FXAQ-PVJU EDUS391100A-F6
Table of Contents
1. Specifications .............................................................................................22. Dimensions .................................................................................................53. PipingDiagrams .........................................................................................84. WiringDiagrams .........................................................................................95. ElectricCharacteristics ............................................................................. 116. SafetyDevicesSetting .............................................................................127. CapacityTables ........................................................................................13
7.1 CoolingCapacityatTe:43°F(6°C) .................................................137.2 HeatingCapacity .............................................................................137.3 CorrectionFactorforCoolingCapacityatTe:48°F(9°C) ...............13
8. AirVelocityandTemperatureDistributions(ReferenceData) ..................148.1 CoolingMode ..................................................................................148.2 HeatingMode ..................................................................................19
9. SoundLevels(ReferenceData) ...............................................................24
2
FXAQ-PVJU EDUS391100A-F6
1. Specifications
Wall mounted type
Model FXAQ07PVJU FXAQ09PVJUPowersupply 1phase,208/230V,60Hz 1phase,208/230V,60Hz1,3Coolingcapacity Btu/h 7,500 9,5002,3Heatingcapacity Btu/h 8,500 10,500Casing/Color White(3.0Y8.5/0.5) White(3.0Y8.5/0.5)Dimensions:(H×W×D) in. 11-3/8×31-1/4×9-1/4 11-3/8×31-1/4×9-1/4Coil(crossfincoil)
Rows×Stages×FPI 2×14×17 2×14×17Facearea ft² 1.73 1.73
Fan
Model QCL9661M QCL9661MType Crossflowfan CrossflowfanMotoroutput W 40 40Airflowrate(H/L) cfm 260/160 280/175Drive Directdrive Directdrive
Temperaturecontrol Microprocessorthermostatforcoolingandheating Microprocessorthermostatforcoolingandheating
Soundabsorbingthermalinsulationmaterial Foamedpolystyrene/Foamedpolyethylene Foamedpolystyrene/Foamedpolyethylene
Airfilter Resinnet(washable) Resinnet(washable)4Soundpressurelevel(referencedata)(H/L) dBA 36/31 37/31
Weight lbs 26 26
Pipingconnections
Liquidpipes in. f1/4(flareconnection) f1/4(flareconnection)Gaspipes in. f1/2(flareconnection) f1/2(flareconnection)
Drainpipe in. VP13(externaldia.11/16,internaldia.1/2)
VP13(externaldia.11/16,internaldia.1/2)
Safetydevices Fuse FuseRefrigerantcontrol Electronicexpansionvalve ElectronicexpansionvalveConnectableoutdoorunit R410AVRVseries R410AVRVseries
StandardaccessoriesOperationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation
tape,Insulationtube,Clamps,Screws
Operationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation
tape,Insulationtube,Clamps,Screws
Note:1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:
Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)
2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)
3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.4. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,
thesevaluesmaybehigherasaresultofinstallationconditions.
C:3D075572A
3
FXAQ-PVJU EDUS391100A-F6
Wall mounted type
Model FXAQ12PVJU FXAQ18PVJUPowersupply 1phase,208/230V,60Hz 1phase,208/230V,60Hz1,3Coolingcapacity Btu/h 12,000 18,0002,3Heatingcapacity Btu/h 13,500 20,000Casing/Color White(3.0Y8.5/0.5) White(3.0Y8.5/0.5)Dimensions:(H×W×D) in. 11-3/8×31-1/4×9-1/4 11-3/8×41-3/8×9-1/4
Coil(crossfincoil)
Rows×Stages×FPI 2×14×17 2×14×17Facearea ft² 1.73 2.29
Fan
Model QCL9661M QCL9686MType Crossflowfan CrossflowfanMotoroutput W 40 43Airflowrate(H/L) cfm 290/180 500/400Drive Directdrive Directdrive
Temperaturecontrol Microprocessorthermostatforcoolingandheating MicroprocessorthermostatforcoolingandheatingSoundabsorbingthermalinsulationmaterial Foamedpolystyrene/Foamedpolyethylene Foamedpolystyrene/Foamedpolyethylene
Airfilter Resinnet(washable) Resinnet(washable)4Soundpressurelevel(referencedata)(H/L) dBA 38/31 43/37
Weight lbs 26 31
Pipingconnections
Liquidpipes in. f1/4(flareconnection) f1/4(flareconnection)Gaspipes in. f1/2(flareconnection) f1/2(flareconnection)
Drainpipe in. VP13(externaldia.11/16,internaldia.1/2)
VP13(externaldia.11/16,internaldia.1/2)
Safetydevices Fuse FuseRefrigerantcontrol Electronicexpansionvalve ElectronicexpansionvalveConnectableoutdoorunit R410AVRVseries R410AVRVseries
StandardaccessoriesOperationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation
tape,Insulationtube,Clamps,Screws
Operationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation
tape,Insulationtube,Clamps,Screws
Note:1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:
Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)
2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)
3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.4. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,
thesevaluesmaybehigherasaresultofinstallationconditions.
C:3D075572A
4
FXAQ-PVJU EDUS391100A-F6
Wall mounted type
Model FXAQ24PVJUPowersupply 1phase,208/230V,60Hz1,3Coolingcapacity Btu/h 24,0002,3Heatingcapacity Btu/h 26,500Casing/Color White(3.0Y8.5/0.5)Dimensions:(H×W×D) in. 11-3/8×41-3/8×9-1/4
Coil(crossfincoil)
Rows×Stages×FPI 2×14×17Facearea ft² 2.29
Fan
Model QCL9686MType CrossflowfanMotoroutput W 43Airflowrate(H/L) cfm 635/470Drive Directdrive
Temperaturecontrol MicroprocessorthermostatforcoolingandheatingSoundabsorbingthermalinsulationmaterial Foamedpolystyrene/Foamedpolyethylene
Airfilter Resinnet(washable)4Soundpressurelevel(referencedata)(H/L) dBA 47/41
Weight lbs 31
Pipingconnections
Liquidpipes in. f3/8(flareconnection)Gaspipes in. f5/8(flareconnection)
Drainpipe in. VP13(externaldia.11/16,internaldia.1/2)
Safetydevices FuseRefrigerantcontrol ElectronicexpansionvalveConnectableoutdoorunit R410AVRVseries
Standardaccessories Operationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulationtape,Insulationtube,Clamps,Screws
Note:1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:
Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)
2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)
3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.4. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,
thesevaluesmaybehigherasaresultofinstallationconditions.
C:3D075572A
8
FXAQ-PVJU EDUS391100A-F6
3. Piping Diagrams
FXAQ07-24PVJU
Unit:in.(mm)Model Gas Liquid
FXAQ07PVJUFXAQ09PVJUFXAQ12PVJUFXAQ18PVJU
f 1/2(f 12.7)
f 1/4(f 6.4)
FXAQ24PVJU f 5/8(f 15.9)
f 3/8(f 9.5)
C: 4D034245R
9
FXAQ-PVJU EDUS391100A-F6
4. Wiring Diagrams
FXAQ07-24PVJU
C: 3
D07
5354
F
(NO
TES)
1.
: TE
RM
INAL
,
:
FIE
LD W
IRIN
G,
: C
ON
NEC
TOR
,
: C
ON
NEC
TOR
,
: P
RO
TEC
TIVE
GR
OU
ND
(SC
REW
),
: N
OIS
ELES
S G
RO
UN
D,
:
SHO
RT
CIR
CU
IT C
ON
NEC
TOR
2. IN
CAS
E U
SIN
G C
ENTR
AL R
EMO
TE C
ON
TRO
LLER
, CO
NN
ECT
IT T
O T
HE
UN
IT IN
AC
CO
RD
ANC
E W
ITH
TH
E AT
TAC
HED
INST
ALLA
TIO
N M
ANU
AL.
3. S
YMBO
LS S
HO
W A
S FO
LLO
WS:
RED
: RED
WH
T: W
HIT
E G
RN
: GR
EEN
PN
K: P
INK
YLW
: YEL
LOW
BLK
: BLA
CK
OR
G: O
RAN
GE
BR
N: B
RO
WN
BLU
: BLU
E4.
WH
EN C
ON
NEC
TIN
G T
HE
INPU
T W
IRES
FR
OM
OU
TSID
E, F
OR
CED
OFF
OR
ON
/OFF
CO
NTR
OL
OPE
RAT
ION
CAN
BE
SELE
CTE
D B
Y R
EMO
TE C
ON
TRO
LLER
. IN
DET
AILS
, REF
ER T
O T
HE
INST
ALLA
TIO
N M
ANU
AL A
TTAC
HED
TO
TH
E U
NIT
.5.
REM
OTE
CO
NTR
OLL
ER M
OD
EL V
ARIE
S AC
CO
RD
ING
TO
TH
E C
OM
BIN
ATIO
N S
YSTE
M, C
ON
FIR
M E
NG
INEE
RIN
G D
ATA
AND
CAT
ALO
GS,
ETC
. BEF
OR
E C
ON
NEC
TIN
G.
6. C
ON
FIR
M T
HE
MET
HO
D O
F SE
TTIN
G T
HE
SELE
CTO
R S
WIT
CH
(SS1
, SS2
) OF
WIR
ELES
S R
EMO
TE C
ON
TRO
LLER
BY
INST
ALLA
TIO
N M
ANU
AL A
ND
EN
GIN
EER
ING
DAT
A, E
TC.
7. X
15A,
X24
A, X
35A
AND
X38
A AR
E C
ON
NEC
TED
WH
EN T
HE
OPT
ION
AL A
CC
ESSO
RIE
S AR
E BE
ING
USE
D.
8. C
LASS
2 W
IRE
10
FXAQ-PVJU EDUS391100A-F6
FXAQ07-24PVJU
INDOORUNITA1P PRINTEDCIRCUITBOARDC5 CAPACITORF1U FUSE(T,3.15AH,250V)F2U FUSEHAP FLASHINGLAMP(SERVICEMONITORGREEN)M1F MOTOR(INDOORFAN)M1S MOTOR(SWINGFLAP)R1T THERMISTOR(AIR)R2T THERMISTOR(COILLIQUIDPIPE)R3T THERMISTOR(COILGASPIPE)V1R DIODEBRIDGEX1M TERMINALBLOCK(CONTROL)X2M TERMINALBLOCK(POWER)Y1E ELECTRONICEXPANSIONVALVEZ1C FERRITECOREZ1F NOISEFILTERPS SWITCHINGPOWERSUPPLYRECEIVER/DISPLAYUNIT(ATTACHEDTOWIRELESSREMOTECONTROLLER)A2P PRINTEDCIRCUITBOARDA3P PRINTEDCIRCUITBOARDBS1 PUSHBUTTONSWITCH(ON/OFF)H1P PILOTLAMP(ON-RED)H2P PILOTLAMP(TIMER-GREEN)H3P PILOTLAMP(FILTERSIGN-RED)H4P PILOTLAMP(DEFROST-ORANGE)SS1 SELECTORSWITCH(MAIN/SUB)SS2 SELECTORSWITCH(WIRELESSADDRESSSET)CONNECTORFOROPTIONALPARTSX15A CONNECTOR(FLOATSWITCH)X24A CONNECTOR(WIRELESSREMOTECONTROLLER)X35A CONNECTOR(GROUPCONTROLADAPTOR)X38A CONNECTOR(ADAPTORFORMULTITENANT)
C:3D075354F
11
FXAQ-PVJU EDUS391100A-F6
5. Electric Characteristics
FXAQ07-24PVJU
ModelPowersupply IFM Input(W)
Hz Volts Voltagerange MCA MOP kW FLA Cooling HeatingFXAQ07PVJU
60 208/230V Max.253VMin.187V
0.4 15 0.040 0.3 19 29FXAQ09PVJU 0.4 15 0.040 0.3 28 34FXAQ12PVJU 0.4 15 0.040 0.3 30 35FXAQ18PVJU 0.5 15 0.043 0.4 33 39FXAQ24PVJU 0.6 15 0.043 0.5 50 60
Symbol:MCA:MinimumCircuitAmpacity(A)MOP:MaximumOvercurrentProtectiveDevice(A)kW: FanMotorRatedOutput(kW)FLA: FullLoadAmpacity(A)IFM: IndoorFanMotor
Note:1.Voltagerange Unitsaresuitableforuseonelectricalsystemswherevoltagesuppliedtounitterminalsisnotbeloworabovelistedrangelimits.
2.Maximumallowablevoltageunbalancebetweenphasesis2%.3.MCA/MOP MCA=1.25×FLA MOP≤4×FLA (Nextlowerstandardfuseraring.Minimum15A)
4.SelectwiresizebasedonthevalueofMCA.5.Eitherafuseoracircuitbreakerisacceptable.
C:4D075550
12
FXAQ-PVJU EDUS391100A-F6
6. Safety Devices Setting
Model FXAQ07PVJU FXAQ09PVJU FXAQ12PVJU FXAQ18PVJU FXAQ24PVJUPCboardfuse 250V,3.15A 250V,3.15A 250V,3.15A 250V,3.15A 250V,3.15AFanmotorthermalfuse °F — — — — —Fanmotorthermalprotector °F — — — — —
C:4D047085D
13
FXAQ-PVJU EDUS391100A-F6
7. Capacity Tables7.1 Cooling Capacity at Te: 43°F (6°C)
Model
Indoorairtemp.°FWB(°CWB)(Te:43°F(6°C))61(16.1) 64(17.8) 67(19.4) 70(21.1) 72(22.2) 75(23.9)
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHCMBH MBH MBH MBH MBH MBH MBH MBH MBH MBH MBH MBH
FXAQ07PVJU 5.9 5.6 6.7 6.1 7.5 6.4 8.0 6.5 8.1 6.3 8.2 6.0FXAQ09PVJU 7.5 6.5 8.5 7.2 9.5 7.3 10.1 7.4 10.2 7.4 10.4 7.0FXAQ12PVJU 9.5 7.9 10.7 8.3 12.0 8.9 12.7 8.9 12.9 8.8 13.1 8.5FXAQ18PVJU 14.2 11.7 16.1 12.7 18.0 13.7 19.1 13.6 19.3 13.3 19.7 12.4FXAQ24PVJU 18.9 15.3 21.5 16.5 24.0 18.0 25.5 17.8 25.8 17.6 26.3 16.2
TC: Totalcapacity:MBHSHC:Sensibleheatcapacity:MBH
Note:1.ThesecapacitytablescanbeusedwhenselectingaVRVindoorunit.TheactualcapacityoftheVRVsystemdependsonfactorssuchastheselectedmodelofoutdoorunits,outdoorairtemperatureandpipinglength.PleaseconfirmthatthecorrectedcapacityoftheVRVsystemsatisfiestherequiredheatload.
2. showsratedcondition.
7.2 Heating Capacity
Model
Indoorairtemp.°FDB(°CDB)(Tc:115°F(46°C))62(16.7) 65(18.3) 68(20.0) 70(21.1) 72(22.2) 75(23.9)
TC TC TC TC TC TCMBH MBH MBH MBH MBH MBH
FXAQ07PVJU 9.3 9.2 8.7 8.5 8.1 7.7FXAQ09PVJU 11.8 11.7 11.1 10.5 10.3 9.7FXAQ12PVJU 14.9 14.7 14.0 13.5 13.0 12.3FXAQ18PVJU 22.3 22.1 21.0 20.0 19.5 18.4FXAQ24PVJU 29.2 29.0 27.5 26.5 25.5 24.0
TC:Totalcapacity:MBH
Note:1.ThesecapacitytablescanbeusedwhenselectingaVRVindoorunit.TheactualcapacityoftheVRVsystemdependsonfactorssuchastheselectedmodelofoutdoorunits,outdoorairtemperatureandpipinglength.PleaseconfirmthatthecorrectedcapacityoftheVRVsystemsatisfiestherequiredheatload.
2. showsratedcondition.
7.3 Correction Factor for Cooling Capacity at Te: 48°F (9°C)
Refertothecorrectionfactortablebelowwhenamini-splitindoorunit isconnectedtoaVRVHeatPumpsystemusingaBranchPortbox.
ModelIndoorairtemp.°FWB(°CWB)(Te:48°F(9°C))
57(13.9) 61(16.1) 64(17.8) 67(19.4) 70(21.1) 72(22.2) 75(23.9)TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF
FXAQ07PVJU 0.69 1.13 0.69 1.19 0.74 1.14 0.77 1.11 0.80 1.08 0.82 1.06 0.83 1.05FXAQ09PVJU 0.69 1.12 0.69 1.19 0.74 1.15 0.77 1.11 0.80 1.07 0.82 1.06 0.83 1.05FXAQ12PVJU 0.70 1.10 0.69 1.19 0.73 1.15 0.77 1.09 0.80 1.07 0.82 1.06 0.83 1.05FXAQ18PVJU 0.69 1.12 0.69 1.18 0.75 1.13 0.78 1.09 0.82 1.06 0.83 1.05 0.85 1.05FXAQ24PVJU 0.69 1.10 0.69 1.18 0.75 1.13 0.79 1.09 0.82 1.06 0.84 1.05 0.85 1.05
TC: TotalcapacitySHF:Sensibleheatfactor
CA14A307C
14
FXAQ-PVJU EDUS391100A-F6
8. Air Velocity and Temperature Distributions (Reference Data)8.1 Cooling ModeFXAQ07PVJU <Cooling mode>
C: 3D053942
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
15
FXAQ-PVJU EDUS391100A-F6
FXAQ09PVJU <Cooling mode>
C: 3D053943
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
16
FXAQ-PVJU EDUS391100A-F6
FXAQ12PVJU <Cooling mode>
C: 3D052935
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
17
FXAQ-PVJU EDUS391100A-F6
FXAQ18PVJU <Cooling mode>
C: 3D052936
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
18
FXAQ-PVJU EDUS391100A-F6
FXAQ24PVJU <Cooling mode>
C: 3D052937
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
19
FXAQ-PVJU EDUS391100A-F6
8.2 Heating ModeFXAQ07PVJU <Heating mode>
C: 3D053942
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
20
FXAQ-PVJU EDUS391100A-F6
FXAQ09PVJU <Heating mode>
C: 3D053943
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
21
FXAQ-PVJU EDUS391100A-F6
FXAQ12PVJU <Heating mode>
C: 3D052935
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
22
FXAQ-PVJU EDUS391100A-F6
FXAQ18PVJU <Heating mode>
C: 3D052936
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
23
FXAQ-PVJU EDUS391100A-F6
FXAQ24PVJU <Heating mode>
C: 3D052937
AIRFLOW DISTRIBUTIONS
TEMPERATURE DISTRIBUTIONS
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the user’s manual carefully before using this product. The user’s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any inquiries, please contact your local importer, distributor and/or retailer.
©All rights reserved 01/21 FS
●Specifications, designs and other content appearing in this brochure are current as of January 2021 but subject to change without notice.
top related