  • 8/10/2019 APG43 LMT Access Procedure

    1/7

    APG43 Components: GEP/APUB

    Two SAS connections to the two GED/Diskboards.

    Single SATA connection to the GED/DVDboard.

    SATA/USB connection to the Alarm board.

    Local ethernet port.

    Two public ethernet ports.

    Serial console port.

    Boots from system disk, flash disk or USB.

    GEP - APUB

    S

    AS-1

    SAS-0

    SATA-1, USB-0

    ETH-1

    ETH-0

    USB-1

    SATA-0

    ETH-2, DEBUG

    CONSOLE

    RESET

    POW

    MIASNC

    POW = POWer on

    SNC = System Not Connected

    MIA = Manual Intervention Allowed

    Front connectors:

  • 8/10/2019 APG43 LMT Access Procedure

    2/7

    Local Operation and Maintenance: HyperTerminal Via the console connector on the GEP boards. This

    connection is intended for emergency use only

    Following parameters need to be set: - Connect using: Theconnected COM-connector (usually COM1 or COM2)- Bits per second: 57600- Data bits: 8- Parity: None

    - Stop bits: 1- Flow Control: None

    Press Enter, now the prompt "SAC>" should be seen.

    Remote Operation and Maintenance Same as APG40 (telnet, SSH, FTP, SFTP).

    How to access APG43:ETH-2, DEBUG use a common procedure Eth local IP teminal 192.168.200.x

    need Ethernet cable RJ45/priopreatary connector

    Console Port Serial cableneed Serial cable 9 pin/proprietary connector

  • 8/10/2019 APG43 LMT Access Procedure

    3/7

    LCT

  • 8/10/2019 APG43 LMT Access Procedure

    4/7

  • 8/10/2019 APG43 LMT Access Procedure

    5/7

    WinFiol

  • 8/10/2019 APG43 LMT Access Procedure

    6/7

    CHA Command Handling (OSS RC)

  • 8/10/2019 APG43 LMT Access Procedure

    7/7

    FTP