an ideal wastewater treatment plant constructed …...• possibility of remote supervision over the...

4
AS-IDEAL PZV 2-10 E0 An ideal wastewater treatment plant constructed under the notification duty and discharging to subsurface infiltration systems The AS-IDEAL PZV wastewater treatment plant is particularly suitable in places, where it is not possible to discharge cleaned wastewater to sewers, water streams, agricultural drains, etc. It is designed for family houses, hotels, boarding houses and other various facilities. The advantages of the AS-IDEAL PZV (WWTP) and its AS-Klärmax IDEAL built-in section are as follows • “Ideal” wastewater treatment plant upon the notification duty • Robust tank • Simple technology with well-proven, high reliability and efficiency • Sludge problems solved • Sampling without difficulties • Possibility of sanitization at the plant outlet • Potential use of cleaned water for irrigation purposes • Possibility of remote supervision over the wastewater treatment operations • The prices includes the inlet conduit and the cover • Advantageous price for a notification-duty PZV-type plant WWTP AS-IDEAL PZV with AS-Klärmax IDEAL built-in section This type range of household treatment plants has been created by a combination of the AS-MONA plastic cast tanks providing the necessary stability and the German AS-Klärmax IDEAL built-in sections providing top efficiency as the reaction to stricter outlet parameters stipu-lated recently by the Government Regulations No. 57/2016 Coll., and No. 401/2015 Coll.

Upload: others

Post on 05-Apr-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: An ideal wastewater treatment plant constructed …...• Possibility of remote supervision over the wastewater treatment operations • The prices includes the inlet conduit and the

AS-IDEAL PZV 2-10 E0

An ideal wastewater treatment plant constructed under the notification

duty and discharging to subsurface infiltration systems

The AS-IDEAL PZV wastewater treatment plant is particularly suitable in places, where it is not possible to discharge cleaned wastewater to sewers, water streams, agricultural drains, etc. It is designed for family houses, hotels, boarding houses and other various facilities.

The advantages of the AS-IDEAL PZV (WWTP) and its AS-Klärmax IDEAL built-in section are as follows

•“Ideal”wastewatertreatmentplantuponthenotificationduty•Robusttank•Simpletechnologywithwell-proven,highreliabilityandefficiency•Sludgeproblemssolved•Samplingwithoutdifficulties•Possibilityofsanitizationattheplantoutlet•Potentialuseofcleanedwaterforirrigationpurposes•Possibilityofremotesupervisionoverthewastewater treatmentoperations•Thepricesincludestheinletconduitandthecover•Advantageouspriceforanotification-dutyPZV-typeplant

WWTPAS-IDEALPZVwithAS-KlärmaxIDEALbuilt-insection

ThistyperangeofhouseholdtreatmentplantshasbeencreatedbyacombinationoftheAS-MONAplasticcasttanksprovidingthenecessarystabilityandtheGermanAS-KlärmaxIDEALbuilt-insectionsprovidingtopefficiencyasthereactiontostricteroutletparametersstipu-latedrecentlybytheGovernmentRegulationsNo.57/2016Coll.,andNo.401/2015Coll.

Page 2: An ideal wastewater treatment plant constructed …...• Possibility of remote supervision over the wastewater treatment operations • The prices includes the inlet conduit and the

Note:Thestandardheightoftheconduitis500mmandthesupplyincludesaplastictrafficablecover(load-bearingcapacity:200kg).

Table for designers

AS-IDEAL PZV size

PE number

Nominal daily flowrate [m3/day]

Nominal loading with substances

[kgBOD5/day]

Diameter x height of the conduit

[mm]

Inlet outlet heights Hv[mm]/Ho[mm]

Weight[kg]

mini 2–3 0.45 0.18 Ø1350x1800 1530/1480 120

5 4–5 0.75 0.30 Ø1350x2300 1930/1880 140

7 6–7 1.05 0.42 Ø1750x1800 1470/1420 155

10 8–10 1.50 0.60 Ø1750x2300 2090/2040 185

Treatment technology description

AS-IDEALPZVisanactivation&aerobicwastewatertreatmentplant.Thecontaminantscontainedinwastewaterareremovedbymechanical-biologicalprocessesintheso-calledSBRreactor.Intheaerationprocess,asimpletankandatime-controlledpurificationcyclerunningduringthedayareused.Ontheotherhand,thesedimentationphaseisintendedfornighthours,whichreflectstheusualhouseholdconditions.

•PhaseI–thisistheaerationphase,duringwhichthetankisbeingfilledandaerobicpurificationprocessestakeplace;floatingmicroorganismsaggregatedtoflocculiremoveorganicimpuritiesresultingintheaerobicdegradationprocessandconvertthemtobiomass.

•PhaseII–thesedimentationprocessfollowsveryquicklyduringnighthoursandflocculisedimentationcreatesaninterfacebetweentheactivatedsludgeandcleanedwater.

•PhaseIII–Afterthesedimentationprocess,whichusuallylastssome1.5hours,cleanedwaterisdrawnofftothedischargetroughortothetankforsamplingbytheuseofanairliftpump.

Test results – a comparison with PZV

Requirement COD BOD5 Insolublesubstances NH4-N Ntotal* Ptotal

PIA result 96,30% 99,00% 98,80% 96,40% 87,50% 66,00%

NV 57/2016 Coll. 90,00% 95,00% notrequired notrequired 50,00% 40,00%

*Inthecaseofaplantdesignforfacilitieswithaccommodationservices,theNtotalparametershouldbeconsideredindividually.

Valuesthatareusuallyachievedincontinuouslyoccupiedpremisesincasesoftypicalwater-rightproceedingsareasfollows:COD=130mg/l,BOD5=30mg/l,insolublematerials=30mg/l,NH4-N=20mg/l,Ntotal=30mg/l,Ptotal=8mg/l

Sludge

Theequipmentadvantageisahighlevelofsludgemineralisation,whichresultsinlowsludgeproduction.Allthesludgequantityisaerobicallystabilised.

Dependingonthetypeofwastewatertreatmentplants,thereareseveraldisposalpossibilitiesofsurplussludge:

•SS type:anothertankorexternaldewateringequipment,

•SSC type:integrateddewateringequipment(optionallysuppliedwiththeplant);thedewateredsludgecanbethencomposted.ThecompostersarealsoofferedbyAsio,spol.sr.o.,

•Easy type:thesludgeisdirectlydrawnofffromtheprocessandtransportedtoalargerwastewatertreatmentplant(usuallyamunicipalplant).

Page 3: An ideal wastewater treatment plant constructed …...• Possibility of remote supervision over the wastewater treatment operations • The prices includes the inlet conduit and the

DN150INLET DN150

OUTLET

DN150INLET

DN150OUTLET

Ø 75 MM PROTECTIVESLEEVE FOR AIR HOSES

1

23

45

6

7

Hv

Ho

H1

ØD

H2

45°

Hw

wtp

Explanations:1 - Inlet2 - Outlet 3 - Outlet airlift pump4 - Inlet conduit5 - Sludge draining basket6 - Aeration element7 - Concrete slab

Blower

Control unit

230 V AC230 V AC

Sludge tank

Blower

Control unit

Type SSC

Type easy

Type SS

Page 4: An ideal wastewater treatment plant constructed …...• Possibility of remote supervision over the wastewater treatment operations • The prices includes the inlet conduit and the

prin

ted

07/2

016

www.asio.cz

Equipment installation

Theequipmentinstallationiseasy–thetankisplacedintoanexcavationpit,thenitisconnectedtoasewerand,bythehosesrunningintheprotectivesleeve,tothecontrolcabinet(blower,valvesanddistributingpanel).Consequently,thecabinetisconnectedtopowersupply(240V).

Sampling

Iftherelevantwastewatertreatmentplantistobeoperatedwithintheconventionalwater-rightproceedings,itisadvisabletoinstallanaccumulationtank(forsampling)intotheequipment.Insuchcase,itwillbepossibletotakethesimplesamplesinaone-offoperation,whichismoreadvantageous.

Other possibilities

•Thewastewatertreatmentplantcanbeadditionallyfittedwithapumpandthewholeprocessadjustforthepurposeofusingthestoragespaceintheplantdirectlyforirrigation,withoutanyfurthertankbeingnecessary.

•ThewastewatertreatmentplantcanbemonitoredbytheAS-GSMapplication.Thismakespossibletomonitortheoperationsandinformtheowneraboutfailures(ifany)bySMSmessages.

•SanitationsafetycanbeprovidedbyanUVlamp;ifrequiredbythehydrogeologist,wastewatertreatmentplantwillbesuppliedwiththeUVlamp.

Kšírova552/45,61900Brno,CzechRepublicPhone:+420548428111E-mail:[email protected],www.asio.cz

ASIO Ltd.

Use of the individual AS-Klärmax IDEAL built-in section in an existing tank or digestion (septic) tank

Incaseofasuitablegeometricalsimilarity,itwillbepossibletousetheAS-KlärmaxIDEALbuilt-insectionevenindependentlyduringrefurbishmentorintensificationprojectsinexistingfacilities,withtheaimofachievingthevaluesstipulatedbytheGovernmentalRegulations.Inplaces,wheretheplanttankistravelledoverbyvariousvehicles,thenthebuilt-insectioncanbeplacedinsideconcretetanks.

AS-KlärmaxIDEALbuilt-insection