an energized roof our advantages - residential and … · 2020-04-23 · our advantages ul listed /...
TRANSCRIPT
MERLIN® manufactures sustainable solar energy solutions for commercial, industrial and residential roofing, as well as transportation, portable and wearable applications. We believe that our unique solar energy solutions will make the world rethink what solar energy is capable of.
WHO WE ARE
UPGRADE YOUR METAL ROOF WITH FLEXIBLE SOLAR PANELS
The amount of money and resources spent on electricity is increasing every year. Even as buildings become more energy efficient, technology devices increase the demand for power. Electricity rates are rising and the need for dependable renewable energy is higher than ever before.Our roofing solar panels can reduce, or even eliminate, your electricity bill with its enhanced energy output and efficiency. The simple peel-and-stick application makes the installation process inexpensive and quick. Our extremely light construction can eliminate the need to make structural enhancements to existing roofs. These flexible sheets can easily adapt to the shape of your roof and give it a superior look while maintaining its durability.
IS YOUR ELECTRICITY BILL SOARING HIGH?
AN ENERGIZED ROOFOUR ADVANTAGES
UL listed / IEC Approved / CEC listed
High performance levels
Rugged, strong & durable
Stable reinforcement to the solar cell
Reliability of c-Si solar cells
Enhanced production in low / diffused light
“Redundancy” by design
Fast & easy peel-and-stick installation
Low installation cost
Penetration-free design
Maximized tax credit benefit
Enhanced energy output
Superior aesthetics
High durability & reliability
BENEFITS OF SOLARINTEGRATED ROOFING
TECHNICAL DATA
Electrical Characteristics (STC)1 MERLIN® PV Module
Cell Type
Number in series
Rated Power (Pmax) W
V
A
V
A
A
VDC
°C
°C
%
%/°C
%/°C
%/°C
Voltage at Pmax (Vmp)
Current at Pmax (Imp)
Open-circuit Voltage (Voc)
Short-circuit Current (Isc)
Active Area Efficiency
Temperature Co-efficient of Isc
Temperature Co-efficient of Voc
Temperature Co-efficient of Pmax
Maximum series fuse rating
Maximum system voltage
Nominal Operating Cell Temperature (NOCT)3
Operating temperature
Termination
Unit
165
19.34
8.54
23.25
8.81
18.76
36
160
18.92
8.46
23.01
8.72
18.19
0.05
-0.33
-0.42
15
600
45 +/- 2
- 40 to + 85
155
18.58
8.35
22.67
8.61
17.62
Model: FX36L & FX36S
155
Mono
160 165
24
105
12.53
8.39
15.21
8.65
17.91
0.05
-0.33
-0.42
15
600
45 +/- 2
110
12.89
8.54
15.5
8.81
18.76
100
12.15
8.24
14.98
8.49
17.06
- 40 to + 85
Model: FX24LProperty
Mono
100 105 110
Jbox with PV cable and polarize connectors
1. STC standard test conditions: 1000W/m2 intensity, Air Mass 1.5, 25OC cell temperature. The power tolerance is -3% / +3% W, at STC. The electrical characteristics are within ±10%.2. The power tolerance is -3% / +3% W, at STC. The electrical characteristics are within ±10% unless otherwise specified. 3. Mounting on SS metal roof.
Model FX36S
Units mm / kg in / lb
Length 1068 42.05
Width 987 38.86
Thickness* 3 0.12
Weight 4.41 9.75
Model FX36L
Units mm / kg in / lb
Length 2938 117.44
Width 372 14.65
Thickness* 3 0.12
Weight 4.7 10.4
Model FX24L
Units mm / kg in / lb
Length 2030 79.92
Width 372 14.65
Thickness* 3 0.12
Weight 3.7 6.9
IV Curves PV Module FX24L-10510
8
6
Cur
rent
[A]
4
2
00 2 4 6 8Voltage [V]
10 12 14 16
Incident Irrad. = 1000 W/m2
Incident Irrad. = 800 W/m2
Incident Irrad. = 600 W/m2
Incident Irrad. = 400 W/m2
Incident Irrad. = 200 W/m2
104.7 W
83.8 W
62.7 W
41.5 W
20.3 W
IV Curves PV Module FX 36L & 36R-16010
8
6
Cur
rent
[A]
4
2
00 2 4 6 8Voltage [V]
10 12 14 16
Incident Irrad. = 1000 W/m2
Incident Irrad. = 800 W/m2
Incident Irrad. = 600 W/m2
Incident Irrad. = 400 W/m2
Incident Irrad. = 200 W/m2
160.7 W
128.4 W
95.9 W
63.3 W
30.9 W
For further details, contact: MERLIN SOLAR TECHNOLOGIES, INC.
5891 Rue Ferrari, San Jose, CA 95138 | Ph: (408) 321-8258
E-mail: [email protected] | www.merlinsolar.com© 2019 Merlin Solar Technologies, Inc.
Distributed by:
UL Standard 1703
IEC 61215/61730
Warranted upto 20 years
Materials and workmanship 5 years
Power output 20 years
QUALIFICATIONS
90% of nominal rated power for years 1-10
80% of nominal rated power for years 11-20
Length
Wid
th
Length
Width
Wid
th
Length
*Panel at the junction box area 21mm high.