another quality building product adjustable direct fix furring … · 2018-02-01 · installation...

3
For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023 1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com Another Quality Building Product DSR_MBFR_MBF_27102015 Information contained within this document supersedes all previous versions and is subject to change without notice. Installation MBFR / MBF Adjustable Direct Fix Furring Channel Resilient Mount PRODUCT CODE: MBFR / MBF PUBLICATION DATE: October 2016 1/3 MBFR SPECIFICATIONS FURRING CHANNEL: MBF SPECIFICATIONS Installation Instructions Clip Height:1 3/8” Metal Thickness: .069” / 14 gauge Width: 1 1/4” Length: 4 7/8” Height Of Rubber: 3/8” *Height of rubber on top of clip Minimum: 25 Gauge with hemmed edge Depth: 7/8” or 1-1/2” Width at top: 1-1/4” Width flange to flange: 2-1/2” Clip Height: 1” Metal Thickness: .069”/14 Gauge Width: 1 1/4” Length: 4 7/8” 4 7/8” 3 ¼” 1” 3/8¼” 3 1/4" 1" 4 7/8" 1 1/8" 3 1/4" 2" 2" Part No. Description Length Stock Pack Appx LB/Ft. 25 Gauge (18 Mils) FC-7825 7/8” Furring Channel 12 500 0.2597 FC-11225 1-1/2” Furring Channel 12 500 0.3324 20 Gauge (30 Mils) FC-7820 7/8” Furring Channel 12 500 0.3659 FC-11220 1-1/2” Furring Channel 12 500 0.4723

Upload: others

Post on 13-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023

1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com

Another Quality Building Product

DS

R_M

BFR

_MB

F_27

1020

15

Information contained within this document supersedes all previous versions and is subject to change without notice.

Inst

alla

tion

MBFR / MBFAdjustable Direct Fix Furring Channel Resilient Mount

PRODUCT CODE: MBFR / MBFPUBLICATION DATE: October 2016

1/3

MBFR SPECIFICATIONS

FURRING CHANNEL:

MBF SPECIFICATIONS

Installation Instructions

Clip Height:1 3/8” Metal Thickness: .069” / 14 gauge Width: 1 1/4” Length: 4 7/8” Height Of Rubber: 3/8”*Height of rubber on top of clip

Minimum: 25 Gauge with hemmed edgeDepth: 7/8” or 1-1/2”Width at top: 1-1/4”Width flange to flange: 2-1/2”

Clip Height: 1”Metal Thickness: .069”/14 GaugeWidth: 1 1/4”Length: 4 7/8”

4 7⁄8”

3 ¼”

1”

3⁄8”

¼”

3 1/4"

1"

3/4"

3/8"

1"3/

8"

1/4"

4 7/8"

1 1/

8"

3 1/4"

4"

3 1/4"

1"

1"

4 7/8"

1 1/

8"

3 1/4"

2" 2"

Part No. Description Length Stock Pack Appx LB/Ft. 25 Gauge (18 Mils) FC-7825 7/8” Furring Channel 12 500 0.2597FC-11225 1-1/2” Furring Channel 12 500 0.3324 20 Gauge (30 Mils) FC-7820 7/8” Furring Channel 12 500 0.3659FC-11220 1-1/2” Furring Channel 12 500 0.4723

PRODUCT CODE: MBFR / MBFPUBLICATION DATE: October 2016

MBFR / MBF - Installation Instructions cont.

For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023

1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com

DS

R_M

BFR

_MB

F_27

1020

15

2/3

CEILING INSTALLATION GUIDE:

*Do NOT use the MBFR in a ceiling installation, MBF ONLY.

Step 1

Review layout guidelines before starting installation of walls or ceilings (see Page 6). We suggest installing the ceiling first, before installing the walls.

Step 2

Space Resilmount Betafix MBF so not to exceed 48” OC. Secure MBF with 2 fasteners in holes either side of the clip.Wood: Use #8 x 2-1/2” coarse thread screws

Steel: Use #8, #10, or #12 x 1-5/8” Type s Self tapping screws

Concrete: Use 3/16” x 2-1/4” Tapcon or equal anchor

Step 3

Snap hat channel into Resilmount Betafix MBF.

- If using above a 25 gauge furring channel, first slide the clips onto the furring channel, then attach to the ceiling.

WALL INSTALLATION GUIDE:

*For both the MBF and the MBFR.

Step 1Review layout guidelines before starting installation of walls or ceilings (see Page 6). We suggest installing the ceiling first, before installing the walls.

Step 2Space Resilmount Betafix MBF or MBFR so not to exceed 48” OC. Secure clips with a single fastener through the middle screw hole in the clip.

Wood: Use #8 x 2-1/2” coarse thread screws

Steel: Use #8, #10, or #12 x 1-5/8” Type s Self tapping screws

Concrete: Use 3/16” x 2-1/4” Tapcon or equal anchor

Step 3

Snap hat channel onto Resilmount clip.

Step 4The floor shims are critical to ensure best results. Place 1/4” shims on floor in front of sole plate. Install the first row of drywall vertically against the wall. Attach drywall to channel following local building codes.

Note: Only remove the shims after all the gypsum board is completely screwed to all furring channels.

Step 5Use acoustical caulk around the entire perimeter of each wall.

IMPORTANT NOTE:The Betafix MBFR is for wall assemblies only, use of the MBFR in a ceiling assembly is NOT permitted.

INSTALLATION NOTES- Resilmount Betafix MBF or MBFR shall not exceed 48” on center along furring channel.- Spacing between metal furring channels shall not exceed 24” - Fasten the Resilmount Betafix MBF and MBFR to the substrate with a fastener approved for a minimum pull-out and shear of 120 Lbs. - Locate the bottom row of Resilmount Betafix MBF and MBFR within 3” of the floor. (May be adjusted lower to accommodate installation of baseboard) - Metal furring channels are installed perpendicular to the joists or studs. - Install the drywall perpendicular to metal furring channel, leaving a 1/4” thick gap around perimeter of wall to be filled with acoustical caulk. Caulk around the entire perimeter of the gypsum board.

FASTENERSWood: # 8 x 2-1/2” Coarse Threads (A)

Steel: #8, #10 or #12 x 1-5/8” Self Tapping Type S (B)

Concrete: 3/16” x 2-1/4” Anchor Screws (C)

DO NOT fasten Resilmount clips to framing members with nails. Use only approved screws.

A

B

C

PRODUCT CODE: MBFR / MBFPUBLICATION DATE: October 2016

MBFR / MBF - Installation Instructions cont.

For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023

1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com

DS

R_M

BFR

_MB

F_27

1020

15

2/3

FIXING LAYOUT

Layouts for studs at 24” OC with 1 or 2 layers of Gypsum Board

Layouts for studs at 16” OC with 1 or 2 layers of Gypsum Board

A50R CLIPS AT 24" x 48"

6" 24"

48"

6"24

"

48"

CR CLIPS AT 16" x 48" OC

CR CLIPS AT 24" x 48" OC

6"16

"

48"

6"24

"

48"

A237R / MBF / MBFS CLIPS AT 24" x 48"

OC

24"

6"24

"

48"

A237R / MBF / MBFS CLIPS AT 16" x 48"

OC

16

A50R CLIPS AT 24" x 48"

6" 24"

48"

6"24

"

48"

CR CLIPS AT 16" x 48" OC

CR CLIPS AT 24" x 48" OC

6"16

"

48"

6"24

"

48"

A237R / MBF / MBFS CLIPS AT 24" x 48"

OC

24"

6"24

"

48"

A237R / MBF / MBFS CLIPS AT 16" x 48"

OC

16