ap_building_rules-2012_13_04_2012

Upload: saikiran-sunny

Post on 02-Jun-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    1/69

    Directorate of Town and Country Planning(Government of Andhra Pradesh)

    Hyderabad

    PRESENTATION ONANDHRA PRADESH BUILDING RULES - 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    2/69

    2

    PURPOSE OF BUILDING RULES

    Basic instrument for regulating all building activities

    For facilitating Planned Development

    For maintaining public health, Public safety and publicconvenience

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    3/69

    3

    External aspects (setbacks, height, etc.)

    Building volume (Floor area, Coverage, etc.)

    Standards and specifications of construction

    Building standards and specifications are given as

    per the National Building Code

    PARAMETERS OF BUILDING RULES

    Contd..Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    4/69

    4

    It regulates

    1. Plot size

    2. Road Width

    3. Setbacks

    4. Plot coverage

    5. Floor Area

    6. Height

    7. Parking Area

    8. Enforcement

    9. Restriction of buildings in certain areas,

    PARAMETERS OF BUILDING RULES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    5/69

    5

    Comprehensive Building Rules which are applicable atpresent are--

    PRESENT BUILDING RULES

    G.O. Ms. No. Date Applicability

    86 03-03-2006 HMDA Area

    678 07-09-2007 VUDA & VGTM UDA Area

    302 15-04-2008 Corporations and UDAs

    569 23-08-2008 All Urban Local Bodies

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    6/69

    6

    Since the Building Rules are issued in many GOs for

    regulating developments and building activities, in the

    different ULBs & UDAs in the State

    No. of amendments to various rules were given from time to time

    The content is similar in all the Gos/Rules

    WHY UNIFORM BUILDING RULES ARE REQUIRED?

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    7/69

    7

    Minimal parameters, i.e., only setbacks and height

    stipulated

    A single and Common Table for all types of buildings

    Separate stipulations for old and congested areas

    Rationalized the setbacks for smaller plots

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    8/69

    8

    Building height specified based on area and location viz.,

    Congested areas

    Existing areas

    New and developing areas

    Prohibited areas for High Rise Building

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    9/69

    9

    Provisions made for

    Maintaining greenery

    Flexibility in transferring of setbacks

    Solar Power for Heating and External Lighting

    Structure stability and earthquake resistance in majorcomplexes

    Facilities for Physically Challenged persons in the public

    buildings

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    10/69

    10

    Table-I is deleted since it is pertaining to layouts and separate

    rules for layouts is under preparation

    Modified Table-II and introduced maximum height

    permissible apart from minimum abutting road width required

    for better clarity

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    11/69

    11

    Type/ Use of Building plot permissibleMinimum abutting road

    width required

    (in meters)

    A) SITES IN OLD/EXISTING BUILT-UP AREAS/CONGESTEDAREAS/SETTLEMENT (GRAM KHANTAM/ABADI) (as listed in Category Iof Annexure I)

    Residential Buildings maximum permissible upto 10m height

    Non-residential buildings and mixed occupancies maximum

    permissible up to 12 m height

    6 *

    In Category II Areas of Annexure I

    Residential Buildingsmaximum permissible up to 15 m height

    Non-residential buildings and mixed occupancies maximum

    permissible below 18 m height

    9 *

    TABLE II (AS PER GO.86)

    Contd..Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    12/69

    12

    Type/ Use of Building plot permissibleMinimum abutting road

    width required (in meters)

    B) SITES IN NEW AREAS/ APPROVED LAYOUT AREAS

    The type of buildings & intensity of development shall be w.r.t. the abutting roadwidth, viz.,

    B 1 Non-High Rise Residential Buildings including Apartment Complexes;Buildings with shopping on GF and residences on upper floor; Basic levelsocial amenities like Nursery School / Religious Place / Public Health Center

    / Dispensary / Diagnostic Laboratory/ Police outpost/Post Office/Neighbourhood Library cum Community Center and all buildings up to 15m height

    9 *

    B 2 In addition to B 1 above, High Rise Building/ Complex of height above 18 m

    and up to 24 m; Group Housing Scheme; Primary School, Middle school /Tutorial institution / General Industry / Godown / Petrol/diesel Filling station;High School, Junior College / Commercial Complex, Computer units/ OfficeBuilding, ITES Complex, Nursing Home / Community Hall /

    Function/Marriage Hall / Assembly Hall/Cinema Theater; Serviceestablishment/ Workshop;

    Others not specified in the Table and all non high-rise buildings up to 18 mheight

    12.2

    B 3 In addition to B 1 & B 2 above, High Rise buildings above 24 m and up to 30

    m height; General Degree and other non-professional College /Polytechnic, ITI; Professional College Campus; Multiplex Complexes,Shopping Malls, Hospitals and all non high-rise buildings up to 18 m height

    18

    B 4 In addition to B 1 to B 3 above, High Rise Buildings above 30 m height 24 and above

    TABLE II (AS PER GO.86)

    Andhra Pradesh Building Rules 2012

    ( )

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    13/69

    13

    TABLE II (MODIFIED)

    S. No. Type or Use of Building permissible

    Maximum

    Heightpermissible(including

    parking floor)

    (in meters)

    Minimumabutting

    existing roadwidth required

    (in meters)

    A

    SITES IN OLD/EXISTING BUILT-UP AREAS/CONGESTED AREAS/SETTLEMENT

    (GRAM KHANTAM/ABADI) Annexure-I

    All Residential (other than Group Housing) & Commercial Buildings. For other

    categories the Minimum road width shall be as given in B1 Category 10 9 *

    B SITES IN NEW AREAS / APPROVED LAYOUT AREAS

    B 1

    Non-High Rise (Residential) Buildings including Group Housing (Cellar and / or

    Stilt as permissible + maximum up to 5 floors), Basic level social amenities like

    Nursery School, Primary School / Religious Place /Clinic / Dispensary /Diagnostic Laboratory

    18 9 **

    B 2High Rise Buildings / Complexes, Non High Rise Group Housing (Cellars asapplicable + 6 floors), Group Housing with more than 100 units, GroupDevelopment Scheme; Middle school / Tutorial institution / General Industry /Godown / Petrol / Diesel / Gas Filling Station; High School, Junior College /

    Commercial Complex, Computer units/ Office Building, ITES Complex, NursingHome/ Hospital of not more than 20 beds / Community Hall / Function/MarriageHall / Assembly Hall /Cinema Theater; Service establishment / Workshop;

    Others not specified in the Table and all Non High-Rise buildings up to 18mheight

    24 12

    B 3

    General Degree and other non-professional College / Polytechnic, ITI;

    Professional College Campus; Multiplex Complexes, Shopping Malls (above4000sq.m), Hospitals of more than 20 beds and all Non High-Rise buildings up to18 m height

    30 18

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    14/69

    14

    Introduction of restrictions of building activity for thefollowing areas

    Railways

    Distance from Railway property boundary to the building shall beminimum 30m or as per NOC given by Railway Authority

    Electrical Lines

    For High Tension electrical lines a minimum safety distance (bothhorizontal and vertical) of 3m shall be maintained between thebuilding and high tension electrical lines and 1.5m for low tensionelectrical lines

    The land all along the tower line shall be developed as green belt to

    an extent of the width of tower base and on either side of green beltthere shall be a minimum of 10m wide roads or as defined in theMaster Plan, which ever is higher.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    15/69

    15

    Airport For Building activity within the Restricted Zone / Air Funnel Zone near the

    airport, necessary clearance from the concerned Airport Authority shall beobtained.

    The building heights and other parameters shall be regulated as per thestipulations of the Airport Authority of India as notified in Gazette of IndiaExtraordinary (S.O.1589) dated 30-06-2008

    Irrespective of their distance from the aerodrome, even beyond 22km limit

    from the aerodrome reference point, no radio masts or similar installationexceeding 152m in height shall be erected except with the prior clearancefrom Civil Aviation Authorities.

    In respect of any land located within 1000m from the boundary of MilitaryAirport no building is allowed except with prior clearance from theconcerned airport authority with regard to building height permissible and

    safe distance to be maintained between the building and boundary of theaerodrome.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    16/69

    16

    Other Structures near to Airport

    No chimneys or smoke producing factories shall be constructed within a radius of 8km from the Airport Reference Point

    Slaughter house, Butcheries, Meat shops and Solid Waste disposalsitesand other areas for activities like depositing of garbage whichmay encourage collection of high flying birds, like eagles andhawks, shall not be permitted within 10 km from the Airport

    Reference Point.

    Within a 5km radius of the Aerodrome Reference Point, everystructure / installation / building shall be designed so as to meet thepigeon / bird proofing requirement of the Civil Aviation Authorities.

    Such requirement may stipulate the prohibition of any cavity, niche,or other opening on the exterior of such building / installation /structure so as to prevent the nesting and habitation of pigeon orother birds.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    17/69

    17

    EIA (Environmental Impact Assessment-2006)

    To obtain prior Environmental Clearance (EC) from State

    Environmental Impact Assessment Authority (SEIAA), Ministry ofEnvironment and Forests, Govt. of India for the following

    Building/Construction projects/Area Development projects and Townships

    Sl.No Type A B

    1 Buildings andConstructionProjects

    >20000sq.m and 50ha and or built

    up are>1,50,000sq.m ++

    ++All projects under Item8(b) shallbe appraised as Category B1

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    18/69

    18

    Defense Establishments

    In case of Sites within 500m distance from the boundary of Defense

    Areas / Military Establishments prior clearance of Defense Authorityshall be obtained.

    Oil/Gas Pipelines

    In case of Sites in the vicinity of Oil/Gas pipelines, clearance

    distance and other stipulations of the Respective Authority shall becomplied with.

    The Oil / Gas Authorities shall also specify the clearances requiredstretch wise to Local Body.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    19/69

    19

    Heritage Structures In case of Sites located within the distance up to 100m from protected

    monuments as notified under Archeological Monuments and Ancient Sitesand Remains Act 1955 and as amended no construction is allowed.

    For the Sites located within distance of above 100m and up to 200m from theprotected monuments, the construction is allowed only after obtaining priorpermission from the National Monument Authority.

    For the Sites located within the vicinity of any Heritage Structure notified asper the respective law, the prior clearance from the concerned authorityshall be obtained.

    For the development / redevelopment of any notified Heritage Structure thestipulations as prescribed by the respective authority shall be followed.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    20/69

    20

    Religious Structures

    In case of Sites located within a radius of 100m from the notified religious

    structure as given in the list in Annexure VII / notified from time to time, the

    construction is allowed upto 10m height only.

    For the Sites located within a radius of above 100m and up to 300m from the

    notified religious structure as given in the list in Annexure VII / notified from

    time to time, only non high rise structures are allowed.

    SALIENT FEATURES

    Contd..Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    21/69

    21

    Special Regulations for Banjara Hills & Jubliee Hills

    Areas covered : Block 1 & 2 and part of Block No. 3 of ward no. 8, of

    erstwhile MCH

    For Plots abutting Road No.1, 2 & 3 Banjara Hills andRoad No.36 Jubilee Hills maximum permissible height

    is 30m (only for plots where road widening is given

    free of cost)

    Table I (Type & Height of the Building)

    SALIENT FEATURES

    Contd..

    Sl.No Type of the Building Maximum Height

    1 Individual Residential Buildings /

    Apartment Complexes

    15m (Including Stilt floor)

    2 Commercial buildings 15m

    The building with height beyond 10m in these areas shall be permitted only if

    the plot abuts to a minimum of 12m wide road

    The setbacks shall be as per Table-III and parking & other requirement shall

    be as per these rules.Andhra Pradesh Building Rules 2012

    TABLE III (AS PER G O 86) Permissible Setbacks & Height

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    22/69

    22

    TABLE III (AS PER G.O.86) Permissible Setbacks & Height

    Sl.

    No.

    Plot Size

    (in Sq.mts.)

    Parking

    provision

    Height

    permissible

    (in mts.)

    Building line or minimum front setback

    (in mts) to be leftMinimum

    setbacks

    on

    remaining

    sides(in mts.)

    Up to

    12m

    Above

    12m &

    upto18m

    Above

    18m &

    upto18m

    Above

    24m &

    upto30m

    Above

    30m

    1 2 3 4 5 6 7 8 9 10

    1 Less than 100 - 7 1.5 4 5 6 7.5 -

    2 100 & upto 200 - 10 3 4 5 6 7.5 1.0

    3 Above 200 &

    upto 300

    Stilt parking

    floor

    allowed

    Upto 7 3 4 5 6 7.5 1.0

    Upto 10 3 4 5 6 7.5 1.5

    4 Above 300 &

    Upto 400

    Stilt parking

    floor

    allowed

    Upto 7 3 4 5 6 7.5 1.5

    Upto 12 3 4 5 6 7.5 2.0

    5 Above 400 &

    upto 500

    Stilt parking

    floor

    allowed

    Upto 7 3 4 5 6 7.5 2.0

    Upto 12 3 4 5 6 7.5 2.5

    6 Above 500 &upto 750 Stilt parkingfloor

    allowed

    Upto 7 3 4 5 6 7.5 2.5Upto 12 3 4 5 6 7.5 3.0

    Below 15 3 4 5 6 7.5 3.5

    Contd..Andhra Pradesh Building Rules 2012

    TABLE III (AS PER G O 86) Permissible Setbacks & Height

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    23/69

    23

    Sl.

    No.

    Plot Size

    (in Sq.mts.)

    Parking

    provision

    Height

    permissible

    (in mts.)

    Building line or minimum front setback (in mt.)

    to be leftMinimum

    setbacks on

    remaining

    sides(in mts.)

    Up to

    12m

    Above

    12m &

    upto

    18m

    Above

    18m &

    upto

    18m

    Abov

    e 24m

    & upto

    30m

    Above

    30m

    1 2 3 4 5 6 7 8 9 10

    7 Above 750 &

    upto 1000

    Stilt parking

    + One

    cellar floor

    allowed

    Upto 7 3 4 5 6 7.5 3.0

    Upto 12 3 4 5 6 7.5 3.5

    Below 15 3 4 5 6 7.5 4.0

    8 Above 1000 &upto 1500

    Stilt Parking+ 2 Cellar

    floors

    allowed

    Upto 7 3 4 5 6 7.5 3.5Upto 12 3 4 5 6 7.5 4

    Below 15 3 4 5 6 7.5 5

    Below 18* 3 4 5 6 7.5 6

    9 Above 1500 &

    upto 2500

    Stilt parking

    + 2 Cellar

    floors

    allowed

    Upto 7 3 4 5 6 7.5 4.0

    Below 15 3 4 5 6 7.5 5.0

    Below 18* 3 4 5 6 7.5 6.0

    10 Above 2500 Stilt parking

    + 2 or more

    Cellar floors

    allowed

    Upto 7 3 4 5 6 7.5 5.0

    Below 15 3 4 5 6 7.5 6.0

    Below 18* 3 4 5 6 7.5 7.0

    TABLE III (AS PER G.O.86) Permissible Setbacks & Height

    Andhra Pradesh Building Rules 2012

    TABLE III (MODIFIED)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    24/69

    24

    ( )

    Sl.

    No.

    Plot Size

    (in Sq. m)

    Above

    Up to

    Parking

    provision

    Height

    (in m)

    Permissi

    ble

    Up to

    Building Line or Minimum Front Setback to be left (in m)

    Minimum

    setbacks on

    remaining

    sides

    (in m)

    Abutting Road Width

    Up to

    12m

    Above 12m & up to

    18m

    Above

    18m & up

    to

    24 m

    Above

    24m & up

    to 30m

    Above 30m

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    1

    Less than

    50

    7

    1.5

    1.5

    3

    3

    3

    -

    2

    50-100

    -

    7

    1.5

    1.5

    3

    3

    3

    -

    10

    1.5

    1.5

    3

    3

    3

    0.5

    3

    100 - 200

    -

    10

    1.5

    1.5

    3

    3

    3

    1.0

    4

    200 - 300

    Stilt floor

    7

    2

    3

    3

    4

    5

    1.0

    10

    2

    3

    3

    5

    6

    1.5

    5

    300 - 400

    Stilt floor

    7

    3

    4

    5

    6

    7.5

    1.5

    12

    3

    4

    5

    6

    7.5

    2.0

    6

    400 - 500

    Stilt floor

    7

    3

    4

    5

    6

    7.5

    2.0

    12

    3

    4

    5

    6

    7.5

    2.5

    7

    * 500 - 750

    Stilt floor

    7

    3

    4

    5

    6

    7.5

    2.5

    12

    3

    4

    5

    6

    7.5

    3.0

    15

    3

    4

    5

    6

    7.5

    3.5

    8

    750 - 1000

    Stilt +

    One Cellar

    floor

    7

    3

    4

    5

    6

    7.5

    3.0

    12 3 4 5 6 7.5 3.5

    15 3 4 5 6 7.5 4.0Contd..

    TABLE III (MODIFIED)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    25/69

    25

    Sl.

    No.

    Plot Size

    (in Sq. m)

    Above

    Up to

    Parking

    provision

    Height

    (in m)

    Permissible

    Up to

    Building Line or Minimum Front Setback to be left (in m)

    Minimum

    setbacks on

    remainingsides

    (in m)

    Abutting Road Width

    Up to

    12m

    Above 12m & up to

    18m

    Above

    18m & up

    to

    24 m

    Above24m & up

    to 30m

    Above 30m

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    9

    1000 -

    1500

    Stilt +

    2 Cellar

    floors

    7

    3

    4

    5

    6

    7.5

    3.5

    12

    3

    4

    5

    6

    7.5

    4.0

    15

    3

    4

    5

    6

    7.5

    5.0

    18**

    3

    4

    5

    6

    7.5

    6.0

    10

    1500 -

    2500

    Stilt +

    2 Cellar

    floors

    7

    3

    4

    5

    6

    7.5

    4.0

    15

    3

    4

    5

    6

    7.5

    5.0

    18**

    3

    4

    5

    6

    7.5

    6.0

    11

    Above2500

    Stilt +

    2 or moreCellar

    floors

    7

    3

    4

    5

    6

    7.5

    5.0

    15

    3

    4

    5

    6

    7.5

    6.0

    18**

    3

    4

    5

    6

    7.5

    7.0

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    26/69

    26

    In Table-II, Category-A & B front setback is insisted after widening the road to 9m (incase of plots abutting less than 9m road)

    Proposed to formulate special regulations for Slums/EWS buildings

    Stilt Floor meant for parking is excluded from the permissible height in the aboveTable-III

    For commercial plots having an extent of 500-750sq.m cellar floor for parking may beconsidered

    If the site abuts more than one road, then the front setback should be insisted towardsthe bigger road width and for the remaining side or sides, the setback as at column11 In Table-III shall be insisted

    Height of stilt floor shall not be less than 2.5m and shall not exceed 3.0m.

    In case of parking floors where mechanical system and lift are provided, height ofsuch parking floor shall not be less than 4.5m.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    27/69

    27

    The required organized open space (tot lot) of 5% could be in more thanone location and shall be of minimum width of 3m with a minimum area of15sq.m at one location.

    The transfer of setback from any one side to any other side withoutexceeding overall permissible plinth area, subject to maintaining aminimum 2.5m setback on other side (in case of plots above 750sq.m)

    Narrow Plots is redefined as plot having extent not more than 400sq.m where

    the length is four times of the width of the plot and the setbacks on sidesmay be compensated in front and rear setbacks subject to maintainminimum setback of 1m for buildings height upto 10m and 2m in case ofheight above 10 to 15m without exceeding overall permissible plinth areaand this is not applicable for made up plots

    The space between block to block shall not be considered for organized

    open space (tot lot)

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    28/69

    28

    Additional Requirements for buildings above 12m height

    Report of soil test

    Structural designs and drawings duly certified by Structural

    Engineer/Consultants firm empanelled with Local Authority

    Building Plan and application shall be signed by Owner, Builder, Architect and

    the Structural Engineer with their present and permanent address

    If the construction is being taken up by a Builder, attested copy of registered

    agreement shall be submitted

    Contractor shall submit Risk Insurance Policy for construction period

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    29/69

    29

    RESTRICTIONS ON PROJECTIONS IN MANDATORY OPEN

    SPACES

    Cornice, Chajjas / weather shades only of width not exceeding 60cm shall beallowed in the mandatory setbacks.

    No balcony projections or corridor shall be permitted projecting within themandatory open spaces

    In case of Individual Residential Building in plots more than

    300sq.mIn the front setback only a security guard booth of 2sq.m is allowed.

    Sump, septic tank, well may be allowed in the rear and side open spaces.

    A setback of at least 1.5m from the property or boundary line of the plot shallbe provided for these structures.

    Parking sheds, generator room may be allowed in the rear and side open

    Spaces.The height of these accessory buildings shall not be more than 2.5m and shallnot occupy more than 1/4th of the plot width. These shall be so located thatthey do not hinder the fire safety measures and operations.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    30/69

    30

    REQUIREMENTS FOR HIGH RISE BUILDINGS

    High Rise Buildings / Complexes shall be permissible only in areas other thanthose given in Annexure I (congested areas) & II (prohibited for High Rise

    Buildings).

    Minimum size of plot shall be 2000sq.m.

    High Rise Building shall be accompanied by detailed plans, floor plans of all

    floors and detailed specifications duly certified by a qualified structural

    engineer.Prior Clearance from Airport Authority

    Prior NOC from the Fire & Emergency Services Department

    10% of total site area shall reserved for organized open space at ground level

    open to sky and shall be a minimum width of 3m and minimum area of 50sq.m

    at one location.

    The balcony projection of up to 2m may be allowed projecting onto the openspaces for upper floors from 6m height onwards.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    31/69

    31

    Rules for Multiplex Complexesissued in G.O.Ms.No.486, Dt.7-7-2007 isattached to these rules

    Rules for Hospital Buildings with more than 30m height issued inG.O.Ms.No.2, Dt.3-1-2011 are also attached to these rules.

    Row type housing

    Row houses shall abut internal roads only

    G+1 Floors or 7m height is permissible in plot area upto 100sq.m.

    G+2 Floors or 10m height is permissible in plot area above 100sq.m The setbacks in a row can be interchangeable

    U type buildings (allowed for commercial buildings only) Minimum Plot area shall be 2000sq.m

    Minimum open space on sides and rear shall be

    2m for building height upto 15m,

    3m for building height of 8m7m in case of high rise buildings

    The depth of such courtyard shall be at least 50% of the average buildingdepth and the minimum width shall be 10m.

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    32/69

    32

    Group Development Scheme

    It is reckoned as development of Residential Buildings in a Campus or Site.

    Minimum area of 4000sq.m. and minimum road width of 12m is required.

    They could be row houses, semi-detached, detached Houses, apartment

    blocks or high-rise buildings or mix or combination of the above.

    Simplified Group Development Scheme requirements.

    Deleted Table-V & Residential Enclaves of previous Building Rules.

    SALIENT FEATURES

    Contd..Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    33/69

    33

    Group Development Scheme

    It shall be developed together with buildings and amenities and facilities

    open plots shall not disposed.

    Not applicable for Govt. sponsored housing schemes.

    A through public access of 12m width shall be developed with in the

    applicants site for the convenience of accessibility for other sites. This would

    not apply if there is an existing peripheral road.

    Minimum 3% of proposed built up area shall be developed for common

    amenities and facilities where the proposed units are more than 100

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    34/69

    34

    Parking

    Rationalized Parking requirements for N.P/UDA/ULBs in Table V

    Provision for Mechanical and car lift system are proposed enabling two tier

    parking. The required parking shall be computed accordingly

    In Stilt floor a watchman room and 2 toilets (W.C), with maximum built up

    area of 25sq.m may be allowed. Such space shall not be disposed and shall

    be part of common facility of the complex.

    The width of Driveway specified as 4.5m

    SALIENT FEATURES

    Contd..Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    35/69

    35

    Parking

    In case where the permissible set back is less than 4.6m, the pillars position

    in stilt floor shall be so designed that there shall be clear space of 3.6m(excluding Greenery) for movement of vehicles.

    Cellar shall be with a set back from the property line as follows:

    Minimum of 1.5m in the sites of extent of less than 1000sq.m,

    2m in the sites of extent of more than 1000sq.m and less than 2000sq.m

    3m in the sites of extent of more than 2000sq.m.

    In case of more than one cellar, 0.5m additional setback for every

    additional cellar floor shall be insisted.

    Up to 10% of cellar may be utilised for utilities and non-habitation purpose

    like A/C Plant room, Generator room, STP, Electrical installations, Laundry,

    etc,

    SALIENT FEATURES

    Andhra Pradesh Building Rules 2012

    TABLE - V

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    36/69

    36

    TABLE V

    Sl.No Category of building/activity

    Parking area to be provided as percentage of total built up area

    HMDA AreaAll Municipal Corporations &

    UDA AreasMunicipalities/ N.Ps/ G.Ps.

    other than UDA Areas

    GHMC

    Municipalities/N.Ps/ G.Ps.

    inHMDA Area

    All MunicipalCorporations

    Municipalities

    / N.Ps/ G.Ps. inUDA Areas

    Selection &SpecialGrade

    Municipalities

    OtherMunicipaliti

    es/N.Ps/ G.Ps.

    1 2 3 4 5 6 7 8

    1 Multiplexes 60 50 60 50 60 50

    2 Shopping Malls (above 4000

    sq.m), Information TechnologyEnabling Services Complexes

    60 50 50 40 40 30

    3 Hotels, restaurants, lodges,Cinema halls, businessbuildings, other commercialbuildings, Kalyana

    Mandapams, Offices, & High-Rise Buildings / Complexes ofNon Residential Category

    40 30 30 25 25 25

    4 Residential Apartment

    Complexes, Hospitals,Institutional buildings, Industrialbuildings, Schools, Colleges,

    other educational buildings &Godowns & Others

    30 20 20 20 20 20

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    37/69

    37

    ENCOURAGEMENT FOR PROVISION OF PARKING

    COMPLEXESIncentives like relaxation in setbacks, fee, moratorium on property tax are

    proposed

    Provisions for amenities and facilities in all buildings as per NBC

    introducedBuilding requirements like size and area of habitable rooms, bath rooms andkitchen etc. shall be as per NBC

    In High Rise Buildings Power Generator, Solar Water Heating System shall beprovided

    CONCESSIONS IN ROAD WIDENING CASESEntitled for TDR or

    Extra floor with equivalent built up area allowed or

    Concessions in setback including front setbackIn case of High rise Buildings the concessions in setbacks, other than the frontsetback would be considered

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    38/69

    38

    TRANSFERABLE DEVELOPMENT RIGHTS (TDR)

    TDR means an award specifying the built up area an owner of a site or plot

    can sell or dispose or utilize elsewhere, in lieu of surrendering land free of

    cost which is required to be set apart or affected for public purpose as per

    the Master Plan or in road widening or covered in recreational use zone, etc.

    TDR can be awarded only when such lands are transferred to the local body

    / Urban Development Authority as the case may be by way of registered gift

    deed.

    The award would be in the form of a TDR certificate issued by the Competent

    Authority / Sanctioning Authority.

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    39/69

    39

    TRANSFERABLE DEVELOPMENT RIGHTS (TDR)

    Norms

    For the Master Plan Road / Road Development Plan undertaken and

    developed: equivalent to 200% of built up area of such area surrendered.

    For conservation and development of lakes / water bodies / nalas

    foreshores & Recreational buffer development with greenery, etc: equivalent

    to 100% of built up area of such recreational buffer area developed at his

    cost.

    For Heritage buildings and heritage precincts maintained with adaptive

    reuse: equivalent to 100% of built up area of such site area

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    40/69

    40

    BUILDING PERMIT/LICENSE FEES

    The Sanctioning Authority shall along with the Building Application levy and

    collect 2% of the Building Permit / License fees, subject to a maximum of

    Rs.10,000 as initial fees.

    The balance Building Permit / License Fees together with other fees and

    Charges shall be levied and collected before the issue of

    permission/sanction.

    In case of rejection of building application, the above initial fees would be

    forfeited.

    No fees and charges would be levied for parking spaces provided in any

    floor.

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    41/69

    41

    LEVY OF SPECIAL FEES AND OTHER PROVISIONS FORCERTAIN AREAS

    The Sanctioning Authority with the specific approval of the Government

    may, when implementing such Projects, levy Special fees and other fees /

    charges for lands / sites / premises abutting or in the vicinity of the Ring

    Road or other highways / major roads or the Mass Rail Transit System / Light

    Rail Transit / MMTS route indicated in the Master Plan, at the rates and

    procedure prescribed by the Government.

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    42/69

    42

    CITY LEVEL INFRASTRUCTURE IMPACT FEES APPLICABLE INCERTAIN CASES

    City level Infrastructure Impact fees is rationalized and given at Table-VI

    No levy of city level impact fee for The first 15m height of the building

    For Multiplexes the rates given in the Multiplex Rules shall be applicable

    This is not applicable for Government Departments and Public Agencies

    like Urban Development Authority, APIIC, Local Bodies and HMWSSB.

    The amount levied and collected shall be credited and maintained in a

    separate escrow account and 50% of it shall be utilised for development of

    infrastructure in the same area and balance amount is to be utilised

    towards improvement of city level capital infrastructure.

    Andhra Pradesh Building Rules 2012

    TABLE - VI

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    43/69

    43Contd..

    Areas

    Height (No. of Floors), Use of the Building and Rate in Rs. per sq. m of Built Up Area

    Above 15 m &

    up to 7floors

    Above 7 floors &

    up to 10 floors

    Above 10 floors &

    up to 17 floorsAbove 17 floors

    Residentia

    l

    Commercial, Offices,ITES, Institutional,

    Educational & Others

    (except Industrial) Residentia

    lCommercial,

    Offices, ITES,Institutional,

    Educational &

    Others (except

    Industrial)Residentia

    l

    Commercial, Offices,ITES, Institutional,

    Educational & Others

    (except Industrial) Residentia

    l

    Commercial,

    Offices, ITES,

    Institutional,

    Educational &

    Others

    (except

    Industrial)

    1 2(a) 2(b) 3(a) 3(b) 4(a) 4(b) 5(a) 5(b)

    HMDA Area

    GHMC 500 1000 750 1500 1500 2500 3000 5000

    Municipalities 250 500 500 1000 1000 2000 2000 4000

    G.P Areas 175 250 350 500 750 1000 1500 2000

    UDA Areas

    Municipal

    Corporations350 500 500 1000 1000 2000 2000 3000

    Rest of the UDAs 175 350 350 500 750 1000 1500 2000

    Other than UDA Areas

    Municipal

    Corporations350 500 500 800 1000 1500 2000 2000

    Municipalities

    Sel/Spl/1stgrade150

    350

    250

    500

    400

    1000

    800

    1500

    2nd/3rd/N.Ps/G.Ps 100 200 200 300 300 500 500 1000

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    44/69

    44

    INCENTIVES

    Item Rebate in Property Tax

    Install and use solar heating and lighting system 10%

    Under take both Recycling of waste water andRain Water Harvesting Structures

    10%

    Andhra Pradesh Building Rules 2012

    TECHNICAL APPROVAL FROM COMPETENT AUTHORITY

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    45/69

    45

    TECHNICAL APPROVAL FROM COMPETENT AUTHORITY

    HMDA / UDA Areas:

    In case of areas falling under the jurisdiction of HMDA /UDA, the

    development control powers shall be as per the delegation issued by the

    concerned HMDA / UDA from time to time.

    Areas not covered under HMDA / UDA Areas:

    Where the Town Planning Section Head is below the cadre of Deputy

    Director, the Sanctioning Authority is empowered to sanction the building

    permission up to 10m height in plot area upto 300sq.m, in the sites where the

    proposed activity is permissible in normal course as per Zoning Regulations.

    Contd..Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    46/69

    46

    If the site area is above 300sq.m and upto 1000sq.m. prior Technical

    Approval from the concerned Regional Deputy Director shall be obtained

    where the proposed activity is permissible in normal course as per Zoning

    Regulations.

    Where the Town Planning Section Head is in the cadre of Deputy Director or

    above, the Sanctioning Authority is empowered to sanction the building

    permission in plot area upto 1000sq.m, in the sites where the proposed

    activity is permissible in normal course as per Zoning Regulations.

    Other than i & ii above the proposals of building approvals shall be

    submitted to The Director of Town and Country Planning for prior Technical

    Approval.

    Contd..Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    47/69

    47

    In the Gram Panchayat areas covered under sanctioned GTP Scheme the

    Sanctioning Authority is empowered to sanction the individual residential

    building permission up to 10m height in plot area upto 300sq.m, in the sites

    where the proposed activity is permissible in normal course as per Zoning

    Regulations. In respect of other cases prior Technical Approval shall be

    obtained from the Competent Authority i.e. Director of Town & Country

    Planning.

    In Case of Group Development, Group Housing Schemes like Cluster

    Housing / Row Housing / Semidetached Housing Schemes and Gated

    Community, Technical approval from the Competent Authority is required to

    be obtained.

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    48/69

    48

    HIGH RISE BUILDING COMMITTEE

    a) Greater Hyderabad Municipal Corporation (GHMC) /

    Greater Vishakapatnam Municipal Corporation (GVMC) /

    Vijayawada Municipal Corporation (VMC).

    1 Chief City Planner/Town Planning Section HeadMember

    Convener

    2 Engineering Section Head Member

    3 Director of Town & Country Planning or his nominee Member

    4 Town Planning Section Head of UDA or his nominee Member

    The Committee shall give the recommendations to the Commissioner.

    Andhra Pradesh Building Rules 2012

    HIGH RISE BUILDING COMMITTEE

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    49/69

    49

    HIGH RISE BUILDING COMMITTEE

    b) Hyderabad Metropolitan Development Authority (HMDA) /

    All UDAs (Other than the area covered in aabove.)

    1 Head of the Town Planning wing of concerned UDAMember

    Convener

    2Town Planning Section Head or his nominee of

    concerned ULBMember

    3 Engineering Section Head of concerned UDA / ULB Member

    4Director of Town & Country Planning or his

    nominee.Member

    The Committee shall give the recommendations to the MetropolitanCommissioner / Vice Chairman.

    Andhra Pradesh Building Rules 2012

    HIGH RISE BUILDING COMMITTEE

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    50/69

    50

    HIGH RISE BUILDING COMMITTEE

    c) Other Municipal Corporations / Municipalities /

    Nagar Panchayats (Other than the area covered in a& b

    above i.e. DT&CP Jurisdiction)

    1 Town Planning Section Head of concerned ULBMember

    Convener

    2 Commissioner of concerned ULB Member

    3 Regional Deputy Director of Town Planning Member

    4 Superintendent Engineer Public Health Member

    5Senior Practicing Architect / Planner nominated by

    DT&CP

    Member

    The Committee shall give the recommendations to the Director of Town &

    Country Planning

    Andhra Pradesh Building Rules 2012

    HIGH RISE BUILDING COMMITTEE

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    51/69

    51

    HIGH RISE BUILDING COMMITTEE

    d) Gram Panchayats covered in Sanctioned Master Plan Area.

    (Other than the area covered in a,b& cabove i.e.

    DT&CP Jurisdiction)

    1 Regional Deputy Director of Town PlanningMember

    Convener

    2 Superintendent Engineer Public Health Member

    3Senior Practicing Architect / Planner nominated by

    DT&CPMember

    The Panchayat Secretary shall submit the proposal through the concerned

    RDDTP to place before the committee and the committee shall give therecommendations to the Director of Town & Country Planning

    Andhra Pradesh Building Rules 2012

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    52/69

    52

    OCCUPANCY CERTIFICATE (OC) Occupancy Certificate shall be mandatory for all buildings.

    Partial OC may be considered by the Sanctioning authority on merits i.e.

    flats / units or area within a complex which have fulfilled all therequirements in addition to basic facilities like lifts water supply, sanitation,

    drainage, roads, common lighting etc

    In respect of individual buildings in plots up to 100sq.m with height up to 7m

    obtaining OC is optional

    Following aspects to be considered for OC

    No. of Floors

    External setbacks

    Usage of the building

    Parking space provision

    Abutting road width

    Andhra Pradesh Building Rules 2012

    OCCUPANCY CERTIFICATE (OC)

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    53/69

    53

    OCCUPANCY CERTIFICATE (OC)

    The Sanctioning Authority shall communicate the approval or refusal of the

    Occupancy Certificate within 15days

    The Sanctioning Authority is empowered to compound the offence in

    relation to setbacks violations (other than the front setback) in respect of

    non high rise buildings only up to 10%

    For all high rise buildings, the work shall be subject to inspection by the Fire

    and Emergency Service Department and the Occupancy Certificate shallbe issued only after clearance from the Fire and Emergency ServiceDepartment

    The functional/line agencies dealing with electric power, water supply,

    drainage and sewerage shall not give regular connections to the building

    unless such Occupancy Certificate is produced, or alternatively maycharge 3 times the rate till such time Occupancy Certificate is produced.

    Andhra Pradesh Building Rules 2012

    OCCUPANCY CERTIFICATE (OC)

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    54/69

    54

    OCCUPANCY CERTIFICATE (OC)

    The above condition shall also be applicable to all unauthorized

    constructions and buildings constructed without sanctioned building plan.In addition to the above, the Local Body shall collect every year two times

    the property tax as penalty from the owner/occupier.

    The Registration Authority shall register only the permitted built up area as

    per the sanctioned building plan and only upon producing and filing a

    copy of such sanctioned building plan.

    The financial agencies/institutions shall extend loan facilities only to the

    permitted built up area as per the sanctioned building plan.

    Andhra Pradesh Building Rules 2012

    ENFORCEMENT

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    55/69

    55

    ENFORCEMENT

    The Enforcement Authority concerned shall be wholly and severally

    responsible for ensuring and maintaining the right of way / width of the road

    and building restrictions as given in these Rules.

    The Enforcement Authority shall summarily remove any violation or

    deviation in building construction in maintaining the road widths and

    building line.

    In respect of apartment complexes, shopping complexes and all high risebuildings, periodical inspections shall be carried out

    Any person or anybody including the Govt. are carries out development in

    contravention of the rules shall be punished with imprisonment for a term

    which may extend to 3 years or

    A fine which may extend to 10% of the land value or building as fixed by

    the registration dept.

    Andhra Pradesh Building Rules 2012

    ENFORCEMENT

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    56/69

    56

    ENFORCEMENT

    Constitution of Town Planning and Building Tribunal:

    The Government shall constitute a Town Planning and Building Tribunal for

    dealing with all town planning, enforcement and building issues by making

    necessary amendments to the corresponding Acts if required.

    Constitution of Building Ombudsman:

    The Government may constitute a Building Ombudsman for dealing with all

    complaints of building violations, shortfall in building standards, services

    and specifications and safety aspects. The Government shall separately

    work out the procedure, role and details of the functioning of the Building

    Ombudsman.

    Andhra Pradesh Building Rules 2012

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    57/69

    LICENSING OF REAL ESTATE COMPANIES DEVELOPERS BUILDERS TOWN

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    58/69

    58

    LICENSING OF REAL ESTATE COMPANIES, DEVELOPERS, BUILDERS, TOWNPLANNERS, ENGINEERS & OTHER TECHNICAL PERSONNEL MANDATORY

    No developer / builder / real estate firm or company / engineer / town

    planner/other technical personnel shall be allowed to undertakedevelopment/do business / practice in a Municipal Corporation / UDA /

    Municipal Area unless they are licenced with the sanctioning authority of

    the respective area.

    Architects shall be required to be registered with the Council of

    Architecture.

    The engaging of the services of a licenced developer / builder shall be

    mandatory for Apartment Buildings, Group Housing, all types of Group

    Development Schemes, all High-Rise Buildings and all Commercial

    Complexes.

    Andhra Pradesh Building Rules 2012

    LICENSING OF REAL ESTATE COMPANIES DEVELOPERS BUILDERS TOWN

    SALIENT FEATURES

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    59/69

    59

    LICENSING OF REAL ESTATE COMPANIES, DEVELOPERS, BUILDERS, TOWNPLANNERS, ENGINEERS & OTHER TECHNICAL PERSONNEL MANDATORY

    Absence of the above or suppressing of the above facts or in the case of

    other licences and other technical personnel who violate the conditions

    would invite penal action including debarring of the real estate

    firm/development firm / company from practice in the local authority area

    for 5 years besides prosecution under the relevant laws / code of conduct

    by the sanctioning authority.

    Any licenced developer / builder / other technical personnel who

    undertake construction in violation of the sanctioned plans shall be black-

    listed and this, this would entail cancellation of their licence besides being

    prosecuted under the relevant laws / code of conduct.

    Andhra Pradesh Building Rules 2012

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,

    302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

    RULE NO / MODIFIED

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    60/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    1 2 3 4 5 6

    1 3 & 4 of G.O.86,

    678,302 & 569

    3. Restriction on Minimum Building

    Plot Size along abutting roads in new

    developments and layouts

    4.1 Minimum Approach road

    requirement for sites in new

    areas/layout areas:

    4.2 Access conditions & Requirements

    for plots/sites abutting Ring roads /

    Highways / Bypass Roads of 30 m and

    above identified in the Master Plan /Zonal Development Plan:

    -

    Deleted As the Rule pertains to layouts

    2 5 (b) (ii) of

    G.O.302,678 &

    569

    5. Restrictions of building activity in

    vicinity of certain areas

    b) (ii)100 meters from the River

    edge outside Municipal Corporation

    /Municipal limits and 50 meters within

    Municipal Corporation/ Municipal

    limits. No permanent constructions /

    structures will be permitted within the

    above-mentioned buffer zone.

    3 (a) (ii) (1) 45m from the edge of the

    River outside the

    Municipal Corporation /

    Municipality / Nagara

    Panchayat limits and 30m

    with in the Municipal

    Corporation /

    Municipality / Nagara

    Panchayat limits.

    M.C. Rajahmundry has informed

    that no. of structures are existing

    very near to Godavari River. As they

    are existing since long time and to

    avoid unauthorized construction he

    requested to reduce the buffer at

    least to 10m. In view of the above

    modification is considered

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,

    302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    61/69

    SL.NORULE NO /

    G.O.Ms.NoPROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    3 5 (g) (i) In Case of Bajanra Hills and Jubilee Hills

    there is height ceiling of 15m for both

    residential and commercial buildings

    the height beyond 10m in these areas

    shall be permitted only if the plots

    abuts to minimum 40ft wide road.

    The above provision shall not be

    applicable to Apartment complexes

    3 (j) Apartment Complexes and Institutional Buildings

    are also permissible

    4 7 Table-III

    G.O.86,

    678,302 &

    569

    1. less than 100sq.m site area Front

    setback is varying from 1.5m to 7.5m

    and setback on other side is varying

    from 0m to 1.5m

    2. 100-200sq.m site area Front setback

    is varying from 3m to 7.5m and setback

    on other side is 1m

    3. 200- 300sq.m site area Front

    setback is varying from 3m to 7.5m and

    setback on other side is 1m to 1.5m

    5 Table-III 1. less than 50sq.m site area Front setback is

    varying from 1.5m to 3m and on other sides no

    setback

    2. 50-100sq.m site area Front setback is varying

    from 1.5m to 3m and on other side setback is

    varying from 0m to 0.5m

    3. 100-200sq.m site area Front setback is varying

    from 1.5m to 3m and on other side is 1m on other

    side setback is varying 1m

    4. 200-300sq.m site area Front setback is varying

    from 2m to 6m and on other sides varying from

    1m to 1.5m

    In addition to above the plot size group are made

    equal with G.O.86

    Smaller Plots abutting to

    roads of higher width are

    unable to leave the required

    front setbacks due to high

    front setback. In order to

    remove the difficulty faced

    by small plots holder, and to

    encourage compliance of the

    building approvals the front

    setback is reduced for plots

    up to 300m site area to cater

    the needs of the small plot

    holders.

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    62/69

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    63/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    7 7.1(b) of

    G.O.86, 678,

    302 & 569

    Stilt parking floor permissible is

    exclusive of height of building upto 15mts. height of stilt floor

    shall not exceed 3.0mt. In case of

    parking floors where mechanical

    system and lift are provided,

    height of such parking floor upto

    4.0mt. could be considered.

    5(f) (ix) iii. Height of stilt floor shall

    not be less than 2.5m. Incase of parking floors

    where mechanical system

    and lift are provided, height

    of such parking floor shall

    not be less than 4.5m.

    Maximum height of the stilt floor

    is removed and only minimumheight is indicated as 2.5m to

    have a better clarity

    8 9.6 Table-IV

    of

    G.O.86,678,

    G.O. 302

    G.O. 569

    For high rise buildings of height

    above 50m alround setback is

    16m and abutting road width

    30m

    For the high rise buildings of

    height more than 40m approval

    of the Govt. is required

    For the high rise buildings of

    height more than 30m approval

    of the Govt. is required

    7(a)(ix) Required setback for the

    buildings of height up to

    55m is specified and after

    55m 0.5m additional

    setback for every 5m of

    height shall be insisted

    It is desirable to have more

    setbacks for increasing heights of

    buildings beyond certain height

    And height restrictions is deleted

    in respect of Municipal

    Corporations (G.O.302) and

    Municipalities (G.O.569) in order

    to have uniform policy

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    64/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    9 7.1(g)(xiv)

    G.O.86, 678,

    302 & 569

    For narrow plots, Where

    the length 4 times the

    width of the plot the

    setbacks on sides may be

    compensated in front

    and rear setbacks so as

    to ensure that the

    overall aggregate

    setbacks are maintained

    in the site, subject to

    maintaining a minimum

    of 1m on each side.

    5(f)(x) For narrow plots having extent not more

    than 400sq.m and where the length is 4

    times of the width of the plot, the

    setbacks on sides may be compensated

    in front and rear setbacks so as to

    ensure that

    the overall aggregate setbacks are

    maintained in the site, subject to

    maintaining a minimum of side setback

    of 1m in case of buildings of height up

    to 10m and minimum of 2m in case of

    buildings of height

    above 10m and up to 15m without

    exceeding overall permissible plinth

    area. (This Rule shall not be applicable

    for made-up plots).

    This rule is being

    exploited by the

    applicants by making the

    plots as narrow plots by

    amalgamating the plots to

    fulfill the norms of the

    narrow plots. Due to this

    the buildings with height

    of 18m with only 1m

    setback is being

    constructed due to which

    the lighting and

    ventilation to the

    neighboring buildings is

    deprived. Hence this is

    suitably modified.

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    65/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    10 8 of

    G.O.86,678,3

    02 & 569

    ENCOURAGEMENT FOR

    BUILDINGS WITH U-Type

    CENTRAL COURTYARDS

    12 BUILDINGS WITH U-Type

    CENTRAL COURTYARD for

    commercial use

    Previously there was no

    mention of use of the building.

    As per the prevailing rules the

    U-Shape building is

    permissible with 1m side

    setbacks. There may not be a

    problem to allow such buildings

    in commercial area but in

    residential areas the lighting and

    ventilation is reduced to the

    neighboring buildings. Hence it

    is restricted to commercial

    buildings in the modified rules

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    66/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    11 15 of

    G.O.86,678,

    302 & 569

    GRANT OF TRANSFERABLE

    DEVELOPMENT RIGHT

    For the Master Plan road

    network undertaken and

    developed: equivalent to 100

    % of built up area of such area

    surrendered

    17 GRANT OF TRANSFERABLE

    DEVELOPMENT RIGHT

    For the Master Plan Road /

    Road Development Plan

    undertaken and

    developed: equivalent to

    200% of built up area of

    such area surrendered.

    The M.C. G.V.M.C. has stated

    that it has become very difficult

    to them to acquire properties

    free of cost for formation of

    BRTS corridor hence requested

    to give more incentives to

    encourage the acquisition of

    lands for BRTS and other major

    road widening without paying

    any compensation.

    12 10.12 of

    G.O. 302

    13.4 of

    G.O.569

    TECHNICAL CLEARANCE FROM

    COMPETENT AUTHORITY

    24 HIGH RISE BUILDING

    COMMITTEE

    High Rise Building Committees

    are specified for HMDA & UDAs

    also.

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    67/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    13 10.12 of

    G.O. 302

    13.4 of

    G.O.569

    TECHNICAL CLEARANCE FROM

    COMPETENT AUTHORITY

    24 HIGH RISE BUILDING

    COMMITTEE

    High Rise Building Committees

    are specified for HMDA & UDAs

    also.

    14 As per Building Rules the

    permission is valid for 3yeards

    subject to conditions that the

    construction shall be

    commenced with in 1 year

    19(d) BUILDING PERMIT /

    LICENSE FEES

    The permission is valid for

    5years in case of High Rise

    Buildings & GroupDevelopment Schemes and

    3years in case of Non High

    Rise Buildings subject to

    condition that the

    construction shall be

    commenced with in

    18months. The permission

    can be revalidated foranother 2years on

    payment of building

    permit fee

    It is observed that the

    construction of High Rise

    Building is taking more than 3

    years period and

    representations have beenreceived by Govt. for extension

    of validity period.

    The building permission validity

    period is enhanced for High

    Rise Buildings and Group

    Development Schemes up to 5

    years

    COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86, 678,302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-2012)

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    68/69

    SL.NORULE NO /

    G.O.Ms.No.PROVISION

    MODIFIED

    RULE NOMODIFICATION REMARKS

    15 21 of

    G.O.86,678 &

    302

    22 of G.O.

    569

    OCCUPANCY

    CERTIFICATE

    Parameters

    (a) Number of

    floors

    (b) External

    setbacks

    (c) Parking space

    provision

    (d) Abuttingroad width

    26 (b) OCCUPANCY CERTIFICATE

    Parameters

    *No. of Floors

    External setbacks

    Usage of the building

    Parking space provision

    Abutting road width

    * The total height of the

    building may vary to a

    maximum of 1m with no

    change in the permitted

    number of floors subject to

    compliance of fire service

    norms

    Use of the building also made mandatory for

    issue of occupancy certificate as it is observed

    that after obtaining approval for residential

    buildings are being converted for commercial

    uses, schools, colleges etc.. which the not

    permissible in certain locations and which

    require more parking area, NOC from Fire

    Services Dept. and many other conditions.

    Further with reference to height also the

    deviations up to 1m subject to Fire Services

    norms are prescribed which will facilitate to

    obtain Occupancy Certificate depending on

    the ground condition.

  • 8/10/2019 AP_Building_Rules-2012_13_04_2012

    69/69