    Name of Item: Variable Capacitance type Level Indicator

    Specification:

    Electronic Level Transmitter:Service: Water

    Measuring Principle: Capacitance type

    Range: 0500 mm WC

    Accuracy: +/- 3 %

    Output: 4-20 mA DC

    Probe: fully insulated rod probe with preamplifier

    Mounted on probe head generates RF signal and converts detected capacitance signal to current Signal.

    Sump Tank:

    Service : Water

    Capacity : 80 liters

    MOC : SS-304Pump:

    Voltage : 220 V AC

    Power : HP

    Measuring Tank:

    Service : Water

    Capacity : 30 liters

    MOC : Transparent Acrylic

    Range : 0500 mm WC

    Necessary piping and fittings should be provided.

    The setup should be mounted on MS structure having good quality paint.

  • 7/25/2019 aocp spec

    2/11

    Name of Item:RTD Resistance-bulb Wheatstone Bridge Thermometers

    Specification:

    Resistance Bulb Thermometer: Pt

    100Accuracy: Class A

    Insulation: Mineral insulated

    Terminal Block: 4 wire termination in ceramic terminal

    Block provided in cast Aluminium Block

    Length: 200 mm

    The construction drawing, Temperature Vs Resistance Table & calibration Checking procedure along with

    portable wheatstone bridge (having inbuilt Galvanometer & battery) to measure resistance of Resistance

    Bulb Thermometer having measurement accuracy + 0.075 %.

    Portable Wheatstnebridge

    This set should be designed to provide an accurate and sensitive instrument of resistance and locating

    faults in cables by adopting the Varley Loop Circuit for tests. This set should be entirely self-contained witha dry battery and a Galvanometer. The instrument should be equipped with another switch controlling the

    sensitivity or short-circuiting the galvanometer. Arrangement should be provided to use the extra

    galvanometer or high source voltage for increasing the sensitivity of the bridge.

    Range: 0.001 ohm to 11, 11 megohms.

    Series Arm: Four decades in steps of thousands, tens and units ohms using manganian coil which can be

    used as a series resistance box also with + 0.1% accuracy

    Ratio Arms: The ratio arm of bridge are to be capable of selecting

    multiplying factors of 0.001, 0.01, 1, 10, 100 and 1000 for

    conductive resistance measurements and for varley loop test

    Null Detector

    Galvanometer: Ri 20 ohms, 1mm/ A sensitivityBattaery: 3 cell of 1.5 V, R 20 size

  • 7/25/2019 aocp spec

    3/11

    Name of Item: Apparatus for determination of flash point

    Specification:

    This apparatus is made as per IP 34, ASTMD-93 and IS 1448 (Part I) 1270 (P.21) and IS 1209-1953 methodB. It is used for finding out flash point above 70C and below 300C. The instrument having oil test jet/Gas

    test jet flame device, stirrer with flexible shaft. The assembly rests in air bath which is covered with dome

    shape metal top. The cup is fitted with insulated handle and locking Arrangement near cup flange. The

    assemble is kept on round shape electric heater with separate temp. Regulator.

    Suitable for operation on 220 volts 50 cycles Ac circuits.

    P.M. flash point apparatus electric heated with energy regulator oil test jet.

  • 7/25/2019 aocp spec

    4/11

    Name of Item:Sparkler Filters

    Specification:

    Sparkler Filters Zero Hold up models in M.O.C. SS-304, 316, 316L and optional with PP, halar,PTFE (PFA), PVDF coating/lining on all wetted parts. 8, 14, 18, 24 and 33 sizes with n no. of

    plates. Complete filtrations of batch without any holdup of unfiltered liquid. GMP model with

    complete unit mounted on SS trolley. Back wash facility for cleaning the filter without opening the

    assembly. SS 304 Jacket for hot filtration, Flameproof Motor, Sight Glass on outlet offered on

    request. Ideal for filtration in sugar, beverage, pharmaceuticals, chemicals, dyes, edible and non-

    edible oils, resins, paints, perfumes, activated carbonetc. The cake, filter aid and solids remain

    totally enclosed allowing filtration of toxic, hazardous and explosive liquids. The top dome

    structure ensures fast and easy removal of cartridge assembly and cleaning of cake.

  • 7/25/2019 aocp spec

    5/11

    Name of Item:Leaf Filters

    Specification:

    Pressure Leaf Filters 1-100m2 filtration area offered in vertical and horizontal models. Stainlesssteel filter elements, hence no repetitive cost, washing and maintenance of filter cloth. Filtration

    rates are 2-3 times higher on same filter area of plate and frame type filter. Automatic cake

    discharge with mechanical or pneumatic vibrator and optional spray nozzle for wet cake discharge.

    Ideal replacement for plate and frame filter. Closed system, no maintenance due to SS filtration

    mesh, low retention of oil, less occupancy of space etc. Very low % of unfiltered liquid retention in

    cake. Simple and economical bottom opening with 100% opening and optional butterfly valve for

    vertical PLF Closed pressurized operating system hence no spillage and loss of liquid, which helps

    in handling volatile / inflammable liquids and clean working environment. Pressure leaf filter can

    be completely automated with no human intervention.

  • 7/25/2019 aocp spec

    6/11

    Name of Item:Apparatus for determine Frictional losses in straight pipe, pipe fitting

    Specification:

    RANGE OF EXPERIMENT:-To determine the friction factor (major losses) for Darcy Weisbach equation.

    SPECIFICATION:- Block Type Acrylic Differential Manometer (250-0-250 mm) Flow control valve to change Discharge. Two Pipes (Length of pipe between two pressure tapings 1 mtr.)

    A. Dia. of pipe - 0.022 m (For pipe )B. Dia. of pipe - 0.016 m (For pipe )

    Transparent pizometer tube with scale to measuremeasuring tank discharge. Measuring tank- 295 X 345 X 345 mm Sump tank- 900 X 350 X 350 mm Greaves motor for recalculating type unit.- 0.5H.P. Self-Priming Stop clock.

    SERVICE REQUIRED:- Suitable Water supply. Suitable floor space to mount apparatus. 15 amps Single Phase Electrical Connection.

  • 7/25/2019 aocp spec

    7/11

    Name of Item:Evaporator rising falling film evaporator

    Specification:

    Stainless steel industrial vapor liquid separator.

    Shell is rated for vacuum 400 F. Vapor liquid separator has a 50" straight side, an 18"

    cone, and a 22" diameter.

    Separator has a 4" diameter flanged liquid discharge, a 10" diameter flanged steam inlet,

    and a 6" diameter flanged steam outlet.

    The separator has a 16" diameter hatch with a 6" diameter sight glass on the side and a 6"

    diameter sight glass on top.

    The flange on the top sight glass is broken and the hinge to top opening is bent

    Name of Item:Triple effect evaporator

    Specification:

    Tech Data:

    Three-effect falling film evaporator

    Rated evaporation: 50L / h

    Installed power: ~ 6,05KW

    feed temperature: room temperature, the material temperature

  • 7/25/2019 aocp spec

    8/11

    Name of Item:Sieve plate distillation column.

    Specification:

    Materialstainless steel 304

    TemperatureRoom temp~260(Electric heating included)

    Column sizeDN50*1200mm

    InternalsSieve tray columns.

    Reboiler10L or 20L

    Receiversize&quantity

    10L*2

    Condenser HTA

    0.86 (m2)

    Vacuity

    MIN:10mbar(depend on the nature of material and vacuum pump& vacuum pump not included)

    Floor arealength*width*height=1000*800*2700 (mm)(without vacuum pump)

    Power

    4KW (without pump)

    Estimated Cost:Prepared By:

  • 7/25/2019 aocp spec

    9/11

    Name of Item:Batch type tank crystallizer

    Specification:

    The setup consists of an open, jacketed and conical bottom vessel fitted with a low RPM

    agitator and a heater. Arrangement for Cooling water circulation and flow measurement in

    jacket is made by using storage type water tank, a pump and a rotameter.

    The feed/mother liquor is prepared in the crystallizer vessel itself using heater and stirrer.

    The hot super saturation solution in the crystallizer is then cooled by circulation of cooling

    water and crystals are formed. Necessary instrumentation is done for temp measurement

    Features

    Superb Painted structure

    Simple to operate & maintain

    Compact & stand alone set up

    Utilities Required

    Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper

    earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with

    switch for heater

  • 7/25/2019 aocp spec

    10/11

    Name of Item:Mechanical seal (multiple spring)

    Specification:

    Specifications:

    Shaft diameter: 1/2" to 6"

    Pressure Unbalanced: Vacuum to 10 bar

    Pressure Balanced: Vacuum to 35 bar

    Speed: Up to 2900 rpm

    Temperature: -50 oC to + 300 oC

  • 7/25/2019 aocp spec

    11/11

    Name of Item:pump cut model

    Specification:

    Specifications:

    Sectioning of an actual ANSI pump. (A Goulds-brand pump is used in the circumstance).

    Cleaning, priming and painting using a high-durability urethane coating.

    Color-coding of cutaway surfaces, seat and closurel elements, impeller and exterior

    surfaces using contrasting colors.

    Replacement, plated hardware, where necessary.

    All gaskets, seals and bearings visible.

    7-Gauge, formed-steel, powder-coated, baseplate, with provision for tabletop mounting andmounting on related workstation and storage products.

    Crating for shipment via motor freight.