2
ANTI VIBRATION SOLUTIONS FOR WIND TURBINES Scanvib Engineering ApS Sdr. Kajgade 1-5 • DK – 8500 Grenaa • Denmark Tel +45 87 680 600 • Fax +45 87 680 601 • E-mail: [email protected] Scanvib Engineering ApS Sdr. Kajgade 1-5 DK – 8500 Grenaa Denmark Tel +45 87 680 600 Fax +45 87 680 601 E-mail: [email protected] Gear bushings Generator supports Nacelle supports Turbine Type Quantity per turbine Quantity per turbine Quantity per turbine NEG Micon (Vestas) NM 600 600 kW 2 NM 750 750 kW 2 4 NM 900 900 kW 2 4 NM 1000 1.0 MW 2 4 4 NM 1500 1.5 MW 4* 4 NM 2000 2.0 MW 4* 4 NM 2750 2.75 MW 2 NORDTANK (Vestas) NTK 500 500 kW 2 NTK 600 600 kW 2 NTK 1500 1.5 MW 2 Nordex N 43 600 kW 2 Suzlon 1.25 MW 4 4 SÜDWIND (Nordex) S46 600 kW 2 TACKE (GE) TW 600 a, e 600 kW 2 TURBOWINDS T 600-48 600 kW 2 WINCON W 600/45 600 kW 4 4 (height adjustable) W 750/48 750 kW 2 * in some turbines also as split type bushings Scanvib Engineering ApS Sdr. Kajgade 1-5 DK – 8500 Grenaa D nmark Tel +45 87 680 600 Fax +45 87 680 601 E-mail: [email protected] Geear bushings Generator supports Nacelle supports Turbine Type Quantity per turbine Quantity per turbine Quantity per turbine Wind World (Vestas) W-2800 150 kW 5 W-2920 250 kW 4 W-3700 500 kW 4 W-4200 600 kW 4 W-5200 750 kW 4 e

Upload: others

Post on 15-Apr-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ANTI VIBRATION SOLUTIONS

ANTI VIBRATION SOLUTIONS FOR

WIND TURBINES

Scanvib Engineering ApSSdr. Kajgade 1-5 • DK – 8500 Grenaa • Denmark

Tel +45 87 680 600 • Fax +45 87 680 601 • E-mail: [email protected]

Scan

vib

Eng

inee

ring

ApS

Sdr.

Kaj

gade

1-5

DK

–85

00G

rena

a

Den

mar

k

Tel+

4587

680

600

Fax

+45

8768

060

1

E-m

ail:

scan

vib@

scan

vib.

dk

Gear

bu

sh

ing

sG

en

era

tor

su

pp

ort

sN

acell

esu

pp

ort

s

Turb

ine

Type

Quantity

per

turb

ine

Quantity

per

turb

ine

Quantity

per

turb

ine

NEG

Mic

on(V

esta

s)

NM

600

600

kW2

NM

750

750

kW2

4N

M90

090

0kW

24

NM

1000

1.0

MW

24

4N

M15

001.

5M

W4*

4N

M20

002.

0M

W4*

4N

M27

502.

75M

W2

NO

RD

TAN

K(V

esta

s)

NTK

500

500

kW2

NTK

600

600

kW2

NTK

1500

1.5

MW

2

Nor

dex

N43

600

kW2

Suzl

on1.

25M

W4

4

SÜD

WIN

D(N

orde

x)

S46

600

kW2

TAC

KE

(GE)

TW60

0a,

e60

0kW

2

TUR

BO

WIN

DS

T60

0-48

600

kW2

WIN

CO

NW

600/

4560

0kW

44

(hei

ghta

djus

tabl

e)

W75

0/48

750

kW2

*in

som

etu

rbin

esal

soas

split

type

bush

ings

Scan

vib

Eng

inee

ring

ApS

Sdr.

Kaj

gade

1-5

DK

–85

00G

rena

a

Dnm

ark

Tel+

4587

680

600

Fax

+45

8768

060

1

E-m

ail:

scan

vib@

scan

vib.

dk

Geear

bu

sh

ing

sG

en

erato

rsu

pp

orts

Nacell

esu

pp

orts

Turb

ine

Type

Quantity

per

turb

ine

Quantity

per

turb

ine

Quantity

per

turb

ine

Win

dW

orld

(Ves

tas)

W-2

800

150

kW5

W-2

920

250

kW4

W-3

700

500

kW4

W-4

200

600

kW4

W-5

200

750

kW4

e

Page 2: ANTI VIBRATION SOLUTIONS

Anti vibration solutions for windturbines

All Scanvib products are designed by Scanvib based upon the original engineering data for each wind-turbine.

Our anti-vibration products will not only fit into your turbine. They are simply the original product designed and supplied to major wind turbine builders. You will get the components that has been designed, tested and approved for each turbine.

Gear bushingsLarge range of Scanvib gearstay bushings originally designed by us and supplied to world leading turbine manufacturers.

Many different designs available with original turbine specific characteristics for optimum gear protection, low noise and long life.

For turbines in kW to multi-MW sizes.

Generator and nacelle mountsVibration and noise minimising rubber mounts desig-ned by Scanvib and supplied to many world leading turbine manufacturers.

Many different designs available with original turbine specific characteristics for optimum service life and low noise.

For turbines in kW to multi-MW sizes.

Generator mounts are available with optional height adjustment for easy installation and alignment between gearbox and generator.

We supply components for the following turbine makes:

• Bonus / Siemens Windpower• Windworld• Nordex• Made

• NEG-Micon / Micon / Nordtank• Tacke / GE• Suzlon• Gamesa

Sdr. Kajgade 1-5, 8500 Grenaa •Tel +45 87 680 600 • Fax +45 87 680 601 • E-mail: [email protected] • www.scanvib.dk

Scanvib Engineering ApS

Worldwide export to OEM and aftermarket clients

Scan

vib

Eng

inee

ring

ApS

Sdr.

Kaj

gade

1-5

DK

–85

00G

rena

a

Den

mar

k

Tel+

4587

680

600

Fax

+45

8768

060

1

E-m

ail:

scan

vib@

scan

vib.

dk

Rub

berb

ushi

ngs

and

supp

orts

forw

ind

turb

ines

PS.:

For

som

ew

ind

turb

ines

we

als

osupply

gear

sta

yblo

cks

and

shaft

s.

The

gear

sta

yblo

cks

for

som

etu

rbin

es

are

supplied

as

easy-e

xchange

split-

type

blo

cks

(e.g

.N

EG

Mic

on

1.5

MW

/2.0

and

Sie

mens

1.3

MW

).

Gear

bu

sh

ing

sG

en

era

tor

su

pp

ort

sN

acell

esu

pp

ort

s

Turb

ine

Type

Quantity

per

turb

ine

Quantity

per

turb

ine

Quantity

per

turb

ine

Acow

ind

1.0

MW

4B

azan

600

kW2

4 2AN

Bon

us(S

iem

ens

Win

dPo

wer

)

Kom

bi30

0kW

24

450

kW2

42

Mk

III60

0kW

2M

kIV

600

kW2

44

1.0

MW

4fro

nt2

back

21.

3M

W4 4*

front

2ba

ck2

Upg

rade

1:1.

3M

W4*

42.

0M

W4*

back

22.

3M

W4*

Bra

nden

burg

erW

ind

Uni

on(R

Epow

er)

BWU

48-7

50kW

2

Des

arol

los

700

kW2

*in

som

etu

rbin

esal

soas

split

type

bush

ings

Scan

vib

Eng

inee

ring

ApS

Sdr.

Kaj

gade

1-5

DK

–85

00G

rena

a

Den

mar

k

Tel+

4587

680

600

Fax

+45

8768

060

1

E-m

ail:

scan

vib@

scan

vib.

dk

Gear

bu

sh

ing

sG

en

erato

rsu

pp

orts

Nacell

esu

pp

orts

Turb

ine

Type

Quantity

per

turb

ine

Quantity

per

turb

ine

Quantity

per

turb

ine

Fris

iaF

48-6

00kW

2F

56-8

50kW

2

GET

41-6

00kW

22

4

Hus

umer

Schi

ffsw

erft

(REp

ower

)

HSW

600

kW2

Irabi

a1.

3M

W2

IZAR

600

kW2

1.3

MW

4Sp

litty

pe4

Lage

rwey

LW75

0kW

2

MAD

EAE

46/1

600

kW2

AE52

800

kW2

AE61

1.3

MW

2AE

902.

0M

W4

Mic

on(V

esta

s)

M53

0/2

725

0kW

24

6M

750

/31

400

kW2

48

M75

0/4

475

0kW

24

M15

00/4

2/44

600

kW2

28

M15

00/4

475

0kW

22

8M

1800

/48

600

kW2

2/4

8M

1800

/48

750

kW2

4