antigen and antibody reactions agglutination tests
DESCRIPTION
Antigen and Antibody Reactions Agglutination TestsTRANSCRIPT
Dr.T.V.Rao MD 1
Antigen and Antibody Reactions
Agglutination Tests Dr.T.V.Rao MD
Dr.T.V.Rao MD 2
DIRECT AGGLUTINATION-Test patient serum against large, cellular
antigens to screen for the presence of antibodies.
• Antigen is naturally present on the surface of the cells.
• In this case, the Ag-Ab reaction forms an agglutination, which is directly visible.
Dr.T.V.Rao MD 3
Slide Agglutination Test• Used for serotyping (e.g. Salmonella)• Antigen: isolated Salmonella in suspension• Antibody: specific antisera against Salmonella• Place test Salmonella in a drop of saline on a
slide • Add a drop of antiserum, mix and rock slide
for approx 1 minute• Examine for agglutination
Dr.T.V.Rao MD 4
Slide Agglutination Test
Dr.T.V.Rao MD 5
Agglutination Test
Dr.T.V.Rao MD 6
OTHER DIRECT AGGLUTINATIONTESTS
• The particle antigen may be a bacterium.e.g.: Serotyping of E. coli, Salmonella using a
specific antiserum• The particle antigen may be a parasite.e.g.: Serodiagnosis of Toxoplasmosis• The particle antigen may be a red blood cell.e.g.: Determination of blood groups
Introduction:• The complement fixation test (CFT) was extensively
used in syphilis serology after being introduced by Wasserman in 1909.
• Complement is a protein (globulin) present in normal serum.
• Whole complement system is made up of nine components: C1 to C9
• Complement proteins are heat labile and are destroyed by heating at 56°C for 20 – 30 minutes.
• Complement binds to Ag-Ab complex• When the Ag is an RBC it causes lysis of RBC’s.
Principle• Complement takes part in many of the immunological reactions.
It gets absorbed during the combination of antigens and antibody.
• This property of antigen–antibody complex to fix the complement is used in complement fixation test for the identification of specific antibodies.
• The haemolytic system containing sheep erythrocytes (RBC) and its corresponding antibody (amboceptor) is used as an indicator which shows the utilization or availability of the complement.
• If the complement is fixed then there will be no lysis of sheep erythrocytes, thus denoting a positive test.
• If the complement is available then there will be haemolysis which is a property of complement, denoting a negative test.
Complement fixation (CF) • Antibody and antigen allowed to combine in
presence of complement • If complement is fixed by specific antigen-antibody
reaction, it will be unable to combine with indicator system
• Precautions• Serum must be heat-activated • Stored serum becomes anti-complementary • Extensive QC/standardization required • Only use for IgM antibodies
Components of CFTTest System• Antigen: It may be soluble or particulate.• Antibody: Human serum (May or may not contain Antibody
towards specific Antigen)
• Complement: It is pooled serum obtained from 4 to 5 guinea pigs. It should be fresh or specially preserved as the complement activity is heat labile (stored at -30 °C in small fractions). The complement activity should be initially standardized before using in the test.
Indicator System (Haemolytic system)• Erythrocytes: Sheep RBC• Amboceptor (Hemolysin): Rabbit antibody to sheep red cells
prepared by inoculating sheep erythrocytes into rabbit under standard immunization protocol.
Positive Test• Step 1:
At 37°CAntigen + Antibody + Complement Complement gets fixed
(from serum) 1 Hour
• Step 2:
At 37°CFixed Complement complex + Haemolytic system No Haemolysis
1 Hour (Test Positive)
Negative Test Step 1:
At 37°CAntigen + Antibody absent + Complement Complement not fixed
1 Hour
Step 2:
At 37°CFree Complement + Haemolytic system Haemolysis
1 Hour (Test Negative)
Results and Interpretations:• No haemolysis is considered as a positive test. • haemolysis of erythrocytes indicative of a negative test.
1 2 3 4
A
B
• Microtiter plate showing Haemolysis (Well A3, A3 and B4) and No Haemolysis (Well
Dr.T.V.Rao MD 14
Quantitative Micro Hemagglutination Test (HA)Haemagglutination Tests
(HA)
Dr.T.V.Rao MD 15
HEMAGGLUTINATION• Detects antibody to erythrocyte antigens
– sufficient concentration of antibody present-> antibody cross-link= agglutination
– non-reactive/insufficient antibody present= no agglutination
• Binding different antigens on the RBC surface = detect antibodies to antigen other than those present in the cells
Dr.T.V.Rao MD 16
Haemagglutination
RBC
Dr.T.V.Rao MD 17
Viral Haemagglutination• Some viruses and microbes contain proteins which
bind to erythrocytes (red blood cells) causing them to clump together
• NDV• Adenovirus III• AIV• IBV• Mycoplasma
Dr.T.V.Rao MD 18
HEMAGGLUTINATION INHIBITION TEST (HI)
VIRUSE SERUM
19
In the absence of anti-virus antibodies
Erythrocytes
VirusVirus agglutination of erythrocytes
Dr.T.V.Rao MD
20
In the presence of anti-virus antibodies
Erythrocytes
Virus Anti-virus antibodies
Viruses unable to bind tothe erythrocytes
Dr.T.V.Rao MD
Dr.T.V.Rao MD 21
Dr.T.V.Rao MD 22
Heterophile Agglutination Tests
• Weil – Felix Test or Reaction in Serodiagnosis of typhus fevers is heterophile agglutination test and sharing of common antigen between typhus Rickettsiae and some strains of Proteus bacilli
Dr.T.V.Rao MD 23
Other tests• Red cells as antigens • 1 Paul Bunnell test • 2 Cold agglutination test
Dr.T.V.Rao MD 24
Paul Bunnell test • Based on the principle of
presence of sheep agglutinins in the sera of infectious mononucleosis patents who are absorbed by OX red cells but not by guinea pig kidney extract
Dr.T.V.Rao MD 25
Cold Agglutination test• Positive in
Mycoplasma ( Primary Atypical ) Pneumonia
• The patients sera agglutinated human O group erythrocytes at 4 o c the agglutination being reversible at 37 0 c
Dr.T.V.Rao MD 26
Coombs (Antiglobulin)Tests
• Applications–Detection of
anti-Rh Ab–Autoimmune
hemolytic anemia
Dr.T.V.Rao MD 27
Dr.T.V.Rao MD 28
Coombs (Antiglobulin)Tests • Incomplete Ab• Direct Coombs Test– Detects antibodies on erythrocytes
+ ↔
Patient’s RBCs Coombs Reagent(Antiglobulin)
Dr.T.V.Rao MD 29
Coombs (Antiglobulin)Tests • Indirect Coombs Test
– Detects anti-erythrocyte antibodies in serum
Patient’s Serum
TargetRBCs
+ ↔Step 1
+ ↔Coombs Reagent
(Antiglobulin)
Step 2
Dr.T.V.Rao MD 30
Dr.T.V.Rao MD 31
Passive Agglutination• An agglutination reaction that employs
particles that are coated with antigens not normally found in the cell surfaces
• Particle carriers include:– Red blood cells– Polystyrene latex– Bentonite– charcoal
Dr.T.V.Rao MD 32
Passive Agglutination• Passive agglutination has been used
in the detection of :–Rheumatoid factor–Antinuclear antibody in LE–Ab to group A streptococcus antigens–Ab to Trichinella spiralis
Dr.T.V.Rao MD 33
Reverse Passive Agglutination•Antibody rather than antigen is attached to a carrier
particle• For the detection of microbial antigens such as:▫Group A and B streptococcus▫Staphylococcus aureus▫Neisseria meningitidis▫Haemophilus influenzae▫Rotavirus▫Cryptococcus neoformans▫Mycoplasma pneumoniae▫Candida albicans
Dr.T.V.Rao MD 34
Coagglutination• Name given to systems using inert
bacteria as the inert particles to which the antibody is attached
• S.aureus: most frequently used because it has protein A in its outer surface that naturally adsorbs the Fc portion of the antibody
Dr.T.V.Rao MD 35
• Highly specific but not very sensitive in detecting small quantities of antigen
Dr.T.V.Rao MD 36
False-Positive Result
• If injected with hCG to trigger ovulation or to lengthen luteal phase of menstrual cycle.
• Chorioepithelioma, hydatidiform mole or ingestion of aspirin
• To detect the presence of a testicular tumor in men
False Negative• Testing before reaching detectable levels of
hCG.
Dr.T.V.Rao MD 37
Immunofluorescence
• Antibodies can be labeled with fluorescent dye Can localize binding sites on cell
• Dyes: Fluorescein, rhodamine, phycoerythrin can be conjugated to Fc region of Ab (so antigen binding is unaffected
• Absorb at one wavelength and emit at another
Dr.T.V.Rao MD 38
Antigens on Cells or on Tissue Sections
UV Light
Fluorescence
Dr.T.V.Rao MD 39
Fluorescence Double layer Sandwich
UV Light
Antigens
Dr.T.V.Rao MD 40
Enzyme Immunoassay ( EIA )
• Introduced in 1966 alternative to fluorescent methods
• Versatile, simple economical• Absence of radiation.• EIA means measuring enzymes
labelled antigen, hapten, antibody
Dr.T.V.Rao MD 41
Ag
Peroxidase Enzyme is permanently attached to Antibody Probe
Microtiter ELISAAntigens are immobilized to the plastic surface of a
Microtiter Plate
Enzyme Linked Immuno-Sorbant Assay
ELISA
Ag
Substrate that turns from clear to green
Dr.T.V.Rao MD 42
Ag
Peroxidase Enzyme is permanently attached to the Antibody Probe
Microtiter ELISAAntigens are immobilized to the plastic surface of a
Microtiter Plate
Enzyme Linked Immuno-Sorbant Assay
ELISA
Ag
Substrate that turns from clear
to green
Dr.T.V.Rao MD 43
ELISA• The ELISA (Enzyme-Linked Immuno-
Sorbant Assay) can be used both qualitatively and quantitatively to measure antigen-antibody binding. Depending on what variation you use, it will detect antigen (hormones, enzymes, microbial antigens, illicit drugs) or antibody (anti-HIV in the screening test for HIV infection) in body fluids or tissue culture supernatants.
Dr.T.V.Rao MD 44
ELISA• Enzyme-Linked Immuno-Sorbant
Assay, also called ELISA, Enzyme ImmunoAssay or EIA, is a biochemical technique used mainly in immunology to detect the presence of an antibody or an antigen in a sample. The ELISA has been used as a diagnostic tool in medicine and plant pathology, as well as a quality control check in various industries.
Dr.T.V.Rao MD 45
Enzyme Linked Immuno Assay• The Technique
involves use of Immuno-Sorbant and absorbing material specific for one of the components of reaction, the antigen or antibody
Dr.T.V.Rao MD 46
Components in ELISA testing
• Conjugate – Horseradish peroxidase
• Substrate - O-phenyle diamine dihydrochloride
• The test is conducted in solid phase Polystyrene, Polyvinyl or polycarbonate tubes or in plastics
Dr.T.V.Rao MD 47
ELISA plate
Dr.T.V.Rao MD 48
ELISA methodology• Performing an ELISA involves at least one
antibody with specificity for a particular antigen. The sample with an unknown amount of antigen is immobilized on a solid support (usually a polystyrene microtiter plate) either non-specifically (via adsorption to the surface) or specifically (via capture by another antibody specific to the same antigen, in a "sandwich" ELISA).
Dr.T.V.Rao MD 49
ELISA methodology• After the antigen is immobilized the
detection antibody is added, forming a complex with the antigen. The detection antibody can be covalently linked to an enzyme, or can itself be detected by a secondary antibody which is linked to an enzyme through bioconjugation
Dr.T.V.Rao MD 50
Sandwich ELISA
Dr.T.V.Rao MD 51
Different methods of ELISA
• Direct and Indirect ELISA
• Sandwich• Non
competitive Sandwich
Dr.T.V.Rao MD 52
ELISA – most popularly used method• The ELISA is probably the most commonly
used immunological assay because of its versatility, sensitivity (ability to detect small amounts of antigen or antibody), specificity (ability to discriminate between closely related but antigenically different molecules), and ease of automation. Although some of the substrates are carcinogenic, they are generally considered safer than radioisotopes used in RIA (radioimmunoassay).
Dr.T.V.Rao MD 53
Uses of ELISA• Helps detection of
Antigens, Antibodies, hormones and Enzymes
• Eg in Microbiology Antigens – HbS Ag Antibodies HIV, HCV,
CMV, several other disease
Dr.T.V.Rao MD 54
Radio Immuno AssayBerson and Yallow
• Besides fluorescent dyes other labels can be used
• Uses with Radio isotopes • Variety of tests are done for detection of
antigen or antibody• The term binder ligand assay has been used• The minute amounts of substances can be
detected• Used in Biology and Medicine
Dr.T.V.Rao MD 55
Rosalyn S. Yalow and Sol Berson
Dr.T.V.Rao MD 56
RIA ( Radio Immuno Assay )• The technique was
introduced in 1960 by Berson and Yalow as an assay for the concentration of insulin in plasma. It represented the first time that hormone levels in the blood could be detected by an in vitro assay.
Dr.T.V.Rao MD 57
Uses of RIA• Used for detection of Hormones,
enzymes,tumour markers• IgE and viral antigens• RIA is a competitive binding assay fixed
amount of antibody and radiolabelled antigen react in the presence of unlabelled antigen
• Detection is done for free and bound fractions, ratios calculated
Dr.T.V.Rao MD 58
Immunofluorescence• The purpose of
immunofluorescence is to detect the location and relative abundance of any protein for which you have an antibody. Once you have antibodies to your favourite protein, you can use them to indicate where the protein is located.
Dr.T.V.Rao MD 59
Immunofluorescence
Dr.T.V.Rao MD 60
Fluorescent Methods
Dr.T.V.Rao MD 61
Direct and Indirect Methods
Dr.T.V.Rao MD 62
Western Blot• Western blot analysis can detect your protein
of interest from a mixture of a great number of proteins. Western blotting can give you information about the size of your protein (with comparison to a size marker or ladder in kDa), and also give you information on protein expression (with comparison to a control such as untreated sample or another cell type or tissue).
Dr.T.V.Rao MD 63
Western Blot Test• The method originated from the
laboratory of George Stark at Stanford. The name western blot was given to the technique by W. Neal Burnette and is a play on the name Southern blot, a technique for DNA detection developed earlier by Edwin Southern. Detection of RNA is termed northern blotting.
Dr.T.V.Rao MD 64
Appearance of test readings
Dr.T.V.Rao MD 65
Flowcytometry
• FACS- fluorescence-activated cell sorter Analyze cell populations
• Sort cells with different features into different containers (e.g., T and B cells; cells that are producing a cell-surface marker from those that are not)
Dr.T.V.Rao MD 66
Dr.T.V.Rao MD 67
Uses for flow cytometry
• Percentage of a total population of cells• Measuring antigen density within a
population of cells • Multiple antibodies can be used to
assess several cell surface antigens simultaneously
• Clinical analysis (tumor characterization)
Dr.T.V.Rao MD 68
Chemiluminescence's• Chemiluminescence's Chemical reaction
emitting energy in the form of light• Chemilumiscence - Luminol or acridinium
esters causes signal in the process of antigen antibody reaction
• Signal can be amplified, measured, and the concentration of the analyses sample
• Uses the automated methods.• Increasingly used where the volume of work is
large
Dr.T.V.Rao MD 69
Chemiluminescence's Immuno Assay
Dr.T.V.Rao MD 70
Immunochromatographic Tests
• One step in diagnosing• Simple Economical.• Reliable• Eg HbsAg A small cassette system containing a
membrane impregnated with antiHbsAg antibody colloidal gold dye conjugate
The membrane is exposed at three windows on the cassette
Dr.T.V.Rao MD 71
Immunochromatographic Tests
Immunochromatographic Tests
• A colored band appears at the second window
• Control also can be recorded
Dr.T.V.Rao MD 72
Also called as Dot Methods• The tests can be done by
paramedical staff, as they are simple to read
• Helps in emergency rooms.
• The results are available within few minutes
• The HIV and HBV infections can be done at the earliest
Dr.T.V.Rao MD 73
• Programme Created by Dr.T.V.Rao MD for Medical and Paramedical Students in
the Developing world • Email