Unisorb® Capsule Anchor SystemCapsule Anchor with Stud Assembly
This system provides a superior method of heavy duty anchoring using a high strength adhesive to retain a threaded rod and other materials such as rebar in concrete or other masonry material. The system consists of an adhesive capsule containing the proper proportion of base resin, hardener and aggregate for the anchor, an appropriate length stud with washer and nut, and a drive unit to allow the stud to be inserted into a standard hammer drill.
To install the anchor, a clearance hole is prepared and a capsule is inserted. The stud is driven into the hole with a standard hammer drill using the drive unit.
The driving action breaks the adhesive capsule HVU and mixes the pre-measured components. At room temperature the anchor nuts may be torqued down within approximately 30 minutes.
Extensive testing and field trials have proven the Unisorb HVU Adhesive Capsule Anchor Systems are among the most dependable on the market. They are far superior to the expansion type anchoring system, and stronger than the concrete itself.
SPECIFICATIONSAnchor
Sizeinch
Capsule Number
Qty. per
pack
Drill Dia. inch
Hole Depth inch
Anchor No. & Length
inch
*Allowable Tensile Load
lbs. / kN.
*Allowable Shear Load
lbs. / kN.
3/8 HVU 3/8 x 3-1/2 10 7/16 3-1/2 S-38 x 5-1/8
2595 109011.5 4.8
1/2 HVU 1/2 x 4-1/4 10 9/16 4-1/4 S-12 x 6-1/2
4735 194021.1 8.6
5/8 HVU 5/8 x 5 10 11/16 5 S-58 x 7-5/85245 3025
23.3 13.5
3/4 HVU 3/4 x 6-5/8 5 7/8 6-5/8 S-34 x 9-1/2
8615 435538.3 19.4
7/8 HVU 7/8 x 6-5/8 5 1 6-5/8 S-78 x 10-1/4
9130 593040.6 26.4
1 HVU 1 x 8-1/4 5 1-1/8 8-1/4 S-100 x 12
13425 774559.7 34.5
1-1/4 HVU 1-1/4 x 12 4 1-3/8 12 S-114 x 15
23920 12100106.4 53.8
*Allowable Load Data
• Tensile loads are based on a 4:1 safety factor applied to the tested bond strength of the adhesive to 4,000 psi (279.9 kg/cm2) concrete.
• Shear loads are based on an F 1554 Gr. 36 anchor and are based on the methods described in the AISC Manual of Steel Construction (Ninth Edition).
• Greater allowable loads are possible by using different anchor materials and by altering the embedment depth. Please contact the factory for information on custom anchoring applications.
Capsule Anchor with Internally Threaded InsertThis system provides a superior method of heavy duty anchoring using a high strength adhesive to retain a threaded insert in concrete or other masonry material. The system consists of an HVU Adhesive Capsule containing the proper proportion of base resin, hardener and aggregate for the anchor and an appropriately sized threaded insert. The customer provides an appropriately sized socket head cap screw and washer, along with a short length of hex stock to be used as a driver when inserted into the chuck of a standard hammer drill. The cap screw can then be used to secure the machine.
To install the anchor, a clearance hole is prepared and a capsule inserted. The threaded insert is driven into the hole with a standard rotary hammer drill using the equipment shown in the illustration below. This action breaking and mixing with pre-measured components. At room temperature, the anchor bolts may be torqued down in approximately 30 minutes.
• Tensile value based on bond/concrete capacity. Minimum concrete compressive strength is 2,000 psi.
• Allowable shear values assume the use of a bolt conforming to ASTM F3125 Gr. A325 (formerly ASTM A325).
HEX STOCK
SOCKET HEAD CAP SCREW
THREADED INSERT
FLAT WASHERDRILL CHUCK
SPECIFICATIONSInsert Size
inchCapsule Number
Drill Dia. inch
Hole Depth inch
Thread Length
inch
*Allowable Tensile Load
lbs. / kN.
*Allowable Shear Load
lbs. / kN.
3/8 x 4-3/8 HVU-1/2 x 4-1/2 11/16 4-3/8 7/8
3180 225014.1 10.0
1/2 x 5 HVU-5/8 x 5 7/8 5 1-1/4
4570 400520.3 17.8
5/8 x 6-5/8 HVU-7/8 x 6-5/8 1-1/8 6-5/8 1-5/8
7460 626033.2 27.8
3/4 x 8-1/4 HVU-1 x 8-1/4 1-1/4 8-1/4 2
9165 901040.8 40.1
Metric dimensions are for reference only.
MINIMUM CURE TIMESCONCRETE TEMPERATURE CURE TIME68°F (20°C) & Over 20 minutes50°F to 68°F (10°C to 20°C) 30 minutes32°F to 50°F (0°C to 10°C) 1 hour23°F to 32°F (-5°C to 0°C) 5 hours14°F to 23°F (-10°C to -5°C) 10 hours
Cure time should be doubled for wet concrete.
Scan QR Code For Full Product Data
INSTALLATION TECHNOLOGIES
INSTALLATION OF CAPSULE ANCHOR SYSTEM
CAPSULE ANCHOR WITH STUD ASSEMBLY
PRODUCT DATABOX 1000, JACKSON, MI 49204-1000
888-4-UNISORB • 517-764-6060FAX 517-764-5607 • www.unisorb.com
BULLETIN NO.GB-0146-2
PAGE 1 OF 3
INSTALLATION TECHNOLOGIES
08/17/18 JDM
Overview
This system provides a superior method of heavy duty anchoring using a high strength adhesive to retain a threaded rod and other materials such as rebar in concrete or other masonry material. The system consists of an adhesive capsule containing the proper proportion of base resin, hardener and aggregate for the anchor, an appropriate length stud with washer and nut, and a drive unit to allow the stud to be inserted into a standard hammer drill. To install the anchor, a clearance hole is prepared and a capsule is inserted. The stud is driven into the hole with a standard hammer drill using the drive unit. The driving action breaks the adhesive capsule HVU and mixes the pre-measured components. At room temperature the anchor nuts may be torqued down within approximately 30 minutes. Extensive testing and field trials have proven the Unisorb HVU Adhesive Capsule Anchor Systems are among the most dependable on the market. They are far superior to the expansion type anchoring system, and stronger than the concrete itself.
Instructions
Drive Unit
HVU Chemical Anchor
Stud Assembly; (1) Stud, (1) Nut, (1) Washer
Prior to starting the anchor installation, perform a layout to ensure all necessary components are present and in adequate condition. Confirm that the stud, drive unit and capsule are of the a compatible diameter. The components on the left show what is needed for a single anchor location. Drive units may be utilized for multiple locations.
2. After thoroughly cleaning dust and debris from newly drilled hole, place HVU Chemical Anchor Packet into hole as shown. Note the directional arrow shape of the packet being placed arrow down.
PRODUCT DATABOX 1000, JACKSON, MI 49204-1000
888-4-UNISORB • 517-764-6060FAX 517-764-5607 • www.unisorb.com
BULLETIN NO.GB-0146-2
PAGE 2 OF 3
INSTALLATION TECHNOLOGIES
1. Drill hole to specifications listed within the table.
SPECIFICATIONSAnchor Sizeinch / mm
Capsule Number Qty. per pack
Drill Dia. inch / mm
Hole Depth inch / mm
Anchor No. & Length inch / mm
*Allowable Tensile Loadlbs. / kg.
*Allowable Shear Load lbs. / kg.
3/8” HVU 3/8 x 3-1/2 10
7/16 3-1/2 S-38 x 5-1/8 2115 10909.5 11 89 S-38 x 130 961 4951/2” HVU 1/2
x 4-1/4 109/16 4-1/4 S-12 x 6-1/2 3755 1940
12.7 14 108 S-12 x 165 1707 8825/8”
HVU 5/8 x 5 1011/16 5 S-58 x 194 5870 3025
15.9 17 127 S-58 x 194 2668 13753/4” HVU 3/4
x 6-5/8 57/8 6-5/8 S-34 x 9-1/2 8455 4355
19.1 22 168 S-34 x 241 3843 1980
7/8” HVU 7/8 x 6-5/8 5
1 6-5/8 S-78 x 10-1/4 11510 5930
22.2 25 168 S-78 x 260 5232 26951” HVU 1
x 8-1/4 51-1/8 8-1/4 S-100 x 12 15035 7745
25.4 29 210 S-100 x 305 6834 35201-1/4” HVU 1-1/4
x 12 41-3/8 12 S-114 x 15 23485 12100
31.8 35 305 S-114 x 381 10675 5500 *Allowable Load Data
08/17/18 JDM
PRODUCT DATABOX 1000, JACKSON, MI 49204-1000
888-4-UNISORB • 517-764-6060FAX 517-764-5607 • www.unisorb.com
BULLETIN NO.GB-0146-2
PAGE 3 OF 3
INSTALLATION TECHNOLOGIES
4. Disconnect drill from drive unit, and drive unit from stud and allow to cure at least 30 minutes.
5. Once in place stud should appear as the photo (right) shows. Remove nut and washer prior to passing through object being anchored. At room temperature the anchor nuts may be torqued down within approximately 30 minutes.
3. Using a hammer drill, thread drive unit and assemble as shown (below left). Once assembled, begin driving the stud into the hole until recommended hole depth as been reached.
08/17/18 JDM