apollo - aacpmaaacpma.com/equipment/draeger/apollo/pdf's/apollo overview .pdf · apollo...

20
| APOLLO APOLLO OVERVIEW

Upload: others

Post on 22-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

OVERVIEW

Page 2: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Lighting control (dimmer) Location

Screen with user interface

Confirm knob

Fresh gas flow controls

Mains power switch

Ventilator release button

Absorber 1.5L

Footrest

Total flow meter

O2 flush

Writing table

Breathing system

Central brakeDrawers (2)

Auxiliary AC outlet ( D-Vapor only) 2Amp.

Vaporizer units w/ interlock system

Water trap w/ sample line connection

Auxiliary O2 flowmeter

Suction system (optional)

Breathing bag arm

Scavenger

Top shelf

OVERVIEW

Page 3: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Auxiliary outlet panel

Cylinder tank yoke bar

Cooling air filter

Cylinder support bar

Scavenger connector

AC power connection

Gas supply block

Connector for optional halogen lamp

Pressure sensors (covered)

Interface panel

Rear View

OVERVIEW

Page 4: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

APOLLOAPOLLO

Overview

Power Supply Unit

Page 5: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Built-in, uninterruptible power supply which maintains the power supply to the device automatically in the event of a mains failure

Operating time: at least 30 min (typically 90 min), display of remaining battery capacity in %

Material: non-leaking lead gel battery pack with 2 * 12 V 17 amp/hr (AH)

Useful life: approx. 150 hours of operation on battery power

Automatic recharging when mains power connected

Time to charge fully discharged battery pack: < = 10 hours

Two UPS batteries are fitted separately in the machine

The batteries are located behind the power supply

The Apollo performs an automatic battery test every 30 days

Backup battery power

Overview

Page 6: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Rear View Gas Supply Block

1. N2O cylinder connection 5. Air max. 70 L/min connection

2. Air cylinder connection 6. Air pipeline connection

3. O2 cylinder connection 7. N2O pipeline connection

4. O2 pipeline connection

OVERVIEW

Page 7: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Vaporizer Exclusion Systems

Dräger Auto Exclusion 2-VaporizerMount (Optional)This system has an automatic interlock system that ensures only one vaporizer can be used at a time.When one of the two vaporizers is selected for use (opened), the interlock mechanism within that vaporizer’s mounting system is activated automatically, preventing the other vaporizer from being used.

Note: Only vaporizers labeled as “AUTOEXCLUSION” vaporizers are compatible withthe Dräger Auto Exclusion 2-Vaporizer Mount.

OVERVIEW

Page 8: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Dräger Auto Exclusion 3-VaporizerMount (Optional)

Note: Only vaporizers labeled as “AUTOEXCLUSION” vaporizers are compatible withthe Dräger Auto Exclusion 3-VaporizerMount.An adapter is available to connect a SelectatecDesflurane vaporizer to the Dräger Auto Exclusion3-Vaporizer Mount.

Note: The Desflurane vaporizer must be installedin the far left position with the Dräger AutoExclusion 3-Vaporizer Mount. Do not installthe Desflurane vaporizer in the other twomounting positions.

OVERVIEW

Page 9: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

The APL Valve

The APL valve has two functions.The adjustment knob (1) is used to selectbetween spontaneous and manual modes ofventilation. It’s labeled to indicated approximatepressure settings.

For spontaneous ventilation:Pressure is released for spontaneous ventilationwhen the adjustment knob is rotated fullycounterclockwise, when the index mark on the knoblines up with the index mark on the bottom of the APLvalve (2). Spontaneous ventilation eliminates bothresistance to patient exhalation and the need toreadjust back pressure.

Note: The APL valve is automatically excluded from the breathing circuit whenever an automatic ventilator mode is selected. It issuggested that even in automatic ventilation, the APL valve is adjusted to a pressure that is safe for the patient.

OVERVIEW

Page 10: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

The Oxygen Flush Button

A manually operated O2 flush valve is located on the front of the machine (1 ). When actuated, the valve delivers an unmetered flow of at least 35 L/min to the breathing system and breathing bag while bypassing the ventilator. The Apollo does not have to be switched on to use the O2 flush.

• To operate the oxygen flush, push the O2+ button. Oxygen flows into the breathing System without anesthetic gas as long as the button is pushed in.

OVERVIEW

Page 11: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Auxiliary Oxygen Flowmeter

The auxiliary oxygen flowmeter delivers a metered flow of pure oxygen used, for example, in the delivery of oxygen through a nasal cannula. Auxiliary oxygen can be used in any ventilation mode, in Standby, or even if the machine is switched off.

OVERVIEW

Breathing Pressure Gauge

The breathing pressure gauge is used to measure the gas pressure found in the Patient’s breathing circuit.

Page 12: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Monitor Control Panel (MoBi)

The MoBi is a 12 inch color display usingTFT (thin film transistor) technology witha resolution of 800X600. The user and Apollo communicate via the monitor control panel (MoBi). The MoBi display presents system and patient information. It is here that the user sets the parameters and ventilation modes.

Primary User Interface

Monitoring

OVERVIEW

Page 13: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Monitor Control Panel (MoBi) display

Gas measurement

Monitoring

Fresh gas delivery

VentilationSettings

OVERVIEW

Page 14: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Gas Measurement

Will detect what is actually delivered to patient. Automatically calibrates when the system is turned on and then every two hours after that.

WaterLockTM water trap

Optimal positioning of the water trap at the front of the device to allow the filling level to be checked and the container to be emptied more easily

Perfect protection for precise gas measurements

OVERVIEW

Page 15: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Compact Absorber System

Made of high impact plastic

☺ easy to clean – corrosion free

- low weight and heat resistant

Fully detachable - easy to transport

The heated breathing system, helps to eliminate moisture in the breathing system by re-vaporizing it and returning it to breathing circuit.

Results in a more therapeutic gas for the patient.

Gas is heated to a temperature of 32-34 degrees Celsius at 100% relative humidity

OVERVIEW

Page 16: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Compact Absorber System Integrated pneumatic Easy to remove and easy to insert,

and electric interface no external hoses or cables

Active heating No condensation, good breathing gas humidification

Fresh gas decoupled Fresh gas does not influence VT

High degree of leak tightness Optimized for low-flow anesthesia and for a virtually closed system

Absorber volume 1.5 L or Possibility to change during Clic with bypass function operation

Integrated APL valve Fewer individual parts

System volume approx. 3.5 L

Few individual components Easier to assemble

Fixed, built-in valve discs Optimal functionality

New inspiratory/expiratory if turned downward, water will not collect connector 45° angled, between the hose and the connectorswing angle 190°

OVERVIEW

Page 17: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

• absorber volume is only 1.5L• allows for quicker equilibrium

and stabilization of patient• saves time because changes occur more quickly

Compact Absorber System

OVERVIEW

Page 18: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

APL valve

inspiratory valve

expiratory valve

inspiratory nozzle

exspiratory nozzle

PEEP membrane

V2 valve

absorber insert

absorber container

breathing system cover

RV1

RV2

valve plate

breathing system block

Compact Absorber System

OVERVIEW

Page 19: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Enhanced Ventilation

During the automated self-check performed at the beginning of the case, the piston pushes a known volume of gas into an occluded system. At this time it calculates both the compliance of the breathing system and the leakage of the breathing system.

Leakage's above 150 mL are not accepted by the device during self test.

OVERVIEW

Page 20: APOLLO - AACPMAaacpma.com/Equipment/Draeger/Apollo/pdf's/Apollo overview .pdf · APOLLO Built-in, uninterruptible power supply which maintains the power supply to the device automatically

|

APOLLOAPOLLO

Enhanced Ventilation

Respiratory Volume Monitoring

• Respiratory volume is measured by the flow sensors.

• The output from the two flow sensors is converted into readings for:

minute volumetidal volumerespiratory rate

OVERVIEW