INTELLIGENT EVACUATION SYSTEMS
2017ENG
DXT 9000 DXT 7000 DXT 3000
WITH SPEAKERS AND INSTALLATION ACCESSORIES
In any place where people live and work, dangererous situations may occur, requiring an effective and efficient evacuation of affected areas, in conditions of maximum safety for all occupants and avoiding panic as much as possible.In these circumstances, time is precious and each second saved means saving human lifes. For this reason the use of Intelligent Evacuation Systems - designed to communicate clear and intelligible instructions - is crucial.
Alarms transmitted using encoded tones, usually generated by sirens or alarm sounders, are a suitable solution where occupants are periodically trained to behave in a specific way depending on the specific alarm.However in crowded places, where occupants are occasional bystanders or even foreigners and need to be reassured and guided along safe routes, it is more effective to use a paging microphone and pre-recorded messages, performed in an intelligible way and containing specific instructions on how to behave in situations of alarm or warning (e.g. how to use escape routes).The normative UNI ISO 7240-19 is in force since 2011, introducing new rules and procedures for the design, installation and maintenance of voice evacuation systems, also known as Sound Systems for Emergency Purposes (SSEP), and the use of EN 54 certified components.The UNI ISO 7240-19 contains all information necessary for designers, installers, maintainance engineers and construction companies. Electronics must include devices and strategies for self-diagnosis and protection, and must be certified by accredited notified bodies according to EN 54-16, plus the loudspeakers must be in accordance with EN 54-24.
Environments which are more critical in terms of occupants’ safety (since they are the most critical to be alerted and evacuated) are those with the highest concentration of people. The risk is high and the area to evacuate particularly extended.Examples: hospitals, schools, shopping centres, sales areas, places of entertainment (cinemas, theatres, clubs, etc.), densely populated buildings (offices buildings), factories (production sites, warehouses, etc.), powerstations, chemical industries, railway stations, subways and airports are the most common structures.
An intelligent EN54-certified evacuation system must be operational 24 hours a day, every day of the year.In case of interruption of the primary power supply, it must be powered by a secondary source and its autonomy must be guaranteed for at least 24 hours in a quiescent condition and for 30 minutes in a working condition.These systems, on which safety depends at all times, must be maintained in perfect working order with periodic inspections. Intelligent evacuation systems must also be connected to the fire detection system, so that they can react in a programmed way without supervisory staff and communicate the status to the fire alarm system.
2
APPLICATIONS
SYSTEMS’ AVAILABILITY
DXT 9000SMALL TO LARGE APPLICATIONS
DXT 9000 is the evolution to the RCF DXT Active Matrix solution range. To design the system, RCF has developed a digital multi-platform where PA-EVAC join PRO-INSTALL systems in a completely scalable and versatile range of configurations and solutions.The system offers a level of reliability that goes beyond standard requirements. The architecture is extremely flexible, based on digital network with Ethernet connection to the outside world through expandable protocol DANTE; it allows centralized or distributed configurations, and each fault is diagnosed and shown in every detail to ensure simplicity, quick check operations and maintenance in order to ensure a fully efficient evacuation.DXT 9000 meets all restrictive requirements imposed by EN 54-16, adding advanced technological solutions, such as access to the system through
the integrity network console; the powerful configuration diagnostics software is both comprehensive, yet easy to use. Moreover, interconnection with third-parties systems is available to facilitate the integration with alarm systems and building automation.DXT 9000 is easy to install thanks to a few connections made with J-type fire-resistant cables and screw terminals connectors, simple to configure, and favorablee in terms of fault-monitoring management and electric consumption, thanks to D+ technology, unique of RCF.
The DXT 9000 configuration software allows to configure, monitor and equalize the system and supervise in real-time EVENTS, FAULTS and FAILURES.
CONFIGURATION SOFTWARE
Equipped with a gooseneckmicrophone, can be directly connected to the MU 9186 or MX 9500 central units.
SELECTIVE CALL PAGINGMICROPHONES
3
Applications
• Shopping centres• Hospitals• Railway stations• Airports• Congress centres• Schools• Stadiums• Skyscrapers
MU 9186RMU 9186
MASTER UNITS
p/n 17170185 p/n 17170160
MU 9186 is the MASTER UNIT without power on-board: it is used when the system
requires a high output power and/or a larger number of zones, and can be obtained
adding one or more power amplifiers model UP 9501 (1 x 500W), UP 9502 (2 x 250W)
or UP 9504 (4 x 125W), connected through the dedicated RCF-Flexicomm data-link port.
MU 9186R is the MASTER UNIT with networking facility on-board; it is used when the
system requires a distributed configuration where several MU 9186R and relevant slave
amplifier units 9501 (1 x 500W), UP 9502 (2 x 250W) or UP 9504 (4 x 125W) connected
through the dedicated RCF-Flexicomm data-link port are part of a large installation with
hundreds of zones.
Main Features
• Digital matrix unit is 8x6 configurable, with routing to any output channel, is also available with integrated power amplifiers.
• Priority evacuation messages resident on main control unit protected and monitored memory. Simultaneous delivery is possible.
• 12 configurable GPI and configurable 8 GPO available on each unit.• Control Center PC application to configure and control all system’s parameters.• Front panel control with LCD display and 8 buttons.• Efficient Digital Signal Processors on inputs and outputs; Parametric EQ, High and Low Pass Filters,
Compressor / Limiter, Level controls provided on inputs and outputs.• The EQ window provides 3-band equalizer for the Background input and the Monitor and Auxiliary
Outputs. 5-band equalizer for the Paging input, Auxiliary inputs and BUS Output.• For all input channels (EVAC microphone, paging stations, microphones and analog inputs) the Gain, EQ
and Dynamic screens will appear in the DSP EDITOR.• Fully parametric high and low frequency filters are available for all the inputs and for the Auxiliary Output.• Compressor available (Threshold, Attack, Release and Ratio) on the Auxiliary inputs and BUS Output.• Dual power supply, allowing both AC and DC operation.• RS 485 serial port for optional program remote control and volume adjustment.• MP3 built-in music source with USB and SD-Card reader.• MU 9186R only: twin LAN ports for DIGITAL AUDIO IN (1 channel from external source) and OUT (2
channels up to 4 sub-systems or 1 channel from 5 to 8 sub-systems)• Digital audio over DANTE protocol
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-002/2014).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
4
MU 9186R
MU 9186
MAIN IN, INTEGRITY NETWORK INPUT AUDIO INPUTS- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 104 dB- INTGRITY NETWORK command volta-ge:
24 V dc
PAGING IN (1, 2) AUDIO INPUTS- Input sensitivity: –60 ÷ –20 dBu- Frequency response (±3 dB): 200 Hz ÷ 16 kHz- Input impedance (1 kHz): 4 kΩ- Signal / noise ratio: 84 dB- Paging console power supply: 24 ÷ 28 V c.c.AUX INPUT- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 94 dBBGM (1, 2, 3) AUDIO INPUTS- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 90 dBMONITOR OUT, AUX OUT, MOH AUDIO OUTPUTS- Max. output level: 1 W su 8 Ω- Output impedance (1 kHz): 60 Ω- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Distortion (THD+N @1W, 1kHz): ≤ 0,01%
GPI (LOGIC INPUTS)- Monitored GPI number: 8- Photo-coupled GPI number: 4GPO (LOGIC OUTPUTS)- Max. applicable voltage: 24 V c.c.- Max. current: 0,3 ARCF FLEXCOM BUS- Channels: 4- Resolution: 24 bit- Sampling frequency: 44,1 kHz24 V DC OUTPUT- Max. output current: 100 mADATA LINK- 1 LAN ETHERNET connector (control)- 2 LAN ETHERNET connector (DANTE Brooklyn II module)- 2 PAGING IN RJ 45 ports- 1 RS485 EUROBLOCK connector- 2 RCF FLEXCOM BUS EUROBLOCK connectors- Operating voltage: 100÷240 V ac (50-60 Hz),
48 V dc
- Max. consumption (power): 60 W
- Operating temperature: –5 ÷ +50 °C (23 ÷ 122 °F)
- Relative humidity: 20 ÷ 90% (non condensing)
MECHANICAL SPECS.- Dimensions (w, h, d): 485 mm, 88 mm, 365 mm
(2 rack units19”)- Net weight: 6,9 kg
TECHNICAL SPECIFICATIONS
5
MX 9504MX 9502
AMPLIFIED MASTER UNITS
MX 9502 and MX 9504 allow the basic system configuration to be built, combining all
necessary inputs and outputs, pre-recorded messaging system, EN 54-16 control and
much more: all that is required for a 500W audio system with two or four constant voltage
speakers lines, suitable for example, to serve a school, a supermarket, a factory building
etc.
Main Features
• Digital matrix unit is 8x6 configurable, with routing to any output channel, is also available with integrated power amplifiers.
• Priority evacuation messages resident on main control unit protected and monitored memory. Simultaneous delivery is possible.
• 12 configurable GPI and configurable 8 GPO available on each unit.• Control Center PC application to configure and control all system’s parameters.• Front panel control with LCD display and 8 buttons.• Efficient Digital Signal Processors on inputs and outputs; Parametric EQ, High and Low Pass Filters,
Compressor / Limiter, Level controls provided on inputs and outputs.• The EQ window provides 3-band equalizer for the Background input and the Monitor and Auxiliary
Outputs. 5-band equalizer for the Paging input, Auxiliary inputs and BUS Output.• For all input channels (EVAC microphone, paging stations, microphones and analog inputs) the Gain, EQ
and Dynamic screens will appear in the DSP EDITOR.• Fully parametric high and low frequency filters are available for all the inputs and for the Auxiliary Output.• Compressor available (Threshold, Attack, Release and Ratio) on the Auxiliary inputs and BUS Output.• Dual power supply, allowing both AC and DC operation.• RS 485 serial port for optional program remote control and volume adjustment.• Power amplifiers based on RCF ClassD+ digital technology, offering industrial reliability grade, the highest
efficiency and the lowest maintenance effort.• Twin LAN ports for DIGITAL AUDIO IN (1 channel from external source) and OUT (2 channels up to 4
sub-systems or 1 channel from 5 to 8 sub-systems)• MP3 built-in music source with USB and SD-Card reader.
Applications
• Shopping centres• Hospitals• Railway stations• Airports• Congress centres• Schools• Stadiums• Skyscrapers
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-002/2014).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
6
p/n 17170175
p/n 17170174
MAIN IN, INTEGRITY NETWORK INPUT AUDIO INPUTS- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 104 dB- INTGRITY NETWORK command voltage:
24 V d.c.
PAGING IN (1, 2) AUDIO INPUTS- Input sensitivity: –60 ÷ –20 dBu- Frequency response (±3 dB): 200 Hz ÷ 16 kHz- Input impedance (1 kHz): 4 kΩ- Signal / noise ratio: 84 dB- Paging console power supply: 24 ÷ 28 V dcAUX INPUT- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 94 dBBGM (1, 2, 3) AUDIO INPUTS- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ
LOUDSPEAKER LINE OUTPUTS- Output voltage: 100 V / 70 V
(selectable by RCF only)- Number of internal amplifiers: 2 (MX 9502), 4 (MX 9504)- Max. power of each amplifier: 250 W (MX 9502)
125 W (MX 9504)- Load minimum impedance for each amplifier:
[100 V] 40 Ω (MX 9502)[70 V] 80 Ω (MX 9504)
20 Ω (MX 9502)40 Ω (MX 9504)
- Loudspeaker line outputs: A1 - A2 - B1 - B2 (MX 9502)A - B - C - D (MX 9504)
- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Distortion (THD+N @1W, 1kHz): ≤ 0.1%MONITOR OUT, AUX OUT, MOH AUDIO OUTPUTS- Max. output level: 1 W on 8 Ω- Output impedance (1 kHz): 60 Ω- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Distortion (THD+N @1W, 1kHz): ≤ 0.01%GPI (LOGIC INPUTS)- Monitored GPI number: 8- Photo-coupled GPI number: 4GPO (LOGIC OUTPUTS)- Max. applicable voltage: 24 V dc- Max. current: 0.3 A
- Dimensions (w, h, d): 485 mm, 88 mm, 365 mm (2 unità rack 19”)
- Net weight: MX 9502 - 8 kg MX 9504 - 8,3 kg
A C V O LTA G E S E L E C TO R A N D F U S E I N S I D E , R E F E R TO I N S T R U C T I O N M A N U A L
W A R N I N G TO REDUCE THE RISKOF FIRE OR ELECTRIC SHOCK, DO NOTEXPOSE THIS EQUIPMENT TO RAIN ORMOISTURE. DO NOT REMOVE COVER.NO USER SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION
SERI
AL N
UMBE
R
GENERAL PURPOSE OUTPUTS
1 2 3 4 5 6 7 8+ - + - + - + - + - + - + - + -
RELAY OUTPUTS (contact load 0,3A - 24V DC)
BGM 3AUX INPUT
GND
PAGING IN 2 PAGING IN 1
FALL BACK INPUT
CMDGND
AUDIO
GENERAL PURPOSE INPUTSMax 100 mA
1 2 3 4 5 6 7 8 9 10 11 12PHOTO-COUPLED INPUTSMONITORED INPUTS
24V DC
ROUTINE MESSAGES ETHERNET
MAD
E IN
ITAL
Y
MOH
MONITOR OUT
AUX OUT
MAIN IN BGM 2 BGM 1
GNDGND 28V GND
BUS IN BUS OUT
FLEXCOM BUS CTRL RS485
1 2 3 4 1 2 3 4
MX1x125W MASTER UNIT
POWER 115/230V ~ 50-60Hz - 60 W max48 V 15 A max
EN54-16COMPLIANCE STICKER
MAX OUTPUT POWER 500 W RMSMINIMUM LOAD IMPEDANCE
70 V (20 ) - 100 V (40 )
+ - + - + - + - + - + - + - + -
Series
SPEAKER LINE OUT
LINE A LINE B- + - + - + - +
LINE C LINE D
SPARE AMP BUS
INPUT- + - +
OUTPUT
A C V O LTA G E S E L E C TO R A N D F U S E I N S I D E , R E F E R TO I N S T R U C T I O N M A N U A L
W A R N I N G TO REDUCE THE RISKOF FIRE OR ELECTRIC SHOCK, DO NOTEXPOSE THIS EQUIPMENT TO RAIN ORMOISTURE. DO NOT REMOVE COVER.NO USER SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION
SERI
AL N
UMBE
R
GENERAL PURPOSE OUTPUTS
1 2 3 4 5 6 7 8+ - + - + - + - + - + - + - + -
RELAY OUTPUTS (contact load 0,3A - 24V DC)
BGM 3AUX INPUT
GND
PAGING IN 2 PAGING IN 1
FALL BACK INPUT
CMDGND
AUDIO
GENERAL PURPOSE INPUTSMax 100 mA
1 2 3 4 5 6 7 8 9 10 11 12PHOTO-COUPLED INPUTSMONITORED INPUTS
24V DC
ROUTINE MESSAGES ETHERNET
MAD
E IN
ITAL
Y
MOH
MONITOR OUT
AUX OUT
MAIN IN BGM 2 BGM 1
GNDGND 28V GND
BUS IN BUS OUT
FLEXCOM BUS CTRL RS485
1 2 3 4 1 2 3 4
MX2x250W MASTER UNIT
POWER 115/230V ~ 50-60Hz - 60 W max48 V 15 A max
EN54-16COMPLIANCE STICKER
MAX OUTPUT POWER 500 W RMSMINIMUM LOAD IMPEDANCE
70 V (20 ) - 100 V (40 )
+ - + - + - + - + - + - + - + -
Series
SPEAKER LINE OUT
LINE A1 LINE A2- + - + - + - +
LINE B1 LINE B2
SPARE AMP BUS
INPUT- + - +
OUTPUT
MX 9502
MX 9504
TECHNICAL SPECIFICATIONS
7
Main Features
• Power amplifiers and power supply technology used in the system are RCF ClassD+ using digital technology and industrial reliability grade in order to offer the highest efficiency and the lowest maintenance effort.
• Single and dual channel amplifiers each have two individually managed and monitored speaker outputs.
• Spare power amplifier connection input present on each unit and the change-over facility for a stand-by power amplifier unit configurable according to priority and group.
• Background music and local paging inputs are available.• 12 configurable GPI and configurable 8 GPO are available on each unit.
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapers
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-002/2014).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
8
UP 9504UP 9502UP 9501POWER AMPLIFIERSIn order to grant a high installation flexibility and output power on a larger number of zones,
DXT 9000 includes three models of RCF ClassD+ power amplifiers, able to deliver up to
500W on 100V or 70V constant voltage speaker lines. In mid-large size systems, models UP
9501 (1 x 500W), UP 9502 (2 x 250W) and UP 9504 (4 x 125W) can be connected to both
MX 9502, MX 9504, MU 9186 and MU 9186R through the dedicated RCF-Flexicomm data-
link port. Moreover, UP 9501 models can be programmed to become a spare power amplifier
for one or more units, and automatically replace them in case of failure.
p/n 17170170
p/n 17170162
p/n 17170161
UP 9504
UP 9502
UP 9501
INTEGRITY NETWORK INPUT AUDIO INPUT- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 104 dB- INTGRITY NETWORK command voltage:
24 V dc
AUX INPUT- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 94 dBBGM 3 AUDIO INPUT- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩLOUDSPEAKER LINE OUTPUTS- Output voltage: 100 V / 70 V
(internal selection)- Number of internal amplifiers: 1 (UP 9501)
2 (UP 9502)4 (UP 9504)
- Max. power of each amplifier: 500 W (UP 9501)250 W (UP 9502)125 W (UP 9504)
- Load minimum impedance for each amplifier:
[100 V] 20 Ω (UP 9501)40 Ω (UP 9502)80 Ω (UP 9504)
[ 70 V] 10 Ω (UP 9501)20 Ω (UP 9502)40 Ω (UP 9504)
- Loudspeaker line outputs: A1-A2 (UP 9501)A1-A2-B1-B2 (UP 9502)
A-B-C-D (UP 9504)- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Distortion (THD+N @1W, 1kHz): ≤ 0.1%GPI (LOGIC INPUTS)- Monitored GPI number: 8- Photo-coupled GPI number: 4GPO (LOGIC OUTPUTS)- Max. applicable voltage: 24 V dc- Max. current: 0.3 ARCF FLEXCOM BUS- Channels: 4- Resolution: 24 bits- Sampling frequency: 44.1 kHz24 V DC OUTPUT- Max. output current: 100 mA- Dimensions (w, h, d): 485 mm, 88 mm,
365mm (2 unità rack 19”)- Net weight: 7,8 kg (UP 9501), 8,0 kg (UP
9502), 8,3 kg (UP 9504)
MAX OUTPUT POWER 500 W RMSMINIMUM LOAD IMPEDANCE
70 V (20 Ω) - 100 V (40 Ω) UP4x125W CLASS D+ POWER AMPLIFIER
A C V O LTA G E S E L E C TO R A N D F U S E I N S I D E , R E F E R TO I N S T R U C T I O N M A N U A L
W A R N I N G TO REDUCE THE RISKOF FIRE OR ELECTRIC SHOCK, DO NOTEXPOSE THIS EQUIPMENT TO RAIN ORMOISTURE. DO NOT REMOVE COVER.NO USER SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION
SERI
AL N
UMBE
R
GENERAL PURPOSE OUTPUTS
1 2 3 4 5 6 7 8RELAY OUTPUTS (contact load 0,3A - 24V DC)
BGM 3AUX INPUT
GND
FALL BACK INPUT
CMDGND
AUDIO
GENERAL PURPOSE INPUTSMax 100 mA
1 2 3 4 5 6 7 8 9 10 11 12PHOTO-COUPLED INPUTSMONITORED INPUTS
24V DC
MAD
E IN
ITAL
Y
POWER 115/230V ~ 50-60Hz - 800 W max48 V 15 A max
EN54-16COMPLIANCE STICKERSeries
SPEAKER LINE OUT
LINE A LINE B- + - + - + - +
LINE C LINE D
SPARE AMP BUS
INPUT- + - +
OUTPUT
GND 28V GND
BUS OUT BUS IN
FLEXCOM BUS CTRL RS485
1 2 3 4 1 2 3 4
TECHNICAL SPECIFICATIONS
9
10
RP 9600DATA REPEATERRP 9600 Data Repeater is the system component that needs to be inserted between the
master unit (either MU 9186 or MU 9186R or MX 9502 or MX 9504) and amplifiers (UP
9501 / UP 9502 / UP 9504) when the bus cable is longer than 180 metres or the system
includes more than 15 UP 950x amplifiers.
Main Features
• RCF FLEXCOM BUS 4 Channels.• Up to 4 units for each system.• Enhance system’s flexibility and layouting• Fully monitored and EN 54-16/2008 certified
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapers
p/n 17170182
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-002/2014).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
11
TECHNICAL SPECIFICATIONS
RCF FLEXCOM BUS
- Resolution: 24 bits- Sampling frequency: 44.1 kHzDATA LINK- LAN ETHERNET connector 1- RCF FLEXCOM BUS EUROBLOCK connectors 2ELECTRICAL SPECS.- Operating voltage: 115 /230 V ac (50-60 Hz), 48 V dc- Max. consumption (power): 60 W- Operating temperature: -5° ÷ +50 °C (23 ÷ 122 °F)- Relative humidity: 20 ÷ 90% (non condensing)MECHANICAL SPECS.- Dimensions (w, h, d): 485 mm, 88 mm, 365 mm (19” rack – 2 units)- Net weight: 6.5 kg
BGM (1, 2, 3) AUDIO INPUTS- Input sensitivity: –50 ÷ +6 dBu- Frequency response (±3 dB): 20 Hz ÷ 20 kHz- Input impedance (1 kHz): 25 kΩ- Signal / noise ratio: 90 dBMONITOR OUT, AUX OUT, MOH AUDIO OUTPUTS- Max. output level: 1 W on 8 Ω- Output impedance (1 kHz): 60 Ω- Frequency response (±3 dB): 20 Hz ÷ 20 kHz
SELECTIVE CALL PAGING MICROPHONESThe BM 9000 series microphone consoles for announcements are part of the DXT 9000 digital system, and can be directly connected to all master units.User can send announcements to different pre-configured zones or groups of zones, recall matrix configurations, intervene on sound levels, select music sources in different areas, send routine messages or alarms stored in the system memory or explore other possibilities. BM 9804 is also available in Firemen version, hosted in a closed wall mounting red metal cabinet, with glass door to access console status.This version is equipped with dynamic microphone, with incorporated push to talk button, and can be used in combination with a BE 9808 (also installed inside the cabinet), to improve selective calls efficiency.
Main Features
• Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface.
• Die-cast metal enclosure with 420 mm gooseneck.• Pre-amplified hyper-cardioid hi-quality microphone with integrated
compressor and limiter to get intelligible announcements even in critical ambients.• Programmable function keys for announcements or commands.• Power supply voltage from the Flexicomm BUS or from 24V DC local input.• Interactive LCD backlit display associated to an encoder that indicates
which operations are active and recovers system information.• Alert and evacuation indications.• Pre-recorded message activation.• 5m connecting cable (with RJ 45 plugs) included.• Dedicated “chime” key.
Applications
• All DXT 9000 applications
12
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-002/2014).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
BM 9804
BE 9808BM 9804 FM
BM 9802p/n 14380024
p/n 14380025
p/n 14380038
p/n 14380023
Type: electret DynamicPolar pattern: cardioid Omni-DirectionalOutput impedance: 470 Ω (1 kHz) 500Ω±30% (1KHz)Microphone sensitivity: – 65 dB ± 3 dB (0 dB=1V/μbar, 1 kHz) -70 dB ± 3 dB (0 dB=V/ μbar, 1 kHz )Frequency response: 50 Hz ÷ 18 kHz (– 3 dB) 300 Hz ÷ 6 kHz (– 3 dB)Dimensions: 128 x 39 x 203 mm (without gooseneck) 360 x 360 x 129 mmGooseneck length: 445.5 mm -Net weight 1.2 kg (2.7 lbs) 6.9 kg (15.2 lbs)
BM 9802 - BM 9804 BM 9804FM
TECHNICAL SPECIFICATIONS
13
BE 9808
BM 9802 BM 9804 BM 9804FM BE 9808
NS 9048 NOISE SENSOR
NS 9048 is a noise detector that automatically adjust the volume level depending on the environment noise. It is specifically addres-sed to all those applications with a significantly different people affluence during the day. It shall be connected to any DXT 9000 power amplifiers and can act on every single system’s zones, measured with a variable number of microphones (up to a maximum of 8).
Main Features
• Up to 8 microphones can be connected on the rear panel.• Specifically designed to work with for 100V speakers used as microphones. However, it can also be used with capsule microphones.• Up 2 units can be connected to the same DXT 9000 amplifier.• Presence led for each microphone.• DATA and LINK leds on the front panel provide feedback on theconnection and data exchange with DXT 9000 amplifiers.• Metal case suitable for ceiling and rack installation.• All connectors on the rear panel, for easier cabling in rack configuration.• Operational voltage: 24V DC or 48V DC from EN54-4 power supplies (PS 4048 or PS 6048).• RS485 maximum distance: 8km, with properly shielded and twisted cable pairs.• Configurable via PC software.
p/n 12399036
Powered by BM 9802 / BM 9804 paging microphone.
Max. current draw: 80 mA (one BE 9808 keyboard only)Dimensions: 78 mm x 39 mm x 203 mmNet weight 0.7 kg (1.6 lbs)
14
IN 9000 EMERGENCY CONSOLE is designed to be interfaced with the evacuation
system DXT9000, in order to provide an analog backup solution for emergency
communications in case of interruption of the main digital connection RCFBUS.
The console is equipped with a monitored FIREMAN microphone with PTT button.
The PTT command is also implemented as dedicated button on the front panel,
together with a Vumeter on the microphone signal and a “on air” indication light. IN
9000 can be powered by an external power supply EN54-4 providing at least 20W
output power. Moreover, a monitored GPI is provided to report any power supply
fault. The audio output can be distributed up to 64 DXT9000 units, and routed on 4
independent lines, selectable on console front panel.
p/n 14322024IN 9000 INTEGRITY NETWORK CONSOLE
Main Features
• Fully analogue redundancy in the event of interruption by the RCF-Flexicomm bus.• Monitored fireman’s microphone with PTT button• Output signal distributed up to 64 DXT 9000 units over 4 selectable independent lines.• Powered by 24V to 48V external supply providing at least 20W output power
MSW 9000SOFTWARE MONITORING DXT 9000
• It allows remote monitoring of the DXT 9000 system by the personnel assigned to its management and control
• Provides real-time information on system status via a web page
• Provides notification functionality via SMS (subscription service) in conjunction with fault, alarm or evacuation events
p/n SW038103
• 20 Hz resonator, with an impedance of 200 Ohm at the resonance frequency
• Installed after the last speaker, it allows to accurately monitor speakers lines integrity.
• Suitable for DXT3000 and DXT9000 systems.
p/n 17170176EOL 3-9END OF LINE
p/n 17170176
MS9000DXT9000 MONITORING SOFTWARE
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapers
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-002/2014).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
DXT 9000 - CONFIGURATION EXAMPLES
SMALL SIZE SYSTEM
MEDIUM SIZE SYSTEM
15
SPEAKERS LINES 100V
BM 9802 + BE 9808
BM 9804 + BE 9808
MX 9504
MS 1033
PC
BM 9804FM
VVFFFAS
bipolar cable 100 V input cable bus system cable
bipolar cable 100V input cable bus system cable
SPEAKERS LINES 100V
BM 9802 + BE 9808
BM 9804 + BE 9808
UP 9502
UP 9501
UP 9504
MU 9186R
MS 1033
PC
BM 9804FM
VVFFFAS
UP 9501
SPARE AMP
DXT 9000 - CONFIGURATION EXAMPLES
LARGE SIZE SYSTEM
16
bipolar cable 100V input cable bus system cable redundant ethernet
SPEAKERS LINES 100V
SPEAKERS LINES 100V
BM 9802 + BE 9808
BM 9804 + BE 9808
UP 9502
UP 9501
UP 9502
MU 9186R
MS 1033
PC / BMS
BM 9804FM
VVFFFAS
UP 9501
SYSTEM 1
Audio input
SWITCH
SWITCH
BM 9802
BM 9804 BE 9808
UP 9502
UP 9504
MS 1033
UP 9501
SPARE AMP
SPARE AMP
SYSTEM 2
SWITCH
MU 9186R
SYSTEM 3
SWITCH
MU 9186R
To othersubsystem units
SYSTEM 4
SWITCH
MU 9186R
To othersubsystem units
DXT 7000MEDIUM SIZE APPLICATIONS
DXT 7000 is a sound system conceived to completely control and manage background music and paging, even for emergency and evacuation purposes.The system has been designed to fulfil all requirements of EN 54-16 and EN 60849 standard, and it is really scalable, suitable for a wide range of applications: up to 32 MU 7100EN can be linked together in order to get an extended system, including many paging stations and up to 256 loudspeaker lines / paging zones.The main unit can play all necessary evacuation and alarm messages previously stored into its built-in digital memory.
The whole signal path from fireman’s microphone to loudspeaker lines is completely and automatically monitored against faults.
PATH MONITORING
The line transformer interface override voltage output is used to activate the relay in case of the main amplifier is faulty.
SPARE AMPLIFIER CHANGE OVER BOARD
The 8 internal digital amplifiers are highly reliable and their efficiency is excellent (> 90%): that means less heat dissipation and smaller capacity required for unbreakable power supply sources (UPS) used in security applications.A digital Matrix 7x8 is configurable for several applications with routing to any output channel, supported by an efficient Digital Signal Processor (DSP) providing Band Parametric EQ, Filters, Delay circuit for line arrays, Compressor / Limiter and Level controls.A software utility is available for saving unit parameters to PC, updating unit firmware, virtual control activation and status indication.
17
MU 7100ENDIGITAL MATRIX DXT 7000
MU 7100 is the main unit of the RCF DXT 7000 system, which has been designed to fulfill all requirements of EN 54-16 and EN 60849 standard. The whole signal path from fireman’s microphone to loudspeaker lines is completely and automatically monitored against faults. All properties and functions of the system are specified with Windows® based DXT 7000 configuration software and are downloaded to ‘master’ unit through its USB port.
Main Features
• Up to 32 units can be linked together in order to get an extended the systems• Up to 256 loudspeaker lines and many paging stations• The 8 digital internal amplifiers are highly reliable and excellent efficiency• Small capacity requirement for unbreakable power supply sources (UPS) used in security applications• The main unit can play all necessary evacuation and alarm messages previously stored into its built-in
digital memory• Digital Matrix 7 x 8 is configurable for several applications with routing to any output channel• An automatic level control facility can be got by simply connecting an omnidirectional noise detection
microphone to the inputs• Efficient Digital Signal Processor (DSP): 5-Band Parametric EQ, High and Low Pass Filters, Compressor
/ Limiter, Level controls are provided• Delay circuit for line array speaker applications• Built-in WAV file message player (up to128 messages)
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapersw
1818
Certifications
• EN 54-16:2008 (CPR: 1438-CPR-0241).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065 :2002.
p/n 17170157
TECHNICAL SPECIFICATIONS
Analogue input 1÷7 sensitivity -40 ÷ + 6 dBuAnalogue input impedance 20 kΩ (bilanciato)System and local bus audio (balanced) S/PDIFDigital message signal format (WAV) + 6 dBu
Frequency response (– 1 dB)ris. 16 bit,
freq. camp. 32 kHzS/N ratio 20 Hz ÷ 20 kHzTHD+N @1W/1 kHz 96 dBAContinuous power @ 8 Ω all ch. driven < 1%THD
< 0,05%
Speaker output nominal impedance 8 x 80W RMSMains operating voltage 8 Ω
Mains type connector100-240VAC,
50-60 HzPower consumption (ac) Classe IPower factor at full load 40 ÷ 990 WMains fuses 5x20mm tipico 0,95Secondary operating voltage 2 x T3.15AOperating temperature – 5 ÷ +50 ºC
20 ÷ 90% RH non-condensing
Dimensions (w, h, d)485 mm, 86mm,
375 mmNet weight 8,4 kg
19
MT 7308 is suitable to control up to 8 additional power amplifiers and relevant speaker lines, according to EN 54-16 norm. It works connected to the MU 7100EN master system unit. When speaker lines drive high power loads, it could be convenient to optimize the system configuration by using one or more dedicated power amplifiers dimensioned according the loads involved.
MT 7308ENPOWER AMPLIFIER MANAGER
p/n 17170159
MU 7100EN
LT 7208EN
LT 7208 MIC/LINE INPUT
CONTROL OUTPUT
CONTROL INPUT
100-240V45-63Hz40-980W
SPEAKER OUTPUTS 80OHM/150W 24VDC 48VDC 2x7A
RS-232
SYSTEMOVERRIDE AUDIO OUT
LOCAL
LOCAL SYSTEM
CTRL 1 2 3 4 5 6 7
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 USB BUS BUS LINK
SR No
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 OUT IN IN
3,15T 3,15T
LOW IMPEDANCE INPUTSCH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 IN CTRL
IN
24VDCLINE 1 LINE 2 LINE 3
SPEAKER LINE OUTPUTS 50/70/100VLINE 4 LINE 5 LINE 6 LINE 7
SR No
LINE 8OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
Main Features
• Integrates external (constant voltage) amplifiers into the monitored DXT 7000EN voice evacuation system.• It is possible to use any professional single / multichannel amplifier equipped with a 0 ÷6 dBu balanced audio input and 50/70/100 V constant voltage output(s).• One or two MT 7308EN can be linked to each MU 7100EN main unit.• One unit can be used for up to eight external amplifiers (and its loudspeaker line monitoring).• Max. power for each external amplifier: 500 W.• Spare amplifier facility on dip-switch with automatic replacement of a faulty one.• Half 19” rack unit, so two MT 7308EN can be installed into 19” 1U rack.• PC configuration software and communication on local bus with host MU 7100EN
Certifications
• EN 54-16:2008 (CPR: 1438-CPR-0241).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065 :2002.
TECHNICAL SPECIFICATIONS
Input impedance 8 Ω
Output voltage 100 V (on request: 70 – 50 V)
Max. power (single output) 80 W
Dimensions (w, h, d) 483 mm, 88 mm, 382 mm (19” two-unit rack)
Net weight 13 kg
LT 7208ENLINE TRANSFORMER INTERFACE
The LT 7208EN unit has 8 internal transformers (80 W / each) to convert the 8 Ohm loudspeaker outputs of the MU 7100 central unit into constant voltage lines (100 - 70 - 50 V) for loudspeakers having transformers.The possible combinations are 8 x 80W, 4 x 160 W and 2 x 320W (or any combination from these).
Main Features
• The LT 7208EN line transformer interface allows you to link/ group the 8 amplifiers to increase the power of the speaker lines two, three or four times
• If the needed speaker line power is more than 80W, several outputs (in groups made of 2, 3 or 4) can be connected together (in parallel) in order to get locked groups for 160 W, 240 W or 320 W lines
• Output line voltage setting (50-70-100 V) is made by changing the output tapping of each transformer
• Includes also line specific 24V dc outputs for override relays (max. current: 1A / line)• Connection cable to MU 7100EN main unit 8 pcs. of ‘end of line’ unit, used when the loudspea-
ker line monitoring is provided• The ‘end of line’ unit shall be installed right at the end of the line, near the last installed loudspe-
aker
Certifications
• EN 54-16:2008 (CPR: 1438-CPR-0241).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE
(LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN
61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065 :2002.
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapers
20
MU 7100EN
LT 7208EN
LT 7208 MIC/LINE INPUT
CONTROL OUTPUT
CONTROL INPUT
100-240V45-63Hz40-980W
SPEAKER OUTPUTS 80OHM/150W 24VDC 48VDC 2x7A
RS-232
SYSTEMOVERRIDE AUDIO OUT
LOCAL
LOCAL SYSTEM
CTRL 1 2 3 4 5 6 7
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 USB BUS BUS LINK
SR No
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 OUT IN IN
3,15T 3,15T
LOW IMPEDANCE INPUTSCH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 IN CTRL
IN
24VDCLINE 1 LINE 2 LINE 3
SPEAKER LINE OUTPUTS 50/70/100VLINE 4 LINE 5 LINE 6 LINE 7
SR No
LINE 8OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
OVER-RIDE
p/n 17170156
21
Our class D amplifiers with selectable 70 – 100 V output per channel provide pro audio performance with double switching AC-DC power supply and transformer-less galvanic insulated speaker output. They are equipped with double input per channel, active full protections on amplifier and power supply, activity and status indicators, as well as stand-by, priority and fault remote commands.
They are equipped with volume knobs on front panel with disablement facility and characterized by a light-weight 1 U 19” rack enclosure. UP 8501, UP 8502 and UP 8504 are EN 54-16 certified only when combined with DXT 7000.
22
UP 8501UP 8502UP 8504DIGITAL POWER AMPLIFIERS
p/n 12135070
p/n 12135077
p/n 12135079
Certifications
• EN 54-16:2008 (CPR: 1438-CPR-0241).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065 :2002.
23
TECHNICAL SPECIFICATIONS
23
UP 8501
UP 8502
INPUT 2INPUT 1 PRIOR
elbasiD refiilpmANO / yB-dnatS
sutatS daolrevO
- +
GAIN A
IN 2A
FFO
SPEAKER LINE OUTPUT48 V dc - 15 A max
UP4x125W POWER AMPLIFIER
DNG
115/230V - 50/60Hz - 800 W max VOL GND IN
V07 AV001
a
MAX OUTPUT POWER 125 W RMSMINIMUM LOAD IMPEDANCE70 V (39 ) - 100 v (80 )-+
MADE IN ITALY
AC VOLTAGE SELECTOR AND FUSE INSIDE, REFER TO INSTRUCTION MANUAL
Serial No.:
rtlF A
retsaM
emuloVFFO
b
Test>1+2
RemVol TestGND1 > 2a aDNGb b/LGND R
INPUT 2INPUT 1 PRIORVOL GND IN
Test>1+2
RemVol TestGND1 > 2a aDNGb b/LGND R
INPUT 2INPUT 1 PRIORVOL GND IN INPUT 2INPUT 1 PRIORVOL GND IN
- +
GAIN C
IN 2C
- +
GAIN B
- +
GAIN D
IN 2D
FFOV07 B
V001rtlF B
V07 CrtlF CV07 DrtlF D
a ba b a b
AMP C AMP B A PMAD PMA
OFF100V
OFF100V
UP 8504
INPUT 2INPUT 1 PRIOR
elbasiD refiilpmANO / yB-dnatS
sutatS daolrevO
- +
GAIN A
IN 2A
FFO
SPEAKER LINE OUTPUT48 V dc - 15 A max
UP4x125W POWER AMPLIFIER
DNG
115/230V - 50/60Hz - 800 W max VOL GND IN
V07 AV001
a
MAX OUTPUT POWER 125 W RMSMINIMUM LOAD IMPEDANCE70 V (39 ) - 100 v (80 )-+
MADE IN ITALY
AC VOLTAGE SELECTOR AND FUSE INSIDE, REFER TO INSTRUCTION MANUAL
Serial No.:
rtlF A
retsaM
emuloVFFO
b
Test>1+2
RemVol TestGND1 > 2a aDNGb b/LGND R
INPUT 2INPUT 1 PRIORVOL GND IN
Test>1+2
RemVol TestGND1 > 2a aDNGb b/LGND R
INPUT 2INPUT 1 PRIORVOL GND IN INPUT 2INPUT 1 PRIORVOL GND IN
- +
GAIN C
IN 2C
- +
GAIN B
- +
GAIN D
IN 2D
FFOV07 B
V001rtlF B
V07 CrtlF CV07 DrtlF D
a ba b a b
AMP C AMP B A PMAD PMA
OFF100V
OFF100V
INPUT 2INPUT 1 PRIOR
elbasiD refiilpmANO / yB-dnatS
sutatS daolrevO
- +
GAIN A
IN 2A
FFO
SPEAKER LINE OUTPUT48 V dc - 15 A max
UP4x125W POWER AMPLIFIER
DNG
115/230V - 50/60Hz - 800 W max VOL GND IN
V07 AV001
a
MAX OUTPUT POWER 125 W RMSMINIMUM LOAD IMPEDANCE70 V (39 ) - 100 v (80 )-+
MADE IN ITALY
AC VOLTAGE SELECTOR AND FUSE INSIDE, REFER TO INSTRUCTION MANUAL
Serial No.:
rtlF A
retsaM
emuloVFFO
b
Test>1+2
RemVol TestGND1 > 2a aDNGb b/LGND R
INPUT 2INPUT 1 PRIORVOL GND IN
Test>1+2
RemVol TestGND1 > 2a aDNGb b/LGND R
INPUT 2INPUT 1 PRIORVOL GND IN INPUT 2INPUT 1 PRIORVOL GND IN
- +
GAIN C
IN 2C
- +
GAIN B
- +
GAIN D
IN 2D
FFOV07 B
V001rtlF B
V07 CrtlF CV07 DrtlF D
a ba b a b
AMP C AMP B A PMAD PMA
OFF100V
OFF100V
UP 8501 UP 8502 UP 8504No. Channels x output power (rms) 1 x 500 W 2 x 250 W 4 x 125 WFrequency response 40 HZ ÷ 16 kHzBand-pass filter (12 db / oct) 200 HZ ÷ 8 kHzThd and noise (at max. Power) MAX. 0.3%
Signal / noise ratio (iec-a) 86 DBInput 1 sensitivity 0 dBu (775 mV, max. 7 V)Input 2 sensitivity 0 ÷ –20 dBu (775 ÷ 78 mV, max. 7 V)In test sensitivity 0 dBu (775 mV)Input impedance 10 kΩMinimum load impedance of each 70 v line 10 Ω 20 Ω 40 ΩMinimum load impedance of each 100 v line 20 Ω 40 Ω 80 ΩOver signal limiter overload, short circuit, overheating
Operating voltage115 – 230V c.a. ±10%, 50 – 60 Hz (internal voltage selector)
Batteries: 48 V d.c. ±10%Power consumption, ac stand-by 3 WPower consumption, disabled amp. 13 W 15 W 20 WPower consumption, no input signal 25 W 36 W 50 WPower consumption, musical signal 160 WPower consumption, max. Output power 650 WPower consumption, max. Overload 800 W
Operating temperature 0 ÷ 55 °C; Humidity: max 90%Dimensions (w, h, d) 482 mm, 44 mm, 375 mm (1 rack unit 19”)Net weight 5.2 KG 5.4 KG 5.6 KG
BM 7608BM 7608DBM 7608DFMBM 7624DMICROPHONE CONSOLEPaging microphone set monitored according to EN 54-16 norm, with metal body and an high intelligibility microphone mounted on a 250mm gooseneck.
The 8 configurable buttons can be programmed to send live microphone announcements in specific zones or groups of zones.
There are dedicated buttons to access the emergency operation/functions, in order to send pre-recorded security messages or microphone announcements.
One input on RCA stereo connector is available for the direct connection of a program source (i.e. CD player), to be sent through the same audio cannel where the console is connected when paging is not in progress.
The console is powered through the same system bus or through a local optional power supply. High intelligibility microphone with polyurethane foam wind screen. The connection to the MU 7100EN master unit can be made by using a CAT 5 cable or a J-Type 4 twisted pair cable (es. Fire resistant model RCF CJ 428E) .
24
Applications
• Halls• Schools• Malls• Hospitals• Train stations• Hotels
Main Features
• Modern design• Monitored microphone• Audio input (3.5 mm TRS jack connector) for an external device• Up to 32 paging microphones in the entire system, up to 8 for each local bus• 2 data bus ports for redundant systems• Connections to system / local buses according to the EIA/TIA-568B standard (CAT 5/6/7 wiring)• Flexible gooseneck microphone• 8 zone / function buttons• BM 7608D, BM 7608DFM, BM 7624D: Backlit LCD (menu based user interface)• BM 7608D, BM 7608DFM, BM 7624D: Numeric keyboard• BM 7608D, BM 7608DFM, BM 7624D: Input selection and volume control through menu
Certifications
• EN 54-16:2008 (CPR: 1438-CPR-0241).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065 :2002.
BM 7608
BM 7608DFM BM 7624D
BM 7608D
p/n 14322014
p/n 14322018
p/n 14322015
p/n 14322016
TECHNICAL SPECIFICATIONS
BM 7608 - BM 7608D BM 7608DFM - BM 7624D
Frequency response (-3 db)200-17 000 Hz (mic)50-17 000 Hz (aux)
200-17 000 Hz (mic)50-17 000 Hz (aux)
Audio input (aux) -14 ÷ 0dB (adjustable) -14 ÷ 0 dB (adjustable)
Thd + n 1 khz <0,1% <0,1%
Connectors RJ 45 RJ 45
Audio output 3,5mm TRS connector 3,5 mm TRS connector
EXT. CONTROL removable screw terminals 3 pin removable screw terminals 3 pin
p/n 17170140SV 7982REMOTE PROGRAMME SELECTORAND LEVEL CONTROL DEVICE
Used as local sound control device. It controls a zone group volume and operates as program selector. Connection to local or system bus by using CAT5/6 cabling. To be wall mounted by using with accessories provided.
p/n 17170141
Used for connection and routing of a local program source (mono signal, 3.5 mm balanced stereo plug). 3 function keys can be individually programmed, for example, to route local program source to desired loudspeaker lines.To be wall mounted by using the accessories provided.
LI 7903REMOTE LOCAL INPUT / CONTROL DEVICE
The SI 7120 board is a system monitoring module for the DXT 7000 system.It monitors the operation condition of 2 lines coming from the fire alarm system to DXT 7000.If a line is open or shorted, the SI 7120 board will detect the fault and activate a command.
EN 54-16:2008 (CPR: 1438-CPR-0241)
A RO 7102 board can be directly connected to a pair of MU 7100EN control outputs. It converts the 2 MU 7100EN open-collector ‘control outputs’ to 2 dry closing contacts that can be used as commands or external devices. It also has resistors needed for monitored alarm lines.
EN 54-16:2008 (CPR: 1438-CPR-0241)
The board has 2 main 70-100V loudspeaker line inputs, spare amplifier input and output, 2 relays. AC 7212 terminal shall be directly connected to a pair of LT 7208EN loudspeaker 50-70-100 V outputs. The LT 7208EN override voltage output is used to activate the AC 7212 relay in case of the main amplifier is faulty and switch the spare amplifier output to the respective loudspeaker line.
EN 54-16:2008(CPR: 1438-CPR-0241)
SI 7120MONITORED LOGICAL INPUT BOARD FOR MU 7100ENp/n 17170153
RO 7102DRY OUTPUT CONTACT BOARD FOR MU 7100ENp/n 17170151
AC 7212SPARE AMPLIFIER CHANGE-OVER BOARD FOR LT 7208ENp/n 17170152
25
bipolar cable 100 V input cable bus system cable
MQ 50 C
MS 1033BM 7608D
MU 7100
LT 7802
MQ 50
MQ 50 C
VVFF
SV 7982 LI 7903
DXT 7000 - SMALL SIZE SYSTEMS
bipolar cable 100 V input cable bus system cable
MQ 50 C
MS 1033BM 7608D
MU 7100
LT 7802
MQ 50
MQ 50 C
MS 1033BM 7608D
MU 7100
LT 7802
MQ 50
MQ 50 C
DXT 7000 - MEDIUM SIZE SYSTEMS
MEDIUM SIZE SYSTEM
DXT 7000 - CONFIGURATION EXAMPLES
SMALL SIZE SYSTEM
26
LARGE SIZE SYSTEMDXT 7000 - LARGE SIZE SYSTEMS
DXT 7000 - CONFIGURATION EXAMPLES
27
POWER SUPPLIES and SYSTEMS ACCESSORIESFOR DXT9000 and DXT7000
TECHNICAL SPECIFICATIONS PS 4048 PS 6048
Rated output voltage 48 V DC 48 V DC
Output voltage at half load (25°c): 54.4 V dc ±0.5% 54.4 V dc ±0.5%
Nominal output current: 8 A 12 A
Nominal power 400 W 7200 W (Jumper set to 75’), 4800 W (Jumper set to 50)
Battery voltage 48 V DC (4 x 12 V) 48 V DC (4 x 12 V)
Authorized battery capacity 38 ÷ 140 Ah 86 ÷ 225 Ah (Jumper set to 75’), 65 ÷ 225 Ah (Jumper set to 50)
PS 6048 and PS 4048 are power supply units suitable to get continuity power for EN 54-16 systems units like DXT 9000 and DXT 7000, and relevant complementary devices in case of mains power supply interruptions. They include recharging and monitoring functions for the lead-acid batteries connected to them and are EN 54-16 certified. They must be equipped with batteries with suitable capacity, dimensioned according to the system power absorption and to the evacuation requirements. According to EN 54-16 standard, PS 6048 and PS4048 shall be installed into the same rack cabinet where there is the audio system with emergency purposes (or a system part) to which it is connected.
EN 54-4: 1997 +A1: 2002 +A2: 2006 (CPR: 0333-CPD-075370-1) for PS 4048EN 54-4: 1997 +A1: 2002 +A2: 2006 (CPR: 0333-CPD-075383-2) for PS 6048
PS 404848 VCC POWER SUPPLY ACCORDING TO EN 54-4
PS 604848 VCC POWER SUPPLY ACCORDING TO EN 54-4
Fire resistant cables for data with conductor thickness of 0.8 mm shielded. Color of the outer cover Red. Inner conductors colors Yellow, Grey, Blue, Red. Certification VDE 0815, DIN 4102, EN 50200 PH 120, EN 60332-1-2, EN61034-2, FIPEC (EN) Coils of 200 m. The construction process consists in conductors isolation using a layer of silicon rubber. The core is then separated into two twisted pairs together and screens, subsequently the outer sheath is applied with a process of compression seeds.
CJ 228EFIRE RESISTANT DATA CABLE
p/n 14380017 p/n 14380021
CJ 428EFIRE RESISTANT DATA CABLE
28
p/n 17170158 p/n 17170169
DXT 3000SCALABLE COMPACT SOLUTION
DXT 3000 is a wall-mounting intelligent evacuation system dedicated to small and medium size applications, where an EN54-16 system is required. It includes a digital DSP-based master unit equipped with up to 6 RCF Class D+ power amplifiers, able to provide up to 250W on 100V or 70V speaker lines.
A spare power amplifier with automatic replacement of a faulty unit is configurable too.MX 3250 hosts batteries and the necessary EN54-4 circuitry for the DC back-up. Furthermore it offers inputs, controls and pre-recorded messages to get a real plug & play solution.
Monitored paging consoles and 6 button extensions allow to complete the installation by adding live announcements. Local single-button paging microphones and background music programs can be implemented as well.The system can be expanded to fit with middle size applications, centralized or distributed connecting up to eight using a dedicated interlink accessory board.DXT 3000 system has been designed to be wired by using very convenient fire-rated J-TYPE cables for paging console and interlink connections.
BM 3804, a low power consumption monitored console, suitable for selective emergency paging and message triggering.
MONITORED PAGING CONSOLE
Digital DSP-based master unit equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers.
ADVANCED TECHNOLOGY
29
30
MX 3500 is the master unit of the evacuation system DXT 3000, dedicated to small and medium size applications, with double power compared to MX 3250. As the smaller model, it includes a digital DSP-based master unit equipped with up to 6 RCF Class D+ power amplifiers, able to provide up to 500W on 100V or 70V speaker lines. Furthermore it offers inputs, controls and pre-recorded messages to get a real plug & play solution, included a music source easily accessible from the front panel.All other features, included scalability through IE 3008, are the same of MX 3250.
Main Features
• DSP-based Master Unit• Equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers.• A/B speakers lines• Spare power amplifier with automatic replacement• Internal power supply with battery charger and space for batteries.• Emergency messages on monitored SD card.
Applications
• Halls• Schools• Shopping Centers• Offices• Public buildings
MX 3500/2MX 3500/4MX 3500/6MASTER UNITS WITH AMPLIFIERS
Certifications
• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.• EN 54-16:2008 / EN 54-4: 1997 +A1: 2002 +A2: 2006: certification in progress.
p/n 12100009
p/n 12100010
p/n 12100011
Accessories• Rack lateral support
Applications
• Halls• Schools• Shopping Centers• Offices• Public buildings
31
OUTPUT POWER Up to 500W distributed on 2, 4 or 6 zones (max 250W per zone)
Frequency response: 80 ÷ 16.000 Hz (± 1 dB)
Distortion (THD + N): < 0,3% @ 1 kHz
Output voltage to speaker lines: 100 V, 70 V
Signal / noise ratio: > 80 dBA
Operating voltage (mains): 115/230V +10/-15% 50/60Hz Internal setting
Operating voltage (batteries): 48Vdc (4x12V) Ri max= 440mΩ
Nominal Load Rl=20/10Ω ; Cl=10nF
Mains Input Power 700W max.
Battery Input Current 15.3 A max
Battery Capacity 4 x 12 Ah (int. setting)
Ambient operating temperature 40°C max
Max. number of daisy-chained BM 3804 paging microphones
4
Simultaneous audio channels 3
Paging microphone cable CAT 6 FTP or J-type (RCF)
Integrated audio player: SD card, USB pen drive, 3.5mm jack aux input
Dimensions (w, h, d) 430 mm, 620 mm, 180 mm (19” rack – 14 units)
TECHNICAL SPECIFICATIONS
MX 3500 is equipped with an integrated audio source, directly accessible from the unit front panel and connected to the BGM input.
The source, which supports mp3 files only, includes an SD card reader, a USB pen drive reader and an auxiliary input on 3.5 mm jack.
In addition to the inputs, the front panel offers also the basic controls for track selection and the pause command.
Moreover, a monitor output is available on 3.5 mm jack, and allows checking the audio content before send it to the speakers lines. After control, audio shall be activated manually using the AUDIO ON button (also indicated by LED).
Accessories• Rack lateral support
MASTER UNITS WITH AMPLIFIERSMX 3250 is the master unit of the DXT 3000 evacuation system, dedicated to small and medium size applications, where an EN54-16 system is required.It includes a digital DSP-based master unit equipped with 2, 4 or 6 RCF Class D+ power amplifiers, able to provide up to 250W on 100V or 70V speaker lines. A spare power amplifier with automatic replacement of a faulty unit is configurable too. It hosts batteries and the necessary EN54-4 circuitry for the DC back-up.Furthermore it offers inputs, controls and pre-recorded messages to get a real plug & play solution.The system can be completed with BM 3804 monitored paging consoles and 6 BE 3806 button extensions, allowing to complete the installation by adding live announcements. Local single-button paging consoles (not monitored) BM 3022 and background music programs can be implemented as well.DXT 3000 system has been designed to be wired by using very convenient fire-rated J-TYPE cables for paging console and interlink connections.
Main Features
• DSP-based Master Unit• Equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers.• Spare power amplifier with automatic replacement• Internal power supply with battery charger and space for batteries.• Emergency messages on monitored SD card.
Applications
• Halls• Schools• Shopping Centers• Offices• Public buildings
32
Accessories• Rack lateral support
MX 3250/2MX 3250/4MX 3250/6
Certifications
• EN 54-16:2008 / EN 54-4: 1997 +A1: 2002 +A2: 2006 (CPR: 0068-CPR-007/2015).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
p/n 17170177
p/n 17170183
p/n 17170184
Applications
• Halls• Schools• Shopping Centers• Offices• Public buildings
Accessories• Rack lateral support
OUTPUT POWER Up to 250W distributed on 2, 4 or 6 zones
Frequency response: 50 ÷ 16.000 Hz (± 1 dB)
Distortion (THD + N): < 0,3% @ 1 kHz
Output voltage to speaker lines: 100 V, 70 V
Signal / noise ratio: > 80 dBA
Operating voltage (mains): 115/230V +10/-15% 50/60Hz Internal setting
Operating voltage (batteries): 24Vdc (2x12V) Ri max= 220mΩ
Nominal Load Rl=40/20Ω ; Cl=5nF
Mains Input Power 400W max.
Battery Input Current 18A max
Battery Capacity 7-12 -18 Ah (int. setting)
Ambient operating temperature 40°C max
Max. number of daisy-chained BM 3804 paging microphones 4
Simultaneous audio channels 3
Paging microphone cable CAT 6 FTP or J-type (RCF)
Dimensions (w, h, d) 430 mm, 530 mm, 180 mm (19” rack – 12 units)
TECHNICAL SPECIFICATIONS
33
20 Hz resonator, with an impedance of 200 Ohm at the resonance frequency. Installed after the last speaker, it allows to accurately monitor speakers lines integrity. Suitable for DXT3000 and DXT9000 systems.
EOL 3-9END OF LINE
p/n 17170176AC BAT 18BATTERIES
p/n 13360317
Pair of sealed lead acid batteries (12V - 18Ah each.)
IE 3008DXT 3000 INTERLINK BOARD
p/n 12399015
It allows connecting up to 8 MX 3250 units, in a MASTER/SLAVE configuration. The system units communicate over 2 eight poles euroblock connectors, in order to guarantee a fully redundant network. Local paging for non-emergency purpose is also possible.
MG 3006MONITORED GPI BOARD
p/n 13360344
MG 3006 is an additional monitored GPI board for the MX 3250 main unit (DXT 3000 system). It allows to monitor emergency system general purpose inputs (GPI), and detect (and report) any open line or short circuit along the path between DXT 3000 and other alarm devices, such as alarm buttons.MG 3006 is installed inside the MX 3250 cabinet, and powered (24V) directly by the system.
34
BE 3806DESKTOP PAGING MICROPHONESBM 3804 is a desktop paging microphone exclusively dedicated for the RCF DXT 3000 system. It can be directly connected to the MX 3250 main unit through a fourpair J-type fire-rated cable.Up to four interlocked BM 3804 paging microphones can be linked (daisy-chained) to the line. The first BM 3804 paging microphone (of the line) is directly powered by the MX 3250 main unit, while the second, the third and the fourth need 24 V dc adapters (500 mA, i.e. RCF AC AD 2405, optional).BM 3804 is also available in Firemen version, hosted in a closed wall mounting red metal cabinet, with glass door to access console status. This version is equipped with dynamic microphone, with incorporated push to talk button, and can be used in combination with a BE 3806 (also installed inside the cabinet), to improve selective calls efficiency.BE 3804 can be directly connected to the MX 3250 main unit through a fourpair J-type fire-rated cable.
BM 3804 FMBM 3804
Main Features
• Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface.
• Die-cast metal enclosure with 420 mm gooseneck.• Pre-amplified hyper-cardioid hi-quality microphone with integrated
compressor and limiter to get intelligible announcements even in critical ambients.• Programmable function keys for announcements or commands.• Power supply voltage from the Flexicomm BUS or from 24V DC local input.• Interactive LCD backlit display associated to an encoder that indicates
which operations are active and recovers system information.• Alert and evacuation indications.• Pre-recorded message activation.• 5m connecting cable (with RJ 45 plugs) included.• Dedicated “chime” key.
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapers
Certifications
• EN 54-16:2008 (CPR: 0068-CPR-007/2015).• CE in compliance with EU directives 2004/108/CE (EMC) and 2006/95/CE (LVD).• EMC according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1.• LVD according to IEC EN 60065:2002.
p/n 14380028
p/n 14380036
p/n 14380037
Applications
• Shopping centers• Hospitals• Railway stations• Airports• Halls• Schools• Stadiums• Skyscrapers
TECHNICAL SPECIFICATIONS BM 3804 BM 3804 FM
Microphone type: electret dynamic
Polar patter: cardioid omnidirectional
Output impedance: 470 Ω (1 kHz) 500 Ω ± 30% (1 kHz)
Microphone sensitivity: – 65 dB ± 3 dB (0 dB=1V/μbar, 1 kHz) – 70 dB ± 3 dB (0 dB=1V/μbar, 1 kHz)
Frequency response: 50 Hz ÷ 18 kHz (– 3 dB) 300 Hz ÷ 6 kHz (– 3 dB)
Power supply: 24 V dc (MX 3250 or RCF AC AD2405 external adapter)
24 V dc (MX 3250
Dimensions: 128 x 39 x 203 mm (without gooseneck) 360 x 360 x 129 mm
Gooseneck length: 445.5 mm -
Net weight: 1.2 kg (2.7 lbs) 6.9 kg (15.2 lbs)
SPECIFICATIONS BM 3806
Power supply: through the BM 3804 paging microphone
Dimensions: 78 mm x 39 mm x 203 mm
Net weight: 0.7 kg (1.6 lbs)
TECHNICAL SPECIFICATIONS
277
330
125
80
277 125
80
128
452
(mm)203
39
128
452
1.100 g
203
39
(mm)
203
7839
483
177
387
483
132
376
PU 5218
483
44 377
483
88 382
178
63 158
(mm)
DR 5301 Data Repeater
178
63 158
(mm)
DR 5301-P Data Repeater for Power Bridge
PB 5310 Power Bridge
483
88 375
MU 5100 -1 MT 5708 -2 BM 5804 -3
LT 7208 - 11
BM 5802 -5
BM 7802 - 12
PU 5218 -7
BM 7801FM - 11
BE 5808 -6
DR 5301 - 8 MU 7100 -10PB 5310 - 9
BM 3804 BM 3804FM BE 3806
bipolar cable 100V input cable
MS 1033
BM 3022
ZONE 1
A
B
A
B
BM 3804
ZONE 2
GENERALALARM
1
1
2 nn
1 2 n
Emergency buttonInternal resistor 470 Ohm
End of line resistor 4.7 kOhm
CONFIGURATION WITH MG 3006
bipolar cable 100V input cable
MS 1033
BM 3022
ZONE 1
A
B
A
B
BM 3804
ZONE 2
GENERALALARM
1
1
2 nn
1 2 n
Emergency buttonInternal resistor 470 Ohm
End of line resistor 4.7 kOhm
bipolar cable 100V input cable
MS 1033
BM 3022
ZONE 1
A
B
A
B
BM 3804
ZONE 2
GENERALALARM
1
1
2 nn
1 2 n
Emergency buttonInternal resistor 470 Ohm
End of line resistor 4.7 kOhm
bipolar cable 100V input cable
MS 1033
BM 3022
ZONE 1
A
B
A
B
BM 3804
ZONE 2
GENERALALARM
1
1
2 nn
1 2 n
Emergency buttonInternal resistor 470 Ohm
End of line resistor 4.7 kOhm
35
DXT 3000 - BASIC CONFIGURATION
bipolar cable 100 V input cable
MS 1033
BM 3022
ZONE 1
A
B
A
B
BM 3804
VVFF
ZONE 2
EXTENDED CONFIGURATION
DXT 3000 - EXTENDED CONFIGURATION
bipolar cable 100 V input cable bus system cable
MS 1033
BM 3022
BM 3804BE 3806
VVFF
BM 3022
ZONE 1
A
B
ZONE 2
A
B
A
B
ZONE 4
A
B
ZONE 3
DXT 3000 - CONFIGURATION EXAMPLES
BASIC CONFIGURATION
36
37
38
PL 82EN2 WAYS CEILING SPEAKER FIRE DOME
p/n 13100009 Main Features
• Speaker for transmitting alarm voice messages with high intelligibility and background music.
• Power (selectable) at 100V: 20 W – 10 W – 5 W.• 8” diameter wide band loudspeaker.• Steel protection Fire Dome, terminal strip in ceramic material
for connecting flameproof input and output cables, thermal fuse, suitable internal wiring.
• Structure, front grille, and protection cap in steel, RAL 9016 White.
The PL 82EN is a 2 ways ceiling speaker featuring a flameproof steel bottom designed for recess installation in false ceilings or panels. It is especially suitable for broadcasting alarm messages thanks to highly intelligible sound reproduction and it is resistant to the high temperatures reached during fires. The terminal connection boards are in ceramic material for input and output flameproof cables. A thermal fuse protects the integrity of the line in case of heat affecting the speaker. Ground screw. Cables inside speaker made using flameproof leads.
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 20 W – 10 W – 5 W
Input impedance (1 kHz) 1.67 kΩ (20 W) – 3.33 kΩ (10 W) – 6.67 kΩ (5 W)
Frequency response 130 Hz ÷ 20 kHz (–10 dB)
Sensitivity 94 dB (1 W, 1 m), 82 dB (1 W, 4 m)
Sound pressure level 88 dB (1 W, 1 m)
Transducer 8”
Material Steel
ColourBody and grille: white RAL 9016.
Dome: red
Connector Ceramic terminal
IP protection grade IP 40
Dimensions ø 270 mm (10.63”), h: 127 mm (5”)
Net weight 1,8 kg (3.6 lb)
MODELLO SCALA
PL 82EN 1:2
ø 272 mm
120
mm
147
mm
ø 236 mm
PL 70ENCEILING SPEAKER FIRE DOMEThe PL 70EN is a ceiling speaker featuring a flameproof steel bottom designed for recess installation in false ceilings or panels. It is especially suitable for broadcasting alarm messages thanks to highly intelligible sound reproduction and it is resistant to high temperatures that are reached during fires. The terminal connection boards are in ceramic material for input and output flameproof cables. A thermal fuse protects the integrity of the line in case of heat affecting the speaker. Ground screw. Cables inside speaker made using flameproof leads.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0487/W)• Speaker for transmitting alarm voice messages with high
intelligibility and background music• Music power/RMS: 24/6W• 6” diameter dual cone wide band loudspeaker• Low impedance (8 Ω) or 100V• Steel protection Fire Dome, terminal strip in ceramic material
for connecting flameproof input and output cables, thermal fuse, suitable internal wiring
• Structure, front grille, and protection cap in steel, RAL 9003 White
Input voltage 100 V – (70 V)
Power 6 W – 3 W – 1.5 W – 0.75 W
Input impedance 1.67 kΩ (6 W) – 3.33 kΩ (3 W) - 6.67 kΩ (1.5 W) – 13.33 kΩ (0.75 W)
Frequency response 145 Hz ÷ 20 kHz (–10 dB)
Sensitivity 95 dB (1 W, 1 m)
Sound pressure level 103 dB (6 W, 1 m), 91 dB (6 W, 4 m)
Transducer 6” dual-cone
Material Steel
ColourBody and grille: white RAL 9003
Dome: red
Connector Ceramic terminal
IP protection grade IP 40
Dimensions ø 230 mm (9.1”), H: 127 mm (5”)
Net weight 2 kg (4.4 lb)
Notes False ceiling cutout size: ø 205 mm (8.1”)
TECHNICAL SPECIFICATIONS
39
p/n 13133065
MODELLO SCALA
PL 70EN 1:2
ø 230 mm
124
mm
137
mm
ø 199 mm
PL 68ENCEILING SPEAKER WITH FIRE DOME
The PL 68EN is a ceiling speaker featuring a flameproof steel bottom designed for recess installation in false ceilings or panels. It is especially suitable for broadcasting alarm messages thanks to highly intelligible sound reproduction and is resistant to the high temperatures reached during fires. The terminal connection boards are in ceramic material for input and output flameproof cables. A thermal fuse, protects the integrity of the line in case of heat affecting the speaker. Ground screw. Cables inside speaker made using flameproof leads.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0486/W)• Speaker for transmitting alarm voice messages with high
intelligibility and background music• Power (selectable) at 100V: 6 W – 3 W – 1.5 W (power values
are halved at 70 V)• 6” diameter dual cone wide band loudspeaker• Steel protection Fire Dome, terminal strip in ceramic material
for connecting flameproof input and output cables, thermal fuse, suitable internal wiring
• Structure, front grille, and protection cap in steel, RAL 9003 White
Input voltage 100 V – (70 V)
Power 6 W – 3 W – 1.5 W – 0.75 W
Input impedance 1.67 kΩ (6 W) – 3.33 kΩ (3 W) - 6.67 kΩ (1.5 W) – 13.33 kΩ (0.75 W)
Frequency response 130 Hz ÷ 20 kHz (–10 dB)
Sensitivity 94 dB (1 W, 1 m), 82 dB (1 W, 4 m)
Sound pressure level 102 dB (6 W, 1 m), 90 dB (6 W, 4 m)
Transducer 6” dual-cone
Material Steel
ColourBody and grille: white RAL 9003
Dome: red
Connector Ceramic terminal
IP protection grade IP 40
Dimensions ø 220 mm (8.6”), H: 96 mm (3.8”)
Net weight 1,1 kg (2.4 lb)
Notes False ceiling cutout size: ø 200 mm (7.9”)
TECHNICAL SPECIFICATIONS
40
p/n 13133082
MODELLO SCALA
PL 68EN 1:2
ø 220 mm
96 m
m
90.7
mm
2.4
mm
ø 180 mm
41
PL 50ENCEILING SPEAKER WITH FIRE DOME
p/n 13100007 Main Features
• Speaker for transmitting alarm voice messages with high intelligibility and background music
• Power (selectable) at 100V: 6 W – 3 W – 1.5 W – 0,75W.• 5” diameter wide band loudspeaker.• Steel protection Fire Dome, terminal strip in ceramic material
for connecting flameproof input and output cables, thermal fuse, suitable internal wiring.
• Structure, front grille, and protection cap in steel, RAL 9016 White.
The PL 50EN is a ceiling speaker featuring a flameproof steel bottom designed for recess installation in false ceilings or panels. It is especially suitable for broadcasting alarm messages thanks to highly intelligible sound reproduction and is resistant to the high temperatures reached during fires. The terminal connection boards are in ceramic material for input and output flameproof cables. A thermal fuse, protects the integrity of the line in case of heat affecting the speaker. Ground screw. Cables inside speaker made using flameproof leads.
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 6 W – 3 W – 1.5 W
Input impedance 1.67 kΩ (6 W) – 3.33 kΩ (3 W) – 6.67 kΩ (1.5 W)
Frequency response 130 Hz ÷ 15 kHz (–10 dB)
Sensitivity 94 dB (1 W, 1 m)
Sound pressure level 100 dB (6 W, 1 m)
Transducer 5”
Material Steel
ColourBody and grille: white RAL 9016
Dome: red
Connector Ceramic terminal
IP protection grade IP 40
Dimensions ø 180 mm (7.1”), H: 135 mm (5.3”)
Net weight 1,45 kg (3.2 lb)
Notes False ceiling cutout size: ø 200 mm (7.9”)
MODELLO SCALA
PL 50EN 1:2
ø 181 mm
123
mm
136
mm
ø 160 mm
42
PLP 50ENCEILING SPEAKER WITH PLASTIC FIRE DOME
p/n 13100008
The PLP 50EN is a ceiling speaker featuring a flameproof plastic bottom designed for recess installation in false ceilings or panels. It is especially suitable for broadcasting alarm messages thanks to highly intelligible sound reproduction and is resistant to the high temperatures reached during fires. The terminal connection boards are in ceramic material for input and output flameproof cables. A thermal fuse, protects the integrity of the line in case of heat affecting the speaker. Ground screw. Cables inside speaker made using flameproof leads.
Main Features
• Speaker for transmitting alarm voice messages with high intelligibility and background music.
• Power (selectable) at 100V: 6W - 3W - 1.5W• 5” diameter wide band loudspeaker.• Plastic protection Fire Dome, terminal strip in ceramic material
for connecting flameproof input and output cables, thermal fuse, suitable internal wiring.
• Structure, front grille, and protection cap in steel, RAL 9016 White.
TECHNICAL SPECIFICATIONS Input voltage 100 V – (70 V)
Power 6W - 3W - 1.5W
Input impedance (1 kHz) 1.67 kΩ (6 W) – 3.33 kΩ (3 W) - 6.67 kΩ (1.5 W)
Frequency response 130 Hz ÷ 15 kHz (–10 dB)
Sensitivity 93 dB (1 W, 1 m)
Sound pressure level 97 dB (6 W, 1 m)
Transducer 5”
MaterialGrille: steel
Dome: plastic
Colour White RAL 9016
Connector Ceramic terminal
IP protection grade IP 40
Dimensions ø 115 mm (6,9”)
Net weight 0,9 kg (3.2 lb)
MODELLO SCALA
PLP 50EN 1:2
ø 175 mm
66 m
m
71 m
m
ø 144 mm
DP 5ENUNIDIRECTIONAL SOUND PROJECTORDP 5EN is a 20W, EN 54-24 certified weatherproof sound projector.It is suitable for all those installations where high intelligibility for alarm messages broadcasting and great sound reproduction quality are required; moreover, thanks to its IP 65 protection grade, it can be installed both indoor and outdoor.A modern and endearing design makes it the perfect product for environments where projectors are intended also as architectural elements and contribute to improve global aesthetics.
Main Features
• EN 54-24:2008 certified (CPR: 0068-CPR-058/2014)• 5’’ full range speaker for alarm voice messages broadcasting
and high quality background music• ABS cabinet with steel mesh grille.• It can be installed both indoors and outdoors (IP 65 protection
grade).• Equipped with transformer for 100 V (/ 70 V) constant voltage
lines.• Internal power setting.• Ceramic screw terminal for connection.• Internal thermal fuse.• Color: white.
TECHNICAL SPECIFICATIONS Input voltage 100 V – (70 V)
Power 20 W - 10 W - 5 W - 2.5 W
Input impedance 500 Ω (20 W) - 1 kΩ (10 W) - 2 kΩ (5 W) - 4 kΩ (2.5 W)
Frequency response 100 Hz ÷ 20 kHz
Sensitivity 88 dB (1 W, 1 m), 76 dB (1 W, 4m)
Sound pressure level 101 dB (20 W, 1 m), 89 dB (20 W, 4 m)
Transducer 5” full range
MaterialBody: ABS
Grille: steel
Colour White
Connector Ceramic terminal
IP protection grade IP 65
Dimensions ø 180 mm (7.1’’), depth: 260 mm (10.2’’) (without bracket)
Net weight 2.6 kg (5.75 lb)
43
p/n 13133076
MODELLO SCALA
DP 5EN 1:2
176 mm
183
mm
334 mm
261 mm73 mm
147 mm
BD 5ENBIDIRECTIONAL SOUND PROJECTOR
BD 5EN is a 20 W weatherproof bidirectional EN 54-24 certified sound projector.It is suitable for all those installations where high intelligibility for alarm messages broadcasting and great sound reproduction quality are required; moreover, thanks to its IP 65 protection grade, it can be installed both indoor and outdoor.A modern and endearing design makes it the perfect product for environments where projectors are intended also as architectural elements contributing to improve global aesthetics.
Main Features
• EN 54-24:2008 certified (CPR: 0068-CPR-058/2014)• 2 x 5’’ full range speakers for alarm voice messages broadca-
sting and high quality background music• ABS cabinet with steel mesh grille.• It can be installed both indoors and outdoors (IP 65 protection
grade).• Equipped with transformer for 100 V (/ 70 V) constant voltage
lines.• Internal power setting.• Ceramic screw terminal for connection.• Internal thermal fuse.• Color: white.
Input voltage 100 V – (70 V)
Power 20 W - 10 W - 5 W - 2.5 W
Input impedance 500 Ω (20 W) - 1 kΩ (10 W) - 2 kΩ (5 W) - 4 kΩ (2.5 W)
Frequency response 60 Hz ÷ 20 kHz
Sensitivity 86 dB (1 W, 1 m), 74 dB (1 W, 4m)
Sound pressure level 99 dB (20 W, 1 m), 87 dB (20 W, 4 m)
Transducer 2 x 5” full range
MaterialBody: ABS
Grille: steel
Colour White
Connector Ceramic terminal
IP protection grade IP 65
Dimensions ø 180 mm (7.1’’), depth: 340 mm (13.4’’) (without bracket)
Net weight 3.6 kg (7.9 lb)
TECHNICAL SPECIFICATIONS
44
p/n 13133077
MODELLO SCALA
BD 5EN 1:2
176 mm
147 mm
183
mm
179
mm
332 mm
BS 5ENPENDANT SPEAKERBS 5EN is a 20W, EN 54-24 certified pendant speaker.It is suitable for all those installations where high intelligibility for alarm messages broadcasting and great sound reproduction quality are required; moreover, thanks to its IP 65 protection grade, it can be installed both indoor and outdoor.A modern and endearing design makes it the perfect product for environments where projectors are intended also as architectural elements and contribute to improve global aesthetics.
Main Features
• EN 54-24:2008 certified (CPR: 0068-CPR-058/2014)• 5’’ coaxial speaker for alarm voice messages broadcasting and
high quality background music.• 5 meters cable.• ABS cabinet with steel mesh grille.• It can be installed both indoors and outdoors (IP 65 protection
grade).• Equipped with transformer for 100 V (/ 70 V) constant voltage
lines.• Internal power setting.• Ceramic screw terminal for connection.• Internal thermal fuse.• Color: white.
Input voltage 100 V – (70 V)
Power 20 W - 10 W - 5 W - 2.5 W
Input impedance 500 Ω (20 W) - 1 kΩ (10 W) - 2 kΩ (5 W) - 4 kΩ (2.5 W)
Frequency response 80 Hz ÷ 20 kHz
Sensitivity 88 dB (1 W, 1 m), 76 dB (1 W, 4m)
Sound pressure level 101 dB (20 W, 1 m), 89 dB (20 W, 4 m)
Transducer 5’’coaxial with 20 mm dome tweeter
MaterialBody: ABS
Grille: steel
Colour White
Connector Ceramic terminal
IP protection grade IP 65
Dimensions ø 180 mm (7.1’’), depth: 260 mm (10.2’’)
Net weight 2.79 kg (6.15 lb)
TECHNICAL SPECIFICATIONS
45
p/n 13133078
MODELLO SCALA
BS 5EN 1:2
147
mm
176
mm
261 mm 5 m
DP 1420ENALUMINIUM SOUND PROJECTOR
The DP 1420EN sound projector is elegant and suitable for sound distribution in very large environments. These have a cylindrical fire protection steel body and an U bracket support in aluminum for the installation. The projector incorporates a 130 mm (5”) loudspeaker. It includes a transformer inside for the connection to (100 – 70 V) constant voltage lines. Thanks to its ceramic termination blocks (capable of withstanding temperatures in excess of 650° C/202 °F), its thermal fuse (threshold: 150 °C/ 302 °F) and its fire-resistant cable, the speaker does not allow fire to move to the audio system.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0485/W)• Unidirectional sound projector characterized by high acoustic
performance• Ceramic screw terminal for connection.• Internal thermal fuse.• IP 66 protection, suitable for outdoor use• It’s ideal for train stations, underground stations, car parks,
factories, warehouses, and PA systems in general• Continuous nominal power: 20/40 W ([100 V]: 20-10-5 W -
[70V]: 20-10-5 W)
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power20 W – 10 W – 5 W – 2.5 W (100 V)
20 W – 10 W – 5 W – 2.5 W – 1.25 W (70 V)
Input impedance 500 Ω (20 W) - 1 kΩ (10 W) - 2 kΩ (5 W) - 4 kΩ (2.5 W)
Frequency response 160 Hz ÷ 20 kHz (–10 dB)
Sensitivity 92 dB (1 W, 1 m)
Sound pressure level 105 dB (20 W, 1 m), 93 dB (20 W, 4 m)
Transducer 5’’ full range
MaterialBody: aluminium
Grille: stainless steel
Colour Light Grey RAL 7035
Connector Ceramic terminal
IP protection grade IP 66
Dimensions ø 146 mm (5.8’’), depth 200 mm (7.9’’)
Net weight 2.5 kg (5.5 lb)
46
p/n 13133071
MODELLO SCALA
DP 1420EN 1:2
200 mm
Ø 146 mm
156 mm
61 mm
Ø 7 mm
BD 2412ENALUMINIUM BIDIRECTIONAL SOUND PROJECTOR
BD 2412EN sound projector is elegant and suitable for sound distribution in very large environments. These have a cylindrical fire protection steel body and support for the installation. The projector incorporates two 130 mm (5”) loudspeaker.It includes a transformer inside for the connection to (100 – 70V) constant voltage lines. Thanks to its ceramic termination blocks (capable of withstanding temperatures in excess of 650° C/202 °F), its thermal fuse (threshold: 150 °C/ 302 °F) and its fire-resistant cable, the speaker does not allow fire to move to the audio system.
Main Features
• Bidirectional sound projector with double loudspeaker, cha-racterized by high acoustic performance, excellent design and compact dimensions
• Ceramic screw terminal for connection.• Internal thermal fuse.• IP 66 protection, suitable for outdoor use• It’s ideal for train stations, underground stations, car parks,
factories, warehouses, and PA systems in general• Continuous nominal power: 20/10/5 W ([100 V]
p/n 13133074
Input voltage 100 V – (70 V)
Power 20 W – 10 W – 5 W
Input impedance 500 Ω (20 W) – 1 kΩ (10 W) – 2 kΩ (5 W)
Frequency response 130 Hz ÷ 20 kHz (–10 dB)
Sensitivity 89 dB (1 W, 1 m)
Sound pressure level 102 dB (20 W, 1 m), 90 dB (20 W, 4 m)
Transducer 2 x 5’’ full range
MaterialBody: aluminium
Grille: stainless steel
Colour Light Grey RAL 7035
Connector Ceramic terminal
IP protection grade IP 66
Dimensions ø 146 mm (5.8’’), depth 184 mm (7.2’’)
Net weight 3.3 kg (7.26 lb)
TECHNICAL SPECIFICATIONS
47
MODELLO SCALA
BD 2412EN 1:2
184 mm
100 mm
Ø 146 mm
170 mm
Ø 5 mm
48
2 WAYS BASS REFLEX CABINET SPEAKERSCompact design and a wealth of mounting options make the RCF MR 52BEN / MR 52WEN a Compact 2-way loudspeakers ideal for use both for alarm and business music systems.The installation is fast and efficient using the accompanying adjustable mounting bracket. Connections are made with ceramic terminals. Wattage taps and voltage adjustments selectable by means of two rotary switches. The enclosure is constructed of high density, scratch resistant ABS and includes a protective steel grille and connection cover. Compliant with EN 54-24:2008 standard.
Main Features
• 2 ways bass reflex cabinet speakers characterized by high acoustic performance.
• Ceramic termination block, thermal fuse and internal fire-resistant cable.
• It’s ideal for both voice alarm and business music applications.• 4 power levels selectable plus 8 Ω option.
TECHNICAL SPECIFICATIONS
MR 52BENMR 52WEN
p/n 13100011 p/n 13100010
Input voltage 100 V – (70 V)
Power 30W - 15W - 7.5W - 3.75W
Input impedance (1 kHz) 333Ω (30 W) - 667Ω (15 W) - 1.33kΩ (3.75 W) - 2.67kΩ (7.5 W)
Frequency response 80 Hz ÷ 20 kHz (–10 dB)
Sensitivity 89 dB (1 W, 1 m)
Sound pressure level 104 dB (30 W, 1 m)
Transducer5’’ woofer1’’ tweeter
MaterialBody: ABS
Grille: steel
Colour Black (MR 52BEN) and white (MR 52WEN)
Connector Ceramic terminal
IP protection grade IP 40
Dimensions H 242 mm (9,5’’), L 192 mm (7,6’’), D 190 mm (7,5’’)
Net weight 2.75 kg (6.06 lb)
MODELLO SCALA
MR 52BEN - MR 52WEN 1:2
192 mm
190 mm 90.5 mm
37 mm
242
mm
CS 6520ENTWO-WAY COLUMN SPEAKERTwo-way speakers with very compact dimensions, the CS 6520EN features 4 extended-range speakers and a tweeter. This model utilizes a series of innovative technological solutions that guarantee highly intelligible reproduction of the vocal message. It’s complete with line transformer for directly connecting the speaker columns to 70 V or 100 V constant-voltage systems and, thanks to multiple sockets, permit selecting the power to be diffused from among various values. Thanks to IP 66 insulation, the column speakers can also be used outdoors. Usable in railway stations, subways, churches, factories, warehouses, PA systems in general.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0490/W)• Ideal for speech reproduction with high intelligibility in acou-
stically difficult environments, both indoors and outdoors, also suitable for music
• Music power/RMS: 40/20W• Four 3” mid-woofer speakers and one central 20mm tweeter• Weather-resistant construction IP 66 for use also outdoors,
sturdy hinged support in resin, stainless steel fasteners• Body in aluminium and front grille in steel bake-painted RAL
9003 White• Articulated support for wall mounting included
Input voltage 100 V – (70 V)
Power 20 W – 10 W – 5 W – 2.5 W (100 V) 20 W – 10 W – 5 W – 2.5 W – 1.25 W (70 V)
Input impedance 250 Ω (20 W) - 500 Ω (20 W) - 1 kΩ (10 W) - 2 kΩ (5 W) - 4 kΩ (2.5 W)
Frequency response 140 Hz ÷ 20 kHz (–10 dB)
Sensitivity 92 dB (1 W, 1 m), 80 dB (1 W, 4m)
Sound pressure level 105 dB (20 W, 1 m), 93 dB (20 W, 4 m)
Transducer 4 x 3” mid-wooferone central 20 mm dome tweeter
Material Body: extruded aluminium Grille: aluminium
Colour White RAL 9003
Connector Ceramic terminal
IP protection grade IP 66
Dimensions H 620 mm (24.4’’), L 114 mm (4.5’’), D 96 mm (3.8’’)
Net weight 4.5 kg (9.9 lb)
TECHNICAL SPECIFICATIONS
49
p/n 13133079
MODELLO SCALA
CS 6520EN 1:3
114 mm96 mm119 mm
55 mm
620
mm
50
CS 6940ENTWO-WAY COLUMN SPEAKERTwo-way speakers with very compact dimensions, the CS 6940 EN features 8 round extended-range speakers and a tweeter. This model utilizes a series of innovative technological solutions that guarantee highly intelligible reproduction of the vocal message. It’s complete with line transformer for directly connecting the speaker columns to 70V or 100V constant-voltage systems and permit selecting the power to be diffused from among various values. Thanks to IP 66 insulation, the speaker columns can also be used out of doors. Usable in railway stations, subways, churches, factories, warehouses, PA systems in general. EN 54-24:2008 certified.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0490/W)• Ideal for speech reproduction with high intelligibility in
acoustically difficult environments, both indoors and outdoors, also suitable for music.
• Rated power: 40W.• Eight 3,5” mid-woofer speakers and one central tweeter• Weather-resistant construction IP 66• Body in aluminum and front grille in steel bake-painted RAL
9003 White• Articulated support for wall mounting included.
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 40 W – 20 W – 10 W – 5 W
Input impedance (1 kHz) 250 Ω (40 W) - 500 Ω (20 W) - 1 kΩ (10 W) - 2 kΩ (5 W)
Frequency response 140 Hz ÷ 20 kHz (–10 dB)
Sensitivity 93 dB (1 W, 1 m)
Sound pressure level 109 dB (20 W, 1 m)
Transducer 8 x 3” mid-woofer and one central 20 mm dome tweeter
MaterialBody: extruded aluminium
Grille: aluminium
Colour White RAL 9003
Connector Ceramic terminal
IP protection grade IP 66
Dimensions H 956 mm (37.6’’) L 114 mm (4.5’’), D 96 mm (3.8’’)
Net weight 7.3 kg (16.06 lb)
p/n 13100005
MODELLO SCALA
CS 6940EN 1:3
114 mm96 mm
119 mm55 mm99
5 m
m
DU 50ENWALL/CEILING STEEL SPEAKERDU 50EN is a speaker with high intellegibility designed for use in alarm messages and background music.The 4.5” full range speaker is included in a steel can; the speaker is provided with a multitap transformer for 100V/70V constant voltage systems, a terminal block made with ceramic material for input and output antiflame cables and thermal switch. DU 50EN is EN 54-24 certified.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0489/W)• Speaker designed for transmitting alarm messages with high
intelligibility, and background music• Musical power/RMS: 12/6W• Wide-band dual cone loudspeaker, diameter 4.5”• Extra-thick steel housing, terminal strip for connections made
of ceramic material for fl ameproof input and output cables, thermal fuse, suitable internal wiring
• Colour: RAL 9010 White
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 6 W – 3 W – 1.5 W – 0.75 W
Input impedance 1.67 kΩ (6 W) – 3.33 kΩ (3 W) - 6.67 kΩ (1.5 W) – 13.33 kΩ (0.75 W)
Frequency response 190 Hz ÷ 11 kHz (–10 dB)
Sensitivity 90 dB (1 W, 1 m)
Sound pressure level 88 dB (6 W, 4 m)
Transducer 4.5’’ full range
Material Steel
Colour White RAL 9010
Connector Ceramic terminal
IP protection grade IP 40
Dimensions H 164 mm (6.5’’), L 164 mm (6.5’’), D 60 mm (2.4’’)
Net weight 2 kg (4.4 lb)
51
p/n 13133064
MODELLO SCALA
DU 50EN 1:2
163.5 mm60 mm
163.
5 m
m
21 m
m
DU 60ENWALL/CEILING STEEL SPEAKER
DU 60EN is a speaker with high intelligibility designed for use in alarm messages and background music. The 5” dual cone speaker is included in a steel can; the speaker is provided with a multitap transformer for 100V/70V constant voltage systems, a terminal block made with ceramic material for input and output flameproof cables and thermal switch. DU 60EN is EN 54-24 certified.
Main Features
• EN 54-24:2008 certified (CPR: 1488-CPR-0488/W)• Steel construction.• Dual cone 5” loudspeaker.• Transformer for connection to 100 V (/ 70 V) constant voltage
lines.• Power selection among four values.• Ceramic terminal strips.• Thermal fuse that prevents damage to the audio line due to
heat on the speaker.• Colour: RAL 9016 White
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 6 W – 3 W – 1.5 W – 0.75 W
Input impedance 1.67 kΩ (6 W) – 3.33 kΩ (3 W) - 6.67 kΩ (1.5 W) – 13.33 kΩ (0.75 W)
Frequency response 100 Hz ÷ 20 kHz (–10 dB)
Sensitivity 92 dB (1 W, 1 m), 80 dB (1 W, 4 m)
Sound pressure level 100 dB (6 W, 1 m), 88 dB (6 W, 4 m
Transducer 5” dual-cone
Material Steel
Colour White RAL 9016
Connector Ceramic terminal
IP protection grade IP 40
Dimensions ø 195 mm (7.7”), H: 75 mm (2.9”)
Net weight 1.9 kg (4.2 lb.)
52
p/n 13133083
MODELLO SCALA
DU 60EN 1:2
195 mm165 mm155 mm
75 mm40 mm35 mm
3.5 mm
20 m
m
HD 21ENPLASTIC HORN SPEAKER
HD 21EN is a 30W, EN 54-24 certified horn loudspeaker. Thanks to the IP 66 protection and its UV resistant ABS housing and it is suitable for both indoors and outdoors applications.It can be easily aimed towards any direction through the adjustable wall-mount bracket, and can used in sounds systems having large spaces, for instance supermarkets, railway stations, undergrounds, factories, warehouses, etc. and also in all environments that need high efficiency loudspeakers grade. Equipped with transformer for 100 V / 70 V constant voltage lines, internal power setting and ceramic terminal strip to link cables, it also has a thermal fuse that prevents damages to the audio line due to heat.
Main Features
• Compact speaker with 30 W driver• Rear cover in UV stabilized self-extinguishing ABS• Suitable for indoor and outdoor use (thanks to IP 66 pro-
tection)• Transformer for 100 V (/ 70 V) constant voltage connection• Thermal fuse to protect the audio line from heat
p/n 13133075
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 30 W – 15 W – 7.5 W – 3.75 W (100 V)15 W – 7.5 W – 3.75 W – 1.875 W (70 V)
Input impedance 333 Ω (30W) - 667 Ω (15W) - 1.33 kΩ (7.5 W) - 2.67 kΩ (3.75 W)
Frequency response 340 Hz ÷ 9 kHz (–10 dB)
Sensitivity 104 dB (1 W, 1 m), 92 dB (1 W, 4m)
Sound pressure level 119 dB (30 W, 1 m), 107 dB (30 W, 4 m)
Transducer 38 mm dome compression driver
Material ABS
Colour Light grey
Connector Ceramic terminal
IP protection grade IP 66
Dimensions ø 212 mm (8.3”), depth: 279 mm (10.9”)
Net weight 2 kg (4.4 lb.)
53
MODELLO SCALA
HD 21EN 1:2
212 mm
280 mm
151
mm
106 mm
60 mm
7 mm
54
HD 31ENPLASTIC HORN SPEAKER
p/n 13100004
HD 31EN is a 30W horn. Thanks to IP66 protection and its UV resistant ABS housing and it is suitable for both indoors and outdoors applications. It can be easily aimed towards any direction through the adjustable wall-mount bracket, and can used in sounds systems having large spaces, for instance supermarkets, railway stations, undergrounds, factories, warehouses, etc. and also in all environments that need high efficiency loudspeakers grade. Equipped with transformer for 100V/70V constant voltage lines, internal power setting and ceramic terminal strip to link cables, it also has a thermal fuse protection. EN 54-24:2008 certified.
Main Features
• Compact horn speaker with 30 W driver• Rear cover in UV stabilized self-extinguishing ABS• Suitable for indoor and outdoor use (thanks to IP 66 pro-
tection)• Transformer for 100V/70 V constant voltage connection• Thermal fuse to protect the audio line from heat• Color: Grey RAL 7035
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 30 W – 15 W – 7.5 W – 3.75 W
Input impedance (1 kHz) 333 Ω (30 W) - 667 Ω (15 W) - 1.33 kΩ (7.5 W) - 2.67 kΩ (3.75 W)
Frequency response 400 Hz ~ 7.5k Hz
Sensitivity 110 dB (1 W, 1 m)
Sound pressure level 125 dB (30 W, 1 m)
Transducer 38 mm dome compression driver
Material ABS
Colour Light grey
Connector Ceramic terminal
IP protection grade IP 66
Dimensions 232.7 (9.16) Dia. X 309.6 (12.19) Length mm. (in.)
Net weight 2.11 kg (4.65 lb)
MODELLO SCALA
HD 31EN 1:2
212 mm
325 mm
151
mm
106 mm
60 mm
7 mm
HD 6045ENLONG-THROW MULTI CELL HORN SPEAKER
HD 6045EN is a fiberglass horn designed to withstand the most adverse weather conditions, offering high sound reproduction quality and sound pressure levels. A high level of efficiency and sound pressure can be obtained thanks to the use of 4 dynamic driver units for a total output power of 200W. Internal transformers for 100V/70V constant voltage systems are equipped with ceramic terminal blocks for input and output flameproof cables and thermal switch. HD 6045EN is EN 54-24 certified.
Main Features
• EN 54-24:2008 certified (CPR: 0068-CPR-030/2015)• Long-throw horn speaker• Body in RAL 9003 white fiberglass• Mounting bracket• Watertight construction• IP 65 protection grade• 4 x 50W drivers with transformers for constant voltage line
TECHNICAL SPECIFICATIONS
Input voltage 100 V – (70 V)
Power 200 W
Input impedance 50 Ω (100 V, 200 W)
Frequency response 200 Hz ÷ 10 kHz (–10 dB)
Sensitivity 110 dB (200 W, 1 m), 91 dB (200 W, 4 m)
Sound pressure level 133 dB (200 W, 1 m), 114 dB (200 W, 4 m)
Transducer 4 x 50 mm (2’’) horn loaded compression driver units
Material Fiberglass
Colour White RAL 9003
Connector Ceramic terminal
IP protection grade IP 65
Dimensions H 620 mm (24.4’’), L 475 mm (18.7’’), D 564 mm (22.2’’)
Net weight 21.4 kg (47 lb.)
55
p/n 13133085
MODELLO SCALA
HD 6045EN 1:5
620 mm
564 mm
475
mm
The CV Series cables are suitable for the transmission of electrical signals and commands for those applications where maximum security is required in situations of fire alarm. They ensure the transmission of the signal to emergency speakers even when exposed to flames, allowing the safe evacuation of the environments where they are installed. The CV Series cable are suitable for fixed installation indoors in wet or normal environments, and temporarily outside. They can be installed on platforms, pipes, conduits and similar systems.
FIRE RESISTANT LOUDSPEAKER CABLES
56
CV 210SPEAKER CABLE 100V SECTION 2 X 1 MMQ
p/n 14380030 p/n 14380031 p/n 14380032
57
CV 215SPEAKER CABLE 100V SECTION 2 X 1.5 MMQ
CV 225SPEAKER CABLE 100V SECTION 2 X 2.5 MMQ
MODEL CR 2609 CR 2615 CR 2615 FV CR 2628 CR 2642
Part number 171.70.179 171.70.080 171.70.129 171.70.081 171.70.082
Type 9 U 15 U 15 U 28 U 42 U
Base dimensions 600 x 500 mm 600 x 600 mm 600 x 600 mm 600 x 600 mm 600 x 600 mm
Height 470 mm 800 mm 800 mm 1600 mm 2000 mm
Weight 24 Kg 26 Kg 30 Kg 54 Kg 68 Kg
Max load 25 Kg mountable on rack 105 Kg 100 Kg 320 Kg 350 Kg
Ventilation Natural ventilation on sides - Thermostat controlled Thermostat controlled Thermostat controlled
Thermal dissipation 25 °c 100 W 230 W 3130 W 3280 W 3320 W
Thermal dissipation 35 °c 150 W 140 W 2070 W 2160 W 2180 W
Included accessories - 4 wheels with braking system
4 wheels with braking system
- -
Model door (included) AK 2615 AK 2615 AK 2628 AK 2642
Part number door - (173.60.028) (173.60.028) (173.60.029) (173.60.030)
FOR THE OPTIMUM MANAGEMENT OF THE SYSTEM CONFIGURATIONS
RACKCOMPONENTS
58
CR 2600 RACK ENCLOSURES • The CR 2600 series rack enclouseres are designed to hold all
RCF 19" rack standard components.• They are constructed in compliance with the IEC 297-2
dimensional standard, and the depth is 600 mm for all models.
• The structure is made of steel painted RAL 7035 light grey. The rack enclosures are bake-painted at high temperature using epoxy powders to make the structure unalterable over time and resistant to scratching, abrasion, and atmospheric agents.
• The protection level is IP 30. The CR 2600 SERIES rack enclosures are composed of a basic structure that is assembled simply and quickly by fitting and securing four steel uprights to the upper and lower panels.
• The lower door and side panels are fitted following the wiring operations to facilitate the insertion and connection of the components. The lower panel, which forms the base of the rack, has openings for the passage of external connection cables (speaker lines, power supply, data, etc.) that are sized and shaped to guarantee the electrical safety of the structure. The earthing of the rack complies with current safety regulations.
• For the optimisation of the internal wiring, supports are supplied to gather the cable and attach them in an orderly fashion. The packing materials can be reused for transport the enclosure once it has been wired.
• Front doors are also available, which are useful for to protect the components installed in the rack.
• 5-socket frame, Schuko and Italian standard, on back-rack support 2U.
• Portion of Omega bar for installing 5 Omega standard modules
• 16A total capacity; cable included
AR 2605 FRAME WITHPOWER SOCKETSp/n 17360027
• Accessory for installation in RCF CR2600 series racks
AR 1050-NRACK LATERAL SUPPORT
p/n 17360039
• Wheels for RCF rack cabinets CR 2628 and CR 2642.
• The kit includes 2 wheels with brake and 2 swivel wheels. Wheel diameter: 80 mm .
• The maximum applicable load does not change when wheels are mounted.
• Front ventilation panel, 1U for CR 2600 series racks, RAL 9005 black
p/n 17130149
P AER1 FRONT VENTILATION PANELSp/n 17360038
RR 2601RACK WHEELS KIT
59
BH 1042BATTERY HOLDER
• Universal battery holder for RCF series “CR2600”
p/n 17360040
p/n17170137
483
44 271VENTILATION UNIT
483
44 160POWER
483
88 383
483
44 244POWERMESSAGE SIREN MONITOR0 10
VOLUME
SIGN PEAK
SPEAKERALARMMIC 1
1 2 3 4
MESSAGES PLAY REC PAUSE SIRENSTOP MONITOR0 10 0 10
483
44 244POWER
mm
5˙000 g
• The ventilation unit is composed of 3 fans (powered by 230 V AC) with one main switch on the rear panel
• It can be turned on from the thermostat of rack units belonging to the CR 2600 Series
• The ventilation unit has an air flow capacity of 500 m/h, from the bottom to the top
• 19” Rack mounting
• Energy consumption less than 45 W
• Low noise
PV 2603 is a ventilation unit composed by 3 blowers (230 V ac) and a main switch.The blowers turn on due to the activation command of a thermostat included in all RCF CR 2600 rack cabinets series.
PV 2603VENTILATION UNIT
60
• 1U Closure Panel• RAL 9005 Nero
• 2U Closure Panel• RAL 9005 Nero
• 3U Closure Panel• RAL 9005 Nero
• 4U Closure Panel• RAL 9005 Nero
CLOSURE PANELS PU 1 p/n 17170145
PU 2 p/n 17170146
PU 3 p/n 17170147
PU 4 p/n 17170148
61
Notes
10116190
RCF S.p.A. Italytel. +39 0522 274 411e-mail: info@rcf.it
RCF UKtel. 0844 745 1234int. +44 (0) 1702 800846e-mail: info@rcfaudio.co.uk
RCF Francetel. +33 1 49 01 02 31e-mail: france@rcf.it
RCF Germanytel. +49 2203 925370e-mail: germany@rcf.it
RCF USA Inc. tel. +1 732-9026100e-mail: info@rcf-usa.com
RCF Spaintel. +34 91 817 42 66e-mail: info@rcfaudio.es
HEADQUARTERS:
RCF Benelux tel. +49 (0) 2203 9253724e-mail: benelux@rcf.it
www.rcf.it
01/2017
top related