Vectus® Laser

A dedicated, powerful solution for high-

volume hair removal

• Providing fast, uniform and

permanent hair reduction for the

widest range of skin and hair types

– without sacrificing client comfort.

Absorption Coefficient

3

Hair shaft containing melanin

Epidermis containing melanin

Stem cells responsible for hair growth

cycle (do not contain pigment)

Hair matrix is the factory of hair follicle cells

and shaft. Hair matrix has the highest

melanin concentration

Hair Follicle Structure

Photoepilation

5

• Thermal destruction of hair

bulb stops hair growth

• Thermal injury of stem cells

causes permanent hair

reduction

Cold Window

Speed and Efficacy are the Keys to Success

Speed

• Largest spot sizes for the fastest treatments possible

Efficacious Treatments

• Skintel Provides Treatment Confidence

• Uniform Beams Reduce Hot Spots

• Advanced Contact Cooling Improves Patient Comfort

• Photon Recycling Maximizes Clinical Results

Largest Spot Sizes for the Fastest Treatments

Small Sapphire Optic

12 mm x 12 mm = 144 mm2

Large Sapphire Optic

23 mm x 38 mm = 874 mm2

Largest Spot Sizes for the Fastest Treatments

LightSheer® Duet™ ET9 mm x 9 mm = 81 mm2

Vectus™ Laser

12 mm x 12 mm = 144 mm2

Vectus™ Laser23 mm x 38 mm = 874 mm2

LightSheer® Duet™ HS22 mm x 35 mm = 770 mm2

GentleLase™

18 mm

Skintel® Melanin Reader™

The industry’s only melanin reader

• Adds an element of treatment confidence

Measures the skin’s diffuse reflectance at three

unique wavelengths of light

• Values are computed into a melanin index (MI) value

which corresponds to a specific test spot fluence

• Enables ancillary staff to conduct treatments

How Do You Use Skintel?

3 EASY STEPS

1 Provider takes three sample measurements

on the skin within or near area to be treated

2 The average measurement is sent wirelessly

to the Vectus system

3 The user proceeds to enter client

characteristics: hair color; hair diameter;

and hair density

A test spot fluence is then calculated in real-time.

Melanin Index and Fitzpatrick Skin Type

Uniform Beams Help Reduce Hot Spots

Vectus Small Optic Vectus Large Optic

Uniform Beams Help Reduce Hot Spots

Vectus

Large Optic

Small Optic

Other Systems

Hot Spots

14

LightSheer Duet ET LightSheer Duet HS

Photos courtesy of Sean Doherty, MD

Boston Plastic Surgery Associates, Concord, MA

Co-Medical Director, Palomar Medical Technologies, Inc., Burlington, MA

Advanced Contact Cooling

• Unique coolant flow pattern for pre,

during and post treatment cooling

• Large sapphire block provides

excellent heat transfer

Maximum comfort

and minimized risk.

Photon Recycling™

Maximizes treatment results

by reducing energy loss

Highly reflective mirrors inside the

lamp send reflected photons of energy

back into the targeted area.

This innovative design can increase

the fluence available to heat the target

by 1.5 to 2 times!

SmoothPulseSM Technology

Competitors “spike profile” vs.

Vectus® “top hat” SmoothPulse

Spikes are often associated with

excessive rise in epidermal

temperature resulting in discomfort

and possible negative side-effects

17

Unique User Friendly Interface

Simple “Quadrant” design guides the user through

selecting the four key parameters:

• Hair density

• Fitzpatrick skin type

or Skintel value

• Hair diameter

• Hair color

No Disposables

Disposable components are required with other hair removal

systems such as the LightSheer Duet and the GentleLASE®.

• LightSheer Duet HS Insert: Approximately $8/insert

– 2-6 inserts often necessary to treat a male back

• GentleLASE Cryogen: Approximately $50/canister

Presentation Title is set in the Footer 19

Histology

Optimization of hair removal devices

requires sufficient fluence to be

delivered and absorbed by the follicle

in appropriate pulse widths to cause

the needed temperature rise of the

follicle’s cells without causing

excessive skin temperatures.

20

Histology

Vectus laser histology shows complete

follicular coagulation = effective cell death

21

Immediately Post Treatment

Vigorous perifollicular edema shows application of energy

22

Photos courtesy of Josefina Royo de la Torre, MD

Growing Market

Hair removal is the #1 requested energy-

based aesthetic treatment, with 12.2 million

procedures worldwide. It is expected to

grow to 12.9 million procedures in 2016.1

Nearly all women over age 12 engage in

hair removal on a regular basis,1 but males

are a rapidly growing patient segment.2

23

12.2

million

12.9

million

current 2016 projected

1. Global Aesthetic Market: An Era of Consolidation and Reorganization,

Medical Insights, Inc. 2013:125

2. Mini-Report: Male Patients: An Important Market Segment, Medical

Insights, Inc. 2014:22

Clinical Results – Underarm

Clinical Results – Male Back

Clinical Results – Male Back

Clinical Results – Chin

Clinical Results – Chin

Clinical Results – Leg

top related