Testing laboratory for climatic, mechanical and corrosive environmental stress CERTIFICATE of QUALITY TEST Test report - No. 10142 / 13 Client ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Equipment under test Ethernet System type MSX-E3011 Quantity 1 system manufacturing date September 2013 Purpose Test of the dynamic-mechanical robustness, of the climatic resistance and oft the degree of protection IP65 according to the standards Test program Dry heat according to IEC 60068-2-2 Damp heat, cyclic according to IEC 60068-2-14 Vibration, sinusoidal according to IEC 60068-2-6 Degree of protection IP65 according to IEC 60529 Test period 30 September to 28 October 2013 Realization / results see page 2 to 6 Total number of pages 11 (incl. 3 appendices) Test result The test was realized according to the standards and to the demands of the client. The further evaluation will be done by the client. Dipl.-Ing. R. Lein Dipl.-Ing. (FH) G. Zieten head of test lab / test manager test engineer Berlin, 11 November 2013

Upload: others

Post on 23-Nov-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: and corrosive environmental stress CERTIFICATE of QUALITY …

Testing laboratory for climatic, mechanical and corrosive environmental stress

CERTIFICATE of QUALITY TEST

Test report - No. 10142 / 13

Client ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster

Equipment under test Ethernet System type MSX-E3011

Quantity 1 system

manufacturing date September 2013

Purpose Test of the dynamic-mechanical robustness, of the climatic resistance and oft the degree of protection IP65 according to the standards

Test program Dry heat according to IEC 60068-2-2 Damp heat, cyclic according to IEC 60068-2-14 Vibration, sinusoidal according to IEC 60068-2-6 Degree of protection IP65 according to IEC 60529

Test period 30 September to 28 October 2013

Realization / results see page 2 to 6

Total number of pages 11 (incl. 3 appendices)

Test result The test was realized according to the standards

and to the demands of the client.

The further evaluation will be done by the client.

Dipl.-Ing. R. Lein Dipl.-Ing. (FH) G. Zieten head of test lab / test manager test engineer

Berlin, 11 November 2013

Page 2: and corrosive environmental stress CERTIFICATE of QUALITY …

Test report-No. 10142 / 13 page 2 / 6 1 Purpose

Test of the dynamic-mechanical robustness, of the climatic resistance and oft the degree of protection IP65 of the MSX-E3011 under defined environmental conditions according to the standards.

2 Equipment under test (EUT)

Ethernet System type MSX-E3011 Quantity 1 system

system components type serial no. MSX-E3011-BD A-D 810759

CMX-21 A-D 461952 CMX-61 A-D 456269 CMX-80 A-D 389263, A-D 389267, A-D 389269, A-D 389277, A-D 389282, A-D 389287, A-D 389289, A-D 389290, A-D 414395, A-D 414396, A-D 428214, A-D 440373, A-D 414394, A-D 440397, A-D 447986

delivery date of the EUT 24 September 2013

3 Basics

3.1 Demands of the client

3.2 Used standards

IEC 60068-1:1988 + Corr. 1988 + A1:1992 DIN EN 60068-1:1995-03 „Environmental testing - Part 1: General and guidance“

IEC 60068-2-2:2007 DIN EN 60068-2-2; VDE 0468-2-2:2008-05 „Environmental testing - Part 2-2: Tests - Test B: Dry heat“

IEC 60068-2-6:2007 DIN EN 60068-2-6; VDE 0468-2-6:2008-10 „Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)“

IEC 60068-2-30:2005 DIN EN 60068-2-30:2006-06 „Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)“

IEC 60068-2-47:2005 DIN EN 60068-2-47:2006-03 „Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests“

IEC 60529:1989 + A1:1999 DIN EN 60529; VDE 0470-1:2000-09 „Degrees of protection provided by enclosures (IP code)“

Page 3: and corrosive environmental stress CERTIFICATE of QUALITY …

Test report-No. 10142 / 13 page 3 / 6 4 Test program

4.1 Dry heat - Test B according to IEC 60068-2-2 as well as to the demands of the client

EUT Ethernet System MSX-E3011 operating

test temperature (+55 ± 2)°C test duration 4 d

relative humidity each < 50 %

4.2 Damp heat, cyclic - Test Db according to IEC 60068-2-30 as well as to the demands of the client

EUT Ethernet System MSX-E3011 operating during 2nd cycle lower test temperature (+25 2)°C relative humidity (95 3) % upper test temperature (+40 2)°C relative humidity (93 3) % dwell time each 9 h rate of temperature change each 3 h (0.17 K/min) test duration 48 h (2 cycles, each 24 h)

4.3 Vibration, sinusoidal at standard conditions - Test Fc according to IEC 60068-2-6 as well as to the demands of the client

EUT Ethernet System MSX-E3011 not operating

frequency range 10 - 55 Hz amplitude 15 mm (2 g) sweep rate 1 octave/min number of axes 3 test duration 2:15 h (10 cycles per axis / 3 x 0:45 h)

Visual inspection (according to paragraphs 4.1 to 4.3) The sample was inspected before and after each individual test, for the presence of cracks, distortions, breaks, thermal damages and any other changes.

Functional test (according to paragraphs 4.1 to 4.3) Before and after each single test as well as during the tests with operating specimen, a functional test will be performed according to the demands of the client. For this purpose the sample will be connected to a voltage of 24 VDC and to a notebook. The status LED and the software status will be checked.

4.4 Degrees of protection IP6X (protection against access to hazardous parts) according to the IEC 60529 § 13.2 as well as to the demands of the client

EUT Ethernet System MSX-E3011, not operating EUT position general purpose, horizontal

Before the dust test, the protection against access to hazardous parts IP6X shall be verified using a standardized wire. The access probe 1.0 mm (force 1 N) must not penetrate the housing at any point.

Page 4: and corrosive environmental stress CERTIFICATE of QUALITY …

Test report-No. 10142 / 13 page 4 / 6 4.5 Protection against solid foreign objects IP6X (dust tight)

according to the IEC 60529 § 13.4 as well as to the demands of the client

EUT Ethernet System MSX-E3011, not operating EUT position general purpose, horizontal

The certification of the degrees of protection IP6X is to be carried out in compliance with the specifications of the standards. The specimen will be placed inside the dust chamber within a whirling air flow with finely distributed dust. For the test IP6X with vacuum, a suction hose must be led to the inside of the samples. Using vacuum a volume of 80X the volume of the specimen will be removed without exceeding a flow-rate of 60 Volumes per hour. Under no circumstance may the vacuum exceed 2kPa. Once a flow-rate of 40-60 Volumes/h has been achieved, the test will last at least 2h.

Talcum powder will be used as test dust (composition and grain size distribution in compliance with the regulation).

Visual inspection After the dust test IP6X, the sample will be examined for external damage and any other alterations. The housing of the sample will be opened and examined for penetrated dust after the test IPX5.

4.6 Protection against water jets IPX5 according to the IEC 60529 § 14.2.5 as well as to the demands of the client

For the certification of the degrees of protection IPX5 the following specifications of the standard apply:

EUT Ethernet System MSX-E3011, not operating EUT position general purpose, horizontal

test set-up water jets from a standardized jet nozzle with 6.3 mm inner diameter water flow rate 12.5 l/min 5 % water pressure proportional to the specified water flow rate water temperature must differ by no more than 5 K to that of the samples clearance approx. 2.5 m (jet nozzle to housing) duration at least 3 min

Visual inspection After the water jet test IPX5 the sample will be examined for external damage and any other alterations. In the subsequent visual inspection of the opened sample, it will be examined whether water or dust can penetrate inside the sample.

Functional test (according to paragraphs 4.4 to 4.6) Before and after the tests a functional test shall be performed according to the demands of the client. For this purpose the samples will be connected to a voltage of 24 VDC and to a notebook. The status LED and the software status will be checked.

Page 5: and corrosive environmental stress CERTIFICATE of QUALITY …

Test report-No. 10142 / 13 page 5 / 6 5 Realization

The environmental tests were carried out one by one according to the program of testing methods (complex 4.1 to 4.6) according to the standards and to the demands of the client.

Visual inspections Before and after each single test, the MSX-E3011 were examined visually for external damages and any other changes. After the test IPX5 a visual inspection of the opened sample, was examined whether water or dust can penetrate inside the sample.

Functional tests Before and after each single test as well as during the tests with operating specimen, a functional test was performed according to the demands of the client. For this purpose the sample was connected to a voltage of 24 VDC and to a notebook. The status LED and the software status was checked.

Fastening of the specimen During the vibration test (complex 4.3), the specimen was mounted to an aluminum plate with 35 mm rail mount. This plate with the specimen was directly installed in the respective axis on the vibration table, see pictures appendix 2.

Measuring and test equipment temperature chamber 21 WS 115 (SN: 03-45654, Binder) climatic chamber VCS³ 4034 (SN: 58679984850010, Vötsch) shaker S55240/LS-340 (SN: 226/12, TIRA) acceleration sensor 752-500 (SN: 12858, Endevco) acceleration sensor 352C22 (SN: 119770, PCB) rigid IEC steel wire P 10.27 (SN: 5011594, PTL) infrared thermometer Fluke 561 (SN: 14950036, Fluke) jet nozzle SD 6,3 (Gödel) pump evm 5-16n5 (SN: CN5230021, Ebara) dust chamber 24 SK 160 (Aucoteam) turntable IPXX (SN: -, Gödel) power supply DC HCS-3302 (SN: G281000752, Manson) notebook 2GHz, 2 GB (SN: 282009515001365, Sony)

Page 6: and corrosive environmental stress CERTIFICATE of QUALITY …

Test report-No. 10142 / 13 page 6 / 6 6 Results

6.1 Climatic tests (according to paragraphs 4.1 and 4.2)

During the environmental tests of the MSX-E3011 with

- dry heat (+ 55°C, 4 d) - test B - damp heat, cyclic (25°C/95 % r.h. and 55°C/93 % r.h.) - test Db

neither environmental nor corrosive defects were detected. The operability was ensured before, partially during and after the environmental tests.

6.2 Dynamic-mechanical test (according to paragraph 4.3)

During and after the dynamic-mechanical tests of the MSX-E3011 with

- vibration, sinusoidal - test Fc (10 – 55 Hz, 15 mm / 2g, 3 x 0:45 h)

no external damages were determined at the specimen. The operability was ensured before and after the test.

6.3 Tests for degree of protection (according to paragraphs 4.4 and 4.6)

The tests for the certification of the degrees of protection for the MSX-E3011 with

- protection against access to hazardous parts - test IP6X - protection against solid foreign objects - test IP6X - protection against water jets - test IPX5

neither mechanical damages nor any other changes of the specimen were determined.

Protection against access to hazardous parts IP6X

The standardized test wire (Ø 1 mm, force 1 N) could not penetrate into the housing.

During the following functional test, the operability was ensured.

Protection against solid foreign objects IP6X (dust tight)

After the test no traces of dust were detected inside the housing.

During the following functional test, the operability was ensured.

Protection against water jets IPX5

After the test no traces of water were detected inside the housing.

During the following functional test, the operability was ensured.

The test was realized according to the standards and to the demands of the client.

The further evaluation will be done by the client.

The results of the test only refer to the above mentioned equipment under test. The report or individual pages of this test report may only be copied following the written consent of the test laboratory. The test report-No. 10142 / 13 includes 6 pages and appendix 1 to 3.

appendix 1 – climatic protocols appendix 2 – protocols of the vibration test appendix 3 – pictures

Page 7: and corrosive environmental stress CERTIFICATE of QUALITY …

Appendix 1 to test report-No. 10142 / 13 page 1 / 1

0

10

20

30

40

50

60

70

80

90

100

30.09.13 12:00 01.10.13 00:00 01.10.13 12:00 02.10.13 00:00 02.10.13 12:00 03.10.13 00:00 03.10.13 12:00 04.10.13 00:00 04.10.13 12:00 05.10.13 00:00

tem

pera

ture

[°C

]

date / time Temperature behavior of test chamber WS21 during test with dry heat ( +55°C / 4 d), according to complex 4.1

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

08.10.13 12:00 09.10.13 00:00 09.10.13 12:00 10.10.13 00:00 10.10.13 12:00 11.10.13 00:00

hum

idity

[%]

tem

pera

ture

[°C]

date / time

Temperature and humidity behavior of climatic test chamber VCS³ during test with damp heat, cyclic (+25°C / +55°C / 95 % r.h. (2 cycles / each 24 h)), according to complex 4.2

Page 8: and corrosive environmental stress CERTIFICATE of QUALITY …

Appendix 2 to test report-No. 10142 / 13 page 1 / 1

Vibration, sinusoidal, x-axis, 10 - 55 Hz, ± 0,15 mm / 2 g

Vibration, sinusoidal, y-axis, 10 - 55 Hz, ± 0,15 mm / 2 g

Vibration, sinusoidal, z-axis, 10 - 55 Hz, ± 0,15 mm / 2 g

Page 9: and corrosive environmental stress CERTIFICATE of QUALITY …

Anlage 3 zum Pb-Nr. 10142 / 13 Seite 1 / 3 Pictures

Picture 1 Picture 2 Ethernet System MSX-E3011 Ethernet System MSX-E3011 before all tests in the climatic test chamber WS 21 before the climatic test dry heat

Picture 3 Picture 4 Ethernet System MSX-E3011 Ethernet System MSX-E3011 in the climatic test chamber with test equipment in the climatic test chamber VCS³ 4034 before the climatic test damp heat, cyclic before the climatic test damp heat, cyclic

Picture 5 Picture 6 Ethernet System MSX-E3011 on the Ethernet System MSX-E3011 on the vibration test facility S55240 vibration table with acceleration sensors before the vibration test in x-axis before the vibration test in x-axis

Page 10: and corrosive environmental stress CERTIFICATE of QUALITY …

Anlage 3 zum Pb-Nr. 10142 / 13 Seite 2 / 3

Picture 7 Picture 8 Ethernet System MSX-E3011 on the Ethernet System MSX-E3011 on the vibration test facility S55240 vibration table with acceleration sensors before the vibration test in y-axis before the vibration test in y-axis

Picture 9 Picture 10 Ethernet System MSX-E3011 on the Ethernet System MSX-E3011 on the vibration test facility S55240 vibration table with acceleration sensors before the vibration test in z-axis before the vibration test in z-axis

picture11 picture 12 Ethernet System MSX-E3011 Ethernet System MSX-E3011 with standardized test wire (Ø 1 mm, force 1 N) with standardized test wire (Ø 1 mm, force 1 N) before the protection against hazardous parts IP6X during the protection against hazardous parts IP6X

Page 11: and corrosive environmental stress CERTIFICATE of QUALITY …

Anlage 3 zum Pb-Nr. 10142 / 13 Seite 3 / 3

picture 13 picture 14 Ethernet System MSX-E3011 Ethernet System MSX-E3011 in the dust chamber SK160 in the dust chamber SK160 before the protection against solid foreign objects IP6X after the protection against solid foreign objects IP6X

picture 15 picture 16 Ethernet System MSX-E3011 Ethernet System MSX-E3011 on the turn table with standardized water jet on the turn table with standardized water jet during the protection against water jets IPX5 during the protection against water jets IPX5

picture 17 picture 18 Ethernet System MSX-E3011 Ethernet System MSX-E3011 without detectable traces of dust and water without detectable traces of dust and water after the protection against water jets IPX5 after the protection against water jets IPX5