Digital manometer DruckTest 2000Gas leak detector VibraGAS and combination deviceLeckOmiO - Leak location with intelligent options
Pictures of aPPlication
Hand-held measurement device
• Ruggedhand-heldinstrumentswithergonomicaluminumhousing
• Widerangeofapplicationsinthegasinstallation
• Load-andtightnesstestsaccordingtoTRGI
• Powerfulgasdetectorwithvibrationalarmanddigitaldisplayreadingforgasleakdetection
• HighcontrastLCDdisplaywithbacklightforanoptimalpresentationofallmeasuredvalues
• EasyreplacementofbatterieswithinnovativebatteryManagement
• SystematicevaluationofthemeasureddatausingEsdersPC-1software
• Graphicalprintoutonsiteonmobileprinter
• Simpleoperationwithintuitivemenunavigation
• Practicalaccessoriesforallapplications
Gas Water Pressure Detection of cable faults
technical Data
Typical applications
Display LCDgraphicdisplaywith128x64pixels+specialcharacters,with backlight
Powersupply 4pcs1.5VAlkalineAABatteriesorNiMHbatterypackOperating time with alkaline manganese batteries
>100hoursatpressuremeasurement(withoutlighting)>20hoursatGasdetection(withoutlighting)
Measuringrange 0bis10.000ppmMethan;Auflösung1,10,50,100und1.000ppm0bis200mbar(hPa)und200bis2000mbar;Auflösung0,1mbarund1mbar
OperatingTemperature –20°Cto+50°CDimensions 149–165x58x34mmwithoutgooseneckmicrophone(gooseneck162mm)
Weight ca.400gwithbatteries
LoadandtightnesstestingaccordingtoTRGI,regulatorexamination,measurementofflow,restingandworkingpressures,pressuretestsongaspipesandgaspipesfreeexaminationof theirex-ternalleaks.Theinstrumentsareavailableassingleorcombinationdeviceandthereforeversatileinthegasinstallation.ThroughtheintuitiveEsdersoperatingphilosophyasimpleandeconomicaloperationisgiven.
Function VibraGAS DruckTest 2000 LeckOmiO
BuildingInspection
PressureTest
RegulatorTest
LoadtestaccordingtoTRGI
TightnesstestaccordingtoTRGI
Thefollowingmenuoptionsareavailable:
• Pressure Test displayofstartingpressure,finalpressure,measurementtimeandpressure drop,aswellasminimallyandmaximumpressurevalue.
• Regulator Testdisplayoftheoutgoingpressure,closingpressure,safetypressurerelease valveresponsepressureandleak-proofcompletion,upperandlowerdeactivationof safetyshut-offvalveandleak-proofcompletion.
• Load test according to TRGIMenu-drivenprocedurewithindividualAdjustingofthe measuringtimetotherequirementsoftheTRGIloadtesting
• Tightness test according to TRGIMenu-drivenprocedurewithindividualAdjustingofthe measuringtimetotherequirementsoftheTRGItightnesstesting
• Building inspection detectionofsmallestleaksinplumbinglinesandconnections. Inadditiontotheopticalandacousticsignalavibrationalarmisavailable.
• SettingsCustomconfigurationoftheoperatingparameterssuchasthemeasuringunit, automaticswitchofforthedutycycleofthebacklighttotheuser‘srequirements.
• AdjustmentSensorsensitivitytestandcalibrationofthedeviceaccordingtoDVGWNote G465-4byapplyingtestgasandsetpointadjustmentbypressingabutton
Gas Water Pressure Detection of cable faults