apg43 lmt access procedure
TRANSCRIPT
-
8/10/2019 APG43 LMT Access Procedure
1/7
APG43 Components: GEP/APUB
Two SAS connections to the two GED/Diskboards.
Single SATA connection to the GED/DVDboard.
SATA/USB connection to the Alarm board.
Local ethernet port.
Two public ethernet ports.
Serial console port.
Boots from system disk, flash disk or USB.
GEP - APUB
S
AS-1
SAS-0
SATA-1, USB-0
ETH-1
ETH-0
USB-1
SATA-0
ETH-2, DEBUG
CONSOLE
RESET
POW
MIASNC
POW = POWer on
SNC = System Not Connected
MIA = Manual Intervention Allowed
Front connectors:
-
8/10/2019 APG43 LMT Access Procedure
2/7
Local Operation and Maintenance: HyperTerminal Via the console connector on the GEP boards. This
connection is intended for emergency use only
Following parameters need to be set: - Connect using: Theconnected COM-connector (usually COM1 or COM2)- Bits per second: 57600- Data bits: 8- Parity: None
- Stop bits: 1- Flow Control: None
Press Enter, now the prompt "SAC>" should be seen.
Remote Operation and Maintenance Same as APG40 (telnet, SSH, FTP, SFTP).
How to access APG43:ETH-2, DEBUG use a common procedure Eth local IP teminal 192.168.200.x
need Ethernet cable RJ45/priopreatary connector
Console Port Serial cableneed Serial cable 9 pin/proprietary connector
-
8/10/2019 APG43 LMT Access Procedure
3/7
LCT
-
8/10/2019 APG43 LMT Access Procedure
4/7
-
8/10/2019 APG43 LMT Access Procedure
5/7
WinFiol
-
8/10/2019 APG43 LMT Access Procedure
6/7
CHA Command Handling (OSS RC)
-
8/10/2019 APG43 LMT Access Procedure
7/7
FTP