ANTI STATIC CLEAN ROOM FLOORING ESD Flooring Issues In Clean Rooms
![Page 2: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/2.jpg)
As electrostatic discharge (ESD) thresholds increase, awareness of ESD
standards and control in cleanrooms is a major concern.
ESD Floor
![Page 3: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/3.jpg)
Most polymer flooring materials are electrical insulators,
which can create static buildup.
ESD Floor
![Page 4: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/4.jpg)
Cleanroom floors are frequently found in
Electronics,
Pharmaceutical,
Biopharmaceutical,
Medical device industries,
Aerospace,
And other critical manufacturing environments.
Clean room flooring
![Page 5: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/5.jpg)
Anti Static and Conductive floors are designed to measure at or below
35 Million ohms.
Clean room flooring
![Page 6: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/6.jpg)
Typical contains from
500,000 to 1,000,000 particles
(0.5 microns or larger) per cubic foot of air.
Clean room flooring
![Page 7: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/7.jpg)
A Class 100 cleanroom is designed to never allow
more than 100 particles (0.5 microns or larger)
per cubic foot of air.
Clean room flooring
![Page 8: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/8.jpg)
Class 1000 and Class 10,000 cleanrooms are designed to limit particles to 1000 and
10,000 respectively
(In comparison, a human hair is about
75-100 microns in diameter).
Clean room flooring
![Page 9: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/9.jpg)
A particle 200 times smaller (0.5 micron) than the human hair
can cause major disaster in a cleanroom !
Clean room flooring
![Page 10: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/10.jpg)
Contamination can lead to expensive
downtime
and increased production costs.
Clean room flooring
![Page 11: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/11.jpg)
In fact,
the billion dollar NASA Hubble Space Telescope was damaged and did not perform as designed because of a particle smaller than 0.5 microns.
Clean room flooring
![Page 12: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/12.jpg)
ESA
is becoming more of a concern as static charges have been seen to actually bond contaminants to surfaces of products or tooling.
Clean room flooring
![Page 13: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/13.jpg)
Example:
for a 4” wafer, charged to 1000 volts, a particle of 1 micron in diameter would have the bonding force of over 830,000 pounds per square inch.
Clean room flooring
![Page 14: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/14.jpg)
Electrostatic attraction between charged objects and particles can be quite
strong compared to gravitational, aerodynamic, or
adhesion forces.
Clean room flooring
![Page 15: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/15.jpg)
Conductive work surfaces can be considered a current-carrying
hazard to people
and ESD-sensitive devices.
Clean room flooring
![Page 16: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/16.jpg)
ESD control measures traditionally have been required for:
• Defense, • Electronics assembly, • Wafer manufacturing, • Semiconductor, • & The disk drive industry.
Clean room flooring
![Page 17: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/17.jpg)
In the area of ESA control, these industries have ramped up ESA programs
for their cleanrooms:
• Fiber optics, • Medical, • Pharmaceutical, • Wafer, • And disk drive manufacturing.
Clean room flooring
![Page 18: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/18.jpg)
Controlling static electricity and ESD events in the cleanroom is important for these industries.
Clean room flooring
![Page 19: Anti static clean room flooring](https://reader033.vdocuments.us/reader033/viewer/2022052400/55a5dd111a28abe3398b46a9/html5/thumbnails/19.jpg)
ESD S20.20 recommends a
target RH between 30% – 70%.
< 30% RH, materials have a greater tendency
to charge.
Surface Resistance versus Relative Humidity (RH):