ultrasonic flow meters expertise innovation service · 2015-09-19 · expertise innovation service....
Post on 03-Aug-2020
3 Views
Preview:
TRANSCRIPT
UltrasonicFlow MetersExpertise InnovationService
Since its foundation in 1974 Ultraflux has been designing, developing, manufacturing and mar-keting its own extensive range of products. Our complete range includes, portable and fixed flow meters for liquids and gases, open channel me-ters, clamp on heat meters, interface and pig detectors and gas level measurement systems (i.e. level measurement in gas storage caverns).Ultraflux’s focus on ultrasonic transit time flow measurement and ultrasonic instrumentation gives us the technical skill and experience to solve even the most demanding applications.
We supply our systems Worldwide: more than 50% of our products are exported. We have sub-sidiaries in Brazil and Thailand and a network of highly experienced partners.
Our fields of application
01. Flow measurement on old pipe (1868)02. Gas flow measurement with 5 chords 03. Flow measurement on irrigation channel
Get introduced to
Specialist in ultrasonicflow meters
Quality manufacturersince 1974
01
02
03
As the world’s pioneer in ultrasonic flowmeters, it was Ul-traflux who developed the first instruments to be used in specific measurement applications by the major French groups. Since 1974, Ultraflux has kept on growing, conti-nually consolidating our original expertise and skills.This is what makes us, and our services, unique. One third of our workforce is made up of Engineers or Doctors. We place utmost importance on innovation, and this is backed up by a strict metrological approach and the results from our expe-rimental facilities. We are active across a huge range of in-dustries, from water and the environment to oil, chemistry, nuclear and hydroelectric… By combining a technological focus – ultrasonic flowmeters – and our multi-sector and multi-application skills, we convert our talents into a real growth engine for the company.In an effort to support this growth, Ultraflux moved to a new site in 2012. It gives us more space to build up our produc-tion facilities and install an even more effective research la-boratory.Lastly, we are continuing to strengthen our application engi-neering department in order to provide even more services to our customers, whether in terms of managing complex projects in collaboration with integrators or design offices, or in terms of technical support around our measuring points before, during and after installation.A complete understanding of processes and a metrological approach are now more than ever vehicles for progress in both industry and research.
This is our vision, and our commitment.
Jean-Olivier Schneider
01 & 02. Ultraflux headquarters in Éragny sur Oise — France03. Jean-Olivier Schneider, Ultraflux chairman & managing director
01
02
03
A word from the chairman
RIO BRASIL
ULTRAFLUxSUBSIDIARIES
BAngkOkThAILAnD
ULTRAFLUxhEADqUARTERS
ÉRAgny SUR OISE(30 kM FAR
FROM pARIS)
Ultraflux ISO 9001 Quality certification Ultraflux ISO 14001 Environment certification
ISO certificatesQuality and environment
Quality and environmental responsibility are of para-mount importance to our company: we are certified to ISO 9001 since 1997 and ISO 14001 since 2009.
ATEX certifications
Ultraflux ATEX certification – for an approved production quality assurance system
Ultraflux production quality assurance notification (page 2)
Ultraflux production quality assurance notification (page 1)
Our products are certified to ATEX since 2003.
Leading innovation is of paramount importance to us. That is why one third of our workforce is made up of Engineers or Doctors. Our research laboratory is located in France (Éragny sur Oise), where we build tomorrow’s products.
R&D department
01. Fabrication of insertion probes 02. Use of a coiling machine to make custom cables 03 & 04. Calibration of a spool piece before installation 05. Assembly of a portable flow meter
Teams of experts in charge of all production and special projects matters.
Production and engineering departments
0201
03
04
05
01. Calibration bench (flow loop) 02. Computation of the impact of complex geometry on flow with CFD (Computational fluid dynamics) 03. Ultraflux 3D scanning ultrasonic immersion tank 04. Simulation of the ultrasonic wave propagation 05. Ultrasonic field measurement — All images by Ultraflux
05
03
04
02
01
A team of specialists dedicated to set-up and reparation of material. We also have a task force in charge of after-sales for Asia (located in Bangkok).
After-sales department
01. Opening of a converter 02. Battery control 03. Flow meter calibration test 04. Electronic board fixing 05. Assembly of the converter after reparation 06. Software implementation
Our products
Flow meters for various application
Clamp-on, insertion & wetted probes
01 02
03
04
05
06
Portable flow meters for full pipe applications
01. Uf 801 P converter linked to a computer 02. Minisonic P converter with 1586 probes03. Flow measurement in liquids with solids 04. Flow measurement on small diameter pipe 05. Flow measurement in difficult conditions
Product name minisonic P uf 801 P
nature of equiPment pORTABLE FLOW METER pORTABLE FLOW METER
media measured LIqUIDS LIqUIDS AnD gASES
conditions of use pIpE UnDER LOAD pIpE UnDER LOAD
PiPe diameter Up TO 3300mm Up TO 10000mm**
standard mountedinPuts/outPuts
› 2 cURREnT OUTpUTS, 4-20mA (gALvAnIcALLy ISOLATED - IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT)
› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)
—
oPtional inPuts/outPuts
— in oPtion, uP to 4 modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 0-10v vOLTAgE InpUTS • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT InpUTS (pULSE OR STATE) • module 6
ingress Protection Ip 67 Ip 68
accuracy* Up TO 0.5% Up TO 0.5%
troubleshooting helP — › OScILLOScOpE FUncTIOn (EchO DISpLAyED)
› gAIn
› qUALITy InDEx
maximum number of sPeed chords
2 chORDS 2 chORDS
models available STAnDARD / DUAL pIpE / DUAL chORD STAnDARD / DUAL pIpE / DUAL chORDcALORIMETER / DUAL cALORIMETER
0201
03
04
05
* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.
** AppLIcATIOn cOnDITIOnS FOR gAS MEASUREMEnT: pLEASE cOnTAcT US.
01. Flow measurement on small diameter pipe02. Flow measurement of oil product03. Flow measurement with clamp-on probes04. Flow measurement with insertion probes
01
02 03
04
Fixed flow meters for full pipe applications
Product name minisonic 600 minisonic 2000
nature of equiPment FIxED FLOW METER FIxED FLOW METER
media measured LIqUIDS LIqUIDS
conditions of use pIpE UnDER LOAD pIpE UnDER LOAD
PiPe diameter Up TO 630mm Up TO 3300mm
standard mountedinPuts/outPuts
› 2 cURREnT OUTpUTS, 4-20mA (gALvAnIcALLy ISOLATED - IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT)
› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)
› 2 cURREnT OUTpUTS, 4-20mA (gALvAnIcALLy ISOLATED - IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT)
› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)
oPtional inPuts/outPuts
— —
ingress Protection Ip 67 Ip 67
accuracy* Up TO 0.5% Up TO 0.5%
troubleshooting helP — —
maximum number of sPeed chords
2 chORDS 2 chORDS
models available STAnDARD / DUAL pIpE (IDEnTIcAL pROBES) / DUAL chORD STAnDARD / DUAL pIpE (IDEnTIcAL pROBES) / DUAL chORD
exPlosion-Proof(atex) enclosure
— AvAILABLE
1/2
* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.
Fixed flow meters for full pipe applications
Product name uf 811 uf 821 uf 831
nature of equiPment FIxED FLOW METER FIxED FLOW METER FIxED FLOW METER
media measured LIqUIDS LIqUIDS LIqUIDS
conditions of use pIpE UnDER LOAD pIpE UnDER LOAD pIpE UnDER LOAD
PiPe diameter Up TO 10000mm Up TO 10000mm Up TO 10000mm
standard mountedinPuts/outPuts
— — › 1 ISOLATED AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA
› 2 STATIc RELAy DIgITAL OUTpUTS (50v - 10mA) USABLE On FREqUEncy OUTpUTS
oPtional inPuts/outPuts
in oPtion, uP to 4 modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS (50v - 10mA) USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
in oPtion, uP to 4 modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS (50v - 10mA) USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
uP to 8 additional modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS (50v - 10mA) USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
ingress Protection Ip 67 Ip 67 Ip 67
accuracy* Up TO 0.5% Up TO 0.5% Up TO 0.5%
troubleshooting helP › OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn › qUALITy InDEx
› OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn › qUALITy InDEx
› OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn › qUALITy InDEx
maximum number of sPeed chords
2 chORDS 4 chORDS 8 chORDS
models available STAnDARD / DUAL pIpE / DUAL chORDcALORIMETER / DUAL cALORIMETER
SIngLE pIpE / MULTI-pIpE SIngLE pIpE / MULTI-pIpE
exPlosion-Proof(atex) enclosure
— AvAILABLE —
2/2
01. Flow measurement on big diameter GRP pipe02 & 03. Overspeed detection and flow measurement04 & 05. Multichords flow measurement for high precision
0201
03
04
05
* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.
Product name uf 811 co uf 821 co uf 831 co / uf 831 rv
nature of equiPment FIxED FLOW METER FIxED FLOW METER FIxED FLOW METER
media measured LIqUIDS LIqUIDS LIqUIDS
conditions of use FREE SURFAcE FLOW FREE SURFAcE FLOW FREE SURFAcE FLOW
channel / river width Up TO 30m (In cLEAn WATER) Up TO 30m (In cLEAn WATER) › chAnnELS Up TO 30m (WIDTh)
› RIvERS Up TO 500m (DISTAncE BETWEEn BAnkS)
standard mountedinPuts/outPuts
› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA
› 2 ISOLATED, pASSIvE cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA**
› 1 ISOLATED AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA
› 2 STATIc RELAy DIgITAL OUTpUTS (50v - 10mA) USABLE On FREqUEncy OUTpUTS
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA**
oPtional inPuts/outPuts
uP to 3 additional modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
uP to 3 additional modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
uP to 7 additional modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS - TAkIng Up ThE phySIcAL SpAcE OF 2 MODULES • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
ingress Protection Ip 67 Ip 67 Ip 67
accuracy* Up TO 0.5% Up TO 0.5% Up TO 0.5%
troubleshooting helP › OScILLOScOpE FUncTIOn (EchO DISpLAyED)
› gAIn
› qUALITy InDEx
› OScILLOScOpE FUncTIOn (EchO DISpLAyED)
› gAIn
› qUALITy InDEx
› OScILLOScOpE FUncTIOn (EchO DISpLAyED)
› gAIn
› qUALITy InDEx
maximum number of sPeed chords
2 chORDS 4 chORDS 8 chORDS
models available STAnDARD / DUAL chAnnELDUAL chORD
SIngLE chAnnELMULTI-chAnnEL / RIvER
SIngLE chAnnELMULTI-chAnnEL / RIvER
exPlosion-Proof(atex) enclosure
AvAILABLE
01. Flow measurement in partially filled pipes 02. Speed measurement on open channel 03 & 04. Flow measurement in natural rivers 05. Uf 831 CO in an electrical cabinet 06. Flow measurement in sewers 07. Flow measurement in river with 3 chords
02
03
06
01
04
07
05
Fixed flow meters for free surface flow applications
* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.
** MULTI-chAnnEL MODELS: 4 channels: 2 ISOLATED cURREnT InpUT MODULES 4-20mA, 0-20mA, 0-24mA (4 InpUTS) / 6 channels: 3 ISOLATED cURREnT InpUT MODULES 4-20mA, 0-20mA, 0-24mA (6 InpUTS) / 8 channels: 4 ISOLATED cURREnT InpUT MODULES 4-20mA, 0-20mA, 0-24mA (8 InpUTS).
Product name minisonic Psd minisonic isd
nature of equiPment pIg AnD SphERE DETEcTOR InTERFAcE, SphERE AnD pIg DETEcTOR
media measured LIqUIDS AnD gASES LIqUIDS AnD gASES
conditions of use pIpE UnDER LOAD pIpE UnDER LOAD
PiPe diameter FROM 100 TO 1500mm / FROM 4’’ TO 60’’ FROM 100 TO 1500mm / FROM 4’’ TO 60’’
standard mountedinPuts/outPuts
› 2 STATIc RELAy OUTpUTS › 2 AnALOgUE OUTpUTS › 2 STATIc RELAy OUTpUTS
oPtional inPuts/outPuts
— —
ingress Protection Ip 67 Ip 67
accuracy* Up TO 0.5% Up TO 0.5%
models available STAnDARD / pORTABLE STAnDARD / pORTABLE
exPlosion-Proof enclosure
AvAILABLE WITh STAnDARD MODEL AvAILABLE WITh STAnDARD MODEL
dedicated Probes(certification atex ex mb ii t6)
Sxn-M 1524 / Sxn-M 1698 / Sxn-ME 1691 / Sxn-ME 1679
Product name minisonic g uf 811 g uf 821 g
nature of equiPment FIxED FLOW METER FIxED FLOW METER FIxED FLOW METER
media measured gASES gASES gASES
conditions of use pIpE UnDER LOAD pIpE UnDER LOAD pIpE UnDER LOAD
PiPe diameter Up TO 1500mm Up TO 1500mm Up TO 1500mm
standard mountedinPuts/outPuts
› 2 cURREnT OUTpUTS, 4-20mA: gALvAnIcALLy ISOLATED, IMpEDAncE OF 1000Ω AS A pASSIvE OUTpUT AnD 150Ω AS An AcTIvE OUTpUT
› 2 STATIc RELAy OUTpUTS (100v - 100mA - 10vA MAx)
— —
oPtional inPuts/outPuts
— uP to 4 modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
uP to 4 modules to choose from:
› 1 ISOLATED, AcTIvE AnALOgUE OUTpUT: cURREnT 4-20mA, 0-20mA, 0-24mA • module 1
› 2 STATIc RELAy OUTpUTS USABLE AS FREqUEncy OUTpUTS (Up TO 1khz) • module 2
› 2 ISOLATED cURREnT InpUTS 4-20mA, 0-20mA, 0-24mA • module 3
› 2 ISOLATED, pASSIvE AnALOgUE 0-10v InpUTS: 0 TO 15v vOLTAgE • module 4
› 2 pT100/pT1000 TEMpERATURE InpUTS • module 5 (dual)
› 2 cOnTAcT 5v InpUTS (pULSE OR STATE) • module 6
ingress Protection Ip 67 Ip 67 Ip 67
accuracy* Up TO 0.5% Up TO 0.5% Up TO 0.5%
troubleshooting helP — › OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn› qUALITy InDEx
› OScILLOScOpE FUncTIOn (EchO DISpLAyED) › gAIn› qUALITy InDEx
maximum number of sPeed chords
2 chORDS 2 chORDS 4 chORDS
models available STAnDARD / DUAL pIpE / (IDEnTIcAL pROBES) / DUAL chORD
STAnDARD / DUAL pIpE / DUAL chORD SIngLE pIpE / MULTI-pIpE
exPlosion-Proof (atex) enclosure
AvAILABLE — AvAILABLE
01. Interface detection for oil products with clamp-on probes 02. Pig detection in gas pipeline with insertion probes 03. Sphere detection in liquid pipeline with insertion probes
* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.
* OnLy FOR InSTALLATIOnS ThAT RESpEcT pRODUcT AppLIcATIOn cOnDITIOnS. ThE AccURAcy OF ThE MEASUREMEnT ALSO DEpEnDS On ThE AccURAcy WITh WhIch ThE gEOMETRy OF ThE MEASURIng pOInT IS MEASURED, ThE DIMEn-SIOnS OF ThE pROBE pAIRS, ThE DISTAncE BETWEEn ThE pROBES AnD ThE LEngTh ThE WAvE hAS TO TRAvEL BETWEEn TWO pROBES. An InAccURAcy On OnE OF ThESE vALUES MAy cOMpROMISE ThE AccURAcy OF ThE MEASUREMEnT.
Fixed flow meter for gas application
Interface and scrapper detectors for full pipe applications
0201
030201
01. Uf 841 G gas flow meter with its stainless steel explosion-proof enclosure02. Spool piece 2 chords for gas flow measurement
Product name se 1714 se 1586 se 1662
PiPe diameter FROM 6 Up TO 20mm FROM 12 Up TO 115mm FROM 40 Up TO 1000mm
temPerature range -10°c TO +120°c -10°c TO +120°c -20°c TO +80°c
connectic pUSh-pULL pUSh-pULL pUSh-pULL / gLAnD cOnnEcTOR
frequency 4Mhz 2Mhz 500khz / 1Mhz
ingress Protection TypE Ip 67 TypE Ip 67 TypE Ip 67 / TypE Ip 68
dedicated suPPort IncLUDED IncLUDED SU-1707, SU-1517
atex version — — —
Product name se 1515 se 1595 se 1599
PiPe diameter FROM 40 Up TO 1000mm FROM 100 Up TO 2500mm FROM 100 Up TO 10000mm
temPerature range -20°c TO +180°c -20°c TO +80°c -20°c TO +120°c
connectic pUSh-pULL / gLAnD cOnnEcTOR pUSh-pULL / gLAnD cOnnEcTOR pUSh-pULL / gLAnD cOnnEcTOR
frequency 1Mhz 500khz 500khz
ingress Protection TypE Ip 67 / TypE Ip 68 TypE Ip 67 / TypE Ip 68 TypE Ip 67 / TypE Ip 68
dedicated suPPort SU-1707, SU-1517 SU-1735, SU-1629 SU-1735, SU-1629
atex version AvAILABLE (WITh gLAnD cOnnEcTOR OnLy) AvAILABLE (WITh gLAnD cOnnEcTOR OnLy) AvAILABLE (WITh gLAnD cOnnEcTOR OnLy)
Product name si 1614 si 1612 sxg 1708
aPPlication LIqUIDS LIqUIDS gAS
PiPe diameter FROM 80 Up TO 2000mm FROM 120 Up TO 4000mm FROM 80 Up TO 4000mm
temPerature range -10°c TO +60°c -10°c TO +60°c -10°c TO +60°c
connectic hEAD cOnnEcTOR hEAD cOnnEcTOR hEAD cOnnEcTOR
frequency 2Mhz / 3Mhz 1Mhz 250khz
ingress Protection TypE Ip 67 TypE Ip 67 TypE Ip 67
atex version — — yES (UnAvAILABLE In nOn-ATEx vERSIOn)
Product name sm 1690 sm 1689 sm 1684 sm 1681 sm 1666
aPPlication chAnnEL chAnnEL chAnnEL chAnnEL chAnnEL
distance between Probes FROM 3 Up TO 15m FROM 10 Up TO 30m FROM 30 Up TO 45m FROM 40 Up TO 80m FROM 70 Up TO 250m
temPerature range Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM
connectic gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR
frequency 500khz 200khz 200 / 250khz 200khz 200khz
ingress Protection TypE Ip 68 TypE Ip 68 TypE Ip 68 TypE Ip 68 TypE Ip 68
atex version — — — — —
Product name sm 1654 sm 1686 sm 1527 sm 1613
aPPlication chAnnEL chAnnEL chAnnEL chAnnEL
distance between Probes FROM 1 Up TO 4m FROM 2 Up TO 15m FROM 3 Up TO 15m FROM 3 Up TO 15m
temPerature range Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM Up TO 60°c MAxIMUM
connectic gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR gLAnD cOnnEcTOR
frequency 1Mhz 500khz 500khz 500khz
ingress Protection TypE Ip 68 TypE Ip 68 TypE Ip 68 TypE Ip 68
atex version — — AvAILABLE —
Ultraflux develops its own range of probes in order to perfectly suit with its converters. Our engineers create clamp-on, insertion and wetted probes. You will find below a few examples of them. This list is not exhaustive. For more information about all our available probes, please contact us.
Ultraflux probes
Clamp-on probes
Insertion probes
Wetted probes
Ultraflux transit-time flow measurement guidelines
Direct mode for intrusive probes
For a measurement with insertion probes, direct mode is used in most cases. However, reflex mode (V) may sometimes be used in specific conditions. Ultraflux determines the best solution depending on your application.
A settings window on Ultraflux PC software
A measurement window on Ultraflux PC software
Probes set-upsVarious possibilities for clamp-on probes
with clamp-on probes with insertion probes
c : sPeed of sound / vus
: velocity on the ultrasonic Path / Kh : hydraulic correction factor / q : flow / v : velocity / s : section
Measuring principle of ultrasonic transit time flow meters
mode reflex (or v) direct (or /) n w
Probes installation pROBES pLAcED On ThE SAME SIDE OF ThE pIpE, On A SAME gEnERATRIx - ThE ULTRASOnIc WAvE BEIng REFLEcTED OncE
pROBES pLAcED On BOTh SIDES OF ThE pIpE AnD ORIEnTED TOWARDS EAch OThER
pROBES pLAcED On BOTh SIDES OF ThE pIpE - ThE ULTRASOnIc WAvE BEIng REFLEcTED TWIcE
pROBES pLAcED On ThE SAME SIDE OF ThE pIpE, On A SAME gEnERATRIx - ThE ULTRASOnIc WAvE BEIng REFLEcTED ThRIcE
condition of use REcOMMAnDED In MOST cASES. AccURATE AnD EASy TO InSTALL
WhEn ThE pIpE cOnDITIOn DOES nOT ALLOW ThE USE OF REFLEx MODE. In cASE OF cORRODED pIpE, ABSORBEnT OR LOADED FLUID, MULTI-pRODUcT AppLIcATIOnS
pIpE DIAMETERS LESS ThAn 50 mm, LOW FLOW, gOOD InTERnAL pIpE cOnDITIOnS
pIpE DIAMETERS LESS ThAn 50 mm, LOW FLOW, gOOD InTERnAL pIpE cOnDITIOnS
Reflex (or V) mode Direct (or /) mode N and W mode
tab
= l / (c + vus
cos θ)
tba
= l / (c - vus
cos θ)
∆t = tba
– tab
v = Kh.vus
q = v.s
vus
=l2
tab
2d
∆t
tba
.
Our products can be configured from your PC or directly via the converter
Ultraflux PC software
Choice of operating mode
ultrafluxBâtiment Texas – Éragny Parc9 allée Rosa Luxemburg95610 Éragny sur Oise, FranceP. +33 (0)1 30 27 27 30F. +33 (0)1 30 39 84 34www.ultraflux.fr
ultraflux asia co ltd. 262-268 Worachak Road,Baanbart, Pomprab-sattrupai10100 Bangkok, ThailandP. +66 (0) 2621 1848F. +66 (0) 2621 1849www.ultraflux.com
ultraflux serviços e equipamentosRua do Livramento 125-1° AndarSaúde20221-192 Rio de Janeiro-RJ, BrazilP / F. +55 21 3575 3700consulta@use.com.brwww.use.com.br
Non contractual document
top related