ancon 500 tension systems

16
Ancon 500 Tension Systems for the Construction Industry CI/SfB Xt6 March 2008

Upload: others

Post on 12-Sep-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ancon 500 Tension Systems

Ancon 500Tension Systemsfor the Construction Industry

CI/SfB Xt6

March 2008

Page 2: Ancon 500 Tension Systems

2

Page 3: Ancon 500 Tension Systems

Ancon designs and manufactures high integrity steel products for

the construction industry. Through continuous programmes of

new product development, inward investment and employee

advancement, the company is committed to maintaining the

highest level of customer service within a dynamic and

challenging industry.

Tie bars are increasingly being used instructures and buildings as an architectural aswell as a structural element.

In addition to providing a high load capacity,the Ancon 500 Tension System meets thedemanding aesthetic requirements of today’sapplications.

Masonry Support Systems

Masonry Reinforcement

Windposts and Lintels

Wall Ties and Restraint Fixings

Channel and Bolt Fixings

Tension Systems

Stainless Steel Fabrications

Flooring and Formed Sections

Shear Load Connectors

Reinforcing Bar Couplers

Reinforcement Continuity Systems

Punching Shear Reinforcement

Insulated Balcony Connectors

Refractory Fixings

3

Ancon Tension Systems 4

Carbon Steel Systems 4

Stainless Steel Systems 5

Ancon Compression Systems 5

System Components 6-7

Applications 8-9

Performance and Dimensions 10-12

Connecting Plates 13

Specifying and Ordering 13

Installation Guidance 14-15

Other Ancon Products 15

ISO 9001: 2000FM 12226

ISO 14001: 2004EMS 505377

Page 4: Ancon 500 Tension Systems

Tension Systems

Ancon 500 System Carbon Steel The carbon steel Ancon 500 System is suitablefor most applications requiring a cost-effectivesolution. Bars are available in nine diametersfrom 8mm to 42mm. Performance details areshown on page 10. Bars are either untreated,zinc plated or hot-dipped galvanised and areavailable in most sizes up to 6 metres in length.The availability of each size of bar is given onpage 11. The system can be extended over themaximum bar length by the inclusion ofcouplers or anchor discs. All fork connectorsare zinc plated as standard to provide a basicresistance to corrosion. The fork connectorsand couplers are designed to allowadjustments to be made to the system lengthwithout the need for turnbuckles.

Other finishes, in addition to those mentionedabove, are available on request. Carbon steelsystems can be supplied painted to customerrequirements.

Ancon 360 System Carbon Steel The Ancon 360 System is available in two sizesfor applications requiring a bar diameter above42mm. This carbon steel system extends theAncon range to 56mm and a capacity of844kN. Similar in appearance to the Ancon500, this system uses bar with a minimum yieldstrength of 360N/mm2. All technical details forthe Ancon 360, including performance details,dimensions and the available lengths of eachsize of bar are shown adjacent to the Ancon500 on pages 10 and 11.

THE ANCON 500 SYSTEM● High load capacity

● Carbon steel or stainless steel

● Bars from 8mm to 42mm diameter

● Choice of finishes

● Aesthetically designed forks

● Locking nut included as standard

● Full adjustment within fork connectors

● Visual check of correct installation

● Isolation supplied as standard withstainless steel systems

ANCON TENSION SYSTEMSThe use of new materials and formingprocesses have enabled cast components tobe produced which are not only functional,strong and durable, but also aestheticallypleasing. Ancon Tension Systems comprise arange of components that can be used tocreate a variety of assemblies, from simple tiebars to complex bracing systems involvingseveral bars joined at one point. Unlikestandard tie bars that require turnbuckles,adjustment to the length is accommodatedwithin the fork connectors.

ApprovalsAncon Tension Systems are covered by twoapprovals, the European Technical Approval(ETA-06/0146) and the German DIBt ApprovalNo. Z-14.4-470 (sizes 8 - 56).

Ancon 500 SystemThe Ancon 500 Tension System combinesaesthetic appearance with high performance.It is available in various sizes from 8mm to42mm in both carbon steel and stainless steel.

All components of the system can be suppliedin a variety of finishes to provide corrosionresistance and to meet the demandingaesthetic requirements of many architecturalapplications. The bar used in this system has aminimum yield of 500N/mm2.

4

Page 5: Ancon 500 Tension Systems

Electro-polishedstainless steel forkand locking nut withbright drawn bar

Satin-polished stainlesssteel fork and locking nutwith bright drawn bar

Ancon 500 System Stainless SteelThe stainless steel Ancon 500 System isrecommended for applications that demandcorrosion resistance and a maintenance-freelife, or where an attractive, polished finish isrequired. Stainless steel bars in nine diameterscan be supplied, in most cases, in lengths upto 6 metres. Performance details are shown onpage 10 and the availability of each size of baris given on page 11. The system can beextended over the maximum bar length by theinclusion of couplers or anchor discs. The forkconnectors and couplers are designed to allowadjustments to be made to the system lengthwithout the need for turnbuckles.

Hand polished stainlesssteel fork, locking nut and bar

Surface finish is usually an important factor inapplications using stainless steel. Ancon barsare bright drawn as standard but can be handpolished if required. The stainless steel forksand locking nuts can be supplied electro-polished, satin-polished or hand polished. Thephotographs below provide a good indicationof the available finishes; actual finishes maydiffer slightly. Couplers and anchor discs aresupplied with a smooth machined finish asstandard, and can be satin-polished or handpolished when required. All available finishesand order codes are shown on page 13.

Isolation SystemIsolation material is supplied as standard withthe stainless steel system to enable its fixingto a connecting plate of a dissimilar metal.Each stainless steel fork connector is suppliedwith two clear, self-adhesive, PET (polyester)washers to be applied around the fixing holeeither side of the structure. Stainless steel pinsfeature a PTFE coating around the barrel.

Ancon Compression SystemsTo complement the Tension System range,Ancon designs and manufacturesCompression Systems. These systemscomprise high strength tubes, forkconnectors and locking nuts and areavailable in both carbon and stainless steelin a variety of sizes and finishes. For moreinformation please contact Ancon.

5

Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Page 6: Ancon 500 Tension Systems

Tension Systems

SYSTEM COMPONENTSThe wide range of components available canbe used to create a variety of assemblies, fromsimple tie bars to complex bracing systemsinvolving several bars joined at one point.

Fork Connectors & Locking NutsAncon fork connectors are supplied with alocking nut which provides a neat transitionfrom bar to fork. Forks and their locking nutshave left or right hand threads, and aresupplied complete with a pin. They arestamped with the size and either the letter R or L to identify the hand of the thread.

The locking nuts firmly lock the bar to the forkand ensure that the connection remainssecure. The internally threaded section of thelocking nut is recessed to allow the threadedend of the bar to be hidden when theinstallation is complete.

Adjustments to the length of the system canstill be made after installation without aturnbuckle, by loosening the locking nut androtating the bar. The extent of this adjustmentdepends on the size of the bar, but will rangefrom ±9mm for an Ancon 500/8 to ±45mm foran Ancon 360/56.

Carbon steel forks and locking nuts arezinc plated as standard. Stainless steel forksand locking nuts are electro-polished asstandard and can also be supplied satin orhand polished.

Pin Fork connector

PTFE coating(stainless steelsystem only)

Anchor Disc

Locking nut

Each stainless steel fork is supplied with twoclear, self-adhesive, PET (polyester) washers toisolate the system from a connecting plate of adissimilar metal.

PinsThe pins are a two-part construction and onceinstalled are flush with the fork. The installationrequires a twin-pin driver. Two driver bits of theappropriate size are supplied with each Anconsystem. This type of fixing, known as ‘SnakeEyes’*, allows a high torque to be achievedwithout damage to the pin.

The female section of the pin is locatedthrough the fork connector and temporarilyheld in position. A second driver is then usedto wind the male section into position creatinga secure connection.

Stainless steel pins are supplied with a PTFEcoating around the barrel, as illustrated, toisolate the system from a connecting plate of adissimilar metal.

Anchor DiscsAnchor discs allow up to eight bars to beconnected together. They can be used at thecentre of conventional cross bracing, or whereseveral bars need to be connected at onepoint. Anchor discs are machined from plateand can be supplied satin or hand polished tomatch the system. Ancon can design andmanufacture plates in special shapes toreplace standard anchor discs and suit theaesthetic requirements of an application.

6 *‘Snake Eyes’ is the registered trademark of Tamperproof Screw Company Inc.

Page 7: Ancon 500 Tension Systems

Tie BarsTie bars have a right-hand thread at one endand a left-hand thread at the other. Flats arepressed into the bar close to each end. Theseallow the bar to be screwed into the forkconnectors and adjustments to be made atany time after assembly. Neither couplers norturnbuckles will be required for applicationsusing a single bar between two forks. The baris correctly installed when all threads arehidden within the locking nut.

The availability of each size of bar is given on page 11. All bars are cut to a tolerance of±2mm of the specified length.

Carbon steel bars are available either untreated,zinc plated or hot-dipped galvanised. Stainlesssteel bars are bright drawn as standard orhand polished when required.

Compression SystemsAncon designs and manufactures CompressionSystems, which comprise high strength tubes,fork connectors and locking nuts. For moreinformation please contact Ancon.

CouplersCouplers have right and left hand threads andare used in applications where more than onebar is required between forks. They aresupplied with a locking nut for each end of thecoupler. Adjustments to the length of thesystem can still be made after installation, byloosening the locking nut and rotating the bar.

Couplers are machined from bar and can havethe provision for a hanger to be fitted to limitthe deflection of bars of 16mm diameter orgreater. If a hanger is required a lug is weldedto the coupler. Stainless steel couplers canbe supplied with a polished finish to matchthe system.

Zinc plated bar

Hot-dipped galvanised bar

Bright drawn bar

Hand polished bar

Machined coupler

Coupler with hanger to limit thedeflection of long tension bars

Untreated bar

7

Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Page 8: Ancon 500 Tension Systems

Tension Systems

APPLICATIONSAncon has supplied Tension Systems to manystructures and buildings. The wide range ofcomponents can be used to create a variety ofassemblies, from simple tie bars to complexbracing systems involving several bars joinedat one point. The following applicationsdemonstrate the variety of uses.

Timber ConstructionA combination of timber and steel can use the best properties of each material andachieve a cost-effective and attractive design.Ancon Tension Systems can be connected tothe timber compression members, and if highloads are involved, several bars can be usedtogether.

CanopiesCanopies are frequently supported from aboveto provide unobstructed access below. Ancontension bars transfer the load from the front ofthe canopy back to the main structure or to amast for free standing canopies.

Roof StructuresTrusses and lattice frames which support roofscan benefit from the replacement of tensionmembers with the Ancon system. This willallow generous site adjustments to be made to accommodate inaccuracies within theframe. This would not be possible with aconventionally bolted frame.

8

Page 9: Ancon 500 Tension Systems

Stainless Steel Tension SystemsStainless steel is used for applications where a maintenance-free life is important or where a high quality polished finish is required. This can be particularly impressive when used inconjunction with large areas of glazing.

Cross-BracingThe use of anchor discs in cross-bracedpanels will allow bars to lie in the same plane.This removes the need to offset bars, with thedisc providing an interesting design feature forthe panel.

Glazed StructuresThe passage of light is normally a vitalconsideration in the design of glazed structures.

The small profile of the Ancon Tension Systemensures the maximum transmission of light. Inglazed structures, the aesthetically designedAncon system will be highly visible, enhancingthe overall appearance of the structure.

9

Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Page 10: Ancon 500 Tension Systems

Tension Systems

500 System 360 SystemThread Size 8 10 12 16 20 24 30 36 42 48 56

Failure Loads (kN) 22.5 37.5 54.5 102 159 229 364 531 728 760 1055Yield Loads (kN) 17 29 42 71 110 156 247 408 551 510 710Design Capacities (kN) 18 30 43 81 127 183 291 424 582 608 844

PERFORMANCE AND DIMENSIONSThe yield loads indicated below are based onrigorous tests. The design capacities include amaterial factor (γm) of 1.25 against failure. Anappropriate partial safety factor (γf) will need tobe applied to the characteristic dead, imposedand wind loads.

Forks must be correctly aligned, and positionedin the same plane to ensure that bending is notintroduced into the tension system.

Ancon 500 & 360 Carbon Steel System

Thread Size 8 10 12 16 20 24 30 36 42

Failure Loads (kN) 22.5 37.5 54.5 102 159 229 364 531 728Yield Loads (kN) 17 29 42 71 110 156 247 408 551Design Capacities (kN) 18 30 43 81 127 183 291 424 582

Ancon 500 Stainless Steel System

500 System 360 SystemThread Size 8 10 12 16 20 24 30 36 42 48 56

Bar Diameter 8 10 12 16 20 24/25 30 35 42/40 45 55Fork Length l 40 49 60 78 94 115 140 169 196 224 261Fork Diameter w 23.5 29 35 48 60 70 89 106 123 140 164Plate Thickness p 8 10 12 16 20 22 30 30 35 40 50Pin to End r 10.5 13.5 16 22 28 33 41 50 58 66 77Pin to Plate Edge t 12 15 18 23 29 35 43 54 63 74 83Hole Diameter for Pin h 7.5 9.5 11.5 14.5 18.5 21.5 26.5 30.5 35.5 42.5 50.5Pin Length g 23 28.5 34 46 58 68 86 103 118 135 156Adjustment a 9 10 13 15 16 22 25 28 30 35 45Thickness of Flat f 6 8 10 14 18 21 27 32 36 41 50Position of Flat e 17 20 25 38 43 58 69 84 99 116 139Pin to Bar End x 19 23 27 35.5 42 52 62.5 76 89 102.5 116.5Length of Locking Nut n 18 22 27 33 38 49 60 71 84 93 108

Notes: The bar diameter of Ancon 500/24 is 24mm in Stainless Steel and 25mm in Carbon Steel. The bar diameter of Ancon 500/42 is 42mm in Stainless Steel and 40mm in Carbon Steel.Ancon 360 Systems are only available in Carbon Steel.

Dimensions of Fork Connectors (mm)

l n e

fBar diameter

w

g p

r t

h

a= =x

10

✗Fork ends of the tension system must

be positioned in the same plane

✓Design Example

Characteristic dead load = 30.0kN γf = 1.4

Characteristic imposed load = 22.6kN γf = 1.6

Design load = (30.0 x 1.4) + (22.6 x 1.6) = 78.2kN

Use Ancon 500/16

Design capacity = 81kN > 78.2kN

Ancon Tension Systems are not suitable fordynamic loads.

Page 11: Ancon 500 Tension Systems

Component Bar Fork Connector & Locking Nut Pin

Thread Size 8 10 12-20 24-30 36-42 8-12 16-42 8-42UTS (Rm) N/mm2 620 650 850 700 650 510 400 520Yield or 0.2% Proof Stress (Rp) N/mm2 470 500 780 550 500 355 250 225Elongation % 40 40 20 20 20 25 25 40Material Reference 1.4401/4 1.4401/4 1.4462 1.4462 1.4462 1.4462 1.4462 1.4401/4

500 System 360 SystemThread Size 8 10 12 16 20 24 30 36 42 48 56

Connector Length c 38 45 56 83 82 104 125 144.5 166.5 189 226Connector Diameter d 17 21 25 35 43 52 65 78 90 103 121Adjustment a 9 10 13 15 16 22 25 28 30 35 45Bar Length Correction b 8 9.5 11.5 21 17 22 26 29 34 39 45.5Length of Locking Nut n 18 22 27 33 38 49 60 71 84 93 108Hanger Bar Diameter – – – 8 8 8 10 10 10 12 12Hole Position m – – – 33.0 37.0 49.0 59.1 74.5 93.1 103.2 123.4Spanner Size (mm A/F) s 13 17 19 30 36 46 55 65 75 85 95

Note: Ancon 360 Systems are only available in Carbon Steel.

Dimensions of Couplers (mm)

500 System 360 SystemThread Size 8 10 12 16 20 24 30 36 42 48 56

Untreated 3 3 3 6 6 6 6 6 6 6 6Zinc Plated 8 to 25µm 3 3 3 6 6 6 6 6 6 2.5 2.5

Hot-dipped galvanised 60 to 150µm 3 3 3 6 6 6 6 6 6 6 6Stainless Steel 3 3 6 6 6 6 6 6 6 - -

Note: Material in excess of these maximum lengths can be sourced to meet special project requirements. Contact Ancon for more information.

Maximum Available Bar Lengths (metres)

c c

m

dd

Coupler with hanger Machined coupler

Minimum Material Specification for Carbon Steel System

Minimum Material Specification for Stainless Steel System

11

Component Bar Fork Connector & Locking Nut Pin

Thread Size 8-42 48-56 8-12 16-56 8-56UTS (Rm) N/mm2 650 520 510 400 610Yield or 0.2% Proof Stress (Rp) N/mm2 500 360 355 250 350Elongation % 16 16 20 20 14Material Reference 080M40* 080M40 1.0570 1.0570 1.1191

*Selected certified material

Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Thread Size

Right and left hand threads inall couplers

a

n

==b

s

c

Page 12: Ancon 500 Tension Systems

500 System 360 SystemThread Size 8 10 12 16 20 24 30 36 42 48 56

Disc Thickness p 8 10 12 16 20 22 30 30 35 40 50Overall Diameter k 100 123 148 196 242 282 355 425.5 493.5 563 654Effective Diameter j 76 93 112 150 184 212 269 318 367 416 488Hole Diameter for Pin h 7.5 9.5 11.5 14.5 18.5 21.5 26.5 30.5 35.5 42.5 50.5

Note: Ancon 360 Systems are only available in Carbon Steel.

Dimensions of Anchor Discs (mm)

j

h

k

Min 40˚

p

ANCHOR DISCS

Anchor discwith four bars

Anchor discwith three bars

Special anchor plate with three bars

Tension Systems

12

Special RequirementsAncon can design and manufacture plates inspecial shapes to replace standard anchordiscs and suit the aesthetic requirements ofany application.

Page 13: Ancon 500 Tension Systems

Length 1 Length 2

Coupler with hanger

Coupler without hanger

xx

System length

For dimension x see fork connector details on page 10.

Bar length

500 System 360 SystemThread Size 8 10 12 16 20 24 30 36 42 48 56

Plate Thickness p 8 10 12 16 20 22 30 30 35 40 50Hole Diameter h 7.5 9.5 11.5 14.5 18.5 21.5 26.5 30.5 35.5 42.5 50.5Position of Hole t 12 15 18 23 29 35 43 54 63 74 83

Note: Ancon 360 Systems are only available in Carbon Steel.

Dimensions of Connecting Plates (mm)

3t

t

3t

h

θ

Platethickness p

4.2t

2.5t

θ

t

SPECIFYING AND ORDERINGAncon Tension Systems are supplied as fullsystems and are not available as individualcomponents.

System lengths are measured between thecentres of the pins in the forks. The maximumbar lengths are shown in the table on page 11and should be considered when determiningthe system length.

Zinc coating (8 to 25µm) to bars will providesome protection against corrosion, but is onlyintended to be used for systems which areinternal installations. Hot-dipped galvanising(60 to 150µm) will provide greater protectionbut should be considered as only part of theoverall protection treatment. Stainless steelaffords the greatest protection and does notrequire any further treatment.

The Ancon Tension System can be specifiedas follows: System / size / system length /material / finish.

A fully polished Ancon 500 stainless steelsystem using 16mm diameter bar, 2750mmbetween the pins would be specified as:-Ancon 500/16/2750/SS/6. The material andfinish codes are from the adjacent table.

Surface FinishCode Material Bar Fork & Nut Coupler Disc

CS/1 Carbon Untreated Zinc plated Zinc plated UntreatedCS/2 Carbon Zinc plated Zinc plated Zinc plated Zinc platedCS/3 Carbon Hot-dipped galvanised Zinc plated Zinc plated Hot-dipped galvanisedSS/4 Stainless Bright Drawn Electro-polished Machined MachinedSS/5 Stainless Bright Drawn Satin-polished Satin-polished Satin-polishedSS/6 Stainless Hand polished Hand polished Hand polished Hand polished

Material and Finish Codes

t

tt

t

t

t

13

Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

CONNECTING PLATESConnecting plates should be designed to suiteach application. The critical dimensions areprovided in the table and diagrams. In theexamples shown here θ is 45˚. These platesshould be manufactured from either gradeS355 carbon steel or grade 1.4462 stainlesssteel; users should consider the corrosionproperties of the material selected. Isolationmaterial is supplied as standard with thestainless steel tension system to enable itsfixing to a connecting plate of a dissimilarmetal.

Notes: This table includes Ancon's standard finishes. Other finishes are available on request. Carbon steel systemscan be supplied painted to customer requirements.

Note: Connecting plates can bemanufactured by Ancon on request.

Page 14: Ancon 500 Tension Systems

Tension Systems

INSTALLATION GUIDANCEIt is important to follow Ancon's installationinstructions, supplied with each system, toensure that the Tension System meets theperformance criteria.

The locking nuts should be fully screwed ontothe bar at each end and the bar screwed intothe forks using an open ended spanner of thecorrect size. When the requiredsystem length is reached, thelocking nuts must be turned back to the fork and tightenedusing soft touch pliers for Ancon 500/8 to 12 or a hook spanner for Ancon 500/16 and above and the Ancon 360 System.

When the installation is complete, all threadsmust be hidden within the locking nut. If thethread is visible, the bar is not sufficientlyengaged in the fork and would need to beadjusted.

Each fork is supplied with a locking nut and pin to enable fixing to a connecting plate oranchor disc.

14

Incorrect installation

Correct installation with no thread visible

The installation requires a twin-pin driver. Twodriver bits of the appropriate size are suppliedwith each Ancon system. This type of fixing,known as ‘Snake Eyes’*, allows a high torqueto be achieved without damage to the pin.

The female section of the pin is locatedthrough the fork connector and temporarilyheld in position. A second driver is then usedto wind the male section into position creatinga secure connection.

Each stainless steel fork connector is suppliedwith two clear, self-adhesive, PET (polyester)washers to isolate the system from aconnecting plate of a dissimilar metal. Thesewashers should be applied around the fixinghole, either side of the plate, prior to theinstallation of the fork connector.

Locking nuts screwed back to forks andtightened using hook spanners.

Bar screwed into the forks using openended spanners.

Locking nuts screwed completely onto thetension bar.

Left hand thread

Right hand thread

-

-

+

+

*‘Snake Eyes’ is the registered trademark of Tamperproof Screw Company Inc.

Page 15: Ancon 500 Tension Systems

OTHER ANCON PRODUCTS

Wall Ties and Restraint FixingsAncon’s standard range includes cavity wallties for all types of construction includingtraditional brick/block, thin-joint blockwork andtimber or steel frames. Many fixings can besupplied within twenty-four hours of receivingan order. Bespoke wall ties can be ordered byusing a simple reference system for the head,shank and tail of the tie.

Masonry Support SystemsMasonry cladding on steel or concrete framedstructures is normally supported from astainless steel support system, positionedabove the horizontal movement joints. Ancondesigns solutions for all conditions including thesupport of special masonry features. The rangeincludes the standard AnconOptima systemconsisting of short lengths of angle andinterchangeable brackets of various depths toaccommodate variations in cavity width on site.

Windposts and Parapet PostsLarge panels of masonry or panels withopenings can often be difficult to justifystructurally. Ancon Windposts are designed toprovide additional lateral support for panels ofbrickwork. The range is manufactured fromstainless steel and includes Windposts whichcan be installed into the inner leaf of blockworkand Windposts for installation into the cavity,which leave the blockwork undisturbed.Parapet Posts are used as vertical support forbrickwork in either parapet or spandrel panels.Ancon Windposts and Parapet Posts aredesigned specifically for each application.

Insulated Balcony ConnectorsAncon Isolan connectors join external concretebalconies to internal floor slabs. Used tominimise cold bridging, they provide continuityto the thermal insulation. Standard systems,comprising rigid CFC-free polystyrene insulationand duplex stainless steel shear reinforcement,suit most depths of cantilevered and simplysupported balconies. Conventional reinforcingbars are used to provide the tension andcompression reinforcement.

Shear Load ConnectorsAncon DSD and ESD Shear Load Connectorsare used to transfer shear across expansionand contraction joints in concrete. They aremore effective at transferring load and allowingmovement to take place than standard dowels,and can be used to eliminate double columnsat structural movement joints in buildings.

For further information or advice on specificapplications please contact Ancon’s TechnicalServices Team.

Maximummisalignment

0.5˚

Fork ends of the tension system mustbe positioned in the same plane

Forks must be correctly aligned, and positionedin the same plane to ensure that bending is notintroduced into the tension system.

The maximum misalignment of an AnconSystem is 0.5˚ as illustrated below.

15

Tel: +44 (0) 114 275 5224 Web: www.ancon.co.uk

Page 16: Ancon 500 Tension Systems

© Ancon Building Products 2008

The construction applications and details provided in this literatureare indicative only. In every case, project working details should beentrusted to appropriately qualified and experienced persons.

Whilst every care has been exercised in the preparation of thisdocument to ensure that any advice, recommendations orinformation is accurate, no liability or responsibility of any kind isaccepted in respect of Ancon Building Products.

With a policy of continuous product development Ancon BuildingProducts reserves the right to modify product design andspecification without due notice.

These products are available from:

Ancon Building ProductsPresident Way, President ParkSheffield S4 7URUnited KingdomTel: +44 (0) 114 275 5224Fax: +44 (0) 114 276 8543Email: [email protected]: www.ancon.co.uk

Ancon (Middle East) FZEPO Box 17225Jebel AliDubaiUnited Arab EmiratesTel: +971 (0) 4 883 4346Fax: +971 (0) 4 883 4347Email: [email protected]: www.ancon.ae

Ancon Building Products114 Kurrajong AvenueMount DruittSydneyNSW 2770AustraliaTel: +61 (0) 2 8808 1111Fax: +61 (0) 2 9675 3390Email: [email protected]: www.anconbp.com.au

Ancon (Schweiz) AGGewerbezone Widalmi 103216 Ried bei KerzersSwitzerlandTel: +41 (0) 31 750 3030Fax: +41 (0) 31 750 3033 Email: [email protected]: www.ancon.ch

Ancon Building Products GesmbHGerspergasse 9/3 Top 1A-1210 ViennaAustriaTel: +43 (0) 1 259 58 62-0Fax: +43 (0) 1 259 58 62-40Email: [email protected]: www.ancon.at

Ancon GmbHBartholomäusstrasse 2690489 NurembergGermanyTel: +49 (0) 911 955 1234 0Fax: +49 (0) 911 955 1234 9Email: [email protected]: www.anconbp.de

ISO 9001: 2000FM 12226

ISO 14001: 2004EMS 505377