RESIDENTIAL HORIZONTAL CLADDING
www.metalcraftgroup.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: Frances.charles@unitedindustries.co.nz
MetalcraftRoofing
Bevelback Weatherboard
RHBW
DETAIL LIST
00 / 23 COVER SHEET01 / 23 PARAPET AND BALUSTRADE CAPPING02 / 23 SOFFIT03 / 23 FLUSH WINDOW HEAD04 / 23 FLUSH WINDOW SILL05 / 23 FLUSH WINDOW JAMB06 / 23 RECESSED WINDOW HEAD07 / 23 RECESSED WINDOW SILL08 / 23 RECESSED WINDOW JAMB09 / 23 BUTT WINDOW HEAD10 / 23 BUTT WINDOW SILL11 / 23 BUTT WINDOW JAMB12 / 23 METERBOX HEAD13 / 23 METERBOX SILL14 / 23 METERBOX JAMB15 / 23 INTERNAL CORNER16 / 23 EXTERNAL CORNER17 / 23 INTERNAL CORNER BOX TYPE18 / 23 EXTERNAL CORNER BOX TYPE19 / 23 SOAKER FLASHING20 / 23 VERTICAL BUTT JOINT21 / 23 BOTTOM OF CLADDING (FLUSH)22 / 23 BOTTOM OF CLADDING (RECESSED)23 / 23 3D WINDOW FLASHINGS
DETAIL LIST
PRE-FINISHED PARAPET CAP FLASHINGNO FIXINGS ON TOP OF FLASHING
PERMEABLE WALL UNDERLAY, SHOWNDASHED
CONTINUOUS H3.1 TIMBER PACKINGTO GIVE 5° FALL INWARDS
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
WALL FRAMING
MIN
. 5.00 °PERMEABLE WALL UNDERLAY TO PROVIDESEPARATION OF METAL CAPPING ANDCLADDING WITH TIMBER, SHOWN DASHED
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
20mm CAVITY
Z
CLE
ARAN
CE
3mm
MIN
CLE
ARAN
CE
25m
m
Z
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCLADDING AND BATTEN AS NECESSARY
PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORSHANK NAIL
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)
MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)
MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Z
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
SITUATION 1
1. LOW, MEDIUM, HIGH WINDZONES, WHERE ROOF PITCH ≥ 10°
MIN. 50mm
SITUATION 2
1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°
MIN. 70mmZ
SITUATION 3
1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES
MIN. 90mm
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
PARAPET AND BALUSTRADE CAPPING
01 / 232018
PERMEABLE WALL UNDRLAY, SHOWNDASHED
20mm CAVITY
WALL FRAMING
METALCRAFT BEVELBACKWEATHERBOARD PROFILE
PRE-FINISHED SOFFIT FLASHING
FLY RAFTER
BARGE BOARD
SOFFIT LINING
PURLIN
INTERNAL CEILING LINING
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
EXTRA NOG FOR TOP FIXING OFWALL CLADDING
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCLADDING AND BATTEN AS NECESSARY
INTERNAL WALL LINING
SQUARE STOP CORNICE
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL
Z
50mm MINSTSR OR GALV. FLATHEAD NAIL FOR FLASHING
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)
MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)
MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Z
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
SITUATION 1
1. LOW, MEDIUM, HIGH WINDZONES, WHERE ROOF PITCH ≥ 10°
MIN. 50mm
SITUATION 2
1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°
MIN. 70mmZ
SITUATION 3
1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES
MIN. 90mm
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
SOFFIT
02 / 232018
PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED
INTERNAL WALL LINING
WINDOW LINTEL FRAMING
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
DOUBLE GLAZING WINDOWJOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMB LINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
STST OR GALV. FLAT HEAD NAIL FORFLASHING
PVC CAVITY CLOSER
COMPRESSIBLE FOAM SEAL TOFILL OVERLAP OF FLASHING
MIN
. 10m
m C
OVE
R
SUG
GES
T M
IN. 5
0mm
DIM
ENSI
ON
TO
SU
IT
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50m
m C
OVE
R
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL
5 m
m G
AP
DR
IP E
DG
E TO
CLA
DD
ING
MIN
. 15
mm
GAP
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
FLUSH WINDOW HEAD
03 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
INTERNAL WALL LINING
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW JAMB LINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL
PRE-FINISHED WINDOW SILL FLASHING
WALL FRAMING
PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT SILL
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
20mm CAVITY
WINDOW SUPPORT BAR
PRE-FINISHED SECONDARY FLASHING
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHING ANDCLADDING WITH TIMBER, SHOWNDASHED
PRE-FINISHED TEK SCREW WITH RUBBERWASHER OR SHANK NAIL
MIN
. 8m
m C
OVE
R
5mm GAP
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
50m
m C
OVE
R
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
FLUSH WINDOW SILL
04 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
INTERNAL WALL LINING
LINE OF SILL FLASHING BELOW
PRE-FINISHED TEK SCREW WITH RUBBERWASHER OR SHANK NAIL
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL
20mm CAVITY
LINE OF SILL FLASHING BELOW
PRE-FINISHED WINDOW JAMBFLASHING
COMPRESSIBLE FOAM SEAL TO FILLOVERLAP OF FLASHING AT HEAD FLASHING
MIN. 10mm COVER
5mm
GAP
PRE-FINISHED SECONDARY FLASHING
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
STST OR GALV. FLAT HEAD NAIL FORFLASHING
SUGGEST MIN. 50mm
DIMENSION TO SUIT
LINE OF HEAD FLASHING ABOVE
CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHINGAND CLADDING WITH TIMBER, SHOWNDASHED
LINE OF HEAD FLASHING ABOVE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
FLUSH WINDOW JAMB
05 / 232018
PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA PERMEABLE WALL UNDERLAY OVERWINDOW HEAD FLASHING, SHOWN DASHED
INTERNAL WALL LINING
WINDOW LINTEL FRAMING
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMB LINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
PVC CAVITY CLOSER
STST OR GALV. FLAT HEAD NAIL FORFLASHING
SUG
GES
T M
IN. 5
0mm
DIM
ENSI
ON
TO
SU
IT
20mm CAVITY
MIN
. 10m
m C
OVE
R
PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORSHANK NAIL
5 m
m G
AP
DR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m G
AP
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50m
m C
OVE
R
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
RECESSED WINDOW HEAD
06 / 232018
5mm GAP
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
INTERNAL WALL LINING
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW JAMB LINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
PRE-FINISHED WINDOW SILL FLASHING
WALL FRAMING
PERMEABLE WALL UNDERLAY, SHOWNDASHED
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
20mm CAVITY
WINDOW SUPPORT BAR
PRE-FINISHED SECONDARY FLASHING
SEPERATE BATTEN AND CLADDINGWITH DPC AS REQUIRED
FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL
5mm
GAP
MIN
. 8m
m C
OVE
R
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
CO
VER
CLA
DD
ING
50m
m(3
5mm
MIN
)
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
RECESSED WINDOW SILL
07 / 232018
PRE-FINISHED WINDOW JAMBFLASHING
PERMEABLE WALL UNDERLAY, SHOWNDASHED
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
INTERNAL WALL LINING
LINE OF SILL FLASHING BELOW
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION3.0 /2017 FOR REQUIREMENT.
METALCRAFT BEVELBACKWEATHERBOARD PROFILE
PRE-FINISHED SECONDARYFLASHING
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED
STST OR GALV. FLAT HEAD NAILFOR FLASHING
LINE OF HEAD FLASHING ABOVE
LINE OF HEAD FLASHING ABOVE
MIN. 10mm COVER
5mm GAP
SUGGEST MIN. 50mm
DIMENSION TO SUIT
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
RECESSED WINDOW JAMB
08 / 232018
PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA PERMEABLE WALL UNDERLAY OVERWINDOW HEAD FLASHING, SHOWN DASHED
INTERNAL WALL LINING
WINDOW LINTEL FRAMING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMB LINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
PVC CAVITY CLOSER
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
DR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m G
AP
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50M
M C
OVE
RSU
GG
EST
MIN
. 50m
m
DIM
ENSI
ON
TO
SU
IT
MIN
. 10m
m C
OVE
R
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
5 m
m G
APReference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
BUTT WINDOW HEAD
09 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
INTERNAL WALL LINING
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW JAMB LINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL
PRE-FINISHED WINDOW SILL FLASHING
WALL FRAMING
PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT SILL
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
20mm CAVITY
WINDOW SUPPORT BAR
PRE-FINISHED SECONDARY FLASHING
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREWPERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHINGAND CLADDING WITH TIMBER,SHOWN DASHED
5mm
GAP
MIN
. 8m
m C
OVE
R
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
5mm GAP
CO
VER
CLA
DD
ING
50m
m(M
IN. 3
5mm
)
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
BUTT WINDOW SILL
10 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
INTERNAL WALL LINING
LINE OF SILL FLASHING BELOW
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL
CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.
PRE-FINISHED WINDOW JAMBFLASHING
5mm GAP5mm GAP
MIN. 50mm MIN. 10mm COVER
5mm
GAP
STST OR GALV. FLAT HEAD NAILFOR FLASHING
PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING AND CLADDINGWITH TIMBER, SHOWN DASHED
SUGGEST MIN.50mm
DIMENSION TO SUIT
LINE OF HEAD FLASHING ABOVE
LINE OF HEAD FLASHING ABOVEPRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
BUTT WINDOW JAMB
11 / 232018
PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED, REMOVEDAFTER FIXING
PRE-FINISHED HEAD FLASHING WITH 15° FALL
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
METER BOX
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
PRE-FINISHED 'U' BRACKET FIXED TOMETERBOX BEFORE INSTALLATION
EXTRA PERMEABLE WALL UNDERLAY OVERWINDOW HEAD FLASHING, SHOWN DASHED
INTERNAL WALL LINING
PVC CAVITY CLOSER
STST OR GALV. FLAT HEAD NAIL FOR FLASHING
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PRE-FINISHED SELF-TAPPING TEK SCREWWITH RUBBER WASHER
MIN
.75m
m W
ITH
OU
T H
E M E
DG
E
MIN
.50m
m C
OVE
R
DR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m G
AP
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
5 m
m G
APReference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
METERBOX HEAD
12 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
METER BOX
INTERNAL WALL LINING
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
WALL FRAMING
20mm CAVITY
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
PRE-FINISHED FLASHING
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
STOPENDS TO SILL FLASHING
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
CO
VER
CLA
DD
ING
50m
m(M
IN.3
5mm
)
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
METERBOX SILL
13 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
METER BOX
TIMBER PACKER
INTERNAL WALL LINING
LINE OF SILL FLASHING BELOW
FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED WINDOW JAMB FLASHING FIXEDTO METERBOX BEFORE INSTALLATION
PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW
METAL ANGLE TO BE CONTINUOUS AROUNDMETER BOX WITH PRE-FINISHED SELFDRILLING/TAPPING SCREW WITH RUBBERWASHER
CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED
STST OR GALV. FLAT HEAD NAILFOR FLASHING
PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW
SUGGEST MIN. 50mm
DIMENSION TO SUIT
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
WINDOW JAMB FLASHINGFIXED TO METAL ANGLE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
METERBOX JAMB
14 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
WALL FRAMING
20mm CAVITY
PRE-FINISHED INTERNALCORNER FLASHING
INTERNAL WALL LINING
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
PERMEABLE WALL UNDERLAY, SHOWNDASHED
SUG
GES
T M
IN. 7
5mm
DIM
ENSI
ON
TO
SU
IT
SUGGEST MIN. 75mm
DIMENSION TO SUIT
CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.
STST OR GALV. FLAT HEAD NAIL FORFLASHING
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHING ANDCLADDING WITH TIMBERM, SHOWNDASHED
PRE-FINISHED SECONDARY FLASHING
PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
INTERNAL CORNER
15 / 232018
20mm CAVITY
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
INTERNAL WALL LINING
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
WALL FRAMING
PRE-FINISHED EXTERNALCORNER FLASHING
PERMEABLE WALL UNDERLAY, SHOWNDASHED
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION 3.0/2017 FOR REQUIRMENT.
PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING ANDCLADDING WITH TIMBER,SHOWN DASHED
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW
STST OR GALV. FLAT HEAD NAIL FORFLASHING
PRE-FINISHED SECONDARYFLASHING
SUGGEST MIN. 75mm
DIMENSION TO SUIT
SUG
GES
T M
IN. 7
5mm
DIM
ENSI
ON
TO
SU
IT
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
EXTERNAL CORNER
16 / 232018
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
WALL FRAMING
20mm CAVITY
PRE-FINISHED INTERNAL CORNERFLASHING
INTERNAL WALL LINING
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
PERMEABLE WALL UNDERLAY,SHOWN DASHED
MIN. 50mm COVER
MN
. 50m
m C
OVE
RCONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017 FORREQUIRMENT.
STST OR GALV. FLAT HEAD NAIL FORFLASHING
5mm
GAP
5mm GAP
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF FLASHINGAND CLADDING WITH TIMBER, SHOWNDASHED
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
INTERNAL CORNER BOX TYPE
17 / 232018
20mm CAVITY
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
INTERNAL WALL LINING
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
WALL FRAMING
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED
MIN. 50mm COVER
MIN
. 50m
m C
OVE
R5mm
GAP
5mm GAP
PERMEABLE WALL UNDERLAY, SHOWNDASHED
PRE-FINISHED EXTERNAL CORNERFLASHING
CONTINUOUSCOMPRESSIBLE FOAM SEAL.REFER TO MRM CODE OFPRACTICE VERSION 3.0 /2017FOR REQUIRMENT.
STST OR GALV. FLAT HEAD NAIL FORFLASHING
MIN
. 70m
m
MIN. 70mm
PRE-FINISHED TEK SCREW WITH RUBBERWASHER OR SHANK NAIL
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
EXTERNAL CORNER BOX TYPE
18 / 232018
PERMEABLE WALL UNDERLAY,SHOWN DASHED
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PRE-FINISHED FLAT HEADWAFER-TEK SCREW FORFLASHING
INTERNAL WALL LINING
20mm CAVITY
WALL FRAMING
PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORLUG NAIL
PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING ANDCLADDING WITH TIMBER,SHOWN DASHED
SOAKER FLASHING ONLY REQUIREDTO LINE UP WITH WINDOW JAMBABOVE.REFER TO MRM CODE OF PRACTICEVERSION 3.0 /2017 FOR REQUIRMENT.
80
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
SOAKER FLASHING
19 / 232018
PERMEABLE WALLUNDERLAY, SHOWN DASHED
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PRE-FINISHED TEK SCREWWITH RUBBER WASHER ORSHANK NAIL
INTERNAL WALL LINING
WALL FRAMING
PRE-FINISHED JOINTERFLASHING
PERMEABLE WALL UNDERLAYTO PROVIDE SEPARATION OFMETAL CAPPING ANDCLADDING WITH TIMBER,SHOWN DASHED
5mm GAP
MIN. 50mm COVER
CONTINUOUSCOMPRESSIBLE FOAMSEAL. REFER TO MRM CODEOF PRACTICE VERSION 3.0/2017 FOR REQUIRMENT.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
VERTICAL BUTT JOINT
20 / 232018
20mm CAVITY
INTERNAL WALL LINING
WALL FRAMING
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PRE-PRIMED SKIRTING
CONCRETE SLAB
PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL
STST OR GALV. FLAT HEAD NAIL FORFLASHING
PERMEABLE WALL UNDERLAY OVERFLASHING, SHOWN DASHED
PVC CAVITY CLOSER
MIN
. 15m
m D
RIP
ED
GE
MIN
. 50m
m L
AP
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANKNAIL
BOTTOM PLATE ON DPC
VEN
TILA
TIO
N G
AP
5 m
m
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
BOTTOM OF CLADDING (FLUSH)
21 / 232018
INTERNAL WALL LINING
WALL FRAMING
PVC CAVITY CLOSER
PRE-PRIMED SKIRTING
CONCRETE SLAB
MIN
. 50m
m L
AP
20mm CAVITY
METALCRAFT BEVELBACKWEATHERBOARD CLADDING
PERMEABLE WALL UNDERLAY OVERFLASHING, SHOWN DASHED
STST OR GALV. FLAT HEAD NAIL FORFLASHING
PRE-FINISHED TEK SCREW WITHRUBBER WASHER OR SHANK NAIL
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND CLADDING WITHTIMBER, SHOWN DASHED
ALTERNATIVE OPTIONBIRDS BEAK EDGE
5 GAP
20
15
PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL
HEMMED EDGE
VEN
TILA
TIO
N G
AP
5 m
m
BOTTOM PLATE ON DPC MIN
. 75m
m C
OVE
R
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW 1 : 2
BOTTOM OF CLADDING (RECESSED)
22 / 232018
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM code ofpractice version 3.0 / 2017, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.
RESIDENTIAL HORIZONTAL CLADDING
ScaleDate SheetMetalcraftRoofing
Bevelback Weatherboard
RHBW
3D WINDOW FLASHINGS
23 / 232018
HEAD FLASHING
JAMB FLASHING
SILL FLASHING
METALCRAFTBEVELBACKWEATHERBOARDCLADDING
ALUMINIUMWINDOWJOINERY
COMPRESSIBLEFOAM SEALBEHIND TO FILLOVERLAP OFFLASHING
FLUSH WINDOW FLASHINGS RECESSED WINDOW FLASHINGS
HEAD FLASHING
JAMB FLASHING
ALUMINIUMWINDOWJOINERY
SILL FLASHING
METALCRAFTBEVELBACKWEATHERBOARDCLADDING
top related