‐, R N R14003 Boolean Point 27 ASCII‐16 36B3 R/W R/W, ‐, R N R14004 Boolean Point 28 ASCII‐16 36B4 R/W R/W, ‐, R N R14005 Boolean Point 29 ASCII‐16 36B5 R/W R/W, ‐, R N R14006 Boolean Point 30 ASCII‐16 36B6 R/W R/W, ‐, R N R14007 Boolean Point 31 ASCII‐16 36B7 R/W R/W, ‐, R N R14008 Boolean Point 32 ASCII‐16 36B8 R/W R/W, ‐, R N R14009 Boolean Point 33 ASCII‐16 36B9 R/W R/W, ‐, R N R14010 Boolean Point 34 ASCII‐16 36BA R/W R/W, ‐, R N R14011 Boolean Point 35 ASCII‐16 36BB R/W R/W, ‐, R N R14012 Boolean Point 36 ASCII‐16 36BC R/W R/W, ‐, R N R14013 Boolean Point 37 ASCII‐16 36BD R/W R/W, ‐, R N R14014 Boolean Point 38 ASCII‐16 36BE R/W R/W, ‐, R N R14015 Boolean Point 39 ASCII‐16 36BF R/W R/W, ‐, R N R14016 Boolean Point 40 ASCII‐16 36C0 R/W R/W, ‐, R N R14017 Boolean Point 41 ASCII‐16 36C1 R/W R/W, ‐, R N R14018 Boolean Point 42 ASCII‐16 36C2 R/W R/W, ‐, R N R14019 Boolean Point 43 ASCII‐16 36C3 R/W R/W, ‐, R N R14020 Boolean Point 44 ASCII‐16 36C4 R/W R/W, ‐, R N R14021 Boolean Point 45 ASCII‐16 36C5 R/W R/W, ‐, R N R14022 Boolean Point 46 ASCII‐16 36C6 R/W R/W, ‐, R N R14023 Boolean Point 47 ASCII‐16 36C7 R/W R/W, ‐, R N R14024 Boolean Point 48 ASCII‐16 36C8 R/W R/W, ‐, R N R14025 Boolean Point 49 ASCII‐16 36C9 R/W R/W, ‐, R N R14026 Boolean Point 50 ASCII‐16 36CA R/W R/W, ‐, R N R14027 Boolean Point 51 ASCII‐16 36CB R/W R/W, ‐, R N R14028 Boolean Point 52 ASCII‐16 36CC R/W R/W, ‐, R N R14029 Boolean Point 53 ASCII‐16 36CD R/W R/W, ‐, R N R

Page186 of 229 1/25/2013

Page 187: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

14030 Boolean Point 54 ASCII‐16 36CE R/W R/W, ‐, R N R14031 Boolean Point 55 ASCII‐16 36CF R/W R/W, ‐, R N R14032 Boolean Point 56 ASCII‐16 36D0 R/W R/W, ‐, R N R14033 Boolean Point 57 ASCII‐16 36D1 R/W R/W, ‐, R N R14034 Boolean Point 58 ASCII‐16 36D2 R/W R/W, ‐, R N R14035 Boolean Point 59 ASCII‐16 36D3 R/W R/W, ‐, R N R14036 Boolean Point 60 ASCII‐16 36D4 R/W R/W, ‐, R N R14037 Boolean Point 61 ASCII‐16 36D5 R/W R/W, ‐, R N R14038 Boolean Point 62 ASCII‐16 36D6 R/W R/W, ‐, R N R14039 Boolean Point 63 ASCII‐16 36D7 R/W R/W, ‐, R N R14040 Boolean Point 64 ASCII‐16 36D8 R/W R/W, ‐, R N R14041 Boolean Point 65 ASCII‐16 36D9 R/W R/W, ‐, R N R14042 Boolean Point 66 ASCII‐16 36DA R/W R/W, ‐, R N R14043 Boolean Point 67 ASCII‐16 36DB R/W R/W, ‐, R N R14044 Boolean Point 68 ASCII‐16 36DC R/W R/W, ‐, R N R14045 Boolean Point 69 ASCII‐16 36DD R/W R/W, ‐, R N R14046 Boolean Point 70 ASCII‐16 36DE R/W R/W, ‐, R N R14047 Boolean Point 71 ASCII‐16 36DF R/W R/W, ‐, R N R14048 Boolean Point 72 ASCII‐16 36E0 R/W R/W, ‐, R N R14049 Omnicom Download Serial  & File Name ASCII‐16 36E1 R/W R/W, ‐, R R14050 Omnicom Download PC ID ASCII‐16 36E2 R/W R/W, ‐, R R14051 Programmable Variable 25 ASCII‐16 36E3 R/W R/W, ‐, R N R14052 Programmable Variable 26 ASCII‐16 36E4 R/W R/W, ‐, R N R14053 Programmable Variable 27 ASCII‐16 36E5 R/W R/W, ‐, R N R14054 Programmable Variable 28 ASCII‐16 36E6 R/W R/W, ‐, R N R14055 Programmable Variable 29 ASCII‐16 36E7 R/W R/W, ‐, R N R14056 Programmable Variable 30 ASCII‐16 36E8 R/W R/W, ‐, R N R14057 Programmable Variable 31 ASCII‐16 36E9 R/W R/W, ‐, R N R14058 Programmable Variable 32 ASCII‐16 36EA R/W R/W, ‐, R N R14059 Programmable Variable 33 ASCII‐16 36EB R/W R/W, ‐, R N R14060 Programmable Variable 34 ASCII‐16 36EC R/W R/W, ‐, R N R14061 Programmable Variable 35 ASCII‐16 36ED R/W R/W, ‐, R N R14062 Programmable Variable 36 ASCII‐16 36EE R/W R/W, ‐, R N R14063 Programmable Variable 37 ASCII‐16 36EF R/W R/W, ‐, R N R14064 Programmable Variable 38 ASCII‐16 36F0 R/W R/W, ‐, R N R14065 Programmable Variable 39 ASCII‐16 36F1 R/W R/W, ‐, R N R14066 Programmable Variable 40 ASCII‐16 36F2 R/W R/W, ‐, R N R14067 Programmable Variable 41 ASCII‐16 36F3 R/W R/W, ‐, R N R

Page187 of 229 1/25/2013

Page 188: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

14068 Programmable Variable 42 ASCII‐16 36F4 R/W R/W, ‐, R N R14069 Programmable Variable 43 ASCII‐16 36F5 R/W R/W, ‐, R N R14070 Programmable Variable 44 ASCII‐16 36F6 R/W R/W, ‐, R N R14071 Programmable Variable 45 ASCII‐16 36F7 R/W R/W, ‐, R N R14072 Programmable Variable 46 ASCII‐16 36F8 R/W R/W, ‐, R N R14073 Programmable Variable 47 ASCII‐16 36F9 R/W R/W, ‐, R N R14074 Programmable Variable 48 ASCII‐16 36FA R/W R/W, ‐, R N R14075 Programmable Variable 49 ASCII‐16 36FB R/W R/W, ‐, R N R14076 Programmable Variable 50 ASCII‐16 36FC R/W R/W, ‐, R N R14077 Programmable Variable 51 ASCII‐16 36FD R/W R/W, ‐, R N R14078 Programmable Variable 52 ASCII‐16 36FE R/W R/W, ‐, R N R14079 Programmable Variable 53 ASCII‐16 36FF R/W R/W, ‐, R N R14080 Programmable Variable 54 ASCII‐16 3700 R/W R/W, ‐, R N R14081 Programmable Variable 55 ASCII‐16 3701 R/W R/W, ‐, R N R14082 Programmable Variable 56 ASCII‐16 3702 R/W R/W, ‐, R N R14083 Programmable Variable 57 ASCII‐16 3703 R/W R/W, ‐, R N R14084 Programmable Variable 58 ASCII‐16 3704 R/W R/W, ‐, R N R14085 Programmable Variable 59 ASCII‐16 3705 R/W R/W, ‐, R N R14086 Programmable Variable 60 ASCII‐16 3706 R/W R/W, ‐, R N R14087 Programmable Variable 61 ASCII‐16 3707 R/W R/W, ‐, R N R14088 Programmable Variable 62 ASCII‐16 3708 R/W R/W, ‐, R N R14089 Programmable Variable 63 ASCII‐16 3709 R/W R/W, ‐, R N R14090 Programmable Variable 64 ASCII‐16 370A R/W R/W, ‐, R N R14091 Programmable Variable 65 ASCII‐16 370B R/W R/W, ‐, R N R14092 Programmable Variable 66 ASCII‐16 370C R/W R/W, ‐, R N R14093 Programmable Variable 67 ASCII‐16 370D R/W R/W, ‐, R N R14094 Programmable Variable 68 ASCII‐16 370E R/W R/W, ‐, R N R14095 Programmable Variable 69 ASCII‐16 370F R/W R/W, ‐, R N R14096 Programmable Variable 70 ASCII‐16 3710 R/W R/W, ‐, R N R14097 Programmable Variable 71 ASCII‐16 3711 R/W R/W, ‐, R N R14098 Programmable Variable 72 ASCII‐16 3712 R/W R/W, ‐, R N R14099 68‐6201 CPU Serial Number ASCII‐16 3713 R   R, R, R R

14100 Station Definition ASCII‐16 3714 R/W R/W, R, R N R14101 Boolean 25 Remarks ASCII‐16 3715 R/W R/W, ‐, R N R14148 Boolean 72 Remarks ASCII‐16 3744 R/W R/W, ‐, R N R14149 Printer Condense Mode String ASCII‐16 3745 R/W R/W, ‐, R N R14150 Printer Uncondense Mode String ASCII‐16 3746 R/W R/W, ‐, R N R

Page188 of 229 1/25/2013

Page 189: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

14151 Programmable Variable 25 Remarks ASCII‐16 3747 R/W R/W, ‐, R N R14198 Programmable Variable 72 Remarks ASCII‐16 3776 R/W R/W, ‐, R N R14199 Reserved

14201 Boolean Point 73 ASCII‐16 3779 R/W R/W, ‐, R N R14202 Boolean Point 74 ASCII‐16 377A R/W R/W, ‐, R N R14203 Boolean Point 75 ASCII‐16 377B R/W R/W, ‐, R N R14204 Boolean Point 76 ASCII‐16 377C R/W R/W, ‐, R N R14205 Boolean Point 77 ASCII‐16 377D R/W R/W, ‐, R N R14206 Boolean Point 78 ASCII‐16 377E R/W R/W, ‐, R N R14207 Boolean Point 79 ASCII‐16 377F R/W R/W, ‐, R N R14208 Boolean Point 80 ASCII‐16 3780 R/W R/W, ‐, R N R14209 Boolean Point 81 ASCII‐16 3781 R/W R/W, ‐, R N R14210 Boolean Point 82 ASCII‐16 3782 R/W R/W, ‐, R N R14211 Boolean Point 83 ASCII‐16 3783 R/W R/W, ‐, R N R14212 Boolean Point 84 ASCII‐16 3784 R/W R/W, ‐, R N R14213 Boolean Point 85 ASCII‐16 3785 R/W R/W, ‐, R N R14214 Boolean Point 86 ASCII‐16 3786 R/W R/W, ‐, R N R14215 Boolean Point 87 ASCII‐16 3787 R/W R/W, ‐, R N R14216 Boolean Point 88 ASCII‐16 3788 R/W R/W, ‐, R N R14217 ‐ 14220 Reserved14221 Programmable Variable 73 ASCII‐16 378D R/W R/W, ‐, R N R14222 Programmable Variable 74 ASCII‐16 378E R/W R/W, ‐, R N R14223 Programmable Variable 75 ASCII‐16 378F R/W R/W, ‐, R N R14224 Programmable Variable 76 ASCII‐16 3790 R/W R/W, ‐, R N R14225 Programmable Variable 77 ASCII‐16 3791 R/W R/W, ‐, R N R14226 Programmable Variable 78 ASCII‐16 3792 R/W R/W, ‐, R N R14227 Programmable Variable 79 ASCII‐16 3793 R/W R/W, ‐, R N R14228 Programmable Variable 80 ASCII‐16 3794 R/W R/W, ‐, R N R14229 Programmable Variable 81 ASCII‐16 3795 R/W R/W, ‐, R N R14230 Programmable Variable 82 ASCII‐16 3796 R/W R/W, ‐, R N R14231 Programmable Variable 83 ASCII‐16 3797 R/W R/W, ‐, R N R14232 Programmable Variable 84 ASCII‐16 3798 R/W R/W, ‐, R N R14233 Programmable Variable 85 ASCII‐16 3799 R/W R/W, ‐, R N R14234 Programmable Variable 86 ASCII‐16 379A R/W R/W, ‐, R N R14235 Programmable Variable 87 ASCII‐16 379B R/W R/W, ‐, R N R14236 Programmable Variable 88 ASCII‐16 379C R/W R/W, ‐, R N R14237 ‐ 14240 Reserved

Page189 of 229 1/25/2013

Page 190: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

14241 Boolean 73 Remarks ASCII‐16 37A1 R/W R/W, ‐, R N R14256 Boolean 88 Remarks ASCII‐16 37B0 R/W R/W, ‐, R N R14257 ‐ 14260 Reserved14261 Programmable Variable 73 Remarks ASCII‐16 37B5 R/W R/W, ‐, R N R14276 Programmable Variable 88 Remarks ASCII‐16 37C4 R/W R/W, ‐, R N R14277 ‐ 14300 Reserved14301 D/A Output 1 Remarks ASCII‐16 37DD R/W R/W, ‐, R N R14302 D/A Output 2 Remarks ASCII‐16 37DE R/W R/W, ‐, R N R14303 D/A Output 3 Remarks ASCII‐16 37DF R/W R/W, ‐, R N R14304 D/A Output 4 Remarks ASCII‐16 37E0 R/W R/W, ‐, R N R14305 D/A Output 5 Remarks ASCII‐16 37E1 R/W R/W, ‐, R N R14306 D/A Output 6 Remarks ASCII‐16 37E2 R/W R/W, ‐, R N R14307 D/A Output 7 Remarks ASCII‐16 37E3 R/W R/W, ‐, R N R14308 D/A Output 8 Remarks ASCII‐16 37E4 R/W R/W, ‐, R N R14309 D/A Output 9 Remarks ASCII‐16 37E5 R/W R/W, ‐, R N R14310 D/A Output 10 Remarks ASCII‐16 37E6 R/W R/W, ‐, R N R14311 D/A Output 11 Remarks ASCII‐16 37E7 R/W R/W, ‐, R N R14312 D/A Output 12 Remarks ASCII‐16 37E8 R/W R/W, ‐, R N R14313 ‐ 14320 Reserved14321 Digital 1 Remarks ASCII‐16 37F1 R/W R/W, ‐, R N R14322 Digital 2 Remarks ASCII‐16 37F2 R/W R/W, ‐, R N R14323 Digital 3 Remarks ASCII‐16 37F3 R/W R/W, ‐, R N R14324 Digital 4 Remarks ASCII‐16 37F4 R/W R/W, ‐, R N R14325 Digital 5 Remarks ASCII‐16 37F5 R/W R/W, ‐, R N R14326 Digital 6 Remarks ASCII‐16 37F6 R/W R/W, ‐, R N R14327 Digital 7 Remarks ASCII‐16 37F7 R/W R/W, ‐, R N R14328 Digital 8 Remarks ASCII‐16 37F8 R/W R/W, ‐, R N R14329 Digital 9 Remarks ASCII‐16 37F9 R/W R/W, ‐, R N R14330 Digital 10 Remarks ASCII‐16 37FA R/W R/W, ‐, R N R14331 Digital 11 Remarks ASCII‐16 37FB R/W R/W, ‐, R N R14332 Digital 12 Remarks ASCII‐16 37FC R/W R/W, ‐, R N R14333 Digital 13 Remarks ASCII‐16 37FD R/W R/W, ‐, R N R14334 Digital 14 Remarks ASCII‐16 37FE R/W R/W, ‐, R N R14335 Digital 15 Remarks ASCII‐16 37FF R/W R/W, ‐, R N R14336 Digital 16 Remarks ASCII‐16 3800 R/W R/W, ‐, R N R14337 Digital 17 Remarks ASCII‐16 3801 R/W R/W, ‐, R N R14338 Digital 18 Remarks ASCII‐16 3802 R/W R/W, ‐, R N R14339 Digital 19 Remarks ASCII‐16 3803 R/W R/W, ‐, R N R

Page190 of 229 1/25/2013

Page 191: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

14340 Digital 20 Remarks ASCII‐16 3804 R/W R/W, ‐, R N R14341 Digital 21 Remarks ASCII‐16 3805 R/W R/W, ‐, R N R14342 Digital 22 Remarks ASCII‐16 3806 R/W R/W, ‐, R N R14343 Digital 23 Remarks ASCII‐16 3807 R/W R/W, ‐, R N R14344 Digital 24 Remarks ASCII‐16 3808 R/W R/W, ‐, R N R14345 ‐ 14359 Reserved14360 PID 1 Primary Variable Remarks ASCII‐16 3818 R/W R/W, ‐, R N R14361 PID 1 Secondary Variable Remarks ASCII‐16 3819 R/W R/W, ‐, R N R14362 PID 2 Primary Variable Remarks ASCII‐16 381A R/W R/W, ‐, R N R14363 PID 2 Secondary Variable Remarks ASCII‐16 381B R/W R/W, ‐, R N R14364 PID 3 Primary Variable Remarks ASCII‐16 381C R/W R/W, ‐, R N R14365 PID 3 Secondary Variable Remarks ASCII‐16 381D R/W R/W, ‐, R N R14366 PID 4 Primary Variable Remarks ASCII‐16 381E R/W R/W, ‐, R N R14367 PID 4 Secondary Variable Remarks ASCII‐16 381F R/W R/W, ‐, R N R14368 ‐ 14379 Reserved14380 Front Panel Counter A Remarks ASCII‐16 382C R/W R/W, ‐, R N R14381 Front Panel Counter B Remarks ASCII‐16 382D R/W R/W, ‐, R N R14382 Front Panel Counter C Remarks ASCII‐16 382E R/W R/W, ‐, R N R14383 Reserved14390 ‐ 14999 Reserved

32 Bit integers

15001 Analog Output 1 Assign UINT‐32 3A99 R/W R/W, ‐, R N R15002 Analog Output 2 Assign UINT‐32 3A9A R/W R/W, ‐, R N R15003 Analog Output 3 Assign UINT‐32 3A9B R/W R/W, ‐, R N R15004 Analog Output 4 Assign UINT‐32 3A9C R/W R/W, ‐, R N R15005 Analog Output 5 Assign UINT‐32 3A9D R/W R/W, ‐, R N R15006 Analog Output 6 Assign UINT‐32 3A9E R/W R/W, ‐, R N R15007 Analog Output 7 Assign UINT‐32 3A9F R/W R/W, ‐, R N R15008 Analog Output 8 Assign UINT‐32 3AA0 R/W R/W, ‐, R N R15009 Analog Output 9 Assign UINT‐32 3AA1 R/W R/W, ‐, R N R15010 Analog Output 10 Assign UINT‐32 3AA2 R/W R/W, ‐, R N R15011 Analog Output 11 Assign UINT‐32 3AA3 R/W R/W, ‐, R N R15012 Analog Output 12 Assign UINT‐32 3AA4 R/W R/W, ‐, R N R15013 Digital Point 1 Assignment UINT‐32 3AA5 R/W R/W, ‐, R N R15014 Delay On  Ticks UINT‐32 3AA6 R/W R/W, ‐, R N R15015 Delay Off Ticks UINT‐32 3AA7 R/W R/W, ‐, R N R

Page191 of 229 1/25/2013

Page 192: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15016 Pulse Width UINT‐32 3AA8 R/W R/W, ‐, R N R15017 Digital Point 2 Assignment UINT‐32 3AA9 R/W R/W, ‐, R N R15018 Delay On  Ticks UINT‐32 3AAA R/W R/W, ‐, R N R15019 Delay Off Ticks UINT‐32 3AAB R/W R/W, ‐, R N R15020 Pulse Width UINT‐32 3AAC R/W R/W, ‐, R N R15021 Digital Point 3 Assignment UINT‐32 3AAD R/W R/W, ‐, R N R15022 Delay On  Ticks UINT‐32 3AAE R/W R/W, ‐, R N R15023 Delay Off Ticks UINT‐32 3AAF R/W R/W, ‐, R N R15024 Pulse Width UINT‐32 3AB0 R/W R/W, ‐, R N R15025 Digital Point 4 Assignment UINT‐32 3AB1 R/W R/W, ‐, R N R15026 Delay On  Ticks UINT‐32 3AB2 R/W R/W, ‐, R N R15027 Delay Off Ticks UINT‐32 3AB3 R/W R/W, ‐, R N R15028 Pulse Width UINT‐32 3AB4 R/W R/W, ‐, R N R15029 Digital Point 5 Assignment UINT‐32 3AB5 R/W R/W, ‐, R N R15030 Delay On  Ticks UINT‐32 3AB6 R/W R/W, ‐, R N R15031 Delay Off Ticks UINT‐32 3AB7 R/W R/W, ‐, R N R15032 Pulse Width UINT‐32 3AB8 R/W R/W, ‐, R N R15033 Digital Point 6 Assignment UINT‐32 3AB9 R/W R/W, ‐, R N R15034 Delay On  Ticks UINT‐32 3ABA R/W R/W, ‐, R N R15035 Delay Off Ticks UINT‐32 3ABB R/W R/W, ‐, R N R15036 Pulse Width UINT‐32 3ABC R/W R/W, ‐, R N R15037 Digital Point 7 Assignment UINT‐32 3ABD R/W R/W, ‐, R N R15038 Delay On  Ticks UINT‐32 3ABE R/W R/W, ‐, R N R15039 Delay Off Ticks UINT‐32 3ABF R/W R/W, ‐, R N R15040 Pulse Width UINT‐32 3AC0 R/W R/W, ‐, R N R15041 Digital Point 8 Assignment UINT‐32 3AC1 R/W R/W, ‐, R N R15042 Delay On  Ticks UINT‐32 3AC2 R/W R/W, ‐, R N R15043 Delay Off Ticks UINT‐32 3AC3 R/W R/W, ‐, R N R15044 Pulse Width UINT‐32 3AC4 R/W R/W, ‐, R N R15045 Digital Point 9 Assignment UINT‐32 3AC5 R/W R/W, ‐, R N R15046 Delay On  Ticks UINT‐32 3AC6 R/W R/W, ‐, R N R15047 Delay Off Ticks UINT‐32 3AC7 R/W R/W, ‐, R N R15048 Pulse Width UINT‐32 3AC8 R/W R/W, ‐, R N R15049 Digital Point 10 Assignment UINT‐32 3AC9 R/W R/W, ‐, R N R15050 Delay On  Ticks UINT‐32 3ACA R/W R/W, ‐, R N R15051 Delay Off Ticks UINT‐32 3ACB R/W R/W, ‐, R N R15052 Pulse Width UINT‐32 3ACC R/W R/W, ‐, R N R15053 Digital Point 11 Assignment UINT‐32 3ACD R/W R/W, ‐, R N R

Page192 of 229 1/25/2013

Page 193: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15054 Delay On  Ticks UINT‐32 3ACE R/W R/W, ‐, R N R15055 Delay Off Ticks UINT‐32 3ACF R/W R/W, ‐, R N R15056 Pulse Width UINT‐32 3AD0 R/W R/W, ‐, R N R15057 Digital Point 12 Assignment UINT‐32 3AD1 R/W R/W, ‐, R N R15058 Delay On  Ticks UINT‐32 3AD2 R/W R/W, ‐, R N R15059 Delay Off Ticks UINT‐32 3AD3 R/W R/W, ‐, R N R15060 Pulse Width UINT‐32 3AD4 R/W R/W, ‐, R N R15061 Digital Point 13 Assignment UINT‐32 3AD5 R/W R/W, ‐, R N R15062 Delay On  Ticks UINT‐32 3AD6 R/W R/W, ‐, R N R15063 Delay Off Ticks UINT‐32 3AD7 R/W R/W, ‐, R N R15064 Pulse Width UINT‐32 3AD8 R/W R/W, ‐, R N R15065 Digital Point 14 Assignment UINT‐32 3AD9 R/W R/W, ‐, R N R15066 Delay On  Ticks UINT‐32 3ADA R/W R/W, ‐, R N R15067 Delay Off Ticks UINT‐32 3ADB R/W R/W, ‐, R N R15068 Pulse Width UINT‐32 3ADC R/W R/W, ‐, R N R15069 Digital Point 15 Assignment UINT‐32 3ADD R/W R/W, ‐, R N R15070 Delay On  Ticks UINT‐32 3ADE R/W R/W, ‐, R N R15071 Delay Off Ticks UINT‐32 3ADF R/W R/W, ‐, R N R15072 Pulse Width UINT‐32 3AE0 R/W R/W, ‐, R N R15073 Digital Point 16 Assignment UINT‐32 3AE1 R/W R/W, ‐, R N R15074 Delay On  Ticks UINT‐32 3AE2 R/W R/W, ‐, R N R15075 Delay Off Ticks UINT‐32 3AE3 R/W R/W, ‐, R N R15076 Pulse Width UINT‐32 3AE4 R/W R/W, ‐, R N R15077 Digital Point 17 Assignment UINT‐32 3AE5 R/W R/W, ‐, R N R15078 Delay On  Ticks UINT‐32 3AE6 R/W R/W, ‐, R N R15079 Delay Off Ticks UINT‐32 3AE7 R/W R/W, ‐, R N R15080 Pulse Width UINT‐32 3AE8 R/W R/W, ‐, R N R15081 Digital Point 18 Assignment UINT‐32 3AE9 R/W R/W, ‐, R N R15082 Delay On  Ticks UINT‐32 3AEA R/W R/W, ‐, R N R15083 Delay Off Ticks UINT‐32 3AEB R/W R/W, ‐, R N R15084 Pulse Width UINT‐32 3AEC R/W R/W, ‐, R N R15085 Digital Point 19 Assignment UINT‐32 3AED R/W R/W, ‐, R N R15086 Delay On  Ticks UINT‐32 3AEE R/W R/W, ‐, R N R15087 Delay Off Ticks UINT‐32 3AEF R/W R/W, ‐, R N R15088 Pulse Width UINT‐32 3AF0 R/W R/W, ‐, R N R15089 Digital Point 20 Assignment UINT‐32 3AF1 R/W R/W, ‐, R N R15090 Delay On  Ticks UINT‐32 3AF2 R/W R/W, ‐, R N R15091 Delay Off Ticks UINT‐32 3AF3 R/W R/W, ‐, R N R

Page193 of 229 1/25/2013

Page 194: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15092 Pulse Width UINT‐32 3AF4 R/W R/W, ‐, R N R15093 Digital Point 21 Assignment UINT‐32 3AF5 R/W R/W, ‐, R N R15094 Delay On  Ticks UINT‐32 3AF6 R/W R/W, ‐, R N R15095 Delay Off Ticks UINT‐32 3AF7 R/W R/W, ‐, R N R15096 Pulse Width UINT‐32 3AF8 R/W R/W, ‐, R N R15097 Digital Point 22 Assignment UINT‐32 3AF9 R/W R/W, ‐, R N R15098 Delay On  Ticks UINT‐32 3AFA R/W R/W, ‐, R N R15099 Delay Off Ticks UINT‐32 3AFB R/W R/W, ‐, R N R15100 Pulse Width UINT‐32 3AFC R/W R/W, ‐, R N R15101 Digital Point 23 Assignment UINT‐32 3AFD R/W R/W, ‐, R N R15102 Delay On  Ticks UINT‐32 3AFE R/W R/W, ‐, R N R15103 Delay Off Ticks UINT‐32 3AFF R/W R/W, ‐, R N R15104 Pulse Width UINT‐32 3B00 R/W R/W, ‐, R N R15105 Digital Point 24 Assignment UINT‐32 3B01 R/W R/W, ‐, R N R15106 Delay On  Ticks UINT‐32 3B02 R/W R/W, ‐, R N R15107 Delay Off Ticks UINT‐32 3B03 R/W R/W, ‐, R N R15108 Pulse Width UINT‐32 3B04 R/W R/W, ‐, R N R15109 Front Panel Counter A Assignment UINT‐32 3B05 R/W R/W, ‐, R N R15110 Front Panel Counter B Assignment UINT‐32 3B06 R/W R/W, ‐, R N R15111 Front Panel Counter C Assignment UINT‐32 3B07 R/W R/W, ‐, R N R15112 Meter 1 comparator Error Counts UINT‐32 3B08 R/W R/W, ‐, R Y R15113 Meter 2 comparator Error Counts UINT‐32 3B09 R/W R/W, ‐, R Y R15114 Meter 3 comparator Error Counts UINT‐32 3B0A R/W R/W, ‐, R Y R15115 Meter 4 comparator Error Counts UINT‐32 3B0B R/W R/W, ‐, R Y R15116 M1  Good Pulses to Reset the comparator 

AlarmUINT‐32 3B0C R/W  R/W, ‐, R Y R

15117 M2  Good Pulses to Reset the comparator Alarm

UINT‐32 3B0D R/W  R/W, ‐, R Y R

15118 M3  Good Pulses to Reset the comparator Alarm

UINT‐32 3B0E R/W  R/W, ‐, R Y R

15119 M4  Good Pulses to Reset the comparator Alarm

UINT‐32 3B0F R/W  R/W, ‐, R Y R

15120 Packed Digital 1=Input(1=B0,24=B23) UINT‐32 3B10 R  R, R, R R15121 Reserved

Page194 of 229 1/25/2013

Page 195: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15122 Packed Digital I/O (1=B0,24=B23) UINT‐32 3B12 R  R, ‐, R R15123 Prove run in progress UINT‐32 3B13 R  R, R, R R15124 Proving meter number xx UINT‐32 3B14 R  R, ‐, R R15125 Prove counts UINT‐32 3B15 R  R, ‐, R R15126 32 bit Status word 02 UINT‐32 3B16 R  R, R, R R15127 of Archive Days to Retrieve UINT‐32 3B17 R/W R/W, R/W, R/W Y R15128 Text Archive Data ‐ Starting Date of 

Requested (YYDDMM)UINT‐32 3B18 R/W R/W, R/W, R/W Y R

15129 32 bit cmd word 02 UINT‐32 3B19 R/W R/W, R/W, R/W R15130 32 Bit Command Word 03 UINT‐32 3B1A R/W R/W, ‐, R R15131 Raw Process Input 1 UINT‐32 3B1B R  R, R, R R15132 Raw Process Input 2 UINT‐32 3B1C R  R, ‐, R R15133 Raw Process Input 3 UINT‐32 3B1D R  R, ‐, R R15134 Raw Process Input 4 UINT‐32 3B1E R  R, ‐, R R15135 Raw Process Input 5 UINT‐32 3B1F R  R, ‐, R R15136 Raw Process Input 6 UINT‐32 3B20 R  R, ‐, R R15137 Raw Process Input 7 UINT‐32 3B21 R  R, ‐, R R15138 Raw Process Input 8 UINT‐32 3B22 R  R, ‐, R R15139 Raw Process Input 9 UINT‐32 3B23 R  R, ‐, R R15140 Raw Process Input 10 UINT‐32 3B24 R  R, ‐, R R15141 Raw Process Input 11 UINT‐32 3B25 R  R, ‐, R R15142 Raw Process Input 12 UINT‐32 3B26 R  R, ‐, R R15143 Raw Process Input 13 UINT‐32 3B27 R  R, ‐, R R15144 Raw Process Input 14 UINT‐32 3B28 R  R, ‐, R R15145 Raw Process Input 15 UINT‐32 3B29 R  R, ‐, R R15146 Raw Process Input 16 UINT‐32 3B2A R  R, ‐, R R15147 Raw Process Input 17 UINT‐32 3B2B R  R, ‐, R R15148 Raw Process Input 18 UINT‐32 3B2C R  R, ‐, R R15149 Raw Process Input 19 UINT‐32 3B2D R  R, ‐, R R15150 Raw Process Input 20 UINT‐32 3B2E R  R, ‐, R R15151 Raw Process Input 21 UINT‐32 3B2F R  R, ‐, R R15152 Raw Process Input 22 UINT‐32 3B30 R  R, ‐, R R15153 Raw Process Input 23 UINT‐32 3B31 R  R, ‐, R R15154 Raw Process Input 24 UINT‐32 3B32 R  R, ‐, R R15155 ‐ 15169 Reserved15200 Size of Text Archive File UINT‐32 3B60 R  R, R, R R15201 Size of Archive File 701 UINT‐32 3B61 R  R, R, R R

Page195 of 229 1/25/2013

Page 196: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15202 Size of Archive File 702 UINT‐32 3B62 R  R, R, R R15203 Size of Archive File 703 UINT‐32 3B63 R  R, R, R R15204 Size of Archive File 704 UINT‐32 3B64 R  R, R, R R15205 Size of Archive File 705 UINT‐32 3B65 R  R, R, R R15206 Size of Archive File 706 UINT‐32 3B66 R  R, R, R R15207 Size of Archive File 707 UINT‐32 3B67 R  R, R, R R15208 Size of Archive File 708 UINT‐32 3B68 R  R, R, R R15209 Size of Archive File 709 UINT‐32 3B69 R  R, R, R R15210 Size of Archive File 710 UINT‐32 3B6A R  R, R, R R15211 Reserved15212 Reserved15213 Archive Allocation Fails to xxth File UINT‐32 3B6D R  R, R, R R15214 Number of Archive File Allocated UINT‐32 3B6E R  R, R, R R15219 Reserved15220 Reserved15221 Meter 1 Batch Size Adjust UINT‐32 3B75 R/W R/W, R/W, R Y R15222 Meter 2 Batch Size Adjust UINT‐32 3B76 R/W R/W, R/W, R Y R15223 Meter 3 Batch Size Adjust UINT‐32 3B77 R/W R/W, R/W, R Y R15224 Meter 4 Batch Size Adjust UINT‐32 3B78 R/W R/W, R/W, R Y R15225 Station Batch Size Adjust UINT‐32 3B79 R/W R/W, R/W, R Y R15226 Meter 1 number of new alarms UINT‐32 3B7A R  R, ‐, R R15227 Meter 2 number of new alarms UINT‐32 3B7B R  R, ‐, R R15228 Meter 3 number of new alarms UINT‐32 3B7C R  R, ‐, R R15229 Meter 4 number of new alarms UINT‐32 3B7D R  R, ‐, R R15230 Station number of new alarms UINT‐32 3B7E R  R, ‐, R R15231 Date YYMMDD of the Most Recent Batch UINT‐32 3B7F R  R, ‐, R R15232 Date YYMMDD of the 2nd Historical 

Batch ReportUINT‐32 3B80 R   R, ‐, R R

15233 Date YYMMDD of the 3rd Historical Batch Report

UINT‐32 3B81 R   R, ‐, R R

15234 Date YYMMDD of the 4th Historical Batch Report

UINT‐32 3B82 R   R, ‐, R R

15235 Date YYMMDD of the 5th Historical Batch Report

UINT‐32 3B83 R   R, ‐, R R

Page196 of 229 1/25/2013

Page 197: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15236 Date YYMMDD of the 6th Historical Batch Report

UINT‐32 3B84 R   R, ‐, R R

15237 Date YYMMDD of the 7th Historical Batch Report

UINT‐32 3B85 R   R, ‐, R R

15238 Date YYMMDD of the 8th Historical Batch Report

UINT‐32 3B86 R   R, ‐, R R

15239 ‐ 15240 Reserved15241 Time HHMMSS of the Most Recent Batch UINT‐32 3B89 R  R, ‐, R R15242 Time HHMMSS of the 2nd Historical 

Batch ReportUINT‐32 3B8A R   R, ‐, R R

15243 Time HHMMSS of the 3rd Historical Batch Report

UINT‐32 3B8B R   R, ‐, R R

15244 Time HHMMSS of the 4th Historical Batch Report

UINT‐32 3B8C R   R, ‐, R R

15245 Time HHMMSS of the 5th Historical Batch Report

UINT‐32 3B8D R   R, ‐, R R

15246 Time HHMMSS of the 6th Historical Batch Report

UINT‐32 3B8E R   R, ‐, R R

15247 Time HHMMSS of the 7th Historical Batch Report

UINT‐32 3B8F R   R, ‐, R R

15248 Time HHMMSS of the 8th Historical Batch Report

UINT‐32 3B90 R   R, ‐, R R

15249 ‐ 15250 Reserved

Page197 of 229 1/25/2013

Page 198: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15251 Running Meter of the Most Recent Batch UINT‐32 3B93 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15252 Running Meter of the 2nd Historical Batch Report

UINT‐32 3B94 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15253 Running Meter of the 3rd Historical Batch Report

UINT‐32 3B95 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15254 Running Meter of the 4th Historical Batch Report

UINT‐32 3B96 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15255 Running Meter of the 5th Historical Batch Report

UINT‐32 3B97 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

Page198 of 229 1/25/2013

Page 199: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15256 Running Meter of the 6th Historical Batch Report

UINT‐32 3B98 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15257 Running Meter of the 7th Historical Batch Report

UINT‐32 3B99 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15258 Running Meter of the 8th Historical Batch Report

UINT‐32 3B9A R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = station

  R, ‐, R R

15259 ‐ 15260 Reserved15261 Batch Number of the Most Recent Batch UINT‐32 3B9D R  R, ‐, R R15262 Batch Number of the 2nd Historical Batch 

ReportUINT‐32 3B9E R   R, ‐, R R

15263 Batch Number of the 3rd Historical Batch Report

UINT‐32 3B9F R   R, ‐, R R

15264 Batch Number of the 4th Historical Batch Report

UINT‐32 3BA0 R   R, ‐, R R

15265 Batch Number of the 5th Historical Batch Report

UINT‐32 3BA1 R   R, ‐, R R

15266 Batch Number of the 6th Historical Batch Report

UINT‐32 3BA2 R   R, ‐, R R

Page199 of 229 1/25/2013

Page 200: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15267 Batch Number of the 7th Historical Batch Report

UINT‐32 3BA3 R   R, ‐, R R

15268 Batch Number of the 8th Historical Batch Report

UINT‐32 3BA4 R   R, ‐, R R

15269 ‐ 15270 Reserved15271 Date YYMMDD of the Most Recent Prove UINT‐32 3BA7 R  R, ‐, R R15272 Date YYMMDD of the 2nd Historical 

Prove ReportUINT‐32 3BA8 R   R, ‐, R R

15273 Date YYMMDD of the 3rd Historical Prove Report

UINT‐32 3BA9 R   R, ‐, R R

15274 Date YYMMDD of the 4th Historical Prove Report

UINT‐32 3BAA R   R, ‐, R R

15275 Date YYMMDD of the 5th Historical Prove Report

UINT‐32 3BAB R   R, ‐, R R

15276 Date YYMMDD of the 6th Historical Prove Report

UINT‐32 3BAC R   R, ‐, R R

15277 Date YYMMDD of the 7th Historical Prove Report

UINT‐32 3BAD R   R, ‐, R R

15278 Date YYMMDD of the 8th Historical Prove Report

UINT‐32 3BAE R   R, ‐, R R

15279 ‐ 15280 Reserved15281 Time HHMMSS of the Most Recent Prove UINT‐32 3BB1 R  R, ‐, R R15282 Time HHMMSS of the 2nd Historical 

Prove ReportUINT‐32 3BB2 R   R, ‐, R R

15283 Time HHMMSS of the 3rd Historical Prove Report

UINT‐32 3BB3 R   R, ‐, R R

Page200 of 229 1/25/2013

Page 201: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15284 Time HHMMSS of the 4th Historical Prove Report

UINT‐32 3BB4 R   R, ‐, R R

15285 Time HHMMSS of the 5th Historical Prove Report

UINT‐32 3BB5 R   R, ‐, R R

15286 Time HHMMSS of the 6th Historical Prove Report

UINT‐32 3BB6 R   R, ‐, R R

15287 Time HHMMSS of the 7th Historical Prove Report

UINT‐32 3BB7 R   R, ‐, R R

15288 Time HHMMSS of the 8th Historical Prove Report

UINT‐32 3BB8 R   R, ‐, R R

15289 ‐ 15290 Reserved15291 Proving Meter of the Most Recent Prove UINT‐32 3BBB R Bit 0 = Meter #1

Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15292 Proving Meter of the 2nd Historical Prove Report

UINT‐32 3BBC R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15293 Proving Meter of the 3rd Historical Prove Report

UINT‐32 3BBD R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

Page201 of 229 1/25/2013

Page 202: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15294 Proving Meter of the 4th Historical Prove Report

UINT‐32 3BBE R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15295 Proving Meter of the 5th Historical Prove Report

UINT‐32 3BBF R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15296 Proving Meter of the 6th Historical Prove Report

UINT‐32 3BC0 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15297 Proving Meter of the 7th Historical Prove Report

UINT‐32 3BC1 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15298 Proving Meter of the 8th Historical Prove Report

UINT‐32 3BC2 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4

  R, ‐, R R

15299 ‐ 15300 Reserved15301 Prove Status of the Most Recent Prove UINT‐32 3BC5 R 0=MF not implemented

1=MF implemented2=Aborted

  R, ‐, R R

Page202 of 229 1/25/2013

Page 203: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15302 Prove Status of the 2nd Historical Prove Report

UINT‐32 3BC6 R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15303 Prove Status of the 3rd Historical Prove Report

UINT‐32 3BC7 R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15304 Prove Status of the 4th Historical Prove Report

UINT‐32 3BC8 R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15305 Prove Status of the 5th Historical Prove Report

UINT‐32 3BC9 R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15306 Prove Status of the 6th Historical Prove Report

UINT‐32 3BCA R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15307 Prove Status of the 7th Historical Prove Report

UINT‐32 3BCB R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15308 Prove Status of the 8th Historical Prove Report

UINT‐32 3BCC R 0=MF not implemented1=MF implemented2=Aborted

  R, ‐, R R

15309 ‐ 15310 Reserved15311 Date YYMMDD of the Most Recent Day UINT‐32 3BCF R  R, ‐, R R15312 Date YYMMDD of the 2nd Historical Daily 

ReportUINT‐32 3BD0 R   R, ‐, R R

15313 Date YYMMDD of the 3rd Historical Daily Report

UINT‐32 3BD1 R   R, ‐, R R

Page203 of 229 1/25/2013

Page 204: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15314 Date YYMMDD of the 4th Historical Daily Report

UINT‐32 3BD2 R   R, ‐, R R

15315 Date YYMMDD of the 5th Historical Daily Report

UINT‐32 3BD3 R   R, ‐, R R

15316 Date YYMMDD of the 6th Historical Daily Report

UINT‐32 3BD4 R   R, ‐, R R

15317 Date YYMMDD of the 7th Historical Daily Report

UINT‐32 3BD5 R   R, ‐, R R

15318 Date YYMMDD of the 8th Historical Daily Report

UINT‐32 3BD6 R   R, ‐, R R

15319 ‐ 15320 Reserved15321 Time HHMMSS of the Most Recent Day UINT‐32 3BD9 R  R, ‐, R R15322 Time HHMMSS of the 2nd Historical Daily 

ReportUINT‐32 3BDA R   R, ‐, R R

15323 Time HHMMSS of the 3rd Historical Daily Report

UINT‐32 3BDB R   R, ‐, R R

15324 Time HHMMSS of the 4th Historical Daily Report

UINT‐32 3BDC R   R, ‐, R R

15325 Time HHMMSS of the 5th Historical Daily Report

UINT‐32 3BDD R   R, ‐, R R

15326 Time HHMMSS of the 6th Historical Daily Report

UINT‐32 3BDE R   R, ‐, R R

15327 Time HHMMSS of the 7th Historical Daily Report

UINT‐32 3BDF R   R, ‐, R R

15328 Time HHMMSS of the 8th Historical Daily Report

UINT‐32 3BE0 R   R, ‐, R R

Page204 of 229 1/25/2013

Page 205: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15329 ‐ 15330 Reserved15331 Running Meter of the Most Recent Day UINT‐32 3BE3 R Bit 0 = Meter #1

Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15332 Running Meter of the 2nd Historical Daily Report

UINT‐32 3BE4 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15333 Running Meter of the 3rd Historical Daily Report

UINT‐32 3BE5 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15334 Running Meter of the 4th Historical Daily Report

UINT‐32 3BE6 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15335 Running Meter of the 5th Historical Daily Report

UINT‐32 3BE7 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15336 Running Meter of the 6th Historical Daily Report

UINT‐32 3BE8 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

Page205 of 229 1/25/2013

Page 206: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15337 Running Meter of the 7th Historical Daily Report

UINT‐32 3BE9 R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15338 Running Meter of the 8th Historical Daily Report

UINT‐32 3BEA R Bit 0 = Meter #1Bit 1 = Meter #2Bit 2 = Meter #3Bit 3 = Meter #4Bit 4 = Station

  R, ‐, R R

15339 ‐ 15340 Reserved15341 Day End Status of the Most Recent Day UINT‐32 3BED R 0=Auto Day End 

1=Force Day End  R, ‐, R R

15342 Day End Status of the 2nd Historical Daily Report

UINT‐32 3BEE R 0=Auto Day End 1=Force Day End

  R, ‐, R R

15343 Day End Status of the 3rd Historical Daily Report

UINT‐32 3BEF R 0=Auto Day End 1=Force Day End

  R, ‐, R R

15344 Day End Status of the 4th Historical Daily Report

UINT‐32 3BF0 R 0=Auto Day End 1=Force Day End

  R, ‐, R R

15345 Day End Status of the 5th Historical Daily Report

UINT‐32 3BF1 R 0=Auto Day End 1=Force Day End

  R, ‐, R R

15346 Day End Status of the 6th Historical Daily Report

UINT‐32 3BF2 R 0=Auto Day End 1=Force Day End

  R, ‐, R R

Page206 of 229 1/25/2013

Page 207: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15347 Day End Status of the 7th Historical Daily Report

UINT‐32 3BF3 R 0=Auto Day End 1=Force Day End

  R, ‐, R R

15348 Day End Status of the 8th Historical Daily Report

UINT‐32 3BF4 R 0=Auto Day End 1=Force Day End

  R, ‐, R R

15349 ‐ 15350 Reserved15351 Batch End Status of the Most Recent Day UINT‐32 3BF7 R 0=Normal Batch End 

1=No Stack Operation Batch End  R, ‐, R R

15352 Batch End Status of the 2nd Historical BatchReport

UINT‐32 3BF8 R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

15353 Batch End Status of the 3rd Historical BatchReport

UINT‐32 3BF9 R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

15354 Batch End Status of the 4th Historical BatchReport

UINT‐32 3BFA R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

15355 Batch End Status of the 5th Historical BatchReport

UINT‐32 3BFB R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

15356 Batch End Status of the 6th Historical BatchReport

UINT‐32 3BFC R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

15357 Batch End Status of the 7th Historical BatchReport

UINT‐32 3BFD R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

Page207 of 229 1/25/2013

Page 208: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15358 Batch End Status of the 8th Historical BatchReport

UINT‐32 3BFE R 0=Normal Batch End 1=No Stack Operation Batch End

  R, ‐, R R

15359 ‐ 15499 Reserved15509 Meter 1 Previous Day Closing Gross Cum. 

TotalUINT‐32 3C95 R   R, ‐, R R

15510 Meter 1 Previous Day Closing Net Cum. Total

UINT‐32 3C96 R   R, ‐, R R

15511 Meter 1 Previous Day Closing Mass Cum. Total

UINT‐32 3C97 R   R, ‐, R R

15512 Meter 1 Previous Day Closing Energy/NSV Cum. Total

UINT‐32 3C98 R   R, ‐, R R

15513 Meter 1 Daily Closing Gross Cum. Total UINT‐32 3C99 R  R, ‐, R R15514 Meter 1 Daily Closing Net Cum. Total UINT‐32 3C9A R  R, ‐, R R15515 Meter 1 Daily Closing Mass Cum. Total UINT‐32 3C9B R  R, ‐, R R15516 Meter 1 Daily Closing NSV Cum. Total UINT‐32 3C9C R  R, ‐, R R15517 Meter 1 Previous Day Product Number UINT‐32 3C9D R  R, ‐, R R15544 Meter 1 comparator Error Resetable 

CountsUINT‐32 3CB8 R   R, ‐, R R

15545 Meter 1 Good Pulses UINT‐32 3CB9 R  R, ‐, R R15546 ‐ 15573 Reserved15578 ‐ 15599 Reserved

15601 ‐ 15699 Meter 2 (Same as 15501 ‐ 15599) UINT‐32 3CF1 R   R, ‐, R R

15701 ‐ 15799 Meter 3 (Same as 15501 ‐ 15599) UINT‐32 3D55 R   R, ‐, R R

15801 ‐ 15899 Meter 4 (Same as 15501 ‐ 15599) UINT‐32 3DB9 R   R, ‐, R R

Page208 of 229 1/25/2013

Page 209: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

15901 ‐ 15999 Station (Same as 15501 ‐ 15599) UINT‐32 3E1D R   R, ‐, R R

IEEE floats needed by OmniCom

17001 Analog Output 1 @ 4 ma Float 4269 R/W R/W, ‐, R N R17002 Analog Output 1 @ 20ma Float 426A R/W R/W, ‐, R N R17003 Analog Output 2 @ 4 ma Float 426B R/W R/W, ‐, R N R17004 Analog Output 2 @ 20ma Float 426C R/W R/W, ‐, R N R17005 Analog Output 3 @ 4 ma Float 426D R/W R/W, ‐, R N R17006 Analog Output 3 @ 20ma Float 426E R/W R/W, ‐, R N R17007 Analog Output 4 @ 4 ma Float 426F R/W R/W, ‐, R N R17008 Analog Output 4 @ 20ma Float 4270 R/W R/W, ‐, R N R17009 Analog Output 5 @ 4 ma Float 4271 R/W R/W, ‐, R N R17010 Analog Output 5 @ 20ma Float 4272 R/W R/W, ‐, R N R17011 Analog Output 6 @ 4 ma Float 4273 R/W R/W, ‐, R N R17012 Analog Output 6 @ 20ma Float 4274 R/W R/W, ‐, R N R17013 Analog Output 7 @ 4 ma Float 4275 R/W R/W, ‐, R N R17014 Analog Output 7 @ 20ma Float 4276 R/W R/W, ‐, R N R17015 Analog Output 8 @ 4 ma Float 4277 R/W R/W, ‐, R N R17016 Analog Output 8 @ 20ma Float 4278 R/W R/W, ‐, R N R17017 Analog Output 9 @ 4 ma Float 4279 R/W R/W, ‐, R N R17018 Analog Output 9 @ 20ma Float 427A R/W R/W, ‐, R N R17019 Analog Output 10 @ 4 ma Float 427B R/W R/W, ‐, R N R17020 Analog Output 10 @ 20ma Float 427C R/W R/W, ‐, R N R17021 Analog Output 11 @ 4 ma Float 427D R/W R/W, ‐, R N R17022 Analog Output 11 @ 20ma Float 427E R/W R/W, ‐, R N R17023 Analog Output 12 @ 4 ma Float 427F R/W R/W, ‐, R N R17024 Analog Output 12 @ 20ma Float 4280 R/W R/W, ‐, R N R

17025 Digital Point 1 Pulses/Unit Float 4281 R/W R/W, ‐, R N R17026 Digital Point 2 Pulses/Unit Float 4282 R/W R/W, ‐, R N R17027 Digital Point 3 Pulses/Unit Float 4283 R/W R/W, ‐, R N R17028 Digital Point 4 Pulses/Unit Float 4284 R/W R/W, ‐, R N R17029 Digital Point 5 Pulses/Unit Float 4285 R/W R/W, ‐, R N R17030 Digital Point 6 Pulses/Unit Float 4286 R/W R/W, ‐, R N R17031 Digital Point 7 Pulses/Unit Float 4287 R/W R/W, ‐, R N R

Page209 of 229 1/25/2013

Page 210: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17032 Digital Point 8 Pulses/Unit Float 4288 R/W R/W, ‐, R N R17033 Digital Point 9 Pulses/Unit Float 4289 R/W R/W, ‐, R N R17034 Digital Point 10 Pulses/Unit Float 428A R/W R/W, ‐, R N R17035 Digital Point 11 Pulses/Unit Float 428B R/W R/W, ‐, R N R17036 Digital Point 12 Pulses/Unit Float 428C R/W R/W, ‐, R N R17037 Digital Point 13 Pulses/Unit Float 428D R/W R/W, ‐, R N R17038 Digital Point 14 Pulses/Unit Float 428E R/W R/W, ‐, R N R17039 Digital Point 15 Pulses/Unit Float 428F R/W R/W, ‐, R N R17040 Digital Point 16 Pulses/Unit Float 4290 R/W R/W, ‐, R N R17041 Digital Point 17 Pulses/Unit Float 4291 R/W R/W, ‐, R N R17042 Digital Point 18 Pulses/Unit Float 4292 R/W R/W, ‐, R N R17043 Digital Point 19 Pulses/Unit Float 4293 R/W R/W, ‐, R N R17044 Digital Point 20 Pulses/Unit Float 4294 R/W R/W, ‐, R N R17045 Digital Point 21 Pulses/Unit Float 4295 R/W R/W, ‐, R N R17046 Digital Point 22 Pulses/Unit Float 4296 R/W R/W, ‐, R N R17047 Digital Point 23 Pulses/Unit Float 4297 R/W R/W, ‐, R N R17048 Digital Point 24 Pulses/Unit Float 4298 R/W R/W, ‐, R N R17049 Front Panel Counter A Pulses/Unit Float 4299 R/W R/W, ‐, R N R17050 Front Panel Counter B Pulses/Unit Float 429A R/W R/W, ‐, R N R17051 Front Panel Counter C Pulses/Unit Float 429B R/W R/W, ‐, R N R

Info: Registers 17052‐17055, 17058,17059,17063  Input is expected in engineering units.

17052 PID 1 RMT SetPt Lo Limit Float 429C R/W R/W, ‐, R N R17053 PID 1 RMt SetPt Hi Limit Float 429D R/W R/W, ‐, R N R17054 PID 1 RMt SetPt @ 4 ma Float 429E R/W R/W, ‐, R N R17055 PID 1 RMt SetPt @ 20ma Float 429F R/W R/W, ‐, R N R17056 PID 1 Primary Gain Float 42A0 R/W R/W, ‐, R N R17057 PID 1 Primary Repeats/min Float 42A1 R/W R/W, ‐, R N R17058 PID 1 Secondary Zero Float 42A2 R/W R/W, ‐, R N R17059 PID 1 Secondary Full Scale Float 42A3 R/W R/W, ‐, R N R17060 PID 1 Secondary Gain Float 42A4 R/W R/W, ‐, R N R17061 PID 1 Secondary Repeats/min Float 42A5 R/W R/W, ‐, R N R17062 PID 1 Startup Ramp % Float 42A6 R/W R/W, ‐, R N R17063 PID 1 Secondary Setpoint Float 42A7 R/W R/W, ‐, R N R17064 PID 1 Shutdown Ramp % Float 42A8 R/W R/W, ‐, R N R17065 PID 1 Minimum Output % Float 42A9 R/W R/W, ‐, R N R17066 PID 1 Deadband % Float 42AA R/W R/W, ‐, R N R

Page210 of 229 1/25/2013

Page 211: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17067 PID 2 RMT SetPt Lo Limit Float 42AB R/W R/W, ‐, R N R17068 PID 2 RMt SetPt Hi Limit Float 42AC R/W R/W, ‐, R N R17069 PID 2 RMt SetPt @ 4 ma Float 42AD R/W R/W, ‐, R N R17070 PID 2 RMt SetPt @ 20ma Float 42AE R/W R/W, ‐, R N R17071 PID 2 Primary Gain Float 42AF R/W R/W, ‐, R N R17072 PID 2 Primary Repeats/min Float 42B0 R/W R/W, ‐, R N R17073 PID 2 Secondary Zero Float 42B1 R/W R/W, ‐, R N R17074 PID 2 Secondary Full Scale Float 42B2 R/W R/W, ‐, R N R17075 PID 2 Secondary Gain Float 42B3 R/W R/W, ‐, R N R17076 PID 2 Secondary Repeats/min Float 42B4 R/W R/W, ‐, R N R17077 PID 2 Startup Ramp % Float 42B5 R/W R/W, ‐, R N R17078 PID 2 Secondary Setpoint Float 42B6 R/W R/W, ‐, R N R17079 PID 2 Shutdown Ramp % Float 42B7 R/W R/W, ‐, R N R17080 PID 2 Minimum Output % Float 42B8 R/W R/W, ‐, R N R17081 PID 2 Deadband % Float 42B9 R/W R/W, ‐, R N R17082 PID 3 RMT SetPt Lo Limit Float 42BA R/W R/W, ‐, R N R17083 PID 3 RMt SetPt Hi Limit Float 42BB R/W R/W, ‐, R N R17084 PID 3 RMt SetPt @ 4 ma Float 42BC R/W R/W, ‐, R N R17085 PID 3 RMt SetPt @ 20ma Float 42BD R/W R/W, ‐, R N R17086 PID 3 Primary Gain Float 42BE R/W R/W, ‐, R N R17087 PID 3 Primary Repeats/min Float 42BF R/W R/W, ‐, R N R17088 PID 3 Secondary Zero Float 42C0 R/W R/W, ‐, R N R17089 PID 3 Secondary Full Scale Float 42C1 R/W R/W, ‐, R N R17090 PID 3 Secondary Gain Float 42C2 R/W R/W, ‐, R N R17091 PID 3 Secondary Repeats/min Float 42C3 R/W R/W, ‐, R N R17092 PID 3 Startup Ramp % Float 42C4 R/W R/W, ‐, R N R17093 PID 3 Secondary Setpoint Float 42C5 R/W R/W, ‐, R N R17094 PID 3 Shutdown Ramp % Float 42C6 R/W R/W, ‐, R N R17095 PID 3 Minimum Output % Float 42C7 R/W R/W, ‐, R N R17096 PID 3 Deadband % Float 42C8 R/W R/W, ‐, R N R17097 PID 4 RMT SetPt Lo Limit Float 42C9 R/W R/W, ‐, R N R17098 PID 4 RMt SetPt Hi Limit Float 42CA R/W R/W, ‐, R N R17099 PID 4 RMt SetPt @ 4 ma Float 42CB R/W R/W, ‐, R N R17100 PID 4 RMt SetPt @ 20ma Float 42CC R/W R/W, ‐, R N R17101 PID 4 Primary Gain Float 42CD R/W R/W, ‐, R N R17102 PID 4 Primary Repeats/min Float 42CE R/W R/W, ‐, R N R17103 PID 4 Secondary Zero Float 42CF R/W R/W, ‐, R N R17104 PID 4 Secondary Full Scale Float 42D0 R/W R/W, ‐, R N R

Page211 of 229 1/25/2013

Page 212: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17105 PID 4 Secondary Gain Float 42D1 R/W R/W, ‐, R N R17106 PID 4 Secondary Repeats/min Float 42D2 R/W R/W, ‐, R N R17107 PID 4 Startup Ramp % Float 42D3 R/W R/W, ‐, R N R17108 PID 4 Secondary Setpoint Float 42D4 R/W R/W, ‐, R N R17109 PID 4 Shutdown Ramp % Float 42D5 R/W R/W, ‐, R N R17110 PID 4 Minimum Output % Float 42D6 R/W R/W, ‐, R N R17111 PID 4 Deadband % Float 42D7 R/W R/W, ‐, R N R17112 Analog Out % 1 Float 42D8 R  R, R, R R17113 Analog Out % 2 Float 42D9 R  R, ‐, R R17114 Analog Out % 3 Float 42DA R  R, ‐, R R17115 Analog Out % 4 Float 42DB R  R, ‐, R R17116 Analog Out % 5 Float 42DC R  R, ‐, R R17117 Analog Out % 6 Float 42DD R  R, ‐, R R17118 Analog Out % 7 Float 42DE R  R, ‐, R R17119 Analog Out % 8 Float 42DF R  R, ‐, R R17120 Analog Out % 9 Float 42E0 R  R, ‐, R R17121 Analog Out % 10 Float 42E1 R  R, ‐, R R17122 Analog Out % 11 Float 42E2 R  R, ‐, R R17123 Analog Out % 12 Float 42E3 R  R, ‐, R R17130 Reserved17131 Reserved17132 Reserved17133 Reserved17134 Reserved17135 Reserved17136 PID 1 Primary Value Float 42F0 R  R, ‐, R R17137 PID 1 Secondary Value Float 42F1 R  R, ‐, R R17138 PID 1 Output % Float 42F2 R  R, ‐, R R17139 PID 1 Primary Setpoint Float 42F3 R  R, ‐, R R17140 PID 1 Secondary Setpoint Float 42F4 R  R, ‐, R R17146 PID 2 Primary Value Float 42FA R  R, ‐, R R17147 PID 2 Secondary Value Float 42FB R  R, ‐, R R17148 PID 2 Output % Float 42FC R  R, ‐, R R17149 PID 2 Primary Setpoint Float 42FD R  R, ‐, R R17150 PID 2 Secondary Setpoint Float 42FE R  R, ‐, R R17156 PID 3 Primary Value Float 4304 R  R, ‐, R R17157 PID 3 Secondary Value Float 4305 R  R, ‐, R R17158 PID 3 Output % Float 4306 R  R, ‐, R R

Page212 of 229 1/25/2013

Page 213: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17159 PID 3 Primary Setpoint Float 4307 R  R, ‐, R R17160 PID 3 Secondary Setpoint Float 4308 R  R, ‐, R R17166 PID 4 Primary Value Float 430E R  R, ‐, R R17167 PID 4 Secondary Value Float 430F R  R, ‐, R R17168 PID 4 Output % Float 4310 R  R, ‐, R R17169 PID 4 Primary Setpoint Float 4311 R  R, ‐, R R17170 PID 4 Secondary Setpoint Float 4312 R  R, ‐, R R17176 Meter 1 Gross Flowrate Full Scale Float 4318 R/W R/W, ‐, R N R17177 Meter 1 Mass Flowrate Full Scale Float 4319 R/W R/W, ‐, R N R17178 Reserved17180 Meter 2 Gross Flowrate Full Scale Float 431C R/W R/W, ‐, R N R17181 Meter 2 Mass Flowrate Full Scale Float 431D R/W R/W, ‐, R N R17182 Reserved17184 Meter 3 Gross Flowrate Full Scale Float 4320 R/W R/W, ‐, R N R17185 Meter 3 Mass Flowrate Full Scale Float 4321 R/W R/W, ‐, R N R17186 Reserved17188 Meter 4 Gross Flowrate Full Scale Float 4324 R/W R/W, ‐, R N R17189 Meter 4 Mass Flowrate Full Scale Float 4325 R/W R/W, ‐, R N R17190 Reserved17192 Station Gross Flowrate Full Scale Float 4328 R/W R/W, ‐, R N R17193 Station Mass Flowrate Full Scale Float 4329 R/W R/W, ‐, R N R17194 Product 1 K0 Float 432A R/W If table select for NGL (40)  R/W, ‐, R Y R

17195 Product 1 K1 Float 432B R/W If table select for NGL (40)  R/W, ‐, R Y R

17196 Product 2 K0 Float 432C R/W If table select for NGL (40)  R/W, ‐, R Y R

17197 Product 2 K1 Float 432D R/W If table select for NGL (40)  R/W, ‐, R Y R

17198 Alarm Deadband % Float 432E R/W R/W, ‐, R N R17199 Transmitter Fail Low Set Point % Float 432F R/W The transmitter fail low set point % for 20.75.02 and 

higher. R/W, ‐, R N R

Page213 of 229 1/25/2013

Page 214: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17200 Transmitter Fail High Set Point % Float 4330 R/W The transmitter fail low set point % for 20.75.02 and higher.

 R/W, ‐, R N R

17203 Product 1 F Factor Float 4333 R/W R/W, ‐, R Y R17204 Product 2 F Factor Float 4334 R/W R/W, ‐, R Y R17205 Product 3 F Factor Float 4335 R/W R/W, ‐, R Y R17206 Product 4 F Factor Float 4336 R/W R/W, ‐, R Y R17207 Product 5 F Factor Float 4337 R/W R/W, ‐, R Y R17208 Product 6 F Factor Float 4338 R/W R/W, ‐, R Y R17209 Product 7 F Factor Float 4339 R/W R/W, ‐, R Y R17210 Product 8 F Factor Float 433A R/W R/W, ‐, R Y R17211 Product 9 F Factor Float 433B R/W R/W, ‐, R Y R17212 Product 10 F Factor Float 433C R/W R/W, ‐, R Y R17213 Product 11 F Factor Float 433D R/W R/W, ‐, R Y R17214 Product 12 F Factor Float 433E R/W R/W, ‐, R Y R17215 Product 13 F Factor Float 433F R/W R/W, ‐, R Y R17216 Product 14 F Factor Float 4340 R/W R/W, ‐, R Y R17217 Product 15 F Factor Float 4341 R/W R/W, ‐, R Y R17218 Product 16 F Factor Float 4342 R/W R/W, ‐, R Y R17235 Product 1 Mole Fraction of Propylene Float 4353 R/W R/W, ‐, R Y R

Product 1 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17236 Product 2 Mole Fraction of Propylene Float 4354 R/W R/W, ‐, R Y RProduct 2 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17237 Product 3 Mole Fraction of Propylene Float 4355 R/W R/W, ‐, R Y RProduct 3 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17238 Product 4 Mole Fraction of Propylene Float 4356 R/W R/W, ‐, R Y RProduct 4 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17239 Product 5 Mole Fraction of Propylene Float 4357 R/W R/W, ‐, R Y R

Page214 of 229 1/25/2013

Page 215: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Product 5 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17240 Product 6 Mole Fraction of Propylene Float 4358 R/W R/W, ‐, R Y RProduct 6 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17241 Product 7 Mole Fraction of Propylene Float 4359 R/W R/W, ‐, R Y RProduct 7 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17242 Product 8 Mole Fraction of Propylene Float 435A R/W R/W, ‐, R Y RProduct 8 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17243 Product 9 Mole Fraction of Propylene Float 435B R/W R/W, ‐, R Y RProduct 9 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17244 Product 10 Mole Fraction of Propylene Float 435C R/W R/W, ‐, R Y RProduct 10 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17245 Product 11 Mole Fraction of Propylene Float 435D R/W R/W, ‐, R Y RProduct 11 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17246 Product 12 Mole Fraction of Propylene Float 435E R/W R/W, ‐, R Y RProduct 12 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17247 Product 13 Mole Fraction of Propylene Float 435F R/W R/W, ‐, R Y RProduct 13 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17248 Product 14 Mole Fraction of Propylene Float 4360 R/W R/W, ‐, R Y R

Page215 of 229 1/25/2013

Page 216: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Product 14 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17249 Product 15 Mole Fraction of Propylene Float 4361 R/W R/W, ‐, R Y RProduct 15 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17250 Product 16 Mole Fraction of Propylene Float 4362 R/W R/W, ‐, R Y RProduct 16 Dissolved Air Correction. (0=No, 1=Yes)

R/W  R/W, ‐, R Y R

17255 Switch Bar Temperature Low Limit Float 4367 R/W R/W, ‐, R Y R17256 Switch Bar Temperature High Limit Float 4368 R/W R/W, ‐, R Y R17257 Switch Bar Temperature Override Value Float 4369 R/W R/W, ‐, R Y R17258 Switch Bar Temperature @ 4mA Float 436A R/W R/W, ‐, R N R17259 Switch Bar Temperature @20mA Float 436B R/W R/W, ‐, R N R17260 Prover Density/Gravity Low Limit Float 436C R/W R/W, ‐, R Y R17261 Prover Density/Gravity High Limit Float 436D R/W R/W, ‐, R Y R17262 Prover Density/Gravity Override Value Float 436E R/W R/W, ‐, R Y R17263 Prover Density/Gravity @ 4mA Float 436F R/W R/W, ‐, R N R17264 Prover Density/Gravity @ 20mA Float 4370 R/W R/W, ‐, R N R17265 Prover Density Temperature Low Limit Float 4371 R/W R/W, ‐, R Y R17266 Prover Density Temperature High Limit Float 4372 R/W R/W, ‐, R Y R17267 Prover Density Temperature Override Float 4373 R/W R/W, ‐, R Y R17268 Prover Density Temperature @ 4mA Float 4374 R/W R/W, ‐, R N R17269 Prover Density Temperature @ 20mA Float 4375 R/W R/W, ‐, R N R17270 Prover Density Pressure Low Limit Float 4376 R/W R/W, ‐, R Y R17271 Prover Density Pressure High Limit Float 4377 R/W R/W, ‐, R Y R17272 Prover Density Pressure Override Float 4378 R/W R/W, ‐, R Y R17273 Prover Density Pressure @ 4mA Float 4379 R/W R/W, ‐, R N R17274 Prover Density Pressure @ 20mA Float 437A R/W R/W, ‐, R N R17275 Prover Density Correction Factor A Float 437B R/W R/W, ‐, R N R17276 Prover Density Constant 1 (K0/D0) Float 437C R/W R/W, ‐, R N R17277 Prover Density Constant 2 (K1/T0) Float 437D R/W R/W, ‐, R N R17278 Prover Density Constant 3 (K2/K) Float 437E R/W R/W, ‐, R N R17279 Pv Density Constant 4 (K18/Tcoef/Tc) Float 437F R/W R/W, ‐, R N R17280 Pv Density Constant 5(K19/Pcoef/Kt1) Float 4380 R/W R/W, ‐, R N R17281 Pv Density Constant 6(K20A/Pcal/Kt2) Float 4381 R/W R/W, ‐, R N R

Page216 of 229 1/25/2013

Page 217: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17282 Pv Density Constant 7 (K20B/Kt3) Float 4382 R/W R/W, ‐, R N R17283 Pv Density Constant 8 (K21A/Pc) Float 4383 R/W R/W, ‐, R N R17284 Pv Density Constant 9 (K21B/Kp1) Float 4384 R/W R/W, ‐, R N R17285 Pv Density Constant 10 (Kr/Kp2) Float 4385 R/W R/W, ‐, R N R17286 Pv Density Constant 11 (Kj/Kp3) Float 4386 R/W R/W, ‐, R N R17288 Product 1 Base Pressure (Pe) Float 4388 R/W R/W, ‐, R Y R17289 Product 2 Base Pressure (Pe) Float 4389 R/W R/W, ‐, R Y R17290 Product 3 Base Pressure (Pe) Float 438A R/W R/W, ‐, R Y R17291 Product 4 Base Pressure (Pe) Float 438B R/W R/W, ‐, R Y R17292 Product 5 Base Pressure (Pe) Float 438C R/W R/W, ‐, R Y R17293 Product 6 Base Pressure (Pe) Float 438D R/W R/W, ‐, R Y R17294 Product 7 Base Pressure (Pe) Float 438E R/W R/W, ‐, R Y R17295 Product 8 Base Pressure (Pe) Float 438F R/W R/W, ‐, R Y R17296 Product 9 Base Pressure (Pe) Float 4390 R/W R/W, ‐, R Y R17297 Product 10 Base Pressure (Pe) Float 4391 R/W R/W, ‐, R Y R17298 Product 11 Base Pressure (Pe) Float 4392 R/W R/W, ‐, R Y R17299 Product 12 Base Pressure (Pe) Float 4393 R/W R/W, ‐, R Y R17300 Product 13 Base Pressure (Pe) Float 4394 R/W R/W, ‐, R Y R17301 Product 14 Base Pressure (Pe) Float 4395 R/W R/W, ‐, R Y R17302 Product 15 Base Pressure (Pe) Float 4396 R/W R/W, ‐, R Y R17303 Product 16 Base Pressure (Pe) Float 4397 R/W R/W, ‐, R Y R17304 Meter 1 Batch Sequence 1 Product 

Gravity AdjustmentFloat 4398 R   R, R, R Y R

17305 Meter 1 Batch Sequence 2 Product Gravity Adjustment

Float 4399 R/W  R/W, R, R Y R

17306 Meter 1 Batch Sequence 3 Product Gravity Adjustment

Float 439A R/W  R/W, R, R Y R

17307 Meter 1 Batch Sequence 4 Product Gravity Adjustment

Float 439B R/W  R/W, R, R Y R

17308 Meter 1 Batch Sequence 5 Product Gravity Adjustment

Float 439C R/W  R/W, R, R Y R

Page217 of 229 1/25/2013

Page 218: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17309 Meter 1 Batch Sequence 6 Product Gravity Adjustment

Float 439D R/W  R/W, R, R Y R

17310 Meter 2 Batch Seq 1/Common Batch Stack Seq 7 Gravity Adjustment

Float 439E R/W Changing the 'Gravity' for the current running batch stack position is not allowed.

 R/W, R, R Y R

17311 Meter 2 Batch Seq 2/Common Batch Stack Seq 8 Gravity Adjustment

Float 439F R/W  R/W, R, R Y R

17312 Meter 2 Batch Seq 3/Common Batch Stack Seq 9 Gravity Adjustment

Float 43A0 R/W  R/W, R, R Y R

17313 Meter 2 Batch Seq 4/Common Batch Stack Seq 10 Gravity Adjustment

Float 43A1 R/W  R/W, R, R Y R

17314 Meter 2 Batch Seq 5/Common Batch Stack Seq 11 Gravity Adjustment

Float 43A2 R/W  R/W, R, R Y R

17315 Meter 2 Batch Seq 6/Common Batch Stack Seq 12 Gravity Adjustment

Float 43A3 R/W  R/W, R, R Y R

17316 Meter 3 Batch Seq 1/Common Batch Stack Seq 13 Gravity Adjustment

Float 43A4 R/W Changing the 'Gravity' for the current running batch stack position is not allowed.

 R/W, R, R Y R

17317 Meter 3 Batch Seq 2/Common Batch Stack Seq 14 Gravity Adjustment

Float 43A5 R/W  R/W, R, R Y R

17318 Meter 3 Batch Seq 3/Common Batch Stack Seq 15 Gravity Adjustment

Float 43A6 R/W  R/W, R, R Y R

17319 Meter 3 Batch Seq 4/Common Batch Stack Seq 16 Gravity Adjustment

Float 43A7 R/W  R/W, R, R Y R

17320 Meter 3 Batch Seq 5/Common Batch Stack Seq 17 Gravity Adjustment

Float 43A8 R/W  R/W, R, R Y R

Page218 of 229 1/25/2013

Page 219: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17321 Meter 3 Batch Seq 6/Common Batch Stack Seq 18 Gravity Adjustment

Float 43A9 R/W  R/W, R, R Y R

17322 Meter 4 Batch Seq 1/Common Batch Stack Seq 19 Gravity Adjustment

Float 43AA R/W Changing the 'Gravity' for the current running batch stack position is not allowed.

 R/W, R, R Y R

17323 Meter 4 Batch Seq 2/Common Batch Stack Seq 20 Gravity Adjustment

Float 43AB R/W  R/W, R, R Y R

17324 Meter 4 Batch Seq 3/Common Batch Stack Seq 21 Gravity Adjustment

Float 43AC R/W  R/W, R, R Y R

17325 Meter 4 Batch Seq 4/Common Batch Stack Seq 22 Gravity Adjustment

Float 43AD R/W  R/W, R, R Y R

17326 Meter 4 Batch Seq 5/Common Batch Stack Seq 23 Gravity Adjustment

Float 43AE R/W  R/W, R, R Y R

17327 Meter 4 Batch Seq 6/Common Batch Stack Seq 24 Gravity Adjustment

Float 43AF R/W  R/W, R, R Y R

17380 Auxiliary Input 1 Low Limit Float 43E4 R/W R/W, ‐, R Y R17381 Auxiliary Input 1 High Limit Float 43E5 R/W R/W, ‐, R Y R17382 Auxiliary Input 1 Override Value Float 43E6 R/W R/W, ‐, R Y R17383 Auxiliary Input 1 @ 4mA Float 43E7 R/W R/W, ‐, R N R17384 Auxiliary Input 1 @ 20mA Float 43E8 R/W R/W, ‐, R N R17385 Auxiliary Input 2 Low Limit Float 43E9 R/W R/W, ‐, R Y R17386 Auxiliary Input 2 High Limit Float 43EA R/W R/W, ‐, R Y R17387 Auxiliary Input 2 Override Value Float 43EB R/W R/W, ‐, R Y R17388 Auxiliary Input 2 @ 4mA Float 43EC R/W R/W, ‐, R N R17389 Auxiliary Input 2 @ 20mA Float 43ED R/W R/W, ‐, R N R17390 Auxiliary Input 3 Low Limit Float 43EE R/W R/W, ‐, R Y R17391 Auxiliary Input 3 High Limit Float 43EF R/W R/W, ‐, R Y R17392 Auxiliary Input 3 Override Value Float 43F0 R/W R/W, ‐, R Y R17393 Auxiliary Input 3 @ 4mA Float 43F1 R/W R/W, ‐, R N R17394 Auxiliary Input 3 @ 20mA Float 43F2 R/W R/W, ‐, R N R17395 Auxiliary Input 4 Low Limit Float 43F3 R/W R/W, ‐, R Y R17396 Auxiliary Input 4 High Limit Float 43F4 R/W R/W, ‐, R Y R

Page219 of 229 1/25/2013

Page 220: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17397 Auxiliary Input 4 Override Value Float 43F5 R/W R/W, ‐, R Y R17398 Auxiliary Input 4 @ 4mA Float 43F6 R/W R/W, ‐, R N R17399 Auxiliary Input 4 @ 20mA Float 43F7 R/W R/W, ‐, R N R

17401 Product 1 Meter 1 Density Correction Factor

Float 43F9 R/W  R/W, ‐, R N R

17402 Product 1 Meter 2 Density Correction Factor

Float 43FA R/W  R/W, ‐, R N R

17403 Product 1 Meter 3 Density Correction Factor

Float 43FB R/W  R/W, ‐, R N R

17404 Product 1 Meter 4 Density Correction Factor

Float 43FC R/W  R/W, ‐, R N R

17405 Product 1 Station Density Correction Factor

Float 43FD R/W  R/W, ‐, R N R

17406 Product 2 Meter 1 Density Correction Factor

Float 43FE R/W  R/W, ‐, R N R

17407 Product 2 Meter 2 Density Correction Factor

Float 43FF R/W  R/W, ‐, R N R

17408 Product 2 Meter 3 Density Correction Factor

Float 4400 R/W  R/W, ‐, R N R

17409 Product 2 Meter 4 Density Correction Factor

Float 4401 R/W  R/W, ‐, R N R

17410 Product 2 Station Density Correction Factor

Float 4402 R/W  R/W, ‐, R N R

17411 Product 3 Meter 1 Density Correction Factor

Float 4403 R/W  R/W, ‐, R N R

Page220 of 229 1/25/2013

Page 221: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17412 Product 3 Meter 2 Density Correction Factor

Float 4404 R/W  R/W, ‐, R N R

17413 Product 3 Meter 3 Density Correction Factor

Float 4405 R/W  R/W, ‐, R N R

17414 Product 3 Meter 4 Density Correction Factor

Float 4406 R/W  R/W, ‐, R N R

17415 Product 3 Station Density Correction Factor

Float 4407 R/W  R/W, ‐, R N R

17416 Product 4 Meter 1 Density Correction Factor

Float 4408 R/W  R/W, ‐, R N R

17417 Product 4 Meter 2 Density Correction Factor

Float 4409 R/W  R/W, ‐, R N R

17418 Product 4 Meter 3 Density Correction Factor

Float 440A R/W  R/W, ‐, R N R

17419 Product 4 Meter 4 Density Correction Factor

Float 440B R/W  R/W, ‐, R N R

17420 Product 4 Station Density Correction Factor

Float 440C R/W  R/W, ‐, R N R

17421 Product 5 Meter 1 Density Correction Factor

Float 440D R/W  R/W, ‐, R N R

17422 Product 5 Meter 2 Density Correction Factor

Float 440E R/W  R/W, ‐, R N R

17423 Product 5 Meter 3 Density Correction Factor

Float 440F R/W  R/W, ‐, R N R

Page221 of 229 1/25/2013

Page 222: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17424 Product 5 Meter 4 Density Correction Factor

Float 4410 R/W  R/W, ‐, R N R

17425 Product 5 Station Density Correction Factor

Float 4411 R/W  R/W, ‐, R N R

17426 Product 6 Meter 1 Density Correction Factor

Float 4412 R/W  R/W, ‐, R N R

17427 Product 6 Meter 2 Density Correction Factor

Float 4413 R/W  R/W, ‐, R N R

17428 Product 6 Meter 3 Density Correction Factor

Float 4414 R/W  R/W, ‐, R N R

17429 Product 6 Meter 4 Density Correction Factor

Float 4415 R/W  R/W, ‐, R N R

17430 Product 6 Station Density Correction Factor

Float 4416 R/W  R/W, ‐, R N R

17431 Product 7 Meter 1 Density Correction Factor

Float 4417 R/W  R/W, ‐, R N R

17432 Product 7 Meter 2 Density Correction Factor

Float 4418 R/W  R/W, ‐, R N R

17433 Product 7 Meter 3 Density Correction Factor

Float 4419 R/W  R/W, ‐, R N R

17434 Product 7 Meter 4 Density Correction Factor

Float 441A R/W  R/W, ‐, R N R

17435 Product 7 Station Density Correction Factor

Float 441B R/W  R/W, ‐, R N R

Page222 of 229 1/25/2013

Page 223: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17436 Product 8 Meter 1 Density Correction Factor

Float 441C R/W  R/W, ‐, R N R

17437 Product 8 Meter 2 Density Correction Factor

Float 441D R/W  R/W, ‐, R N R

17438 Product 8 Meter 3 Density Correction Factor

Float 441E R/W  R/W, ‐, R N R

17439 Product 8 Meter 4 Density Correction Factor

Float 441F R/W  R/W, ‐, R N R

17440 Product 8 Station Density Correction Factor

Float 4420 R/W  R/W, ‐, R N R

17441 Product 9 Meter 1 Density Correction Factor

Float 4421 R/W  R/W, ‐, R N R

17442 Product 9 Meter 2 Density Correction Factor

Float 4422 R/W  R/W, ‐, R N R

17443 Product 9 Meter 3 Density Correction Factor

Float 4423 R/W  R/W, ‐, R N R

17444 Product 9 Meter 4 Density Correction Factor

Float 4424 R/W  R/W, ‐, R N R

17445 Product 9 Station Density Correction Factor

Float 4425 R/W  R/W, ‐, R N R

17446 Product 10 Meter 1 Density Correction Factor

Float 4426 R/W  R/W, ‐, R N R

17447 Product 10 Meter 2 Density Correction Factor

Float 4427 R/W  R/W, ‐, R N R

Page223 of 229 1/25/2013

Page 224: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17448 Product 10 Meter 3 Density Correction Factor

Float 4428 R/W  R/W, ‐, R N R

17449 Product 10 Meter 4 Density Correction Factor

Float 4429 R/W  R/W, ‐, R N R

17450 Product 10 Station Density Correction Factor

Float 442A R/W  R/W, ‐, R N R

17451 Product 11 Meter 1 Density Correction Factor

Float 442B R/W  R/W, ‐, R N R

17452 Product 11 Meter 2 Density Correction Factor

Float 442C R/W  R/W, ‐, R N R

17453 Product 11 Meter 3 Density Correction Factor

Float 442D R/W  R/W, ‐, R N R

17454 Product 11 Meter 4 Density Correction Factor

Float 442E R/W  R/W, ‐, R N R

17455 Product 11 Station Density Correction Factor

Float 442F R/W  R/W, ‐, R N R

17456 Product 12 Meter 1 Density Correction Factor

Float 4430 R/W  R/W, ‐, R N R

17457 Product 12 Meter 2 Density Correction Factor

Float 4431 R/W  R/W, ‐, R N R

17458 Product 12 Meter 3 Density Correction Factor

Float 4432 R/W  R/W, ‐, R N R

17459 Product 12 Meter 4 Density Correction Factor

Float 4433 R/W  R/W, ‐, R N R

Page224 of 229 1/25/2013

Page 225: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17460 Product 12 Station Density Correction Factor

Float 4434 R/W  R/W, ‐, R N R

17461 Product 13 Meter 1 Density Correction Factor

Float 4435 R/W  R/W, ‐, R N R

17462 Product 13 Meter 2 Density Correction Factor

Float 4436 R/W  R/W, ‐, R N R

17463 Product 13 Meter 3 Density Correction Factor

Float 4437 R/W  R/W, ‐, R N R

17464 Product 13 Meter 4 Density Correction Factor

Float 4438 R/W  R/W, ‐, R N R

17465 Product 13 Station Density Correction Factor

Float 4439 R/W  R/W, ‐, R N R

17466 Product 14 Meter 1 Density Correction Factor

Float 443A R/W  R/W, ‐, R N R

17467 Product 14 Meter 2 Density Correction Factor

Float 443B R/W  R/W, ‐, R N R

17468 Product 14 Meter 3 Density Correction Factor

Float 443C R/W  R/W, ‐, R N R

17469 Product 14 Meter 4 Density Correction Factor

Float 443D R/W  R/W, ‐, R N R

17470 Product 14 Station Density Correction Factor

Float 443E R/W  R/W, ‐, R N R

17471 Product 15 Meter 1 Density Correction Factor

Float 443F R/W  R/W, ‐, R N R

Page225 of 229 1/25/2013

Page 226: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17472 Product 15 Meter 2 Density Correction Factor

Float 4440 R/W  R/W, ‐, R N R

17473 Product 15 Meter 3 Density Correction Factor

Float 4441 R/W  R/W, ‐, R N R

17474 Product 15 Meter 4 Density Correction Factor

Float 4442 R/W  R/W, ‐, R N R

17475 Product 15 Station Density Correction Factor

Float 4443 R/W  R/W, ‐, R N R

17476 Product 16 Meter 1 Density Correction Factor

Float 4444 R/W  R/W, ‐, R N R

17477 Product 16 Meter 2 Density Correction Factor

Float 4445 R/W  R/W, ‐, R N R

17478 Product 16 Meter 3 Density Correction Factor

Float 4446 R/W  R/W, ‐, R N R

17479 Product 16 Meter 4 Density Correction Factor

Float 4447 R/W  R/W, ‐, R N R

17482 ‐ 17487 Reserved17501 Meter 1 K‐Factor 1 Float 445D R/W R/W, ‐, R N R17502 Meter 1 K‐Factor 2 Float 445E R/W R/W, ‐, R N R17503 Meter 1 K‐Factor 3 Float 445F R/W R/W, ‐, R N R17504 Meter 1 K‐Factor 4 Float 4460 R/W R/W, ‐, R N R17505 Meter 1 K‐Factor 5 Float 4461 R/W R/W, ‐, R N R17506 Meter 1 K‐Factor 6 Float 4462 R/W R/W, ‐, R N R17507 Meter 1 K‐Factor 7 Float 4463 R/W R/W, ‐, R N R17508 Meter 1 K‐Factor 8 Float 4464 R/W R/W, ‐, R N R17509 Meter 1 K‐Factor 9 Float 4465 R/W R/W, ‐, R N R17510 Meter 1 K‐Factor 10 Float 4466 R/W R/W, ‐, R N R17511 Meter 1 K‐Factor 11 Float 4467 R/W R/W, ‐, R N R17512 Meter 1 K‐Factor 12 Float 4468 R/W R/W, ‐, R N R

Page226 of 229 1/25/2013

Page 227: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

17601 ‐ 17699 Meter 2 (Same as 17501 ‐ 17599) Float 44C1 R/W  R/W, ‐, R R

17701 ‐ 17799 Meter 3 (Same as 17501 ‐ 17599) Float 4525 R/W  R/W, ‐, R R

17801 ‐ 17899 Meter 4 (Same as 17501 ‐ 17599) Float 4589 R/W  R/W, ‐, R R

18127 ‐ 18150 Reserved18177 ‐ 18199 Reserved18510 Reserved18520 Reserved18901 Run Number of the Current Complete 

RunFloat 49D5 R   R, ‐, R R

18902 Forward Pulses of Volumetric Prover Float 49D6 R  R, ‐, R RProver Density of Mass Proving R  R, ‐, R RCorrected Prove Volume of Master Meter Proving

R   R, ‐, R R

18903 Reverse Pulses of Volumetric Prover Float 49D7 R  R, ‐, R RProver Volume of Mass Proving R  R, ‐, R RMaster Meter Volume of Master Meter Proving

R   R, ‐, R R

18904 Total Pulses of Volumetric Prover Float 49D8 R  R, ‐, R RProver Mass Total of Mass Proving R  R, ‐, R RTest Meter Volume of Master Meter Proving

R   R, ‐, R R

18905 Frequence Hertz of Volumetric Prover Float 49D9 R  R, ‐, R RMeter Mass Total of Mass Proving R  R, ‐, R RCorrected Meter Volume of Master Meter Proving

R   R, ‐, R R

Page227 of 229 1/25/2013

Page 228: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

18906 Proving Meter Temperature of the Current Complete Run

Float 49DA R   R, ‐, R R

18907 Proving Meter Pressure of the Current Complete Run

Float 49DB R   R, ‐, R R

18908 ProverTemperature of the Current Complete Run

Float 49DC R   R, ‐, R R

18909 Prover Pressure of the Current Complete Run

Float 49DD R   R, ‐, R R

18910 Density/SG60/API60 of the Current Complete Run

Float 49DE R   R, ‐, R R

18911 Meter Factor of the Current Complete Run

Float 49DF R   R, ‐, R R

18912 Meter Flowrate of Volumetric Prover Float 49E0 R  R, ‐, R RCTSP of Mass Proving R  R, ‐, R RMaster Meter CCFof Master Meter Proving

R   R, ‐, R R

18913 Run Time in Seconds of Volumetric Prover

Float 49E1 R   R, ‐, R R

CPSP of Mass Proving R  R, ‐, R RTest Meter CCFof Master Meter Proving R  R, ‐, R R

18914 CTLP of Mass Proving Float 49E2 R  R, ‐, R RMaster Meter CTL/CTPL of Master Meter Proving

R   R, ‐, R R

18915 CPLP of Mass Proving Float 49E3 R  R, ‐, R RMaster Meter CPL of Master Meter Proving

R   R, ‐, R R

18916 CTLM of Mass Proving Float 49E4 R  R, ‐, R R

Page228 of 229 1/25/2013

Page 229: App 20.75 Database

Application 20.75 Modbus DatabaseUS Liquid ‐ Pulse Meter, KF Curve

Modbus Index

Description Data Type Hex Value

Access Notes Level A,B,C Locked FP

Locked Serial

Test Meter CTL/CTPL of Master Meter Proving

R   R, ‐, R R

18917 CPLM of Mass Proving Float 49E5 R  R, ‐, R RTest Meter CPL of Master Meter Proving R  R, ‐, R R

18918 Master Meter MF of Master Meter Proving

Float 49E6 R   R, ‐, R R

19113 ‐ 19199 Reserved

Page229 of 229 1/25/2013