annexin v-fitc apoptosis detection kit -...

1
Order & Inquiry Tel: (713)732-2181 Fax: +1-866-747-4781 E-mail: [email protected] Order & Inquiry Tel: +49-89-46148500 Fax: +49-89-461485022 E-mail: [email protected] Annexin V-FITC Apoptosis Detection Kit Description Annexin V-FITC kit provides a rapid and convenient assay for apoptosis. Annexin V-FITC kit detects the externalization of phosphatidylserine in apoptotic cells using recombinant annexin V conjugated to green-fluorescent fluorescein isothiocyante (FITC) dye and necrotic cells using propidium iodide (PI) by flow cytometry and fluorescence microscope. The AnnexinV-FITC kit uses annexin V conjugated with FITC to label phosphatidylserine sites on the membrane surface. The kit also includes propidium iodide (PI) stains necrotic cells with red fluorescence. After treatment with both probes, apoptotic cells show green fluorescence, dead cells show red and green fluorescence, and live cells show little or no fluorescence. As soon as possible, analyze the stained cells by flow cytometry, measuring the fluorescence emission at 530 nm (e.g., FL1) and >575 nm (e.g., FL3). The population should separate into three groups: live cells will show only a low level of fluorescence, apoptotic cells show green fluorescence and dead cells show both red and green fluorescence.Confirm the flow cytometry results by viewing the cells under a fluorescence microscope, using filters appropriate for fluorescein (FITC) and rhodamine (TRITC) or Texas RedR dye. Components Contents Cat#:B32115 Annexin V-FITC PI Staining Solution 1× Binding Buffer 250 μl 250 μl 25 ml Cat#:B32117 500 μl 500 μ 25 ml × 2 Storage Notice Store in refrigerator (2–8° C) and protect from light. Figure 2. Apoptosis of 3T3 cells induced by high dose of H2O2. Expected results Protocol Figure 1.Jurkat cells (T-cell leukemia, human) treated with 0, 4, 8, 16 ng/ml TNF for 24 hours. Cells were then treated with the reagents in the kit, followed by flow cytometric analysis. Note that the TNF-treated cells have a higher percentage of apoptotic cells than the basal level of apoptosis seen in the control cells. Please centrifuge before use ! Induce apoptosis in cells using the desired method. Prepare a negative control by incubating cells in the absence of inducing agent. Harvest the cells after the incubation period and wash in cold phosphate-buffered saline(PBS). Re-centrifuge the washed cells, discard the supernatant, and resuspend the cells in 100 μl 1 × Binding Buffer. Add 5 μL Annexin V -FITC and 5 μL PI Staining Solution to each 100 μL of cell suspension. Incubate the cells at room temperature for 15 minutes. After the incubation period, add 400 μL of 1 × Binding Buffer, mix gently and keep the samples on ice. 1. 2. 3. 4. 5. 6. 7.

Upload: others

Post on 15-Mar-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Order & InquiryTel: (713)732-2181 Fax: +1-866-747-4781E-mail: [email protected]

Order & InquiryTel: +49-89-46148500 Fax: +49-89-461485022E-mail: [email protected]

Annexin V-FITC Apoptosis Detection Kit

DescriptionAnnexin V-FITC kit provides a rapid and convenient assay for apoptosis. Annexin V-FITC kit detects the externalization of phosphatidylserine in apoptotic cells using recombinant annexin V conjugated to green-fluorescent fluorescein isothiocyante (FITC) dye and necrotic cells using propidium iodide (PI) by flow cytometry and fluorescence microscope. The AnnexinV-FITC kit uses annexin V conjugated with FITC to label phosphatidylserine sites on the membrane surface. The kit also includes propidium iodide (PI) stains necrotic cells with red fluorescence. After treatment with both probes, apoptotic cells show green fluorescence, dead cells show red and green fluorescence, and live cells show little or no fluorescence.

As soon as possible, analyze the stained cells by flow cytometry, measuring the fluorescence emission at 530 nm (e.g., FL1) and >575 nm (e.g., FL3). The population should separate into three groups: live cells will show only a low level of fluorescence, apoptotic cells show green fluorescence and dead cells show both red and green fluorescence.Confirm the flow cytometry results by viewing the cells under a fluorescence microscope, using filters appropriate for fluorescein (FITC) and rhodamine (TRITC) or Texas RedR dye.

Components

Contents Cat#:B32115

Annexin V-FITC

PI Staining Solution

1× Binding Buffer

250 µl

250 µl

25 ml

Cat#:B32117

500 µl

500 µ

25 ml × 2

Storage

Notice

Store in refrigerator (2–8° C) and protect from light.

Figure 2. Apoptosis of 3T3 cells induced by high dose of H2O2.

Expected results

Protocol

Figure 1.Jurkat cells (T-cell leukemia, human) treated with 0, 4, 8, 16 ng/ml TNF for 24 hours. Cells were then treated with the reagents in the kit, followed by flow cytometric analysis. Note that the TNF-treated cells have a higher percentage of apoptotic cells than the basal level of apoptosis seen in the control cells.

Please centrifuge before use !

Induce apoptosis in cells using the desired method. Prepare a negative control by incubating cells in the absence of inducing agent.Harvest the cells after the incubation period and wash in cold phosphate-buffered saline(PBS).Re-centrifuge the washed cells, discard the supernatant, and resuspend the cells in 100 µl 1 × Binding Buffer.Add 5 µL Annexin V -FITC and 5 µL PI Staining Solution to each 100 µL of cell suspension.Incubate the cells at room temperature for 15 minutes.After the incubation period, add 400 µL of 1 × Binding Buffer, mix gently and keep the samples on ice.

1.

2.

3.

4.

5.6.

7.