think health. act now!. city of milwaukee health department. content in this presentation may not...
Post on 02-Jan-2016
213 Views
Preview:
TRANSCRIPT
Think Health. Act Now! . CITY OF MILWAUKEE HEALTH DEPARTMENT . www.milwaukee.gov/HealthContent in this presentation may not be duplicated, copied, or reproduced outside the purview of MHD without permission.
MHD Presentation TitleMHD Presentation TitleSubtext if ApplicableSubtext if Applicable
Presenter’s NamePresenter’s NamePresenter’s TitlePresenter’s Title
DateDate
Think Health. Act Now! . CITY OF MILWAUKEE HEALTH DEPARTMENT . www.milwaukee.gov/HealthContent in this presentation may not be duplicated, copied, or reproduced outside the purview of MHD without permission.
Think Health. Act Now! . CITY OF MILWAUKEE HEALTH DEPARTMENT . www.milwaukee.gov/HealthContent in this presentation may not be duplicated, copied, or reproduced outside the purview of MHD without permission.
Rapid Laboratory Tests: Rapid Laboratory Tests: Performance CharacteristicsPerformance Characteristics
TestTest SensitivitySensitivity SpecificitySpecificity
BinaxNOW Influenza A & BBinaxNOW Influenza A & B 100%(A); 93%(B)100%(A); 93%(B)22 96%(A); 97%(B)96%(A); 97%(B)22
BioStar OIA FLUBioStar OIA FLU 62-88% (A/B)62-88% (A/B) 52-80% (A/B)52-80% (A/B)
BioStar OIA FLU A/BBioStar OIA FLU A/B 62-88% (A/B)62-88% (A/B)11 52-80% (A/B)52-80% (A/B)11
Directigen Flu ADirectigen Flu A 91% (A)91% (A) 95% (A)95% (A)
Directigen Flu A+BDirectigen Flu A+B 86%(A); 81%(B) 86%(A); 81%(B) 91%(A); 99.5%(B) 91%(A); 99.5%(B)
Directigen EZ Flu A+BDirectigen EZ Flu A+B 77-86%(A); 81%(B) 77-86%(A); 81%(B) 69-80%(A);69-80%(A);
99-100%(B) 99-100%(B)
1= Equivalent to BioStar OIA FLU2= Compared to NOW Flu A & Flu B tests
Think Health. Act Now! . CITY OF MILWAUKEE HEALTH DEPARTMENT . www.milwaukee.gov/HealthContent in this presentation may not be duplicated, copied, or reproduced outside the purview of MHD without permission.
Rapid Laboratory Tests: Rapid Laboratory Tests: Performance CharacteristicsPerformance Characteristics
TestTest SensitivitySensitivity SpecificitySpecificity
Meridian TruFluMeridian TruFlu1185%-87%(A)85%-87%(A)
50%-64%(B)50%-64%(B)
89%-93%(A)89%-93%(A)
99%-100%(B)99%-100%(B)
OSOM Influenza A&BOSOM Influenza A&B 74%(A) 60%(B)74%(A) 60%(B) 96%(A) 96%(B)96%(A) 96%(B)
QuickVue InfluenzaQuickVue Influenza 73-81% (A/B)73-81% (A/B) 96-99% (A/B)96-99% (A/B)
QuickVue Influenza A+BQuickVue Influenza A+B 77-94%(A) 77-94%(A)
67-82%(B)67-82%(B)
89-99%(A);89-99%(A);
97-99%(B)97-99%(B)
SAS FluAlertSAS FluAlert 76%(A) 91%(B)76%(A) 91%(B) 98%(A); >99%(B)98%(A); >99%(B)
3M Rapid Detection Influenza 3M Rapid Detection Influenza A+BA+B11
80%(A)80%(A)
58-100%(B)58-100%(B)
94%-97%(A) 94%-97%(A)
98%-99%(B)98%-99%(B)
Xpect Flu A & BXpect Flu A & B 92%(A); 98%(B) 92%(A); 98%(B) 100%(A); 100%(B) 100%(A); 100%(B)
ZstatFluZstatFlu 58-65% (A/B) 58-65% (A/B) 98-100% (A/B) 98-100% (A/B)
1=Data from prospective study only included here
top related